tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1720006131000 | 0 | None | None | Buildings | CONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH PUTTUR IN DAKSHINA KANNADA DISTRICT.(CIVIL WORKS) | 4364043.61 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3444745 | 122316 | None | V1P8S1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 125.55 | 125.55 | 125.4 | False | None | None | False | None | False | 15743.97 | 0 | 3444746 | 122316 | None | V1P8S1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 134.8 | 134.8 | 178.2 | False | None | None | False | None | False | 24021.36 | 0 | 3444747 | 122316 | None | V1P7S1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceed ing 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 351.55 | 351.55 | 160.38 | False | None | None | False | None | False | 56381.589 | 0 | 3444748 | 122316 | None | V2P5S4.1 | Anti termite treatment. Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications | Sqm | 155.95 | 155.95 | 200.06 | False | None | None | False | None | False | 31199.357 | 0 | 3444749 | 122316 | None | V1P15S2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7915.06 | 7915.06 | 21.65 | False | None | None | False | None | False | 171361.049 | 0 | 3444750 | 122316 | None | V1P15S2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For footing & pedestal including Centering and formworks. | Cum | 8973.61 | 8973.61 | 33.08 | False | None | None | False | None | False | 296847.0188 | 0 | 3444751 | 122316 | None | V1P18S2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification) | t | 118226.37 | 118226.37 | 6.89 | False | None | None | False | None | False | 814579.6893 | 0 | 3444752 | 122316 | None | V1P16S2.3.1 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for plinth beam including Centring and form works | Cum | 12534.72 | 12534.72 | 8.9 | False | None | None | False | None | False | 111559.008 | 0 | 3444753 | 122316 | None | V1P16S2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns including Centring and form works . | Cum | 14895.75 | 14895.75 | 10.16 | False | None | None | False | None | False | 151340.82 | 0 | 3444754 | 122316 | None | V1P16S2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Chejjas including Centring and form works . | Cum | 12705.2 | 12705.2 | 2.69 | False | None | None | False | None | False | 34176.988 | 0 | 3444755 | 122316 | None | V1P16S2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintles and Beams including Centring and form works . | Cum | 14019.53 | 14019.53 | 13.26 | False | None | None | False | None | False | 185898.9678 | 0 | 3444756 | 122316 | None | V1P16S2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Roof slab including Centring and form works . | Cum | 13143.31 | 13143.31 | 25.29 | False | None | None | False | None | False | 332394.3099 | 0 | 3444757 | 122316 | None | V2P9S5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples For super structure in CM 1:6. | Cum | 8927.41 | 8927.41 | 44.3 | False | None | None | False | None | False | 395484.263 | 0 | 3444758 | 122316 | None | V2P17S6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1459.05 | 1459.05 | 53.7 | False | None | None | False | None | False | 78350.985 | 0 | 3444759 | 122316 | None | V2P88S11.35.2.2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kg | 754.63 | 754.63 | 25.2 | False | None | None | False | None | False | 19016.676 | 0 | 3444760 | 122316 | None | V2P89S11.37.2 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications | Sqm | 1547.59 | 1547.59 | 1.2 | False | None | None | False | None | False | 1857.108 | 0 | 3444761 | 122316 | None | V2P89S11.36.2 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on both the sids including cost of materials, labour, usage charges of machinery complete as per specifications. | Sqm | 1299.13 | 1299.13 | 1.2 | False | None | None | False | None | False | 1558.956 | 0 | 3444762 | 122316 | None | V2P109S12.86 | Providing & fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8 2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7123.42 | 7123.42 | 36.45 | False | None | None | False | None | False | 259648.659 | 0 | 3444763 | 122316 | None | V2P109S12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7558.23 | 7558.23 | 1.62 | False | None | None | False | None | False | 12244.3326 | 0 | 3444764 | 122316 | None | V2P86S11.34B | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc | Kgs | 241.85 | 241.85 | 575.91 | False | None | None | False | None | False | 139283.8335 | 0 | 3444765 | 122316 | None | V2P100S12.13.1 | Providing sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as specifications. | Cum | 130593.9 | 130593.9 | 0.2 | False | None | None | False | None | False | 26118.78 | 0 | 3444766 | 122316 | None | V2P105S12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick Both side commercial. | Sqm | 4390.36 | 4390.36 | 12.2 | False | None | None | False | None | False | 53562.392 | 0 | 3444767 | 122316 | None | V2P111 S12.93.2 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately).Size 62 x 125mm | m | 1009.7 | 1009.7 | 20.4 | False | None | None | False | None | False | 20597.88 | 0 | 3444768 | 122316 | None | V2P112S12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness | Sqm | 4605.78 | 4605.78 | 7.56 | False | None | None | False | None | False | 34819.6968 | 0 | 3444769 | 122316 | None | V2P69S10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | Nos | 79.3 | 79.3 | 24.0 | False | None | None | False | None | False | 1903.2 | 0 | 3444770 | 122316 | None | V2P104S12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1342.75 | 1342.75 | 4.0 | False | None | None | False | None | False | 5371.0 | 0 | 3444771 | 122316 | None | V2P105S12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1472.26 | 1472.26 | 4.0 | False | None | None | False | None | False | 5889.04 | 0 | 3444772 | 122316 | None | V2P105S12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1390.32 | 1390.32 | 4.0 | False | None | None | False | None | False | 5561.28 | 0 | 3444773 | 122316 | None | V2P105S12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. Complete | Nos | 1308.38 | 1308.38 | 4.0 | False | None | None | False | None | False | 5233.52 | 0 | 3444774 | 122316 | None | V2P105S12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 313.22 | 313.22 | 8.0 | False | None | None | False | None | False | 2505.76 | 0 | 3444775 | 122316 | None | V2P105S12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete | Nos | 171.81 | 171.81 | 8.0 | False | None | None | False | None | False | 1374.48 | 0 | 3444776 | 122316 | None | V2P105S12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 72.69 | 72.69 | 4.0 | False | None | None | False | None | False | 290.76 | 0 | 3444777 | 122316 | None | V2P107S12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Nos | 363.44 | 363.44 | 12.0 | False | None | None | False | None | False | 4361.28 | 0 | 3444778 | 122316 | None | V2PA-25S447 | Providing & Fixing of honnewood beeding 10mm wide. | Rmtr | 33.04 | 33.04 | 24.3 | False | None | None | False | None | False | 802.872 | 0 | 3444779 | 122316 | None | V2P60S9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1513.23 | 1513.23 | 155.7 | False | None | None | False | None | False | 235609.911 | 0 | 3444780 | 122316 | None | V2P60S9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete | Sqm | 1174.9 | 1174.9 | 8.3 | False | None | None | False | None | False | 9751.67 | 0 | 3444781 | 122316 | None | V2P71S10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1461.69 | 1461.69 | 71.4 | False | None | None | False | None | False | 104364.666 | 0 | 3444782 | 122316 | None | V2P64S9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications | Sqm | 7041.48 | 7041.48 | 2.7 | False | None | None | False | None | False | 19011.996 | 0 | 3444783 | 122316 | None | V2P63S9.28 | Providing and laying flooring and steps machine cut granite slabs 40mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications | Sqm | 5655.13 | 5655.13 | 2.5 | False | None | None | False | None | False | 14137.825 | 0 | 3444784 | 122316 | None | V2P43S8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 278.86 | 278.86 | 144.6 | False | None | None | False | None | False | 40323.156 | 0 | 3444785 | 122316 | None | V2P41S8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding ,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ( Inside) | Sqm | 368.73 | 368.73 | 646.6 | False | None | None | False | None | False | 238420.818 | 0 | 3444786 | 122316 | None | V2P42S8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) finished rough to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( outside) | Sqm | 508.82 | 508.82 | 316.8 | False | None | None | False | None | False | 161194.176 | 0 | 3444787 | 122316 | None | V2P 47S8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer in charge | Sqm | 70.04 | 70.04 | 29.2 | False | None | None | False | None | False | 2045.168 | 0 | 3444788 | 122316 | None | V2P48S8.40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 151.98 | 151.98 | 29.2 | False | None | None | False | None | False | 4437.816 | 0 | 3444789 | 122316 | None | V2P 48S8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.84 | 167.84 | 791.2 | False | None | None | False | None | False | 132795.008 | 0 | 3444790 | 122316 | None | V2P46S8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 229.96 | 229.96 | 316.8 | False | None | None | False | None | False | 72851.328 | 0 | 3444791 | 122316 | None | V2P47S8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 66.08 | 66.08 | 35.8 | False | None | None | False | None | False | 2365.664 | 0 | 3444792 | 122316 | None | V2P 48S8.40 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 151.98 | 151.98 | 35.8 | False | None | None | False | None | False | 5440.884 | 0 | 3444793 | 122316 | None | V2P84S11.26.3 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes in cluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 241.85 | 241.85 | 82.5 | False | None | None | False | None | False | 19952.625 | 0 |
| 1720006131000 | 0 | None | None | Buildings | CONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH PUTTUR IN DAKSHINA KANNADA DISTRICT.(WATER SUPPLY AND SANITARY WORKS) | 214612.3 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3444794 | 122317 | None | P.No.122 I.No.13.32.3 of Vol.2 of SR 2023-24 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc. 25 mm Dia | m | 630.4 | 630.4 | 50.0 | False | None | None | False | None | False | 31520.0 | 0 | 3444795 | 122317 | None | P.No.122 I.No.13.32.4 of Vol.2 of SR 2023-24 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc. 32 mm Dia | m | 736.13 | 736.13 | 40.0 | False | None | None | False | None | False | 29445.2 | 0 | 3444796 | 122317 | None | P.No.119 I.No.13.12 of Vol.2 of SR 2023-24) | Providing and fixing brass bib cock of approved quality | Nos | 839.22 | 839.22 | 8.0 | False | None | None | False | None | False | 6713.76 | 0 | 3444797 | 122317 | None | P.No.117 I.No.13.4.1 of Vol.2 of SR 2023-24 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore | Nos | 725.56 | 725.56 | 4.0 | False | None | None | False | None | False | 2902.24 | 0 | 3444798 | 122317 | None | P.No.117 I.No.13.4.2 of Vol.2 of SR 2023-24 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore | Nos | 790.32 | 790.32 | 4.0 | False | None | None | False | None | False | 3161.28 | 0 | 3444799 | 122317 | None | P.No.131 I.No.14.1.1 of Vol.2 of SR 2023-24) | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 6454.6 | 6454.6 | 2.0 | False | None | None | False | None | False | 12909.2 | 0 | 3444800 | 122317 | None | V2P124S13.42 of SR 2023-24 | Providing and fixing trap of self ceansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors:*100mm inlet and 100mm outlet.* Sand cast iron S&S as per IS:1729. | Each | 1513.23 | 1513.23 | 8.0 | False | None | None | False | None | False | 12105.84 | 0 | 3444801 | 122317 | None | V2P125S13.48of SR2023-24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS:13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for the thermal expansion,(i) Single socketed pipes 100mm diameter | Rmtr | 384.59 | 384.59 | 55.0 | False | None | None | False | None | False | 21152.45 | 0 | 3444802 | 122317 | None | V1P6S1.6.1of SR 2023-24 | Earth work excavation for pipelines cables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m | Cum | 639.65 | 639.65 | 15.0 | False | None | None | False | None | False | 9594.75 | 0 | 3444803 | 122317 | None | P.No.191 I.No.16.10 of Vol.5 of SR 2023-24) | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Nos | 5598.3 | 5598.3 | 5.0 | False | None | None | False | None | False | 27991.5 | 0 | 3444804 | 122317 | None | Page no.7, item no.1.10 of Vol 1 SR2023-24 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m.Including cost of all labour complete as per specifications. | Cum | 211.46 | 211.46 | 8.0 | False | None | None | False | None | False | 1691.68 | 0 | 3444805 | 122317 | None | V2P123S13.36 of SR 2023-24 | Cutting holes upto 30X30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks. | Each | 426.88 | 426.88 | 20.0 | False | None | None | False | None | False | 8537.6 | 0 | 3444806 | 122317 | None | V2P123S13.37 of SR 2023-24 | Cutting holes upto 15X15cm in RCC floors and roofs for passing drain pipe etc.,and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size)including finishing complete so as to make it leak proof. | Each | 413.66 | 413.66 | 10.0 | False | None | None | False | None | False | 4136.6 | 0 | 3444807 | 122317 | None | Page no.120, item no.13.22.2 of Vol 2 SR2023-24 | Providing and fixing PTMT grating of approved quality and colour, Rectangular type with openable circular lid | Each | 266.96 | 266.96 | 10.0 | False | None | None | False | None | False | 2669.6 | 0 | 3444808 | 122317 | None | Page no.120, item no.13.23 .2of Vol 2 SR2023-24 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D.plastic ball 20 mm nominal bore, 120 mm long, weighing not less than 198 g | Nos | 326.44 | 326.44 | 1.0 | False | None | None | False | None | False | 326.44 | 0 | 3444809 | 122317 | None | Page no.119, item no.13.15 of Vol 2 SR2023-24 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 | Nos | 958.16 | 958.16 | 1.0 | False | None | None | False | None | False | 958.16 | 0 | 3444810 | 122317 | None | Page no.119, item no.13.16 of Vol 2 SR2023-24 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos | 819.39 | 819.39 | 10.0 | False | None | None | False | None | False | 8193.9 | 0 | 3444811 | 122317 | None | Page no.123, item no.13.34 of Vol 2 SR2023-24 | Providing and placing on terrace(at all floor levels), polyethylene water storage tank ,IS:120701 marked,with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tank | l | 11.89 | 11.89 | 2000.0 | False | None | None | False | None | False | 23780.0 | 0 | 3444812 | 122317 | None | V2P124S13.39 of SR 2023-24 | Providing and fixing square mouth S.W.gully trap class SP-1 complete with C.I.grating,brick masonry camber 150X 100 mm size P type with non modular bcommon burnt clay bricks of designation 3.5 & with water tight.C.I cover with frame of 300X300 mm size (inside)the weight of the cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standard design | Each | 3411.05 | 3411.05 | 2.0 | False | None | None | False | None | False | 6822.1 | 0 |
| 1720006131000 | 0 | None | None | Buildings | CONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH PUTTUR IN DAKSHINA KANNADA DISTRICT.(ELECTRICAL WORKS) | 380760.26 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3444813 | 122318 | None | V6S2.2.1 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH. Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.Short point upto 3 mts from tapping point to out let via switch | Point | 355.51 | 355.51 | 22.0 | False | None | None | False | None | False | 7821.22 | 0 | 3444814 | 122318 | None | V6S2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH.Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.Medium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 500.89 | 500.89 | 16.0 | False | None | None | False | None | False | 8014.24 | 0 | 3444815 | 122318 | None | V6S2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH.Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.Long point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 733.49 | 733.49 | 15.0 | False | None | None | False | None | False | 11002.35 | 0 | 3444816 | 122318 | None | V6S3.4.2 | Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 3 way | Each | 210.13 | 210.13 | 13.0 | False | None | None | False | None | False | 2731.69 | 0 | 3444817 | 122318 | None | V6S3.4.3 | Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 4 - 5 way | Each | 233.92 | 233.92 | 12.0 | False | None | None | False | None | False | 2807.04 | 0 | 3444818 | 122318 | None | V6S3.4.4 | Supplying and flush mounting powder coated, Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone cc wall. 6 way , | Each | 290.75 | 290.75 | 6.0 | False | None | None | False | None | False | 1744.5 | 0 | 3444819 | 122318 | None | V6S3.4.5 | Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 8 way | Each | 344.94 | 344.94 | 19.0 | False | None | None | False | None | False | 6553.86 | 0 | 3444820 | 122318 | None | V6 S3.4.7 | Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 16 way | Each | 479.74 | 479.74 | 7.0 | False | None | None | False | None | False | 3358.18 | 0 | 3444821 | 122318 | None | V6 S3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 3 module | Each | 212.78 | 212.78 | 13.0 | False | None | None | False | None | False | 2766.14 | 0 | 3444822 | 122318 | None | V6 S3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 4 module | Each | 231.28 | 231.28 | 12.0 | False | None | None | False | None | False | 2775.36 | 0 | 3444823 | 122318 | None | V6 S3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 6 module | Each | 309.25 | 309.25 | 6.0 | False | None | None | False | None | False | 1855.5 | 0 | 3444824 | 122318 | None | V6 S3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 8 module | Each | 375.33 | 375.33 | 19.0 | False | None | None | False | None | False | 7131.27 | 0 | 3444825 | 122318 | None | V6 S3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 16 module | Each | 524.68 | 524.68 | 7.0 | False | None | None | False | None | False | 3672.76 | 0 | 3444826 | 122318 | None | V6 S3.6.1 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6 amps one way switch | Each | 134.8 | 134.8 | 84.0 | False | None | None | False | None | False | 11323.2 | 0 | 3444827 | 122318 | None | V6 S3.6.3 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6 Amps 3 way sockets | Each | 225.99 | 225.99 | 16.0 | False | None | None | False | None | False | 3615.84 | 0 | 3444828 | 122318 | None | V6 S3.6.4 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. stepped fan Regulator's | Each | 471.81 | 471.81 | 12.0 | False | None | None | False | None | False | 5661.72 | 0 | 3444829 | 122318 | None | V6 S3.6.7 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 16 amps one way switch | Each | 237.89 | 237.89 | 34.0 | False | None | None | False | None | False | 8088.26 | 0 | 3444830 | 122318 | None | V6 S3.6.10 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal sockets | Each | 311.9 | 311.9 | 34.0 | False | None | None | False | None | False | 10604.6 | 0 | 3444831 | 122318 | None | V6 S3.6.9 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch | Each | 430.84 | 430.84 | 3.0 | False | None | None | False | None | False | 1292.52 | 0 | 3444832 | 122318 | None | V6 S1.13 | Supply and fixing one metal Fan box with round hook | Each | 154.63 | 154.63 | 12.0 | False | None | None | False | None | False | 1855.56 | 0 | 3444833 | 122318 | None | V6 S1.2.1 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe . mm dia.mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.19/20 mm dia 2 mm thick | m | 87.23 | 87.23 | 130.0 | False | None | None | False | None | False | 11339.9 | 0 | 3444834 | 122318 | None | V6 S1.3.1 | Supplying heavy gauge PVC Conduit Pipe . dia . mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary. 19/20 mm dia 2mm thick | m | 89.87 | 89.87 | 230.0 | False | None | None | False | None | False | 20670.1 | 0 | 3444835 | 122318 | None | V6 S1.3.2 | Supplying heavy gauge PVC Conduit Pipe . dia . mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary.25 mm dia | m | 104.41 | 104.41 | 200.0 | False | None | None | False | None | False | 20882.0 | 0 | 3444836 | 122318 | None | V6 S2.3.2 | WIRING FOR Lighting/Power Circuits. Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 1.5 Sq.mm | m | 34.36 | 34.36 | 550.0 | False | None | None | False | None | False | 18898.0 | 0 | 3444837 | 122318 | None | V6 S2.3.3 | WIRING FOR Lighting/Power Circuits
Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.2,5 sq.mm
| m | 55.51 | 55.51 | 350.0 | False | None | None | False | None | False | 19428.5 | 0 | 3444838 | 122318 | None | V6 S2.3.4 | WIRING FOR Lighting/Power Circuits.Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.4 sq.mm
| m | 83.26 | 83.26 | 100.0 | False | None | None | False | None | False | 8326.0 | 0 | 3444839 | 122318 | None | V6 S2.3.5 | WIRING FOR Lighting/Power Circuits. Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.6sq.mm
| m | 121.59 | 121.59 | 50.0 | False | None | None | False | None | False | 6079.5 | 0 | 3444840 | 122318 | None | V6 S2.3.6 | WIRING FOR Lighting/Power Circuits. Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.10 sq.mm
| m | 220.71 | 220.71 | 50.0 | False | None | None | False | None | False | 11035.5 | 0 | 3444841 | 122318 | None | V6 S5.19.9 | Control System MCB DB. Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser.12 Way SP & N
| Each | 3078.01 | 3078.01 | 2.0 | False | None | None | False | None | False | 6156.02 | 0 | 3444842 | 122318 | None | V6 S5.18.1 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP
| Each | 548.46 | 548.46 | 18.0 | False | None | None | False | None | False | 9872.28 | 0 | 3444843 | 122318 | None | V6 S5.18.4 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 A DP
| Each | 976.66 | 976.66 | 6.0 | False | None | None | False | None | False | 5859.96 | 0 | 3444844 | 122318 | None | V6 S5.20.1 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole | Each | 5652.48 | 5652.48 | 2.0 | False | None | None | False | None | False | 11304.96 | 0 | 3444845 | 122318 | None | V6 S32.08 V-6 | CABLES.
