createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720004692347
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1230.00
emd49000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose01-08-2024 16:00:00
tenderQueryClose26-07-2024 16:00:00
technicalBidOpen02-08-2024 16:10:00
publishedDate20-07-2024 17:27:44
publishedByPostEWHFWD_EE_EEOFF_MYS
publishedByUserKPE12441 - H SRINIVASAGOWDA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonManasa
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9449843319
tenderSupplierListNone
tenderSchedule
createdTs1720004692372
version5
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT406
titleCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH BANTWAL IN DAKSHINA KANNADA DISTRICT.(SECOND FLOOR)
descriptionCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH BANTWAL IN DAKSHINA KANNADA DISTRICT.
categoryWORKS
categoryTextWorks
ecv4917641.11
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3523
locationNameEWHFWD Executive Engineer Office Mysore
provisionalAmount5000000.0
groupOverheadTotal0.0
fileNumberKHSDRP/AEEMNG/BPHU/15TH-FC/DKBANTWAL
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17200046920001NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH BANTWAL IN DAKSHINA KANNADA DISTRICT.(CIVIL WORKS) (SECOND FLOOR)4308044.94
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3443911122292NoneV1P18S2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification)t120590.9120590.95.87FalseNoneNoneFalseNoneFalse707868.5830
3443912122292NoneV1P16S2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns including Centring and form works . .Cum15193.6715193.676.19FalseNoneNoneFalseNoneFalse94048.81730
3443913122292NoneV1P16S2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Chejjas including Centring and form works .Cum12959.3112959.312.59FalseNoneNoneFalseNoneFalse33564.61290
3443914122292NoneV1P16S2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintles and Beams including Centring and form works .Cum14299.9214299.9214.31FalseNoneNoneFalseNoneFalse204631.85520
3443915122292NoneV1P16S2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Roof slab including Centring and form works .Cum13406.1813406.1833.01FalseNoneNoneFalseNoneFalse442538.00180
3443916122292NoneV2P9S5.7Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples For super structure in CM 1:6.Cum9105.969105.9651.6FalseNoneNoneFalseNoneFalse469867.5360
3443917122292NoneV2P17S6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1488.231488.23221.1FalseNoneNoneFalseNoneFalse329047.6530
3443918122292NoneV2P109S12.86Providing and fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8 2.0mm Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made)Sqm7265.897265.8936.45FalseNoneNoneFalseNoneFalse264841.69050
3443919122292NoneV2P109S12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7709.47709.41.62FalseNoneNoneFalseNoneFalse12489.2280
3443920122292NoneV2P86S11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etcKgs246.69246.69685.26FalseNoneNoneFalseNoneFalse169046.78940
3443921122292NoneV2P100S12.13.1Providing sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as specifications.Cum133205.78133205.780.55FalseNoneNoneFalseNoneFalse73263.1790
3443922122292NoneV2P105S12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick Both side commercial.Sqm4478.164478.1630.7FalseNoneNoneFalseNoneFalse137479.5120
3443923122292NoneV2P111 S12.93.2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately).Size 62 x 125mmm1029.91029.920.4FalseNoneNoneFalseNoneFalse21009.960
3443924122292NoneV2P112S12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thicknessSqm4697.894697.897.5FalseNoneNoneFalseNoneFalse35234.1750
3443925122292NoneV2P105S12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1369.61369.611.0FalseNoneNoneFalseNoneFalse15065.60
3443926122292NoneV2P69S10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos80.8880.8811.0FalseNoneNoneFalseNoneFalse889.680
3443927122292NoneV2P105S12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1501.711501.7111.0FalseNoneNoneFalseNoneFalse16518.810
3443928122292NoneV2P105S12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1418.131418.1311.0FalseNoneNoneFalseNoneFalse15599.430
3443929122292NoneV2P105S12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. CompleteNos1334.551334.5511.0FalseNoneNoneFalseNoneFalse14680.050
3443930122292NoneV2P105S12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos319.48319.4822.0FalseNoneNoneFalseNoneFalse7028.560
3443931122292NoneV2P105S12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. CompleteNos175.24175.2422.0FalseNoneNoneFalseNoneFalse3855.280
3443932122292NoneV2P105S12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos74.1474.1411.0FalseNoneNoneFalseNoneFalse815.540
3443933122292NoneV2P107S12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos370.71370.7133.0FalseNoneNoneFalseNoneFalse12233.430
3443934122292NoneV2PA-25S447Providing & Fixing of honnewood beeding 100mm wide.Rmtr33.733.765.6FalseNoneNoneFalseNoneFalse2210.720
