| 3494795 | 124784 | None | Item1 | KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) | Cum | 105.06 | 105.06 | 423.32 | False | None | None | False | None | False | 44473.9992 | 0 |
| 3494796 | 124784 | None | Item2 | KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No.2.1.2 Page No.15 Vol.1 PWD SR) | Cum | 5833.92 | 5833.92 | 251.2 | False | None | None | False | None | False | 1465480.704 | 0 |
| 3494797 | 124784 | None | Item3 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) | Cum | 7192.8 | 7192.8 | 380.83 | False | None | None | False | None | False | 2739234.024 | 0 |
| 3494798 | 124784 | None | Item4 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) | Cum | 11210.4 | 11210.4 | 41.8 | False | None | None | False | None | False | 468594.72 | 0 |
| 3494799 | 124784 | None | Item6 | KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) | Cum | 9694.08 | 9694.08 | 23.37 | False | None | None | False | None | False | 226550.6496 | 0 |
| 3494800 | 124784 | None | Item7 | KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing andtechnical specification. (Item No. 2.11.A Page No. 18 Vol.1 PWD SR) | Tonne | 92140.71 | 92140.71 | 27.1811 | False | None | None | False | None | False | 2504485.852581 | 0 |
| 3494801 | 124784 | None | Item8 | KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) | Cum | 6580.67 | 6580.67 | 111.98 | False | None | None | False | None | False | 736903.4266 | 0 |
| 3494802 | 124784 | None | Item9 | KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) | Cum | 488.22 | 488.22 | 2508.38 | False | None | None | False | None | False | 1224641.2836 | 0 |
| 3494803 | 124784 | None | Item10 | KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) | Sqm | 1267.93 | 1267.93 | 489.24 | False | None | None | False | None | False | 620322.0732 | 0 |
| 3494804 | 124784 | None | Item11 | KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2) | Sqm | 303.85 | 303.85 | 1016.9 | False | None | None | False | None | False | 308985.065 | 0 |
| 3494805 | 124784 | None | Item12 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) | Kgs | 116.39 | 116.39 | 93450.0 | False | None | None | False | None | False | 10876645.5 | 0 |
| 3494806 | 124784 | None | Item13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) | Sqm | 585.04 | 585.04 | 3842.93 | False | None | None | False | None | False | 2248267.7672 | 0 |
| 3494807 | 124784 | None | Item14 | KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2) | Sqm | 103.0 | 103.0 | 1016.9 | False | None | None | False | None | False | 104740.7 | 0 |
| 3494808 | 124784 | None | Item15 | KSRB 8.54.1Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | Sqm | 75.19 | 75.19 | 953.41 | False | None | None | False | None | False | 71686.8979 | 0 |
| 3494809 | 124784 | None | Item16 | KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) | Sqm | 2711.99 | 2711.99 | 57.38 | False | None | None | False | None | False | 155613.9862 | 0 |
| 3494810 | 124784 | None | Item17 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) | Each | 25426.58 | 25426.58 | 3.0 | False | None | None | False | None | False | 76279.74 | 0 |
| 3494811 | 124784 | None | Item18 | KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2) | Kg | 465.56 | 465.56 | 1020.0 | False | None | None | False | None | False | 474871.2 | 0 |
| 3494812 | 124784 | None | Item19 | SupplyingandfixingMouldedCaseCircuitBreaker(MCCB)overtheexistingwood/panelboardusingnecessaryscrews,bolts,nuts,necessaryphaseseparators,handleandwiringcomplete.ProtectionofOverloadandShortcircuitwithadjustablethermalmagneticrelease,MicroprocessorreleaseshallhaveEarthFaultasperIS/IEC60947-2.(Icu=100%lcs).In4PMCCB,allPolesshouldhaveprotectionforShort-Cicrcuit/ Over Load. For Microprocessor MCCBSFacilityforsegregatingPriorityandNon PriorityloadsmustbeavailableintheMCCB.MCCBshallbeprovidedwithdoubleinsulation(insulationbetweenfrontcoverandinternalpowercircuitstoavoidanyaccidentalcontactwithlivecurrentcarryingpathwiththefrontcoveropen).Multi-polebreakersshallbedesignedtobreakallthepolessimultaneously and they shall have a single mechanism 250 A 25 kA (p.no.17.i.no.5.15.5) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Each | 16973.0 | 16973.0 | 2.0 | False | None | None | False | None | False | 33946.0 | 0 |
| 3494813 | 124784 | None | Item20 | 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 1995 3x95 + 1x70 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral) (P.no.18.i.no.42.03) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Km | 494091.0 | 494091.0 | 0.15 | False | None | None | False | None | False | 74113.65 | 0 |
| 3494814 | 124784 | None | Item21 | 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 3x95 + 1x70 + 1x25 Sqmm Street light (Insulated Messenger cum Neutral) (P.no.18.i.no.42.04) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Km | 506358.0 | 506358.0 | 0.2 | False | None | None | False | None | False | 101271.6 | 0 |
| 3494815 | 124784 | None | Item22 | 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 3x95 + 1x70 + 1x35 Sqmm Street light (Insulated Messenger cum Neutral) (P.no.18.i.no.42.05) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Km | 528639.0 | 528639.0 | 0.15 | False | None | None | False | None | False | 79295.85 | 0 |
| 3494816 | 124784 | None | Item23 | 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 3x70 + 1x50 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral) (P.no.18.i.no.42.06) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Km | 376197.0 | 376197.0 | 0.2 | False | None | None | False | None | False | 75239.4 | 0 |
| 3494817 | 124784 | None | Item24 | 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 3x25 + 1x25 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral) (P.no.18.i.no.42.07) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Km | 164831.0 | 164831.0 | 0.15 | False | None | None | False | None | False | 24724.65 | 0 |
| 3494818 | 124784 | None | Item25 | 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 3x16 + 1x25 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral) (P.no.18.i.no.42.08) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Km | 108767.0 | 108767.0 | 0.15 | False | None | None | False | None | False | 16315.05 | 0 |
| 3494819 | 124784 | None | Item26 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm (P.no.52.i.no.21.06) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Km | 31139.0 | 31139.0 | 1.0 | False | None | None | False | None | False | 31139.0 | 0 |
| 3494820 | 124784 | None | Item27 | 1 x 1000 Sq mm, 11 kV Heat Shrinkable Cable termination kit for XLPE Cable Out door (P.no.73.i.no.50.3.2) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | No | 4060.0 | 4060.0 | 50.0 | False | None | None | False | None | False | 203000.0 | 0 |
| 3494821 | 124784 | None | Item28 | Heat Shrinkable Straight Through Jointing Kit for PILC Cable with Copper Lug & Al Ferrul 3x95 Sqmm (P.no.21.i.no.45.19) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Set | 7798.0 | 7798.0 | 50.0 | False | None | None | False | None | False | 389900.0 | 0 |
| 3494822 | 124784 | None | Item29 | Fabricating supplying and mounting MS boxmade out. SWG suitable for floor/wallmounting, fully weather proof with provision for better heatdissipation, provided withhinged front cover,equipped witht amperprooflockingarrangements, with suitable size clamps with necessary cable entry pipe withg land and box shouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. (p.no.20.i.no.5.42.1) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | Sqm | 0.5 | 0.5 | 75000.0 | False | None | None | False | None | False | 37500.0 | 0 |
| 3494823 | 124784 | None | Item30 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick (P.no.2.it.no.1.1.1) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 69.0 | 69.0 | 999.96 | False | None | None | False | None | False | 68997.24 | 0 |
| 3494824 | 124784 | None | Item31 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick (P.no.2.it.no.1.1.2) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 81.0 | 81.0 | 1000.0 | False | None | None | False | None | False | 81000.0 | 0 |
| 3494825 | 124784 | None | Item32 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thick (P.no.2.it.no.1.1.3) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 106.0 | 106.0 | 1200.0 | False | None | None | False | None | False | 127200.0 | 0 |
| 3494826 | 124784 | None | Item33 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5 mm thick (P.no.2.it.no.1.1.4) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 149.0 | 149.0 | 1200.0 | False | None | None | False | None | False | 178800.0 | 0 |
| 3494827 | 124784 | None | Item34 | PVC/metal conduit Deep Junction Box Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box (P.no.2.it.no.1.5.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 49.0 | 49.0 | 50.0 | False | None | None | False | None | False | 2450.0 | 0 |
| 3494828 | 124784 | None | Item35 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8" x 6" x 3" (203 x 152 x 76 mm) (P.no.3.it.no.1.6.4) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 86.0 | 86.0 | 10.0 | False | None | None | False | None | False | 860.0 | 0 |
| 3494829 | 124784 | None | Item36 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 4" x 4" x 3" ( 101 x 101 x 76 mm) (P.no.3.it.no.1.6.6) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 74.0 | 74.0 | 10.0 | False | None | None | False | None | False | 740.0 | 0 |
| 3494830 | 124784 | None | Item37 | Wiring for Lightings/Power Circuit Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1 Sqmm (P.no.5.it.no.2.3.1) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 19.0 | 19.0 | 1100.0 | False | None | None | False | None | False | 20900.0 | 0 |
| 3494831 | 124784 | None | Item38 | Wiring for Lightings/Power Circuit Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 Sqmm (P.no.5.it.no.2.3.2) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 26.0 | 26.0 | 1100.0 | False | None | None | False | None | False | 28600.0 | 0 |
| 3494832 | 124784 | None | Item39 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmm (P.no.5.it.no.2.3.3) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 42.0 | 42.0 | 1100.0 | False | None | None | False | None | False | 46200.0 | 0 |
| 3494833 | 124784 | None | Item40 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 Sqmm (P.no.5.it.no.2.3.4) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 63.0 | 63.0 | 800.0 | False | None | None | False | None | False | 50400.0 | 0 |
| 3494834 | 124784 | None | Item41 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 Sqmm (P.no.5.it.no.2.3.5) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 92.0 | 92.0 | 500.0 | False | None | None | False | None | False | 46000.0 | 0 |
| 3494835 | 124784 | None | Item42 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way (P.no.9.it.no.3.6.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 102.0 | 102.0 | 25.0 | False | None | None | False | None | False | 2550.0 | 0 |
| 3494836 | 124784 | None | Item43 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps two way. (P.no.9.it.no.3.6.2) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 166.0 | 166.0 | 20.0 | False | None | None | False | None | False | 3320.0 | 0 |
| 3494837 | 124784 | None | Item44 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch (P.no.9.it.no.3.6.7) .(PWD CSR for Electrical Works for the Year 2023-24) | Each | 180.0 | 180.0 | 15.0 | False | None | None | False | None | False | 2700.0 | 0 |
| 3494838 | 124784 | None | Item45 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch. (P.no.9.it.no.3.6.9) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 326.0 | 326.0 | 10.0 | False | None | None | False | None | False | 3260.0 | 0 |
| 3494839 | 124784 | None | Item46 | 4mm Thick Plastic Sheets Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. (P.no.9.it.no.3.8) (PWD CSR for Electrical Works for the Year 2023-24) | Sq CM | 0.41 | 0.41 | 3000.0 | False | None | None | False | None | False | 1230.0 | 0 |
| 3494840 | 124784 | None | Item47 | Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps (P.no.10.it.no.5.7.2) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 241.0 | 241.0 | 6.0 | False | None | None | False | None | False | 1446.0 | 0 |
| 3494841 | 124784 | None | Item48 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (p.no.17.it.no.5.18.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 415.0 | 415.0 | 10.0 | False | None | None | False | None | False | 4150.0 | 0 |
| 3494842 | 124784 | None | Item49 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP .(p.no.17.it.no.5.18.4) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 739.0 | 739.0 | 4.0 | False | None | None | False | None | False | 2956.0 | 0 |
| 3494843 | 124784 | None | Item50 | MCB Distribution Boards Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door 8 Way SP & N (p.no.18.it.no.5.19.3)(PWD CSR for Electrical Works for the Year 2023-24) | Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 |
| 3494844 | 124784 | None | Item51 | PVC Batten with LED Tubes Supplying of .feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4' 20/22 w (p.no.43.it.no.11.3.2) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 690.0 | 690.0 | 25.0 | False | None | None | False | None | False | 17250.0 | 0 |
| 3494845 | 124784 | None | Item52 | LED Down Lights Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W (p.no.43.it.no.11.5.3) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 1324.0 | 1324.0 | 20.0 | False | None | None | False | None | False | 26480.0 | 0 |
| 3494846 | 124784 | None | Item53 | Lamp Holder Supplying & Fixing of 70-150 Watts lamp holder 2 Pin (p.no.52.it.no.12.46) (PWD CSR for Electrical Works for the Year 2023-24) | No | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 |
| 3494847 | 124784 | None | Item54 | Fixing all type of Luminaries Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders (p.no.56.it.no.13.7.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 122.0 | 122.0 | 25.0 | False | None | None | False | None | False | 3050.0 | 0 |
| 3494848 | 124784 | None | Item55 | Fixing of LED Lights Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.(p.no.58.it.no.13.19) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 490.0 | 490.0 | 45.0 | False | None | None | False | None | False | 22050.0 | 0 |
| 3494849 | 124784 | None | Item56 | Supplying, fixing, wiring, earthelectrode for grounding conduits, I.C. cutout sand other equipment' sonthemeter boardusing 40mmdia 2.90mm thick GI pipe 2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-round the pipe tocomplete depth. The connection fromthepipetothe conduit etc.,istobeestablishedthrough GI wire of size asper lSI specification7.3.3.of IS732 using12mm dia bolts,nuts,washer sand check nuts etc., the pipe shall have 16 through holes of 12 mm dia . (PWD CSR for Electrical Works for the Year 2023-24 P.no.54.it.no.12.56) | Each | 3510.0 | 3510.0 | 6.0 | False | None | None | False | None | False | 21060.0 | 0 |
| 3494850 | 124784 | None | Item57 | DAS Specification Compact RMU (VCB/SF6 Type) as per IEC-62271The DAS RMUs shall have the following in addition to the Standards: DC motors, Numerical Relays, Multi-functional meters, fault passage indicator (FPI), Metering CTs, Protection CTs, Auxiliary transformers, Potential transformer, Batteries, Battery chargers (12 V & 24 V), AC power socket and light for illumination of Control panel. Control cable from each panel shall be wired and terminated to suitable 24 pin connector in the control panel. Suitable space for fixing the Remote Terminal Unit (RTU) and Radio Modem in Control panel. Suitable Clamps for fixing Antenna Pipe 1 VL for RMU, 630 Amps Copper Busbar (P.no.17.it.no.40.04) (PWD CSR for Electrical Works for the Year 2023-24) | Unit | 290938.0 | 290938.0 | 2.0 | False | None | None | False | None | False | 581876.0 | 0 |
| 3494851 | 124784 | None | Item58 | SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm (p.no.20.i.no.5.41.2) ENERGY DEPARTMENT COMMON SCHEDULE OF RATESFOR KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6 | m | 395.0 | 395.0 | 50.0 | False | None | None | False | None | False | 19750.0 | 0 |