createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719642199259
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1250.00
emd50000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-08-2024 16:00:00
tenderQueryClose03-08-2024 16:00:00
technicalBidOpen06-08-2024 16:00:05
publishedDate22-07-2024 16:36:55
publishedByPostEWHFWD_EE_EEOFF_MYS
publishedByUserKPE12441 - H SRINIVASAGOWDA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAzra
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9449843313
tenderSupplierListNone
tenderSchedule
createdTs1719642199285
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT512
titleCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TLH YALANDURU IN CHAMARAJANAGAR DISTRICT.
descriptionCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TLH YALANDURU IN CHAMARAJANAGAR DISTRICT.
categoryWORKS
categoryTextWorks
ecv4968514.74
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3523
locationNameEWHFWD Executive Engineer Office Mysore
provisionalAmount5000000.0
groupOverheadTotal0.0
fileNumberHFW/AEE/MYS/BPHUYalandur
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17196421990000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TLH YALANDURU IN CHAMARAJANAGAR DISTRICT. (Civil Works)4167301.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3407315120348NoneI-2.5A P-9 V-3Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle.Sqm477.65477.652.17FalseNoneNoneFalseNoneFalse1036.50050
3407316120348NoneI-1.12 P-8 V-1Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum115.46115.4665.25FalseNoneNoneFalseNoneFalse7533.7650
3407317120348NoneI-1.14.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum123.97123.9799.14FalseNoneNoneFalseNoneFalse12290.38580
3407318120348NoneI-1.15.1 P-8 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.Cum441.19441.1910.25FalseNoneNoneFalseNoneFalse4522.19750
3407319120348NoneI-1.1B P-5 V-3Loading and Unloading of Stone Boulder/Stone aggregates/Sand/ Kankar/Moorum. (Tipper 10 m3 )Cum144.63144.6360.25FalseNoneNoneFalseNoneFalse8713.95750
3407320120348NoneI-1.9 P-34 V-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum323.3323.399.91FalseNoneNoneFalseNoneFalse32300.9030
3407321120348NoneI-1.8 P-33 V-1Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials,usage & all other appurtenaces required to complete the work.Cum576.1576.164.91FalseNoneNoneFalseNoneFalse37394.6510
3407322120348NoneI-2.1.3 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates.Cum7279.037279.0329.86FalseNoneNoneFalseNoneFalse217351.83580
3407323120348NoneI-2.2.3 P-15 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. FOOTINGSCum8316.848316.8418.12FalseNoneNoneFalseNoneFalse150701.14080
3407324120348NoneI-2.2.3 P-15 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PEDESTALSCum8316.848316.842.59FalseNoneNoneFalseNoneFalse21540.61560
3407325120348NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNSCum13698.7713698.779.0FalseNoneNoneFalseNoneFalse123288.930
3407326120348NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PLINTH BEAM, RCC SLABCum12087.1512087.1537.61FalseNoneNoneFalseNoneFalse454597.71150
3407327120348NoneI-2.5.1 P-16 V-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure worksof bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC BEAMS, LINTELSCum12892.9612892.9613.17FalseNoneNoneFalseNoneFalse169800.28320
3407328120348NoneI-2.1.4 P-15 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates.Cum7556.147556.143.35FalseNoneNoneFalseNoneFalse25313.0690
3407329120348NoneI-15.4 P-135 V-3Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/ EpoxyNo.247.94247.9410.0FalseNoneNoneFalseNoneFalse2479.40
3407330120348NoneI-8.16a P-55 V-2Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.Sqm1504.671504.674.5FalseNoneNoneFalseNoneFalse6771.0150
3407331120348NoneI-2.11 P-84 V-2Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) BuildingsTonne108726.04108726.045.95FalseNoneNoneFalseNoneFalse646919.9380
3407332120348NoneI-4.21 P-15 S.R 2018-19KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS. (P. No. 14/ I.No. 4.21 of PWD 2018-19)Rmtr40.1140.1154.0FalseNoneNoneFalseNoneFalse2165.940
3407333120348NoneI-5.4 P-9 V-2Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7765.197765.1920.82FalseNoneNoneFalseNoneFalse161671.25580
3407334120348NoneI-6.32 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1592.171592.17164.48FalseNoneNoneFalseNoneFalse261880.12160
3407335120348NoneI-6.34 P-17 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1341.81341.867.33FalseNoneNoneFalseNoneFalse90343.3940
3407336120348NoneI-12.13.1 P-100 V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum120099.75120099.750.99FalseNoneNoneFalseNoneFalse118898.75250
3407337120348NoneI-12.51 P-104 V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1234.851234.8512.0FalseNoneNoneFalseNoneFalse14818.20
3407338120348NoneI-12.60 P-105 V-2Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1278.61278.612.0FalseNoneNoneFalseNoneFalse15343.20
3407339120348NoneI-12.61 P-105 V-2Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1203.251203.2512.0FalseNoneNoneFalseNoneFalse14439.00
3407340120348NoneI-12.62 P-105 V-2Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos288.05288.0524.0FalseNoneNoneFalseNoneFalse6913.20
3407341120348NoneI-12.63 P-107 V-2Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos158.0158.024.0FalseNoneNoneFalseNoneFalse3792.00
3407342120348NoneI-12.64 P-107 V-2Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos66.8566.8512.0FalseNoneNoneFalseNoneFalse802.20
3407343120348NoneI-12.75.1 P-107 V-2Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos334.24334.2424.0FalseNoneNoneFalseNoneFalse8021.760
3407344120348NoneI-10.6.3 P-69 V-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos72.9272.9272.0FalseNoneNoneFalseNoneFalse5250.240
3407345120348NoneI-15.37 P-117 S.R 2018-19KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along exposed corners of walls, coloumns, lintels including cost of materials, labour for fixing complete . (length of mesh be measured for payment)Rmtr34.0334.0377.6FalseNoneNoneFalseNoneFalse2640.7280
3407346120348NoneI-12.57.6 P-105 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4037.564037.5628.56FalseNoneNoneFalseNoneFalse115312.71360
3407347120348NoneI-12.90 P-110 V-2Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).Sqm8184.58184.527.0FalseNoneNoneFalseNoneFalse220981.50
3407348120348NoneI-12.85 P-109 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).Sqm6950.876950.871.44FalseNoneNoneFalseNoneFalse10009.25280
3407349120348NoneI-11.34A P-86 V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg204.19204.19597.24FalseNoneNoneFalseNoneFalse121950.43560
3407350120348NoneI-12.96 P-112 V-2Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.m781.5781.519.8FalseNoneNoneFalseNoneFalse15473.70
3407351120348NoneI-12.97.1 P-112 V-2Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 30 mm thickness.Sqm3894.143894.146.3FalseNoneNoneFalseNoneFalse24533.0820
3407352120348NoneI-12.59 P-105 V-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1353.961353.9612.0FalseNoneNoneFalseNoneFalse16247.520
3407353120348NoneI-11.25.2 P-84 V-2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- ChargeKgs165.29165.29241.92FalseNoneNoneFalseNoneFalse39986.95680
3407354120348NoneI-11.35.1.1 P-86 V-2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specificationsKg549.36549.3654.0FalseNoneNoneFalseNoneFalse29665.440
3407355120348NoneI-11.37.1 P-89 V-2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm1200.821200.827.2FalseNoneNoneFalseNoneFalse8645.9040
3407356120348NoneI-8.10 P-41 V-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm320.56320.56142.71FalseNoneNoneFalseNoneFalse45747.11760
3407357120348NoneI-8.5.2 P-42 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)Sqm530.22530.22317.43FalseNoneNoneFalseNoneFalse168307.73460
3407358120348NoneI-8.51 P-50 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm121.54121.54294.25FalseNoneNoneFalseNoneFalse35763.1450
3407359120348NoneI-8.8 P-42 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm563.64563.64222.9FalseNoneNoneFalseNoneFalse125635.3560
3407360120348NoneI-8.16.2 P43 V-2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide.Rmtr46.1946.19375.0FalseNoneNoneFalseNoneFalse17321.250
3407361120348NoneI-10.5.2 P-69 S.R 2018-19Bore Packing : filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulation on the bore. including all labour charges tools and equipments, all complete as per the manufacturer.Sqm262.53262.5310.0FalseNoneNoneFalseNoneFalse2625.30
3407362120348NoneI-8.79 P-54 V-2Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m63.263.2256.0FalseNoneNoneFalseNoneFalse16179.20
3407363120348NoneI-9.21.2 P-62 V-2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).).Size of Tile 600x600 mm.Sqm1504.671504.67158.92FalseNoneNoneFalseNoneFalse239122.15640
3407364120348NoneI-8.2.1 P-41 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm358.54358.5442.84FalseNoneNoneFalseNoneFalse15359.85360
3407365120348NoneI-9.11 P-60 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.Sqm926.13926.138.34FalseNoneNoneFalseNoneFalse7723.92420
3407366120348NoneI-9.39 P-65 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1260.371260.3742.84FalseNoneNoneFalseNoneFalse53994.25080
3407367120348NoneI-8.39 P-48 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm192.94192.94588.51FalseNoneNoneFalseNoneFalse113547.11940
3407368120348NoneI-8.31 P-46 V-2Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm270.43270.43222.9FalseNoneNoneFalseNoneFalse60278.8470
3407369120348NoneI-8.34.3 P-47 V-2Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm60.7760.7728.44FalseNoneNoneFalseNoneFalse1728.29880
3407370120348NoneI-8.40 P-48 V-2Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm139.77139.7728.44FalseNoneNoneFalseNoneFalse3975.05880
3407371120348NoneI-8.34.1 P-47 V-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm64.4264.4268.54FalseNoneNoneFalseNoneFalse4415.34680
3407372120348NoneI-8.47 P-49 V-2Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm164.08164.0868.54FalseNoneNoneFalseNoneFalse11246.04320
3407373120348NoneI-10.1.7 P-113 V-5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3m499.53499.5324.0FalseNoneNoneFalseNoneFalse11988.720
17196421990000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TLH YALANDURU IN CHAMARAJANAGAR DISTRICT. (Water Supply & Sanitary Works)321976.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3407374120349NoneI-14.28.2.2 P-136 V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40mm dia pipesEach111.82111.828.0FalseNoneNoneFalseNoneFalse894.560
3407375120349NoneI-16.7.4 P-191 V-5Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipesm168.94168.9415.0FalseNoneNoneFalseNoneFalse2534.10
3407376120349NoneI-10.1.5 P-113 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 75mm dia., 6 kg/sqcm & class 3m267.39267.3940.0FalseNoneNoneFalseNoneFalse10695.60
3407377120349NoneI-10.1.7 P-113 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for : PVC pipes 110mm dia., 6 kg/sqcm & class 3m499.53499.5335.0FalseNoneNoneFalseNoneFalse17483.550
3407378120349NoneI-13.47 P-125 V-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameterm239.43239.4320.0FalseNoneNoneFalseNoneFalse4788.60
3407379120349NoneI-14.31 P-136 V-2Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1482.791482.794.0FalseNoneNoneFalseNoneFalse5931.160
3407380120349NoneI-14.44 P-138 V-2Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.Each13641.6513641.654.0FalseNoneNoneFalseNoneFalse54566.60
3407381120349NoneI-14.11.2 P-134 V-2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mmNos.6176.666176.662.0FalseNoneNoneFalseNoneFalse12353.320
3407382120349NoneI-166 P-A16 V-2C.P. Brass stop cock (concealed) 15 mmNos.619.5619.54.0FalseNoneNoneFalseNoneFalse2478.00
3407383120349NoneI-14.7.1 P-124 V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar tapsEach3745.863745.864.0FalseNoneNoneFalseNoneFalse14983.440
3407384120349NoneI-13.32.1 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipesm375.56375.565.0FalseNoneNoneFalseNoneFalse1877.80
3407385120349NoneI-13.32.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipesm460.64460.6445.0FalseNoneNoneFalseNoneFalse20728.80
3407386120349NoneI-13.33.2 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 20 mm nominal dia Pipesm263.74263.7420.0FalseNoneNoneFalseNoneFalse5274.80
3407387120349NoneI-13.33.3 P-122 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm nominal dia Pipesm359.76359.7630.0FalseNoneNoneFalseNoneFalse10792.80
3407388120349NoneI-109 P-A15 V-2Brass full way valve with C.I. wheel (screwed end) 25 mm diaNos.442.5442.54.0FalseNoneNoneFalseNoneFalse1770.00
3407389120349NoneI-16.9 P-191 V-5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each6628.796628.792.0FalseNoneNoneFalseNoneFalse13257.580
3407390120349NoneI-12.112.2 P-90 S.R 2018-19Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). - 15cms x 10cmsEach330.4330.42.0FalseNoneNoneFalseNoneFalse660.80
3407391120349NoneI-13.34 P-123 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.l10.9410.941000.0FalseNoneNoneFalseNoneFalse10940.00
3407392120349NoneA.RProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards 10Cms X 7.5CmsNos.371.7371.76.0FalseNoneNoneFalseNoneFalse2230.20
3407393120349NoneA.RAir Vent Cowel 75mmNos.413.0413.01.0FalseNoneNoneFalseNoneFalse413.00
3407394120349NoneA.RAir Vent Cowel 110mmNos.590.0590.01.0FalseNoneNoneFalseNoneFalse590.00
3407395120349NoneA.RSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Nos.2183.02183.04.0FalseNoneNoneFalseNoneFalse8732.00
3407396120349NoneA.RSupply and fixing of GRP Disinfection Tank for LabNos.118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
17196421990000NoneNoneBuildingsCONSTRUCTION OF BLOCK LEVEL PUBLIC HEALTH UNIT AT TLH YALANDURU IN CHAMARAJANAGAR DISTRICT. (Electrical Works)479236.51
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3407397120350None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box.Point326.94326.9412.0FalseNoneNoneFalseNoneFalse3923.280
3407398120350None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint460.64460.6415.0FalseNoneNoneFalseNoneFalse6909.60
3407399120350None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint674.55674.5522.0FalseNoneNoneFalseNoneFalse14840.10
3407400120350None2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint822.83822.835.0FalseNoneNoneFalseNoneFalse4114.150
3407401120350None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 WayEach167.73167.7310.0FalseNoneNoneFalseNoneFalse1677.30
3407402120350None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5WayEach215.13215.133.0FalseNoneNoneFalseNoneFalse645.390
3407403120350None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6WayEach267.39267.392.0FalseNoneNoneFalseNoneFalse534.780
3407404120350None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 8 WayEach317.22317.223.0FalseNoneNoneFalseNoneFalse951.660
3407405120350None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12WayEach387.71387.7118.0FalseNoneNoneFalseNoneFalse6978.780
