tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721377816000 | 1 | None | None | Buildings | CONSTRUCTION OF THREE ADDITIONAL CLASS ROOM FOR GOVT HIGHER PRIMARY SCHOOL AT CHIKKAHESARUR VILLAGE IN LINGASUGUR TALUKA RAICHUR DISTRICT UNDER KKRDB MICRO 2023-24 OF (SAVING) GRANT FOR THE YEAR 2023-24 RCH23S1923219 RCH23S1923320 RCH23S1923421 | 3372674.64 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3550663 | 128448 | None | PWD DSR 2023-24 V-1 IT.NO 19.9.1 P.No-187 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge. | Cum | 831.6 | 831.6 | 33.95 | False | None | None | False | None | False | 28232.82 | 0 | 3550664 | 128448 | None | PWD DSR 2023-24 V-1 IT.NO 19.57 P.No-193 | Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials to the appropriate disposal area stacking serviceable and unserviceable material separately including cutting reinforcement bars. | Cum | 2466.45 | 2466.45 | 12.57 | False | None | None | False | None | False | 31003.2765 | 0 | 3550665 | 128448 | None | PWD DSR 2023-24 V-1 IT.NO 1.1 P.No-5 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Sqm | 95.55 | 95.55 | 54.18 | False | None | None | False | None | False | 5176.899 | 0 | 3550666 | 128448 | None | PWD DSR 2023-24 V-1 IT.NO 1.12 P.No-8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 99.75 | 99.75 | 105.27 | False | None | None | False | None | False | 10500.6825 | 0 | 3550667 | 128448 | None | PWD DSR 2023-24 V-1 IT.NO 1.5.1P.No-6 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 313.95 | 313.95 | 15.37 | False | None | None | False | None | False | 4825.4115 | 0 | 3550668 | 128448 | None | PWD DSR 2023-24 Vol-I IT No-2.1.2 P.No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 26.3 | False | None | None | False | None | False | 156411.36 | 0 | 3550669 | 128448 | None | PWD DSR 2023-24 Vol-I IT No-2.1.2 P.No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 2.71 | False | None | None | False | None | False | 16116.912 | 0 | 3550670 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-5.1.1 P.No 9 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 22.8 | False | None | None | False | None | False | 134327.34 | 0 | 3550671 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-5.2 P.No 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 15.0 | False | None | None | False | None | False | 104233.5 | 0 | 3550672 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-1.8 P.No 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 160.49 | False | None | None | False | None | False | 79875.873 | 0 | 3550673 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-2.2.3 P.No 15 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 25.92 | False | None | None | False | None | False | 172440.576 | 0 | 3550674 | 128448 | None | PWD DSR 2023-24 Vol-I addendum I P.No 111 | Add Formwork, Centering & Scaffolding charges for Foundation upto Plinth b. All other types 8% For Footing vide, addendum I/ P.No 111 | Cum | 532.22 | 532.22 | 25.92 | False | None | None | False | None | False | 13795.1424 | 0 | 3550675 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-2.2.3 P.No 15 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 1.91 | False | None | None | False | None | False | 12706.848 | 0 | 3550676 | 128448 | None | PWD DSR 2023-24 Vol-I addendum I P.No 111 | Add Formwork, Centering & Scaffolding charges for Columns 70%, addendum I/ P.No 111 | Cum | 4656.96 | 4656.96 | 1.91 | False | None | None | False | None | False | 8894.7936 | 0 | 3550677 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-2.4.3 P.No 16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 6.52 | False | None | None | False | None | False | 43376.256 | 0 | 3550678 | 128448 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Beams & Lintels of Buildings 60% addendum I/ P.No 111 | Cum | 3991.68 | 3991.68 | 6.52 | False | None | None | False | None | False | 26025.7536 | 0 | 3550679 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 5.3 | False | None | None | False | None | False | 36895.95 | 0 | 3550680 | 128448 | None | PWD DSR 2023-24 Vol-I addendum I P.No 111 | Add Formwork, Centering & Scaffolding charges for Columns 70% addendum I/ P.No 111 | Cum | 4873.04 | 4873.04 | 5.3 | False | None | None | False | None | False | 25827.112 | 0 | 3550681 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 13.35 | False | None | None | False | None | False | 92936.025 | 0 | 3550682 | 128448 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Beams & Lintels of Buildings 60% addendum I/ P.No 111 | Cum | 4176.9 | 4176.9 | 13.35 | False | None | None | False | None | False | 55761.615 | 0 | 3550683 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 21.5 | False | None | None | False | None | False | 149672.25 | 0 | 3550684 | 128448 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Roof Slab of Buildings 50% addendum I/ P.No 112 | Cum | 3480.75 | 3480.75 | 21.5 | False | None | None | False | None | False | 74836.125 | 0 | 3550685 | 128448 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.63 | False | None | None | False | None | False | 4385.745 | 0 | 3550686 | 128448 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Chejja, Canopy & Other Architectural projections of minor sections 45% addendum I/ P.No 112 | Cum | 3132.67 | 3132.67 | 0.63 | False | None | None | False | None | False | 1973.5821 | 0 | 3550687 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-6.8 P.No 14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 39.25 | False | None | None | False | None | False | 328422.4125 | 0 | 3550688 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.1.2 P.No 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 228.33 | False | None | None | False | None | False | 57778.9065 | 0 | 3550689 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.8 P.No 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 202.31 | False | None | None | False | None | False | 78809.8605 | 0 | 3550690 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.51 P.No 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 373.04 | False | None | None | False | None | False | 39169.2 | 0 | 3550691 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-11.5.1 P.No 77 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4701.9 | 4701.9 | 7.56 | False | None | None | False | None | False | 35546.364 | 0 | 3550692 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-11.11.1 P.No 79 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the costof other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 155.4 | 155.4 | 380.7 | False | None | None | False | None | False | 59160.78 | 0 | 3550693 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-11.34A P.No 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 340.2 | False | None | None | False | None | False | 60011.28 | 0 | 3550694 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-9.34 P.No 64 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 117.98 | False | None | None | False | None | False | 191393.055 | 0 | 3550695 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-9.30 P.No 64 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 5594.4 | 5594.4 | 66.08 | False | None | None | False | None | False | 369677.952 | 0 | 3550696 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-10.2 P.No 69 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | m | 344.4 | 344.4 | 45.0 | False | None | None | False | None | False | 15498.0 | 0 | 3550697 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.33.3 P.No 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m2 over an under coat of primer applied @ 0.80 ltr/10m2 of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 50.86 | False | None | None | False | None | False | 7423.017 | 0 | 3550698 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-11.26.1 P.No 84 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. | Kg | 144.9 | 144.9 | 235.06 | False | None | None | False | None | False | 34060.194 | 0 | 3550699 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.33.1 P.No 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 165.9 | 165.9 | 238.01 | False | None | None | False | None | False | 39485.859 | 0 | 3550700 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.33.1 P.No 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 165.9 | 165.9 | 176.5 | False | None | None | False | None | False | 29281.35 | 0 | 3550701 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.28 P.No 45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 213.6 | False | None | None | False | None | False | 19960.92 | 0 | 3550702 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-3.3 P.No 23 | Providing Cement mortar 1:3 (1 cement : 3 fine sand) including cost of all materials, labour and usage charges of machinery complete as per the direction of engineer incharge of work. | Sqm | 5691.0 | 5691.0 | 9.45 | False | None | None | False | None | False | 53779.95 | 0 | 3550703 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.70 P.No 52 | Painting (one coats) with black Japan paint of approved brand and manufacture to give an even shade. including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 71.4 | 71.4 | 9.45 | False | None | None | False | None | False | 674.73 | 0 | 3550704 | 128448 | None | PWD DSR 2023-24 V-2 IT.NO 8.19.1 P.No-44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 25.56 | False | None | None | False | None | False | 6843.69 | 0 | 3550705 | 128448 | None | PWD DSR 2023-24 V-1 IT.NO 2.11 P.No-90 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 93929.85 | 93929.85 | 6.66 | False | None | None | False | None | False | 625572.801 | 0 | 3550706 | 128448 | None | PWD DSR 2023-24 Vol-2 IT No-8.49 P.No 49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.2 | 4.2 | 4000.0 | False | None | None | False | None | False | 16800.0 | 0 | 3550707 | 128448 | None | PWD DSR 2023-24 Vol-I IT No-2.1.2 P.No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.21 | False | None | None | False | None | False | 7196.112 | 0 | 3550708 | 128448 | None | PWD DSR 2023-24 V-1 SI No-9 P.No-111 | Add Formwork, Centering & Scaffolding charges for Columns 70% addendum I/ P.No 111 | Cum | 4873.04 | 4873.04 | 1.21 | False | None | None | False | None | False | 5896.3784 | 0 |
