createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721532539415
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee750.00
emd60000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose06-08-2024 16:00:04
tenderQueryClose29-07-2024 15:00:34
technicalBidOpen07-08-2024 16:22:29
publishedDate21-07-2024 18:35:32
publishedByPostTP_CO_KTG
publishedByUserKPE13689 - BHAGYAMMA N
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMurulidhar M R
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8310834192
tenderSupplierListNone
tenderSchedule
createdTs1721532539456
version5
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT22619
titlePrimary Shed Construction Work for Material Recovery Facility Phase 1 in Koratagere TP
descriptionPrimary Shed Construction Work for Material Recovery Facility Phase 1 in Koratagere TP
categoryWORKS
categoryTextWorks
ecv3000000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2407
locationNameDMA Town Panchayat Koratagere
provisionalAmount3000000.0
groupOverheadTotal55549.58
fileNumberKRT/SWM/MRF/02/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17215325390000NoneNoneBuildingsPrimary Shed Construction Work for Material Recovery Facility Phase 1 in Koratagere TP2944450.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3570617129656None001KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) ---- etc, including all lead and liftsCum123.97123.9729.41FalseNoneNoneFalseNoneFalse3645.95770
3570618129656None002KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR) ---- etc, including all lead and liftsCum6884.026884.0228.97FalseNoneNoneFalseNoneFalse199430.05940
3570619129656None003KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid seperately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)As per recommendation of technical working group rates for formwork shall be added on percentage basis to finished concrete item rate. ---- etc, including all lead and liftsCum8487.58487.535.74FalseNoneNoneFalseNoneFalse303343.250
3570620129656None004KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid seperately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) for column base As per recommendation of technical working group rates for formwork shall be added on percentage basis to finished concrete item rate. ---- etc, including all lead and liftsCum12998.8812998.881.63FalseNoneNoneFalseNoneFalse21188.17440
3570621129656None005KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)As per recommendation of technical working group rates for formwork shall be added on percentage basis to finished concrete item rate. ---- etc, including all lead and liftsCum11439.0111439.014.82FalseNoneNoneFalseNoneFalse55136.02820
3570622129656None006KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR) ---- etc, including all lead and liftsKg108.72108.722417.1FalseNoneNoneFalseNoneFalse262787.1120
3570623129656None007KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) ---- etc, including all lead and liftsCum7765.197765.1916.67FalseNoneNoneFalseNoneFalse129445.71730
3570624129656None008KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) ---- etc, including all lead and liftsCum559.32559.32128.79FalseNoneNoneFalseNoneFalse72034.82280
3570625129656None009KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) ---- etc, including all lead and liftsSqm1496.151496.1591.08FalseNoneNoneFalseNoneFalse136269.3420
3570626129656None010KSRB 8-8.3.1: Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2) ---- etc, including all lead and liftsSqm358.54358.54187.56FalseNoneNoneFalseNoneFalse67247.76240
3570627129656None011Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) ---- etc, including all lead and liftsKg137.34137.346130.0FalseNoneNoneFalseNoneFalse841894.20
3570628129656None012Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) ---- etc, including all lead and liftsSqm690.34690.34518.21FalseNoneNoneFalseNoneFalse357741.09140
3570629129656None013KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2) ---- etc, including all lead and liftsSqm121.54121.54187.56FalseNoneNoneFalseNoneFalse22796.04240
3570630129656None014KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) ---- etc, including all lead and liftsSqm88.7288.7291.08FalseNoneNoneFalseNoneFalse8080.61760
3570631129656None015KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2) ---- etc, including all lead and liftsSqm88.7288.7291.08FalseNoneNoneFalseNoneFalse8080.61760
3570632129656None016KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) ---- etc, including all lead and liftsSqm3200.143200.149.0FalseNoneNoneFalseNoneFalse28801.260
3570633129656None017KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) ---- etc, including all lead and liftsNo30003.3630003.361.0FalseNoneNoneFalseNoneFalse30003.360
3570634129656None018KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2) ---- etc, including all lead and liftsKg549.36549.36240.0FalseNoneNoneFalseNoneFalse131846.40
3570635129656None019Supplying heavy gauge PVC conduit pipe 32 dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(Item No. 1.1.3, Page No.2 of 105,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsm128.83128.83325.0FalseNoneNoneFalseNoneFalse41869.750
3570636129656None020Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 .(Item No. 2.5.1 60 of 105, Page No.6,PWD Electrical SR Vol-06)3C X 4 mm2 ---- etc, including all lead and liftsm209.04209.04325.0FalseNoneNoneFalseNoneFalse67938.00
3570637129656None021Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (Item No. 3.4.5, Page No.8,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsEach317.21317.218.0FalseNoneNoneFalseNoneFalse2537.680
3570638129656None022Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (Item No. 3.5.5, Page No.8,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsEach345.17345.178.0FalseNoneNoneFalseNoneFalse2761.360
3570639129656None023Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.1, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 16A ---- etc, including all lead and liftsEach471.28471.284.0FalseNoneNoneFalseNoneFalse1885.120
3570640129656None024Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.2, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 32A ---- etc, including all lead and liftsEach666.13666.134.0FalseNoneNoneFalseNoneFalse2664.520
3570641129656None025Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.3, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 16A ---- etc, including all lead and liftsEach549.51549.514.0FalseNoneNoneFalseNoneFalse2198.040
3570642129656None026Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.4, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 32A ---- etc, including all lead and liftsEach741.22741.224.0FalseNoneNoneFalseNoneFalse2964.880
3570643129656None027Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.5, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 16A ---- etc, including all lead and liftsEach645.34645.344.0FalseNoneNoneFalseNoneFalse2581.360
3570644129656None028Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.6, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 32A ---- etc, including all lead and liftsEach810.72810.724.0FalseNoneNoneFalseNoneFalse3242.880
3570645129656None029Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.7, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 16A ---- etc, including all lead and liftsEach770.29770.294.0FalseNoneNoneFalseNoneFalse3081.160
3570646129656None030Supplying and fixing of metal clad industrial plugs and sockets. ,(Item No. 3.13.8, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 32A ---- etc, including all lead and liftsEach1006.131006.134.0FalseNoneNoneFalseNoneFalse4024.520
3570647129656None031Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.1, Page No.10,PWD Electrical SR Vol-06) 6A SP Switch ---- etc, including all lead and liftsNo66.8466.8432.0FalseNoneNoneFalseNoneFalse2138.880
3570648129656None032Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.10, Page No.10,PWD Electrical SR Vol-06) 16A SP Switch ---- etc, including all lead and liftsNo85.0785.078.0FalseNoneNoneFalseNoneFalse680.560
3570649129656None033Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.10, Page No.10,PWD Electrical SR Vol-06) 16A SP Switch ---- etc, including all lead and liftsNo159.21159.218.0FalseNoneNoneFalseNoneFalse1273.680
3570650129656None034Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.12, Page No.10,PWD Electrical SR Vol-06) 16A Three Way 5 Pin Socket ---- etc, including all lead and liftsNo139.77139.778.0FalseNoneNoneFalseNoneFalse1118.160
3570651129656None035Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.14, Page No.10,PWD Electrical SR Vol-06) 32A Bakelite DP ---- etc, including all lead and liftsNo281.97281.978.0FalseNoneNoneFalseNoneFalse2255.760
3570652129656None036Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(Item No. 3.14.15, Page No.10,PWD Electrical SR Vol-06) 16/6A combined plug and socket with control switch ---- etc, including all lead and liftsNo264.95264.958.0FalseNoneNoneFalseNoneFalse2119.60
3570653129656None037Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.,6-32 A SP(Item No. 5.18.1, Page No.17,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsEach504.39504.398.0FalseNoneNoneFalseNoneFalse4035.120
3570654129656None038Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws,(Item No. 3.8, Page No.9,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsSq CM0.50.54800.0FalseNoneNoneFalseNoneFalse2400.00
3570655129656None039Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 50 kA (Item No. 5.15.8, Page No.16,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsEach30505.3230505.321.0FalseNoneNoneFalseNoneFalse30505.320
3570656129656None040Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 4 Way (Item No. 5.17.1, Page No.16,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsEach12553.8612553.861.0FalseNoneNoneFalseNoneFalse12553.860
3570657129656None041Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA 16 - 32 A SP (Item No. 5.46.1, Page No.21,PWD Electrical SR Vol-06) ---- etc, including all lead and liftsEach255.23255.238.0FalseNoneNoneFalseNoneFalse2041.840
3570658129656None042Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 percentage, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with . W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. (Item No. 11.9.1, Page No.46,PWD Electrical SR Vol-06) LED Floodlight 70W ---- etc, including all lead and liftsEach8225.828225.828.0FalseNoneNoneFalseNoneFalse65806.560
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17215325410000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17215325410000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17215325410001NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17215325410000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17215325410000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17215326270000NoneNoneELIGIBILITYAny discrepancy in the specification and unit of measurement the specification and unit given in Common SR issued by the PWD will prevailNone
17215326390000NoneNoneELIGIBILITYAll rates given in BOQ are inclusive of all taxes like GST etc., Bidder should quote including all taxes etcNone
17215326480000NoneNoneELIGIBILITYTurnover certificate from CA with valid UDIN No. to be furnished along with necessary documents.None
17215326590000NoneNoneELIGIBILITYCorrigendum / modifications / correction, if any, will be published in the e-portal onlyNone
17215326720000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17215327030000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17215327140000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17215327230000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27-07-2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fundNone
17215327340000NoneNoneELIGIBILITYThe Tenderer shall scan Original Workdone certificates / Turnover Statements and any other documents specified by the employer and attach the scanned file to the Bid. The Original Documents shall be produced for physical verification within one week from the date of Technical bid opening.None
17215327440000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so everNone
17215327530000NoneNoneELIGIBILITYThe earnest money deposit will be forfeited if the documents submitted by the tenderer found to be misleading/forged or fake .None
17215327630000NoneNoneELIGIBILITYFinancial values of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2024-25None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneTenderer in his name should have in the last five years i.e., 2019 to 2023-24,, satisfactory completed, at least one similar Building work/ Shed work of value not less than Rs.15.00 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year in the last five years i.e., 2019-20 to 2023-24, the following minimum quantities of work 1.Cement Concrete ( Plain & Reinforced)- 56.92 cum, 2. AC Sheet- 414.56 sqm, 3. Reinforcement / Structural steel work-6.84 TonnePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs. 9.00 Lakhs (Credit lines / Letters of Credit / Certificates from Banks) for meeting the fund requirement etc., (Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNonePWD Registration certificate Class3 and above (Civil) issued by Competent authorityCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTenderer in his name should have in the last five years i.e.2019-20 to 2023-24,achieved in at least two financial years an average annual financial turnover of Rs.30 lakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonePAN CARDFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneGST certificate issued by competent authorityFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Tenderer in his name should have in the last five years i.e.2019-20 to 2023-24,achieved in at least two financial years an average annual financial turnover of Rs.30 lakhsTrueTechnical Bid
PWD Registration Certificate Class-3 and above CivilTrueTechnical Bid
Tenderer in his name should have in the last five years i.e., 2019 to 2023-24,, satisfactory completed, at least one similar Building work/ Shed work of value not less than Rs.15.00 Lakhs as prime contractor.TrueTechnical Bid
Executed in any one year in the last five years i.e., 2019-20 to 2023-24, the following minimum quantities of work 1.Cement Concrete Plain & Reinforced- 56.92 cum, 2. AC Sheet- 414.56 sqm, 3. Reinforcement or Structural steel work-6.84 TonneTrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than Rs. 9.00 Lakhs Credit lines / Letters of Credit / Certificates from Banks for meeting the fund requirement etc., Unconditional Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etcTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone