| 3568180 | 129449 | None | code01 | Earth work excavation for Foundation by mechanical means for all works and depth up to 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of excavated surfaces disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labor tools usage of machinery and other appurtenances required to complete the work | Cum | 114.24 | 114.24 | 31.21 | False | None | None | False | None | False | 3565.4304 | 0 |
| 3568181 | 129449 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labor Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications Using 40 mm nominal size graded crushed coarse aggregates The cost of steel reinforcement & formwork shall be paid separately | Cum | 6343.68 | 6343.68 | 27.34 | False | None | None | False | None | False | 173436.2112 | 0 |
| 3568182 | 129449 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead & lifts cost of all materials quality confirming to the requirements of relevant IS codes labor Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement & formwork to be paid separately M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Footing | Cum | 7776.0 | 7776.0 | 7.4 | False | None | None | False | None | False | 57542.4 | 0 |
| 3568183 | 129449 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead & lifts cost of all materials quality confirming to the requirements of relevant IS codes labor Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement & formwork to be paid separately M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Column base | Cum | 11016.0 | 11016.0 | 1.45 | False | None | None | False | None | False | 15973.2 | 0 |
| 3568184 | 129449 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead & lifts cost of all materials quality confirming to the requirements of relevant IS codes labor Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement & formwork to be paid separately M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Hall Grade slab | Cum | 7776.0 | 7776.0 | 29.9 | False | None | None | False | None | False | 232502.4 | 0 |
| 3568185 | 129449 | None | code06 | Providing and laying in Reinforced cement concrete for all Basementandsurface level works return walls retaining walls sunken floors etc The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers well compacted using needle vibrators providing weep holes wherever necessary including all lead & lifts cost of all materials of quality labor Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10264.32 | 10264.32 | 4.68 | False | None | None | False | None | False | 48037.0176 | 0 |
| 3568186 | 129449 | None | code07 | Steel Fabrication Supplying fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials machinery labor cleaning straightening
cutting bending hooking lapping welding joints tying with binding wire soft
annealed steel wire and other ancillary operations complete as per drawing and
technical specification | t | 100191.84 | 100191.84 | 2.83 | False | None | None | False | None | False | 283542.9072 | 0 |
| 3568187 | 129449 | None | code08 | Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar | Cum | 7155.68 | 7155.68 | 13.65 | False | None | None | False | None | False | 97675.032 | 0 |
| 3568188 | 129449 | None | code09 | Construction of Embankment by excavating the available approved Gravel Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead transportation to site spreading grading to required slope and compacting to meet the requirement complete as per specifications including cost of labour rolling water all materials usage and all other appurtenaces required to complete the work | Cum | 530.88 | 530.88 | 134.54 | False | None | None | False | None | False | 71424.5952 | 0 |
| 3568189 | 129449 | None | code10 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I- 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials labour scaffolding and curing usage charges of machinery etc complete as per specifications | Sqm | 1378.72 | 1378.72 | 101.7 | False | None | None | False | None | False | 140215.824 | 0 |
| 3568190 | 129449 | None | code11 | Providing 15mm cement plaster of mix :1:4 1 cement: 4 fine sand to brick/stone masonary including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge | Sqm | 330.4 | 330.4 | 216.9 | False | None | None | False | None | False | 71663.76 | 0 |
| 3568191 | 129449 | None | code12 | Providing and fixing Structural Steel work riveted bolted or welded in built up sections trusses and framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete including cost of materials labou, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge | Kg | 126.56 | 126.56 | 7160.0 | False | None | None | False | None | False | 906169.6 | 0 |
