| 3561735 | 129057 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated nsurfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredto complete the work In all kinds of soils. Depth upto 1.50m | Cum | 458.7 | 458.7 | 50.0 | False | None | None | False | None | False | 22935.0 | 0 |
| 3561736 | 129057 | None | 2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately).Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5726.6 | 5726.6 | 4.0 | False | None | None | False | None | False | 22906.4 | 0 |
| 3561737 | 129057 | None | 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7892.28 | 7892.28 | 15.0 | False | None | None | False | None | False | 118384.2 | 0 |
| 3561738 | 129057 | None | 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 217.8 | 217.8 | 25.0 | False | None | None | False | None | False | 5445.0 | 0 |
| 3561739 | 129057 | None | 19.7.1 | Demolishing brick work manually/ by mechanical means including
stacking of serviceable material and disposal of unserviceable material
to the appropriate disposal area as per direction of Engineer-in-charge
| Cum | 405.9 | 405.9 | 5.0 | False | None | None | False | None | False | 2029.5 | 0 |
| 3561740 | 129057 | None | 15.4 | Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400% and having solid content of above 90% @ 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g/ m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction ofthe Engineer In charge | Sqm | 876.7 | 876.7 | 25.0 | False | None | None | False | None | False | 21917.5 | 0 |
| 3561741 | 129057 | None | 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 149.6 | 149.6 | 5200.0 | False | None | None | False | None | False | 777920.0 | 0 |
| 3561742 | 129057 | None | 7.1.1 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 874.5 | 874.5 | 40.0 | False | None | None | False | None | False | 34980.0 | 0 |
| 3561743 | 129057 | None | 11.32 | 2 Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 96.8 | 96.8 | 750.0 | False | None | None | False | None | False | 72600.0 | 0 |
| 3561744 | 129057 | None | 8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.0 | 143.0 | 250.0 | False | None | None | False | None | False | 35750.0 | 0 |
| 3561745 | 129057 | None | 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 149.6 | 149.6 | 200.0 | False | None | None | False | None | False | 29920.0 | 0 |
| 3561746 | 129057 | None | 10.15.1 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc.,For Curved Portion complete | Sqm | 4332.9 | 4332.9 | 90.0 | False | None | None | False | None | False | 389961.0 | 0 |
| 3561747 | 129057 | None | 16.4 | Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc. and Electrical Inspectrate approval Without Machine Room-SS Finish Capacity-20 passenger | Set | 2542200.0 | 2542200.0 | 1.0 | False | None | None | False | None | False | 2542200.0 | 0 |
| 3561748 | 129057 | None | 11.3.3 | Supplying of 1X4 feet - PVC Batten with integrated LED tube.36/40 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionLED light fighting 1x 4 - 36 /40 w | Each | 1197.0 | 1197.0 | 8.0 | False | None | None | False | None | False | 9576.0 | 0 |
| 3561749 | 129057 | None | 6.2.2 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450mm) | Each | 4126.0 | 4126.0 | 2.0 | False | None | None | False | None | False | 8252.0 | 0 |
| 3561750 | 129057 | None | 2.2.1 | Point wiring using Copper wire without switch.:- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch box | Point | 251.0 | 251.0 | 4.0 | False | None | None | False | None | False | 1004.0 | 0 |
| 3561751 | 129057 | None | 2.2.2 | Point wiring using Copper wire without switch.:- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 361.0 | 361.0 | 2.0 | False | None | None | False | None | False | 722.0 | 0 |
| 3561752 | 129057 | None | 2.2.3 | Point wiring using Copper wire without switch.:- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 542.0 | 542.0 | 4.0 | False | None | None | False | None | False | 2168.0 | 0 |
| 3561753 | 129057 | None | 2.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm | Mtr | 40.0 | 40.0 | 100.0 | False | None | None | False | None | False | 4000.0 | 0 |
| 3561754 | 129057 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm | Mtr | 59.0 | 59.0 | 200.0 | False | None | None | False | None | False | 11800.0 | 0 |
| 3561755 | 129057 | None | 1.1.1 | Open Conduit System:- Supplying heavy gauge PVC conduit pipe19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws | Mtr | 68.0 | 68.0 | 50.0 | False | None | None | False | None | False | 3400.0 | 0 |