"1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975"
25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)
| Km | 237681.83 | 237681.83 | 0.1 | False | None | None | False | None | False | 23768.183 | 0 | 3444846 | 122318 | None | V6 S21.05 V-6 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers asdirected by the departmental staff | Km | 27602.94 | 27602.94 | 0.1 | False | None | None | False | None | False | 2760.294 | 0 | 3444847 | 122318 | None | 11.1.4 ( V-5) | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990
with latest amendments complete with GI fittings (excluding the cost
of fittings) with cuts and threads wherever necessary, including testing
for water tightness, with all lead and commissioning. (contractor will
make his own arrangements for procuring water for testing) For:Heavy
Duty GI Pipe etc. complete Light Duty GI pipe of 32mm dia. | m | 441.41 | 441.41 | 7.0 | False | None | None | False | None | False | 3089.87 | 0 | 3444848 | 122318 | None | V6 S12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should befilled with equal proportion of salt and charcoal 150 mm all-round thepipe to complete depth. The connection from the pipe to the conduitetc., is to be established through GI wire of size as per lSI specification.7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nutsetc., the pipe shall have 16 through holes of 12 mm dia | No | 4638.82 | 4638.82 | 2.0 | False | None | None | False | None | False | 9277.64 | 0 | 3444849 | 122318 | None | V6 S12.58.2 | GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip | m | 108.37 | 108.37 | 18.0 | False | None | None | False | None | False | 1950.66 | 0 | 3444850 | 122318 | None | V6 S8.1 | Supplying and drawing UTP-CAT 6E LAN cable | m | 50.22 | 50.22 | 45.0 | False | None | None | False | None | False | 2259.9 | 0 | 3444851 | 122318 | None | V6 S5.42.2 | L.T.PANEL. Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete. 16SWG
| Sq CM | 0.57 | 0.57 | 42000.0 | False | None | None | False | None | False | 23940.0 | 0 | 3444852 | 122318 | None | V6 S5.40.1 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips
| m | 3257.74 | 3257.74 | 3.0 | False | None | None | False | None | False | 9773.22 | 0 | 3444853 | 122318 | None | V6 S5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm
| m | 403.09 | 403.09 | 3.0 | False | None | None | False | None | False | 1209.27 | 0 | 3444854 | 122318 | None | V6 S5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs). FOUR POLE 100Amps 25kA
| Each | 11216.42 | 11216.42 | 1.0 | False | None | None | False | None | False | 11216.42 | 0 | 3444855 | 122318 | None | V6 S5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN
| Each | 4081.1 | 4081.1 | 5.0 | False | None | None | False | None | False | 20405.5 | 0 | 3444856 | 122318 | None | V6 S5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 12310.7 | 12310.7 | 1.0 | False | None | None | False | None | False | 12310.7 | 0 | 3444857 | 122318 | None | V6 S5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | Each | 680.62 | 680.62 | 3.0 | False | None | None | False | None | False | 2041.86 | 0 | 3444858 | 122318 | None | V6 S5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound | Each | 742.74 | 742.74 | 3.0 | False | None | None | False | None | False | 2228.22 | 0 |
|
|
---|