| 1721377816000 | 1 | None | None | Buildings | PROVIDING ELECTRIFICATION WORK | 131408.55 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3550709 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 1.2.1 P.No-2 | Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Mtr | 69.3 | 69.3 | 130.0 | False | None | None | False | None | False | 9009.0 | 0 | 3550710 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 1.2.1 P.No-2 | Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Mtr | 81.9 | 81.9 | 130.0 | False | None | None | False | None | False | 10647.0 | 0 | 3550711 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 1.3.1 P.No-2 | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 71.4 | 71.4 | 140.0 | False | None | None | False | None | False | 9996.0 | 0 | 3550712 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 1.3.2 P.No-2 | Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 82.95 | 82.95 | 140.0 | False | None | None | False | None | False | 11613.0 | 0 | 3550713 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 2.2.1 P.No-5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 282.45 | 282.45 | 32.0 | False | None | None | False | None | False | 9038.4 | 0 | 3550714 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 2.2.2 P.No-5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 397.95 | 397.95 | 16.0 | False | None | None | False | None | False | 6367.2 | 0 | 3550715 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 2.2.3 P.No-5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 582.75 | 582.75 | 28.0 | False | None | None | False | None | False | 16317.0 | 0 | 3550716 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 2.3.1 P.No-5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 1.5sqmm. | Mtr | 19.95 | 19.95 | 250.0 | False | None | None | False | None | False | 4987.5 | 0 | 3550717 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 2.3.2 P.No-5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 4 sqmm. | Each | 27.3 | 27.3 | 150.0 | False | None | None | False | None | False | 4095.0 | 0 | 3550718 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.14.6 P.No-10 | 6Amps lamp holder | No | 74.55 | 74.55 | 33.0 | False | None | None | False | None | False | 2460.15 | 0 | 3550719 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.1.1 P.No-8 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 Way | Each | 134.4 | 134.4 | 16.0 | False | None | None | False | None | False | 2150.4 | 0 | 3550720 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.6.1 P.No-9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way switch. | Each | 107.1 | 107.1 | 35.0 | False | None | None | False | None | False | 3748.5 | 0 | 3550721 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.6.8 P.No-9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. | Each | 185.85 | 185.85 | 10.0 | False | None | None | False | None | False | 1858.5 | 0 | 3550722 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.6.11 P.No-9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch. | Each | 163.8 | 163.8 | 35.0 | False | None | None | False | None | False | 5733.0 | 0 | 3550723 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.4.2 P.No-8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket. | Each | 166.95 | 166.95 | 3.0 | False | None | None | False | None | False | 500.85 | 0 | 3550724 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.4.4 P.No-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 4-5Way | Each | 231.0 | 231.0 | 6.0 | False | None | None | False | None | False | 1386.0 | 0 | 3550725 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.4.5 P.No-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 8 Way | Each | 274.05 | 274.05 | 3.0 | False | None | None | False | None | False | 822.15 | 0 | 3550726 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.5.2 P.No-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 10-12 Way | Each | 169.05 | 169.05 | 3.0 | False | None | None | False | None | False | 507.15 | 0 | 3550727 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.5.4 P.No-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module | Each | 245.7 | 245.7 | 6.0 | False | None | None | False | None | False | 1474.2 | 0 | 3550728 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.5.5 P.No-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module | Each | 298.2 | 298.2 | 3.0 | False | None | None | False | None | False | 894.6 | 0 | 3550729 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 3.5.6 P.No-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12 Module | Each | 361.2 | 361.2 | 3.0 | False | None | None | False | None | False | 1083.6 | 0 | 3550730 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 11.13.2 P.No-47 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting. | Each | 282.45 | 282.45 | 20.0 | False | None | None | False | None | False | 5649.0 | 0 | 3550731 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 12.12.1 P.No-48 | Supplying and fixing/replacing of fluorescent tube. 18 to 40W | Each | 99.75 | 99.75 | 9.0 | False | None | None | False | None | False | 897.75 | 0 | 3550732 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 6.3.2 P.No-30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS- 374-1979 and with double ball bearing system. 56" Sweep (1400mm) Regular model | Each | 3182.55 | 3182.55 | 6.0 | False | None | None | False | None | False | 19095.3 | 0 | 3550733 | 128449 | None | Electrical DSR 2023-24 V-6 It.no 13.10 P.No-57 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 179.55 | 179.55 | 6.0 | False | None | None | False | None | False | 1077.3 | 0 |
| 1721377816000 | 1 | None | None | Buildings | CONSTRUCTION OF THREE ADDITIONAL CLASS ROOM FOR GOVT HIGHER PRIMARY SCHOOL AT CHIKKAHESARUR VILLAGE IN LINGASUGUR TALUKA RAICHUR DISTRICT UNDER KKRDB MICRO 2023-24 OF (SAVING) GRANT FOR THE YEAR 2023-24 RCH23S1923219 RCH23S1923320 RCH23S1923421(Reserved for ST Category) | 3504083.21 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3550734 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 1.2.1 P.No-2 | Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Mtr | 69.3 | 69.3 | 130.0 | False | None | None | False | None | False | 9009.0 | 0 | 3550735 | 128450 | None | PWD DSR 2023-24 V-1 IT.NO 19.9.1 P.No-187 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge. | Cum | 831.6 | 831.6 | 33.95 | False | None | None | False | None | False | 28232.82 | 0 | 3550736 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 1.2.1 P.No-2 | Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | Mtr | 81.9 | 81.9 | 130.0 | False | None | None | False | None | False | 10647.0 | 0 | 3550737 | 128450 | None | PWD DSR 2023-24 V-1 IT.NO 19.57 P.No-193 | Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials to the appropriate disposal area stacking serviceable and unserviceable material separately including cutting reinforcement bars. | Cum | 2466.45 | 2466.45 | 12.57 | False | None | None | False | None | False | 31003.2765 | 0 | 3550738 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 1.3.1 P.No-2 | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 71.4 | 71.4 | 140.0 | False | None | None | False | None | False | 9996.0 | 0 | 3550739 | 128450 | None | PWD DSR 2023-24 V-1 IT.NO 1.1 P.No-5 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Sqm | 95.55 | 95.55 | 54.18 | False | None | None | False | None | False | 5176.899 | 0 | 3550740 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 1.3.2 P.No-2 | Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 82.95 | 82.95 | 140.0 | False | None | None | False | None | False | 11613.0 | 0 | 3550741 | 128450 | None | PWD DSR 2023-24 V-1 IT.NO 1.12 P.No-8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 99.75 | 99.75 | 105.27 | False | None | None | False | None | False | 10500.6825 | 0 | 3550742 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 2.2.1 P.No-5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 282.45 | 282.45 | 32.0 | False | None | None | False | None | False | 9038.4 | 0 | 3550743 | 128450 | None | PWD DSR 2023-24 V-1 IT.NO 1.5.1P.No-6 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 313.95 | 313.95 | 15.37 | False | None | None | False | None | False | 4825.4115 | 0 | 3550744 | 128450 | None | PWD DSR 2023-24 Vol-I IT No-2.1.2 P.No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 26.3 | False | None | None | False | None | False | 156411.36 | 0 | 3550745 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 2.2.2 P.No-5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 397.95 | 397.95 | 16.0 | False | None | None | False | None | False | 6367.2 | 0 | 3550746 | 128450 | None | PWD DSR 2023-24 Vol-I IT No-2.1.2 P.No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 2.71 | False | None | None | False | None | False | 16116.912 | 0 | 3550747 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 2.2.3 P.No-5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 582.75 | 582.75 | 28.0 | False | None | None | False | None | False | 16317.0 | 0 | 3550748 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 2.3.1 P.No-5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 1.5sqmm. | Mtr | 19.95 | 19.95 | 250.0 | False | None | None | False | None | False | 4987.5 | 0 | 3550749 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-5.1.1 P.No 9 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 22.8 | False | None | None | False | None | False | 134327.34 | 0 | 3550750 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 2.3.2 P.No-5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 4 sqmm. | Each | 27.3 | 27.3 | 150.0 | False | None | None | False | None | False | 4095.0 | 0 | 3550751 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-5.2 P.No 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 15.0 | False | None | None | False | None | False | 104233.5 | 0 | 3550752 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-1.8 P.No 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 160.49 | False | None | None | False | None | False | 79875.873 | 0 | 3550753 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.14.6 P.No-10 | 6Amps lamp holder | No | 74.55 | 74.55 | 33.0 | False | None | None | False | None | False | 2460.15 | 0 | 3550754 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-2.2.3 P.No 15 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 25.92 | False | None | None | False | None | False | 172440.576 | 0 | 3550755 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.1.1 P.No-8 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 Way | Each | 134.4 | 134.4 | 16.0 | False | None | None | False | None | False | 2150.4 | 0 | 3550756 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.6.1 P.No-9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way switch. | Each | 107.1 | 107.1 | 35.0 | False | None | None | False | None | False | 3748.5 | 0 | 3550757 | 128450 | None | PWD DSR 2023-24 Vol-I addendum I P.No 111 | Add Formwork, Centering & Scaffolding charges for Foundation upto Plinth b. All other types 8% For Footing vide, addendum I/ P.No 111 | Cum | 532.22 | 532.22 | 25.92 | False | None | None | False | None | False | 13795.1424 | 0 | 3550758 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.6.8 P.No-9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. | Each | 185.85 | 185.85 | 10.0 | False | None | None | False | None | False | 1858.5 | 0 | 3550759 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-2.2.3 P.No 15 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 1.91 | False | None | None | False | None | False | 12706.848 | 0 | 3550760 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.6.11 P.No-9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch. | Each | 163.8 | 163.8 | 35.0 | False | None | None | False | None | False | 5733.0 | 0 | 3550761 | 128450 | None | PWD DSR 2023-24 Vol-I addendum I P.No 111 | Add Formwork, Centering & Scaffolding charges for Columns 70%, addendum I/ P.No 111 | Cum | 4656.96 | 4656.96 | 1.91 | False | None | None | False | None | False | 8894.7936 | 0 | 3550762 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-2.4.3 P.No 16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 6.52 | False | None | None | False | None | False | 43376.256 | 0 | 3550763 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.4.2 P.No-8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socket. | Each | 166.95 | 166.95 | 3.0 | False | None | None | False | None | False | 500.85 | 0 | 3550764 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.4.4 P.No-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 4-5Way | Each | 231.0 | 231.0 | 6.0 | False | None | None | False | None | False | 1386.0 | 0 | 3550765 | 128450 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Beams & Lintels of Buildings 60% addendum I/ P.No 111 | Cum | 3991.68 | 3991.68 | 6.52 | False | None | None | False | None | False | 26025.7536 | 0 | 3550766 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.4.5 P.No-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 8 Way | Each | 274.05 | 274.05 | 3.0 | False | None | None | False | None | False | 822.15 | 0 | 3550767 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 5.3 | False | None | None | False | None | False | 36895.95 | 0 | 3550768 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.5.2 P.No-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 10-12 Way | Each | 169.05 | 169.05 | 3.0 | False | None | None | False | None | False | 507.15 | 0 | 3550769 | 128450 | None | PWD DSR 2023-24 Vol-I addendum I P.No 111 | Add Formwork, Centering & Scaffolding charges for Columns 70% addendum I/ P.No 111 | Cum | 4873.04 | 4873.04 | 5.3 | False | None | None | False | None | False | 25827.112 | 0 | 3550770 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.5.4 P.No-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module | Each | 245.7 | 245.7 | 6.0 | False | None | None | False | None | False | 1474.2 | 0 | 3550771 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 13.35 | False | None | None | False | None | False | 92936.025 | 0 | 3550772 | 128450 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Beams & Lintels of Buildings 60% addendum I/ P.No 111 | Cum | 4176.9 | 4176.9 | 13.35 | False | None | None | False | None | False | 55761.615 | 0 | 3550773 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.5.5 P.No-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module | Each | 298.2 | 298.2 | 3.0 | False | None | None | False | None | False | 894.6 | 0 | 3550774 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 21.5 | False | None | None | False | None | False | 149672.25 | 0 | 3550775 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 3.5.6 P.No-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12 Module | Each | 361.2 | 361.2 | 3.0 | False | None | None | False | None | False | 1083.6 | 0 | 3550776 | 128450 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Roof Slab of Buildings 50% addendum I/ P.No 112 | Cum | 3480.75 | 3480.75 | 21.5 | False | None | None | False | None | False | 74836.125 | 0 | 3550777 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 11.13.2 P.No-47 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting. | Each | 282.45 | 282.45 | 20.0 | False | None | None | False | None | False | 5649.0 | 0 | 3550778 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 12.12.1 P.No-48 | Supplying and fixing/replacing of fluorescent tube. 18 to 40W | Each | 99.75 | 99.75 | 9.0 | False | None | None | False | None | False | 897.75 | 0 | 3550779 | 128450 | None | PWD DSR 2023-24 Vol-1 IT No-2.5.1 P.No 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.63 | False | None | None | False | None | False | 4385.745 | 0 | 3550780 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 6.3.2 P.No-30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS- 374-1979 and with double ball bearing system. 