tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719314985000 | 1 | None | None | Roads | CC Road and Drain | 5296324.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3348667 | 117764 | None | PWD Common Volume 3 SR S.No.3.7 P.No.17 for 2023-2 | Loosening leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
| Cum | 110.25 | 110.25 | 116.93 | False | None | None | False | None | False | 12891.5325 | 0 | 3348668 | 117764 | None | PWD CSR Volume 3 S.No.2.19 202 P.No.12 for 2023- | Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical meansusing pneumatic tools, breaking to pieces not exceeding 0.02 min volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately | Cum | 591.15 | 591.15 | 259.81 | False | None | None | False | None | False | 153586.6815 | 0 | 3348669 | 117764 | None | PWD Common SR Volume 3 S.No.3.6 P.No.17 for 2023-2 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
| Cum | 517.65 | 517.65 | 143.93 | False | None | None | False | None | False | 74505.3645 | 0 | 3348670 | 117764 | None | PWD Common SR Volume 3 S.No.4.1 .A.(v) P.No.24 for | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading -V Material
| Cum | 2611.35 | 2611.35 | 77.95 | False | None | None | False | None | False | 203554.7325 | 0 | 3348671 | 117764 | None | PWD Common Volume 3 SR S.No.4.17 P.No.26 for 2023- | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density
| Cum | 2686.95 | 2686.95 | 58.46 | False | None | None | False | None | False | 157079.097 | 0 | 3348672 | 117764 | None | PWD Common SR Volume 3 S.No.16.27 P.No.148 for 202 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design,over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle,screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges,cost and conveyance of all materials, labour, equipments etc.complete. as per the directions of the Engineer-in-charge of the work
| Cum | 6692.7 | 6692.7 | 116.93 | False | None | None | False | None | False | 782577.411 | 0 | 3348673 | 117764 | None | PWD Common SR Volume 1 S.No.1.14.1 P.No.8 for 202 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete work. In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 453.69 | False | None | None | False | None | False | 48590.199 | 0 | 3348674 | 117764 | None | PWD Common SR Volume 1 S.No.2.1.2 P.No.15 for 202 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications
| Cum | 5947.2 | 5947.2 | 72.56 | False | None | None | False | None | False | 431528.832 | 0 | 3348675 | 117764 | None | PWD Common SR Volume 1 S.No.2.4.2 P.No.16 for 202 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6639.15 | 6639.15 | 217.2 | False | None | None | False | None | False | 1442023.38 | 0 | 3348676 | 117764 | None | PWD Common SR Volume 1 S.No.2.11 (h) P.No.111 for | Centering and shuttering for Cement Concrete Drain Walls 35 Percent
| Cum | 2323.7 | 2323.7 | 217.2 | False | None | None | False | None | False | 504707.64 | 0 | 3348677 | 117764 | None | PWD Common SR Volume 1 S.No.2.11 (h) P.No.18 for | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification .All other type of structures
| Tonne | 82961.55 | 82961.55 | 12.48 | False | None | None | False | None | False | 1035360.144 | 0 | 3348678 | 117764 | None | PWD Common SR Volume 2 S.No. 17.12 P.No.176 for 20 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 974.4 | 974.4 | 320.0 | False | None | None | False | None | False | 311808.0 | 0 | 3348679 | 117764 | None | PWD Common SR Volume 5 S.No. 16.28.1 P.No.198 for | Repairs to Machinehole for different depths including removal of debris, levelling the brick masonry, construction of brick masonry upto Ground level, providing CC coping alround the MH cover, plastering both inside and outside to the brick masonry and fixing of manhole frame and cover, curing, refilling with appurtenances complete.16.28.1 Upto 0.30m depth | No | 8577.45 | 8577.45 | 15.0 | False | None | None | False | None | False | 128661.75 | 0 | 3348680 | 117764 | None | PWD Common SR Volume 3 S.No. 8.55 P.No.78 for 2023 | Providing and fixing board displaying information, such as 'Name of work, ender cost, Name of Contractor, Work completion and liability period etc',having rectangular shape of 1.20m x 0.90m size made out 18 gauge(1.25mm) thick mild steel sheet painted with one coat of Zinc hromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved olour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. Asdirected by Engineer in Charge & MoRTH specification 804
| No | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 |
| 1719314985000 | 1 | None | None | Roads | Electrical Work | 3611041.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3348681 | 117765 | None | Gescom rates | 200105-RCC Pole-9.0M Long,145 kg WL,Erection of RCC/PSC
poles 9 to 10 mtr long but
in a pit of 1.8 mtr depth | No | 9954.81 | 9954.81 | 18.0 | False | None | None | False | None | False | 179186.58 | 0 | 3348682 | 117765 | None | Gescom Rates | Ordinary Soil | No | 660.45 | 660.45 | 18.0 | False | None | None | False | None | False | 11888.1 | 0 | 3348683 | 117765 | None | Gescom rates | 27901205-11 kV Horizontal cross arm wit,Fixing of V-Shape/ Horizontal cross arm including single top support Braces and Insulators fixing | No | 1070.24 | 1070.24 | 18.0 | False | None | None | False | None | False | 19264.32 | 0 | 3348684 | 117765 | None | Gescom rates | 283008-11kV, 5KN Composite/Polymeric, | No | 253.99 | 253.99 | 54.0 | False | None | None | False | None | False | 13715.46 | 0 | 3348685 | 117765 | None | Gescom rates | 283320-Silcon rubber composite insula | No | 230.45 | 230.45 | 6.0 | False | None | None | False | None | False | 1382.7 | 0 | 3348686 | 117765 | None | Gescom rates | 284108-Rabbit ACSR Conductor , For Rabbit ACSR | Mtr | 77.09 | 77.09 | 2700.0 | False | None | None | False | None | False | 208143.0 | 0 | 3348687 | 117765 | None | Gescom rates | 278811-11kv Danger board, Fixing Danger Board | No | 269.85 | 269.85 | 1.0 | False | None | None | False | None | False | 269.85 | 0 | 3348688 | 117765 | None | Gescom Rates | 278911- Barbed wire (10 mts.),G.I. Barbed Wire (12 mtrs/1kg) | Each | 154.37 | 154.37 | 2.0 | False | None | None | False | None | False | 308.74 | 0 | 3348689 | 117765 | None | Gescom rates | 27911104-9 Mtr RCC DP Transformer Strct, | Set | 46578.96 | 46578.96 | 1.0 | False | None | None | False | None | False | 46578.96 | 0 | 3348690 | 117765 | None | Gescom rates | Ordinary Soil(labour) | No | 660.45 | 660.45 | 2.0 | False | None | None | False | None | False | 1320.9 | 0 | 3348691 | 117765 | None | Gescom rates | 279149-11kV G.O.S.Mounting H-Frame set,Errection of H Frame | Set | 5706.45 | 5706.45 | 1.0 | False | None | None | False | None | False | 5706.45 | 0 | 3348692 | 117765 | None | Gescom rates | 2798001-Fish plate with necessary clam | No | 327.09 | 327.09 | 2.0 | False | None | None | False | None | False | 654.18 | 0 | 3348693 | 117765 | None | Gescom rates | Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit /Distribution Box via metering box. | No | 996.45 | 996.45 | 1.0 | False | None | None | False | None | False | 996.45 | 0 | 3348694 | 117765 | None | Gescom rates | 281008-8 SWG G.I.Wire | Kg | 92.97 | 92.97 | 5.0 | False | None | None | False | None | False | 464.85 | 0 | 3348695 | 117765 | None | Gescom rates | 281110-7/10 SWG Guy Wire | Kg | 95.68 | 95.68 | 10.0 | False | None | None | False | None | False | 956.8 | 0 | 3348696 | 117765 | None | Gescom rates | 2811101-Guy with Complete set, Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised
steel wire with turn buckle
and anchoring
arrangement as per
approved drawing.