| 3568192 | 129449 | None | code13 | Providing and fixing precoated galvanised iron profile sheets size shape and pitch of corrugation as approved by Engineer-in-charge 0.50 mm 0.05 % total coated thickness with zinc coating 120 g/m2 as per IS: 277 in 240 mpa steel grade 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge The sheet shall be fixed using self drilling self tapping screws of size 5.5x 55 mm with EPDM seal, complete upto any pitch in horizontal vertical or curved surfaces excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required | Sqm | 585.04 | 585.04 | 515.14 | False | None | None | False | None | False | 301377.5056 | 0 |
| 3568193 | 129449 | None | code14 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge | Sqm | 112.0 | 112.0 | 216.9 | False | None | None | False | None | False | 24292.8 | 0 |
| 3568194 | 129449 | None | code15 | Wall painting with premium acrylic emulsion paint of interior grade having VOC Volatile Organic Compound content less than 50 g/L of approved brand and manufacture including applying additional coats wherever required to achieve even shade and colour One coat as per specifications and as per directions of Engineer in charge | No | 81.76 | 81.76 | 101.7 | False | None | None | False | None | False | 8314.992 | 0 |
| 3568195 | 129449 | None | code16 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade Old work one coats applied at 0.83 l/10 m² including preparing the surface after thoroughly cleaning the surface to remove all dirt dust and foreign matter cost of materials labour complete as per specifications and as per directions of Engineer-in-charge | No | 81.76 | 81.76 | 101.7 | False | None | None | False | None | False | 8314.992 | 0 |
| 3568196 | 129449 | None | code17 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 part 1 and M.S top cover of required thickness for rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charg | Sqm | 2948.96 | 2948.96 | 22.5 | False | None | None | False | None | False | 66351.6 | 0 |
| 3568197 | 129449 | None | code18 | Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge | No | 27648.32 | 27648.32 | 2.0 | False | None | None | False | None | False | 55296.64 | 0 |
| 3568198 | 129449 | None | code19 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specification | Kg | 506.24 | 506.24 | 240.0 | False | None | None | False | None | False | 121497.6 | 0 |
| 3568199 | 129449 | None | code20 | Supply, erection, testing and commissioning of LT Control Panel panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted,degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners.The switchboards are to be tested as per IS 8623-1977 specifications.Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height.
Main Panel
Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required
SE Approved Rate
63A 4 Wire 16kA 415V Aluminium busbars compartment.
Outgoings: 40/63A 4P MCB feeder- 10Nos
Outgoings: 32A Industrial socket-04Nos
Outgoings: 16A Industrial socket-04Nos. | No | 75000.0 | 75000.0 | 1.0 | False | None | None | False | None | False | 75000.0 | 0 |
| 3568200 | 129449 | None | code21 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 200449.76 | 200449.76 | 0.125 | False | None | None | False | None | False | 25056.22 | 0 |
| 3568201 | 129449 | None | code22 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) | Km | 201425.28 | 201425.28 | 0.1 | False | None | None | False | None | False | 20142.528 | 0 |
| 3568202 | 129449 | None | code23 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 141842.0 | 141842.0 | 0.05 | False | None | None | False | None | False | 7092.1 | 0 |
| 3568203 | 129449 | None | code24 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 132164.48 | 132164.48 | 0.05 | False | None | None | False | None | False | 6608.224 | 0 |
| 3568204 | 129449 | None | code25 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
1.1 kV Class Armoured Aluminium Cable with glands 4C x 6 Sq mm | m | 302.4 | 302.4 | 40.0 | False | None | None | False | None | False | 12096.0 | 0 |
| 3568205 | 129449 | None | code26 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 1.1 kV Class Armoured Aluminium Cable with
Supplying and drawing Flexible Multicore Cable manufactured
with electrolytic grade flexible copper with low conductor
confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed
suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 6 mm2 ,CSR Electrical SR-2023-24 | m | 283.36 | 283.36 | 40.0 | False | None | None | False | None | False | 11334.4 | 0 |
| 3568206 | 129449 | None | code27 | LT Cables Supply & laying 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
3C x 4 mm2 CSR Electrical SR-2023-24, ITEM NO:2.5.15 ,CH-2, PAGE NO-5 | m | 192.64 | 192.64 | 75.0 | False | None | None | False | None | False | 14448.0 | 0 |
| 3568207 | 129449 | None | code28 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.
3.5Cx50 Sqmm Al Ar cable | Set | 385.0 | 385.0 | 8.0 | False | None | None | False | None | False | 3080.0 | 0 |
| 3568208 | 129449 | None | code29 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.
4Cx25 Sqmm Al Ar cable | Set | 250.0 | 250.0 | 10.0 | False | None | None | False | None | False | 2500.0 | 0 |
| 3568209 | 129449 | None | code30 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.
4Cx16 Sqmm Al Ar cable
SE Approved Rate | Set | 225.0 | 225.0 | 12.0 | False | None | None | False | None | False | 2700.0 | 0 |
| 3568210 | 129449 | None | code31 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.
4Cx10 Sqmm Cu Ar cable | Set | 200.0 | 200.0 | 14.0 | False | None | None | False | None | False | 2800.0 | 0 |
| 3568211 | 129449 | None | code32 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.
4Cx6.0 Sqmm Cu Ar cable | Set | 185.0 | 185.0 | 14.0 | False | None | None | False | None | False | 2590.0 | 0 |
| 3568212 | 129449 | None | code33 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.
3Cx6.0 Sqmm Cu Un Ar cable
| Set | 145.0 | 145.0 | 16.0 | False | None | None | False | None | False | 2320.0 | 0 |
| 3568213 | 129449 | None | code34 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.
3Cx4.0 Sqmm Cu Un Ar cable | Set | 138.0 | 138.0 | 12.0 | False | None | None | False | None | False | 1656.0 | 0 |
| 3568214 | 129449 | None | code35 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.
Pre - Insulated Lug - CPTAU for 25 Sqmm (SL No 323., I.No.43.25,ESCOMs SR 2023-24) | Set | 321.44 | 321.44 | 8.0 | False | None | None | False | None | False | 2571.52 | 0 |
| 3568215 | 129449 | None | code36 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.
Pre - Insulated Lug - CPTAU for 16 Sqmm (SL No 324., I.No.43.26,ESCOMs SR 2023-24) | Set | 159.04 | 159.04 | 8.0 | False | None | None | False | None | False | 1272.32 | 0 |
| 3568216 | 129449 | None | code37 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.
10 Sqmm Cu Ar cable (tinned copper lug)
| Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 |
| 3568217 | 129449 | None | code38 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.
6.0 Sqmm Cu Ar cable (tinned copper lug)
| Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 |
| 3568218 | 129449 | None | code39 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.
6.0 Sqmm Cu Un Ar cable (tinned copper lug)
| Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 |
| 3568219 | 129449 | None | code40 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.