3443935122292NoneV2P150S15.7Water proofing works.Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydrostatic pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)Sqm829.04829.049.72FalseNoneNoneFalseNoneFalse8058.26880
3443936122292NoneV2P60S9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1543.51543.5192.88FalseNoneNoneFalseNoneFalse297710.280
3443937122292NoneV2P60S9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeSqm1198.41198.49.7FalseNoneNoneFalseNoneFalse11624.480
3443938122292NoneV2P71S10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade completeSqm1490.921490.9252.9FalseNoneNoneFalseNoneFalse78869.6680
3443939122292NoneV2P63S9.28Providing and laying flooring and steps machine cut granite slabs 40mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specificationsSqm5768.235768.2315.9FalseNoneNoneFalseNoneFalse91714.8570
3443940122292NoneV2P43S8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in chargeSqm284.43284.43190.5FalseNoneNoneFalseNoneFalse54183.9150
3443941122292NoneV2P41S8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding ,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge ( Inside)Sqm376.1376.1596.2FalseNoneNoneFalseNoneFalse224230.820
3443942122292NoneV2P42S8.9Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) finished rough to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( outside)Sqm518.99518.99256.4FalseNoneNoneFalseNoneFalse133069.0360
3443943122292NoneV2P43S8.16.1Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )Plaster meshRmtr45.8345.83143.61FalseNoneNoneFalseNoneFalse6581.64630
3443944122292NoneV2P 47S8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-changeSqm71.4571.4540.6FalseNoneNoneFalseNoneFalse2900.870
3443945122292NoneV2P 48S8.40Painting with synthetic enamel paint of approved brand and manu facture of required colour to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm155.02155.0240.6FalseNoneNoneFalseNoneFalse6293.8120
3443946122292NoneV2P 50S8.51Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm134.8134.8786.7FalseNoneNoneFalseNoneFalse106047.160
3443947122292NoneV2P 48S8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm171.2171.2786.7FalseNoneNoneFalseNoneFalse134683.040
3443948122292NoneV2P46S8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm234.56234.56256.4FalseNoneNoneFalseNoneFalse60141.1840
3443949122292NoneV2P 47S8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm67.467.436.45FalseNoneNoneFalseNoneFalse2456.730
3443950122292NoneV2P 48S8.40Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm155.02155.0236.45FalseNoneNoneFalseNoneFalse5650.4790
17200046920000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH BANTWAL IN DAKSHINA KANNADA DISTRICT.(WATER SUPPLY AND SANITARY WORKS)(SECOND FLOOR)228835.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3443951122293NoneP.No.122 I.No.13.32.3 of Vol.2 of SR 2023-24)Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc.25 mm Diam643.01643.0125.0FalseNoneNoneFalseNoneFalse16075.250
3443952122293NoneP.No.122 I.No.13.32.4 of Vol.2 of SR 2023-24Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per directions of Engineer in charge.Concealed work,including cutting chases and making good the walls etc. 32 mm Diam750.85750.8520.0FalseNoneNoneFalseNoneFalse15017.00
3443953122293NoneP.No.119 I.No.13.12 of Vol.2 of SR 2023-24)Providing and fixing brass bib cock of approved quality :20 mm nominal boreNos856.0856.04.0FalseNoneNoneFalseNoneFalse3424.00
3443954122293NoneP.No.117 I.No.13.4.1 of Vol.2 of SR 2023-24Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal boreNos740.07740.072.0FalseNoneNoneFalseNoneFalse1480.140
3443955122293NoneP.No.117 I.No.13.4.2 of Vol2 of SR 2023-24Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal boreNos806.12806.121.0FalseNoneNoneFalseNoneFalse806.120
3443956122293NoneP.No.132 I.No.14.7.2 of Vol.2 of SR 2023-24)Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever eequire:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3452.313452.314.0FalseNoneNoneFalseNoneFalse13809.240
3443957122293NoneP.No.132 I.No.14.5.1 of Vol.2 of SR 2023-24)Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach11649.6911649.692.0FalseNoneNoneFalseNoneFalse23299.380
3443958122293NoneP.No.132 I.No.14.7.3 of Vol.2 of SR 2023-24)White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar tapsEach3863.463863.464.0FalseNoneNoneFalseNoneFalse15453.840
3443959122293NoneP.No.133 I.No.14.9.1 of Vol.2 of SR 2023-24)Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mmEach4018.484018.481.0FalseNoneNoneFalseNoneFalse4018.480
3443960122293NoneP.No.136 I.No.14.27.2 of Vol.2 of SR 2023-24)Providing and fixing white vitreous china laboratory sink including making all connections including cost of fittings Size 600x450x200 mmEach4479.514479.515.0FalseNoneNoneFalseNoneFalse22397.550
3443961122293NoneP.No.136 I.No.14.28.2.2 of Vol.2 of SR 2023-24Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete:Semi rigid pipe:40mm diaEach124.02124.027.0FalseNoneNoneFalseNoneFalse868.140
