| 1721442856000 | 0 | None | None | Other Works | Construction of Main Gate And Kaman at Serve No 129 of SWM Center | 324178.38 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3560124 | 128915 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 126.37 | 126.37 | 4.3199 | False | None | None | False | None | False | 545.905763 | 0 | | 3560125 | 128915 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7017.69 | 7017.69 | 0.576 | False | None | None | False | None | False | 4042.18944 | 0 | | 3560126 | 128915 | None | code03 | Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - For Buildings | Tonne | 110837.22 | 110837.22 | 0.0238 | False | None | None | False | None | False | 2637.925836 | 0 | | 3560127 | 128915 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8214.57 | 8214.57 | 0.63 | False | None | None | False | None | False | 5175.1791 | 0 | | 3560128 | 128915 | None | code05 | Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. | Sqm | 410.72 | 410.72 | 0.63 | False | None | None | False | None | False | 258.7536 | 0 | | 3560129 | 128915 | None | code06 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Kgs | 182.13 | 182.13 | 1101.777 | False | None | None | False | None | False | 200666.64501 | 0 | | 3560130 | 128915 | None | code07 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 172.22 | 172.22 | 51.1 | False | None | None | False | None | False | 8800.442 | 0 | | 3560131 | 128915 | None | code08 | Supply and Fixing of Radium Stickar Work | Lot | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | | 3560132 | 128915 | None | code09 | Supply of LED Street light luminaries with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection molded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT grather than 5500 K, IP66 optical and electrical compartment & impact resistance of complete luminaries grather than IK08. Power Factor grather than 0.9 with mains, Surge Protection-Min 5KV along with Over voltage/ Overload, shortcircuit / miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver too pirate wide voltage range from 100V to 270 V 50/60 Hz application. Compliance to IS10322/ IEC60598, LM79 & LM 80 Adherence with Ro HS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........W System Power consumption. LED Efficiency grather than 1301m/w, nominal CRI grather than 75. Luminaries manufacturer should havein-house facility accredited by NABL / CPRI & any Government certified agency & Design and Development facility certified by ISO9001:2008. Housing with supplier word mark /names hallbe Engraved /Embossing on the die cast housing /Body part. Warranty of 2Years against any manufacturing defect working under stand and electrical conditions as mentioned above should be given by LED manufacturer and Cree /Nichia/Lumileds/Osram make LED Source. LED Streetlight 70W | Each | 7424.08 | 7424.08 | 2.0 | False | None | None | False | None | False | 14848.16 | 0 | | 3560133 | 128915 | None | code10 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 | Mtr | 44.1 | 44.1 | 15.0 | False | None | None | False | None | False | 661.5 | 0 | | 3560134 | 128915 | None | code11 | Supplying and Fixing of 25mm dia class A GI pipe bracket upto 1 ms long bent at suitable angle and fixing to this bracket street ligh tfitting of all capacities to GI or GIorrailor RCC pole/wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | Each | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | | 3560135 | 128915 | None | code12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 126.37 | 126.37 | 1.0 | False | None | None | False | None | False | 126.37 | 0 | | 3560136 | 128915 | None | code13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingkg | Kg | 208.15 | 208.15 | 352.7999 | False | None | None | False | None | False | 73435.299185 | 0 |
|