(Excluding excavation of
PIT) | Set | 1728.93 | 1728.93 | 4.0 | False | None | None | False | None | False | 6915.72 | 0 | 3348697 | 117765 | None | Gescom codes | Ordinary Soil(labour) | No | 343.35 | 343.35 | 1.0 | False | None | None | False | None | False | 343.35 | 0 | 3348698 | 117765 | None | Gescom rates | 2811103-Earthing Materials Type for gr, Ordinary Soil | No | 2939.18 | 2939.18 | 3.0 | False | None | None | False | None | False | 8817.54 | 0 | 3348699 | 117765 | None | Gescom rates | Providing GI Pipe Earthing for lightning
arresters Transformer Neutral and Transformer Metal parts (Excluding
digging of pits)(labour) | No | 199.5 | 199.5 | 3.0 | False | None | None | False | None | False | 598.5 | 0 | 3348700 | 117765 | None | Gescom rates | 283008-11kV, 5KN Composite/Polymeric | No | 253.99 | 253.99 | 3.0 | False | None | None | False | None | False | 761.97 | 0 | 3348701 | 117765 | None | Gescom rates | 283320-Silcon rubber composite insula | No | 230.45 | 230.45 | 3.0 | False | None | None | False | None | False | 691.35 | 0 | 3348702 | 117765 | None | Gescom rates | 284503-LT Spacer for TC Wiring | No | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3348703 | 117765 | None | Gescom rates | 285557-120Sq.mm (P.G. Clamps Rabbit | No | 338.25 | 338.25 | 4.0 | False | None | None | False | None | False | 1353.0 | 0 | 3348704 | 117765 | None | Gescom rates | 288532-120 Sq.mm Copper terminals (Lo | No | 173.46 | 173.46 | 12.0 | False | None | None | False | None | False | 2081.52 | 0 | 3348705 | 117765 | None | Gescom rates | 301107-L.T.Protection kit,Fixing of LT Protection Kit | No | 2880.3 | 2880.3 | 2.0 | False | None | None | False | None | False | 5760.6 | 0 | 3348706 | 117765 | None | Gescom rates | 301230-L.T.Distribution Box for 100,Fixing LT Distribution box for 100/ 250 / 500 KVA
DTCs (Excluding wiring)
| No | 28512.2 | 28512.2 | 1.0 | False | None | None | False | None | False | 28512.2 | 0 | 3348707 | 117765 | None | Gescom rates | 302011-11 kV D.O.L.O Cutouts Convent,Fixing DOLO cutouts /
Horn Gap Fuses including
fixing of cross arms and
wiring | Set of 3 Nos | 7527.98 | 7527.98 | 1.0 | False | None | None | False | None | False | 7527.98 | 0 | 3348708 | 117765 | None | Gescom rates | 303200-L.A. 9kV, 5kA, Metal Oxide, | No | 1139.88 | 1139.88 | 3.0 | False | None | None | False | None | False | 3419.64 | 0 | 3348709 | 117765 | None | Gescom rates | Fixing of 3 Nos lightning
arrestors including wiring(Labour) | No | 124.95 | 124.95 | 1.0 | False | None | None | False | None | False | 124.95 | 0 | 3348710 | 117765 | None | Gescom rates | 304212-11kV G.O.S 200A Single break,Fixing of GOS including
wiring (11kV SB 200A) | Set | 12867.75 | 12867.75 | 1.0 | False | None | None | False | None | False | 12867.75 | 0 | 3348711 | 117765 | None | Gescom rates | 321467-100 Kva,Aluminium wdg,star 2(5,Erection of 100 kVA
Transformer on
Transformer structure. | No | 276668.03 | 276668.03 | 1.0 | False | None | None | False | None | False | 276668.03 | 0 | 3348712 | 117765 | None | Gescom rates | 357510-L.T. Electronic Tri-Vector Met,LT Electroic Tri-Vector
Meter 5A, Class-0.5/1.0
Accuracy | No | 5045.54 | 5045.54 | 1.0 | False | None | None | False | None | False | 5045.54 | 0 | 3348713 | 117765 | None | Gescom rates | 358066-With CT ratio150/5 for 100 kVA,358066-With CT ratio150/5 for 100 kVA | MT | 7995.08 | 7995.08 | 1.0 | False | None | None | False | None | False | 7995.08 | 0 | 3348714 | 117765 | None | Gescom rates | 200006-PSC Pole-9.0M Long,200 kg WL,Erection of RCC/PSC
poles 9 to 10 mtr long but
in a pit of 1.8 mtr depth | No | 6371.21 | 6371.21 | 26.0 | False | None | None | False | None | False | 165651.46 | 0 | 3348715 | 117765 | None | Gescom rates | Ordinary Soil (labour) | No | 660.45 | 660.45 | 26.0 | False | None | None | False | None | False | 17171.7 | 0 | 3348716 | 117765 | None | Gescom rates | 200105-RCC Pole-9.0M Long,145 kg WL,Erection of RCC/PSC
poles 9 to 10 mtr long but
in a pit of 1.8 mtr depth | No | 9935.81 | 9935.81 | 5.0 | False | None | None | False | None | False | 49679.05 | 0 | 3348717 | 117765 | None | Gescom rates | Ordinary Soil(labour) | No | 660.45 | 660.45 | 5.0 | False | None | None | False | None | False | 3302.25 | 0 | 3348718 | 117765 | None | Gescom rates | 27901203-4 pin cross arm with pole clam,Fixing of 4 Pin cross arm
with insulator and Braces
fixing | No | 692.1 | 692.1 | 7.0 | False | None | None | False | None | False | 4844.7 | 0 | 3348719 | 117765 | None | Gescom rates | 283003-1.1kV Pin Insulator (Shell on | No | 38.4 | 38.4 | 13.0 | False | None | None | False | None | False | 499.2 | 0 | 3348720 | 117765 | None | Gescom rates | 283053-1.1kV Pin Insulator (G.I Pin | No | 43.36 | 43.36 | 13.0 | False | None | None | False | None | False | 563.68 | 0 | 3348721 | 117765 | None | Gescom rates | 284105-Weasel ACSR Conductor,Stringing of conductor wren, squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. | Mtr | 47.12 | 47.12 | 400.0 | False | None | None | False | None | False | 18848.0 | 0 | 3348722 | 117765 | None | Gescom rates | 284819-3x95+1x70+1x16 street light (I,Stringing of 1.1kV grade aerial bunched 3 core cable of XLPE insulation standard aluminum conductor, standard around a weather resistant black XLPE insulated AAA messenger wire 1. (3x95) (for Phase conductor) + (1x70) (insulated messenger
neutral) + (1x16) | Km | 646943.2 | 646943.2 | 3.5 | False | None | None | False | None | False | 2264301.2 | 0 | 3348723 | 117765 | None | Gescom rates | 284820-Single phase Distribution box | No | 2974.84 | 2974.84 | 20.0 | False | None | None | False | None | False | 59496.8 | 0 | 3348724 | 117765 | None | Gescom rates | 284822-Piercing connector suitable fo, Installation of Insulation piercing connector for main to service line Main 16-95sqmm, Tap 4-35sqmm(P2X95), | No | 462.74 | 462.74 | 150.0 | False | None | None | False | None | False | 69411.0 | 0 | 3348725 | 117765 | None | Gescom rates | 284825-Dead end clamp / Anchor clamp | No | 188.33 | 188.33 | 20.0 | False | None | None | False | None | False | 3766.6 | 0 | 3348726 | 117765 | None | Gescom rates | 284826-Suspension clamp assembly 25t,Erection of Suspension Clamp - 25 to 95 sqmm insulated messenger with bracket | No | 521.85 | 521.85 | 50.0 | False | None | None | False | None | False | 26092.5 | 0 | 3348727 | 117765 | None | Gescom rates | 900369-Group C A) 24 Watts | Each | 5250.0 | 5250.0 | 10.0 | False | None | None | False | None | False | 52500.0 | 0 | 3348728 | 117765 | None | Gescom rates | Installation of Insulation piercing connector for main to street light Main : 16-95sqmm, Tap : 1.5- 10sqmm(EP95)
| No | 94.5 | 94.5 | 150.0 | False | None | None | False | None | False | 14175.0 | 0 |
| 1719316189000 | 1 | None | None | Roads | Construction of CC Road ,CC drain ,Erecting electrical poles and street lights at Janata colony ward no 25,Sindhanur CMC limit sindhanur taluk (Sindhanur Constituency) In Sindhanur taluk Raichur District. Under KKRDB Micro Fund (Non-Social) for the year 2023-24 (RCH2320241611) | 8907366.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3352215 | 117881 | None | Gescom rates | 200105-RCC Pole-9.0M Long,145 kg WL,Erection of RCC/PSC
poles 9 to 10 mtr long but