3443962122293NoneP.No.137 I.No.14.40.2 of Vol.2 of SR 2023-24)Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gEach668.62668.627.0FalseNoneNoneFalseNoneFalse4680.340
3443963122293NoneP.No.136 I.No.14.32.2 of Vol.2 of SR 2023-24)Providing and fixing 453x357mm dia rectangular shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backing .Each1372.31372.34.0FalseNoneNoneFalseNoneFalse5489.20
3443964122293NoneP.No.131 I.No.14.3.1 of Vol.2 of SR 2023-24)Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lidEach8057.198057.194.0FalseNoneNoneFalseNoneFalse32228.760
3443965122293NoneVOL2I.NO:13.42P124Providing and fixing trap of self ceansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors:*100mm inlet and 100mm outlet.* Sand cast iron S&S as per IS:1729.Each1543.51543.54.0FalseNoneNoneFalseNoneFalse6174.00
3443966122293NoneVOL2I.NO:13.48P125Providing and fixingon wall face unplasticised Rigid PVC rain water pipes confirming to IS:13592 Type A,including jointing with seal ring confirming to IS:5382,leaving 10mm gap for the thermal expansion,(i) Single socketed pipes 100mm diameterRmtr392.28392.2840.0FalseNoneNoneFalseNoneFalse15691.20
3443967122293NoneVOL2I.NO:13.36P123Cutting holes upto 30X30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks.Each435.41435.418.0FalseNoneNoneFalseNoneFalse3483.280
3443968122293NoneVOL2I.NO:13.37P123Cutting holes upto 15X15cm in RCC floors and roofs for passing drain pipe etc.,and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size)including finishing complete so as to make it leak proof.Each421.93421.938.0FalseNoneNoneFalseNoneFalse3375.440
3443969122293NonePage no.120, item no.13.22.2 of Vol 2 SR2023-24Providing and fixing PTMT grating of approved quality and colour, Rectangular type with openable circular lidEach272.3272.37.0FalseNoneNoneFalseNoneFalse1906.10
3443970122293NonePage no.120, item no.13.23.1 of Vol 2 SRProviding and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D.plastic ball 15 mm nominal bore, 105 mm long, weighing not less than 138 gNo276.35276.351.0FalseNoneNoneFalseNoneFalse276.350
3443971122293NonePage no.119, item no.13.15 of Vol 2 SR2023-24Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931No977.32977.321.0FalseNoneNoneFalseNoneFalse977.320
3443972122293NonePage no.119, item no.13.16 of Vol 2 SR2023-24Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos835.78835.788.0FalseNoneNoneFalseNoneFalse6686.240
3443973122293NoneVOL2I.NO:13.34P123Providing and placing on terrace(at all floor levels), polyethylene water storage tank,IS:120701 marked,with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tankLtr12.1312.132000.0FalseNoneNoneFalseNoneFalse24260.00
3443974122293NoneVOL2 I.NO:13.39 P124Providing and fixing square mouth S.W.gully trap class SP-1 complete with C.I.grating,brick masonry camber 150X 100 mm size P type with non modular bcommon burnt clay bricks of designation 3.5 & with water tight.C.I cover with frame of 300X300 mm size (inside)the weight of the cover to be not less than 4.50kg and frame to be not less than 2.70kg as per standard designEach3479.273479.272.0FalseNoneNoneFalseNoneFalse6958.540
17200046920000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT GH BANTWAL IN DAKSHINA KANNADA DISTRICT- (ELECTRIFICATION WORKS )380760.26
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3443975122294NoneV6S2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH. Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.Short point upto 3 mts from tapping point to out let via switchPoint355.51355.5122.0FalseNoneNoneFalseNoneFalse7821.220
3443976122294NoneV6S2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH.Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.Medium point above 3 mts upto 6mts from tapping point to outlet via switchPoint500.89500.8916.0FalseNoneNoneFalseNoneFalse8014.240
3443977122294NoneV6S2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH.Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2(Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: andlatest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shallbe terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.Long point above 6 mts upto 10 mts from tapping point to outlet via switchPoint733.49733.4915.0FalseNoneNoneFalseNoneFalse11002.350
3443978122294NoneV6S3.4.2Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 3 wayEach210.13210.1313.0FalseNoneNoneFalseNoneFalse2731.690
3443979122294NoneV6S3.4.3Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 4 - 5 wayEach233.92233.9212.0FalseNoneNoneFalseNoneFalse2807.040
3443980122294NoneV6S3.4.4Supplying and flush mounting powder coated, Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone cc wall. 6 way ,Each290.75290.756.0FalseNoneNoneFalseNoneFalse1744.50
3443981122294NoneV6S3.4.5Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 8 wayEach344.94344.9419.0FalseNoneNoneFalseNoneFalse6553.860
3443982122294NoneV6 S3.4.7Supplying and flush mounting powder coated/ Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall. 16 wayEach479.74479.747.0FalseNoneNoneFalseNoneFalse3358.180