| 3561756 | 129057 | None | 1.1.2 | Supplying heavy gauge PVC conduit pipe125mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws | Mtr | 80.0 | 80.0 | 50.0 | False | None | None | False | None | False | 4000.0 | 0 |
| 3561757 | 129057 | None | RMR | Suplying and fixing lift control board including, ammeter, volt meter, CTs, LED indicators, ELCB, MCB'S enclosed in MS sheet box including lead, lift, transportation, labour charges, completed as per the in-charge engineer | LS | 65000.0 | 65000.0 | 1.0 | False | None | None | False | None | False | 65000.0 | 0 |
| 3561758 | 129057 | None | 5.14.7 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics)100Amps 25kA | Each | 8265.0 | 8265.0 | 3.0 | False | None | None | False | None | False | 24795.0 | 0 |
| 3561759 | 129057 | None | 5.14.14 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics)500-630Amps 50kA | Each | 39465.0 | 39465.0 | 4.0 | False | None | None | False | None | False | 157860.0 | 0 |
| 3561760 | 129057 | None | 5.14.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics)700-800Amps 50kA | Each | 43524.0 | 43524.0 | 2.0 | False | None | None | False | None | False | 87048.0 | 0 |
| 3561761 | 129057 | None | 5.15 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 1512.0 | 1512.0 | 3.0 | False | None | None | False | None | False | 4536.0 | 0 |
| 3561762 | 129057 | None | 5.16.1 | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/ three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. 4Way | Each | 9169.0 | 9169.0 | 1.0 | False | None | None | False | None | False | 9169.0 | 0 |
| 3561763 | 129057 | None | 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP | Each | 523.0 | 523.0 | 12.0 | False | None | None | False | None | False | 6276.0 | 0 |
| 3561764 | 129057 | None | 5.17.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN | Each | 2399.0 | 2399.0 | 4.0 | False | None | None | False | None | False | 9596.0 | 0 |
| 3561765 | 129057 | None | 5.19.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.63 Amps 4 pole | Each | 5039.0 | 5039.0 | 2.0 | False | None | None | False | None | False | 10078.0 | 0 |
| 3561766 | 129057 | None | 5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 8316.0 | 8316.0 | 1.0 | False | None | None | False | None | False | 8316.0 | 0 |
| 3561767 | 129057 | None | 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 8370.0 | 8370.0 | 1.0 | False | None | None | False | None | False | 8370.0 | 0 |
| 3561768 | 129057 | None | 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound | Each | 505.0 | 505.0 | 1.0 | False | None | None | False | None | False | 505.0 | 0 |
| 3561769 | 129057 | None | 5.42.1 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete 14SWG (5.42.1) | Sq CM | 0.43 | 0.43 | 200000.0 | False | None | None | False | None | False | 86000.0 | 0 |
| 3561770 | 129057 | None | 9.32-217 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) | Km | 181452.0 | 181452.0 | 0.15 | False | None | None | False | None | False | 27217.8 | 0 |
| 3561771 | 129057 | None | 9.32-228 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm) | Km | 1186071.0 | 1186071.0 | 0.25 | False | None | None | False | None | False | 296517.75 | 0 |
| 3561772 | 129057 | None | 9.31 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm | Km | 16159.0 | 16159.0 | 0.15 | False | None | None | False | None | False | 2423.85 | 0 |
| 3561773 | 129057 | None | 9.32 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staf 120 to 240 Sqmm | Km | 24148.0 | 24148.0 | 0.2 | False | None | None | False | None | False | 4829.6 | 0 |
| 3561774 | 129057 | None | 29.04-202 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soil | CUBIC METER | 389.0 | 389.0 | 180.0 | False | None | None | False | None | False | 70020.0 | 0 |
| 3561775 | 129057 | None | 20-63.03-514 | Heavy Duty Copper Terminal Long Barrel 50 sqmm Long Barrel | Each | 60.0 | 60.0 | 19.0 | False | None | None | False | None | False | 1140.0 | 0 |
| 3561776 | 129057 | None | 21.63.06-517 | Heavy Duty Copper Terminal Long Barrel 120 sqmm Long Barrel | Each | 145.0 | 145.0 | 10.0 | False | None | None | False | None | False | 1450.0 | 0 |
| 3561777 | 129057 | None | 21-63.10 | Heavy Duty Copper Terminal Long Barrel 240 sqmm Long Barrel | Each | 368.0 | 368.0 | 17.0 | False | None | None | False | None | False | 6256.0 | 0 |