in a pit of 1.8 mtr depth | No | 9954.81 | 9954.81 | 18.0 | False | None | None | False | None | False | 179186.58 | 0 | 3352263 | 117881 | None | PWD Common Volume 3 SR S.No.3.7 P.No.17 for 2023-2 | Loosening leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
| Cum | 110.25 | 110.25 | 116.93 | False | None | None | False | None | False | 12891.5325 | 0 | 3352264 | 117881 | None | PWD CSR Volume 3 S.No.2.19 202 P.No.12 for 2023- | Dismantling of Cement Concrete Pavement Dismantling of cement concrete pavement by mechanical meansusing pneumatic tools, breaking to pieces not exceeding 0.02 min volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately | Cum | 591.15 | 591.15 | 259.81 | False | None | None | False | None | False | 153586.6815 | 0 | 3352216 | 117881 | None | Gescom Rates | Ordinary Soil | No | 660.45 | 660.45 | 18.0 | False | None | None | False | None | False | 11888.1 | 0 | 3352265 | 117881 | None | PWD Common SR Volume 3 S.No.3.6 P.No.17 for 2023-2 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
| Cum | 517.65 | 517.65 | 143.93 | False | None | None | False | None | False | 74505.3645 | 0 | 3352217 | 117881 | None | Gescom rates | 27901205-11 kV Horizontal cross arm wit,Fixing of V-Shape/ Horizontal cross arm including single top support Braces and Insulators fixing | No | 1070.24 | 1070.24 | 18.0 | False | None | None | False | None | False | 19264.32 | 0 | 3352218 | 117881 | None | Gescom rates | 283008-11kV, 5KN Composite/Polymeric, | No | 253.99 | 253.99 | 54.0 | False | None | None | False | None | False | 13715.46 | 0 | 3352266 | 117881 | None | PWD Common SR Volume 3 S.No.4.1 .A.(v) P.No.24 for | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 Grading -V Material
| Cum | 2611.35 | 2611.35 | 77.95 | False | None | None | False | None | False | 203554.7325 | 0 | 3352219 | 117881 | None | Gescom rates | 283320-Silcon rubber composite insula | No | 230.45 | 230.45 | 6.0 | False | None | None | False | None | False | 1382.7 | 0 | 3352267 | 117881 | None | PWD Common Volume 3 SR S.No.4.17 P.No.26 for 2023- | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density
| Cum | 2686.95 | 2686.95 | 58.46 | False | None | None | False | None | False | 157079.097 | 0 | 3352268 | 117881 | None | PWD Common SR Volume 3 S.No.16.27 P.No.148 for 202 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design,over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle,screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges,cost and conveyance of all materials, labour, equipments etc.complete. as per the directions of the Engineer-in-charge of the work
| Cum | 6692.7 | 6692.7 | 116.93 | False | None | None | False | None | False | 782577.411 | 0 | 3352220 | 117881 | None | Gescom rates | 284108-Rabbit ACSR Conductor , For Rabbit ACSR | Mtr | 77.09 | 77.09 | 2700.0 | False | None | None | False | None | False | 208143.0 | 0 | 3352269 | 117881 | None | PWD Common SR Volume 1 S.No.1.14.1 P.No.8 for 202 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete work. In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 453.69 | False | None | None | False | None | False | 48590.199 | 0 | 3352221 | 117881 | None | Gescom rates | 278811-11kv Danger board, Fixing Danger Board | No | 269.85 | 269.85 | 1.0 | False | None | None | False | None | False | 269.85 | 0 | 3352222 | 117881 | None | Gescom Rates | 278911- Barbed wire (10 mts.),G.I. Barbed Wire (12 mtrs/1kg) | Each | 154.37 | 154.37 | 2.0 | False | None | None | False | None | False | 308.74 | 0 | 3352270 | 117881 | None | PWD Common SR Volume 1 S.No.2.1.2 P.No.15 for 202 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications
| Cum | 5947.2 | 5947.2 | 72.56 | False | None | None | False | None | False | 431528.832 | 0 | 3352223 | 117881 | None | Gescom rates | 27911104-9 Mtr RCC DP Transformer Strct, | Set | 46578.96 | 46578.96 | 1.0 | False | None | None | False | None | False | 46578.96 | 0 | 3352271 | 117881 | None | PWD Common SR Volume 1 S.No.2.4.2 P.No.16 for 202 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6639.15 | 6639.15 | 217.2 | False | None | None | False | None | False | 1442023.38 | 0 | 3352224 | 117881 | None | Gescom rates | Ordinary Soil(labour) | No | 660.45 | 660.45 | 2.0 | False | None | None | False | None | False | 1320.9 | 0 | 3352272 | 117881 | None | PWD Common SR Volume 1 S.No.2.11 (h) P.No.111 for | Centering and shuttering for Cement Concrete Drain Walls 35 Percent
| Cum | 2323.7 | 2323.7 | 217.2 | False | None | None | False | None | False | 504707.64 | 0 | 3352225 | 117881 | None | Gescom rates | 279149-11kV G.O.S.Mounting H-Frame set,Errection of H Frame | Set | 5706.45 | 5706.45 | 1.0 | False | None | None | False | None | False | 5706.45 | 0 | 3352273 | 117881 | None | PWD Common SR Volume 1 S.No.2.11 (h) P.No.18 for | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification .All other type of structures
| Tonne | 82961.55 | 82961.55 | 12.48 | False | None | None | False | None | False | 1035360.144 | 0 | 3352226 | 117881 | None | Gescom rates | 2798001-Fish plate with necessary clam | No | 327.09 | 327.09 | 2.0 | False | None | None | False | None | False | 654.18 | 0 | 3352274 | 117881 | None | PWD Common SR Volume 2 S.No. 17.12 P.No.176 for 20 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 974.4 | 974.4 | 320.0 | False | None | None | False | None | False | 311808.0 | 0 | 3352227 | 117881 | None | Gescom rates | Wiring of One circuit of LT Wiring Kit for for 25/63/100 KVA DTC to the existing LT protection Kit Kit /Distribution Box via metering box. | No | 996.45 | 996.45 | 1.0 | False | None | None | False | None | False | 996.45 | 0 | 3352275 | 117881 | None | PWD Common SR Volume 5 S.No. 16.28.1 P.No.198 for | Repairs to Machinehole for different depths including removal of debris, levelling the brick masonry, construction of brick masonry upto Ground level, providing CC coping alround the MH cover, plastering both inside and outside to the brick masonry and fixing of manhole frame and cover, curing, refilling with appurtenances complete.16.28.1 Upto 0.30m depth | No | 8577.45 | 8577.45 | 15.0 | False | None | None | False | None | False | 128661.75 | 0 | 3352228 | 117881 | None | Gescom rates | 281008-8 SWG G.I.Wire | Kg | 92.97 | 92.97 | 5.0 | False | None | None | False | None | False | 464.85 | 0 | 3352276 | 117881 | None | PWD Common SR Volume 3 S.No. 8.55 P.No.78 for 2023 | Providing and fixing board displaying information, such as 'Name of work, ender cost, Name of Contractor, Work completion and liability period etc',having rectangular shape of 1.20m x 0.90m size made out 18 gauge(1.25mm) thick mild steel sheet painted with one coat of Zinc hromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved olour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. Asdirected by Engineer in Charge & MoRTH specification 804
| No | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 | 3352229 | 117881 | None | Gescom rates | 281110-7/10 SWG Guy Wire | Kg | 95.68 | 95.68 | 10.0 | False | None | None | False | None | False | 956.8 | 0 | 3352230 | 117881 | None | Gescom rates | 2811101-Guy with Complete set, Fixing of GUY Sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised
steel wire with turn buckle
and anchoring
arrangement as per
approved drawing.
(Excluding excavation of
PIT) | Set | 1728.93 | 1728.93 | 4.0 | False | None | None | False | None | False | 6915.72 | 0 | 3352231 | 117881 | None | Gescom codes | Ordinary Soil(labour) | No | 343.35 | 343.35 | 1.0 | False | None | None | False | None | False | 343.35 | 0 | 3352232 | 117881 | None | Gescom rates | 2811103-Earthing Materials Type for gr, Ordinary Soil | No | 2939.18 | 2939.18 | 3.0 | False | None | None | False | None | False | 8817.54 | 0 | 3352233 | 117881 | None | Gescom rates | Providing GI Pipe Earthing for lightning
arresters Transformer Neutral and Transformer Metal parts (Excluding
digging of pits)(labour) | No | 199.5 | 199.5 | 3.0 | False | None | None | False | None | False | 598.5 | 0 | 3352234 | 117881 | None | Gescom rates | 283008-11kV, 5KN Composite/Polymeric | No | 253.99 | 253.99 | 3.0 | False | None | None | False | None | False | 761.97 | 0 | 3352235 | 117881 | None | Gescom rates | 283320-Silcon rubber composite insula | No | 230.45 | 230.45 | 3.0 | False | None | None | False | None | False | 691.35 | 0 | 3352236 | 117881 | None | Gescom rates | 284503-LT Spacer for TC Wiring | No | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3352237 | 117881 | None | Gescom rates | 285557-120Sq.mm (P.G. Clamps Rabbit | No | 338.25 | 338.25 | 4.0 | False | None | None | False | None | False | 1353.0 | 0 | 3352238 | 117881 | None | Gescom rates | 288532-120 Sq.mm Copper terminals (Lo | No | 173.46 | 173.46 | 12.0 | False | None | None | False | None | False | 2081.52 | 0 | 3352239 | 117881 | None | Gescom rates | 301107-L.T.Protection kit,Fixing of LT Protection Kit | No | 2880.3 | 2880.3 | 2.0 | False | None | None | False | None | False | 5760.6 | 0 | 3352240 | 117881 | None | Gescom rates | 301230-L.T.Distribution Box for 100,Fixing LT Distribution box for 100/ 250 / 500 KVA
DTCs (Excluding wiring)
| No | 28512.2 | 28512.2 | 1.0 | False | None | None | False | None | False | 28512.2 | 0 | 3352241 | 117881 | None | Gescom rates | 302011-11 kV D.O.L.O Cutouts Convent,Fixing DOLO cutouts /
Horn Gap Fuses including
fixing of cross arms and
wiring | Set of 3 Nos | 7527.98 | 7527.98 | 1.0 | False | None | None | False | None | False | 7527.98 | 0 | 3352242 | 117881 | None | Gescom rates | 303200-L.A. 9kV, 5kA, Metal Oxide, | No | 1139.88 | 1139.88 | 3.0 | False | None | None | False | None | False | 3419.64 | 0 | 3352243 | 117881 | None | Gescom rates | Fixing of 3 Nos lightning
arrestors including wiring(Labour) | No | 124.95 | 124.95 | 1.0 | False | None | None | False | None | False | 124.95 | 0 | 3352244 | 117881 | None | Gescom rates | 304212-11kV G.O.S 200A Single break,Fixing of GOS including
wiring (11kV SB 200A) | Set | 12867.75 | 12867.75 | 1.0 | False | None | None | False | None | False | 12867.75 | 0 | 3352245 | 117881 | None | Gescom rates | 321467-100 Kva,Aluminium wdg,star 2(5,Erection of 100 kVA
Transformer on
Transformer structure. | No | 276668.03 | 276668.03 | 1.0 | False | None | None | False | None | False | 276668.03 | 0 | 3352246 | 117881 | None | Gescom rates | 357510-L.T. Electronic Tri-Vector Met,LT Electroic Tri-Vector
Meter 5A, Class-0.5/1.0
Accuracy | No | 5045.54 | 5045.54 | 1.0 | False | None | None | False | None | False | 5045.54 | 0 | 3352247 | 117881 | None | Gescom rates | 358066-With CT ratio150/5 for 100 kVA,358066-With CT ratio150/5 for 100 kVA | MT | 7995.08 | 7995.08 | 1.0 | False | None | None | False | None | False | 7995.08 | 0 | 3352248 | 117881 | None | Gescom rates | 200006-PSC Pole-9.0M Long,200 kg WL,Erection of RCC/PSC
poles 9 to 10 mtr long but
in a pit of 1.8 mtr depth | No | 6371.21 | 6371.21 | 26.0 | False | None | None | False | None | False | 165651.46 | 0 | 3352249 | 117881 | None | Gescom rates | Ordinary Soil (labour) | No | 660.45 | 660.45 | 26.0 | False | None | None | False | None | False | 17171.7 | 0 | 3352250 | 117881 | None | Gescom rates | 200105-RCC Pole-9.0M Long,145 kg WL,Erection of RCC/PSC
poles 9 to 10 mtr long but
in a pit of 1.8 mtr depth | No | 9935.81 | 9935.81 | 5.0 | False | None | None | False | None | False | 49679.05 | 0 | 3352251 | 117881 | None | Gescom rates | Ordinary Soil(labour) | No | 660.45 | 660.45 | 5.0 | False | None | None | False | None | False | 3302.25 | 0 | 3352252 | 117881 | None | Gescom rates | 27901203-4 pin cross arm with pole clam,Fixing of 4 Pin cross arm
with insulator and Braces
fixing | No | 692.1 | 692.1 | 7.0 | False | None | None | False | None | False | 4844.7 | 0 | 3352253 | 117881 | None | Gescom rates | 283003-1.1kV Pin Insulator (Shell on | No | 38.4 | 38.4 | 13.0 | False | None | None | False | None | False | 499.2 | 0 | 3352254 | 117881 | None | Gescom rates | 283053-1.1kV Pin Insulator (G.I Pin | No | 43.36 | 43.36 | 13.0 | False | None | None | False | None | False | 563.68 | 0 | 3352255 | 117881 | None | Gescom rates | 284105-Weasel ACSR Conductor,Stringing of conductor wren, squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. | Mtr | 47.12 | 47.12 | 400.0 | False | None | None | False | None | False | 18848.0 | 0 | 3352256 | 117881 | None | Gescom rates | 284819-3x95+1x70+1x16 street light (I,Stringing of 1.1kV grade aerial bunched 3 core cable of XLPE insulation standard aluminum conductor, standard around a weather resistant black XLPE insulated AAA messenger wire 1. (3x95) (for Phase conductor) + (1x70) (insulated messenger
neutral) + (1x16) | Km | 646943.2 | 646943.2 | 3.5 | False | None | None | False | None | False | 2264301.2 | 0 | 3352257 | 117881 | None | Gescom rates | 284820-Single phase Distribution box | No | 2974.84 | 2974.84 | 20.0 | False | None | None | False | None | False | 59496.8 | 0 | 3352258 | 117881 | None | Gescom rates | 284822-Piercing connector suitable fo, Installation of Insulation piercing connector for main to service line Main 16-95sqmm, Tap 4-35sqmm(P2X95), | No | 462.74 | 462.74 | 150.0 | False | None | None | False | None | False | 69411.0 | 0 | 3352259 | 117881 | None | Gescom rates | 284825-Dead end clamp / Anchor clamp | No | 188.33 | 188.33 | 20.0 | False | None | None | False | None | False | 3766.6 | 0 | 3352260 | 117881 | None | Gescom rates | 284826-Suspension clamp assembly 25t,Erection of Suspension Clamp - 25 to 95 sqmm insulated messenger with bracket | No | 521.85 | 521.85 | 50.0 | False | None | None | False | None | False | 26092.5 | 0 | 3352261 | 117881 | None | Gescom rates | 900369-Group C A) 24 Watts | Each | 5250.0 | 5250.0 | 10.0 | False | None | None | False | None | False | 52500.0 | 0 | 3352262 | 117881 | None | Gescom rates | Installation of Insulation piercing connector for main to street light Main : 16-95sqmm, Tap : 1.5- 10sqmm(EP95)
| No | 94.5 | 94.5 | 150.0 | False | None | None | False | None | False | 14175.0 | 0 |
|
|
---|