3443983122294NoneV6 S3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 3 moduleEach212.78212.7813.0FalseNoneNoneFalseNoneFalse2766.140
3443984122294NoneV6 S3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 4 moduleEach231.28231.2812.0FalseNoneNoneFalseNoneFalse2775.360
3443985122294NoneV6 S3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 6 moduleEach309.25309.256.0FalseNoneNoneFalseNoneFalse1855.50
3443986122294NoneV6 S3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 8 moduleEach375.33375.3319.0FalseNoneNoneFalseNoneFalse7131.270
3443987122294NoneV6 S3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box. 16 moduleEach524.68524.687.0FalseNoneNoneFalseNoneFalse3672.760
3443988122294NoneV6 S3.6.1Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6 amps one way switchEach134.8134.884.0FalseNoneNoneFalseNoneFalse11323.20
3443989122294NoneV6 S3.6.3Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6 Amps 3 way socketsEach225.99225.9916.0FalseNoneNoneFalseNoneFalse3615.840
3443990122294NoneV6 S3.6.4Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. stepped fan Regulator'sEach471.81471.8112.0FalseNoneNoneFalseNoneFalse5661.720
3443991122294NoneV6 S3.6.7Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 16 amps one way switchEach237.89237.8934.0FalseNoneNoneFalseNoneFalse8088.260
3443992122294NoneV6 S3.6.10Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal socketsEach311.9311.934.0FalseNoneNoneFalseNoneFalse10604.60
3443993122294NoneV6 S3.6.9Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293. 32A DP SwitchEach430.84430.843.0FalseNoneNoneFalseNoneFalse1292.520
3443994122294NoneV6 S1.13Supply and fixing one metal Fan box with round hookEach154.63154.6312.0FalseNoneNoneFalseNoneFalse1855.560
3443995122294NoneV6 S1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe . mm dia.mm thickconfirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.19/20 mm dia 2 mm thickm87.2387.23130.0FalseNoneNoneFalseNoneFalse11339.90
3443996122294NoneV6 S1.3.1Supplying heavy gauge PVC Conduit Pipe . dia . mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary. 19/20 mm dia 2mm thickm89.8789.87230.0FalseNoneNoneFalseNoneFalse20670.10
3443997122294NoneV6 S1.3.2Supplying heavy gauge PVC Conduit Pipe . dia . mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing Uor J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduitwherever necessary.25 mm diam104.41104.41200.0FalseNoneNoneFalseNoneFalse20882.00
3443998122294NoneV6 S2.3.2WIRING FOR Lighting/Power Circuits. Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments. 1.5 Sq.mmm34.3634.36550.0FalseNoneNoneFalseNoneFalse18898.00
3443999122294NoneV6 S2.3.3WIRING FOR Lighting/Power Circuits Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.2,5 sq.mm m55.5155.51350.0FalseNoneNoneFalseNoneFalse19428.50
3444000122294NoneV6 S2.3.4WIRING FOR Lighting/Power Circuits.Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.4 sq.mm m83.2683.26100.0FalseNoneNoneFalseNoneFalse8326.00
3444001122294NoneV6 S2.3.5WIRING FOR Lighting/Power Circuits. Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.6sq.mm m121.59121.5950.0FalseNoneNoneFalseNoneFalse6079.50
3444002122294NoneV6 S2.3.6WIRING FOR Lighting/Power Circuits. Wiring for lighting/power circuit using one of FRLS PVCinsulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system ofwiring with specified IS-694:confirming to latest amendments.10 sq.mm m220.71220.7150.0FalseNoneNoneFalseNoneFalse11035.50
3444003122294NoneV6 S5.19.9Control System MCB DB. Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting. Made out of 14SWG MS enclouser.12 Way SP & N Each3078.013078.012.0FalseNoneNoneFalseNoneFalse6156.020
3444004122294NoneV6 S5.18.1Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP Each548.46548.4618.0FalseNoneNoneFalseNoneFalse9872.280
3444005122294NoneV6 S5.18.4Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 A DP Each976.66976.666.0FalseNoneNoneFalseNoneFalse5859.960
3444006122294NoneV6 S5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 poleEach5652.485652.482.0FalseNoneNoneFalseNoneFalse11304.960
3444007122294NoneV6 S32.08 V-6CABLES. "1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975" 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) Km237681.83237681.830.1FalseNoneNoneFalseNoneFalse23768.1830
3444008122294NoneV6 S21.05 V-6Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers asdirected by the departmental staffKm27602.9427602.940.1FalseNoneNoneFalseNoneFalse2760.2940
3444009122294None11.1.4 ( V-5)Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete Light Duty GI pipe of 32mm dia.m441.41441.417.0FalseNoneNoneFalseNoneFalse3089.870
3444010122294NoneV6 S12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should befilled with equal proportion of salt and charcoal 150 mm all-round thepipe to complete depth. The connection from the pipe to the conduitetc., is to be established through GI wire of size as per lSI specification.7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nutsetc., the pipe shall have 16 through holes of 12 mm diaNo4638.824638.822.0FalseNoneNoneFalseNoneFalse9277.640
3444011122294NoneV6 S12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI stripm108.37108.3718.0FalseNoneNoneFalseNoneFalse1950.660
3444012122294NoneV6 S8.1Supplying and drawing UTP-CAT 6E LAN cablem50.2250.2245.0FalseNoneNoneFalseNoneFalse2259.90
3444013122294NoneV6 S5.42.2L.T.PANEL. Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete. 16SWG Sq CM0.570.5742000.0FalseNoneNoneFalseNoneFalse23940.00
3444014122294NoneV6 S5.40.1Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolici FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips m3257.743257.743.0FalseNoneNoneFalseNoneFalse9773.220
3444015122294NoneV6 S5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm m403.09403.093.0FalseNoneNoneFalseNoneFalse1209.270
3444016122294NoneV6 S5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs). FOUR POLE 100Amps 25kA Each11216.4211216.421.0FalseNoneNoneFalseNoneFalse11216.420
3444017122294NoneV6 S5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN Each4081.14081.15.0FalseNoneNoneFalseNoneFalse20405.50
3444018122294NoneV6 S5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach12310.712310.71.0FalseNoneNoneFalseNoneFalse12310.70
3444019122294NoneV6 S5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CEach680.62680.623.0FalseNoneNoneFalseNoneFalse2041.860
3444020122294NoneV6 S5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach742.74742.743.0FalseNoneNoneFalseNoneFalse2228.220
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17200046950000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17200046950001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government / Government of India /Union TerritoryNone
17200046950001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPPP portal due to internet connectivity issues and technical glitches at bidders end.None
17200046950000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17200046950000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17200049130000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17200049520000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17200049790000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17200049900000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17200050030000NoneNoneELIGIBILITYMaterials like, steel, cement etc., required for the work shall be procured by the tenderer themselves and should got tested positive by the quality control authority before use on the workNone
17200050160000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17200051100000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17200051260000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (Section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17200051420000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17200051560000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within a weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as non responsiveNone
17200051780000NoneNoneELIGIBILITYAdditional Clause: In the case of the death of a contractor after executing the agreement / commencement of the work, his legal heir, if an eligible registered contractor and willing, can execute and complete the work at the accepted tender rates irrespective of the cost of the workNone
17200051940000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17200052050000NoneNoneELIGIBILITYGST registration certificate should be enclosedNone
17200052440000NoneNoneELIGIBILITYThe rates quoted shall be inclusive of GST.None
17200052490000NoneNoneELIGIBILITYThe eligible tenderers belonging to Schedule Tribe should upload Schedule Tribe certificate issued by Tahasildar /competent authority and the certificate should be duly attested by Gazetted OfficerNone
17202461390000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least any construction work of value not less than Rs. 12.29 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) To qualify for award of this contract The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works in the last five years i.e (2019-20 to 2023-24) totaling Rs. 1.90 Lakhs in any one year Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works in the last five years i.e (2019-20 to 2023-24)totaling Rs. 1.14 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least One financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 49.17 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate in the last five years 2019-20 to 2023-24 issued by charted accountantTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
KPWD Class-III and above Registration Certificate.TrueTechnical Bid
Work done certificate to be uploaded, which has to be issued not below the rank of Executive EngineerTrueTechnical Bid
The eligible tenderers belonging to Schedule Tribe should upload Schedule Tribe certificate issued by Tahasildar /competent authority and the certificate should be duly attested by Gazetted OfficerTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone