1721554070000 | 0 | None | None | Buildings | Construction of Proposed 3 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) At Gubbi Town Panchayath Limits Under SBM 2.0 | 2945664.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3571438 | 129734 | None | PWD CSR 2023-24, VOL-1, Page No -8, I No 1.14.1 | KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (I No. 1.14.1 Page No. 8 Vol.1 PWD SR) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 123.97 | 123.97 | 29.406 | False | None | None | False | None | False | 3645.46182 | 0 | 3571439 | 129734 | None | PWD CSR 2023-24, VOL-1, Page -15, I No 2.1.2 | KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (I No. 2.1.2 Page No. 15 Vol.1 PWD SR) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 6884.02 | 6884.02 | 28.9702 | False | None | None | False | None | False | 199431.436204 | 0 | 3571440 | 129734 | None | PWD CSR 2023-24, VOL-1, Page -16, I No 2.3.2 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (I No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) FOOTING ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 7875.79 | 7875.79 | 7.12 | False | None | None | False | None | False | 56075.6248 | 0 | 3571441 | 129734 | None | PWD CSR 2023-24, VOL-1, Page -16, I No 2.3.2 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (I No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) COLUMN ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 7875.79 | 7875.79 | 1.63 | False | None | None | False | None | False | 12837.5377 | 0 | 3571442 | 129734 | None | PWD CSR 2023-24, VOL-1, Page -16, I No 2.3.2 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (I No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) HALL GRADE SLAB ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 7875.79 | 7875.79 | 28.62 | False | None | None | False | None | False | 225405.1098 | 0 | 3571443 | 129734 | None | Appendix I page No.115 | Formwork
As per the Recommendation of Technical working group rates for formwork shall be added on percentage basis to the finished concrete item rate.
For Footing works consider 8% of item concrete rate
FOOTING ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 611.71 | 611.71 | 7.116 | False | None | None | False | None | False | 4352.92836 | 0 | 3571444 | 129734 | None | Appendix I page No.115 | Formwork
As per the Recommendation of Technical working group rates for formwork shall be added on percentage basis to the finished concrete item rate.
For Column works consider 70% of item concrete rate
COLUMN ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 5352.48 | 5352.48 | 1.63 | False | None | None | False | None | False | 8724.5424 | 0 | 3571445 | 129734 | None | Appendix I page No.115 | Formwork
As per the Recommendation of Technical working group rates for formwork shall be added on percentage basis to the finished concrete item rate.
For Slab works consider 8% of item concrete rate HALL GRADE SLAB ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 611.71 | 611.71 | 28.62 | False | None | None | False | None | False | 17507.1402 | 0 | 3571446 | 129734 | None | PWD CSR 2023-24, VOL-1, Page -15, I No 2.2.3 | KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (I No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 7700.77 | 7700.77 | 4.82 | False | None | None | False | None | False | 37117.7114 | 0 | 3571447 | 129734 | None | PWD CSRAppendix I page No.115 | Formwork
As per the Recommendation of Technical working group rates for formwork shall be added on percentage basis to the finished concrete item rate.
For Plinth Beam works consider 50% of item concrete rate PLINTH BEAM
---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 3738.24 | 3738.24 | 4.82 | False | None | None | False | None | False | 18018.3168 | 0 | 3571448 | 129734 | None | PWD SRRB 2023-24, VOL-1, Page -18, I No 2.11 | KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (I No. 2.11 Page No. 18 Vol.1 PWD SR) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Tonne | 108726.03 | 108726.03 | 2.4171 | False | None | None | False | None | False | 262801.687113 | 0 | 3571449 | 129734 | None | PWD CSR 2023-24, VOL-2, Page -9, I No 5.4 | KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (I No. 5.4 Page No. 9 Vol.2 PWD SR) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 7765.19 | 7765.19 | 16.6701 | False | None | None | False | None | False | 129446.493819 | 0 | 3571450 | 129734 | None | PWD SRB 2023-24, VOL-1, Page -07, I No 1.8 | KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (I No. 1.8 Page No. 7 Vol.1 PWD SR) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Cum | 559.32 | 559.32 | 128.79 | False | None | None | False | None | False | 72034.8228 | 0 | 3571451 | 129734 | None | PWD CSR 2023-24, VOL-2, Page No -17, I No 6.33 | KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (I No. 6.33 Page No. 17 Vol.2 PWD SR) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Sqm | 1496.15 | 1496.15 | 91.078 | False | None | None | False | None | False | 136266.3497 | 0 | 3571452 | 129734 | None | PWD CSR 2023-24, VOL-2, Page No -41, I No 8.2.1 | KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(I No. 8.3.1, Page No. 41, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Sqm | 358.54 | 358.54 | 187.56 | False | None | None | False | None | False | 67247.7624 | 0 | 3571453 | 129734 | None | PWD SRRB 2023-24, VOL-2, Page -77, I No 11.2 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (I No. 11.2, Page No. 77, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Kgs | 137.34 | 137.34 | 6130.0 | False | None | None | False | None | False | 841894.2 | 0 | 3571454 | 129734 | None | PWD SRRB 2023-24, VOL-3, Page -26, I No 7.38 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (I No. 7.38, Page No. 26, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Sqm | 690.35 | 690.35 | 518.21 | False | None | None | False | None | False | 357746.2735 | 0 | 3571455 | 129734 | None | PWD SRRB 2023-24, VOL-2, Page -50, I No 8.51 | KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(I No. 8.51, Page No. 50, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Sqm | 121.54 | 121.54 | 187.56 | False | None | None | False | None | False | 22796.0424 | 0 | 3571456 | 129734 | None | PWD SRRB 2023-24, VOL-2, Page -50, I No 8.54.1 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(I No. 8.54.1, Page No. 50, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 88.72 | 88.72 | 91.08 | False | None | None | False | None | False | 8080.6176 | 0 | 3571457 | 129734 | None | PWD SRB 2023-24, VOL-2, Page -42, I No 8.54.1 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(I No. 8.54.1, Page No. 50, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 88.72 | 88.72 | 91.08 | False | None | None | False | None | False | 8080.6176 | 0 | 3571458 | 129734 | None | PWD CSR 2023-24, VOL-2, Page No -76, I No 11.6.1 | KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (I No. 11.6.1, Page No. 76, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Sqm | 3200.14 | 3200.14 | 9.0 | False | None | None | False | None | False | 28801.26 | 0 | 3571459 | 129734 | None | PWD CSR 2021-22, VOL-2, Page No -77, I No 11.8.4 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(I No. 11.8.4, Page No. 77, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 30003.36 | 30003.36 | 1.0 | False | None | None | False | None | False | 30003.36 | 0 | 3571460 | 129734 | None | KUWS&DB 2023-24, VOL-2, Page -87, I No 11.35.1.1 | KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(I No. 11.35.1.1, Page No. 87, Vol.2) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Kg | 549.36 | 549.36 | 240.0 | False | None | None | False | None | False | 131846.4 | 0 | 3571461 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -4, I No 1.1.3 | Supplying heavy gauge PVC conduit pipe 32 dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws..(I No. 1.1.3, Page No.4,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | m | 128.83 | 128.83 | 325.0 | False | None | None | False | None | False | 41869.75 | 0 | 3571462 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -6, I No 2.5.1 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 .(I No. 2.5.1, Page No.6,PWD Electrical SR Vol-06)3C X 4 mm2 ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | m | 209.05 | 209.05 | 325.0 | False | None | None | False | None | False | 67941.25 | 0 | 3571463 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -8, I No 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way (I No. 3.4.5, Page No.8,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 317.21 | 317.21 | 8.0 | False | None | None | False | None | False | 2537.68 | 0 | 3571464 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -8, I No 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (I No. 3.5.5, Page No.8,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 345.17 | 345.17 | 8.0 | False | None | None | False | None | False | 2761.36 | 0 | 3571465 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No 3.13 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.1, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 16A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 471.28 | 471.28 | 4.0 | False | None | None | False | None | False | 1885.12 | 0 | 3571466 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No3.13.2 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.2, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V PLUG 32A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 666.13 | 666.13 | 4.0 | False | None | None | False | None | False | 2664.52 | 0 | 3571467 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No3.13.3 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.3, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 16A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 549.51 | 549.51 | 4.0 | False | None | None | False | None | False | 2198.04 | 0 | 3571468 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No3.13.4 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.4, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V PLUG 32A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 741.22 | 741.22 | 4.0 | False | None | None | False | None | False | 2964.88 | 0 | 3571469 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No3.13.5 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.5, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 16A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 645.34 | 645.34 | 4.0 | False | None | None | False | None | False | 2581.36 | 0 | 3571470 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No3.13.6 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.6, Page No.9,PWD Electrical SR Vol-06) 2pole+earth 250V SOCKET 32A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 810.72 | 810.72 | 4.0 | False | None | None | False | None | False | 3242.88 | 0 | 3571471 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No3.13.7 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.7, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 16A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 770.29 | 770.29 | 4.0 | False | None | None | False | None | False | 3081.16 | 0 | 3571472 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No3.13.8 | Supplying and fixing of metal clad industrial plugs and sockets. ,(I No. 3.13.8, Page No.9,PWD Electrical SR Vol-06) 3pole+earth 440V SOCKET 32A ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 1006.13 | 1006.13 | 4.0 | False | None | None | False | None | False | 4024.52 | 0 | 3571473 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -10, INo3.14.1 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(I No. 3.14.1, Page No.10,PWD Electrical SR Vol-06) 6A SP Switch ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 66.84 | 66.84 | 34.0 | False | None | None | False | None | False | 2272.56 | 0 | 3571474 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -10, INo3.14.3 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(I No. 3.14.3, Page No.10,PWD Electrical SR Vol-06) 6A Three Way 5 Pin Socket ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 85.08 | 85.08 | 7.0 | False | None | None | False | None | False | 595.56 | 0 | 3571475 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -10,INo3.14.10 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(I No. 3.14.10, Page No.10,PWD Electrical SR Vol-06) 16A SP Switch ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 159.21 | 159.21 | 8.0 | False | None | None | False | None | False | 1273.68 | 0 | 3571476 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -10,INo3.14.12 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(I No. 3.14.12, Page No.10,PWD Electrical SR Vol-06) 16A Three Way 5 Pin Socket ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 139.77 | 139.77 | 9.0 | False | None | None | False | None | False | 1257.93 | 0 | 3571477 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -10,INo3.14.14 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(I No. 3.14.14, Page No.10,PWD Electrical SR Vol-06) 32A Bakelite DP ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 281.97 | 281.97 | 8.0 | False | None | None | False | None | False | 2255.76 | 0 | 3571478 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -10,INo3.14.15 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board,(I No. 3.14.15, Page No.10,PWD Electrical SR Vol-06) 16/6A combined plug and socket with control switch ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Nos | 264.95 | 264.95 | 8.0 | False | None | None | False | None | False | 2119.6 | 0 | 3571479 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -17,INo 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.,6-32 A SP(I No. 5.18.1, Page No.17,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 504.39 | 504.39 | 8.0 | False | None | None | False | None | False | 4035.12 | 0 | 3571480 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -9, I No 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws,(I No. 3.8, Page No.9,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Sqm | 0.49 | 0.49 | 4800.0 | False | None | None | False | None | False | 2352.0 | 0 | 3571481 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -16, INo5.15.8 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 50 kA (I No. 5.15.8, Page No.16,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 30505.32 | 30505.32 | 1.0 | False | None | None | False | None | False | 30505.32 | 0 | 3571482 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -16, INo5.17.1 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 4 Way (I No. 5.17.1, Page No.16,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 12553.86 | 12553.86 | 1.0 | False | None | None | False | None | False | 12553.86 | 0 | 3571483 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -21, INo5.46.1 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA 16 - 32 A SP (I No. 5.46.1, Page No.21,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 255.8 | 255.8 | 8.0 | False | None | None | False | None | False | 2046.4 | 0 | 3571484 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -46, INo11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, CCT morethan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire morethan IK08. Power Factor morethan 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencymorethan1301m/w, nominal CRI morethan 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/ Lumileds/Osram make LED Source. (I No. 11.9.1, Page No.46,PWD Electrical SR Vol-06) LED Floodlight 70W ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | Each | 8225.82 | 8225.82 | 6.0 | False | None | None | False | None | False | 49354.92 | 0 | 3571485 | 129734 | None | PWD Electrical 2023-24, VOL-6, Page -542, INo 14.3 | 1.1 kV Class Armoured Aluminium Cable with glands/lugs/ferrules :4C x 70 Sq mm (I No. 14.3, Page No.542,PWD Electrical SR Vol-06) ---- Etc., complete including all lead and lift as per the instruction of the officer in Charge of the work. | m | 658.75 | 658.75 | 26.0 | False | None | None | False | None | False | 17127.5 | 0 |
|