| 3564906 | 129284 | None | code01 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 3005.81 | 3005.81 | 33.61 | False | None | None | False | None | False | 101025.2741 | 0 |
| 3564907 | 129284 | None | code02 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 324.61 | 324.61 | 16.12 | False | None | None | False | None | False | 5232.7132 | 0 |
| 3564908 | 129284 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.38 | 126.38 | 22.25 | False | None | None | False | None | False | 2811.955 | 0 |
| 3564909 | 129284 | None | code04 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 371.08 | False | None | None | False | None | False | 217927.8624 | 0 |
| 3564910 | 129284 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 7702.86 | 7702.86 | 43.08 | False | None | None | False | None | False | 331839.2088 | 0 |
| 3564911 | 129284 | None | code06 | PCC below UCRS masonry | Cum | 7702.86 | 7702.86 | 4.86 | False | None | None | False | None | False | 37435.8996 | 0 |
| 3564912 | 129284 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) | Cum | 7834.19 | 7834.19 | 38.81 | False | None | None | False | None | False | 304044.9139 | 0 |
| 3564913 | 129284 | None | code08 | Appendix I Additionalities for Formwork, Centering & Scaffolding | Cum | 3917.1 | 3917.1 | 38.81 | False | None | None | False | None | False | 152022.651 | 0 |
| 3564914 | 129284 | None | code09 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with. Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6952.02 | 6952.02 | 9.12 | False | None | None | False | None | False | 63402.4224 | 0 |
| 3564915 | 129284 | None | code10 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7915.97 | 7915.97 | 8.27 | False | None | None | False | None | False | 65465.0719 | 0 |
| 3564916 | 129284 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 10173.42 | 10173.42 | 66.66 | False | None | None | False | None | False | 678160.1772 | 0 |
| 3564917 | 129284 | None | code12 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ceiling plaster | Sqm | 400.19 | 400.19 | 358.63 | False | None | None | False | None | False | 143520.1397 | 0 |
| 3564918 | 129284 | None | code13 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. inside wall plaster | Sqm | 477.01 | 477.01 | 459.29 | False | None | None | False | None | False | 219085.9229 | 0 |
| 3564919 | 129284 | None | code14 | Providing 18 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.outside wall plaster | Sqm | 477.01 | 477.01 | 578.97 | False | None | None | False | None | False | 276174.4797 | 0 |
| 3564920 | 129284 | None | code15 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 123.9 | 123.9 | 799.83 | False | None | None | False | None | False | 99098.937 | 0 |
| 3564921 | 129284 | None | code16 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 153886.27 | 153886.27 | 0.26 | False | None | None | False | None | False | 40010.4302 | 0 |
| 3564922 | 129284 | None | code17 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 8545.38 | 8545.38 | 10.5 | False | None | None | False | None | False | 89726.49 | 0 |
| 3564923 | 129284 | None | code18 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. as per directions of Engineer-in-charge | Nos | 1258.82 | 1258.82 | 5.0 | False | None | None | False | None | False | 6294.1 | 0 |
| 3564924 | 129284 | None | code19 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) 12.93.2 Size 62 X 125mm | Rmtr | 946.59 | 946.59 | 11.4 | False | None | None | False | None | False | 10791.126 | 0 |
| 3564925 | 129284 | None | code20 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. as per directions of Engineer-in-charge | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 |
| 3564926 | 129284 | None | code21 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVCMatching to RAL-9016 sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)as per directions of Engineer-in-charge | Sqm | 8343.42 | 8343.42 | 6.26 | False | None | None | False | None | False | 52229.8092 | 0 |
| 3564927 | 129284 | None | code22 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) as per directions of Engineer-in-charge | Sqm | 7085.84 | 7085.84 | 2.36 | False | None | None | False | None | False | 16722.5824 | 0 |
| 3564928 | 129284 | None | code23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 208.15 | 208.15 | 1781.23 | False | None | None | False | None | False | 370763.0245 | 0 |
| 3564929 | 129284 | None | code24 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 2931.47 | 2931.47 | 108.63 | False | None | None | False | None | False | 318445.5861 | 0 |
| 3564930 | 129284 | None | code25 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 10253.96 | 10253.96 | 16.96 | False | None | None | False | None | False | 173907.1616 | 0 |
| 3564931 | 129284 | None | code26 | Providing and laying Polished Glazed Vitrified tiles with thickness 10mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).as per directions of Engineer-in-charge | Sqm | 1642.91 | 1642.91 | 313.39 | False | None | None | False | None | False | 514871.5649 | 0 |
| 3564932 | 129284 | None | code27 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 3055.37 | 3055.37 | 74.7 | False | None | None | False | None | False | 228236.139 | 0 |
| 3564933 | 129284 | None | code28 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 2027.0 | 2027.0 | 18.02 | False | None | None | False | None | False | 36526.54 | 0 |
| 3564934 | 129284 | None | code29 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.as per directions of Engineer-in-charge | Sqm | 1370.34 | 1370.34 | 10.27 | False | None | None | False | None | False | 14073.3918 | 0 |
| 3564935 | 129284 | None | code30 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.as per directions of Engineer-in-charge | Sqm | 1795.31 | 1795.31 | 40.11 | False | None | None | False | None | False | 72009.8841 | 0 |
| 3564936 | 129284 | None | code31 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 61.95 | 61.95 | 112.55 | False | None | None | False | None | False | 6972.4725 | 0 |
| 3564937 | 129284 | None | code32 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 172.22 | 172.22 | 114.92 | False | None | None | False | None | False | 19791.5224 | 0 |
| 3564938 | 129284 | None | code33 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 170.98 | 170.98 | 10.5 | False | None | None | False | None | False | 1795.29 | 0 |
| 3564939 | 129284 | None | code34 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 818.9 | False | None | None | False | None | False | 158276.992 | 0 |
| 3564940 | 129284 | None | code35 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specification. One coats on old work including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m2 33.00 | Sqm | 52.03 | 52.03 | 221.12 | False | None | None | False | None | False | 11504.8736 | 0 |
| 3564941 | 129284 | None | code36 | Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 107.8 | 107.8 | 186.42 | False | None | None | False | None | False | 20096.076 | 0 |
| 3564942 | 129284 | None | code37 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.as per directions of Engineer-in-charge | Sqm | 1012.26 | 1012.26 | 560.88 | False | None | None | False | None | False | 567756.3888 | 0 |
| 3564943 | 129284 | None | code38 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Tonne | 110837.22 | 110837.22 | 3.047 | False | None | None | False | None | False | 337721.00934 | 0 |
| 3564944 | 129284 | None | code39 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New errace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 1012.26 | 1012.26 | 399.84 | False | None | None | False | None | False | 404742.0384 | 0 |
| 3564945 | 129284 | None | code40 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications Double groove | Kgs | 707.47 | 707.47 | 64.56 | False | None | None | False | None | False | 45674.2632 | 0 |
| 3564946 | 129284 | None | code41 | Providing and fixing 12 mm thick prelaminated particle board fla pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in charge: Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications | Sqm | 1111.38 | 1111.38 | 6.86 | False | None | None | False | None | False | 7624.0668 | 0 |
| 3564947 | 129284 | None | code42 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panels of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications | Sqm | 1450.86 | 1450.86 | 7.81 | False | None | None | False | None | False | 11331.2166 | 0 |
| 3564948 | 129284 | None | code43 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. Internal work, Conceled work, including cutting chases & making good the wall etc 15mm dia pipe in GF WC | Mtr | 382.85 | 382.85 | 30.0 | False | None | None | False | None | False | 11485.5 | 0 |
| 3564949 | 129284 | None | code44 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 25 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL. 25 mm dia pipe from borewell to terrace tank | Mtr | 40.0 | 40.0 | 40.0 | False | None | None | False | None | False | 1600.0 | 0 |
| 3564950 | 129284 | None | code45 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 32 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL 32mm dia pipe from terrace tank TO GF | Mtr | 495.6 | 495.6 | 10.0 | False | None | None | False | None | False | 4956.0 | 0 |
| 3564951 | 129284 | None | code46 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 g | Nos | 195.76 | 195.76 | 5.0 | False | None | None | False | None | False | 978.8 | 0 |
| 3564952 | 129284 | None | code47 | Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gms | Nos | 249.03 | 249.03 | 5.0 | False | None | None | False | None | False | 1245.15 | 0 |
| 3564953 | 129284 | None | code48 | Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) | Nos | 680.21 | 680.21 | 5.0 | False | None | None | False | None | False | 3401.05 | 0 |
| 3564954 | 129284 | None | code49 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. | Unit | 2844.74 | 2844.74 | 3.0 | False | None | None | False | None | False | 8534.22 | 0 |
| 3564955 | 129284 | None | code50 | 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms | Nos | 389.04 | 389.04 | 3.0 | False | None | None | False | None | False | 1167.12 | 0 |
| 3564956 | 129284 | None | code51 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length | Unit | 112.74 | 112.74 | 5.0 | False | None | None | False | None | False | 563.7 | 0 |
| 3564957 | 129284 | None | code52 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. | Each | 337.0 | 337.0 | 2.0 | False | None | None | False | None | False | 674.0 | 0 |
| 3564958 | 129284 | None | code53 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Unit | 1511.58 | 1511.58 | 3.0 | False | None | None | False | None | False | 4534.74 | 0 |
| 3564959 | 129284 | None | code54 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required | Pan | 7405.5 | 7405.5 | 2.0 | False | None | None | False | None | False | 14811.0 | 0 |
| 3564960 | 129284 | None | code55 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia | Each | 113.98 | 113.98 | 3.0 | False | None | None | False | None | False | 341.94 | 0 |
| 3564961 | 129284 | None | code56 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 477.01 | 477.01 | 56.88 | False | None | None | False | None | False | 27132.3288 | 0 |
| 3564962 | 129284 | None | code57 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.2 | False | None | None | False | None | False | 7128.698 | 0 |
| 3564963 | 129284 | None | code58 | KSRB 13-11.1 : Providing and placing on terrace,(at all floor levels) polyethylene water storage tank is:12701 marked with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.- | Ltr | 11.15 | 11.15 | 2000.0 | False | None | None | False | None | False | 22300.0 | 0 |
| 3564964 | 129284 | None | code59 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. | Mtr | 356.83 | 356.83 | 30.0 | False | None | None | False | None | False | 10704.9 | 0 |
| 3564965 | 129284 | None | code60 | STAINLESS STEEL GRAB BAR STEEL HANDE SIZE (48" inchs) Market Rate Rs.400 | Rft | 472.0 | 472.0 | 3.0 | False | None | None | False | None | False | 1416.0 | 0 |
| 3564966 | 129284 | None | code61 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet* Sand Cast Iron S&S as per IS: 1729 | Each | 1418.65 | 1418.65 | 3.0 | False | None | None | False | None | False | 4255.95 | 0 |
| 3564967 | 129284 | None | code62 | Supplying heavy gauge PVC conduit pipe ...2. mm dia.....25...mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Rmtr | 92.03 | 92.03 | 500.0 | False | None | None | False | None | False | 46015.0 | 0 |
| 3564968 | 129284 | None | code63 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. | Rmtr | 34.22 | 34.22 | 400.0 | False | None | None | False | None | False | 13688.0 | 0 |
| 3564969 | 129284 | None | code64 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP short point up to 3 mtr from tapping point out let via switch | Each | 336.3 | 336.3 | 12.0 | False | None | None | False | None | False | 4035.6 | 0 |
| 3564970 | 129284 | None | code65 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Each | 464.92 | 464.92 | 30.0 | False | None | None | False | None | False | 13947.6 | 0 |
| 3564971 | 129284 | None | code66 | long above 6 mtr up to 10 mtr from tapping point to out let via switch | Each | 672.6 | 672.6 | 40.0 | False | None | None | False | None | False | 26904.0 | 0 |
| 3564972 | 129284 | None | code67 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 | Each | 173.46 | 173.46 | 35.0 | False | None | None | False | None | False | 6071.1 | 0 |
| 3564973 | 129284 | None | code68 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way | Each | 376.42 | 376.42 | 26.0 | False | None | None | False | None | False | 9786.92 | 0 |
| 3564974 | 129284 | None | code69 | 4-5 way | Each | 208.86 | 208.86 | 10.0 | False | None | None | False | None | False | 2088.6 | 0 |
| 3564975 | 129284 | None | code70 | 8 way | Each | 258.42 | 258.42 | 8.0 | False | None | None | False | None | False | 2067.36 | 0 |
| 3564976 | 129284 | None | code71 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 modular | Each | 206.5 | 206.5 | 10.0 | False | None | None | False | None | False | 2065.0 | 0 |
| 3564977 | 129284 | None | code72 | 8 module | Each | 335.12 | 335.12 | 8.0 | False | None | None | False | None | False | 2680.96 | 0 |
| 3564978 | 129284 | None | code73 | 12 module | Each | 405.92 | 405.92 | 26.0 | False | None | None | False | None | False | 10553.92 | 0 |
| 3564979 | 129284 | None | code74 | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. 4 Way TP & N | Each | 3602.54 | 3602.54 | 1.0 | False | None | None | False | None | False | 3602.54 | 0 |
| 3564980 | 129284 | None | code75 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SP | Each | 489.7 | 489.7 | 35.0 | False | None | None | False | None | False | 17139.5 | 0 |
| 3564981 | 129284 | None | code76 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mm | Rmtr | 49.56 | 49.56 | 1200.0 | False | None | None | False | None | False | 59472.0 | 0 |
| 3564982 | 129284 | None | code77 | 4. 0 sq mm | Rmtr | 74.34 | 74.34 | 800.0 | False | None | None | False | None | False | 59472.0 | 0 |
| 3564983 | 129284 | None | code78 | 6.0 sq mm | Rmtr | 108.56 | 108.56 | 180.0 | False | None | None | False | None | False | 19540.8 | 0 |
| 3564984 | 129284 | None | code79 | Fixingall types and all capacities of 1'x4'/2'x2'LED Light fitting s indoor on the wall/ ceiling/ rafters/ girders with necessary supporting frame, using 2310.0076"twin twisted PVC insulated wires, required Nos of round blocks and clamps | Each | 578.2 | 578.2 | 2.0 | False | None | None | False | None | False | 1156.4 | 0 |
| 3564985 | 129284 | None | code80 | Supply of LED Street light luminaire with pressure diecast aluminium housing body for optimal thermal dissipation. Lamp compart ment comprising of anti glare clear diffuser with Injection moulded polycar bonate material, delivering superior light output Ratedli fe Burning Hrs 50000hr @Lumen Maintenance of 70 maximum lightin tensity should bebet ween 60 degrees to 70 degrees. CCT 55 00K, IP66 optical andel ectrical compart ment & impact resista nceofcomple teluminaire IK08.PowerF act or0.9withmains,Surge Protection-Min 5KV along with Over voltage Overload,shortcircuit/miss-wiring protection .Compat ible for polemounting withoute rdia of 40 mm to 50 mm. Universal Voltage driver toope ratewide volt agerange from100V to270V50/60 Hzapplication.Compliance to IS 10322 / IEC60598 , LM79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensuree a se of maintenance atthesi ghtsit elocation with minimized minimal tools. LED Light fixture with........W System Power consumption. LED Efficiency 1301 m/w,nominal CRI 75. Luminaire manufacture r shouldh avein-house facility accredit edbyNABL /CPRI & any Government certified agenc y & Design & Development facility certified by ISO9001:2008.Housing with supplier wordmark /names hallbe Engraved/ Embossing onthediecas thousing/ Bodypart.Warranty of 2Years against any manufacturing defect working under standard electrical condition sasmentioned above should begiven by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source | Each | 4748.32 | 4748.32 | 2.0 | False | None | None | False | None | False | 9496.64 | 0 |
| 3564986 | 129284 | None | code81 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body withlocking type hold ercompletely wired.Excluding Ballast & FluorescentTube 1 x 4' Tube light fitting. | Each | 317.42 | 317.42 | 60.0 | False | None | None | False | None | False | 19045.2 | 0 |
| 3564987 | 129284 | None | code82 | Fixing all types and all capacities of fluorescent/ falseceiling/ spotlight/CFL /LED fittings indoor on the wall/ ceiling/ rafters/ girders using 23/0. 0076 "twin twisted PVC insulated wires, required Nos of round blocks and clamps | Each | 143.96 | 143.96 | 60.0 | False | None | None | False | None | False | 8637.6 | 0 |
| 3564988 | 129284 | None | code83 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessoris (Smenclosure sheet metal Excution ) 125 A | Each | 6466.4 | 6466.4 | 1.0 | False | None | None | False | None | False | 6466.4 | 0 |
| 3564989 | 129284 | None | code84 | Supplying ..200........ amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 Amps 4x30 x 6 | Rmtr | 2908.7 | 2908.7 | 3.0 | False | None | None | False | None | False | 8726.1 | 0 |
| 3564990 | 129284 | None | code85 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. | Cum | 306.8 | 306.8 | 5.4 | False | None | None | False | None | False | 1656.72 | 0 |
| 3564991 | 129284 | None | code86 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LT UG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm | Km | 181793.16 | 181793.16 | 0.05 | False | None | None | False | None | False | 9089.658 | 0 |
| 3564992 | 129284 | None | code87 | Fabricating supplying and mounting MS box made out....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 18 SWG | Sq CM | 0.44 | 0.44 | 74090.0 | False | None | None | False | None | False | 32599.6 | 0 |
| 3564993 | 129284 | None | code88 | Supplying & Fixing Chemical earthling for grounding. Conduits,ICcut-outs & other equipments backfill compound whichisnon-corrosive,thermally conductive, potential to permissible limits, superior Faultconduction capacity,nontoxic,weather resistance&capable of achieving ohmic value less than one ohm | Each | 5343.04 | 5343.04 | 4.0 | False | None | None | False | None | False | 21372.16 | 0 |
| 3564994 | 129284 | None | code89 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 amps 25 ka four pole | Each | 7181.48 | 7181.48 | 1.0 | False | None | None | False | None | False | 7181.48 | 0 |
| 3564995 | 129284 | None | code90 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12' sweep (300mm) | Each | 3503.42 | 3503.42 | 3.0 | False | None | None | False | None | False | 10510.26 | 0 |
| 3564996 | 129284 | None | code91 | Fixing one exhaust fan inthenitchal ready leftint hewall with bolts and nuts and 5A. Ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 2.0 | False | None | None | False | None | False | 1161.12 | 0 |
| 3564997 | 129284 | None | code92 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16 amps one way switch | Each | 212.4 | 212.4 | 4.0 | False | None | None | False | None | False | 849.6 | 0 |
| 3564998 | 129284 | None | code93 | 6/16A univarsal socket | Each | 239.54 | 239.54 | 4.0 | False | None | None | False | None | False | 958.16 | 0 |
| 3564999 | 129284 | None | code94 | 400 watts dimmer | Each | 325.68 | 325.68 | 28.0 | False | None | None | False | None | False | 9119.04 | 0 |
| 3565000 | 129284 | None | code95 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48 sweep (1200 mm) regular model | Each | 3521.12 | 3521.12 | 28.0 | False | None | None | False | None | False | 98591.36 | 0 |
| 3565001 | 129284 | None | code96 | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. 4 Way TP & N | Each | 3602.54 | 3602.54 | 2.0 | False | None | None | False | None | False | 7205.08 | 0 |
| 3565002 | 129284 | None | code97 | Supplying of .1.5. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 1.5 Ton capacity 5 star | Each | 56265.94 | 56265.94 | 4.0 | False | None | None | False | None | False | 225063.76 | 0 |
| 3565003 | 129284 | None | code98 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette typeA/C. | Each | 3746.5 | 3746.5 | 4.0 | False | None | None | False | None | False | 14986.0 | 0 |
| 3565004 | 129284 | None | code99 | Chemical rust remover all complete as per the direction of Engineer-In-Charge. (For Roof Slab) | Sqm | 303.55 | 303.55 | 16.87 | False | None | None | False | None | False | 5120.8885 | 0 |
| 3565005 | 129284 | None | code100 | Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification. | Sqm | 469.58 | 469.58 | 16.87 | False | None | None | False | None | False | 7921.8146 | 0 |
| 3565006 | 129284 | None | code101 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 3005.81 | 3005.81 | 2.99 | False | None | None | False | None | False | 8987.3719 | 0 |
| 3565007 | 129284 | None | code102 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge For thickness of tiles above 10 mm and up to 25 mm | Sqm | 59.47 | 59.47 | 49.71 | False | None | None | False | None | False | 2956.2537 | 0 |
| 3565008 | 129284 | None | code103 | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. | Sqm | 16.1 | 16.1 | 135.27 | False | None | None | False | None | False | 2177.847 | 0 |
| 3565009 | 129284 | None | code104 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 3.3 | False | None | None | False | None | False | 417.021 | 0 |
| 3565010 | 129284 | None | code105 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 3.3 | False | None | None | False | None | False | 1938.024 | 0 |
| 3565011 | 129284 | None | code106 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 7702.86 | 7702.86 | 5.1 | False | None | None | False | None | False | 39284.586 | 0 |
| 3565012 | 129284 | None | code107 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 10173.42 | 10173.42 | 2.99 | False | None | None | False | None | False | 30418.5258 | 0 |
| 3565013 | 129284 | None | code108 | Providing 18 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.outside wall plaster | Sqm | 477.01 | 477.01 | 34.6 | False | None | None | False | None | False | 16504.546 | 0 |
| 3565014 | 129284 | None | code109 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 123.9 | 123.9 | 16.87 | False | None | None | False | None | False | 2090.193 | 0 |
| 3565015 | 129284 | None | code110 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1370.33 | 1370.33 | 23.94 | False | None | None | False | None | False | 32805.7002 | 0 |
| 3565016 | 129284 | None | code111 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1795.31 | 1795.31 | 113.01 | False | None | None | False | None | False | 202887.9831 | 0 |
| 3565017 | 129284 | None | code112 | Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specification. One coats on old work including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m2 33.00 | Sqm | 52.03 | 52.03 | 43.97 | False | None | None | False | None | False | 2287.7591 | 0 |
| 3565018 | 129284 | None | code113 | Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 107.79 | 107.79 | 52.47 | False | None | None | False | None | False | 5655.7413 | 0 |
| 3565019 | 129284 | None | code114 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace / Chajjas / Sunken portion of WC: Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 1012.26 | 1012.26 | 34.6 | False | None | None | False | None | False | 35024.196 | 0 |
| 3565020 | 129284 | None | code115 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace / Chajjas / Sunken portion of WC: Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 1012.26 | 1012.26 | 24.98 | False | None | None | False | None | False | 25286.2548 | 0 |
| 3565021 | 129284 | None | code116 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. Internal work, Conceled work, including cutting chases & making good the wall etc 15mm dia pipe in GF WC | Mtr | 382.85 | 382.85 | 15.0 | False | None | None | False | None | False | 5742.75 | 0 |
| 3565022 | 129284 | None | code117 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 25 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL. 25 mm dia pipe from borewell to terrace tank | Mtr | 40.0 | 40.0 | 15.0 | False | None | None | False | None | False | 600.0 | 0 |
| 3565023 | 129284 | None | code118 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 32 MM conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. including cutting chases & making good the wall etc. EXPOSED ON WALL 32mm dia pipe from terrace tank TO GF | Mtr | 495.6 | 495.6 | 10.0 | False | None | None | False | None | False | 4956.0 | 0 |
| 3565024 | 129284 | None | code119 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 88 g | Nos | 195.76 | 195.76 | 9.0 | False | None | None | False | None | False | 1761.84 | 0 |
| 3565025 | 129284 | None | code120 | Concealed stop cock, 15 mm nominal bore, 108 mm long, weighing not less than 108 gms | Nos | 249.04 | 249.04 | 7.0 | False | None | None | False | None | False | 1743.28 | 0 |
| 3565026 | 129284 | None | code121 | Providing and fixing Brass full way valve gate with C.I. wheel of Approved quality (screwed end) | Nos | 680.21 | 680.21 | 4.0 | False | None | None | False | None | False | 2720.84 | 0 |
| 3565027 | 129284 | None | code122 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. | Unit | 2844.74 | 2844.74 | 3.0 | False | None | None | False | None | False | 8534.22 | 0 |
| 3565028 | 129284 | None | code123 | 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms | Nos | 389.04 | 389.04 | 4.0 | False | None | None | False | None | False | 1556.16 | 0 |
| 3565029 | 129284 | None | code124 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length | Unit | 112.74 | 112.74 | 3.0 | False | None | None | False | None | False | 338.22 | 0 |
| 3565030 | 129284 | None | code125 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. | Each | 337.0 | 337.0 | 2.0 | False | None | None | False | None | False | 674.0 | 0 |
| 3565031 | 129284 | None | code126 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Unit | 1511.58 | 1511.58 | 3.0 | False | None | None | False | None | False | 4534.74 | 0 |
| 3565032 | 129284 | None | code127 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required | Pan | 7405.5 | 7405.5 | 2.0 | False | None | None | False | None | False | 14811.0 | 0 |
| 3565033 | 129284 | None | code128 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia | Each | 113.98 | 113.98 | 3.0 | False | None | None | False | None | False | 341.94 | 0 |
| 3565034 | 129284 | None | code129 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushin cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two squatting plates with 5 litre P.V.C. automatic flushin cistern | Each | 16036.37 | 16036.37 | 2.0 | False | None | None | False | None | False | 32072.74 | 0 |
| 3565035 | 129284 | None | code130 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 477.01 | 477.01 | 37.92 | False | None | None | False | None | False | 18088.2192 | 0 |
| 3565036 | 129284 | None | code131 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 4.13 | False | None | None | False | None | False | 4748.6327 | 0 |
| 3565037 | 129284 | None | code132 | KSRB 13-11.1 : Providing and placing on terrace,(at all floor levels) polyethylene water storage tank is:12701 marked with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.- | Ltr | 11.15 | 11.15 | 1000.0 | False | None | None | False | None | False | 11150.0 | 0 |
| 3565038 | 129284 | None | code133 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia. | Mtr | 356.83 | 356.83 | 15.0 | False | None | None | False | None | False | 5352.45 | 0 |
| 3565039 | 129284 | None | code134 | STAINLESS STEEL GRAB BAR STEEL HANDE SIZE (48" inchs) Market Rate Rs.400 | Rft | 472.0 | 472.0 | 4.0 | False | None | None | False | None | False | 1888.0 | 0 |
| 3565040 | 129284 | None | code135 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet* Sand Cast Iron S&S as per IS: 1729 Wash Basins | Each | 1418.65 | 1418.65 | 3.0 | False | None | None | False | None | False | 4255.95 | 0 |
| 3565041 | 129284 | None | code136 | Supplying heavy gauge PVC conduit pipe ...2. mm dia.....25...mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Rmtr | 92.04 | 92.04 | 35.0 | False | None | None | False | None | False | 3221.4 | 0 |
| 3565042 | 129284 | None | code137 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. | Rmtr | 34.22 | 34.22 | 15.0 | False | None | None | False | None | False | 513.3 | 0 |
| 3565043 | 129284 | None | code138 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. GROUP short point up to 3 mtr from tapping point out let via switch | Each | 336.3 | 336.3 | 3.0 | False | None | None | False | None | False | 1008.9 | 0 |
| 3565044 | 129284 | None | code139 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Each | 464.92 | 464.92 | 5.0 | False | None | None | False | None | False | 2324.6 | 0 |
| 3565045 | 129284 | None | code140 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 | Each | 173.46 | 173.46 | 3.0 | False | None | None | False | None | False | 520.38 | 0 |
| 3565046 | 129284 | None | code141 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way | Each | 376.42 | 376.42 | 3.0 | False | None | None | False | None | False | 1129.26 | 0 |
| 3565047 | 129284 | None | code142 | 4-5 way | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 |
| 3565048 | 129284 | None | code143 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 modular | Each | 206.5 | 206.5 | 1.0 | False | None | None | False | None | False | 206.5 | 0 |
| 3565049 | 129284 | None | code144 | 12 module | Each | 405.92 | 405.92 | 3.0 | False | None | None | False | None | False | 1217.76 | 0 |
| 3565050 | 129284 | None | code145 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired.Excluding Ballast & Fluorescent Tube | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 |
| 3565051 | 129284 | None | code146 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SP | Each | 490.88 | 490.88 | 2.0 | False | None | None | False | None | False | 981.76 | 0 |
| 3565052 | 129284 | None | code147 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming latest amanment 2.5 sq mm | Rmtr | 49.56 | 49.56 | 50.0 | False | None | None | False | None | False | 2478.0 | 0 |
| 3565053 | 129284 | None | code148 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12' sweep (300mm) | Each | 3503.42 | 3503.42 | 3.0 | False | None | None | False | None | False | 10510.26 | 0 |
| 3565054 | 129284 | None | code149 | Fixing one exhaust fan inthenitchal ready leftint hewall with bolts and nuts and 5A.c ceiling rose with sufficient length of 23/0.0076inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 3.0 | False | None | None | False | None | False | 1741.68 | 0 |
| 3565055 | 129284 | None | code150 | Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 12.39 | 12.39 | 217.92 | False | None | None | False | None | False | 2700.0288 | 0 |
| 3565056 | 129284 | None | code151 | Providing fresh lime plaster to brick masonry of 10mm lime mortar (slaked lime : sand) 1:2 proportion as base coat and finishing coat of 10mm of lime mortar (slaked lime : sand) 1:1 proportion including rounding or chamfering corners, arrises, junctions, etc wherever required smooth rendering, including jute netting, lead charges for lime and sand, lift charges above 3mt height providing and removing scaffolding, grinding machine, cost of materials, labour, curing etc., The dashing of the first coat to be done using a strong whipping motion at right angles to the face of the wall. The plaster shall be trowelled hard and tight forcing it into joints to obtain a good bond and surface rubbed smooth with a plaster’s trowel complete as per specification and IS 2394 (1984). Curing shall be started 24 hrs after finishing the plaster. The plaster shall be kept wet for a period of 7 days etc complete as per direction of the Engineer in charge of the work. | Sqm | 1237.76 | 1237.76 | 252.38 | False | None | None | False | None | False | 312385.8688 | 0 |
| 3565057 | 129284 | None | code152 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 597.19 | 597.19 | 18.35 | False | None | None | False | None | False | 10958.4365 | 0 |
| 3565058 | 129284 | None | code153 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 224.26 | 224.26 | 390.98 | False | None | None | False | None | False | 87681.1748 | 0 |
| 3565059 | 129284 | None | code154 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 127.58 | False | None | None | False | None | False | 16122.2846 | 0 |
| 3565060 | 129284 | None | code155 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 1113.82 | False | None | None | False | None | False | 654124.2096 | 0 |
| 3565061 | 129284 | None | code156 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) bed concrete | Cum | 7702.86 | 7702.86 | 14.2 | False | None | None | False | None | False | 109380.612 | 0 |
| 3565062 | 129284 | None | code157 | PCC top UCRS masonry for pedestals | Cum | 7702.86 | 7702.86 | 8.48 | False | None | None | False | None | False | 65320.2528 | 0 |
| 3565063 | 129284 | None | code158 | PCC top UCRS masonry for basement | Cum | 7702.86 | 7702.86 | 2.76 | False | None | None | False | None | False | 21259.8936 | 0 |
| 3565064 | 129284 | None | code159 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with. Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6952.02 | 6952.02 | 66.01 | False | None | None | False | None | False | 458902.8402 | 0 |
| 3565065 | 129284 | None | code160 | UCRS Stone Masonary (foundation) | Cum | 6952.02 | 6952.02 | 22.67 | False | None | None | False | None | False | 157602.2934 | 0 |
| 3565066 | 129284 | None | code161 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 10173.42 | 10173.42 | 29.16 | False | None | None | False | None | False | 296656.9272 | 0 |
| 3565067 | 129284 | None | code162 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 477.01 | 477.01 | 160.15 | False | None | None | False | None | False | 76393.1515 | 0 |
| 3565068 | 129284 | None | code163 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 2027.0 | 2027.0 | 1768.38 | False | None | None | False | None | False | 3584506.26 | 0 |
| 3565069 | 129284 | None | code164 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 61.95 | 61.95 | 184.1 | False | None | None | False | None | False | 11404.995 | 0 |
| 3565070 | 129284 | None | code165 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 172.22 | 172.22 | 184.1 | False | None | None | False | None | False | 31705.702 | 0 |
| 3565071 | 129284 | None | code166 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 1012.26 | 1012.26 | 160.15 | False | None | None | False | None | False | 162113.439 | 0 |
| 3565072 | 129284 | None | code167 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge. | Cum | 2086.47 | 2086.47 | 3.92 | False | None | None | False | None | False | 8178.9624 | 0 |
| 3565073 | 129284 | None | code168 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 7702.86 | 7702.86 | 20.38 | False | None | None | False | None | False | 156984.2868 | 0 |
| 3565074 | 129284 | None | code169 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire ornuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (Made of G.I. wire of dia 4 mm) | Sqm | 994.92 | 994.92 | 243.38 | False | None | None | False | None | False | 242143.6296 | 0 |
| 3565075 | 129284 | None | code170 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications andas per directions of the Engineer-in-Charge. Vertical & Horizontal supporting pipes &base plate | Kgs | 168.5 | 168.5 | 2371.23 | False | None | None | False | None | False | 399552.255 | 0 |
| 3565076 | 129284 | None | code171 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kgs | 208.15 | 208.15 | 1781.23 | False | None | None | False | None | False | 370763.0245 | 0 |
| 3565077 | 129284 | None | code172 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 3005.81 | 3005.81 | 2.14 | False | None | None | False | None | False | 6432.4334 | 0 |
| 3565078 | 129284 | None | code173 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 117.7 | 117.7 | 3.46 | False | None | None | False | None | False | 407.242 | 0 |
| 3565079 | 129284 | None | code174 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 7702.86 | 7702.86 | 2.25 | False | None | None | False | None | False | 17331.435 | 0 |
| 3565080 | 129284 | None | code175 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications andas per directions of the Engineer-in-Charge. Vertical & Horizontal supporting pipes &base plate | Kgs | 168.5 | 168.5 | 523.83 | False | None | None | False | None | False | 88265.355 | 0 |
| 3565081 | 129284 | None | code176 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finishe with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Curved Portion | Sqm | 5877.81 | 5877.81 | 23.3 | False | None | None | False | None | False | 136952.973 | 0 |
| 3565082 | 129284 | None | code177 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 112.11 | False | None | None | False | None | False | 14167.3407 | 0 |
| 3565083 | 129284 | None | code178 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 112.11 | False | None | None | False | None | False | 65839.9608 | 0 |
| 3565084 | 129284 | None | code179 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | Sqm | 991.2 | 991.2 | 747.38 | False | None | None | False | None | False | 740803.056 | 0 |
| 3565085 | 129284 | None | code180 | Supplying and fixing M15 grade precast cement concrete Kerb stones 600 x 300 x 150 mm Kerb Stone for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) | Mtr | 573.66 | 573.66 | 731.62 | False | None | None | False | None | False | 419701.1292 | 0 |
| 3565086 | 129284 | None | code181 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7735.07 | 7735.07 | 80.1 | False | None | None | False | None | False | 619579.107 | 0 |
| 3565087 | 129284 | None | code182 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. | Sqm | 135.05 | 135.05 | 219.49 | False | None | None | False | None | False | 29642.1245 | 0 |
| 3565088 | 129284 | None | code183 | Scrapping gandrmovingtopsoil: Scrapping the area by removing 0.15m soil land removing of unwnted plants, grassalong with roots. 25Km initial transport, including leact, lift loading and unloading charges (1x1x0.15mt). 1st digging of the area for developing lawn including removing weeds, debris if any and breaking of clumps, wteringetc. (1x1x0.45mt). Procurment of quality red earth/soil and heap around pit (1x1x0.45mtr). supplying of inputs suchass and FYM, Redearthin 1:3:6 ratio, mixing and spreading the Red soil 0.0075m3, Farm yard manure 0.0225m3, sand 0.045m3, Supply of feritiliser:1m2, Super Phosphate 50gram, Neem oil cake, 250 gram, bone meal:250gram, potash:50gram, Furadan 25gram, Ammonium suplphate 100 gram, Chlorophynphas 0.05 mill.ltr, Procurement of quality lawn grass. | Sqm | 724.81 | 724.81 | 600.0 | False | None | None | False | None | False | 434886.0 | 0 |
| 3565089 | 129284 | None | code184 | clearing of land by cutting of thick and sparse growth plants 0.25m thickness plants and clearing of bushes along with roots throwing away to 1.5mtr height and 50 mtr far) items nM.12.1 (a) Birnak siuk, | Sqm | 8.36 | 8.36 | 600.0 | False | None | None | False | None | False | 5016.0 | 0 |
| 3565090 | 129284 | None | code185 | Digging pits of size 0.45x0.45x0.45 n fukkubg 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion of sand (0.007) FYM (0.014cm) red earth (0.021cm) and planting of well grown tree saplings (excluding cost of plants) | Nos | 80.24 | 80.24 | 200.0 | False | None | None | False | None | False | 16048.0 | 0 |
| 3565091 | 129284 | None | code186 | Planting of shrubs- as per the choice ofEngineer incharge and consultants. | Nos | 30.97 | 30.97 | 201.0 | False | None | None | False | None | False | 6224.97 | 0 |
| 3565092 | 129284 | None | code187 | Planting of creepers- Digging pits of size 0.45x0.45x0.45 n fukkubg 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion of sand (0.007) FYM (0.014cm) red earth (0.021cm) and planting of well grown tree saplings (excluding cost of plants) | Nos | 84.25 | 84.25 | 200.0 | False | None | None | False | None | False | 16850.0 | 0 |
| 3565093 | 129284 | None | code188 | Cost of plants- As per the choice of Engineer incharge and consultants as per market rate | Nos | 30.97 | 30.97 | 200.0 | False | None | None | False | None | False | 6194.0 | 0 |
| 3565094 | 129284 | None | code189 | Planting of ground cover plants - Digging pits of size 0.45x0.45x0.45 n fukkubg 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion of sand (0.007) FYM (0.014cm) red earth (0.021cm) and planting of well grown tree saplings (excluding cost of plants)n (Normal soil) | Nos | 392.76 | 392.76 | 200.0 | False | None | None | False | None | False | 78552.0 | 0 |
| 3565095 | 129284 | None | code190 | Cost of plants - As per the choice of Engineer incharge and consultants as per market rate | Nos | 12.39 | 12.39 | 200.0 | False | None | None | False | None | False | 2478.0 | 0 |
| 3565096 | 129284 | None | code191 | Rose garden/growing of rose plants - Digging pits of size 0.6x0.6x0.6 n fukkubg 50% of the pit with top soil and remaining 50% of pit with 1:6:6 proportion of sand (0.008) FYM (0.0148cm) red earth (0.048cm)neem oil cake (200 gm) bonemeal (100gm) ginaliol (100gm), Suphalal (10gMs) Reosems (5gms) and other plant protectoic. | Nos | 219.3 | 219.3 | 200.0 | False | None | None | False | None | False | 43860.0 | 0 |
| 3565097 | 129284 | None | code192 | Cost of plants - As per the choice of Engineer incharge and consultants as per market rate | Nos | 92.92 | 92.92 | 200.0 | False | None | None | False | None | False | 18584.0 | 0 |
| 3565098 | 129284 | None | code193 | Growing of flower bed - Digging pits of size1.0x1.0x0.45m fukkubg 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion of sand (0.0375) FYM (0.0075cm) red earth (0.0112cum) and planting well growth saplings/plants/(Excluding cost of plants) | Nos | 392.76 | 392.76 | 200.0 | False | None | None | False | None | False | 78552.0 | 0 |
| 3565099 | 129284 | None | code194 | Cost of plants- As per the choice of Engineer incharge and consultants as per market rate | Nos | 61.95 | 61.95 | 200.0 | False | None | None | False | None | False | 12390.0 | 0 |
| 3565100 | 129284 | None | code195 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth CPVC Pipe for Gardening | Cum | 117.7 | 117.7 | 135.0 | False | None | None | False | None | False | 15889.5 | 0 |
| 3565101 | 129284 | None | code196 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenc External work 50mm nominal dia pipes work of building | Mtr | 893.31 | 893.31 | 300.0 | False | None | None | False | None | False | 267993.0 | 0 |
| 3565102 | 129284 | None | code197 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenc External work 25mm nominal dia pipes work of building | Mtr | 366.74 | 366.74 | 200.0 | False | None | None | False | None | False | 73348.0 | 0 |
| 3565103 | 129284 | None | code198 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25mm nominal bore | Nos | 411.34 | 411.34 | 30.0 | False | None | None | False | None | False | 12340.2 | 0 |
| 3565104 | 129284 | None | code199 | French spirit polishing :Two coats on new works including a coat of wood filler to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 286.2 | 286.2 | 596.97 | False | None | None | False | None | False | 170852.814 | 0 |
| 3565105 | 129284 | None | code200 | Providing and Labelling the Existing sculptures including cost of materials, labour, conveyence charges etc., complete as per the direction of engineer incharge of the work. | Nos | 1534.0 | 1534.0 | 325.0 | False | None | None | False | None | False | 498550.0 | 0 |
| 3565106 | 129284 | None | code201 | Removing the glazed tiles in patches in area exceeding 10 tiles and not exceeding 5 sqm including removing old tiles preparing surfaces and laying or setting new or old tiles complete including cost of materials, excluding cost of tiles ) labour, complete as per specifications. | Sqm | 1413.69 | 1413.69 | 23.2 | False | None | None | False | None | False | 32797.608 | 0 |
| 3565107 | 129284 | None | code202 | Providing and erecting direction and place identification retro reflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area exceeding 0.9 m2 fixed over back support frame of min 40 x 40 x 5mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing | Sqm | 12020.77 | 12020.77 | 12.0 | False | None | None | False | None | False | 144249.24 | 0 |
| 3565108 | 129284 | None | code203 | Supplying and Fixing of Designer Inter locking Concrete garden benches including cost of materials, labour, usage charges of machinery complete as per specifications | Set | 7080.0 | 7080.0 | 40.0 | False | None | None | False | None | False | 283200.0 | 0 |