3407406120350None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleEach166.51166.5110.0FalseNoneNoneFalseNoneFalse1665.10
3407407120350None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach195.68195.683.0FalseNoneNoneFalseNoneFalse587.040
3407408120350None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach284.4284.42.0FalseNoneNoneFalseNoneFalse568.80
3407409120350None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleEach345.17345.173.0FalseNoneNoneFalseNoneFalse1035.510
3407410120350None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach418.1418.118.0FalseNoneNoneFalseNoneFalse7525.80
3407411120350None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach123.97123.97109.0FalseNoneNoneFalseNoneFalse13512.730
3407412120350None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach207.83207.8355.0FalseNoneNoneFalseNoneFalse11430.650
3407413120350None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two ModuleEach433.9433.912.0FalseNoneNoneFalseNoneFalse5206.80
3407414120350None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach218.77218.772.0FalseNoneNoneFalseNoneFalse437.540
3407415120350None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach396.22396.228.0FalseNoneNoneFalseNoneFalse3169.760
3407416120350None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach286.83286.8310.0FalseNoneNoneFalseNoneFalse2868.30
3407417120350NoneI-1.13Supplying And Fixing Metal Fan Box with Round HookNo142.2142.212.0FalseNoneNoneFalseNoneFalse1706.40
3407418120350None1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickm80.2280.22250.0FalseNoneNoneFalseNoneFalse20055.00
3407419120350None1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm94.894.8350.0FalseNoneNoneFalseNoneFalse33180.00
3407420120350None1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thickm125.19125.19100.0FalseNoneNoneFalseNoneFalse12519.00
3407421120350None1.3.1Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm82.6582.65200.0FalseNoneNoneFalseNoneFalse16530.00
3407422120350None1.3.2Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm96.0296.02100.0FalseNoneNoneFalseNoneFalse9602.00
3407423120350None1.3.3Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thickm120.32120.3250.0FalseNoneNoneFalseNoneFalse6016.00
3407424120350None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm31.631.6225.0FalseNoneNoneFalseNoneFalse7110.00
3407425120350None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm51.0551.05750.0FalseNoneNoneFalseNoneFalse38287.50
3407426120350None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm76.5776.57300.0FalseNoneNoneFalseNoneFalse22971.00
3407427120350None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmm111.82111.82200.0FalseNoneNoneFalseNoneFalse22364.00
3407428120350None5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure 12 Way SP & NEach2264.292264.292.0FalseNoneNoneFalseNoneFalse4528.580
3407429120350None5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & NEach4907.794907.791.0FalseNoneNoneFalseNoneFalse4907.790
3407430120350None5.20.8Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel boar 32-40 Amps 4 poleEach6255.666255.661.0FalseNoneNoneFalseNoneFalse6255.660
3407431120350NoneI-32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 25 sqmmKm169605.42169605.420.05FalseNoneNoneFalseNoneFalse8480.2710
3407432120350NoneI-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 sqmm to 25 sqmmKm25384.8425384.840.05FalseNoneNoneFalseNoneFalse1269.2420
3407433120350NoneI-29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard SoilCum472.79472.7950.0FalseNoneNoneFalseNoneFalse23639.50
3407434120350NoneI-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No5172.745172.742.0FalseNoneNoneFalseNoneFalse10345.480
3407435120350None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripm99.6699.6620.0FalseNoneNoneFalseNoneFalse1993.20
3407436120350None11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach838.63838.6327.0FalseNoneNoneFalseNoneFalse22643.010
3407437120350None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1075.631075.6310.0FalseNoneNoneFalseNoneFalse10756.30
3407438120350None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthEach1775.71775.71.0FalseNoneNoneFalseNoneFalse1775.70
3407439120350NoneI-13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each196.89196.891.0FalseNoneNoneFalseNoneFalse196.890
3407440120350None5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWGSq CM0.520.5240000.0FalseNoneNoneFalseNoneFalse20800.00
3407441120350None5.40.1Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100Amps 4x30x6mm Aluminum Stripsm2995.962995.963.0FalseNoneNoneFalseNoneFalse8987.880
3407442120350None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mmm370.7370.710.0FalseNoneNoneFalseNoneFalse3707.00
3407443120350None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint. 50x100x50x6mm C channelm918.84918.8410.0FalseNoneNoneFalseNoneFalse9188.40
3407444120350None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 kaEach10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
3407445120350None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach504.39504.393.0FalseNoneNoneFalseNoneFalse1513.170
3407446120350None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DPEach898.18898.182.0FalseNoneNoneFalseNoneFalse1796.360
3407447120350None5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPNEach3753.163753.161.0FalseNoneNoneFalseNoneFalse3753.160
3407448120350None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6Each409.59409.599.0FalseNoneNoneFalseNoneFalse3686.310
3407449120350None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone SocketEach189.6189.64.0FalseNoneNoneFalseNoneFalse758.40
3407450120350NoneI-8.1Supplying and drawing UTP-CAT 6E LAN cable.m46.1946.19225.0FalseNoneNoneFalseNoneFalse10392.750
3407451120350None8.10.1Supplying & fixing of I/O socket with back box. Single I/OEach595.55595.559.0FalseNoneNoneFalseNoneFalse5359.950
3407452120350None8.4.1Supplying & Fixing of switch mounting rack with power manager & Cable manager (85/11.4) 4U with 450mm depthEach5945.745945.741.0FalseNoneNoneFalseNoneFalse5945.740
3407453120350None8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 SwitchEach7827.187827.181.0FalseNoneNoneFalseNoneFalse7827.180
3407454120350None8.11.2Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2MtrEach312.36312.369.0FalseNoneNoneFalseNoneFalse2811.240
3407455120350None8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panelEach3706.973706.971.0FalseNoneNoneFalseNoneFalse3706.970
3407456120350None8.13.1Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 PairRmtr419.31419.311.0FalseNoneNoneFalseNoneFalse419.310
3407457120350None8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable.m25.5225.52100.0FalseNoneNoneFalseNoneFalse2552.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17196422090000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17196422090000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17196422090000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17196422090000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17196422090000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17196422620000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17196422790000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17196422900000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17196423070000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17196423250000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17196423400000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17196423580000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17196423680000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17196423780000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17196424090000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17196424270000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17196424390000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17196424580000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the workNone
17196424710000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17196424850000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17196425010000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17196425160000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17196425380000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2 b)To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. (2019-20 to 2023-24) b) Satisfactorily completed as prime contractor, at least any construction work of value not less than of Rs. 12.42 Lakhs (25% of the cost of the work) Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonecClause ITT 3.2 d)The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works issued by KPWD/Government Electrical Inspectorate and should have executed similar building electrical works in the last five years i.e (2019-20 to 2023-24) totaling Rs.2.40 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2 e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/KUWS&DB and should have executed similar building water supply/sanitary engineering works in the last five years i.e (2019-20 to 2023-24) totaling Rs. 1.60 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx5.0- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level.N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 3 months.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonePWD Class-III & above Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.2 a)To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. (2019-20 to 2023-24) a)achieved in at least one financial year a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.49.68 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Reserved Category Certificate of Schedule CasteTrueTechnical Bid
Work done Certificate to issued not below the rank of Executive EngineerbeTrueTechnical Bid
KPWD class-III & above Registration CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone