| 3566074 | 129356 | None | code01 | A CIVIL WORKS Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & tacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.38 | 126.38 | 1189.0 | False | None | None | False | None | False | 150265.82 | 0 |
| 3566075 | 129356 | None | code02 | In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.76 | 449.76 | 5212.0 | False | None | None | False | None | False | 2344149.12 | 0 |
| 3566076 | 129356 | None | code03 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work
In Hard Rock (requiring blasting) Depth upto 1.50m | Cum | 686.41 | 686.41 | 341.0 | False | None | None | False | None | False | 234065.81 | 0 |
| 3566077 | 129356 | None | code04 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m | Cum | 299.84 | 299.84 | 6505.0 | False | None | None | False | None | False | 1950459.2 | 0 |
| 3566078 | 129356 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 11717.0 | False | None | None | False | None | False | 3861571.69 | 0 |
| 3566079 | 129356 | None | code06 | Earthwork excavation ( in deposited soil ) and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per pecifications.specification. | Cum | 587.29 | 587.29 | 134355.0 | False | None | None | False | None | False | 78905347.95 | 0 |
| 3566080 | 129356 | None | code07 | Construction of Granular Sub-Base by Mix in Place Method by providing well graded Gravel, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density complete as per Technical Spec | Cum | 2922.8 | 2922.8 | 3653.0 | False | None | None | False | None | False | 10676988.4 | 0 |
| 3566081 | 129356 | None | code08 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired densit | Cum | 3170.6 | 3170.6 | 940.0 | False | None | None | False | None | False | 2980364.0 | 0 |
| 3566082 | 129356 | None | code09 | Bituminous Macadam Grading - I for traffic less than 20 MSA Providing and laying Bituminous Macadam with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder VG 30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction | Cum | 9245.42 | 9245.42 | 376.0 | False | None | None | False | None | False | 3476277.92 | 0 |
| 3566083 | 129356 | None | code10 | Dense Graded Bituminous Macadam Grading - I for traffic less than20 MSA : Providing and laying Dense Graded Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading, premixed with bituminous binder VG-30, @ 4.0 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects. | Cum | 10972.58 | 10972.58 | 235.0 | False | None | None | False | None | False | 2578556.3 | 0 |
| 3566084 | 129356 | None | code11 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. | Cum | 12578.33 | 12578.33 | 235.0 | False | None | None | False | None | False | 2955907.55 | 0 |
| 3566085 | 129356 | None | code12 | Prime Coat over WMM/WBM : Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 kg per m2 using mechanical means. | Sqm | 65.67 | 65.67 | 4700.0 | False | None | None | False | None | False | 308649.0 | 0 |
| 3566086 | 129356 | None | code13 | Tack coat on Bituminous surface : Providing and applying tack coat with VG-10 Bitumen using pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom | Sqm | 14.87 | 14.87 | 4700.0 | False | None | None | False | None | False | 69889.0 | 0 |
| 3566087 | 129356 | None | code14 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately) Mix 1:4:8(M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7017.7 | 7017.7 | 722.0 | False | None | None | False | None | False | 5066779.4 | 0 |
| 3566088 | 129356 | None | code15 | Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 106.0 | False | None | None | False | None | False | 786559.22 | 0 |
| 3566089 | 129356 | None | code16 | Providing and laying in position Reinforced/ Plain cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately)
Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates
0.00m to 3.60m Level | Cum | 8569.32 | 8569.32 | 83.0 | False | None | None | False | None | False | 711253.56 | 0 |
| 3566090 | 129356 | None | code17 | Above 3.60m to 6.60m Level | Cum | 8655.01 | 8655.01 | 6.0 | False | None | None | False | None | False | 51930.06 | 0 |
| 3566091 | 129356 | None | code18 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.
M20 mm nominal size graded crushed coarse aggregates (including cost of formwork) | Cum | 10576.17 | 10576.17 | 1226.0 | False | None | None | False | None | False | 12966384.42 | 0 |
| 3566092 | 129356 | None | code19 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
'--do-- for Column Footings / Retaining Wall Footings / Raft / Base Slab | Cum | 8412.76 | 8412.76 | 435.0 | False | None | None | False | None | False | 3659550.6 | 0 |
| 3566093 | 129356 | None | code20 | M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
'--do-- for Column Footings / Retaining Wall Footings / Raft / Base Slab | Cum | 8478.33 | 8478.33 | 545.0 | False | None | None | False | None | False | 4620689.85 | 0 |
| 3566094 | 129356 | None | code21 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately)
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
--do-- for Plinth Beam with M-25 | Cum | 12043.08 | 12043.08 | 60.0 | False | None | None | False | None | False | 722584.8 | 0 |
| 3566095 | 129356 | None | code22 | do-- for RCC Wall with M-25 | Cum | 10838.77 | 10838.77 | 1354.0 | False | None | None | False | None | False | 14675694.58 | 0 |
| 3566096 | 129356 | None | code23 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately)
M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
For RCC Raft | Cum | 8696.44 | 8696.44 | 48.0 | False | None | None | False | None | False | 417429.12 | 0 |
| 3566097 | 129356 | None | code24 | do-- for RCC Wall with M-30 | Cum | 11047.85 | 11047.85 | 41.0 | False | None | None | False | None | False | 452961.85 | 0 |
| 3566098 | 129356 | None | code25 | do-- for RCC Slab with M-30 | Cum | 13022.51 | 13022.51 | 82.0 | False | None | None | False | None | False | 1067845.82 | 0 |
| 3566099 | 129356 | None | code26 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately)
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
'--do-- for Columns / Pedestals with M-25.
0.00m to 3.60m Level | Cum | 14413.41 | 14413.41 | 207.0 | False | None | None | False | None | False | 2983575.87 | 0 |
| 3566100 | 129356 | None | code27 | Above 3.60m to 6.60m Level | Cum | 14557.55 | 14557.55 | 38.0 | False | None | None | False | None | False | 553186.9 | 0 |
| 3566101 | 129356 | None | code28 | do-- for Lintel / Tie Beam with M-25
0.00m to 3.60m Level | Cum | 13565.56 | 13565.56 | 31.0 | False | None | None | False | None | False | 420532.36 | 0 |
| 3566102 | 129356 | None | code29 | Above 3.60m to 6.60m Level | Cum | 13701.22 | 13701.22 | 18.0 | False | None | None | False | None | False | 246621.96 | 0 |
| 3566103 | 129356 | None | code30 | do-- for Staircase with M-25
0.00m to 3.60m Level | Cum | 12717.72 | 12717.72 | 7.0 | False | None | None | False | None | False | 89024.04 | 0 |
| 3566104 | 129356 | None | code31 | Above 3.60m to 6.60m Level | Cum | 12844.89 | 12844.89 | 4.0 | False | None | None | False | None | False | 51379.56 | 0 |
| 3566105 | 129356 | None | code32 | do-- for Roof Beams with M-25
0.00m to 3.60m Level | Cum | 13565.56 | 13565.56 | 118.0 | False | None | None | False | None | False | 1600736.08 | 0 |
| 3566106 | 129356 | None | code33 | Above 3.60m to 6.60m Level | Cum | 13701.22 | 13701.22 | 84.0 | False | None | None | False | None | False | 1150902.48 | 0 |
| 3566107 | 129356 | None | code34 | do-- for Roof Slabs with M-25
0.00m to 3.60m Level | Cum | 12717.72 | 12717.72 | 209.0 | False | None | None | False | None | False | 2658003.48 | 0 |
| 3566108 | 129356 | None | code35 | Above 3.60m to 6.60m Level | Cum | 12844.89 | 12844.89 | 201.0 | False | None | None | False | None | False | 2581822.89 | 0 |
| 3566109 | 129356 | None | code36 | do-- for Chejja with M-25.
0.00m to 3.60m Level | Cum | 12293.79 | 12293.79 | 4.0 | False | None | None | False | None | False | 49175.16 | 0 |
| 3566110 | 129356 | None | code37 | Above 3.60m to 6.60m Level | Cum | 12416.73 | 12416.73 | 2.0 | False | None | None | False | None | False | 24833.46 | 0 |
| 3566111 | 129356 | None | code38 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications.
0.00m to 3.60m Level | Sqm | 1533.88 | 1533.88 | 72.0 | False | None | None | False | None | False | 110439.36 | 0 |
| 3566112 | 129356 | None | code39 | Above 3.60m to 6.60m Level | Sqm | 1549.22 | 1549.22 | 71.0 | False | None | None | False | None | False | 109994.62 | 0 |
| 3566113 | 129356 | None | code40 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) 0.00m to 3.60m Level | MT | 110837.22 | 110837.22 | 327.0 | False | None | None | False | None | False | 36243770.94 | 0 |
| 3566114 | 129356 | None | code41 | Above 3.60m to 6.60m Level | MT | 111945.6 | 111945.6 | 44.0 | False | None | None | False | None | False | 4925606.4 | 0 |
| 3566115 | 129356 | None | code42 | Above 36.60m to 39.60m Level | MT | 124137.69 | 124137.69 | 2.0 | False | None | None | False | None | False | 248275.38 | 0 |
| 3566116 | 129356 | None | code43 | Providing and constructing granite / trap / basalt size stone masonry with hard stone in foundation & plinth in cement mortar 1:6, stones in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. | Cum | 7915.97 | 7915.97 | 180.0 | False | None | None | False | None | False | 1424874.6 | 0 |
| 3566117 | 129356 | None | code44 | Providing and constructing Brick work ( 230mm thk ) with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
0.00m to 3.60m Level | Cum | 9873.59 | 9873.59 | 58.0 | False | None | None | False | None | False | 572668.22 | 0 |
| 3566118 | 129356 | None | code45 | Above 3.60m to 6.60m Level | Cum | 9972.33 | 9972.33 | 44.0 | False | None | None | False | None | False | 438782.52 | 0 |
| 3566119 | 129356 | None | code46 | Providing and constructing Half brick masonry ( 115mm thk ) with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. including providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
0.00m to 3.60m Level | Sqm | 1397.59 | 1397.59 | 57.0 | False | None | None | False | None | False | 79662.63 | 0 |
| 3566120 | 129356 | None | code47 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
0.00m to 3.60m Level | Sqm | 1623.09 | 1623.09 | 1404.0 | False | None | None | False | None | False | 2278818.36 | 0 |
| 3566121 | 129356 | None | code48 | Above 3.60m to 6.60m Level | Sqm | 1639.32 | 1639.32 | 727.0 | False | None | None | False | None | False | 1191785.64 | 0 |
| 3566122 | 129356 | None | code49 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of allmaterials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
0.00m to 3.60m Level | Sqm | 1367.86 | 1367.86 | 95.0 | False | None | None | False | None | False | 129946.7 | 0 |
| 3566123 | 129356 | None | code50 | Above 3.60m to 6.60m Level | Sqm | 1381.53 | 1381.53 | 186.0 | False | None | None | False | None | False | 256964.58 | 0 |
| 3566124 | 129356 | None | code51 | Providing and Fixing special Stainless Steel Doors (Flush Type) (Shakti Met-Dor Type) including installation, fixtures, hardware complete as per approved specifications, drawings and as directed. The door frame made of 100x75x1.2mm thk and Shutter of 30mm thk made of 0.80mm thk SS 304 Sheet with hairline / suitable finish. The Shutter to be double skin with suitable in fill for strength. The door shall be complete with all necessary accessories like SS Hinges, Locks, SS Hnadles, Vision Panle of 350x750mm size approx., Tower Bolts.
0.00m to 3.60m Level | Sqm | 24151.83 | 24151.83 | 36.0 | False | None | None | False | None | False | 869465.88 | 0 |
| 3566125 | 129356 | None | code52 | Above 3.60m to 6.60m Level | Sqm | 24393.35 | 24393.35 | 42.0 | False | None | None | False | None | False | 1024520.7 | 0 |
| 3566126 | 129356 | None | code53 | Above 6.60m to 9.60m Level | Sqm | 24634.86 | 24634.86 | 11.0 | False | None | None | False | None | False | 270983.46 | 0 |
| 3566127 | 129356 | None | code54 | Above 9.60m to 12.60m Level | Sqm | 24876.38 | 24876.38 | 23.0 | False | None | None | False | None | False | 572156.74 | 0 |
| 3566128 | 129356 | None | code55 | Above 12.60m to 15.60m Level | Sqm | 25117.9 | 25117.9 | 5.0 | False | None | None | False | None | False | 125589.5 | 0 |
| 3566129 | 129356 | None | code56 | Above 15.60m to 18.60m Level | Sqm | 25359.42 | 25359.42 | 32.0 | False | None | None | False | None | False | 811501.44 | 0 |
| 3566130 | 129356 | None | code57 | Above 24.60m to 27.60m Level | Sqm | 26083.97 | 26083.97 | 12.0 | False | None | None | False | None | False | 313007.64 | 0 |
| 3566131 | 129356 | None | code58 | Above 30.60m to 33.60m Level | Sqm | 26567.0 | 26567.0 | 6.0 | False | None | None | False | None | False | 159402.0 | 0 |
| 3566132 | 129356 | None | code59 | Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.
0.00m to 3.60m Level | Cum | 291969.11 | 291969.11 | 0.15 | False | None | None | False | None | False | 43795.3665 | 0 |
| 3566133 | 129356 | None | code60 | Above 3.60m to 6.60m Level | Cum | 294888.8 | 294888.8 | 0.39 | False | None | None | False | None | False | 115006.632 | 0 |
| 3566134 | 129356 | None | code61 | Providing and fixing in position fully panelled Teak wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (including cost of fixtures)
0.00m to 3.60m Level | Sqm | 13423.33 | 13423.33 | 8.0 | False | None | None | False | None | False | 107386.64 | 0 |
| 3566135 | 129356 | None | code62 | Above 3.60m to 6.60m Level | Sqm | 13557.56 | 13557.56 | 23.0 | False | None | None | False | None | False | 311823.88 | 0 |
| 3566136 | 129356 | None | code63 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge.
Size 62 x 125mm
0.00m to 3.60m Level | m | 946.6 | 946.6 | 0.5 | False | None | None | False | None | False | 473.3 | 0 |
| 3566137 | 129356 | None | code64 | Above 3.60m to 6.60m Level | m | 956.06 | 956.06 | 0.27 | False | None | None | False | None | False | 258.1362 | 0 |
| 3566138 | 129356 | None | code65 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquidphenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. (Including Cost of All Fixtures)
-do- 35 mm thick both side Teak
0.00m to 3.60m Level | Sqm | 7473.65 | 7473.65 | 23.0 | False | None | None | False | None | False | 171893.95 | 0 |
| 3566139 | 129356 | None | code66 | Above 3.60m to 6.60m Level | Sqm | 7548.38 | 7548.38 | 13.0 | False | None | None | False | None | False | 98128.94 | 0 |
| 3566140 | 129356 | None | code67 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
0.00m to 3.60m Level | m | 394.0 | 394.0 | 56.0 | False | None | None | False | None | False | 22064.0 | 0 |
| 3566141 | 129356 | None | code68 | Above 3.60m to 6.60m Level | m | 397.94 | 397.94 | 46.0 | False | None | None | False | None | False | 18305.24 | 0 |
| 3566142 | 129356 | None | code69 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. (Including Cost of All Fixtures)
-do- with both side prelam :
0.00m to 3.60m Level | Sqm | 3550.97 | 3550.97 | 17.0 | False | None | None | False | None | False | 60366.49 | 0 |
| 3566143 | 129356 | None | code70 | Above 3.60m to 6.60m Level | Sqm | 3586.48 | 3586.48 | 14.0 | False | None | None | False | None | False | 50210.72 | 0 |
| 3566144 | 129356 | None | code71 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. 0.00m to 3.60m Level | Kgs | 707.47 | 707.47 | 2335.0 | False | None | None | False | None | False | 1651942.45 | 0 |
| 3566145 | 129356 | None | code72 | Above 3.60m to 6.60m Level | Kgs | 714.54 | 714.54 | 639.0 | False | None | None | False | None | False | 456591.06 | 0 |
| 3566146 | 129356 | None | code73 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5mm thickness (weight not less than 12.50kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
0.00m to 3.60m Level | Sqm | 1450.87 | 1450.87 | 252.0 | False | None | None | False | None | False | 365619.24 | 0 |
| 3566147 | 129356 | None | code74 | Above 3.60m to 6.60m Level | Sqm | 1465.38 | 1465.38 | 42.0 | False | None | None | False | None | False | 61545.96 | 0 |
| 3566148 | 129356 | None | code75 | Providing & fixing SS fly proof wire gauze to windows, clerestory windows & doors to exsisting aluminium frame. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
0.00m to 3.60m Level | Sqm | 1068.02 | 1068.02 | 81.0 | False | None | None | False | None | False | 86509.62 | 0 |
| 3566149 | 129356 | None | code76 | Above 3.60m to 6.60m Level | Sqm | 1078.7 | 1078.7 | 39.0 | False | None | None | False | None | False | 42069.3 | 0 |
| 3566150 | 129356 | None | code77 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding / Aluminium Windows with Holdfast embeded in masonry
0.00m to 3.60m Level | Kgs | 208.15 | 208.15 | 2696.0 | False | None | None | False | None | False | 561172.4 | 0 |
| 3566151 | 129356 | None | code78 | Above 3.60m to 6.60m Level | Kgs | 210.23 | 210.23 | 871.0 | False | None | None | False | None | False | 183110.33 | 0 |
| 3566152 | 129356 | None | code79 | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners, stainlesssteel bolts etc., of required size, on the top of the floor or the side of waistslab with suitable arrangement as per approval of Engineer-in- charge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery completeas per specifications and as per directions of the Engineer-in-Charge.
0.00m to 3.60m Level | Kgs | 700.04 | 700.04 | 112.0 | False | None | None | False | None | False | 78404.48 | 0 |
| 3566153 | 129356 | None | code80 | Above 3.60m to 6.60m Level | Kgs | 707.04 | 707.04 | 112.0 | False | None | None | False | None | False | 79188.48 | 0 |
| 3566154 | 129356 | None | code81 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linearas well as curvilinear portions of the building by providing semi -rigid,inorganic, non-combustible fibre glass wool insulation 50 mm thick, conformingto IS: 8183 and BS: 3958 Part 5. The insulation layer shall havefacing (factory bonded on surface 1 of the fibre glass insulation layer),of black non-woven fibre glass tissue of nominal thickness 0.5 mm andnominal mass not less than60 g/m2,made of randomly oriented glassfibres distributed in a binder by a wet-lay process including fixing 1.5mm thick solid aluminum sheet backing using, 6 mm thick cement boardincluding SS rivets, nuts, bolts, washers etc complete.
0.00m to 3.60m Level | Sqm | 2402.42 | 2402.42 | 20.0 | False | None | None | False | None | False | 48048.4 | 0 |
| 3566155 | 129356 | None | code82 | Above 3.60m to 6.60m Level | Sqm | 2426.45 | 2426.45 | 113.0 | False | None | None | False | None | False | 274188.85 | 0 |
| 3566156 | 129356 | None | code83 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary
For Straight Portion
0.00m to 3.60m Level | Sqm | 4942.37 | 4942.37 | 41.0 | False | None | None | False | None | False | 202637.17 | 0 |
| 3566157 | 129356 | None | code84 | Above 3.60m to 6.60m Level | Sqm | 4991.79 | 4991.79 | 107.0 | False | None | None | False | None | False | 534121.53 | 0 |
| 3566158 | 129356 | None | code85 | Providing, fabricating and fixing of 6 mm thick High Pressure Laminate sheets in standard size of 1200 mm x 2400 mm (Sheets can be supplied in customized length depending on requirement). Sheets shall be manufactured involving a series of mechanical process in a state-of-the-art facility shall comprise of 0.25 mm Aluminium skins on both sides sandwiching an LDPE (Low Density Poly Ethylene) core having a density of 0.92 g/cm3 giving the overall weight of HPL at 7.8 kg/m2. Aluminium skins to have a desired lacquer in Lumiflon coated on one side/Both side. The supplied panels shall have a dexterity to be formed in convex and concave shapes as also the ability to bend in 90 degrees under a mechanical process. Panel will be installed on Aluminium tubes at 500 mm c/c distance with special L brackets. There will be special fixing treatment on all the corner sections. Aluminium tube size will be 25 mm x 50 mm. Boards will be fixed on the Aluminium channels with colour matched rivets/ MS polymer Adhesives and brackets through 8 mm drill hole in boards and 5 mm dia drill holes in aluminium box. Rivets will be installed by automatic rivet guns / adhesive should be used with proper silicone extrusion gun and properly laid over panel and aluminium tube on every 500mm gap as per direction of Engineer in charge.
Wooden textured Colored sheets-Double sided
0.00m to 3.60m Level | Sqm | 4511.2 | 4511.2 | 56.0 | False | None | None | False | None | False | 252627.2 | 0 |
| 3566159 | 129356 | None | code86 | Above 3.60m to 6.60m Level | Sqm | 4556.31 | 4556.31 | 173.0 | False | None | None | False | None | False | 788241.63 | 0 |
| 3566160 | 129356 | None | code87 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to Ceiling / Concrete / brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 400.2 | 400.2 | 1715.0 | False | None | None | False | None | False | 686343.0 | 0 |
| 3566161 | 129356 | None | code88 | Above 3.60m to 6.60m Level | Sqm | 404.2 | 404.2 | 1654.0 | False | None | None | False | None | False | 668546.8 | 0 |
| 3566162 | 129356 | None | code89 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 432.41 | 432.41 | 2061.0 | False | None | None | False | None | False | 891197.01 | 0 |
| 3566163 | 129356 | None | code90 | Above 3.60m to 6.60m Level | Sqm | 436.74 | 436.74 | 971.0 | False | None | None | False | None | False | 424074.54 | 0 |
| 3566164 | 129356 | None | code91 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 477.02 | 477.02 | 1555.0 | False | None | None | False | None | False | 741766.1 | 0 |
| 3566165 | 129356 | None | code92 | Above 3.60m to 6.60m Level | Sqm | 481.79 | 481.79 | 1240.0 | False | None | None | False | None | False | 597419.6 | 0 |
| 3566166 | 129356 | None | code93 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer- in-Charge.
0.00m to 3.60m Level | Sqm | 551.36 | 551.36 | 530.0 | False | None | None | False | None | False | 292220.8 | 0 |
| 3566167 | 129356 | None | code94 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.
0.00m to 3.60m Level | m | 81.77 | 81.77 | 783.0 | False | None | None | False | None | False | 64025.91 | 0 |
| 3566168 | 129356 | None | code95 | Above 3.60m to 6.60m Level | m | 82.59 | 82.59 | 396.0 | False | None | None | False | None | False | 32705.64 | 0 |
| 3566169 | 129356 | None | code96 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.
0.00m to 3.60m Level | Sqm | 3533.63 | 3533.63 | 20.72 | False | None | None | False | None | False | 73216.8136 | 0 |
| 3566170 | 129356 | None | code97 | Providing and laying flamed / Sand Blasted finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 30 mm thick stone slab over 25 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.
0.00m to 3.60m Level | Sqm | 4124.75 | 4124.75 | 116.0 | False | None | None | False | None | False | 478471.0 | 0 |
| 3566171 | 129356 | None | code98 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2
0.00m to 3.60m Level | Sqm | 4877.94 | 4877.94 | 19.0 | False | None | None | False | None | False | 92680.86 | 0 |
| 3566172 | 129356 | None | code99 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.
0.00m to 3.60m Level | Sqm | 6601.39 | 6601.39 | 308.0 | False | None | None | False | None | False | 2033228.12 | 0 |
| 3566173 | 129356 | None | code100 | Above 3.60m to 6.60m Level | Sqm | 6667.41 | 6667.41 | 21.0 | False | None | None | False | None | False | 140015.61 | 0 |
| 3566174 | 129356 | None | code101 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.
0.00m to 3.60m Level | m | 406.39 | 406.39 | 303.0 | False | None | None | False | None | False | 123136.17 | 0 |
| 3566175 | 129356 | None | code102 | Above 3.60m to 6.60m Level | m | 410.46 | 410.46 | 36.0 | False | None | None | False | None | False | 14776.56 | 0 |
| 3566176 | 129356 | None | code103 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.
0.00m to 3.60m Level | Sqm | 4161.8 | 4161.8 | 288.0 | False | None | None | False | None | False | 1198598.4 | 0 |
| 3566177 | 129356 | None | code104 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
0.00m to 3.60m Level | Sqm | 1418.66 | 1418.66 | 978.0 | False | None | None | False | None | False | 1387449.48 | 0 |
| 3566178 | 129356 | None | code105 | Above 3.60m to 6.60m Level | Sqm | 1432.84 | 1432.84 | 900.0 | False | None | None | False | None | False | 1289556.0 | 0 |
| 3566179 | 129356 | None | code106 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting / dadoing, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge
0.00m to 3.60m Level | Sqm | 1890.71 | 1890.71 | 330.0 | False | None | None | False | None | False | 623934.3 | 0 |
| 3566180 | 129356 | None | code107 | Above 3.60m to 6.60m Level | Sqm | 1909.62 | 1909.62 | 41.0 | False | None | None | False | None | False | 78294.42 | 0 |
| 3566181 | 129356 | None | code108 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
0.00m to 3.60m Level | Sqm | 1370.33 | 1370.33 | 22.0 | False | None | None | False | None | False | 30147.26 | 0 |
| 3566182 | 129356 | None | code109 | Above 3.60m to 6.60m Level | Sqm | 1384.04 | 1384.04 | 49.0 | False | None | None | False | None | False | 67817.96 | 0 |
| 3566183 | 129356 | None | code110 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.
0.00m to 3.60m Level | Sqm | 1370.33 | 1370.33 | 100.0 | False | None | None | False | None | False | 137033.0 | 0 |
| 3566184 | 129356 | None | code111 | Above 3.60m to 6.60m Level | Sqm | 1384.04 | 1384.04 | 48.0 | False | None | None | False | None | False | 66433.92 | 0 |
| 3566185 | 129356 | None | code112 | Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification.
0.00m to 3.60m Level | Sqm | 2698.54 | 2698.54 | 225.0 | False | None | None | False | None | False | 607171.5 | 0 |
| 3566186 | 129356 | None | code113 | Providing and constructing VDF Flooring, with cement concrete pavement, 150mm Thick, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including leveling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and including placing the concrete in panels, extracting excess water from concrete & polishing to the required smoothness, adding approved floor hardeners (7Kg/Sqm Nitofloor or equivalent approved make), providing expansion joints in the form of 6X20mm groove cutting, filling with approved ceiling compound at 3X3m intervals, providing steel reinforcements (excluding cost of steel bars & fabrication charges), hire charges of plant & machinery etc. complete. as per technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.
0.00m to 3.60m Level | Sqm | 1827.53 | 1827.53 | 3795.0 | False | None | None | False | None | False | 6935476.35 | 0 |
| 3566187 | 129356 | None | code114 | do -- VDF Flooring - 100mm Thick - M20 (Grade)
Above 3.60m to 6.60m Level | Sqm | 1447.86 | 1447.86 | 429.0 | False | None | None | False | None | False | 621131.94 | 0 |
| 3566188 | 129356 | None | code115 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick olythene film, wedges, steel plates including levelling the ormwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 8368.21 | 8368.21 | 3738.0 | False | None | None | False | None | False | 31280368.98 | 0 |
| 3566189 | 129356 | None | code116 | Providing and fixing in position 32 mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 600 mm. Long and at 300 mm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. | Nos | 594.72 | 594.72 | 3405.0 | False | None | None | False | None | False | 2025021.6 | 0 |
| 3566190 | 129356 | None | code117 | Providing and fixing in position, tie bars precoated with anticorrosive epoxy paint of 12 mm dia. 700 mm. long and at 300 mm. C/C and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of TMT, chairs with proper alignment etc. complete. No. 270.00 4 MoRTH 602.6.3 | Nos | 334.53 | 334.53 | 13620.0 | False | None | None | False | None | False | 4556298.6 | 0 |
| 3566191 | 129356 | None | code118 | Vaccum de-watering with vaccum pump and suction mat and compaction with skin floater clubbed with floating disc including cost of generator, HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., with all lead and lift with laser levelling | Sqm | 105.32 | 105.32 | 14950.0 | False | None | None | False | None | False | 1574534.0 | 0 |
| 3566192 | 129356 | None | code119 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge | m | 86.73 | 86.73 | 11237.0 | False | None | None | False | None | False | 974585.01 | 0 |
| 3566193 | 129356 | None | code120 | Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (approx. 25% larger than the initial 3 mm.to 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide). | m | 204.44 | 204.44 | 11237.0 | False | None | None | False | None | False | 2297292.28 | 0 |
| 3566194 | 129356 | None | code121 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)
Medium shade pigment using 50% white cement 50% Grey cement | Sqm | 1476.89 | 1476.89 | 1012.0 | False | None | None | False | None | False | 1494612.68 | 0 |
| 3566195 | 129356 | None | code122 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
0.00m to 3.60m Level | Sqm | 123.9 | 123.9 | 3022.0 | False | None | None | False | None | False | 374425.8 | 0 |
| 3566196 | 129356 | None | code123 | Above 3.60m to 6.60m Level | Sqm | 125.14 | 125.14 | 2536.0 | False | None | None | False | None | False | 317355.04 | 0 |
| 3566197 | 129356 | None | code124 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 195.76 | 195.76 | 3246.0 | False | None | None | False | None | False | 635436.96 | 0 |
| 3566198 | 129356 | None | code125 | Above 3.60m to 6.60m Level | Sqm | 197.72 | 197.72 | 2536.0 | False | None | None | False | None | False | 501417.92 | 0 |
| 3566199 | 129356 | None | code126 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 193.28 | 193.28 | 583.0 | False | None | None | False | None | False | 112682.24 | 0 |
| 3566200 | 129356 | None | code127 | Above 3.60m to 6.60m Level | Sqm | 195.22 | 195.22 | 778.0 | False | None | None | False | None | False | 151881.16 | 0 |
| 3566201 | 129356 | None | code128 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 350.64 | 350.64 | 620.0 | False | None | None | False | None | False | 217396.8 | 0 |
| 3566202 | 129356 | None | code129 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 170.98 | 170.98 | 3058.0 | False | None | None | False | None | False | 522856.84 | 0 |
| 3566203 | 129356 | None | code130 | Above 3.60m to 6.60m Level | Sqm | 172.69 | 172.69 | 33.0 | False | None | None | False | None | False | 5698.77 | 0 |
| 3566204 | 129356 | None | code131 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.60m Level | Sqm | 172.22 | 172.22 | 3186.0 | False | None | None | False | None | False | 548692.92 | 0 |
| 3566205 | 129356 | None | code132 | Above 3.60m to 6.60m Level | Sqm | 173.94 | 173.94 | 21.0 | False | None | None | False | None | False | 3652.74 | 0 |
| 3566206 | 129356 | None | code133 | French spirit polishing :Two coats on new works including a coat of wood filler to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
0.00m to 3.60m Level | Sqm | 365.51 | 365.51 | 20.0 | False | None | None | False | None | False | 7310.2 | 0 |
| 3566207 | 129356 | None | code134 | Above 3.60m to 6.60m Level | Sqm | 369.16 | 369.16 | 58.0 | False | None | None | False | None | False | 21411.28 | 0 |
| 3566208 | 129356 | None | code135 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
0.00m to 3.60m Level | m | 703.75 | 703.75 | 99.0 | False | None | None | False | None | False | 69671.25 | 0 |
| 3566209 | 129356 | None | code136 | Above 3.60m to 6.60m Level | m | 710.79 | 710.79 | 75.0 | False | None | None | False | None | False | 53309.25 | 0 |
| 3566210 | 129356 | None | code137 | Providing and injecting chemical emulsion for Preconstructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits, with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to one percent concentration, labour, HOM of equipments, complete as per specifications. (Plinth area of the building at ground floor only shall be measured ) | Sqm | 146.2 | 146.2 | 1300.0 | False | None | None | False | None | False | 190060.0 | 0 |
| 3566211 | 129356 | None | code138 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge. | Cum | 8259.17 | 8259.17 | 2243.0 | False | None | None | False | None | False | 18525318.31 | 0 |
| 3566212 | 129356 | None | code139 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA& for Residential Streets of approved shape and colour, laid inrequired pattern and including over 40mm thick compacted bedof coarse sand, filling the joints with fine sand etc. all complete asper the direction of Engineer-in-charge. (WMM/WBM Base to bepaid separately as per relevant technical specification) | Sqm | 1438.48 | 1438.48 | 717.0 | False | None | None | False | None | False | 1031390.16 | 0 |
| 3566213 | 129356 | None | code140 | Providing and laying integral cement based waterproofing treatment iincluding preparation of surface as requried for treatment of roofs, balconies, terrace etc., consisting of following application. (a)Applying ang grouting a slurry coat of neat cement using 2.75kg/sqm of cement admixed with properly water proofing compound conforming to IS:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5 admixed with proprietary water proffing compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement slurry admixed with proprietary water proofing compound. (D) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications.
0.00m to 3.60m Level | Sqm | 2087.22 | 2087.22 | 526.0 | False | None | None | False | None | False | 1097877.72 | 0 |
| 3566214 | 129356 | None | code141 | Above 3.60m to 6.60m Level | Sqm | 2108.09 | 2108.09 | 1160.0 | False | None | None | False | None | False | 2445384.4 | 0 |
| 3566215 | 129356 | None | code142 | Pre-Engineering Structure
Providing & fixing All Primary steel (At Any Level / Hight) including Rafters, Columns shall be Built up Sections made out of plates having a minimum yield strength of 345 Mpa. Grade 50 conforming to ASTM A 572 including providing & painting 2 coats of anticorrisive paint in apporved shade over a coat of primer & patti work. | MT | 168008.4 | 168008.4 | 257.0 | False | None | None | False | None | False | 43178158.8 | 0 |
| 3566216 | 129356 | None | code143 | Providing & fixing All M.S.Secondry structural (At Any Level / Hight) Frame including Purlins, Girts shall be made out Cold Formed steel of min yield strength of 250 Mpa including providing & painting 2 coats of anticorrisive paint in apporved shade over a coat of primer & patti work. | MT | 168008.4 | 168008.4 | 54.0 | False | None | None | False | None | False | 9072453.6 | 0 |
| 3566217 | 129356 | None | code144 | Providing & fixing High tension foundation Bolts & nuts (At Any Level / Hight) of various sizes having a minimum yield strength of 800 Mpa. at column bases, excluding cost of concrete including providing & painting 2 coats of anticorrisive paint in apporved shade over a coat of primer & patti work, fixing to be done by civil contractor under the supervision of PEB vendor representative. | Kgs | 170.36 | 170.36 | 15.0 | False | None | None | False | None | False | 2555.4 | 0 |
| 3566218 | 129356 | None | code145 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.
0.00m to 3.60m Level | Kgs | 140.01 | 140.01 | 6190.0 | False | None | None | False | None | False | 866661.9 | 0 |
| 3566219 | 129356 | None | code146 | Providing and fixing Steel work in built up tubular trusses (round, square or rectangular hollow tubes etc.) etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications andas per directions of the Engineer-in-Charge. For Truss / Gate & other structural steel works etc...
0.00m to 3.60m Level | Kgs | 182.13 | 182.13 | 1300.0 | False | None | None | False | None | False | 236769.0 | 0 |
| 3566220 | 129356 | None | code147 | Providing and Grouting the foundation bolts/pockets, base plates (for any level / hight) with ACC Shrink komp grade-2/ GP2 of FOSROC or FLOWGROUT 60 of FAIRMATE ready mixed non shrink, free flow, self leveling, cementitious grout making holes if necessary in concrete, curing etc. as per the recommendations of the manufacturer, complete as directed. 50 to 60mm (Max) thick. | Sqm | 4646.25 | 4646.25 | 29.0 | False | None | None | False | None | False | 134741.25 | 0 |
| 3566221 | 129356 | None | code148 | P/F 1.2mm thick G.I. Decking sheets from approved make with crest depth of 52mm made out of high tensiled, structural grade galvanised steel (240MPa yeild strength) sheet for floor including all accessories for fixing in to the structural members, edge stoper etc complete.Above 36.60m to 39.60m Level | Sqm | 1936.65 | 1936.65 | 150.0 | False | None | None | False | None | False | 290497.5 | 0 |
| 3566222 | 129356 | None | code149 | Providing & laying RCC Deck Slab using M25 grade concrete excluding cost of deck sheets & steel reinforcements including smooth finish on top as per specification.
Above 36.60m to 39.60m Level | Cum | 9495.89 | 9495.89 | 23.0 | False | None | None | False | None | False | 218405.47 | 0 |
| 3566223 | 129356 | None | code150 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Roofing
Above 6.60m to 9.60m Level | Sqm | 717.83 | 717.83 | 555.0 | False | None | None | False | None | False | 398395.65 | 0 |
| 3566224 | 129356 | None | code151 | Above 9.60m to 12.60m Level | Sqm | 724.86 | 724.86 | 2853.0 | False | None | None | False | None | False | 2068025.58 | 0 |
| 3566225 | 129356 | None | code152 | Above 12.60m to 15.60m Level | Sqm | 731.9 | 731.9 | 185.0 | False | None | None | False | None | False | 135401.5 | 0 |
| 3566226 | 129356 | None | code153 | Above 18.60m to 21.60m Level | Sqm | 745.98 | 745.98 | 1688.0 | False | None | None | False | None | False | 1259214.24 | 0 |
| 3566227 | 129356 | None | code154 | do -- For Cladding
0.00m to 3.60m Level | Sqm | 774.13 | 774.13 | 196.0 | False | None | None | False | None | False | 151729.48 | 0 |
| 3566228 | 129356 | None | code155 | Above 3.60m to 6.60m Level | Sqm | 781.87 | 781.87 | 646.0 | False | None | None | False | None | False | 505088.02 | 0 |
| 3566229 | 129356 | None | code156 | Above 6.60m to 9.60m Level | Sqm | 789.61 | 789.61 | 1036.0 | False | None | None | False | None | False | 818035.96 | 0 |
| 3566230 | 129356 | None | code157 | Above 9.60m to 12.60m Level | Sqm | 797.35 | 797.35 | 976.0 | False | None | None | False | None | False | 778213.6 | 0 |
| 3566231 | 129356 | None | code158 | Above 12.60m to 15.60m Level | Sqm | 805.09 | 805.09 | 586.0 | False | None | None | False | None | False | 471782.74 | 0 |
| 3566232 | 129356 | None | code159 | Above 15.60m to 18.60m Level | Sqm | 812.83 | 812.83 | 586.0 | False | None | None | False | None | False | 476318.38 | 0 |
| 3566233 | 129356 | None | code160 | Above 18.60m to 21.60m Level | Sqm | 820.57 | 820.57 | 391.0 | False | None | None | False | None | False | 320842.87 | 0 |
| 3566234 | 129356 | None | code161 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges Plain
Above 9.60m to 12.60m Level | Sqm | 959.25 | 959.25 | 47.0 | False | None | None | False | None | False | 45084.75 | 0 |
| 3566235 | 129356 | None | code162 | Above 18.60m to 21.60m Level | Sqm | 987.19 | 987.19 | 64.0 | False | None | None | False | None | False | 63180.16 | 0 |
| 3566236 | 129356 | None | code163 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Gutter
0.00m to 3.60m Level | Sqm | 2217.81 | 2217.81 | 106.0 | False | None | None | False | None | False | 235087.86 | 0 |
| 3566237 | 129356 | None | code164 | Above 3.60m to 6.60m Level | Sqm | 2239.99 | 2239.99 | 76.0 | False | None | None | False | None | False | 170239.24 | 0 |
| 3566238 | 129356 | None | code165 | Above 6.60m to 9.60m Level | Sqm | 2262.17 | 2262.17 | 339.0 | False | None | None | False | None | False | 766875.63 | 0 |
| 3566239 | 129356 | None | code166 | Above 9.60m to 12.60m Level | Sqm | 2284.34 | 2284.34 | 40.0 | False | None | None | False | None | False | 91373.6 | 0 |
| 3566240 | 129356 | None | code167 | Above 12.60m to 15.60m Level | Sqm | 2306.52 | 2306.52 | 40.0 | False | None | None | False | None | False | 92260.8 | 0 |
| 3566241 | 129356 | None | code168 | Above 15.60m to 18.60m Level | Sqm | 2328.7 | 2328.7 | 40.0 | False | None | None | False | None | False | 93148.0 | 0 |
| 3566242 | 129356 | None | code169 | Above 18.60m to 21.60m Level | Sqm | 2350.88 | 2350.88 | 167.0 | False | None | None | False | None | False | 392596.96 | 0 |
| 3566243 | 129356 | None | code170 | P/F profiled 2mm thick Polycarbonate sheets for roof light as per details.
Above 9.60m to 12.60m Level | Sqm | 2592.22 | 2592.22 | 504.0 | False | None | None | False | None | False | 1306478.88 | 0 |
| 3566244 | 129356 | None | code171 | Above 18.60m to 21.60m Level | Sqm | 2667.72 | 2667.72 | 238.0 | False | None | None | False | None | False | 634917.36 | 0 |
| 3566245 | 129356 | None | code172 | Providing and fixing Aluminium Turbo ventilator complete as per technical specifications : Non Power Driven with 1.3mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not less than 6kg for Industrial use for area upto 100m2 for Industrial use
Above 9.60m to 12.60m Level | Nos | 7146.55 | 7146.55 | 31.0 | False | None | None | False | None | False | 221543.05 | 0 |
| 3566246 | 129356 | None | code173 | Above 18.60m to 21.60m Level | Nos | 7354.7 | 7354.7 | 20.0 | False | None | None | False | None | False | 147094.0 | 0 |
| 3566247 | 129356 | None | code174 | Providing & fixing 50X50X5mm S.S. Angles fixied on corners of exposed column including drilling holes in RCC with necessary machine screws etc as required
0.00m to 3.60m Level | m | 2660.13 | 2660.13 | 227.0 | False | None | None | False | None | False | 603849.51 | 0 |
| 3566248 | 129356 | None | code175 | Above 3.60m to 6.60m Level | m | 2686.73 | 2686.73 | 42.0 | False | None | None | False | None | False | 112842.66 | 0 |
| 3566249 | 129356 | None | code176 | Above 6.60m to 9.60m Level | m | 2713.34 | 2713.34 | 84.0 | False | None | None | False | None | False | 227920.56 | 0 |
| 3566250 | 129356 | None | code177 | Above 12.60m to 15.60m Level | m | 2766.54 | 2766.54 | 126.0 | False | None | None | False | None | False | 348584.04 | 0 |
| 3566251 | 129356 | None | code178 | Above 18.60m to 21.60m Level | m | 2819.74 | 2819.74 | 108.0 | False | None | None | False | None | False | 304531.92 | 0 |
| 3566252 | 129356 | None | code179 | Above 24.60m to 27.60m Level | m | 2872.94 | 2872.94 | 117.0 | False | None | None | False | None | False | 336133.98 | 0 |
| 3566253 | 129356 | None | code180 | Above 27.60m to 30.60m Level | m | 2899.54 | 2899.54 | 34.0 | False | None | None | False | None | False | 98584.36 | 0 |
| 3566254 | 129356 | None | code181 | Above 30.60m to 33.60m Level | m | 2926.15 | 2926.15 | 68.0 | False | None | None | False | None | False | 198978.2 | 0 |
| 3566255 | 129356 | None | code182 | Providing and fixing Stainless Steel Work using SS angles, flats, plates, tubes etc work includes cutting, placing in position and welding wherever necessary including cost of all materials, labour charges, and hire charges of machineries for cutting, welding, grinding and erection equipments with all lead and lift, transportation etc., complete as per specification.
Above 0.00m to 3.60m Level | Kgs | 700.04 | 700.04 | 461.0 | False | None | None | False | None | False | 322718.44 | 0 |
| 3566256 | 129356 | None | code183 | Above 3.60m to 6.60m Level | Kgs | 707.04 | 707.04 | 260.0 | False | None | None | False | None | False | 183830.4 | 0 |
| 3566257 | 129356 | None | code184 | Above 12.60m to 15.60m Level | Kgs | 728.04 | 728.04 | 260.0 | False | None | None | False | None | False | 189290.4 | 0 |
| 3566258 | 129356 | None | code185 | Above 18.60m to 21.60m Level | Kgs | 742.04 | 742.04 | 216.0 | False | None | None | False | None | False | 160280.64 | 0 |
| 3566259 | 129356 | None | code186 | Above 21.60m to 24.60m Level | Kgs | 749.04 | 749.04 | 245.0 | False | None | None | False | None | False | 183514.8 | 0 |
| 3566260 | 129356 | None | code187 | Above 27.60m to 30.60m Level | Kgs | 763.04 | 763.04 | 202.0 | False | None | None | False | None | False | 154134.08 | 0 |
| 3566261 | 129356 | None | code188 | Above 30.60m to 33.60m Level | Kgs | 770.04 | 770.04 | 202.0 | False | None | None | False | None | False | 155548.08 | 0 |
| 3566262 | 129356 | None | code189 | Supply & Installation of SS pipe 316L grade as per JIS 1253:2013 conforming to AISI316 standards : 200mm dia (219 mm outer dia Dia OD 2.7 MM Thick)
Above 3.60m to 6.60m Level | m | 19885.84 | 19885.84 | 40.0 | False | None | None | False | None | False | 795433.6 | 0 |
| 3566263 | 129356 | None | code190 | Supply & Installation of SS pipe 316L grade : 150mm dia (154.5 mm OD 2.7 MM Thick) in ceiling with proper slope & support
Above 0.00m to 3.60m Level | m | 15120.76 | 15120.76 | 23.0 | False | None | None | False | None | False | 347777.48 | 0 |
| 3566264 | 129356 | None | code191 | Above 3.60m to 6.60m Level | m | 15271.96 | 15271.96 | 48.0 | False | None | None | False | None | False | 733054.08 | 0 |
| 3566265 | 129356 | None | code192 | Above 6.60m to 9.60m Level | m | 15423.17 | 15423.17 | 42.0 | False | None | None | False | None | False | 647773.14 | 0 |
| 3566266 | 129356 | None | code193 | Above 9.60m to 12.60m Level | m | 15574.38 | 15574.38 | 21.0 | False | None | None | False | None | False | 327061.98 | 0 |
| 3566267 | 129356 | None | code194 | Above 12.60m to 15.60m Level | m | 15725.59 | 15725.59 | 41.0 | False | None | None | False | None | False | 644749.19 | 0 |
| 3566268 | 129356 | None | code195 | Above 15.60m to 18.60m Level | m | 15876.79 | 15876.79 | 31.0 | False | None | None | False | None | False | 492180.49 | 0 |
| 3566269 | 129356 | None | code196 | Above 18.60m to 21.60m Level | m | 16028.0 | 16028.0 | 66.0 | False | None | None | False | None | False | 1057848.0 | 0 |
| 3566270 | 129356 | None | code197 | Above 21.60m to 24.60m Level | m | 16179.21 | 16179.21 | 34.0 | False | None | None | False | None | False | 550093.14 | 0 |
| 3566271 | 129356 | None | code198 | Above 24.60m to 27.60m Level | m | 16330.42 | 16330.42 | 14.0 | False | None | None | False | None | False | 228625.88 | 0 |
| 3566272 | 129356 | None | code199 | Above 27.60m to 30.60m Level | m | 16481.62 | 16481.62 | 24.0 | False | None | None | False | None | False | 395558.88 | 0 |
| 3566273 | 129356 | None | code200 | Above 30.60m to 33.60m Level | m | 16632.83 | 16632.83 | 14.0 | False | None | None | False | None | False | 232859.62 | 0 |
| 3566274 | 129356 | None | code201 | Supply & Installation of Industrial Floor Trap (AMUL TRAP) 316 L Grade 300x300x300mm outlet 114 Dia OD 100mm Length insrted into Main Drain Line
Above 0.00m to 3.60m Level | Nos | 16380.82 | 16380.82 | 12.0 | False | None | None | False | None | False | 196569.84 | 0 |
| 3566275 | 129356 | None | code202 | Above 3.60m to 6.60m Level | Nos | 16544.63 | 16544.63 | 12.0 | False | None | None | False | None | False | 198535.56 | 0 |
| 3566276 | 129356 | None | code203 | Above 9.60m to 12.60m Level | Nos | 16872.24 | 16872.24 | 2.0 | False | None | None | False | None | False | 33744.48 | 0 |
| 3566277 | 129356 | None | code204 | Above 12.60m to 15.60m Level | Nos | 17036.05 | 17036.05 | 2.0 | False | None | None | False | None | False | 34072.1 | 0 |
| 3566278 | 129356 | None | code205 | Above 18.60m to 21.60m Level | Nos | 17363.67 | 17363.67 | 12.0 | False | None | None | False | None | False | 208364.04 | 0 |
| 3566279 | 129356 | None | code206 | Above 21.60m to 24.60m Level | Nos | 17527.48 | 17527.48 | 8.0 | False | None | None | False | None | False | 140219.84 | 0 |
| 3566280 | 129356 | None | code207 | Above 24.60m to 27.60m Level | Nos | 17691.28 | 17691.28 | 2.0 | False | None | None | False | None | False | 35382.56 | 0 |
| 3566281 | 129356 | None | code208 | Above 27.60m to 30.60m Level | Nos | 17855.09 | 17855.09 | 5.0 | False | None | None | False | None | False | 89275.45 | 0 |
| 3566282 | 129356 | None | code209 | Above 30.60m to 33.60m Level | Nos | 18018.9 | 18018.9 | 2.0 | False | None | None | False | None | False | 36037.8 | 0 |
| 3566283 | 129356 | None | code210 | Core Cutting holes 200 to 300mm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded tone aggregate 20 mm nominal size) with water proof sealant including finishing complete so as to make it leak proof.
Above 3.60m to 6.60m Level | Nos | 1723.16 | 1723.16 | 12.0 | False | None | None | False | None | False | 20677.92 | 0 |
| 3566284 | 129356 | None | code211 | Above 9.60m to 12.60m Level | Nos | 1757.29 | 1757.29 | 2.0 | False | None | None | False | None | False | 3514.58 | 0 |
| 3566285 | 129356 | None | code212 | Above 12.60m to 15.60m Level | Nos | 1774.35 | 1774.35 | 2.0 | False | None | None | False | None | False | 3548.7 | 0 |
| 3566286 | 129356 | None | code213 | Above 18.60m to 21.60m Level | Nos | 1808.47 | 1808.47 | 12.0 | False | None | None | False | None | False | 21701.64 | 0 |
| 3566287 | 129356 | None | code214 | Above 21.60m to 24.60m Level | Nos | 1825.53 | 1825.53 | 8.0 | False | None | None | False | None | False | 14604.24 | 0 |
| 3566288 | 129356 | None | code215 | Above 24.60m to 27.60m Level | Nos | 1842.59 | 1842.59 | 2.0 | False | None | None | False | None | False | 3685.18 | 0 |
| 3566289 | 129356 | None | code216 | Above 27.60m to 30.60m Level | Nos | 1859.65 | 1859.65 | 5.0 | False | None | None | False | None | False | 9298.25 | 0 |
| 3566290 | 129356 | None | code217 | Above 30.60m to 33.60m Level | Nos | 1876.71 | 1876.71 | 2.0 | False | None | None | False | None | False | 3753.42 | 0 |
| 3566291 | 129356 | None | code218 | Providing and fixing 600 x600 size C.I. frames with cover of approved Ist quality and make conforming to I.S.I. Specification and fixing in C.C. (1:2:4) 7.5 cms thick including curing (Rate includes cost of all materials and conveyance to work spot). | Nos | 3097.5 | 3097.5 | 7.0 | False | None | None | False | None | False | 21682.5 | 0 |
| 3566292 | 129356 | None | code219 | 19.16 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. | Nos | 685.17 | 685.17 | 35.0 | False | None | None | False | None | False | 23980.95 | 0 |
| 3566293 | 129356 | None | code220 | P/f. 15 to 50 mm dia Puddle flanges in rcc using GI Pipes with 6mm thk. Plate as flage as per details. | Nos | 414.18 | 414.18 | 7.0 | False | None | None | False | None | False | 2899.26 | 0 |
| 3566294 | 129356 | None | code221 | do-- 65 to 100 mm dia Puddle flanges. | Nos | 709.18 | 709.18 | 14.0 | False | None | None | False | None | False | 9928.52 | 0 |
| 3566295 | 129356 | None | code222 | Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey.
450mm dia | m | 2915.37 | 2915.37 | 750.0 | False | None | None | False | None | False | 2186527.5 | 0 |
| 3566296 | 129356 | None | code223 | do-- 300mm dia | m | 1650.35 | 1650.35 | 250.0 | False | None | None | False | None | False | 412587.5 | 0 |
| 3566297 | 129356 | None | code224 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
600 x 300 x 150 mm size | m | 573.66 | 573.66 | 3000.0 | False | None | None | False | None | False | 1720980.0 | 0 |
| 3566298 | 129356 | None | code225 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with PVC Pipe 110mm outer dia at 2 kg per m2, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications | m | 170.98 | 170.98 | 4850.0 | False | None | None | False | None | False | 829253.0 | 0 |
| 3566299 | 129356 | None | code226 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. | Cum | 3761.6 | 3761.6 | 920.0 | False | None | None | False | None | False | 3460672.0 | 0 |
| 3566300 | 129356 | None | code227 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications A. Stone/Boulder | Cum | 2368.97 | 2368.97 | 2103.0 | False | None | None | False | None | False | 4981943.91 | 0 |
| 3566301 | 129356 | None | code228 | B SANITARY - PLUMBING WORKS :
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
0.00m to 3.60m Level | Nos | 6051.28 | 6051.28 | 1.0 | False | None | None | False | None | False | 6051.28 | 0 |
| 3566302 | 129356 | None | code229 | Above 3.60m to 6.60m Level | Nos | 6111.79 | 6111.79 | 1.0 | False | None | None | False | None | False | 6111.79 | 0 |
| 3566303 | 129356 | None | code230 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
0.00m to 3.60m Level | Nos | 7405.5 | 7405.5 | 8.0 | False | None | None | False | None | False | 59244.0 | 0 |
| 3566304 | 129356 | None | code231 | Above 3.60m to 6.60m Level | Nos | 7479.56 | 7479.56 | 8.0 | False | None | None | False | None | False | 59836.48 | 0 |
| 3566305 | 129356 | None | code232 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
0.00m to 3.60m Level | Nos | 337.01 | 337.01 | 9.0 | False | None | None | False | None | False | 3033.09 | 0 |
| 3566306 | 129356 | None | code233 | Above 3.60m to 6.60m Level | Nos | 340.38 | 340.38 | 9.0 | False | None | None | False | None | False | 3063.42 | 0 |
| 3566307 | 129356 | None | code234 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
0.00m to 3.60m Level | Nos | 1429.81 | 1429.81 | 4.0 | False | None | None | False | None | False | 5719.24 | 0 |
| 3566308 | 129356 | None | code235 | Above 3.60m to 6.60m Level | Nos | 1444.1 | 1444.1 | 4.0 | False | None | None | False | None | False | 5776.4 | 0 |
| 3566309 | 129356 | None | code236 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 g.
0.00m to 3.60m Level | Nos | 113.99 | 113.99 | 4.0 | False | None | None | False | None | False | 455.96 | 0 |
| 3566310 | 129356 | None | code237 | Above 3.60m to 6.60m Level | Nos | 115.13 | 115.13 | 4.0 | False | None | None | False | None | False | 460.52 | 0 |
| 3566311 | 129356 | None | code238 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.
0.00m to 3.60m Level | Nos | 3455.57 | 3455.57 | 4.0 | False | None | None | False | None | False | 13822.28 | 0 |
| 3566312 | 129356 | None | code239 | Above 3.60m to 6.60m Level | Nos | 3490.13 | 3490.13 | 4.0 | False | None | None | False | None | False | 13960.52 | 0 |
| 3566313 | 129356 | None | code240 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
0.00m to 3.60m Level | Nos | 3173.08 | 3173.08 | 10.0 | False | None | None | False | None | False | 31730.8 | 0 |
| 3566314 | 129356 | None | code241 | Above 3.60m to 6.60m Level | Nos | 3204.81 | 3204.81 | 10.0 | False | None | None | False | None | False | 32048.1 | 0 |
| 3566315 | 129356 | None | code242 | Providing and fixing CI / PVC Nahani trap of approved make conforming to ISI specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). 100x75mm including grating
0.00m to 3.60m Level | Nos | 272.58 | 272.58 | 44.0 | False | None | None | False | None | False | 11993.52 | 0 |
| 3566316 | 129356 | None | code243 | Above 3.60m to 6.60m Level | Nos | 275.31 | 275.31 | 25.0 | False | None | None | False | None | False | 6882.75 | 0 |
| 3566317 | 129356 | None | code244 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
0.00m to 3.60m Level | Nos | 786.77 | 786.77 | 14.0 | False | None | None | False | None | False | 11014.78 | 0 |
| 3566318 | 129356 | None | code245 | Above 3.60m to 6.60m Level | Nos | 794.63 | 794.63 | 6.0 | False | None | None | False | None | False | 4767.78 | 0 |
| 3566319 | 129356 | None | code246 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
0.00m to 3.60m Level | Nos | 898.28 | 898.28 | 35.0 | False | None | None | False | None | False | 31439.8 | 0 |
| 3566320 | 129356 | None | code247 | Above 3.60m to 6.60m Level | Nos | 907.26 | 907.26 | 15.0 | False | None | None | False | None | False | 13608.9 | 0 |
| 3566321 | 129356 | None | code248 | P/F. S.S. Pipes (316 grade aproved make) with specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, welding/ threading etc. complete for soft water lines. a)22mm dia. | m | 1270.28 | 1270.28 | 15.0 | False | None | None | False | None | False | 19054.2 | 0 |
| 3566322 | 129356 | None | code249 | b) 28 mm dia | m | 1576.19 | 1576.19 | 25.0 | False | None | None | False | None | False | 39404.75 | 0 |
| 3566323 | 129356 | None | code250 | c) 42 mm dia | m | 2631.64 | 2631.64 | 25.0 | False | None | None | False | None | False | 65791.0 | 0 |
| 3566324 | 129356 | None | code251 | P/F. I.S.I. Approved make, S.S. Ball valves, fixing in the water supply lines with threaded joints.
a) 22mm dia | Nos | 3568.32 | 3568.32 | 2.0 | False | None | None | False | None | False | 7136.64 | 0 |
| 3566325 | 129356 | None | code252 | b) 28 mm dia | Nos | 4163.04 | 4163.04 | 4.0 | False | None | None | False | None | False | 16652.16 | 0 |
| 3566326 | 129356 | None | code253 | c) 42 mm dia | Nos | 7051.68 | 7051.68 | 1.0 | False | None | None | False | None | False | 7051.68 | 0 |
| 3566327 | 129356 | None | code254 | P/F. UPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete. a) 25 mm dia
0.00m to 3.60m Level | m | 319.17 | 319.17 | 100.0 | False | None | None | False | None | False | 31917.0 | 0 |
| 3566328 | 129356 | None | code255 | Above 3.60m to 6.60m Level | m | 322.36 | 322.36 | 50.0 | False | None | None | False | None | False | 16118.0 | 0 |
| 3566329 | 129356 | None | code256 | b) 32 mm dia
0.00m to 3.60m Level | m | 387.56 | 387.56 | 130.0 | False | None | None | False | None | False | 50382.8 | 0 |
| 3566330 | 129356 | None | code257 | Above 3.60m to 6.60m Level | m | 391.43 | 391.43 | 30.0 | False | None | None | False | None | False | 11742.9 | 0 |
| 3566331 | 129356 | None | code258 | c) 50 mm dia
0.00m to 3.60m Level | m | 478.25 | 478.25 | 110.0 | False | None | None | False | None | False | 52607.5 | 0 |
| 3566332 | 129356 | None | code259 | Above 3.60m to 6.60m Level | m | 483.04 | 483.04 | 10.0 | False | None | None | False | None | False | 4830.4 | 0 |
| 3566333 | 129356 | None | code260 | d) 65 mm dia
0.00m to 3.60m Level | m | 672.78 | 672.78 | 25.0 | False | None | None | False | None | False | 16819.5 | 0 |
| 3566334 | 129356 | None | code261 | Above 3.60m to 6.60m Level | m | 679.5 | 679.5 | 25.0 | False | None | None | False | None | False | 16987.5 | 0 |
| 3566335 | 129356 | None | code262 | P/F Chorinated Poly chloride (CPVC) pipes, having thermal stabilty for hot and clod water supply inclding all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00mtr spacing. This includes jointing of pipes and fittings with one setp CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work, including cutting chases and making good the walls etc. a) 20mm dia.
0.00m to 3.60m Level | m | 469.58 | 469.58 | 80.0 | False | None | None | False | None | False | 37566.4 | 0 |
| 3566336 | 129356 | None | code263 | Above 3.60m to 6.60m Level | m | 474.28 | 474.28 | 20.0 | False | None | None | False | None | False | 9485.6 | 0 |
| 3566337 | 129356 | None | code264 | b) 25mm dia.
0.00m to 3.60m Level | m | 591.0 | 591.0 | 120.0 | False | None | None | False | None | False | 70920.0 | 0 |
| 3566338 | 129356 | None | code265 | Above 3.60m to 6.60m Level | m | 596.91 | 596.91 | 40.0 | False | None | None | False | None | False | 23876.4 | 0 |
| 3566339 | 129356 | None | code266 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
0.00m to 3.60m Level | Nos | 389.05 | 389.05 | 10.0 | False | None | None | False | None | False | 3890.5 | 0 |
| 3566340 | 129356 | None | code267 | Above 3.60m to 6.60m Level | Nos | 392.94 | 392.94 | 6.0 | False | None | None | False | None | False | 2357.64 | 0 |
| 3566341 | 129356 | None | code268 | 25 mm dia:
0.00m to 3.60m Level | Nos | 680.21 | 680.21 | 8.0 | False | None | None | False | None | False | 5441.68 | 0 |
| 3566342 | 129356 | None | code269 | Above 3.60m to 6.60m Level | Nos | 687.01 | 687.01 | 4.0 | False | None | None | False | None | False | 2748.04 | 0 |
| 3566343 | 129356 | None | code270 | 32 mm dia:
0.00m to 3.60m Level | Nos | 740.92 | 740.92 | 3.0 | False | None | None | False | None | False | 2222.76 | 0 |
| 3566344 | 129356 | None | code271 | Above 3.60m to 6.60m Level | Nos | 748.33 | 748.33 | 3.0 | False | None | None | False | None | False | 2244.99 | 0 |
| 3566345 | 129356 | None | code272 | d) 50 mm dia.
0.00m to 3.60m Level | Nos | 1059.35 | 1059.35 | 4.0 | False | None | None | False | None | False | 4237.4 | 0 |
| 3566346 | 129356 | None | code273 | Above 3.60m to 6.60m Level | Nos | 1069.94 | 1069.94 | 2.0 | False | None | None | False | None | False | 2139.88 | 0 |
| 3566347 | 129356 | None | code274 | e) 65 mm dia.
0.00m to 3.60m Level | Nos | 1748.23 | 1748.23 | 1.0 | False | None | None | False | None | False | 1748.23 | 0 |
| 3566348 | 129356 | None | code275 | Above 3.60m to 6.60m Level | Nos | 1765.71 | 1765.71 | 1.0 | False | None | None | False | None | False | 1765.71 | 0 |
| 3566349 | 129356 | None | code276 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
0.00m to 3.60m Level | Nos | 1511.58 | 1511.58 | 15.0 | False | None | None | False | None | False | 22673.7 | 0 |
| 3566350 | 129356 | None | code277 | Above 3.60m to 6.60m Level | Nos | 1526.7 | 1526.7 | 10.0 | False | None | None | False | None | False | 15267.0 | 0 |
| 3566351 | 129356 | None | code278 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
0.00m to 3.60m Level | Nos | 614.54 | 614.54 | 15.0 | False | None | None | False | None | False | 9218.1 | 0 |
| 3566352 | 129356 | None | code279 | Above 3.60m to 6.60m Level | Nos | 620.69 | 620.69 | 10.0 | False | None | None | False | None | False | 6206.9 | 0 |
| 3566353 | 129356 | None | code280 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
0.00m to 3.60m Level | Nos | 345.68 | 345.68 | 3.0 | False | None | None | False | None | False | 1037.04 | 0 |
| 3566354 | 129356 | None | code281 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
0.00m to 3.60m Level | m | 6891.32 | 6891.32 | 3.0 | False | None | None | False | None | False | 20673.96 | 0 |
| 3566355 | 129356 | None | code282 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board - 610x510 mm bowl depth 200 mm
0.00m to 3.60m Level | Nos | 4491.38 | 4491.38 | 2.0 | False | None | None | False | None | False | 8982.76 | 0 |
| 3566356 | 129356 | None | code283 | Above 3.60m to 6.60m Level | Nos | 4536.29 | 4536.29 | 1.0 | False | None | None | False | None | False | 4536.29 | 0 |
| 3566357 | 129356 | None | code284 | Providing and fixing Stainless Steel 304 Kitchen Drain 300 X100 x1030 mm of size fixing in flooring requred slope with perforated, removable s s cover as per instructions. | Nos | 14868.0 | 14868.0 | 4.0 | False | None | None | False | None | False | 59472.0 | 0 |
| 3566358 | 129356 | None | code285 | Providing and fixing Stainless Steel 304 Kitchen Drain 300 X100 x2030 mm of size fixing in flooring requred slope with perforated, removable cover as per instructions. | Nos | 21240.0 | 21240.0 | 2.0 | False | None | None | False | None | False | 42480.0 | 0 |
| 3566359 | 129356 | None | code286 | Providing & fixing S.S. Handwash trough 450mm wide made out of 304 grade, 1.00mm thick s.s. sheets with waste connections etc complete as per details. | m | 10874.88 | 10874.88 | 15.0 | False | None | None | False | None | False | 163123.2 | 0 |
| 3566360 | 129356 | None | code287 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (including cost of all specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: a) PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 327.1 | 327.1 | 150.0 | False | None | None | False | None | False | 49065.0 | 0 |
| 3566361 | 129356 | None | code288 | Above 3.60m to 6.60m Level | m | 330.37 | 330.37 | 75.0 | False | None | None | False | None | False | 24777.75 | 0 |
| 3566362 | 129356 | None | code289 | b) PVC pipes 110mm dia., 6 kg/sqcm & class 3
0.00m to 3.60m Level | m | 611.07 | 611.07 | 250.0 | False | None | None | False | None | False | 152767.5 | 0 |
| 3566363 | 129356 | None | code290 | Above 3.60m to 6.60m Level | m | 617.19 | 617.19 | 75.0 | False | None | None | False | None | False | 46289.25 | 0 |
| 3566364 | 129356 | None | code291 | c) PVC pipes 160mm dia., 6 kg/sqcm & class 3
0.00m to 3.60m Level | m | 918.84 | 918.84 | 50.0 | False | None | None | False | None | False | 45942.0 | 0 |
| 3566365 | 129356 | None | code292 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Nos | 428.69 | 428.69 | 21.0 | False | None | None | False | None | False | 9002.49 | 0 |
| 3566366 | 129356 | None | code293 | Making bores / Drilling Holes (75mm to 150dia) & making good for Sanitary Pipes including cost of materials, labour, HOM complete as per specifications.
In Brick / Block Masonry | Nos | 212.4 | 212.4 | 35.0 | False | None | None | False | None | False | 7434.0 | 0 |
| 3566367 | 129356 | None | code294 | In Stone Masonry (Upto 600mm Thk SSM) | Nos | 354.0 | 354.0 | 30.0 | False | None | None | False | None | False | 10620.0 | 0 |
| 3566368 | 129356 | None | code295 | In RCC Slabs / Chejja (Upto 150mm Thk RCC) | Nos | 354.0 | 354.0 | 10.0 | False | None | None | False | None | False | 3540.0 | 0 |
| 3566369 | 129356 | None | code296 | Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I. cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 Kg (Weight of cover 23Kg and weight of frame 15Kg) R.C.C. top slab with cement concrete 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.
a) 455X610X450 | Nos | 6990.44 | 6990.44 | 20.0 | False | None | None | False | None | False | 139808.8 | 0 |
| 3566370 | 129356 | None | code297 | b) 455X610X450 - 750 | Nos | 9384.93 | 9384.93 | 11.0 | False | None | None | False | None | False | 103234.23 | 0 |
| 3566371 | 129356 | None | code298 | c) 500X700X600 -750 | Nos | 10388.52 | 10388.52 | 6.0 | False | None | None | False | None | False | 62331.12 | 0 |
| 3566372 | 129356 | None | code299 | Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.2 M depth & SFRC cover & frame | Nos | 38867.43 | 38867.43 | 6.0 | False | None | None | False | None | False | 233204.58 | 0 |
| 3566373 | 129356 | None | code300 | Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.5 M depth & SFRC cover & frame | Nos | 47554.06 | 47554.06 | 3.0 | False | None | None | False | None | False | 142662.18 | 0 |
| 3566374 | 129356 | None | code301 | Providing and fixing rectangular high density polythylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making ncessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixures for tank shall be paid seperately. | l | 11.26 | 11.26 | 7000.0 | False | None | None | False | None | False | 78820.0 | 0 |
| 3566375 | 129356 | None | code302 | C ELECTRICAL WORKS : 1 LT PANEL AND MCB DISTRIBUTION BOARDS : Supply, installation, testing and commissioning of M.V. panels and switch gears suitable for 415V, 3 phase, 4 wire, 50Hz power distribution system. The panel shall be free standing floor mounting type 14G/16G sheet steel enclosed, flush front with aluminium bus bars and separate earth bus to be provided through out the length of the panel. The incoming and out going feeders breakers, changer over switches, fuses indicating lamps shall be accomadated in a modular multitier arangement. Minimum clearance of 400mm shall be provided from the floor level to the bottom most termination point adequate size cable alley and bus bar chamber shall be provided, all round the panel and it shall be connected through solid bus bars. Flexible cable links are not acceptable . Bus bars shall be provided with sleeves or heat resistant insulated paint. The paint shall be suitable for both top/bottom cable entry. The minimum fault rupturing capacity of all incoming and out going breakers/ switches shall be as per SLD only. The panel shall be painted in conformity with the relevant IS code. The panel shall be fabricated only after obtaining approval of the GA drawings. The rate shall also include cost of civil works including fixing accessories, all complete as required SDB- ENTRANCE ARCH / CANTEEN Incomer : 1no. 100A, TPN MCCB 1set of RYB indicating lamps 1no. VAF meter with suitable CT 1no. ELR with CBCT 1 set of 100A, TPN+E, Al. Busbar Outgoings : 2nos. 63A, TPN MCB 4nos. 25A, TPN MCB 1no. 32A, TPN MCB 1no. 20A, TPN MCB | Set | 68600.99 | 68600.99 | 2.0 | False | None | None | False | None | False | 137201.98 | 0 |
| 3566376 | 129356 | None | code303 | DISTRIBUTION BOARDS: Supplying and fixing regular MCB distribution boards on wall/wood board/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ double door with powder coated painting made out of 14 SWG MS enclosure etc, complete as required.
LDB -TYPE-1
4 Way TPN MCB DB
Incomer :
1 No. 25A 4P ELMCB 100mA
Outgoings :
12 nos. of 6/10A SP MCBs | Set | 17973.58 | 17973.58 | 1.0 | False | None | None | False | None | False | 17973.58 | 0 |
| 3566377 | 129356 | None | code304 | LDB -TYPE-2
6 Way TPN MCB DB
Incomer :
1 No. 25A 4P RCCB 100mA + 25A TPN MCB
Outgoings :
18 nos. of 6/10A SP MCBs | Set | 24493.53 | 24493.53 | 1.0 | False | None | None | False | None | False | 24493.53 | 0 |
| 3566378 | 129356 | None | code305 | LDB -TYPE-3
DB : 6 Way TPN MCB DB
Incomer :
1 No. 25A 4P ELMCB 100mA
Outgoings :
18 nos. of 6/10A SP MCBs | Set | 22302.35 | 22302.35 | 1.0 | False | None | None | False | None | False | 22302.35 | 0 |
| 3566379 | 129356 | None | code306 | MCB DISTRIBUTION BOARDS: Supplying and fixing regular MCB distribution boards on wall/wood board/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ double door with powder coated painting made out of 14 SWG MS enclosure etc, complete as required.
UPSDB -TYPE-1
4 Way TPN MCB DB
Incomer :
1 No. 25A TPN MCB
Outgoings :
12 nos. of 6/10A SP MCBs | Set | 13699.68 | 13699.68 | 1.0 | False | None | None | False | None | False | 13699.68 | 0 |
| 3566380 | 129356 | None | code307 | RPDB -TYPE-1
12 Way TPN MCB DB
Incomer :
1 No. 63A 4P ELMCB 300mA
Outgoings :
6 nos. of 16/20A TP MCBs
18 nos. of 16/20A SP MCBs | Set | 54050.9 | 54050.9 | 1.0 | False | None | None | False | None | False | 54050.9 | 0 |
| 3566381 | 129356 | None | code308 | LIFT DB
2 row 14 modules flexy DB
Incomer:
32A 4P ELMCB 300mA
Outgoing
1 No . of 32A TPN MCB
3Nos. of 6/16A SP MCBs | Set | 18624.42 | 18624.42 | 1.0 | False | None | None | False | None | False | 18624.42 | 0 |
| 3566382 | 129356 | None | code309 | Supply, installation, testing and commissioning following sizes MCB in IP 65 Weather proof enclosure. The rate shall include cost of MCB. The MCB shall be wall mounted using necessary brackets and fixing accessories.16A, SP MCB | Nos | 514.19 | 514.19 | 2.0 | False | None | None | False | None | False | 1028.38 | 0 |
| 3566383 | 129356 | None | code310 | 16A, TPN MCB | Nos | 2127.36 | 2127.36 | 5.0 | False | None | None | False | None | False | 10636.8 | 0 |
| 3566384 | 129356 | None | code311 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant, PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975
3.5C 70 sqmm | m | 433.65 | 433.65 | 500.0 | False | None | None | False | None | False | 216825.0 | 0 |
| 3566385 | 129356 | None | code312 | 4C 10 sqmm | m | 161.07 | 161.07 | 50.0 | False | None | None | False | None | False | 8053.5 | 0 |
| 3566386 | 129356 | None | code313 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe as required.
3.5C 70 sqmm | m | 19.2 | 19.2 | 750.0 | False | None | None | False | None | False | 14400.0 | 0 |
| 3566387 | 129356 | None | code314 | Labour charges for laying of 1.1 KV class UG cable in On wall /Structure as required.
4C 10 sqmm | m | 37.17 | 37.17 | 50.0 | False | None | None | False | None | False | 1858.5 | 0 |
| 3566388 | 129356 | None | code315 | LT CABLE END TERMINATIONS: Supplying and fixing of heavy duty cable glands for UG cable of 1.11kV class (metal only)
20 mm dia | Nos | 84.25 | 84.25 | 2.0 | False | None | None | False | None | False | 168.5 | 0 |
| 3566389 | 129356 | None | code316 | 45 mm dia | Nos | 240.37 | 240.37 | 2.0 | False | None | None | False | None | False | 480.74 | 0 |
| 3566390 | 129356 | None | code317 | Supplying tinned copper lugs and soldering using necessary soldering materials or crimping and wiring to terminal point for wire/cable of the following sizes.
10sqmm | Nos | 9.91 | 9.91 | 8.0 | False | None | None | False | None | False | 79.28 | 0 |
| 3566391 | 129356 | None | code318 | 35 sqmm | Nos | 39.65 | 39.65 | 2.0 | False | None | None | False | None | False | 79.3 | 0 |
| 3566392 | 129356 | None | code319 | 70 sqmm | Nos | 117.71 | 117.71 | 6.0 | False | None | None | False | None | False | 706.26 | 0 |
| 3566393 | 129356 | None | code320 | Supply & Laying of 1100V grade, XLPE/ PVC insulated, PVC sheathed, Aluminium / copper conductor, steel armoured cables. The cable shall be laid in exsiting trench, cable tray / clamped on to the walls using necessary fixing accessories, The cable shall be provided with cable identification tags made out of Aluminium strip, engraved with cable size and the routing. (Note : cost of cable tray, supports, excavation, sand cushioning, brick protection and back filling measured separately).
4C 6 sqmm Al. XLPE Cable | m | 406.39 | 406.39 | 1000.0 | False | None | None | False | None | False | 406390.0 | 0 |
| 3566394 | 129356 | None | code321 | Supply and providing end termination for below listed PVC insulated, PVC sheathed, aluminium conductor,steel armoured, 1100V grade , cable using brass cable glands and copper lugs etc, all complete as required.
4C 6 sqmm Al. XLPE Cable | Nos | 37.17 | 37.17 | 4.0 | False | None | None | False | None | False | 148.68 | 0 |
| 3566395 | 129356 | None | code322 | INTERNAL ELECTRICAL WORKS : Concealed conduit system : Supplying and fixing of PVC conduit of 20 mm dia, 2mm thick in the concealed slab / groove cutting including required bends and accessories, including supply and wiring of 2 x 1.5Sq mm + 1 x 1.0Sq mm FRLS PVC insulated copper wires for point wiring etc. complete as required. Short point upto 3 mtrs. | Nos | 582.33 | 582.33 | 16.0 | False | None | None | False | None | False | 9317.28 | 0 |
| 3566396 | 129356 | None | code323 | Medium point above 3 mtrs upto 6 mtrs. | Nos | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 |
| 3566397 | 129356 | None | code324 | Long point above 6 mtrs upto 10 mtrs. | Nos | 1517.78 | 1517.78 | 40.0 | False | None | None | False | None | False | 60711.2 | 0 |
| 3566398 | 129356 | None | code325 | Two in a row above 3 mts upto 6 mtrs from tapping point to outlet via switch box | Nos | 1336.88 | 1336.88 | 67.0 | False | None | None | False | None | False | 89570.96 | 0 |
| 3566399 | 129356 | None | code326 | Three in a row above 6 mts upto10 mtrs from tapping point to outlet via switch box | Nos | 2055.5 | 2055.5 | 32.0 | False | None | None | False | None | False | 65776.0 | 0 |
| 3566400 | 129356 | None | code327 | Ceiling fan point controlled by 6A modular type switch and fan regulator. Medium point above 3 mtrs upto 6 mtrs. | Nos | 967.66 | 967.66 | 26.0 | False | None | None | False | None | False | 25159.16 | 0 |
| 3566401 | 129356 | None | code328 | Long point above 6 mtrs upto 10 mtrs. | Nos | 1517.78 | 1517.78 | 42.0 | False | None | None | False | None | False | 63746.76 | 0 |
| 3566402 | 129356 | None | code329 | Exhaust fan point (Single phase) controlled by 6A modular type switch and 6A socket outlet near the exhaust fan - Medium point above 3 mtrs upto 6 mtrs. | Nos | 967.66 | 967.66 | 9.0 | False | None | None | False | None | False | 8708.94 | 0 |
| 3566403 | 129356 | None | code330 | Long point above 6 mtrs upto 10 mtrs. | Nos | 1517.78 | 1517.78 | 5.0 | False | None | None | False | None | False | 7588.9 | 0 |
| 3566404 | 129356 | None | code331 | CIRCUIT MAIN / POWER MAIN / SUBMAINS : Supplying and wiring for lighting circuit mains/ power mains/submains, using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core cable in open or concealed slab / groove cutting system of wiring including required bends and accessories. 2x1.5 Sqmm +1x1.0 Sqmm PVC Insulated wires drawn in 20mm dia PVC conduit for additional length of point wiring. | m | 170.98 | 170.98 | 1100.0 | False | None | None | False | None | False | 188078.0 | 0 |
| 3566405 | 129356 | None | code332 | 2 x 2.5 Sqmm + 1 x 1.5 Sq mm PVC Insulated wires drawn in 20 mm dia PVC conduit for Lighting Circuit Mains | m | 219.3 | 219.3 | 1250.0 | False | None | None | False | None | False | 274125.0 | 0 |
| 3566406 | 129356 | None | code333 | 2 x 4 Sqmm + 1 x 2.5 Sq mm PVC Insulated wires drawn in 25 mm dia PVC conduit | m | 305.41 | 305.41 | 600.0 | False | None | None | False | None | False | 183246.0 | 0 |
| 3566407 | 129356 | None | code334 | 2 x 6 Sqmm + 1 x 4 Sq mm PVC Insulated wires drawn in 25 mm dia PVC conduit. | m | 431.17 | 431.17 | 30.0 | False | None | None | False | None | False | 12935.1 | 0 |
| 3566408 | 129356 | None | code335 | 4 x 4 Sqmm + 2 x 2.5 Sq mm PVC Insulated wires drawn in 32 mm dia PVC conduit | m | 541.44 | 541.44 | 300.0 | False | None | None | False | None | False | 162432.0 | 0 |
| 3566409 | 129356 | None | code336 | 4 x 6 Sqmm + 2 x 4 Sq mm PVC Insulated wires drawn in 32 mm dia PVC conduit. | m | 737.21 | 737.21 | 20.0 | False | None | None | False | None | False | 14744.2 | 0 |
| 3566410 | 129356 | None | code337 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/raceway as required.
4 x 16 Sqmm + 2 x 10 Sq mm PVC Insulated wires drawn in 40 mm dia PVC conduit | m | 2167.01 | 2167.01 | 30.0 | False | None | None | False | None | False | 65010.3 | 0 |
| 3566411 | 129356 | None | code338 | 2 x 2.5 Sqmm + 1 x 1.5 Sq mm PVC Insulated wires drawn in 20 mm MS conduit | m | 254.34 | 254.34 | 20.0 | False | None | None | False | None | False | 5086.8 | 0 |
| 3566412 | 129356 | None | code339 | 2 x 4 Sqmm + 1 x 2.5 Sq mm PVC Insulated wires drawn in 25 mm dia MS conduit | m | 352.22 | 352.22 | 20.0 | False | None | None | False | None | False | 7044.4 | 0 |
| 3566413 | 129356 | None | code340 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. ( Group-A) 1 to 3Way | Nos | 197.0 | 197.0 | 85.0 | False | None | None | False | None | False | 16745.0 | 0 |
| 3566414 | 129356 | None | code341 | 4Way | Nos | 219.3 | 219.3 | 28.0 | False | None | None | False | None | False | 6140.4 | 0 |
| 3566415 | 129356 | None | code342 | 6Way | Nos | 272.58 | 272.58 | 12.0 | False | None | None | False | None | False | 3270.96 | 0 |
| 3566416 | 129356 | None | code343 | 8Way | Nos | 323.38 | 323.38 | 31.0 | False | None | None | False | None | False | 10024.78 | 0 |
| 3566417 | 129356 | None | code344 | 10-12Way | Nos | 395.24 | 395.24 | 12.0 | False | None | None | False | None | False | 4742.88 | 0 |
| 3566418 | 129356 | None | code345 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group A materials 1 to 3 module | Nos | 199.48 | 199.48 | 85.0 | False | None | None | False | None | False | 16955.8 | 0 |
| 3566419 | 129356 | None | code346 | 4 module | Nos | 216.83 | 216.83 | 28.0 | False | None | None | False | None | False | 6071.24 | 0 |
| 3566420 | 129356 | None | code347 | 6 module | Nos | 289.93 | 289.93 | 12.0 | False | None | None | False | None | False | 3479.16 | 0 |
| 3566421 | 129356 | None | code348 | 8 module | Nos | 351.88 | 351.88 | 31.0 | False | None | None | False | None | False | 10908.28 | 0 |
| 3566422 | 129356 | None | code349 | 10-12 module | Nos | 426.22 | 426.22 | 12.0 | False | None | None | False | None | False | 5114.64 | 0 |
| 3566423 | 129356 | None | code350 | Supplying and fixing of modular switch/ Socket on existing modular switch plate 6Amps one way. Group B | Nos | 126.38 | 126.38 | 240.0 | False | None | None | False | None | False | 30331.2 | 0 |
| 3566424 | 129356 | None | code351 | 6Amps 3way socket. | Nos | 211.87 | 211.87 | 51.0 | False | None | None | False | None | False | 10805.37 | 0 |
| 3566425 | 129356 | None | code352 | 16Amps one way switch | Nos | 223.02 | 223.02 | 19.0 | False | None | None | False | None | False | 4237.38 | 0 |
| 3566426 | 129356 | None | code353 | 6/16Amps universal socket | Nos | 292.4 | 292.4 | 19.0 | False | None | None | False | None | False | 5555.6 | 0 |
| 3566427 | 129356 | None | code354 | Stepped Fan Regulator. | Nos | 442.32 | 442.32 | 68.0 | False | None | None | False | None | False | 30077.76 | 0 |
| 3566428 | 129356 | None | code355 | Supplying and fixing of metal clad industrial plugs and sockets.
10A, 2pole+earth 250V PLUG, | Nos | 480.43 | 480.43 | 5.0 | False | None | None | False | None | False | 2402.15 | 0 |
| 3566429 | 129356 | None | code356 | 20A, 3pole+earth 440V PLUG | Nos | 560.19 | 560.19 | 5.0 | False | None | None | False | None | False | 2800.95 | 0 |
| 3566430 | 129356 | None | code357 | 10A, 2pole+earth 250V SOCKET | Nos | 657.87 | 657.87 | 5.0 | False | None | None | False | None | False | 3289.35 | 0 |
| 3566431 | 129356 | None | code358 | 20A, 3pole+earth 440V SOCKET | Nos | 785.27 | 785.27 | 5.0 | False | None | None | False | None | False | 3926.35 | 0 |
| 3566432 | 129356 | None | code359 | SUPPLY & INSTALLATION OF LIGHT & FAN FIXTURES Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 5-6W | Nos | 707.47 | 707.47 | 16.0 | False | None | None | False | None | False | 11319.52 | 0 |
| 3566433 | 129356 | None | code360 | LED square or round down light 10-12W | Nos | 1096.52 | 1096.52 | 50.0 | False | None | None | False | None | False | 54826.0 | 0 |
| 3566434 | 129356 | None | code361 | LED square or round down light 15-18W | Nos | 1640.44 | 1640.44 | 65.0 | False | None | None | False | None | False | 106628.6 | 0 |
| 3566435 | 129356 | None | code362 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Nos | 682.69 | 682.69 | 5.0 | False | None | None | False | None | False | 3413.45 | 0 |
| 3566436 | 129356 | None | code363 | LED light fitting 1 x 4' - 20/22 W | Nos | 854.91 | 854.91 | 66.0 | False | None | None | False | None | False | 56424.06 | 0 |
| 3566437 | 129356 | None | code364 | LED light fitting 1 x 4' - 36/40 W | Nos | 1572.29 | 1572.29 | 72.0 | False | None | None | False | None | False | 113204.88 | 0 |
| 3566438 | 129356 | None | code365 | Supplying of 40 W LED IP-65 Tube Light fixture of type CIS-300-40-57-SL-DP-NGR of CG make/equivalent. | Nos | 2875.72 | 2875.72 | 2.0 | False | None | None | False | None | False | 5751.44 | 0 |
| 3566439 | 129356 | None | code366 | Supplying of 80W, LED, High efficeincy round high bay in PDC housing industiral light fixture of type LHB11-80-CDL/60-HPM of CG make/equivalent. | Nos | 15991.36 | 15991.36 | 2.0 | False | None | None | False | None | False | 31982.72 | 0 |
| 3566440 | 129356 | None | code367 | Supplying and fixing of LED Bulk head of 10W with IP65 protection and IK08 impact resistance suitable for surface and wall mounting applications. LBHE-10-CDL of CG make/equivalent. | Nos | 1043.24 | 1043.24 | 21.0 | False | None | None | False | None | False | 21908.04 | 0 |
| 3566441 | 129356 | None | code368 | Fixing all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling/ rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafter / girders | Nos | 151.16 | 151.16 | 299.0 | False | None | None | False | None | False | 45196.84 | 0 |
| 3566442 | 129356 | None | code369 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, and 50 cycles. Single phase AC supply conforming to IS-374-1979 and with double ball bearing system and as per technical data approved. 48" sweep (1200mm) regular model | Nos | 3697.18 | 3697.18 | 34.0 | False | None | None | False | None | False | 125704.12 | 0 |
| 3566443 | 129356 | None | code370 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, and 50 cycles. Single phase AC supply conforming to IS-374-1979 and with double ball bearing system and as per technical data approved. 36" sweep (900mm) economy model | Each | 2712.82 | 2712.82 | 4.0 | False | None | None | False | None | False | 10851.28 | 0 |
| 3566444 | 129356 | None | code371 | Fixing a ceiling fan of all capacities and all types with necessary clamps & S hook made out of 15mm dia MS rod, with 5 amps ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wodden board and wired complete. | Nos | 390.29 | 390.29 | 38.0 | False | None | None | False | None | False | 14831.02 | 0 |
| 3566445 | 129356 | None | code372 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable for operate on 230V 50Hz, AC Supply. | Nos | 1848.59 | 1848.59 | 14.0 | False | None | None | False | None | False | 25880.26 | 0 |
| 3566446 | 129356 | None | code373 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make. | Nos | 609.59 | 609.59 | 17.0 | False | None | None | False | None | False | 10363.03 | 0 |
| 3566447 | 129356 | None | code374 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 15" Sweep (450 mm) | Nos | 5508.59 | 5508.59 | 3.0 | False | None | None | False | None | False | 16525.77 | 0 |
| 3566448 | 129356 | None | code375 | Earthing system :
Supplying, fixing and wiring earth electrode for grounding of computers, Lifts, Transformers, DG sets etc., Using 40 mm dia 2.9mm thick 2.5mtrs long with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a C.C. chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covereed 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Nos | 5273.18 | 5273.18 | 6.0 | False | None | None | False | None | False | 31639.08 | 0 |
| 3566449 | 129356 | None | code376 | Supplying and running of GI strips for grounding connections, using necessary fixing materials as required - 25x6mm GI strip | m | 158.59 | 158.59 | 50.0 | False | None | None | False | None | False | 7929.5 | 0 |
| 3566450 | 129356 | None | code377 | Supplying and running of GI strips for grounding connections, using necessary fixing materials as required - 25x3mm GI strip | m | 101.6 | 101.6 | 80.0 | False | None | None | False | None | False | 8128.0 | 0 |
| 3566451 | 129356 | None | code378 | 8 SWG, GI Wire | m | 23.54 | 23.54 | 100.0 | False | None | None | False | None | False | 2354.0 | 0 |
| 3566452 | 129356 | None | code379 | TELEPHONE SYSTEM : Supplying and fixing of modular switch/ Socket / telephone socket etc., on existing modular switch plate as per IS 3854 and IS 1293. - Telephone socket | Nos | 193.28 | 193.28 | 10.0 | False | None | None | False | None | False | 1932.8 | 0 |
| 3566453 | 129356 | None | code380 | Supplying & drawing PVC flexible 2 pair telephone unarmoured tinned copper cable. | m | 26.02 | 26.02 | 270.0 | False | None | None | False | None | False | 7025.4 | 0 |
| 3566454 | 129356 | None | code381 | Supplying & Laying of 2mm thick, heavy guage PVC conduit pipe in the concealed slab / groove cutting with suitable size bends, collars, clamps, metal junction boxes adhesive paste etc., and running before concreting the slabs. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes, and pipe ends should be covered using PVC end closures and run with 18 SWG G.I fish wire run throughout the conduit wherever necessary - 20mm dia PVC Conduit - Supplying & laying | m | 83.01 | 83.01 | 200.0 | False | None | None | False | None | False | 16602.0 | 0 |
| 3566455 | 129356 | None | code382 | Supplying & installing of multicore 0.61mm, copper conductor, PVC insulated, PVC sheathed, armoured telephone cable laid drawn through,existing conduit with all necessary accessories as required. 5 pair cable - Supplying & laying | m | 157.06 | 157.06 | 500.0 | False | None | None | False | None | False | 78530.0 | 0 |
| 3566456 | 129356 | None | code383 | 10 pair cable - Supplying & laying | m | 195.61 | 195.61 | 450.0 | False | None | None | False | None | False | 88024.5 | 0 |
| 3566457 | 129356 | None | code384 | Supplying and fixing of MDF krone juntion box with KRONE module / Telephone cable termination.- 5 pair - Supplying & Fixing | Nos | 356.95 | 356.95 | 1.0 | False | None | None | False | None | False | 356.95 | 0 |
| 3566458 | 129356 | None | code385 | 10 pair - Supplying & Fixing | Nos | 489.41 | 489.41 | 1.0 | False | None | None | False | None | False | 489.41 | 0 |
| 3566459 | 129356 | None | code386 | 2 DATA SYSTEM :Supplying & Laying of 2mm thick, heavy guage PVC conduit pipe in the concealed slab / groove cutting with suitable size bends, collars, clamps, metal junction boxes adhesive paste etc., and running before concreting the slabs. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes, and pipe ends should be covered using PVC end closures and run with 18 SWG G.I fish wire run throughout the conduit wherever necessary - 20mm dia PVC Conduit - Supplying & laying | m | 83.01 | 83.01 | 20.0 | False | None | None | False | None | False | 1660.2 | 0 |
| 3566460 | 129356 | None | code387 | 25mm dia PVC Conduit - Supplying & laying | m | 97.26 | 97.26 | 80.0 | False | None | None | False | None | False | 7780.8 | 0 |
| 3566461 | 129356 | None | code388 | Supplying and fixing of modular Socket on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O outlet | Nos | 417.54 | 417.54 | 8.0 | False | None | None | False | None | False | 3340.32 | 0 |
| 3566462 | 129356 | None | code389 | Supplying and drawing UTP -CAT 6E LAN cable | m | 47.08 | 47.08 | 150.0 | False | None | None | False | None | False | 7062.0 | 0 |
| 3566463 | 129356 | None | code390 | Supply, installation , testing & commissioning of managed L2 10 port switch of 10/100/1000 Mbps with 2 Gig SFP. The switch shall be mounted on existing rack. The rate shall also include cost of power supply and providing end termination. | Nos | 25027.8 | 25027.8 | 1.0 | False | None | None | False | None | False | 25027.8 | 0 |
| 3566464 | 129356 | None | code391 | Supply and fixing of patch panel with CAT-6 I/O mounted on existing rack with all necessary fixing accessories. The rate shall also include providing end termination. 24 port 10/100/1000 patch panel | Nos | 9788.1 | 9788.1 | 1.0 | False | None | None | False | None | False | 9788.1 | 0 |
| 3566465 | 129356 | None | code392 | Supply, installation , testing & commissioning of SFP Transceiver 1000BASE-LR SINGLE MODE LC GBIC | Nos | 22844.8 | 22844.8 | 2.0 | False | None | None | False | None | False | 45689.6 | 0 |
| 3566466 | 129356 | None | code393 | Supply and fixing of …mtrs cat 6 patch cable- 1 mtr | m | 277.54 | 277.54 | 8.0 | False | None | None | False | None | False | 2220.32 | 0 |
| 3566467 | 129356 | None | code394 | Supply and fixing of …mtrs cat 6 patch cable- 2 mtr | m | 318.42 | 318.42 | 8.0 | False | None | None | False | None | False | 2547.36 | 0 |
| 3566468 | 129356 | None | code395 | OS2 SC-LC single mode duplex fiber optic Patch Cord 3Mtrs | Nos | 3355.33 | 3355.33 | 2.0 | False | None | None | False | None | False | 6710.66 | 0 |
| 3566469 | 129356 | None | code396 | Supply and installation of rack mount LIU loaded with couplers and all necessary accessories. -6 fibre SC style single mode Fiber Panel loaded with Splice Tray, Adapters & Pigtails- 1U | Nos | 9994.6 | 9994.6 | 1.0 | False | None | None | False | None | False | 9994.6 | 0 |
| 3566470 | 129356 | None | code397 | Supply, laying and testing of Optical fiber cable, the rate shall include the cost of joint enclosure and splicing of Optical Fiber cables. - 6 Core single mode OS2 corrugated steel tape armoured loose tube gell- filled, 9/125 micron fiber optic cable. | m | 104.23 | 104.23 | 450.0 | False | None | None | False | None | False | 46903.5 | 0 |
| 3566471 | 129356 | None | code398 | Supply and fixing of switch wall mounting closed rack with power manager and cable manager - 12U with 450mm depth with all necrssary accessories as required. | Nos | 20397.66 | 20397.66 | 1.0 | False | None | None | False | None | False | 20397.66 | 0 |
| 3566472 | 129356 | None | code399 | IP CCTV SYSTEM
Supplying & Laying of 2mm thick, heavy guage PVC conduit pipe in the concealed slab / groove cutting with suitable size bends, collars, clamps, metal junction boxes adhesive paste etc., and running before concreting the slabs. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes, and pipe ends should be covered using PVC end closures and run with 14 SWG G.I fish wire run throughout the conduit wherever necessary - 20mm dia PVC Conduit - Supplying & laying | m | 83.01 | 83.01 | 80.0 | False | None | None | False | None | False | 6640.8 | 0 |
| 3566473 | 129356 | None | code400 | 25mm dia PVC Conduit - Supplying & laying | m | 97.26 | 97.26 | 350.0 | False | None | None | False | None | False | 34041.0 | 0 |
| 3566474 | 129356 | None | code401 | Supplying, drawing and connecting of 1 pair E - Cat-6 cable in 25mm dia PVC conduit with all other accessories. | m | 47.08 | 47.08 | 800.0 | False | None | None | False | None | False | 37664.0 | 0 |
| 3566475 | 129356 | None | code402 | Supply, installation, testing and commissioning of outdoor 2.0MP IP IR Bullet WDR, 2.7-12mm varifocal Color Camera, 1/3" CMOS, H.264/MJPEG High-profile, dual Stream support, True Day & Night (TDN) with , Wide Dynamic Range (WDR), Open Network Video Interface Forum (ONVIF) Profile S & G - TF card support (128 GB), IP66 Rating, Power Over Ethernet (POE), IR distance upto 30 Meter depending on scene reflectance. | Nos | 8177.4 | 8177.4 | 4.0 | False | None | None | False | None | False | 32709.6 | 0 |
| 3566476 | 129356 | None | code403 | Supply, installation, testing and commissioning of outdoor 2.0MP IP IR Minidome, WDR, 2.7-12mm varifocal Color dome Camera, 1/3" CMOS, H.264/MJPEG High-profile, dual Stream support, True Day & Night (TDN) with , Wide Dynamic Range (WDR), Open Network Video Interface Forum (ONVIF) Profile S & G - TF card support (128 GB), IP66 & IK 10 Rating, Power Over Ethernet (POE), IR distance upto 30 Meter depending on scene reflectance. | Nos | 8177.4 | 8177.4 | 21.0 | False | None | None | False | None | False | 171725.4 | 0 |
| 3566477 | 129356 | None | code404 | Supply, installation , testing & commissioning of managed L2 12 port POE switch of 10/100/1000 Mbps with 2 Gig SFP. & power budget of min. 170W. The switch shall be mounted on existing rack. The rate shall also include cost of power supply and providing end termination. | Nos | 59253.7 | 59253.7 | 2.0 | False | None | None | False | None | False | 118507.4 | 0 |
| 3566478 | 129356 | None | code405 | Supply and fixing of patch panel with CAT-6 I/O mounted on existing rack with all necessary fixing accessories. The rate shall also include providing end termination. - 24 port 10/100/1000 jack panel | Nos | 9788.1 | 9788.1 | 1.0 | False | None | None | False | None | False | 9788.1 | 0 |
| 3566479 | 129356 | None | code406 | Supply and fixing of …mtrs cat 6 patch cable- 1 mtr | m | 277.54 | 277.54 | 25.0 | False | None | None | False | None | False | 6938.5 | 0 |
| 3566480 | 129356 | None | code407 | MISCELLANEOUS WORKS: Supply & laying of 2 mm thick, PVC conduit with all conduit accessories etc., as required. The rate shall include chasing of walls / floors and plastering the chased portion as required 20mm dia PVC Conduit | m | 83.01 | 83.01 | 100.0 | False | None | None | False | None | False | 8301.0 | 0 |
| 3566481 | 129356 | None | code408 | 25mm dia PVC Conduit | m | 97.26 | 97.26 | 100.0 | False | None | None | False | None | False | 9726.0 | 0 |
| 3566482 | 129356 | None | code409 | 32mm dia PVC Conduit | m | 125.14 | 125.14 | 50.0 | False | None | None | False | None | False | 6257.0 | 0 |
| 3566483 | 129356 | None | code410 | Supply and fixing of MS support made out of Mild steel of adequate size suitable supporting for cable trays, cables, conduits. The supports shall be ceiling suspended type / wall bracket type clamps with necessary accessories for fixing of cable trays, cables, conduits as per site requirement. The supports shall be provided at every 1.5 M span and at bends / crossings. The painting for MS frame work with two coats of enamel paint of approved colour over a coat of premier. The contractor shall submit the GA drg for typical supports and on obtaining the approval from Architect/Consultants. | Kgs | 140.01 | 140.01 | 100.0 | False | None | None | False | None | False | 14001.0 | 0 |
| 3566484 | 129356 | None | code411 | D FIRE FIGHTING & RELATED WORKS :
PUMP ROOM : Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering,adequate LPM at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories,neoprine gaskets (16 kg/sq.cm) Control panel is excluded.Required GA drawingfor the pump/ foundation shall be submitted by the contractor. (2850 lpm at 70m head) | Nos | 415065.0 | 415065.0 | 2.0 | False | None | None | False | None | False | 830130.0 | 0 |
| 3566485 | 129356 | None | code412 | Supply, installation, testing & commissioning of diesel engine driven pump, horizontal mounted, Horizontal spiltcase centrifugal single stage pump, capable of delivering required flow at required head when running at 1800 RPM with adequate BHP automatic diesel engine driven pumpset having the residential silencer system and other accessories like fuel tank, necessary radiator cooling system, flanges, neoprene gaskets (16.0 kg/sqcm), 200 litres fuel storage tank with piping, valves as per detailed specification and two separate starting mechanisms (automatic starting by battery power, electric starting motor as well as manual starting by electric start motor) common bed plate with anti vibration pads, necessary foundation, foundation bolts etc., complete in all respects as per the detailed specifdication. Control panel excluded. Required GA drawingfor the pump shall be submitted by the contractor. Required GA drawingfor the pump/ foundation shall be
submitted by the contractor.(2850 lpm at 70m head) | Nos | 786765.0 | 786765.0 | 1.0 | False | None | None | False | None | False | 786765.0 | 0 |
| 3566486 | 129356 | None | code413 | Supply, Installation, testing and commisioning electrically driven jockey pump of capacity 180.0 Lpm at required head end suction type bronze impeller pump oupled to electrical driven motor with suitable HP with all the necessary accessories, operating on 3Ph 50Hz, 400/440 V AC supply including foundation, foundation bolts, anti vibration pad,etc. complete. Including cost of materials, labour, usage charges of machinery complete as per specifications. Control panle is excluded. Required GA drawingfor thepump/ foundation shall be submitted by the contractor.(180 lpm at 70m head) | Nos | 105315.0 | 105315.0 | 2.0 | False | None | None | False | None | False | 210630.0 | 0 |
| 3566487 | 129356 | None | code414 | Supplying Installing testing and commissiong COMMON Control panel for fire fighting system consiting of electrical motor driven 60HP Main fire pump, Diesel engine driven pump 60 HP Sprinkler pump 50HP & Jockey pump 25HP | Unit | 344442.0 | 344442.0 | 1.0 | False | None | None | False | None | False | 344442.0 | 0 |
| 3566488 | 129356 | None | code415 | Supplying, Installing testing & commissioning approved make Centrifugal pump end suction type coupled to Electric motor of suitable HP, fitted on a commonbase frame and rated for Fire duty. The quated price shall aslo include 2 Nos. Pressure guages fitted on suction & delivery sides of the pump. The pumps shall run on 400/440V 3 ph. 50 Hz electric supply. Duty of pumps: 900 Lpm @ 35.0m Head. Control panel shall be as specified in item no, 87, including cost of materials, labour, usage charges of machinery complete as per specifications. | Nos | 111510.0 | 111510.0 | 1.0 | False | None | None | False | None | False | 111510.0 | 0 |
| 3566489 | 129356 | None | code416 | Supplying Installing testing and commission of Electrical Booster pump Control panel for fire fighting system consisting of Feeder For 1 No. of Booster pumps :-1 no of 32 A TPN MCCB (50 KA with 12.5 HP DOL starter with over load relay, single phase preventer ON / OFF push buttons. 1 No. Auto manual selector switch. 1 set of RYB indicating lamps with individual HRC Control Fuses 1 set of RYB indicating lamps with individual HRC Control Fuses 1 no 16 sq.mm 0-800Amps. Ammeter with selector switch and Suitable rated current transformers 1 No.0-800 96 sq. mm
Voltmeter and selector Switch | Unit | 43365.0 | 43365.0 | 1.0 | False | None | None | False | None | False | 43365.0 | 0 |
| 3566490 | 129356 | None | code417 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 200mm dia | Each | 19824.0 | 19824.0 | 6.0 | False | None | None | False | None | False | 118944.0 | 0 |
| 3566491 | 129356 | None | code418 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 150mm dia | Nos | 15487.5 | 15487.5 | 6.0 | False | None | None | False | None | False | 92925.0 | 0 |
| 3566492 | 129356 | None | code419 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 100mm dia | Nos | 11151.0 | 11151.0 | 5.0 | False | None | None | False | None | False | 55755.0 | 0 |
| 3566493 | 129356 | None | code420 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 80mm dia | Nos | 8673.0 | 8673.0 | 2.0 | False | None | None | False | None | False | 17346.0 | 0 |
| 3566494 | 129356 | None | code421 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :200 mm dia | Nos | 17346.0 | 17346.0 | 1.0 | False | None | None | False | None | False | 17346.0 | 0 |
| 3566495 | 129356 | None | code422 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia | Nos | 14248.5 | 14248.5 | 7.0 | False | None | None | False | None | False | 99739.5 | 0 |
| 3566496 | 129356 | None | code423 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia | Nos | 8821.68 | 8821.68 | 5.0 | False | None | None | False | None | False | 44108.4 | 0 |
| 3566497 | 129356 | None | code424 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia | Nos | 6814.5 | 6814.5 | 2.0 | False | None | None | False | None | False | 13629.0 | 0 |
| 3566498 | 129356 | None | code425 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia
holes with stainless steel flange.200mm dia | Nos | 30355.5 | 30355.5 | 2.0 | False | None | None | False | None | False | 60711.0 | 0 |
| 3566499 | 129356 | None | code426 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia
holes with stainless steel flange.100mm dia | Nos | 15351.21 | 15351.21 | 3.0 | False | None | None | False | None | False | 46053.63 | 0 |
| 3566500 | 129356 | None | code427 | Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain
arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade
as required. | Nos | 37170.0 | 37170.0 | 1.0 | False | None | None | False | None | False | 37170.0 | 0 |
| 3566501 | 129356 | None | code428 | Supply, installing, diesel tank for diese engine 200lit cap | Nos | 31152.0 | 31152.0 | 1.0 | False | None | None | False | None | False | 31152.0 | 0 |
| 3566502 | 129356 | None | code429 | Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. | Nos | 3593.1 | 3593.1 | 5.0 | False | None | None | False | None | False | 17965.5 | 0 |
| 3566503 | 129356 | None | code430 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. | Nos | 2416.05 | 2416.05 | 6.0 | False | None | None | False | None | False | 14496.3 | 0 |
| 3566504 | 129356 | None | code431 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 182.13 | 182.13 | 650.0 | False | None | None | False | None | False | 118384.5 | 0 |
| 3566505 | 129356 | None | code432 | 3 Core x 1.5Sqmm for Pressure Switch | m | 89.21 | 89.21 | 120.0 | False | None | None | False | None | False | 10705.2 | 0 |
| 3566506 | 129356 | None | code433 | Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. (150 AH capacity) | Nos | 34923.69 | 34923.69 | 1.0 | False | None | None | False | None | False | 34923.69 | 0 |
| 3566507 | 129356 | None | code434 | Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. | m | 962.7 | 962.7 | 80.0 | False | None | None | False | None | False | 77016.0 | 0 |
| 3566508 | 129356 | None | code435 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 1858.5 | 1858.5 | 1.0 | False | None | None | False | None | False | 1858.5 | 0 |
| 3566509 | 129356 | None | code436 | SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Nos | 1486.8 | 1486.8 | 10.0 | False | None | None | False | None | False | 14868.0 | 0 |
| 3566510 | 129356 | None | code437 | SITC of Gun metal BALL VALVE SIZE OF 19/20 mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Nos | 1177.05 | 1177.05 | 10.0 | False | None | None | False | None | False | 11770.5 | 0 |
| 3566511 | 129356 | None | code438 | Fire Hydrant & Sprinkler System : Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. : 200 mm dia | m | 5327.7 | 5327.7 | 100.0 | False | None | None | False | None | False | 532770.0 | 0 |
| 3566512 | 129356 | None | code439 | 150 mm dia | m | 4832.1 | 4832.1 | 2200.0 | False | None | None | False | None | False | 10630620.0 | 0 |
| 3566513 | 129356 | None | code440 | 100 mm dia | m | 3531.15 | 3531.15 | 1700.0 | False | None | None | False | None | False | 6002955.0 | 0 |
| 3566514 | 129356 | None | code441 | 80 mm dia | m | 2849.7 | 2849.7 | 650.0 | False | None | None | False | None | False | 1852305.0 | 0 |
| 3566515 | 129356 | None | code442 | 65 mm dia | m | 2106.3 | 2106.3 | 600.0 | False | None | None | False | None | False | 1263780.0 | 0 |
| 3566516 | 129356 | None | code443 | 50 mm dia | m | 1610.7 | 1610.7 | 700.0 | False | None | None | False | None | False | 1127490.0 | 0 |
| 3566517 | 129356 | None | code444 | 40 mm dia | m | 1300.95 | 1300.95 | 900.0 | False | None | None | False | None | False | 1170855.0 | 0 |
| 3566518 | 129356 | None | code445 | 32 mm dia | m | 991.2 | 991.2 | 1200.0 | False | None | None | False | None | False | 1189440.0 | 0 |
| 3566519 | 129356 | None | code446 | 25 mm dia | m | 867.3 | 867.3 | 4000.0 | False | None | None | False | None | False | 3469200.0 | 0 |
| 3566520 | 129356 | None | code447 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia | m | 495.6 | 495.6 | 1120.0 | False | None | None | False | None | False | 555072.0 | 0 |
| 3566521 | 129356 | None | code448 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia | m | 309.75 | 309.75 | 280.0 | False | None | None | False | None | False | 86730.0 | 0 |
| 3566522 | 129356 | None | code449 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 150mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Nos | 15487.5 | 15487.5 | 30.0 | False | None | None | False | None | False | 464625.0 | 0 |
| 3566523 | 129356 | None | code450 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 100mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Nos | 11151.0 | 11151.0 | 38.0 | False | None | None | False | None | False | 423738.0 | 0 |
| 3566524 | 129356 | None | code451 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Nos | 5575.5 | 5575.5 | 37.0 | False | None | None | False | None | False | 206293.5 | 0 |
| 3566525 | 129356 | None | code452 | Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.150mm dia | Each | 11177.02 | 11177.02 | 37.0 | False | None | None | False | None | False | 413549.74 | 0 |
| 3566526 | 129356 | None | code453 | Providing, fixing, testing & commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm andhydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia | Each | 86730.0 | 86730.0 | 6.0 | False | None | None | False | None | False | 520380.0 | 0 |
| 3566527 | 129356 | None | code454 | Supplying Installing, testing and commissioning of 150mm dia 4 way Fire brigade inlet connection with Non retrn valve of 4 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. | Nos | 47082.0 | 47082.0 | 3.0 | False | None | None | False | None | False | 141246.0 | 0 |
| 3566528 | 129356 | None | code455 | Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. | Nos | 40887.0 | 40887.0 | 1.0 | False | None | None | False | None | False | 40887.0 | 0 |
| 3566529 | 129356 | None | code456 | FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Nos | 13009.5 | 13009.5 | 78.0 | False | None | None | False | None | False | 1014741.0 | 0 |
| 3566530 | 129356 | None | code457 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 6195.0 | 6195.0 | 156.0 | False | None | None | False | None | False | 966420.0 | 0 |
| 3566531 | 129356 | None | code458 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. | Each | 5575.5 | 5575.5 | 78.0 | False | None | None | False | None | False | 434889.0 | 0 |
| 3566532 | 129356 | None | code459 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size
20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 8053.5 | 8053.5 | 46.0 | False | None | None | False | None | False | 370461.0 | 0 |
| 3566533 | 129356 | None | code460 | Supplying and fixing of Fire duct Shutter fabricated out of M.S.sheet and frame, door shall befixed with 4 mm thick Glass, suitable Rubber beading and Locking arrangement. Rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside and
outside | Sqm | 15487.5 | 15487.5 | 35.0 | False | None | None | False | None | False | 542062.5 | 0 |
| 3566534 | 129356 | None | code461 | Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 degree swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 6442.8 | 6442.8 | 37.0 | False | None | None | False | None | False | 238383.6 | 0 |
| 3566535 | 129356 | None | code462 | Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications | Each | 7434.0 | 7434.0 | 37.0 | False | None | None | False | None | False | 275058.0 | 0 |
| 3566536 | 129356 | None | code463 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 1858.5 | 1858.5 | 24.0 | False | None | None | False | None | False | 44604.0 | 0 |
| 3566537 | 129356 | None | code464 | SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Nos | 1486.8 | 1486.8 | 60.0 | False | None | None | False | None | False | 89208.0 | 0 |
| 3566538 | 129356 | None | code465 | Providing of core cutting 50mm to 200mm dia Including all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and convene of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer - in charge of this work. | Nos | 2596.0 | 2596.0 | 200.0 | False | None | None | False | None | False | 519200.0 | 0 |
| 3566539 | 129356 | None | code466 | Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/wall mounted type designed to operate 68 degrees centegrad Make Tyco/HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 degre COrange, 68 degree C - Red, 79 degree C - Yellow, 93 degree C - Green, 141 degree C - Blue, 182 degree C Mauve, 227/260 degree C - Black) | Each | 464.63 | 464.63 | 3500.0 | False | None | None | False | None | False | 1626205.0 | 0 |
| 3566540 | 129356 | None | code467 | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work : Socket Elbow 25/15 | Nos | 259.6 | 259.6 | 1600.0 | False | None | None | False | None | False | 415360.0 | 0 |
| 3566541 | 129356 | None | code468 | Socket Elbow 25/25 | Nos | 259.6 | 259.6 | 100.0 | False | None | None | False | None | False | 25960.0 | 0 |
| 3566542 | 129356 | None | code469 | Socket Tee 25/15/25 | Nos | 330.4 | 330.4 | 30.0 | False | None | None | False | None | False | 9912.0 | 0 |
| 3566543 | 129356 | None | code470 | Socket Tee 32/15/32 | Nos | 448.4 | 448.4 | 250.0 | False | None | None | False | None | False | 112100.0 | 0 |
| 3566544 | 129356 | None | code471 | Socket Tee 40/15/40 | Nos | 566.4 | 566.4 | 400.0 | False | None | None | False | None | False | 226560.0 | 0 |
| 3566545 | 129356 | None | code472 | Forged Collar 25/15 | Nos | 165.2 | 165.2 | 1500.0 | False | None | None | False | None | False | 247800.0 | 0 |
| 3566546 | 129356 | None | code473 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 182.13 | 182.13 | 1600.0 | False | None | None | False | None | False | 291408.0 | 0 |
| 3566547 | 129356 | None | code474 | FIRE EXTINGUSHERS & SIGN BOARD : Providing Aqueous Film-Forming Foam - 9 Ltr
Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 10035.9 | 10035.9 | 2.0 | False | None | None | False | None | False | 20071.8 | 0 |
| 3566548 | 129356 | None | code475 | Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 8053.5 | 8053.5 | 20.0 | False | None | None | False | None | False | 161070.0 | 0 |
| 3566549 | 129356 | None | code476 | Providing Water Mist 4 Kg CO2 Gas Type Fire Extinguisher, used Unused Mechanism, Squeeze Grip , Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 600MM Diameter 108MM, Discharge Time less than 8 Secs, Controllable discharge mechanism, Applicable on Class B&C Fire, B Rating 13B, Can Constructing : Hot spinning/Forging, Value Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.0MM ISI Approved, 1 Year Warranty. ---- With all Lead & Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work | Each | 12331.0 | 12331.0 | 30.0 | False | None | None | False | None | False | 369930.0 | 0 |
| 3566550 | 129356 | None | code477 | Supplying of two bucket stand alongwith buckets. complete | Each | 1362.9 | 1362.9 | 20.0 | False | None | None | False | None | False | 27258.0 | 0 |
| 3566551 | 129356 | None | code478 | Providing and fixing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.Providing and fixing in position the signages "FIRE ORDER" it should contain the following text on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3' x 4'.A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS.
C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.
D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. | Each | 3097.5 | 3097.5 | 30.0 | False | None | None | False | None | False | 92925.0 | 0 |
| 3566552 | 129356 | None | code479 | ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS (Current phone numbers to be provided in this location by the contractor)
C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER (Current phone numbers to be provided in this location by the contractor) F) FIRE FIGHTING AGENCY PHONE (Current phone numbers to be provided in this location by the contractor) FAX (Current fax numbers to be provided in this location by the contractor) | m | 3097.5 | 3097.5 | 30.0 | False | None | None | False | None | False | 92925.0 | 0 |
| 3566553 | 129356 | None | code480 | Providing's Escape Signage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(route plan Fire Escape Route Plan A2 Size) | Sqm | 24814.58 | 24814.58 | 7.48 | False | None | None | False | None | False | 185613.0584 | 0 |
| 3566554 | 129356 | None | code481 | TWO WAY TACK BACK & PA SYSTEM : Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth ---- including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work | Nos | 64251.0 | 64251.0 | 3.0 | False | None | None | False | None | False | 192753.0 | 0 |
| 3566555 | 129356 | None | code482 | Supplying Installing, testing and commissioning of MIKE | Each | 6814.5 | 6814.5 | 5.0 | False | None | None | False | None | False | 34072.5 | 0 |
| 3566556 | 129356 | None | code483 | Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 3035.55 | 3035.55 | 32.0 | False | None | None | False | None | False | 97137.6 | 0 |
| 3566557 | 129356 | None | code484 | FIRE ALARM SYSTEM : Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc | Each | 604160.0 | 604160.0 | 3.0 | False | None | None | False | None | False | 1812480.0 | 0 |
| 3566558 | 129356 | None | code485 | Supply, Installation , Testing & Commissioning of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked. Approval: UL/VDS/EN54. Make: | Each | 80535.0 | 80535.0 | 3.0 | False | None | None | False | None | False | 241605.0 | 0 |
| 3566559 | 129356 | None | code486 | Supply, intallation, testing and Commissioning of loop card ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Each | 54870.0 | 54870.0 | 3.0 | False | None | None | False | None | False | 164610.0 | 0 |
| 3566560 | 129356 | None | code487 | Supply, installation, testing and commissioning of analogue addressable Smoke Sensor detector and standard base (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each
detector/device) Approval: VDS/UL/EN54. | Each | 4088.7 | 4088.7 | 360.0 | False | None | None | False | None | False | 1471932.0 | 0 |
| 3566561 | 129356 | None | code488 | Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10 C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier,Argus(Uk) | Each | 6071.1 | 6071.1 | 47.0 | False | None | None | False | None | False | 285341.7 | 0 |
| 3566562 | 129356 | None | code489 | Supplying and fixing sheet Metal box made out of 18 SWG
sheet metal with necessary holes for cable/conduit entry as
required with one coat of primer of approved make etc.100 x 75 x 65 mm | Each | 146.2 | 146.2 | 1150.0 | False | None | None | False | None | False | 168130.0 | 0 |
| 3566563 | 129356 | None | code490 | PUBLIC ADDRESS SYSTEM : Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 480 watt amplifire, 1 No. 10 zone console and 1 no Mike and in built electronic connections circuits. ---- including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work | Each | 64900.0 | 64900.0 | 4.0 | False | None | None | False | None | False | 259600.0 | 0 |
| 3566564 | 129356 | None | code491 | E LIFT / HOIST & EXTERNAL LIGHT POLES & FITTINGS WORKS GOODS LIFT MAIN DAIRY BLOCK Capacity-1500 Kgs. Levels - 3 Shaft Way Size 2400 mm Width x 3125mm Depth Size of the carriage - 1.8/1.5 Mtrs x 2.0/2.3 Mtrs or as per manufacturers standard design etc.. complete as per specifications Type Goods /Freight Lift Capacity of Goods Lift 1500Kgs Shaft Way Size 2400 mm Width x 3125mm Depth Size of the carriage Minimum 1.8/1.5 Mtrs x 2.0/2.3 Mtrs or as per manufacturers standard design /as per shaft size and capacity of lift - bidder should clearly specify in their tender compliance Door opening Minimum 1.4 Mtrs , center /side opening automatic or as per manufacturers standard design to suit site requirements/conditions /material handling equipment movements - bidder should clearly specify in their tender compliance Levels /stops 2 Levels /stops Ground floor at 0 mtr level First floor at 4.5/6 Mtr level Second floor at 9/12 Mtr level Lift Height/Travel 12 Mtrs or as per civil Building size- bidder should clearly specify in their tender compliance Minimum Lift Height As per manufacturers standard design Speed Minimum 0.75-1 Mtrs per second - as per manufacturers standard design.- bidder should clearly specify in their tender compliance Machine Room Location At the Top of the lift shaft Power supply - 415 + 10 %V, 3 Phase, 50 Hz, AC as specified in the specs Type of Drive-Geared or gearless with M/C Room as specified in the technical specifications. bidder should clearly specify in their tender compliance Input panel for lift comprising ELCB/RCCB, MCB, RYB indication lamps, volts, amps meters with input, output terminals and housing etc for Lift Make Of Goods Lift- OTIS/KONE/THYSSEN KRUPP/RASHI /JHONSON /COMFORT/TK Elevator All other data as specified in the technical specifications | Each | 4233840.0 | 4233840.0 | 1.0 | False | None | None | False | None | False | 4233840.0 | 0 |
| 3566565 | 129356 | None | code492 | GOODS LIFT : MAIN DAIRY BLOCK Capacity-1500 Kgs. Levels - 3 Shaft Way Size 2400 mm Width x 3125mm Depth Size of the carriage - 1.8/1.5 Mtrs x 2.0/2.3 Mtrs or as per manufacturers standard design etc.. complete as per specifications Type Goods /Freight Lift Capacity of Goods Lift 1500Kgs Shaft Way Size 2400 mm Width x 3125mm Depth Size of the carriage Minimum 1.8/1.5 Mtrs x 2.0/2.3 Mtrs or as per manufacturers standard design /as per shaft size and capacity of lift - bidder should clearly specify in their tender compliance Door opening Minimum 1.4 Mtrs , center /side opening automatic or as per manufacturers standard design to suit site requirements/conditions /material handling equipment movements - bidder should clearly specify in their tender compliance Levels /stops 2 Levels /stops Ground floor at 0 mtr level First floor at 4.5/6 Mtr level Second floor at 9/12 Mtr level Lift Height/Travel 12 Mtrs or as per civil Building size- bidder should clearly specify in their tender compliance Minimum Lift Height As per manufacturers standard design Speed Minimum 0.75-1 Mtrs per second - as per manufacturers standard design.- bidder should clearly specify in their tender compliance Machine Room Location At the Top of the lift shaft Power supply - 415 + 10 %V, 3 Phase, 50 Hz, AC as specified in the specs Type of Drive-Geared or gearless with M/C Room as specified in the technical specifications. bidder should clearly specify in their tender compliance Input panel for lift comprising ELCB/RCCB, MCB, RYB indication lamps, volts, amps meters with input, output terminals and housing etc for Lift Make Of Goods Lift- OTIS/KONE/THYSSEN KRUPP/RASHI /JHONSON /COMFORT/TK Elevator All other data as specified in the technical specifications | Each | 4491670.0 | 4491670.0 | 1.0 | False | None | None | False | None | False | 4491670.0 | 0 |
| 3566566 | 129356 | None | code493 | GOODS LIFT : POWDER PLANT BLOCK Capacity-1500 Kgs. Levels - 8
Shaft Way Size 1900 mm Width x 2000 mm Depth Size of the carriage - 1.5Mtrs x 1.4 Mtrs or as per manufacturers standard design .. complete as per specifications type Goods /Freight Lift Capacity of Goods Lift 1500Kgs Shaft Way Size 1900 mm Width x 2000mm Depth Size of the carriage Minimum 1.5Mtrs x 1.4 Mtrs or as per manufacturers standard design /as per shaft size- bidder should clearly specify in their tender compliance Door opening Minimum 1.0 Mtrs , center /side opening automatic or as per manufacturers standard design to suit site requirements/conditions /material handling equipment movements - bidder should clearly specify in their tender compliance Levels /stops 8 Levels /stops Ground floor at 0 mtr level Floor at 5 Mtr level, Floor at 11.5 Mtr level, Floor at 15.5 Mtr level Floor at 19 Mtr level, Floor at 23 Mtr level, Floor at 29.8 Mtr level Floor at 34.9 Mtr level Lift Height/Travel 35 Mtrs or as per civil Building size- bidder should clearly specify in their tender compliance Minimum Lift Height As per manufacturers standard design Speed 0.75-1 Mtrs per second - as per manufacturers standard design. bidder should clearly specify in their tender complianceMachine Room Location At the Top of the lift shaft Power supply 415 + 10 %V, 3 Phase, 50 Hz, AC as specified in the specs Type of Drive Geared or gearless with M/C Room as specified in the technical specifications. bidder should clearly specify in their tender compliance Make Of Goods Lift Input panel for lift comprising ELCB/RCCB, MCB, RYB indication lamps, volts, amps meters with input, output terminals and housing etc for Lift OTIS/KONE/THYSSEN KRUPP/RASHI /JHONSON /COMFORT/TK Elevator All other data as specified in the technical specifications | Each | 5224450.0 | 5224450.0 | 1.0 | False | None | None | False | None | False | 5224450.0 | 0 |
| 3566567 | 129356 | None | code494 | PASSENGER LIFT : POWDER PLANT Capacity-8 Persons. Levels - 8
complete as per specifications Type Passenger Lift Capacity of Lift 8 persons Shaft Way Size 1900 mm Width x 2000mm Depth Size of the carriage Minimum 1300/1400mm width x 1100/1000mm Depth or As per manufacturers standard design to suit the shaft size, Capacity etc.. - bidder should clearly specify in their tender compliance Door opening Minimum 800mm, center opening automatic type or as per manufacturers standard design to suit site requirements /conditions bidder should clearly specify in their tender compliance Levels /stops 8 Levels /stops Ground floor at 0 mtr level Floor at 5 Mtr level, Floor at 11.5 Mtr level, Floor at 15.5 Mtr level Floor at 19 Mtr level, Floor at 23 Mtr level, Floor at 29.8 Mtr level Floor at 34.9 Mtr level Lift Height/Travel 35 Mtrs or as per civil Building size- bidder should clearly specify in their tender compliance Minimum Lift Height As per manufacturers standard design Speed Minimum 1 Mtrs per second and above /as per manufacturers standard design.-Bidder should clearly specify in their tender compliance Machine Room Location At the Top of the lift shaft Power supply 415 + 10 %V, 3 Phase, 50 Hz, AC as specified in the specs Type of Drive Gearless with M/C Room as specified in the technical specifications. bidder should clearly specify in their tender compliance Input panel for lift comprising ELCB/RCCB, MCB, RYB indication lamps, volts, amps meters with input, output terminals and housing etc for Lift Make - OTIS/KONE/THYSSEN KRUPP/RASHI /JHONSON /COMFORT/TK Elevator other Details are as specified in the technical specifications | Each | 4491670.0 | 4491670.0 | 1.0 | False | None | None | False | None | False | 4491670.0 | 0 |
| 3566568 | 129356 | None | code495 | GOODS LIFT : SMP GODOWN Capacity-1500 Kgs. Levels - 2 Shaft Way Size 2900mm Width x 2900mm Depth Size of the carriage - 1.8/1.5 Mtrs x 2.0/2.3 Mtrs or as per manufacturers standard design etc.. complete as per specifications Type Goods /Freight Lift Capacity of Goods Lift 1500Kgs Shaft Way Size 2900mm Width x 2900mm Depth Size of the carriage Minimum 1.8/1.5 Mtrs x 2.0/2.3 Mtrs or as per manufacturers standard design /as per shaft size and capacity of lift - bidder should clearly specify in their tender compliance Door opening Minimum 1.4 Mtrs , center /side opening automatic or as per manufacturers standard design to suit site requirements/conditions /material handling equipment movements - bidder should clearly specify in their tender compliance Levels /stops 2 Levels /stops Ground floor at 0 mtr level First floor at 4.5 Mtr level Lift Height/Travel 4.5 Mtrs or as per civil Building size- bidder should clearly specify in their tender compliance Minimum Lift Height As per manufacturers standard design Speed Minimum 0.75-1 Mtrs per second - as per manufacturers standard design.- bidder should clearly specify in their tender compliance Machine Room Location At the Top of the lift shaft Power supply - 415 + 10 %V, 3 Phase, 50 Hz, AC as specified in the specs Type of Drive-Geared or gearless with M/C Room as specified in the technical specifications. bidder should clearly specify in their tender compliance Input panel for lift comprising ELCB/RCCB, MCB, RYB indication lamps, volts, amps meters with input, output terminals and housing etc for Lift Make Of Goods Lift- OTIS/KONE/THYSSEN KRUPP/RASHI /JHONSON /COMFORT/TK Elevator All other data as specified in the technical specifications | Each | 4369540.0 | 4369540.0 | 1.0 | False | None | None | False | None | False | 4369540.0 | 0 |
| 3566569 | 129356 | None | code496 | Fabricating, supplying and erection of 7 Mtrs long double arm cast iron ornamental poles as per Engineer incharge | Each | 142485.0 | 142485.0 | 10.0 | False | None | None | False | None | False | 1424850.0 | 0 |
| 3566570 | 129356 | None | code497 | Supply of LED decorative round shaped down light (IS) fittings with 120W System Power consumption. LED Efficiency greater than 130lm/w, nominal CRI greater than75.Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI & any Government certifiedagency & Design & Development facility certified by ISO9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Bodypart. Warranty of 2 Years against any manufacturing defectworking under standard electrical conditions as mentionedabove should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source. | Each | 33925.0 | 33925.0 | 20.0 | False | None | None | False | None | False | 678500.0 | 0 |
| 3566571 | 129356 | None | code498 | F MODULAR LAB EQUIPMENTS & RELATED WORKS A) Analytical Lab1) Interiors & Furnitures Model Island table with granite top Dimension 12L X5 W x 3H HSN 9403 | Nos | 783047.22 | 783047.22 | 5.0 | False | None | None | False | None | False | 3915236.1 | 0 |
| 3566572 | 129356 | None | code499 | a. Reagent rack with Power point and Toughened gass shelves (2 Tier) Dimension :1000’ L X 300’ W x 600’H [HSN 9403] | Nos | 43627.28 | 43627.28 | 12.0 | False | None | None | False | None | False | 523527.36 | 0 |
| 3566573 | 129356 | None | code500 | b. 2 way gas valve | Nos | 7271.21 | 7271.21 | 14.0 | False | None | None | False | None | False | 101796.94 | 0 |
| 3566574 | 129356 | None | code501 | a. P.P.sink with outlet nipple and waste out pipe Dimension :600'L X 450’ W x300’H [HSN 9403] | Nos | 16219.84 | 16219.84 | 17.0 | False | None | None | False | None | False | 275737.28 | 0 |
| 3566575 | 129356 | None | code502 | c.Peg Board with 24 pegs Dimension :600'L X 600’ W x25 T [HSN 9403] | Nos | 25169.68 | 25169.68 | 12.0 | False | None | None | False | None | False | 302036.16 | 0 |
| 3566576 | 129356 | None | code503 | d. 3 way water flow faucet brass with Epoxy powder coating | Nos | 11186.39 | 11186.39 | 17.0 | False | None | None | False | None | False | 190168.63 | 0 |
| 3566577 | 129356 | None | code504 | Wall side Table with Granite Top Dimension :12 L X 2.5W x 3 H HSN 9403 | Nos | 251694.35 | 251694.35 | 10.0 | False | None | None | False | None | False | 2516943.5 | 0 |
| 3566578 | 129356 | None | code505 | c. Race ways Power panel with 5/16 amps socket, switch and indicator (3Nos) Dimension :1800'L X 110’ W x110’H [HSN 9403] | Nos | 10068.11 | 10068.11 | 230.0 | False | None | None | False | None | False | 2315665.3 | 0 |
| 3566579 | 129356 | None | code506 | L Shape wall side table with granite top Dimension :(14+11 10") L X 2.5 W x3H [HSN 9403] | Nos | 559319.44 | 559319.44 | 6.0 | False | None | None | False | None | False | 3355916.64 | 0 |
| 3566580 | 129356 | None | code507 | d. 2 Way eye wash | Nos | 22372.78 | 22372.78 | 17.0 | False | None | None | False | None | False | 380337.26 | 0 |
| 3566581 | 129356 | None | code508 | Storage Rack SS304 G with 5 shelves Dimension : 3' L X1.5’ D X 6’ H | Nos | 111851.79 | 111851.79 | 10.0 | False | None | None | False | None | False | 1118517.9 | 0 |
| 3566582 | 129356 | None | code509 | 2 ) Insulation & HVAC Works : Supply & Installation of 50 mm thick double skin wall panel made of 0.5 mm thick one side PPGI sheet and one side PPGI on both sides with mounting accessories and puf of density 40 Kg/m as in fill ( Panel Including fixing Accessories like " L " Angle ,"& C " Channel, etc.) | Sqm | 8428.58 | 8428.58 | 550.45 | False | None | None | False | None | False | 4639511.861 | 0 |
| 3566583 | 129356 | None | code510 | Supply and Installation of Modular sandwiched Ceiling panel of 50mm thickness with both sides PPGI sheet with puf insulated as per manufacturer's standard and as per sample approval. | Sqm | 7464.62 | 7464.62 | 451.04 | False | None | None | False | None | False | 3366842.2048 | 0 |
| 3566584 | 129356 | None | code511 | View panel Tuffenned glass6mm thickness with frame (3’x2’) | Nos | 10906.82 | 10906.82 | 24.0 | False | None | None | False | None | False | 261763.68 | 0 |
| 3566585 | 129356 | None | code512 | Clean Room Doors are designed to fit flush into the wall panel system on both sides and are supplied in different dimensions. Doors are fabricated from galvanized iron sheets duly epoxy powder coated. Shutter has sheet thickness of 1mm and the frame of 1.2mm. jam depth of door shutter inline with adjacent panel thickness and shutter width of 44mm. Doors are available in various sizes as per the requirement. The following accessories are a part of the door: Stainless steel hinges ; Door shutter should with minimum leakage ; Stainless Steel 'D' type of handles on pull side ; Stainless steel push plates on push side with 0.8mm thick or ebow operated L handle ; Dorset/ryobi make heavy duty door closure ; Single glazed View panel along with triangular clips and silicon sealant (300mmWx750mmH) with toughened glass with 5mm thick. ; Mortice dead lock (ML100D) with one Side Key Operation Cylinder-Dorset : Single Leaf (7’X4’) | Nos | 38033.48 | 38033.48 | 2.0 | False | None | None | False | None | False | 76066.96 | 0 |
| 3566586 | 129356 | None | code513 | Single Leaf (7’X3’) | Nos | 35796.93 | 35796.93 | 20.0 | False | None | None | False | None | False | 715938.6 | 0 |
| 3566587 | 129356 | None | code514 | Supply and Installation of SS- 304 Apron Cabinet | Nos | 89491.11 | 89491.11 | 3.0 | False | None | None | False | None | False | 268473.33 | 0 |
| 3566588 | 129356 | None | code515 | Supply and installation of SS -304 Shoe Rack | Nos | 40271.24 | 40271.24 | 4.0 | False | None | None | False | None | False | 161084.96 | 0 |
| 3566589 | 129356 | None | code516 | Supply, installation, testing and commissioning of split type A/C units, each of nominal capacity as indicated below suitable for operation on 230 V + or 400 V +/-10%, 50 HZ, AC supply with R-22 refrigerant and shall be Star 3 rated as per B.E.E.
Each Split type A/C (Cassette Type) unit shall comprise of outdoor unit suitable for ambient weather conditions at the site and high wall mounted Indoor unit with sleek outer cabinet . Both units shall be interconnected through refrigerant(copper) tubing encased in PVC pipes for mechanical protection where refrigerant pipes are run on ground or on suitable sized cable tray and complete with electrical wiring for satisfactory operation and complete as required.
Outdoor (condensing) unit shall be finished with powder coating & should include hermetically sealed suction gas cooled compressors, overload protection, air cooled condenser coil of sufficient rows deep and of large face area, fitted with a propeller type fan and suitable motor, service valves arrangements, refrigerant filter etc., all housed in sheet metal cabinet.
Hi Wall Indoor unit should include evaporator coil of sufficient rows deep with slide out washable nylon wire mesh/HDPE filters with dirt trap and aluminium frame work, statically and dynamically balanced blower unit mounted on the shaft of the motor and housed in a scroll etc.,.Selector control unit with push button, selector switch for multispeed fan operation shall be provided for all units. Supply air grilles made out of non corrosive material with adjustable air flow direction arrangement with deflection louvers with throw of at least 6 mtrs and complete as required.Insulated drain pan with built in auto drain pump, decorative Panel. Necessary supports for mounting casseette unit shall be included. The Hi wall split units to have a cordless remote control.
The split units shall have following features:(i) Auto mode operation,(ii)Sleep mode operation,(iii)Auto setting with memory backup,(iv)Time delay feature
Each unit shall include suitable controls like thermostat and complete as required. These units shall be installed at appropriate locations as shown in the equipment layout drawing or as per site condition.
The drain pipes from indoor unit will be terminated at agreed drain point. The refrigerant piping shall be provided with no joints in between and suction lines shall be insulated with elastomeric nitrile foam pipe insulation. The quoted cost shall include: Cost of refrigerant piping with insulation and cabling along with refrigerant piping accessories like drier, sight glass and isolating valves, adequately supported on cable tray & MS support for mounting the Out Door Unit and necessary drain piping to the nearest drain.
Supply and Fixing of Stablizers - 4Nos
Supply and Installation of Refrigerant Piping with 19 mm thick Closed Cell Nitrile rubber insulation of following sizes- Inclussive of cabling & necessary Supports as per standard practices.
Gas Line & Liquid Line - 10 Rmt
Supply and Fixing of MS Powedr coated frame work for condenser unit - 4 Nos
Supply, Installation and Testing of PVC heavy class drain piping insulated out of 6mm thick Class O closed cell elastomeric nitrile rubber material of approved make as per specification complete with supports, consumables, fittings, pipe sleeves, U trap & leak arresting of following sizes. - 10 Rmt
Power wiring between indoor and outdoor units with PVC Conduit.
DX HWSU- 2.0 TR. ( MAIN LAB ) | Nos | 123050.28 | 123050.28 | 1.0 | False | None | None | False | None | False | 123050.28 | 0 |
| 3566590 | 129356 | None | code517 | Vertical chemical storage cupboard Dimension : 950' L X600’ D X 1800’ H | Nos | 100677.5 | 100677.5 | 15.0 | False | None | None | False | None | False | 1510162.5 | 0 |
| 3566591 | 129356 | None | code518 | Wall Mounted cupboard Dimension :900'L X 300’ W x600’H [HSN 9403] | Nos | 41948.66 | 41948.66 | 5.0 | False | None | None | False | None | False | 209743.3 | 0 |
| 3566592 | 129356 | None | code519 | 2) Insulation & HVAC Works : Supply, Installation, Testing and Commissioning of air conditioning, double skin air handling units of GSS powder coated sheet metal, cabinet type, modular construction. Unit frame work shall have internally coved aluminum extrusion finish . The panels shall be of double-skinned construction with outter skin being of pre coated GI Sheet & inner skin being of plain GI Sheet. They shall incorporate min 45 mm thick injected HFC - Filler PUF insulation material of 40 Kg/M3 density, sandwiched between the external and internal sheets. Insulation shall be spread equal across the panel to avoid any air pocket. The unit panels skin thickness should be not less than 0.6 mm for outer skin and 0.6 mm for inner skin. All panels shall be sealed (anti fungicide sealant material) against the framework. The Panel shall be mounted flush with the frame members to create smooth surface inside and outside. AHU shall be complete with Mixing Box with Fresh air low leakage aluminum volume control damper & Return air connection with low leakage aluminium volume control damper. Filter section with G4 type washable filters. DX cooling coil section (Min. 4 rows) comprising of copper tubes with aluminium fins and Copper header. Coil inlet & outlet connetions shall be with CU Adaptor connected to copper header. | Nos | 1230502.77 | 1230502.77 | 1.0 | False | None | None | False | None | False | 1230502.77 | 0 |
| 3566593 | 129356 | None | code520 | 18 Swg SS 304 drain tray with 19mm thick insulation. Ping pong type drain trap shall be provided. Fan Section complete with Backward curved Centrifugal DIDW fans or Plug Fan mounted on common base frame, belt driven by suitably rated Eff1 motor with a Industrial type VFD with necessary electrical and controls, slide rail & belt guard. Anti Vibration Spring type isolators for Blower shall be considered. Cable entry gland shall be provided on the AHU casing.
The Fan Section to be provided with Marine type light fixtures and Limit switch which shall be internally wired terminating in a switch on the AHU casing. Fire proof double canvas connections (Fungal Resistant and Lint free) to be used to connect the fan to the AHU Casing. SS Perforated Diffuser Plate at Blower Outlet shall be provided. The Electrical wiring connecting between the Blower drive motor & Fire Damper limit switch shall be considered.
Double Flanged Bleed-off Damper with module for supply & fixing H-13 filter along with SS perforated grille shall be provided. Filter section with F7 & H-13 class (Non washable) disposable type filters Empty Section with Low leakage Aluminium volume control outlet damper for Supply. Magnahelic gauge fixing provision across pre and fine Filters.
Complete Units shall be mounted on a continuous common base frame & with suitably rated anti vibration spring type isolators (provided along with the unit). All dampers shall be low leakage type with lock & graduation arrangement. AHU - 1 25.5TR, 15KW, 11730CFM, 150 mm wg, Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser provided with necessary controls. : 8.5 TR | Nos | 447455.55 | 447455.55 | 1.0 | False | None | None | False | None | False | 447455.55 | 0 |
| 3566594 | 129356 | None | code521 | Copper refrigerant piping with insulation and cabling. : Suction Line | m | 1789.97 | 1789.97 | 30.0 | False | None | None | False | None | False | 53699.1 | 0 |
| 3566595 | 129356 | None | code522 | Liquid Line | m | 1789.97 | 1789.97 | 30.0 | False | None | None | False | None | False | 53699.1 | 0 |
| 3566596 | 129356 | None | code523 | Expansion Valve | Nos | 9508.98 | 9508.98 | 1.0 | False | None | None | False | None | False | 9508.98 | 0 |
| 3566597 | 129356 | None | code524 | Drier | Nos | 7271.21 | 7271.21 | 1.0 | False | None | None | False | None | False | 7271.21 | 0 |
| 3566598 | 129356 | None | code525 | Supply and Installation of Electrical Control Panel For AHU Motor Interlocking with Out door Condensing Units | Nos | 95084.91 | 95084.91 | 1.0 | False | None | None | False | None | False | 95084.91 | 0 |
| 3566599 | 129356 | None | code526 | Supply and Laying of Electrcal Control Cabling from Our New Control Pnael to AHU Motor,Limit Switch, Condensing Units Up to Our Control Panel Cabling -By Cleant Scope | m | 1230.83 | 1230.83 | 65.0 | False | None | None | False | None | False | 80003.95 | 0 |
| 3566600 | 129356 | None | code527 | Unloading, Shifting, Lifting, Positioning of the AHU ODU& Condensing Units in the respective position at service floor as per Drawings. | Lot | 39152.97 | 39152.97 | 1.0 | False | None | None | False | None | False | 39152.97 | 0 |
| 3566601 | 129356 | None | code528 | Factory Fabricated, Non-Soldered Ducting using GSS sheet with supply & return outlets, All transverse connectors / TDF flanges shall be with 6mm thk neoprene gaskets and with C cleats. Duct supports shall be with support angle, GI supports rod and anchor bolts has to be included. The duct shall be Longitudinal sealed with silicon sealant from factory.
22 swg | Sqm | 1566.07 | 1566.07 | 50.0 | False | None | None | False | None | False | 78303.5 | 0 |
| 3566602 | 129356 | None | code529 | 24 swg | Sqm | 1454.73 | 1454.73 | 120.0 | False | None | None | False | None | False | 174567.6 | 0 |
| 3566603 | 129356 | None | code530 | Thermal Insulation of ducts with Self adhesive type, physically cross linked poly olefin foam insulation with factory applied reinforced aluminum foil facing on one side. The Joints shall be sealed using factory supplied reinforced aluminium foil tape 75mm wide. : 13 mm thick | Sqm | 1342.17 | 1342.17 | 150.0 | False | None | None | False | None | False | 201325.5 | 0 |
| 3566604 | 129356 | None | code531 | 8 mm thick | Sqm | 1118.28 | 1118.28 | 150.0 | False | None | None | False | None | False | 167742.0 | 0 |
| 3566605 | 129356 | None | code532 | Supply and Applying of Duct Sealing with Silicon Sealant of Supply and Return air ducts | m | 16780.19 | 16780.19 | 1.0 | False | None | None | False | None | False | 16780.19 | 0 |
| 3566606 | 129356 | None | code533 | Supply and Installation Flexible Canvas connections for Air Handling Units inlet & outlet | Nos | 3803.83 | 3803.83 | 2.0 | False | None | None | False | None | False | 7607.66 | 0 |
| 3566607 | 129356 | None | code534 | Air Terminal Devices : Supply & installation of Powder Coated Aluminium supply, double deflection grilles with GI damper section. | Sqm | 17898.46 | 17898.46 | 5.0 | False | None | None | False | None | False | 89492.3 | 0 |
| 3566608 | 129356 | None | code535 | Supply & installation of Powder Coated Aluminium Return, double deflection grilles with GI damper section. | Sqm | 17898.46 | 17898.46 | 5.0 | False | None | None | False | None | False | 89492.3 | 0 |
| 3566609 | 129356 | None | code536 | VOLUME CONTROL DAMPER : Supply, Installation, Testing and Commissioning of Low Leakge GI Duct Volume Control Dampers (for duct system) with coloured graduation & locking arrangement | Sqm | 12863.8 | 12863.8 | 1.0 | False | None | None | False | None | False | 12863.8 | 0 |
| 3566610 | 129356 | None | code537 | Supply, Installation, Testing and Commissioning of Fire Damper With Fusible Link | Nos | 13424.15 | 13424.15 | 1.0 | False | None | None | False | None | False | 13424.15 | 0 |
| 3566611 | 129356 | None | code538 | MS SUPPORT STRUCTURES : Supply, Fabrication & installation of MS supports structure with one coat of epoxy paint over & above two coats of anti-corresive red oxide paint. | Kgs | 223.9 | 223.9 | 500.0 | False | None | None | False | None | False | 111950.0 | 0 |
| 3566612 | 129356 | None | code539 | COVING : Supply and installation of NLT 2mm thick anodised aluminium Covings with all necessary accessories. | m | 951.26 | 951.26 | 887.0 | False | None | None | False | None | False | 843767.62 | 0 |
| 3566613 | 129356 | None | code540 | 3D or 2D internal corner coves between wall panels and ceiling panels | Nos | 804.82 | 804.82 | 106.0 | False | None | None | False | None | False | 85310.92 | 0 |
| 3566614 | 129356 | None | code541 | STATIC PASS BOX
Pass Box (Static): MOC SS 304 and finished with 220 grit matte with internally coved joints & with sandwiched door with double sided view panel, handle and properly placed, fitted and sealed on to the modular wall panel (along with SS pipe structure support from floor) with the following features:
* Electromagnetic door interlocking system
* 500 lux illumination level
* UV Lighting to eliminate germicidal growth with switch control & hour meter
* Action and alarm system ( if the door is open for more than 2 minutes)
SPB - 600 x 600 x 600mm ( Outer to Outer ) | Nos | 106271.3 | 106271.3 | 7.0 | False | None | None | False | None | False | 743899.1 | 0 |
| 3566615 | 129356 | None | code542 | Work station 3500 x 750 x 750 H - Under structure is manufactured from Mild steel and epoxy powder coated with thickness of 40-60 microns.Table Top .is Particle board with 20mm thick. Partition screen is of fabric materials. Single way race way with 6 mod cutouts | Nos | 52543.51 | 52543.51 | 4.0 | False | None | None | False | None | False | 210174.04 | 0 |
| 3566616 | 129356 | None | code543 | Metal keyboard tray | Nos | 2534.99 | 2534.99 | 14.0 | False | None | None | False | None | False | 35489.86 | 0 |
| 3566617 | 129356 | None | code544 | Pvc skirting-50mtr | m | 1152.27 | 1152.27 | 380.0 | False | None | None | False | None | False | 437862.6 | 0 |
| 3566618 | 129356 | None | code545 | Floor mounted fumehood of Size 4feet x 2.5feet x 2feet 4’(L) x 2.5’(W) x 8’(H)
Technical Specification:
Fume hood of Floor Mounted type with cup board.
The main body of the Fume Cupboard is made of GI with inner body with FRP lining, which is acid or alkali resistant,
Fluorescent light is provided inside the chamber for easy working. Have 0.5HP Inbuilt centrifugal blower
Have 2 nos of 5/32A power socket
Bottom Table with Cup Board
Dimension: 4’(L) x 2.5’(W) x 8’(H)
Consists of Nozzle for Nitrogen gas-01 nos,
The material made of of 1mm Thick Galvanized Iron , Surface Epoxy Powder coated (80-100micron) and Table Top with Jet Black Granite of 19mm +/- 1mm Thick. | Nos | 317258.34 | 317258.34 | 1.0 | False | None | None | False | None | False | 317258.34 | 0 |
| 3566619 | 129356 | None | code546 | Outer corner coving for the lab areas | m | 2165.96 | 2165.96 | 6.0 | False | None | None | False | None | False | 12995.76 | 0 |
| 3566620 | 129356 | None | code547 | Single leaf door 1000 mm (W) x 2100 mm (H) | Nos | 62698.85 | 62698.85 | 18.0 | False | None | None | False | None | False | 1128579.3 | 0 |
| 3566621 | 129356 | None | code548 | Double leaf door 1500 mm (W) x 2100 mm (H) | Nos | 94618.27 | 94618.27 | 4.0 | False | None | None | False | None | False | 378473.08 | 0 |
| 3566622 | 129356 | None | code549 | Double leaf door 2000 mm (W) x 2100 mm (H) | Nos | 125397.7 | 125397.7 | 4.0 | False | None | None | False | None | False | 501590.8 | 0 |
| 3566623 | 129356 | None | code550 | Supply and Installation of false ceiling Lights by doing Cutouts and fixing of necessary C caps in the ceiling panel :
Light sizes 2 feet x 2 feet (Square type) 36 WATTS for cleanroom | Nos | 13842.6 | 13842.6 | 83.0 | False | None | None | False | None | False | 1148935.8 | 0 |
| 3566624 | 129356 | None | code551 | Light sizes 1 feet x 1 feet (Round type) 18 WATTS for cleanroom areas | Nos | 10585.52 | 10585.52 | 10.0 | False | None | None | False | None | False | 105855.2 | 0 |
| 3566625 | 129356 | None | code552 | DYNAMIC PASS BOX : Supply,Installation,Testing,Commissioning & Validation of dynamic pass box made of 18 Gauge (1.2 mm) SS 304 sheets and smoothened to 240 grit with internally round SS covings ,with insulated sandwiched panels & doors ,with double glazed clear glass view panels and with SS 304 door handles.Passbox to be provided with permanently lubricated blower with aluminium frame.Passbox shall be provided with pre-filter(G-4 filter) and final filter (Minipleat H-14) sections to maintain ISO Class 5 environment. Fully flushed/Fully protected and glass cased CFL and UV lights to be provided within the pass box and interlocked with the doors. Separate switches for UV(also Hour meter) and CFL lights to be provided on both sides of the front panels. SS 304 perforated /linear grills for air suction shall be provided in the cleaner side.Passbox to be provided with emergency push buttons for door opening ,alarm for blower failure, alarm for alerting the personnel's of an open/unattended door,magnehelic gauges across H-14 filters section, DOP port etc.Pass boxes to be provided with timer controlled door opening.
DPB - 610 x 610 x 1200mm ( Outer to Outer ) | Nos | 223924.47 | 223924.47 | 2.0 | False | None | None | False | None | False | 447848.94 | 0 |
| 3566626 | 129356 | None | code553 | AIR CURTAIN : Supply and Installation of Air curtain for the Microbiology entrance door. Air curtain size will be 3.5feet single phase motor with dual blowers and the air flow will be upto 9feet height at 12 to 14m/s velocity | Nos | 118557.83 | 118557.83 | 1.0 | False | None | None | False | None | False | 118557.83 | 0 |
| 3566627 | 129356 | None | code554 | SS Cross over Bench in Change Room, Dimensions 11.5' L x 1.5' D x 2' H- 1nos | Set | 87830.63 | 87830.63 | 2.0 | False | None | None | False | None | False | 175661.26 | 0 |
| 3566628 | 129356 | None | code555 | SS Apron unit - 1nos in change room | Nos | 99863.4 | 99863.4 | 3.0 | False | None | None | False | None | False | 299590.2 | 0 |
| 3566629 | 129356 | None | code556 | Supply and Installation of GAS line for the labs
Tube 1/4"OD Seamless SS - 30mtr
Union 1/4"OD SS - 10nos
Tube 1/2"OD Seamless SS - 60mtr
Union 1/2"OD SS - 10nos
Reducing Tee 1 /2" x1/4"OD SS - 7nos
Equal Tee 1/4"OD SS - 3nos
Ball valve 1/2"OD SS - 3nos
Connector 1/4"OD SS - 7nos
LPG Valve 1/4" SS - 7nos
Adjustable Pressure Regulator Inlet Pressure: 5 TO 6 KG/CM2 Outlet Pressure: 2 KG/CM2 ; Flow: 20NM3/HR ; SIZE:: 1 ”BSP(F) - 1nos
Preset Pressure regulator With Gauge - 1nos
Flame arrestor with connector - 1nos
Ball valve 1/2''OD S/E SS - 3nos
1+1 Cylinder manifold With Isolation Valve - 1nos
Hose With Adaptor - 2nos
Stuaff calamps 1/2"OD PP - 50nos
Stuaff calamps 1/4"OD PP - 20nos
Rail channel -10 mtr
Thread rod M8 - 20mtr
Gatta Screw, Sleev, CCB Anchor Fastner - 1 lot | Lot | 371800.66 | 371800.66 | 1.0 | False | None | None | False | None | False | 371800.66 | 0 |
| 3566630 | 129356 | None | code557 | Supply, installation, testing and commissioning of split type A/C units, each of nominal capacity as indicated below suitable for operation on 230 V + or 400 V +/-10%, 50 HZ, AC supply with R-22 refrigerant and shall be Star 3 rated as per B.E.E. Each Split type A/C (Cassette Type) unit shall comprise of outdoor unit suitable for ambient weather conditions at the site and high wall mounted Indoor unit with sleek outer cabinet . Both units shall be interconnected through refrigerant(copper) tubing encased in PVC pipes for mechanical protection where refrigerant pipes are run on ground or on suitable sized cable tray and complete with electrical wiring for satisfactory operation and complete as required. Outdoor (condensing) unit shall be finished with powder coating & should include hermetically sealed suction gas cooled compressors, overload protection, air cooled condenser coil of sufficient rows deep and of large face area, fitted with a propeller type fan and suitable motor, service valves arrangements, refrigerant filter etc., all housed in sheet metal cabinet. Hi Wall Indoor unit should include evaporator coil of sufficient rows deep with slide out washable nylon wire mesh/HDPE filters with dirt trap and aluminium frame work, statically and dynamically balanced blower unit mounted on the shaft of the motor and housed in a scroll etc.,.Selector control unit with push button, selector switch for multispeed fan operation shall be provided for all units. Supply air grilles made out of non corrosive material with adjustable air flow direction arrangement with deflection louvers with throw of at least 6 mtrs and complete as required.Insulated drain pan with built in auto drain pump, decorative Panel. Necessary supports for mounting casseette unit shall be included. The Hi wall split units to have a cordless remote control. The split units shall have following features:(i) Auto mode operation,(ii)Sleep mode operation,(iii)Auto setting with memory backup,(iv)Time delay feature Each unit shall include suitable controls like thermostat and complete as required. These units shall be installed at appropriate locations as shown in the equipment layout drawing or as per site condition. The drain pipes from indoor unit will be terminated at agreed drain point. The refrigerant piping shall be provided with no joints in between and suction lines shall be insulated with elastomeric nitrile foam pipe insulation. The quoted cost shall include: Cost of refrigerant piping with insulation and cabling along with refrigerant piping accessories like drier, sight glass and isolating valves, adequately supported on cable tray & MS support for mounting the Out Door Unit and necessary drain piping to the nearest drain.
Supply and Fixing of Stablizers - 4Nos
Supply and Installation of Refrigerant Piping with 19 mm thick Closed Cell Nitrile rubber insulation of following sizes- Inclussive of cabling & necessary Supports as per standard practices.
Gas Line & Liquid Line - 10 Rmt
Supply and Fixing of MS Powedr coated frame work for condenser unit - 4 Nos
Supply, Installation and Testing of PVC heavy class drain piping insulated out of 6mm thick Class O closed cell elastomeric nitrile rubber material of approved make as per specification complete with supports, consumables, fittings, pipe sleeves, U trap & leak arresting of following sizes. - 10 Rmt
Power wiring between indoor and outdoor units with PVC Conduit.
DX HWSU- 1.5TR. | Nos | 200656.3 | 200656.3 | 10.0 | False | None | None | False | None | False | 2006563.0 | 0 |
| 3566631 | 129356 | None | code558 | SS Lab Chairs with Back Rest - Understructure Manufactured from standard 18G & 20G of GI Sheets and epoxy powder coated with thickness of 40-60 microns. Top is made up of SS 304. | Nos | 21432.22 | 21432.22 | 22.0 | False | None | None | False | None | False | 471508.84 | 0 |
| 3566632 | 129356 | None | code559 | Executive Table with Side Table - 1500mm x 750mm x 750mm (LxWxH) | Nos | 67172.73 | 67172.73 | 1.0 | False | None | None | False | None | False | 67172.73 | 0 |
| 3566633 | 129356 | None | code560 | Executive High Back Chair - Revolving type with castors. Head rest, arm rest with adjustable height. | Nos | 24417.37 | 24417.37 | 1.0 | False | None | None | False | None | False | 24417.37 | 0 |
| 3566634 | 129356 | None | code561 | Visitors Chairs - Seat and back cusion with fixed arm rest and height. | Nos | 13589.1 | 13589.1 | 3.0 | False | None | None | False | None | False | 40767.3 | 0 |
| 3566635 | 129356 | None | code562 | Normal Chairs for work stations | Nos | 22973.19 | 22973.19 | 4.0 | False | None | None | False | None | False | 91892.76 | 0 |
| 3566636 | 129356 | None | code563 | SS Glassware storage rack | Nos | 142666.39 | 142666.39 | 2.0 | False | None | None | False | None | False | 285332.78 | 0 |
| 3566637 | 129356 | None | code564 | ELECTRICAL WORKS : CONTROL CABLING & END TERMINATION
100*50mm PVC Raceway | m | 2534.99 | 2534.99 | 100.0 | False | None | None | False | None | False | 253499.0 | 0 |
| 3566638 | 129356 | None | code565 | POINT WIRING for PVC Conduit - Clean room area
Supply, Installation, Testing & Commissioning of light points using necessary materials like 25mm dia PVC Conduit for exposed conduit, 3R x 1.5 sqmm FRLS category & insulated MSCC wires, 6A switch with plate, 16G GI box and other point wiring accessories & carrying out surface wiring. The rate shall include earthing of all points. The quoted rates shall also include PVC flexible & all accessories, tools, labour etc. No separate payment will be made for wall chasing, cleaning of debris, rough plastering the chased wall / floor. The rate shall include looping between points. The wiring size is limited to lighting circuits (Max.1100W) point wiring limited to 100W per socket outlet. All accessories shall be IS approved.
Chipping in wall for installation of conduits, putting JBs/DBs in wall, taking cable in wall, chipping to be carried out within precast bricks / blocks etc. after installation, doing proper plastering with cement and complete the job in accordance with directions of Engineer - in -charge.
1 light point controlled by a 6A switch | Nos | 2189.31 | 2189.31 | 45.0 | False | None | None | False | None | False | 98518.95 | 0 |
| 3566639 | 129356 | None | code566 | 2 light point controlled by a 6A switch | Nos | 2842.27 | 2842.27 | 20.0 | False | None | None | False | None | False | 56845.4 | 0 |
| 3566640 | 129356 | None | code567 | Normal raw power Lighting Circuit & Emergency Lighting Circuit
Circuit main for lighting circuit consisting of 2ran x 2.5 sqmm & 1run 1.5sqmm flexible copper FRLS cable in 25 mm dia PVC Conduit with all accessories for Lightiing circuit [From DBs to First switch box & looping between Switch to Switch] | m | 238.14 | 238.14 | 500.0 | False | None | None | False | None | False | 119070.0 | 0 |
| 3566641 | 129356 | None | code568 | Power Circuit [For 1 Phase Sockets]: Circuit main for power circuit consisting of 4 sqmm 2R& 2.5sqmm 1R flexible copper FRLS cable laid in Existing 25 mm dia PVC conduit / Raceway with all accessories for Raw Power Circuits & UPS circuit. | m | 353.36 | 353.36 | 700.0 | False | None | None | False | None | False | 247352.0 | 0 |
| 3566642 | 129356 | None | code569 | Power Circuit [For 1 Phase Sockets]: CLEAN ROOM AREA : Supply & fixing of 2x 16A, socket controlled with 2 x 16A Switch with plate as one set 240V, 1 Ph commercial switched with including interconnection etc., complete. The sockets shall be with face plate, GI BOX and accessories. | Nos | 2381.36 | 2381.36 | 60.0 | False | None | None | False | None | False | 142881.6 | 0 |
| 3566643 | 129356 | None | code570 | Supply & fixing of16A, socket controlled with 16A Switch with plate as one set 240V, 1 Ph commercial switched with including interconnection etc., complete. The sockets shall be with face plate, GI BOX and accessories. | Nos | 1613.18 | 1613.18 | 30.0 | False | None | None | False | None | False | 48395.4 | 0 |
| 3566644 | 129356 | None | code571 | Supplying, installing and testing approved make 25 mm dia. PVC conduits on wall / ceiling complete with accessories like, Collars, Bends etc. | m | 122.91 | 122.91 | 400.0 | False | None | None | False | None | False | 49164.0 | 0 |
| 3566645 | 129356 | None | code572 | Supplying, installing and testing approved make 25 mm dia. PVC fluxible conduits on wall / ceiling complete etc. | m | 46.09 | 46.09 | 200.0 | False | None | None | False | None | False | 9218.0 | 0 |
| 3566646 | 129356 | None | code573 | Supply, Installation, Testing and commissioning of IP-43 TPN Vertical/ Horizontal MCB Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB as per specifications and required capacity MCB's shall conform to IS: 8828 DBs testing should be done as per IE Rules like leakage Test,Insulation Test Etc & With Sutible Powder Coated Vertical & Horizontal GI Raceways for DB Cables & wires Upto Cable tray with sutable supports Complete as Required.
a) 8Way TPN( Flexi type)with 63A 10KA 4 pole MCB as 3 nos 63A 2 pole RCCB and 8 nos 32A 10KA C Curve as outgoings for UPS DBs | Nos | 38716.27 | 38716.27 | 6.0 | False | None | None | False | None | False | 232297.62 | 0 |
| 3566647 | 129356 | None | code574 | a) 8Way SPN( Flexi type)with 40A 10KA 2 pole MCB as and 5 nos 32A 10KA C Curve as outgoings for UPS DBs | Nos | 19358.14 | 19358.14 | 6.0 | False | None | None | False | None | False | 116148.84 | 0 |
| 3566648 | 129356 | None | code575 | Supply & fixing of 32A , 5 pin Industrial Plug & Socket with 32A, 4P MCB, interconnection etc., | Nos | 8181.12 | 8181.12 | 6.0 | False | None | None | False | None | False | 49086.72 | 0 |
| 3566649 | 129356 | None | code576 | Power cable consisting of 5C x 6 sqmm flexible copper FRLS cable laid in Existing 25 mm dia conduit / Raceway with all accessories for Raw Power DB, Ind plug & Socket. | m | 737.45 | 737.45 | 250.0 | False | None | None | False | None | False | 184362.5 | 0 |
| 3566650 | 129356 | None | code577 | G SEWAGE TREATEMENT PLANT (STP - 30KLD)
Supply of 30KLD SBR TYPE Sewage Treatment Plant. Equipment as specified under “Technical Specifications mechanical, instrument and electrical” complete as per details. | Job | 2746407.05 | 2746407.05 | 1.0 | False | None | None | False | None | False | 2746407.05 | 0 |
| 3566651 | 129356 | None | code578 | Erection & Commissioning for 30KLD SBR TYPE Sewage Treatment Plant | Job | 162250.0 | 162250.0 | 1.0 | False | None | None | False | None | False | 162250.0 | 0 |