56" Sweep (1400mm) Regular model | Each | 3182.55 | 3182.55 | 6.0 | False | None | None | False | None | False | 19095.3 | 0 | 3550781 | 128450 | None | PWD DSR 2023-24 Vol-I addendum I P.No 112 | Add Formwork, Centering & Scaffolding charges for Chejja, Canopy & Other Architectural projections of minor sections 45% addendum I/ P.No 112 | Cum | 3132.67 | 3132.67 | 0.63 | False | None | None | False | None | False | 1973.5821 | 0 | 3550782 | 128450 | None | Electrical DSR 2023-24 V-6 It.no 13.10 P.No-57 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 179.55 | 179.55 | 6.0 | False | None | None | False | None | False | 1077.3 | 0 | 3550783 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-6.8 P.No 14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 39.25 | False | None | None | False | None | False | 328422.4125 | 0 | 3550784 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.1.2 P.No 41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 228.33 | False | None | None | False | None | False | 57778.9065 | 0 | 3550785 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.8 P.No 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 202.31 | False | None | None | False | None | False | 78809.8605 | 0 | 3550786 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.51 P.No 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 373.04 | False | None | None | False | None | False | 39169.2 | 0 | 3550787 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-11.5.1 P.No 77 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4701.9 | 4701.9 | 7.56 | False | None | None | False | None | False | 35546.364 | 0 | 3550788 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-11.11.1 P.No 79 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the costof other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 155.4 | 155.4 | 380.7 | False | None | None | False | None | False | 59160.78 | 0 | 3550789 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-11.34A P.No 86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 340.2 | False | None | None | False | None | False | 60011.28 | 0 | 3550790 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-9.34 P.No 64 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1622.25 | 1622.25 | 117.98 | False | None | None | False | None | False | 191393.055 | 0 | 3550791 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-9.30 P.No 64 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. | Sqm | 5594.4 | 5594.4 | 66.08 | False | None | None | False | None | False | 369677.952 | 0 | 3550792 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-10.2 P.No 69 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | m | 344.4 | 344.4 | 45.0 | False | None | None | False | None | False | 15498.0 | 0 | 3550793 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.33.3 P.No 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m2 over an under coat of primer applied @ 0.80 ltr/10m2 of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 50.86 | False | None | None | False | None | False | 7423.017 | 0 | 3550794 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-11.26.1 P.No 84 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. | Kg | 144.9 | 144.9 | 235.06 | False | None | None | False | None | False | 34060.194 | 0 | 3550795 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.33.1 P.No 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 165.9 | 165.9 | 238.01 | False | None | None | False | None | False | 39485.859 | 0 | 3550796 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.33.1 P.No 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m over and including one coat of Special primer applied @ 0.75 ltr /10 m with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. | Sqm | 165.9 | 165.9 | 176.5 | False | None | None | False | None | False | 29281.35 | 0 | 3550797 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.28 P.No 45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 213.6 | False | None | None | False | None | False | 19960.92 | 0 | 3550798 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-3.3 P.No 23 | Providing Cement mortar 1:3 (1 cement : 3 fine sand) including cost of all materials, labour and usage charges of machinery complete as per the direction of engineer incharge of work. | Sqm | 5691.0 | 5691.0 | 9.45 | False | None | None | False | None | False | 53779.95 | 0 | 3550799 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.70 P.No 52 | Painting (one coats) with black Japan paint of approved brand and manufacture to give an even shade. including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 71.4 | 71.4 | 9.45 | False | None | None | False | None | False | 674.73 | 0 | 3550800 | 128450 | None | PWD DSR 2023-24 V-2 IT.NO 8.19.1 P.No-44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 25.56 | False | None | None | False | None | False | 6843.69 | 0 | 3550801 | 128450 | None | PWD DSR 2023-24 V-1 IT.NO 2.11 P.No-90 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 93929.85 | 93929.85 | 6.66 | False | None | None | False | None | False | 625572.801 | 0 | 3550802 | 128450 | None | PWD DSR 2023-24 Vol-2 IT No-8.49 P.No 49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.2 | 4.2 | 4000.0 | False | None | None | False | None | False | 16800.0 | 0 | 3550803 | 128450 | None | PWD DSR 2023-24 Vol-I IT No-2.1.2 P.No 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.21 | False | None | None | False | None | False | 7196.112 | 0 | 3550804 | 128450 | None | PWD DSR 2023-24 V-1 SI No-9 P.No-111 | Add Formwork, Centering & Scaffolding charges for Columns 70% addendum I/ P.No 111 | Cum | 4873.04 | 4873.04 | 1.21 | False | None | None | False | None | False | 5896.3784 | 0 |
|
|
---|