4.0 Sqmm Cu Un Ar cable (tinned copper lug)
| Set | 10.0 | 10.0 | 8.0 | False | None | None | False | None | False | 80.0 | 0 |
| 3568220 | 129449 | None | code41 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR 2023-24, Page No-2, Item 1.1
19/20mm dia PVC 2mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-1) | m | 77.28 | 77.28 | 125.0 | False | None | None | False | None | False | 9660.0 | 0 |
| 3568221 | 129449 | None | code42 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR 2023-24, Page No-2, Item 1.1
25mm dia PVC 2mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-1 ) | m | 90.72 | 90.72 | 125.0 | False | None | None | False | None | False | 11340.0 | 0 |
| 3568222 | 129449 | None | code43 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR 2023-24, Page No-2, Item 1.1
32mm dia PVC 2.5mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-1 ) | m | 118.72 | 118.72 | 100.0 | False | None | None | False | None | False | 11872.0 | 0 |
| 3568223 | 129449 | None | code44 | PVC conduits & Accessories
Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Ele SR 2023-24, Page No-2, Item 1.1
40mm dia PVC 2mm thick conduit (CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-1) | m | 166.88 | 166.88 | 100.0 | False | None | None | False | None | False | 16688.0 | 0 |
| 3568224 | 129449 | None | code45 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1
Short point upto 3Mtr from tapping point to out let via switch (CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-2, PAGE NO-4) | Nos | 319.2 | 319.2 | 2.0 | False | None | None | False | None | False | 638.4 | 0 |
| 3568225 | 129449 | None | code46 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1
Medium point above 3Mtr upto 6Mtr from tapping point to out let
via switch (CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-2, PAGE NO-4) | Nos | 441.28 | 441.28 | 5.0 | False | None | None | False | None | False | 2206.4 | 0 |
| 3568226 | 129449 | None | code47 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1
Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch (CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-2, PAGE NO-4) | Nos | 638.4 | 638.4 | 10.0 | False | None | None | False | None | False | 6384.0 | 0 |
| 3568227 | 129449 | None | code48 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1
Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to
out let via switches. (CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-2, PAGE NO-4) | Nos | 792.96 | 792.96 | 4.0 | False | None | None | False | None | False | 3171.84 | 0 |
| 3568228 | 129449 | None | code49 | Point wiring using Copper wire with switch
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral)&1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copperwire (confirming to IS-694:and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Ele SR 2023-24, Page No-5, Item 2.1
Three outlet in a row, above 6Mts upto 10Mtr from tapping point to
out let via switches (CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-2, PAGE NO-4) | Nos | 1159.2 | 1159.2 | 4.0 | False | None | None | False | None | False | 4636.8 | 0 |
| 3568229 | 129449 | None | code50 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010
1.0 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-2, PAGE NO-4) | m | 21.28 | 21.28 | 219.0 | False | None | None | False | None | False | 4660.32 | 0 |
| 3568230 | 129449 | None | code51 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2011
1.5 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-2, PAGE NO-4) | m | 29.12 | 29.12 | 225.0 | False | None | None | False | None | False | 6552.0 | 0 |
| 3568231 | 129449 | None | code52 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2011
2.5 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-2, PAGE NO-4) | m | 47.04 | 47.04 | 225.0 | False | None | None | False | None | False | 10584.0 | 0 |
| 3568232 | 129449 | None | code53 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2011
4.0 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-2, PAGE NO-4) | m | 70.56 | 70.56 | 125.0 | False | None | None | False | None | False | 8820.0 | 0 |
| 3568233 | 129449 | None | code54 | Circuit main wiring
Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2011
6.0 Sqmm Cu FRLS wire (CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-2, PAGE NO-4) | m | 103.04 | 103.04 | 75.0 | False | None | None | False | None | False | 7728.0 | 0 |
| 3568234 | 129449 | None | code55 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293.
6A one way switch (CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-8) | Nos | 114.24 | 114.24 | 10.0 | False | None | None | False | None | False | 1142.4 | 0 |
| 3568235 | 129449 | None | code56 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293.
6A Three Way socket (CSR Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-8) | Nos | 191.52 | 191.52 | 5.0 | False | None | None | False | None | False | 957.6 | 0 |
| 3568236 | 129449 | None | code57 | Suppl+ying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator Two Module (CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-8) | Nos | 399.84 | 399.84 | 5.0 | False | None | None | False | None | False | 1999.2 | 0 |
| 3568237 | 129449 | None | code58 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293.
6/16A Universal socket (CSR Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-8) | Nos | 264.32 | 264.32 | 4.0 | False | None | None | False | None | False | 1057.28 | 0 |
| 3568238 | 129449 | None | code59 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 Percntage, CCT more than 5500K IP 66 optical and electrical compartment impact resistance of complete luminaire more than IK08. Power Factor more than0.9 with mains Surge Protection Min 5KV along with Over voltage Overload short circuit mis wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency more than 1301mw, nominal CRI more than 75.Luminaire manufacturer should have inhouse facility accredited by NABL CPRI and any Government certified agency Design Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source | Nos | 10624.32 | 10624.32 | 6.0 | False | None | None | False | None | False | 63745.92 | 0 |
| 3568239 | 129449 | None | code60 | Earthing
GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip (CSR Electrical SR-2023-24, ITEM NO:12.58.3, PAGE NO-53) | m | 143.36 | 143.36 | 64.0 | False | None | None | False | None | False | 9175.04 | 0 |
| 3568240 | 129449 | None | code61 | Earthing
8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM , (SL No 61., I.No.8.02,ESCOMs SR 2023-24) | m | 84044.8 | 84044.8 | 0.032 | False | None | None | False | None | False | 2689.4336 | 0 |
| 3568241 | 129449 | None | code62 | Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall.
Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) (Page No.120., I.No.22 a (ii), KPTCL SCHEDULE OF RATES 2023-24) | m | 844.48 | 844.48 | 25.0 | False | None | None | False | None | False | 21112.0 | 0 |
| 3568242 | 129449 | None | code63 | Pipe earthing
Supplying fixing and wiring earth electrode for grounding of lifts,transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrodeshould be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. CSR Electrical SR-2023-24, ITEM NO:12.57, PAGE NO-54 CH NO-12 | Nos | 4766.72 | 4766.72 | 2.0 | False | None | None | False | None | False | 9533.44 | 0 |
| 3568243 | 129449 | None | code64 | HydraulicExcavatorof0.9m3bucket OperatingCost (Rs.)Excluding GST (PWD common SR 2023-24, Volume-1 Page.No.A-44 & ltem no. 49) | hr | 1350.0 | 1350.0 | 16.0 | False | None | None | False | None | False | 21600.0 | 0 |
| 3568244 | 129449 | None | code65 | Tipper 5.50cum OperatingCost (Rs.)Excluding GST (PWD common SR 2023-24, Volume-1 Page.No.A-47 & ltem no.126) | hr | 1412.0 | 1412.0 | 8.0 | False | None | None | False | None | False | 11296.0 | 0 |
| 3568245 | 129449 | None | code66 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work (Page No. 8 Item No.1.12 COMMON SR 2023-24 VOLUME-1 ). | Cum | 106.4 | 106.4 | 48.64 | False | None | None | False | None | False | 5175.296 | 0 |
| 3568246 | 129449 | None | code67 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (Page No. 15 Item No.-2.1.6 common SR 2023-24 VOLUME-1 ). | Cum | 6992.16 | 6992.16 | 1.0 | False | None | None | False | None | False | 6992.16 | 0 |
| 3568247 | 129449 | None | code68 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ( Page no 26, item no 7.38 Buildings SR 2023-24 Volume-2) | Sqm | 636.16 | 636.16 | 12.6 | False | None | None | False | None | False | 8015.616 | 0 |
| 3568248 | 129449 | None | code69 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification))( Page no 51, item no 6.8.2 Road and Bridge SR 2023-24 VOLUME-3 ). | Sqm | 1300.32 | 1300.32 | 194.58 | False | None | None | False | None | False | 253016.2656 | 0 |
| 3568249 | 129449 | None | code70 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
( Page no 46, item no 8.31,Buildings SR 2023-24 Volume-2 ). | Sqm | 199.36 | 199.36 | 122.28 | False | None | None | False | None | False | 24377.7408 | 0 |
| 3568250 | 129449 | None | code71 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.( Page no 84, item no 11.25.2 ,Building SR 2023-24 Volume-2 ). | Kg | 152.32 | 152.32 | 453.6 | False | None | None | False | None | False | 69092.352 | 0 |
| 3568251 | 129449 | None | code72 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
( Page no 48, item no 8.40,,Buildings SR 2023-24 Volume-2 ). | Sqm | 128.8 | 128.8 | 97.52 | False | None | None | False | None | False | 12560.576 | 0 |