createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721476651322
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee750.00
emd60000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose06-08-2024 16:00:00
tenderQueryClose29-07-2024 15:00:01
technicalBidOpen07-08-2024 16:30:00
publishedDate21-07-2024 18:56:20
publishedByPostTP_CO_TVK
publishedByUserKPE17238 - SREENATHA BABU S
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonHARISH B
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8904194602
tenderSupplierListNone
tenderSchedule
createdTs1721476651348
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT22355
titleConstruction of primary shed of Material Recovery Facility Phase for dry waste disposal at SWM plant under Turuvekere town limits
descriptionConstruction of primary shed of Material Recovery Facility Phase for dry waste disposal at SWM plant under Turuvekere town limits.
categoryWORKS
categoryTextWorks
ecv2996354.05
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2409
locationNameDMA Town Panchayat Turuvekere
provisionalAmount3000000.0
groupOverheadTotal55549.58
fileNumberTPTVK/TS/TENDER/CR-04/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17214766510002NoneNoneBuildingsConstruction of primary shed of Material Recovery Facility Phase for dry waste disposal at SWM plant under Turuvekere town limits2940804.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3568421129455None001KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum123.97123.9729.41FalseNoneNoneFalseNoneTrue3645.95770
3568422129455None002KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum6884.026884.0228.97FalseNoneNoneFalseNoneFalse199430.05940
3568423129455None003KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid seperately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)As per recommendation of technical working group rates for formwork shall be added on percentage basis to finished concrete item rate.Cum8487.58487.535.74FalseNoneNoneFalseNoneFalse303343.250
3568424129455None004KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid seperately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for column base As per recommendation of technical working group rates for formwork shall be added on percentage basis to finished concrete item rate.Cum12998.8812998.881.63FalseNoneNoneFalseNoneFalse21188.17440
3568425129455None005KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)As per recommendation of technical working group rates for formwork shall be added on percentage basis to finished concrete item rate.Cum11439.0111439.014.82FalseNoneNoneFalseNoneFalse55136.02820
3568426129455None006KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Kg108.72108.722417.1FalseNoneNoneFalseNoneFalse262787.1120
3568427129455None007KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum7765.197765.1916.67FalseNoneNoneFalseNoneFalse129445.71730
3568428129455None008KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum559.32559.32128.79FalseNoneNoneFalseNoneFalse72034.82280
3568429129455None009KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1496.151496.1591.08FalseNoneNoneFalseNoneFalse136269.3420
3568430129455None010KSRB 8-8.3.1: Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm358.54358.54187.56FalseNoneNoneFalseNoneFalse67247.76240
3568431129455None011Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg137.34137.346130.0FalseNoneNoneFalseNoneFalse841894.20
3568432129455None012Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm690.34690.34518.21FalseNoneNoneFalseNoneFalse357741.09140
3568433129455None013KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm121.54121.54187.56FalseNoneNoneFalseNoneFalse22796.04240
3568434129455None014KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm88.7288.7291.08FalseNoneNoneFalseNoneFalse8080.61760
3568435129455None015KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)Sqm88.7288.7291.08FalseNoneNoneFalseNoneFalse8080.61760
3568436129455None016KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm3200.143200.149.0FalseNoneNoneFalseNoneFalse28801.260
3568437129455None017KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No30003.3630003.361.0FalseNoneNoneFalseNoneFalse30003.360
3568438129455None018KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg549.36549.36240.0FalseNoneNoneFalseNoneFalse131846.40
3568439129455None019Supplying heavy gauge PVC conduit pipe 32 dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(Item No. 1.1.3, Page No.2 of 105,PWD Electrical SR Vol-06)m128.83128.83325.0FalseNoneNoneFalseNoneFalse41869.750
3568440129455None020Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 .(Item No. 2.5.1 60 of 105, Page No.6,PWD Electrical SR Vol-06)3C X 4 mm2m209.04209.04325.0FalseNoneNoneFalseNoneFalse67938.00
3568441129455None021Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (Item No. 3.4.5, Page No.8,PWD Electrical SR Vol-06)Each317.21317.218.0FalseNoneNoneFalseNoneFalse2537.680
3568442129455None022Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (Item No. 3.5.5, Page No.8,PWD Electrical SR Vol-06)Each345.17345.178.0FalseNoneNoneFalseNoneFalse2761.360
3568443129455None023Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.1, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 16AEach471.28471.284.0FalseNoneNoneFalseNoneFalse1885.120
3568444129455None024Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.2, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 32AEach666.13666.134.0FalseNoneNoneFalseNoneFalse2664.520
3568445129455None025Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.3, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 16AEach549.51549.514.0FalseNoneNoneFalseNoneFalse2198.040
3568446129455None026Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.4, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 32AEach741.22741.224.0FalseNoneNoneFalseNoneFalse2964.880
3568447129455None027Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.5, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 16AEach645.34645.344.0FalseNoneNoneFalseNoneFalse2581.360
3568448129455None028Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.6, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 32AEach810.72810.724.0FalseNoneNoneFalseNoneFalse3242.880
3568449129455None029Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.7, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 16AEach770.29770.294.0FalseNoneNoneFalseNoneFalse3081.160
3568450129455None030Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.8, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 32AEach1006.131006.134.0FalseNoneNoneFalseNoneFalse4024.520
3568451129455None031Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.1, Page No.10,PWD Electrical SR Vol-06) 6A SP SwitchNo66.8466.8432.0FalseNoneNoneFalseNoneFalse2138.880
3568452129455None032Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.10, Page No.10,PWD Electrical SR Vol-06) 16A SP SwitchNo85.0785.078.0FalseNoneNoneFalseNoneFalse680.560
3568453129455None033Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.10, Page No.10,PWD Electrical SR Vol-06) 16A SP SwitchNo159.21159.218.0FalseNoneNoneFalseNoneFalse1273.680
3568454129455None034Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.12, Page No.10,PWD Electrical SR Vol-06) 16A Three Way 5 Pin SocketNo139.77139.778.0FalseNoneNoneFalseNoneFalse1118.160
3568455129455None035Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.14, Page No.10,PWD Electrical SR Vol-06) 32A Bakelite DPNo281.97281.978.0FalseNoneNoneFalseNoneFalse2255.760
3568456129455None036Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.15, Page No.10,PWD Electrical SR Vol-06) 16/6A combined plug and socket with control switchNo264.95264.958.0FalseNoneNoneFalseNoneFalse2119.60
3568457129455None037Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.,6-32 A SP(Item No. 5.18.1, Page No.17,PWD Electrical SR Vol-06)Each504.39504.398.0FalseNoneNoneFalseNoneFalse4035.120
3568458129455None038Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws,(Item No. 3.8, Page No.9,PWD Electrical SR Vol-06)Sq CM0.50.54800.0FalseNoneNoneFalseNoneFalse2400.00
3568459129455None039Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 50 kA (Item No. 5.15.8, Page No.16,PWD Electrical SR Vol-06)Each30505.3230505.321.0FalseNoneNoneFalseNoneFalse30505.320
3568460129455None040Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 4 Way (Item No. 5.17.1, Page No.16,PWD Electrical SR Vol-06)Each12553.8612553.861.0FalseNoneNoneFalseNoneFalse12553.860
3568461129455None041Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA 16 - 32 A SP (Item No. 5.46.1, Page No.21,PWD Electrical SR Vol-06)Each255.23255.238.0FalseNoneNoneFalseNoneFalse2041.840
3568462129455None042Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 percentage, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. (Item No. 11.9.1, Page No.46,PWD Electrical SR Vol-06) LED Floodlight 70WEach8225.828225.828.0FalseNoneNoneFalseNoneFalse65806.560
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17214766520000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17214766520000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17214766520000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17214766520000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17214766520000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17214767010000NoneNoneELIGIBILITY1)Any discrepancy in the specification and unit of measurement the specification and unit given in Common SR issued by the PWD will prevail.None
17214767150000NoneNoneELIGIBILITY2)All rates given in BOQ are inclusive of all taxes like GST etc., Bidder should quote including all taxes etc.None
17214767390000NoneNoneELIGIBILITY3)Turnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsNone
17214767730000NoneNoneELIGIBILITYCorrigendum / modifications / correction, if any, will be published in the e-portal only.None
17214767880000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17214768120000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17214768320000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17214768500000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17214768720000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27-07-2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund.None
17214769070000NoneNoneELIGIBILITYThe Employer reserves The Tenderer shall scan Original Workdone certificates / Turnover Statements and any other documents specified by the employer and attach the scanned file to the Bid. The Original Documents shall be produced for physical verification within one week from the date of Technical bid opening.None
17214769270000NoneNoneELIGIBILITYthe right to reject any or all Tenders without assigning any reason or what so everNone
17214769430000NoneNoneELIGIBILITYThe earnest money deposit will be forfeited if the documents submitted by the tenderer found to be misleading/forged or fake .None
17214769580000NoneNoneELIGIBILITYFinancial values of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2024-25.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneTenderer in his name should have in the last five years i.e., 2019 to 2023-24,, satisfactory completed, at least one similar Building work/ Shed work of value not less than Rs.15.00 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year in the last five years i.e., 2019-20 to 2023-24, the following minimum quantities of work 1.Cement Concrete ( Plain & Reinforced)- 56.92 cum, 2. AC Sheet- 414.56 sqm, 3. Reinforcement / Structural steel work-6.84 TonnePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs. 9.00 Lakhs (Credit lines / Letters of Credit / Certificates from Banks) for meeting the fund requirement etc., (Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNonePWD Registration certificate Class3 and above (Civil) issued by Competent authorityCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTenderer in his name should have in the last five years i.e.2019-20 to 2023-24,achieved in at least two financial years an average annual financial turnover of Rs.30 lakhs.Financial StatusAnnual turnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Tenderer in his name should have in the last five years i.e.2019-20 to 2023-24,achieved in at least two financial years an average annual financial turnover of Rs.30 lakhsTrueTechnical Bid
PWD Registration Certificate Class-3 and above CivilTrueTechnical Bid
Tenderer in his name should have in the last five years i.e., 2019 to 2023-24,, satisfactory completed, at least one similar Building work/ Shed work of value not less than Rs.15.00 Lakhs as prime contractor.TrueTechnical Bid
Executed in any one year in the last five years i.e., 2019-20 to 2023-24, the following minimum quantities of work 1.Cement Concrete Plain & Reinforced- 56.92 cum, 2. AC Sheet- 414.56 sqm, 3. Reinforcement or Structural steel work-6.84 TonneTrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than Rs. 9.00 Lakhs Credit lines / Letters of Credit / Certificates from Banks for meeting the fund requirement etc., Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etcTrueTechnical Bid
GST Registration Certificate And PANTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsTumakuruTuruvekereTumkurTURUVEKERESWM PLANT TURUVEKERENoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone