| tenderSubEstimateList | | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
|---|
| 1721637258000 | 1 | None | None | Other Works | 5 percentage works DRILLING BOREWELL,INSTALING MOTOR &CONSTRUCTED CISTERN NEAR ERAPPA BUDNI HOUSE WARD NO. 27 IN RABAKAVI-BANAHATTI CMC LIMITS | 296366.74 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3577323 | 130076 | None | code01 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or each 5141 COMMON SCHEDULE OF RATES 152 2023-24 NO SOR CODE DESCRIPTIONS UNIT RATE Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M
(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. | No | 5446.64 | 5446.64 | 1.0 | False | None | None | False | None | False | 5446.64 | 0 | | 3577324 | 130076 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 0 to 50MTR | Rmtr | 381.1 | 381.1 | 50.0 | False | None | None | False | None | False | 19055.0 | 0 | | 3577325 | 130076 | None | code03 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 50 to 100MTR | Rmtr | 477.92 | 477.92 | 50.0 | False | None | None | False | None | False | 23896.0 | 0 | | 3577326 | 130076 | None | code04 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 100 to 150MTR | Rmtr | 507.79 | 507.79 | 50.0 | False | None | None | False | None | False | 25389.5 | 0 | | 3577327 | 130076 | None | code05 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe
grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Rmtr | 1990.99 | 1990.99 | 12.0 | False | None | None | False | None | False | 23891.88 | 0 | | 3577328 | 130076 | None | code06 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (PartII) 1982 with all amendments | No | 154.5 | 154.5 | 3.0 | False | None | None | False | None | False | 463.5 | 0 | | 3577329 | 130076 | None | code07 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge each 164 | No | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 | | 3577330 | 130076 | None | code08 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3.00 HP - 155 LPM @ 42 m = 3 STG Outlet Dia - 2.00” | No | 25064.02 | 25064.02 | 1.0 | False | None | None | False | None | False | 25064.02 | 0 | | 3577331 | 130076 | None | code09 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990with ISI Mark and as per its latest amendments. | Mtr | 190.55 | 190.55 | 140.0 | False | None | None | False | None | False | 26677.0 | 0 | | 3577332 | 130076 | None | code10 | Supply and delivery at site of brand new best make non-return valve as 50MM | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | | 3577333 | 130076 | None | code11 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e 90MM DAI | No | 9836.5 | 9836.5 | 1.0 | False | None | None | False | None | False | 9836.5 | 0 | | 3577334 | 130076 | None | code12 | Supplying, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveyingto work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 | Rmtr | 483.07 | 483.07 | 140.0 | False | None | None | False | None | False | 67629.8 | 0 | | 3577335 | 130076 | None | code13 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. | Rmtr | 41.2 | 41.2 | 140.0 | False | None | None | False | None | False | 5768.0 | 0 | | 3577336 | 130076 | None | code14 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6695.0 | 6695.0 | 1.0 | False | None | None | False | None | False | 6695.0 | 0 | | 3577337 | 130076 | None | code15 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. | Rmtr | 200.85 | 200.85 | 15.0 | False | None | None | False | None | False | 3012.75 | 0 | | 3577338 | 130076 | None | code16 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | No | 3862.5 | 3862.5 | 1.0 | False | None | None | False | None | False | 3862.5 | 0 | | 3577339 | 130076 | None | code17 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 249.26 | 249.26 | 2.2125 | False | None | None | False | None | False | 551.48775 | 0 | | 3577340 | 130076 | None | code18 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6168.67 | 6168.67 | 1.9049 | False | None | None | False | None | False | 11750.699483 | 0 | | 3577341 | 130076 | None | code19 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6816.54 | 6816.54 | 2.3625 | False | None | None | False | None | False | 16104.07575 | 0 | | 3577342 | 130076 | None | code20 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 364.62 | 364.62 | 2.7 | False | None | None | False | None | False | 984.474 | 0 | | 3577343 | 130076 | None | code21 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm | Each | 16893.03 | 16893.03 | 1.0 | False | None | None | False | None | False | 16893.03 | 0 | | 3577344 | 130076 | None | code22 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. | Job | 1938.46 | 1938.46 | 1.0 | False | None | None | False | None | False | 1938.46 | 0 |
| | 1721637258000 | 1 | None | None | Other Works | TSP WORKS CONSTRUCTION OF TOILET NEAR CHANDRAVVA NAYAK HOUSE AT WARD NO 06, RABKAVI BANAHATTI CMC | 590424.94 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3577345 | 130077 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 18.6606 | False | None | None | False | None | False | 6977.011734 | 0 | | 3577346 | 130077 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 3.8449 | False | None | None | False | None | False | 23717.919283 | 0 | | 3577347 | 130077 | None | code03 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 6.7798 | False | None | None | False | None | False | 3310.033956 | 0 | | 3577348 | 130077 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 6.804 | False | None | None | False | None | False | 39322.56132 | 0 | | 3577349 | 130077 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 9.7877 | False | None | None | False | None | False | 63381.327997 | 0 | | 3577350 | 130077 | None | code06 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Footing @ 3% | Cum | 194.26 | 194.26 | 1.0125 | False | None | None | False | None | False | 196.68825 | 0 | | 3577351 | 130077 | None | code07 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Columns @ 70% | Cum | 4532.92 | 4532.92 | 2.4318 | False | None | None | False | None | False | 11023.154856 | 0 | | 3577352 | 130077 | None | code08 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 2.1088 | False | None | None | False | None | False | 8193.447168 | 0 | | 3577353 | 130077 | None | code09 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Slab 50% | Cum | 3237.8 | 3237.8 | 3.725 | False | None | None | False | None | False | 12060.805 | 0 | | 3577354 | 130077 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 1.0766 | False | None | None | False | None | False | 99198.688386 | 0 | | 3577355 | 130077 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 13.0768 | False | None | None | False | None | False | 107456.511712 | 0 | | 3577356 | 130077 | None | code12 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 14.259 | False | None | None | False | None | False | 14334.28752 | 0 | | 3577357 | 130077 | None | code13 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 92.795 | False | None | None | False | None | False | 24372.60675 | 0 | | 3577358 | 130077 | None | code14 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 59.85 | False | None | None | False | None | False | 22870.4805 | 0 | | 3577359 | 130077 | None | code15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 11.1232 | False | None | None | False | None | False | 12396.361472 | 0 | | 3577360 | 130077 | None | code16 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 8.082 | False | None | None | False | None | False | 11587.64832 | 0 | | 3577361 | 130077 | None | code17 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 7.875 | False | None | None | False | None | False | 2579.3775 | 0 | | 3577362 | 130077 | None | code18 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 7.875 | False | None | None | False | None | False | 12880.665 | 0 | | 3577363 | 130077 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 152.645 | False | None | None | False | None | False | 16980.2298 | 0 | | 3577364 | 130077 | None | code20 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 4.0 | False | None | None | False | None | False | 9603.72 | 0 | | 3577365 | 130077 | None | code21 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 1.0 | False | None | None | False | None | False | 4980.05 | 0 | | 3577366 | 130077 | None | code22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 1.0 | False | None | None | False | None | False | 3174.46 | 0 | | 3577367 | 130077 | None | code23 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 11.0 | False | None | None | False | None | False | 10536.9 | 0 | | 3577368 | 130077 | None | code24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Nos | 304.88 | 304.88 | 40.0 | False | None | None | False | None | False | 12195.2 | 0 | | 3577369 | 130077 | None | code25 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 2.0 | False | None | None | False | None | False | 11622.52 | 0 | | 3577370 | 130077 | None | code26 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 | | 3577371 | 130077 | None | code27 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 2.0 | False | None | None | False | None | False | 453.2 | 0 | | 3577372 | 130077 | None | code28 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 5.0 | False | None | None | False | None | False | 1472.9 | 0 | | 3577373 | 130077 | None | code29 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 2.52 | False | None | None | False | None | False | 21481.1856 | 0 | | 3577374 | 130077 | None | code30 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 15.0 | False | None | None | False | None | False | 990.0 | 0 | | 3577375 | 130077 | None | code31 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 15.0 | False | None | None | False | None | False | 1170.0 | 0 | | 3577376 | 130077 | None | code32 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 15.0 | False | None | None | False | None | False | 390.0 | 0 | | 3577377 | 130077 | None | code33 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 15.0 | False | None | None | False | None | False | 630.0 | 0 | | 3577378 | 130077 | None | code34 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 10.0 | False | None | None | False | None | False | 630.0 | 0 | | 3577379 | 130077 | None | code35 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 2.0 | False | None | None | False | None | False | 538.0 | 0 | | 3577380 | 130077 | None | code36 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 2.0 | False | None | None | False | None | False | 748.0 | 0 | | 3577381 | 130077 | None | code37 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 3577382 | 130077 | None | code38 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 3.0 | False | None | None | False | None | False | 477.0 | 0 | | 3577383 | 130077 | None | code39 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | | 3577384 | 130077 | None | code40 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 module | Each | 161.0 | 161.0 | 3.0 | False | None | None | False | None | False | 483.0 | 0 | | 3577385 | 130077 | None | code41 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | | 3577386 | 130077 | None | code42 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 6.0 | False | None | None | False | None | False | 612.0 | 0 | | 3577387 | 130077 | None | code43 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 2.0 | False | None | None | False | None | False | 1942.0 | 0 | | 3577388 | 130077 | None | code44 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | | 3577389 | 130077 | None | code45 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 6.0 | False | None | None | False | None | False | 1956.0 | 0 |
| | 1721637258000 | 1 | None | None | Other Works | SCP WORKS CONSTRUCTION OF TOILETS AND PIPE LINE WORKS AT RABKAVI BANHATTI CMC | 3008751.99 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3577390 | 130078 | None | code01 | Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. Cutting in Cement Concrete Road Surface | Cum | 1191.71 | 1191.71 | 26.8312 | False | None | None | False | None | False | 31975.009352 | 0 | | 3577391 | 130078 | None | code02 | Earth work excavatoin for water Supply & Sanitary lines, Electrical conduits either in pits or pipe line trenches (upto 600mm Trench width) as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, using sight rails & boning rods at every 100 mm whevere necessary removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench, including backfilling the excavated earth to the extent required and utilising the remaining available excavated earth locally for the work. in the following strata classifications by Mechanical Means. Ordinary / Hard Soil - (Depth upto 3m) | Cum | 269.86 | 269.86 | 160.9875 | False | None | None | False | None | False | 43444.08675 | 0 | | 3577392 | 130078 | None | code03 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 m | Mtr | 423.33 | 423.33 | 397.5 | False | None | None | False | None | False | 168273.675 | 0 | | 3577393 | 130078 | None | code04 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 107.325 | False | None | None | False | None | False | 17687.16 | 0 | | 3577394 | 130078 | None | code05 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification includingpremixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2635.77 | 2635.77 | 26.8312 | False | None | None | False | None | False | 70720.872024 | 0 | | 3577395 | 130078 | None | code06 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (2nd Quarter Revision of Rates for cement related items M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 6565.22 | 6565.22 | 26.8312 | False | None | None | False | None | False | 176152.730864 | 0 | | 3577396 | 130078 | None | code07 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 78.5305 | False | None | None | False | None | False | 29361.768645 | 0 | | 3577397 | 130078 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 24.5438 | False | None | None | False | None | False | 151402.602746 | 0 | | 3577398 | 130078 | None | code09 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 23.9688 | False | None | None | False | None | False | 138523.604904 | 0 | | 3577399 | 130078 | None | code10 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 59.7729 | False | None | None | False | None | False | 29182.325238 | 0 | | 3577400 | 130078 | None | code11 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 44.2398 | False | None | None | False | None | False | 286479.691278 | 0 | | 3577401 | 130078 | None | code12 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Footing @ 3% | Cum | 194.26 | 194.26 | 2.7 | False | None | None | False | None | False | 524.502 | 0 | | 3577402 | 130078 | None | code13 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Columns @ 70% | Cum | 4532.92 | 4532.92 | 5.0784 | False | None | None | False | None | False | 23019.980928 | 0 | | 3577403 | 130078 | None | code14 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 34.0192 | False | None | None | False | None | False | 132176.838912 | 0 | | 3577404 | 130078 | None | code15 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Slab 50% | Cum | 3237.8 | 3237.8 | 2.1 | False | None | None | False | None | False | 6799.38 | 0 | | 3577405 | 130078 | None | code16 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 4.9023 | False | None | None | False | None | False | 451701.402633 | 0 | | 3577406 | 130078 | None | code17 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 32.6968 | False | None | None | False | None | False | 268680.722512 | 0 | | 3577407 | 130078 | None | code18 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 48.027 | False | None | None | False | None | False | 48280.58256 | 0 | | 3577408 | 130078 | None | code19 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 255.879 | False | None | None | False | None | False | 67206.61935 | 0 | | 3577409 | 130078 | None | code20 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 204.019 | False | None | None | False | None | False | 77961.78047 | 0 | | 3577410 | 130078 | None | code21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 69.7758 | False | None | None | False | None | False | 77762.338068 | 0 | | 3577411 | 130078 | None | code22 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 9.9 | False | None | None | False | None | False | 14194.224 | 0 | | 3577412 | 130078 | None | code23 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 73.125 | False | None | None | False | None | False | 23951.3625 | 0 | | 3577413 | 130078 | None | code24 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 23.625 | False | None | None | False | None | False | 38641.995 | 0 | | 3577414 | 130078 | None | code25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 459.899 | False | None | None | False | None | False | 51159.16476 | 0 | | 3577415 | 130078 | None | code26 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 12.0 | False | None | None | False | None | False | 28811.16 | 0 | | 3577416 | 130078 | None | code27 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 3.0 | False | None | None | False | None | False | 14940.15 | 0 | | 3577417 | 130078 | None | code28 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 5.0 | False | None | None | False | None | False | 15872.3 | 0 | | 3577418 | 130078 | None | code29 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 50.0 | False | None | None | False | None | False | 47895.0 | 0 | | 3577419 | 130078 | None | code30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Nos | 304.88 | 304.88 | 104.0 | False | None | None | False | None | False | 31707.52 | 0 | | 3577420 | 130078 | None | code31 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 10.0 | False | None | None | False | None | False | 58112.6 | 0 | | 3577421 | 130078 | None | code32 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 5000.0 | False | None | None | False | None | False | 46350.0 | 0 | | 3577422 | 130078 | None | code33 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 6.0 | False | None | None | False | None | False | 1359.6 | 0 | | 3577423 | 130078 | None | code34 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 21.0 | False | None | None | False | None | False | 6186.18 | 0 | | 3577424 | 130078 | None | code35 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 7.56 | False | None | None | False | None | False | 64443.5568 | 0 | | 3577425 | 130078 | None | code36 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 45.0 | False | None | None | False | None | False | 2970.0 | 0 | | 3577426 | 130078 | None | code37 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 45.0 | False | None | None | False | None | False | 3510.0 | 0 | | 3577427 | 130078 | None | code38 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 45.0 | False | None | None | False | None | False | 1170.0 | 0 | | 3577428 | 130078 | None | code39 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 45.0 | False | None | None | False | None | False | 1890.0 | 0 | | 3577429 | 130078 | None | code40 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | | 3577430 | 130078 | None | code41 | POINT WIRING USING COPPER WIRE WITHOUT SWITCHSupplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 6.0 | False | None | None | False | None | False | 1614.0 | 0 | | 3577431 | 130078 | None | code42 | POINT WIRING USING COPPER WIRE WITHOUT SWITCHSupplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 6.0 | False | None | None | False | None | False | 2244.0 | 0 | | 3577432 | 130078 | None | code43 | POINT WIRING USING COPPER WIRE WITHOUT SWITCHSupplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 6.0 | False | None | None | False | None | False | 3330.0 | 0 | | 3577433 | 130078 | None | code44 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 9.0 | False | None | None | False | None | False | 1431.0 | 0 | | 3577434 | 130078 | None | code45 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 6.0 | False | None | None | False | None | False | 1062.0 | 0 | | 3577435 | 130078 | None | code46 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 module | Each | 161.0 | 161.0 | 9.0 | False | None | None | False | None | False | 1449.0 | 0 | | 3577436 | 130078 | None | code47 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 6.0 | False | None | None | False | None | False | 1050.0 | 0 | | 3577437 | 130078 | None | code48 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 12.0 | False | None | None | False | None | False | 1224.0 | 0 | | 3577438 | 130078 | None | code49 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 4.0 | False | None | None | False | None | False | 3884.0 | 0 | | 3577439 | 130078 | None | code50 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 | | 3577440 | 130078 | None | code51 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 16.0 | False | None | None | False | None | False | 5216.0 | 0 | | 3577441 | 130078 | None | code52 | borewell Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or each 5141 COMMON SCHEDULE OF RATES 152 2023-24 NO SOR CODE DESCRIPTIONS UNIT RATE Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M
(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. | No | 5446.64 | 5446.64 | 1.0 | False | None | None | False | None | False | 5446.64 | 0 | | 3577442 | 130078 | None | code53 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 0 to 50MTR | Rmtr | 381.1 | 381.1 | 50.0 | False | None | None | False | None | False | 19055.0 | 0 | | 3577443 | 130078 | None | code54 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 50 to 100MTR | Rmtr | 477.92 | 477.92 | 50.0 | False | None | None | False | None | False | 23896.0 | 0 | | 3577444 | 130078 | None | code55 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 100 to 150MTR | Rmtr | 507.79 | 507.79 | 50.0 | False | None | None | False | None | False | 25389.5 | 0 | | 3577445 | 130078 | None | code56 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 150 to 200 | Rmtr | 589.16 | 589.16 | 50.0 | False | None | None | False | None | False | 29458.0 | 0 | | 3577446 | 130078 | None | code57 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe
grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Rmtr | 1990.99 | 1990.99 | 18.0 | False | None | None | False | None | False | 35837.82 | 0 | | 3577447 | 130078 | None | code58 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (PartII) 1982 with all amendments | No | 154.5 | 154.5 | 4.0 | False | None | None | False | None | False | 618.0 | 0 | | 3577448 | 130078 | None | code59 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge each 164 | No | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 | | 3577449 | 130078 | None | code60 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3.00 HP - 155 LPM @ 42 m = 3 STG Outlet Dia - 2.00” | No | 25064.02 | 25064.02 | 1.0 | False | None | None | False | None | False | 25064.02 | 0 | | 3577450 | 130078 | None | code61 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990with ISI Mark and as per its latest amendments. | Mtr | 190.55 | 190.55 | 180.0 | False | None | None | False | None | False | 34299.0 | 0 | | 3577451 | 130078 | None | code62 | Supply and delivery at site of brand new best make non-return valve as 50MM | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | | 3577452 | 130078 | None | code63 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ
e 90MM DAI | No | 9836.5 | 9836.5 | 1.0 | False | None | None | False | None | False | 9836.5 | 0 | | 3577453 | 130078 | None | code64 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations an rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 | Rmtr | 483.07 | 483.07 | 1.0125 | False | None | None | False | None | False | 489.108375 | 0 | | 3577454 | 130078 | None | code65 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with | Rmtr | 41.2 | 41.2 | 175.0 | False | None | None | False | None | False | 7210.0 | 0 | | 3577455 | 130078 | None | code66 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and
erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6695.0 | 6695.0 | 1.0 | False | None | None | False | None | False | 6695.0 | 0 | | 3577456 | 130078 | None | code67 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. | Rmtr | 200.85 | 200.85 | 20.0 | False | None | None | False | None | False | 4017.0 | 0 | | 3577457 | 130078 | None | code68 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Nos | 3862.5 | 3862.5 | 1.0 | False | None | None | False | None | False | 3862.5 | 0 |
| | 1721637258000 | 1 | None | None | Other Works | WORKS(7.25 PERCENTAGE) CONSTRUCTION OF GENTS TOILET AT RABKAVI BANHATTI CMC | 2369936.11 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3577458 | 130079 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 82.4652 | False | None | None | False | None | False | 30832.913628 | 0 | | 3577459 | 130079 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 20.2328 | False | None | None | False | None | False | 124809.466376 | 0 | | 3577460 | 130079 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 25.7857 | False | None | None | False | None | False | 149024.069581 | 0 | | 3577461 | 130079 | None | code04 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 78.1696 | False | None | None | False | None | False | 38163.962112 | 0 | | 3577462 | 130079 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 34.7349 | False | None | None | False | None | False | 224929.665789 | 0 | | 3577463 | 130079 | None | code06 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Footing @ 3% | Cum | 194.26 | 194.26 | 3.0374 | False | None | None | False | None | False | 590.045324 | 0 | | 3577464 | 130079 | None | code07 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Columns @ 70% | Cum | 4532.92 | 4532.92 | 5.0301 | False | None | None | False | None | False | 22801.040892 | 0 | | 3577465 | 130079 | None | code08 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 12.4743 | False | None | None | False | None | False | 48467.146248 | 0 | | 3577466 | 130079 | None | code09 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Slab 50% | Cum | 3237.8 | 3237.8 | 14.193 | False | None | None | False | None | False | 45954.0954 | 0 | | 3577467 | 130079 | None | code10 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 3.9752 | False | None | None | False | None | False | 366277.750392 | 0 | | 3577468 | 130079 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 34.2792 | False | None | None | False | None | False | 281683.841328 | 0 | | 3577469 | 130079 | None | code12 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 61.6769 | False | None | None | False | None | False | 62002.554032 | 0 | | 3577470 | 130079 | None | code13 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 372.465 | False | None | None | False | None | False | 97827.93225 | 0 | | 3577471 | 130079 | None | code14 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 202.86 | False | None | None | False | None | False | 77518.8918 | 0 | | 3577472 | 130079 | None | code15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 62.004 | False | None | None | False | None | False | 69100.97784 | 0 | | 3577473 | 130079 | None | code16 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 11.178 | False | None | None | False | None | False | 16026.56928 | 0 | | 3577474 | 130079 | None | code17 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 33.075 | False | None | None | False | None | False | 10833.3855 | 0 | | 3577475 | 130079 | None | code18 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 33.075 | False | None | None | False | None | False | 54098.793 | 0 | | 3577476 | 130079 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 575.325 | False | None | None | False | None | False | 63999.153 | 0 | | 3577477 | 130079 | None | code20 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 18.0 | False | None | None | False | None | False | 43216.74 | 0 | | 3577478 | 130079 | None | code21 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 3.0 | False | None | None | False | None | False | 14940.15 | 0 | | 3577479 | 130079 | None | code22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 3.0 | False | None | None | False | None | False | 9523.38 | 0 | | 3577480 | 130079 | None | code23 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 56.0 | False | None | None | False | None | False | 53642.4 | 0 | | 3577481 | 130079 | None | code24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Nos | 304.88 | 304.88 | 140.0 | False | None | None | False | None | False | 42683.2 | 0 | | 3577482 | 130079 | None | code25 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 6.0 | False | None | None | False | None | False | 34867.56 | 0 | | 3577483 | 130079 | None | code26 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 4000.0 | False | None | None | False | None | False | 37080.0 | 0 | | 3577484 | 130079 | None | code27 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 6.0 | False | None | None | False | None | False | 1359.6 | 0 | | 3577485 | 130079 | None | code28 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 27.0 | False | None | None | False | None | False | 7953.66 | 0 | | 3577486 | 130079 | None | code29 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 7.56 | False | None | None | False | None | False | 64443.5568 | 0 | | 3577487 | 130079 | None | code30 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required
pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of
Engineer-in-charge | Sqm | 824.0 | 824.0 | 240.0 | False | None | None | False | None | False | 197760.0 | 0 | | 3577488 | 130079 | None | code31 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6458.1 | 6458.1 | 6.0 | False | None | None | False | None | False | 38748.6 | 0 | | 3577489 | 130079 | None | code32 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 45.0 | False | None | None | False | None | False | 2970.0 | 0 | | 3577490 | 130079 | None | code33 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 30.0 | False | None | None | False | None | False | 2340.0 | 0 | | 3577491 | 130079 | None | code34 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 45.0 | False | None | None | False | None | False | 1170.0 | 0 | | 3577492 | 130079 | None | code35 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 | | 3577493 | 130079 | None | code36 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 24.0 | False | None | None | False | None | False | 1512.0 | 0 | | 3577494 | 130079 | None | code37 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 6.0 | False | None | None | False | None | False | 1614.0 | 0 | | 3577495 | 130079 | None | code38 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 6.0 | False | None | None | False | None | False | 2244.0 | 0 | | 3577496 | 130079 | None | code39 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 6.0 | False | None | None | False | None | False | 3330.0 | 0 | | 3577497 | 130079 | None | code40 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 9.0 | False | None | None | False | None | False | 1431.0 | 0 | | 3577498 | 130079 | None | code41 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 6.0 | False | None | None | False | None | False | 1062.0 | 0 | | 3577499 | 130079 | None | code42 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 module | Each | 161.0 | 161.0 | 9.0 | False | None | None | False | None | False | 1449.0 | 0 | | 3577500 | 130079 | None | code43 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 6.0 | False | None | None | False | None | False | 1050.0 | 0 | | 3577501 | 130079 | None | code44 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 24.0 | False | None | None | False | None | False | 2448.0 | 0 | | 3577502 | 130079 | None | code45 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 6.0 | False | None | None | False | None | False | 5826.0 | 0 | | 3577503 | 130079 | None | code46 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 | | 3577504 | 130079 | None | code47 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 24.0 | False | None | None | False | None | False | 7824.0 | 0 |
| | 1721637258000 | 1 | None | None | Other Works | GENERAL WORKS CONSTRUCTION OF DHOBI GHATS ROW PLANTS, COMPOND WALLS ,CC ROADS,AND ANGANVADI AND TOILETS BUILDING AT RABKAVI BANAHATTI CMC | 10123181.96 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3577505 | 130080 | None | code01 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar | Cum | 1031.03 | 1031.03 | 21.6 | False | None | None | False | None | False | 22270.248 | 0 | | 3577506 | 130080 | None | code02 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 1734.52 | 1734.52 | 8.25 | False | None | None | False | None | False | 14309.79 | 0 | | 3577507 | 130080 | None | code03 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 496.46 | 496.46 | 40.4352 | False | None | None | False | None | False | 20074.459392 | 0 | | 3577508 | 130080 | None | code04 | Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge | Cum | 815.76 | 815.76 | 17.01 | False | None | None | False | None | False | 13876.0776 | 0 | | 3577509 | 130080 | None | code05 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 413.176 | False | None | None | False | None | False | 154482.37464 | 0 | | 3577510 | 130080 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 129.554 | False | None | None | False | None | False | 799175.87318 | 0 | | 3577511 | 130080 | None | code07 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 32.3784 | False | None | None | False | None | False | 187125.458472 | 0 | | 3577512 | 130080 | None | code08 | Providing Coursed rubble masonry (first sort) with hard stone infoundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6816.54 | 6816.54 | 84.1833 | False | None | None | False | None | False | 573838.831782 | 0 | | 3577513 | 130080 | None | code09 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 507.79 | 507.79 | 1951.95 | False | None | None | False | None | False | 991180.6905 | 0 | | 3577514 | 130080 | None | code10 | Loosening, leveling and Compacting original ground supportingembankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm, mixed with water at OMC andthen compacted by rolling so as to achieve minimum dry densityas given in Table 300-2 for embankment construction. | Cum | 108.15 | 108.15 | 67.8 | False | None | None | False | None | False | 7332.57 | 0 | | 3577515 | 130080 | None | code11 | Construction of dry lean cement concrete Sub- base over aprepared sub-grade with coarse and fine aggregate conformingto IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradationafter blending to be as per table 600-1, cement content not to beless than 150 kg/ m3, optimum moisture content to be determinedduring trial length construction, concrete strength not to be lessthan 10 Mpa at 7 days, mixed in a batching plant, transportedto site, laid with a paver with electronic sensor, compacting with8-10 t vibratory roller, finishing and curing Construction of dry lean cement concrete | Cum | 5067.6 | 5067.6 | 32.0 | False | None | None | False | None | False | 162163.2 | 0 | | 3577516 | 130080 | None | code12 | Providing and constructing un-reinforced plain cementconcrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork (steel channel,laying and fixing of 125 micron thick polythene film,wedges, steel plates including levelling the formwork asper drawing), spreading the concrete with shovels, rakes,compacted using needle, screed and plate vibrators andfinished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts,loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per thedirections of the Engineer-in-charge of the work. | Cum | 6956.62 | 6956.62 | 45.0 | False | None | None | False | None | False | 313047.9 | 0 | | 3577517 | 130080 | None | code13 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 150.429 | False | None | None | False | None | False | 73442.44638 | 0 | | 3577518 | 130080 | None | code14 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 208.474 | False | None | None | False | None | False | 1349996.31914 | 0 | | 3577519 | 130080 | None | code15 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24Footing @ 3% | Cum | 194.26 | 194.26 | 10.889 | False | None | None | False | None | False | 2115.29714 | 0 | | 3577520 | 130080 | None | code16 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24Columns @ 70% | Cum | 4532.92 | 4532.92 | 13.869 | False | None | None | False | None | False | 62867.06748 | 0 | | 3577521 | 130080 | None | code17 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 67.3622 | False | None | None | False | None | False | 261726.397392 | 0 | | 3577522 | 130080 | None | code18 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24Slab 50% | Cum | 3237.8 | 3237.8 | 6.625 | False | None | None | False | None | False | 21450.425 | 0 | | 3577523 | 130080 | None | code19 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 10.708 | False | None | None | False | None | False | 986642.72268 | 0 | | 3577524 | 130080 | None | code20 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 121.7965 | False | None | None | False | None | False | 1000843.25131 | 0 | | 3577525 | 130080 | None | code21 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. DSR 2023-24 | Cum | 8457.33 | 8457.33 | 4.536 | False | None | None | False | None | False | 38362.44888 | 0 | | 3577526 | 130080 | None | code22 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 82.983 | False | None | None | False | None | False | 83421.15024 | 0 | | 3577527 | 130080 | None | code23 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 787.962 | False | None | None | False | None | False | 206958.2193 | 0 | | 3577528 | 130080 | None | code24 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 971.5816 | False | None | None | False | None | False | 371270.476808 | 0 | | 3577529 | 130080 | None | code25 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials,labour, curing, polishing complete as per specifications. | Sqm | 382.13 | 382.13 | 71.9315 | False | None | None | False | None | False | 27487.184095 | 0 | | 3577530 | 130080 | None | code26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 113.82 | False | None | None | False | None | False | 126847.8372 | 0 | | 3577531 | 130080 | None | code27 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 118.884 | False | None | None | False | None | False | 170451.12384 | 0 | | 3577532 | 130080 | None | code28 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 188.1 | False | None | None | False | None | False | 61610.274 | 0 | | 3577533 | 130080 | None | code29 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 51.975 | False | None | None | False | None | False | 85012.389 | 0 | | 3577534 | 130080 | None | code30 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 101779.45 | 101779.45 | 0.12 | False | None | None | False | None | False | 12213.534 | 0 | | 3577535 | 130080 | None | code31 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 5914.26 | 5914.26 | 3.78 | False | None | None | False | None | False | 22355.9028 | 0 | | 3577536 | 130080 | None | code32 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 g/l, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two coats on new work to give an even shade after thoroughly brooming thesurface to remove all dirt, dust, mortar drops and foreign matter includingpreparing the surface even and sand paper smooth, cost of materials, labourcomplete as per specifications and as per directions of Engineer-in-charge.SR 2023-24 | Sqm | 82.4 | 82.4 | 429.46 | False | None | None | False | None | False | 35387.504 | 0 | | 3577537 | 130080 | None | code33 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 1199.073 | False | None | None | False | None | False | 133384.88052 | 0 | | 3577538 | 130080 | None | code34 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 118.45 | 118.45 | 28.8 | False | None | None | False | None | False | 3411.36 | 0 | | 3577539 | 130080 | None | code35 | Providing and laying flooring with burnt stone slabs 10 cms thick, rough chistle dressed on sand bed 7.5 cms to 8 cms thick and pointed with cement mortar 1:3, , including cost of materials, sand, labour, curing complete as per specifications | Sqm | 2441.1 | 2441.1 | 4.5 | False | None | None | False | None | False | 10984.95 | 0 | | 3577540 | 130080 | None | code36 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 29.0 | False | None | None | False | None | False | 69626.97 | 0 | | 3577541 | 130080 | None | code37 | Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings :Flat back wash basin of size 630x450 mmSR 2023-24 | Each | 1015.58 | 1015.58 | 1.0 | False | None | None | False | None | False | 1015.58 | 0 | | 3577542 | 130080 | None | code38 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 4.0 | False | None | None | False | None | False | 19920.2 | 0 | | 3577543 | 130080 | None | code39 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 8.0 | False | None | None | False | None | False | 25395.68 | 0 | | 3577544 | 130080 | None | code40 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 210.0 | False | None | None | False | None | False | 201159.0 | 0 | | 3577545 | 130080 | None | code41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 304.88 | 304.88 | 275.0 | False | None | None | False | None | False | 83842.0 | 0 | | 3577546 | 130080 | None | code42 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 188.49 | 188.49 | 450.0 | False | None | None | False | None | False | 84820.5 | 0 | | 3577547 | 130080 | None | code43 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 18.0 | False | None | None | False | None | False | 104602.68 | 0 | | 3577548 | 130080 | None | code44 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 8500.0 | False | None | None | False | None | False | 78795.0 | 0 | | 3577549 | 130080 | None | code45 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 8.0 | False | None | None | False | None | False | 1812.8 | 0 | | 3577550 | 130080 | None | code46 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 40.0 | False | None | None | False | None | False | 11783.2 | 0 | | 3577551 | 130080 | None | code47 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 13.86 | False | None | None | False | None | False | 118146.5208 | 0 | | 3577552 | 130080 | None | code48 | Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 522.21 | 522.21 | 11.5625 | False | None | None | False | None | False | 6038.053125 | 0 | | 3577553 | 130080 | None | code49 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 90.0 | False | None | None | False | None | False | 5940.0 | 0 | | 3577554 | 130080 | None | code50 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 90.0 | False | None | None | False | None | False | 7020.0 | 0 | | 3577555 | 130080 | None | code51 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 105.0 | False | None | None | False | None | False | 2730.0 | 0 | | 3577556 | 130080 | None | code52 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 75.0 | False | None | None | False | None | False | 3150.0 | 0 | | 3577557 | 130080 | None | code53 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | | 3577558 | 130080 | None | code54 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 14.0 | False | None | None | False | None | False | 3766.0 | 0 | | 3577559 | 130080 | None | code55 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 8.0 | False | None | None | False | None | False | 2992.0 | 0 | | 3577560 | 130080 | None | code56 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 12.0 | False | None | None | False | None | False | 6660.0 | 0 | | 3577561 | 130080 | None | code57 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 12.0 | False | None | None | False | None | False | 1908.0 | 0 | | 3577562 | 130080 | None | code58 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 | | 3577563 | 130080 | None | code59 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 module | Each | 161.0 | 161.0 | 12.0 | False | None | None | False | None | False | 1932.0 | 0 | | 3577564 | 130080 | None | code60 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 8.0 | False | None | None | False | None | False | 1400.0 | 0 | | 3577565 | 130080 | None | code61 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 16.0 | False | None | None | False | None | False | 1632.0 | 0 | | 3577566 | 130080 | None | code62 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 6.0 | False | None | None | False | None | False | 5826.0 | 0 | | 3577567 | 130080 | None | code63 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 4.0 | False | None | None | False | None | False | 1660.0 | 0 | | 3577568 | 130080 | None | code64 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 44.0 | False | None | None | False | None | False | 14344.0 | 0 | | 3577569 | 130080 | None | code65 | RO PLANT Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Sl. No.1.1, Page No.5 of PWD SR 2021-22 of Volume1. | Sqm | 93.73 | 93.73 | 25.0 | False | None | None | False | None | False | 2343.25 | 0 | | 3577570 | 130080 | None | code66 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Sl. No.1.14.1, Page No.8 of PWD SR 2021-22 of Volume1. | Cum | 105.06 | 105.06 | 25.758 | False | None | None | False | None | False | 2706.13548 | 0 | | 3577571 | 130080 | None | code67 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Sl. No.4.1, Page No.5 of PWD SR 2021-22 of Volume2. | Sqm | 121.54 | 121.54 | 16.0 | False | None | None | False | None | False | 1944.64 | 0 | | 3577572 | 130080 | None | code68 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). Sl. No.5.4, Page No.9 of PWD SR 2021-22 of Volume2. | Cum | 6580.67 | 6580.67 | 5.9928 | False | None | None | False | None | False | 39436.639176 | 0 | | 3577573 | 130080 | None | code69 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Sl. No.2.1.2, Page No.15 of PWD SR 2021-22 of Volume1. Revised Rate W.E.F From 04-01-2023. | Cum | 5833.92 | 5833.92 | 3.393 | False | None | None | False | None | False | 19794.49056 | 0 | | 3577574 | 130080 | None | code70 | Providing and laying in position Reinforced cement concrete for allSub structures of building, Irrigation works, Sub structure works ofbridges, Drain works & other parallel works from 0.50m to 3.50 mheight. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other. appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement & formwork to be paidseparately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sl. No.2.4.3, Page No.17 of PWD SR 2021-22 of Volume1. Revised Rate W.E.F From 04-01-2023. | Cum | 6526.08 | 6526.08 | 2.7 | False | None | None | False | None | False | 17620.416 | 0 | | 3577575 | 130080 | None | code71 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sl. No.2.5.2, Page No.17 of PWD SR 2021-22 of Volume1. Revised Rate W.E.F From 04-01-2023. | Cum | 7048.29 | 7048.29 | 6.455 | False | None | None | False | None | False | 45496.71195 | 0 | | 3577576 | 130080 | None | code72 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Sl. No.1.9, Page No.7 of PWD SR 2021-22 of Volume1. | Cum | 273.98 | 273.98 | 15.1376 | False | None | None | False | None | False | 4147.399648 | 0 | | 3577577 | 130080 | None | code73 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Footing. (8%) | Sqm | 522.08 | 522.08 | 2.7 | False | None | None | False | None | False | 1409.616 | 0 | | 3577578 | 130080 | None | code74 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Columns. (70%) | Sqm | 4933.8 | 4933.8 | 2.07 | False | None | None | False | None | False | 10212.966 | 0 | | 3577579 | 130080 | None | code75 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Lintel Beams and roof beams (60%) | Sqm | 4228.97 | 4228.97 | 0.6265 | False | None | None | False | None | False | 2649.449705 | 0 | | 3577580 | 130080 | None | code76 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Roof. (50%) | Sqm | 3524.14 | 3524.14 | 3.2725 | False | None | None | False | None | False | 11532.74815 | 0 | | 3577581 | 130080 | None | code77 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Chejja (45%) | Sqm | 3171.73 | 3171.73 | 0.486 | False | None | None | False | None | False | 1541.46078 | 0 | | 3577582 | 130080 | None | code78 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Building | Tonne | 92140.71 | 92140.71 | 0.9363 | False | None | None | False | None | False | 86271.346773 | 0 | | 3577583 | 130080 | None | code79 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P. No.13, I. No.6.7, Volume-2,) Revised Rate W.E.F. 04-01-2023 | Cum | 8457.33 | 8457.33 | 4.4022 | False | None | None | False | None | False | 37230.858126 | 0 | | 3577584 | 130080 | None | code80 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.1.1. Page No.41 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2023 | Sqm | 262.65 | 262.65 | 12.5316 | False | None | None | False | None | False | 3291.42474 | 0 | | 3577585 | 130080 | None | code81 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.9, Page No.42 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2023 | Sqm | 382.13 | 382.13 | 66.4 | False | None | None | False | None | False | 25373.432 | 0 | | 3577586 | 130080 | None | code82 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.5.1, Page No.42 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2023 | Sqm | 376.98 | 376.98 | 10.62 | False | None | None | False | None | False | 4003.5276 | 0 | | 3577587 | 130080 | None | code83 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm ( Vol -2, I No - 9.22.2 , P No - 63, PWD SR - 2021-22 ) | Sqm | 1365.78 | 1365.78 | 14.411 | False | None | None | False | None | False | 19682.25558 | 0 | | 3577588 | 130080 | None | code84 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No.11.34A, Page No.85 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2022 | Kgs | 173.04 | 173.04 | 233.1 | False | None | None | False | None | False | 40335.624 | 0 | | 3577589 | 130080 | None | code85 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sl. No.12.90, Page No.112 of PWD SR 2021-22 of Volume2. | Sqm | 6936.02 | 6936.02 | 11.1 | False | None | None | False | None | False | 76989.822 | 0 | | 3577590 | 130080 | None | code86 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2742.89 | 2742.89 | 5.25 | False | None | None | False | None | False | 14400.1725 | 0 | | 3577591 | 130080 | None | code87 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.40, Page No.48 of PWD SR 2021-22 of Volume2. | Sqm | 118.45 | 118.45 | 16.35 | False | None | None | False | None | False | 1936.6575 | 0 | | 3577592 | 130080 | None | code88 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.30, Page No.46 of PWD SR 2021-22 of Volume2. | Sqm | 179.22 | 179.22 | 66.4 | False | None | None | False | None | False | 11900.208 | 0 | | 3577593 | 130080 | None | code89 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Vol -2, I No - 8.33.1 , P No - 46, PWD SR - 2021-22 ) | Sqm | 162.74 | 162.74 | 10.62 | False | None | None | False | None | False | 1728.2988 | 0 | | 3577594 | 130080 | None | code90 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thick | Mtr | 66.0 | 66.0 | 25.0 | False | None | None | False | None | False | 1650.0 | 0 | | 3577595 | 130080 | None | code91 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box. | Point | 394.0 | 394.0 | 1.0 | False | None | None | False | None | False | 394.0 | 0 | | 3577596 | 130080 | None | code92 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22 Long point above 6m upto 10m from tapping point to out let via switch box | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 | | 3577597 | 130080 | None | code93 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Three outlet in a row, above 6m upto 10m from tapping point to out let via switche | Point | 1035.0 | 1035.0 | 2.0 | False | None | None | False | None | False | 2070.0 | 0 | | 3577598 | 130080 | None | code94 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical SR 2021-22, 1.5 mm2 | Mtr | 26.0 | 26.0 | 90.0 | False | None | None | False | None | False | 2340.0 | 0 | | 3577599 | 130080 | None | code95 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical SR 2021-22, 2.5 mm2 | Mtr | 42.0 | 42.0 | 90.0 | False | None | None | False | None | False | 3780.0 | 0 | | 3577600 | 130080 | None | code96 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. PWD Electrical SR 2021-22, 4 mm2 | Mtr | 63.0 | 63.0 | 45.0 | False | None | None | False | None | False | 2835.0 | 0 | | 3577601 | 130080 | None | code97 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654, 6A 3/5 Way | Each | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 | | 3577602 | 130080 | None | code98 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 | | 3577603 | 130080 | None | code99 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket | Each | 236.0 | 236.0 | 8.0 | False | None | None | False | None | False | 1888.0 | 0 | | 3577604 | 130080 | None | code100 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-3 Way | Each | 138.0 | 138.0 | 1.0 | False | None | None | False | None | False | 138.0 | 0 | | 3577605 | 130080 | None | code101 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5 Way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | | 3577606 | 130080 | None | code102 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall,10-12 way | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | | 3577607 | 130080 | None | code103 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall,16-18 way | Each | 405.0 | 405.0 | 1.0 | False | None | None | False | None | False | 405.0 | 0 | | 3577608 | 130080 | None | code104 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 | | 3577609 | 130080 | None | code105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4-5 Module | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | | 3577610 | 130080 | None | code106 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12 Module | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | | 3577611 | 130080 | None | code107 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module | Each | 457.0 | 457.0 | 1.0 | False | None | None | False | None | False | 457.0 | 0 | | 3577612 | 130080 | None | code108 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned | Each | 5992.0 | 5992.0 | 1.0 | False | None | None | False | None | False | 5992.0 | 0 | | 3577613 | 130080 | None | code109 | Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | Each | 1203.0 | 1203.0 | 1.0 | False | None | None | False | None | False | 1203.0 | 0 | | 3577614 | 130080 | None | code110 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 162.0 | 162.0 | 1.0 | False | None | None | False | None | False | 162.0 | 0 | | 3577615 | 130080 | None | code111 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition, LED square or round down light 10-12W | Each | 885.0 | 885.0 | 1.0 | False | None | None | False | None | False | 885.0 | 0 | | 3577616 | 130080 | None | code112 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast /extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x1' 34-22 W | Each | 3138.0 | 3138.0 | 1.0 | False | None | None | False | None | False | 3138.0 | 0 | | 3577617 | 130080 | None | code113 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast /extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' /1'x4' 34-36 W | Each | 3692.0 | 3692.0 | 1.0 | False | None | None | False | None | False | 3692.0 | 0 | | 3577618 | 130080 | None | code114 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9W, 6500K | Each | 154.0 | 154.0 | 1.0 | False | None | None | False | None | False | 154.0 | 0 | | 3577619 | 130080 | None | code115 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders. | Each | 122.0 | 122.0 | 4.0 | False | None | None | False | None | False | 488.0 | 0 | | 3577620 | 130080 | None | code116 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Lamp Holder | Each | 102.0 | 102.0 | 4.0 | False | None | None | False | None | False | 408.0 | 0 | | 3577621 | 130080 | None | code117 | Supplying And Fixing Metal Fan Box with Round Hook. | Each | 163.0 | 163.0 | 2.0 | False | None | None | False | None | False | 326.0 | 0 | | 3577622 | 130080 | None | code118 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | | 3577623 | 130080 | None | code119 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 | | 3577624 | 130080 | None | code120 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 | | 3577625 | 130080 | None | code121 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 1863.0 | 1863.0 | 1.0 | False | None | None | False | None | False | 1863.0 | 0 | | 3577626 | 130080 | None | code122 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32-40 A 2 pol | Each | 4277.0 | 4277.0 | 1.0 | False | None | None | False | None | False | 4277.0 | 0 | | 3577627 | 130080 | None | code123 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.PWD Electrical SR 2021-22, 5-32 DP | Each | 793.0 | 793.0 | 1.0 | False | None | None | False | None | False | 793.0 | 0 | | 3577628 | 130080 | None | code124 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. PWD Electrical SR 2021-22, 14SWG | Sq CM | 0.43 | 0.43 | 3600.0 | False | None | None | False | None | False | 1548.0 | 0 | | 3577629 | 130080 | None | code125 | Supplying .. A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete, 100 A 4 x 30 x 6 mm Aluminium Strips. | Mtr | 2465.0 | 2465.0 | 1.0 | False | None | None | False | None | False | 2465.0 | 0 | | 3577630 | 130080 | None | code126 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm. | Mtr | 395.0 | 395.0 | 3.0 | False | None | None | False | None | False | 1185.0 | 0 | | 3577631 | 130080 | None | code127 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | | 3577632 | 130080 | None | code128 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | | 3577633 | 130080 | None | code129 | Digging of Pit for providing GI Pipe type Earthing, Hard Soil, Bescom SR 2021-22 | No | 2990.0 | 2990.0 | 1.0 | False | None | None | False | None | False | 2990.0 | 0 | | 3577634 | 130080 | None | code130 | GI Grounding pipe, B Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg, Bescom SR 2021-22 | Each | 743.0 | 743.0 | 1.0 | False | None | None | False | None | False | 743.0 | 0 | | 3577635 | 130080 | None | code131 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg
each | Each | 676.0 | 676.0 | 1.0 | False | None | None | False | None | False | 676.0 | 0 | | 3577636 | 130080 | None | code132 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag.Bescom SR 2021-22 | Each | 310.0 | 310.0 | 1.0 | False | None | None | False | None | False | 310.0 | 0 | | 3577637 | 130080 | None | code133 | GI Wire 8 SWG | Kg | 77.85 | 77.85 | 3.0 | False | None | None | False | None | False | 233.55 | 0 | | 3577638 | 130080 | None | code134 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Hard Soil | Cum | 389.0 | 389.0 | 15.0 | False | None | None | False | None | False | 5835.0 | 0 | | 3577639 | 130080 | None | code135 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975,16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 183442.0 | 183442.0 | 0.04 | False | None | None | False | None | False | 7337.68 | 0 | | 3577640 | 130080 | None | code136 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff, Bescom SR 2021-22, 35 to 95 Sqmm | Km | 16159.0 | 16159.0 | 0.04 | False | None | None | False | None | False | 646.36 | 0 | | 3577641 | 130080 | None | code137 | GI Pipe B - Class as per IS-1239. GI Pipe - 50 mm Dia | Mtr | 295.0 | 295.0 | 6.0 | False | None | None | False | None | False | 1770.0 | 0 | | 3577642 | 130080 | None | code138 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.. 32 amps | Each | 401.0 | 401.0 | 1.0 | False | None | None | False | None | False | 401.0 | 0 | | 3577643 | 130080 | None | code139 | Providing and fixing C.P. brass stop cock (concealed) of standard design
and of approved make conforming to IS:8931. | Each | 725.0 | 725.0 | 2.0 | False | None | None | False | None | False | 1450.0 | 0 | | 3577644 | 130080 | None | code140 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.
Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :HDPE Grade PE80-PN6.0,110mm dia | Mtr | 469.0 | 469.0 | 6.0 | False | None | None | False | None | False | 2814.0 | 0 | | 3577645 | 130080 | None | code141 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 411.0 | 411.0 | 30.0 | False | None | None | False | None | False | 12330.0 | 0 | | 3577646 | 130080 | None | code142 | 1500 LPH SS Ro Plant 1 Raw water Pump 1HP Wilo/Lubi 12 High Pressure Pump 3 HP (4-16) Lyson 13 Dosing Pump 6 LPH Veritho 14 Pressure Vessel 1465T SS304-Imported 25 Multiport Valve 1" Real mount-TMF 26 Filter Media (Sand) Water wash 1507 Granular Activated Carbon Water wash 758 Flow Meters 2400lph panel mounted 29 SS filter Housing 20" x 3ele SS304 110 Jumbo Filter 2.5" Spun 311 Control Pannel Automatic Panel1:1 Proton 112 Membrane 80-40 Envo 213 Membrane Housing 8080:2E SS304-imported 114 Pressure Gauge 10 kg and 21kg Inline 315 Low/high Pressure Switch Danfor 216 Skid 1" SS 117 Plant Pipe SS304 1 lot18 Assembling 1 | Unit | 259000.0 | 259000.0 | 1.0 | False | None | None | False | None | False | 259000.0 | 0 |
| | 1721638068000 | 0 | None | None | Other Works | Rabkavi Banahatti cmc nagaraothana phase -4 | 16388661.74 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3577715 | 130089 | None | code01 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or each 5141 COMMON SCHEDULE OF RATES 152 2023-24 NO SOR CODE DESCRIPTIONS UNIT RATE Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M
(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. | No | 5446.64 | 5446.64 | 1.0 | False | None | None | False | None | False | 5446.64 | 0 | | 3577737 | 130089 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 18.6606 | False | None | None | False | None | False | 6977.011734 | 0 | | 3577782 | 130089 | None | code01 | Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. Cutting in Cement Concrete Road Surface | Cum | 1191.71 | 1191.71 | 26.8312 | False | None | None | False | None | False | 31975.009352 | 0 | | 3577850 | 130089 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 82.4652 | False | None | None | False | None | False | 30832.913628 | 0 | | 3577897 | 130089 | None | code01 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar | Cum | 1031.03 | 1031.03 | 21.6 | False | None | None | False | None | False | 22270.248 | 0 | | 3577716 | 130089 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 0 to 50MTR | Rmtr | 381.1 | 381.1 | 50.0 | False | None | None | False | None | False | 19055.0 | 0 | | 3577738 | 130089 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 3.8449 | False | None | None | False | None | False | 23717.919283 | 0 | | 3577783 | 130089 | None | code02 | Earth work excavatoin for water Supply & Sanitary lines, Electrical conduits either in pits or pipe line trenches (upto 600mm Trench width) as per drawing and technical specification, including setting out, construction of shoring, strutting, barricading, danger lighting, bracing, using sight rails & boning rods at every 100 mm whevere necessary removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench, including backfilling the excavated earth to the extent required and utilising the remaining available excavated earth locally for the work. in the following strata classifications by Mechanical Means. Ordinary / Hard Soil - (Depth upto 3m) | Cum | 269.86 | 269.86 | 160.9875 | False | None | None | False | None | False | 43444.08675 | 0 | | 3577851 | 130089 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 20.2328 | False | None | None | False | None | False | 124809.466376 | 0 | | 3577898 | 130089 | None | code02 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 1734.52 | 1734.52 | 8.25 | False | None | None | False | None | False | 14309.79 | 0 | | 3577717 | 130089 | None | code03 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 50 to 100MTR | Rmtr | 477.92 | 477.92 | 50.0 | False | None | None | False | None | False | 23896.0 | 0 | | 3577739 | 130089 | None | code03 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 6.7798 | False | None | None | False | None | False | 3310.033956 | 0 | | 3577784 | 130089 | None | code03 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 m | Mtr | 423.33 | 423.33 | 397.5 | False | None | None | False | None | False | 168273.675 | 0 | | 3577852 | 130089 | None | code03 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 25.7857 | False | None | None | False | None | False | 149024.069581 | 0 | | 3577899 | 130089 | None | code03 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 496.46 | 496.46 | 40.4352 | False | None | None | False | None | False | 20074.459392 | 0 | | 3577718 | 130089 | None | code04 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 100 to 150MTR | Rmtr | 507.79 | 507.79 | 50.0 | False | None | None | False | None | False | 25389.5 | 0 | | 3577740 | 130089 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 6.804 | False | None | None | False | None | False | 39322.56132 | 0 | | 3577785 | 130089 | None | code04 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 164.8 | 164.8 | 107.325 | False | None | None | False | None | False | 17687.16 | 0 | | 3577853 | 130089 | None | code04 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 78.1696 | False | None | None | False | None | False | 38163.962112 | 0 | | 3577900 | 130089 | None | code04 | Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge | Cum | 815.76 | 815.76 | 17.01 | False | None | None | False | None | False | 13876.0776 | 0 | | 3577719 | 130089 | None | code05 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe
grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Rmtr | 1990.99 | 1990.99 | 12.0 | False | None | None | False | None | False | 23891.88 | 0 | | 3577741 | 130089 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 9.7877 | False | None | None | False | None | False | 63381.327997 | 0 | | 3577786 | 130089 | None | code05 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification includingpremixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2635.77 | 2635.77 | 26.8312 | False | None | None | False | None | False | 70720.872024 | 0 | | 3577854 | 130089 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 34.7349 | False | None | None | False | None | False | 224929.665789 | 0 | | 3577901 | 130089 | None | code05 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 413.176 | False | None | None | False | None | False | 154482.37464 | 0 | | 3577720 | 130089 | None | code06 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (PartII) 1982 with all amendments | No | 154.5 | 154.5 | 3.0 | False | None | None | False | None | False | 463.5 | 0 | | 3577742 | 130089 | None | code06 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Footing @ 3% | Cum | 194.26 | 194.26 | 1.0125 | False | None | None | False | None | False | 196.68825 | 0 | | 3577787 | 130089 | None | code06 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (2nd Quarter Revision of Rates for cement related items M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 6565.22 | 6565.22 | 26.8312 | False | None | None | False | None | False | 176152.730864 | 0 | | 3577855 | 130089 | None | code06 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Footing @ 3% | Cum | 194.26 | 194.26 | 3.0374 | False | None | None | False | None | False | 590.045324 | 0 | | 3577902 | 130089 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 129.554 | False | None | None | False | None | False | 799175.87318 | 0 | | 3577721 | 130089 | None | code07 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge each 164 | No | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 | | 3577743 | 130089 | None | code07 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Columns @ 70% | Cum | 4532.92 | 4532.92 | 2.4318 | False | None | None | False | None | False | 11023.154856 | 0 | | 3577788 | 130089 | None | code07 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth SR 2023-24 | Cum | 373.89 | 373.89 | 78.5305 | False | None | None | False | None | False | 29361.768645 | 0 | | 3577856 | 130089 | None | code07 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Columns @ 70% | Cum | 4532.92 | 4532.92 | 5.0301 | False | None | None | False | None | False | 22801.040892 | 0 | | 3577903 | 130089 | None | code07 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 32.3784 | False | None | None | False | None | False | 187125.458472 | 0 | | 3577722 | 130089 | None | code08 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3.00 HP - 155 LPM @ 42 m = 3 STG Outlet Dia - 2.00” | No | 25064.02 | 25064.02 | 1.0 | False | None | None | False | None | False | 25064.02 | 0 | | 3577744 | 130089 | None | code08 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 2.1088 | False | None | None | False | None | False | 8193.447168 | 0 | | 3577789 | 130089 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates SR 2023-24 | Cum | 6168.67 | 6168.67 | 24.5438 | False | None | None | False | None | False | 151402.602746 | 0 | | 3577857 | 130089 | None | code08 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 12.4743 | False | None | None | False | None | False | 48467.146248 | 0 | | 3577904 | 130089 | None | code08 | Providing Coursed rubble masonry (first sort) with hard stone infoundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6816.54 | 6816.54 | 84.1833 | False | None | None | False | None | False | 573838.831782 | 0 | | 3577723 | 130089 | None | code09 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990with ISI Mark and as per its latest amendments. | Mtr | 190.55 | 190.55 | 140.0 | False | None | None | False | None | False | 26677.0 | 0 | | 3577745 | 130089 | None | code09 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Slab 50% | Cum | 3237.8 | 3237.8 | 3.725 | False | None | None | False | None | False | 12060.805 | 0 | | 3577790 | 130089 | None | code09 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5779.33 | 5779.33 | 23.9688 | False | None | None | False | None | False | 138523.604904 | 0 | | 3577858 | 130089 | None | code09 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Slab 50% | Cum | 3237.8 | 3237.8 | 14.193 | False | None | None | False | None | False | 45954.0954 | 0 | | 3577905 | 130089 | None | code09 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 | Cum | 507.79 | 507.79 | 1951.95 | False | None | None | False | None | False | 991180.6905 | 0 | | 3577724 | 130089 | None | code10 | Supply and delivery at site of brand new best make non-return valve as 50MM | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | | 3577746 | 130089 | None | code10 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 1.0766 | False | None | None | False | None | False | 99198.688386 | 0 | | 3577791 | 130089 | None | code10 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 59.7729 | False | None | None | False | None | False | 29182.325238 | 0 | | 3577859 | 130089 | None | code10 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 3.9752 | False | None | None | False | None | False | 366277.750392 | 0 | | 3577906 | 130089 | None | code10 | Loosening, leveling and Compacting original ground supportingembankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm, mixed with water at OMC andthen compacted by rolling so as to achieve minimum dry densityas given in Table 300-2 for embankment construction. | Cum | 108.15 | 108.15 | 67.8 | False | None | None | False | None | False | 7332.57 | 0 | | 3577725 | 130089 | None | code11 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e 90MM DAI | No | 9836.5 | 9836.5 | 1.0 | False | None | None | False | None | False | 9836.5 | 0 | | 3577747 | 130089 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 13.0768 | False | None | None | False | None | False | 107456.511712 | 0 | | 3577792 | 130089 | None | code11 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 44.2398 | False | None | None | False | None | False | 286479.691278 | 0 | | 3577860 | 130089 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 34.2792 | False | None | None | False | None | False | 281683.841328 | 0 | | 3577907 | 130089 | None | code11 | Construction of dry lean cement concrete Sub- base over aprepared sub-grade with coarse and fine aggregate conformingto IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradationafter blending to be as per table 600-1, cement content not to beless than 150 kg/ m3, optimum moisture content to be determinedduring trial length construction, concrete strength not to be lessthan 10 Mpa at 7 days, mixed in a batching plant, transportedto site, laid with a paver with electronic sensor, compacting with8-10 t vibratory roller, finishing and curing Construction of dry lean cement concrete | Cum | 5067.6 | 5067.6 | 32.0 | False | None | None | False | None | False | 162163.2 | 0 | | 3577726 | 130089 | None | code12 | Supplying, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveyingto work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 | Rmtr | 483.07 | 483.07 | 140.0 | False | None | None | False | None | False | 67629.8 | 0 | | 3577748 | 130089 | None | code12 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 14.259 | False | None | None | False | None | False | 14334.28752 | 0 | | 3577793 | 130089 | None | code12 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Footing @ 3% | Cum | 194.26 | 194.26 | 2.7 | False | None | None | False | None | False | 524.502 | 0 | | 3577861 | 130089 | None | code12 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 61.6769 | False | None | None | False | None | False | 62002.554032 | 0 | | 3577908 | 130089 | None | code12 | Providing and constructing un-reinforced plain cementconcrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork (steel channel,laying and fixing of 125 micron thick polythene film,wedges, steel plates including levelling the formwork asper drawing), spreading the concrete with shovels, rakes,compacted using needle, screed and plate vibrators andfinished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts,loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per thedirections of the Engineer-in-charge of the work. | Cum | 6956.62 | 6956.62 | 45.0 | False | None | None | False | None | False | 313047.9 | 0 | | 3577727 | 130089 | None | code13 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. | Rmtr | 41.2 | 41.2 | 140.0 | False | None | None | False | None | False | 5768.0 | 0 | | 3577749 | 130089 | None | code13 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 92.795 | False | None | None | False | None | False | 24372.60675 | 0 | | 3577794 | 130089 | None | code13 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Columns @ 70% | Cum | 4532.92 | 4532.92 | 5.0784 | False | None | None | False | None | False | 23019.980928 | 0 | | 3577862 | 130089 | None | code13 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 372.465 | False | None | None | False | None | False | 97827.93225 | 0 | | 3577909 | 130089 | None | code13 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 150.429 | False | None | None | False | None | False | 73442.44638 | 0 | | 3577728 | 130089 | None | code14 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6695.0 | 6695.0 | 1.0 | False | None | None | False | None | False | 6695.0 | 0 | | 3577750 | 130089 | None | code14 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 59.85 | False | None | None | False | None | False | 22870.4805 | 0 | | 3577795 | 130089 | None | code14 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 34.0192 | False | None | None | False | None | False | 132176.838912 | 0 | | 3577863 | 130089 | None | code14 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 202.86 | False | None | None | False | None | False | 77518.8918 | 0 | | 3577910 | 130089 | None | code14 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) SR 2023-24 | Cum | 6475.61 | 6475.61 | 208.474 | False | None | None | False | None | False | 1349996.31914 | 0 | | 3577729 | 130089 | None | code15 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. | Rmtr | 200.85 | 200.85 | 15.0 | False | None | None | False | None | False | 3012.75 | 0 | | 3577751 | 130089 | None | code15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 11.1232 | False | None | None | False | None | False | 12396.361472 | 0 | | 3577796 | 130089 | None | code15 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24 Slab 50% | Cum | 3237.8 | 3237.8 | 2.1 | False | None | None | False | None | False | 6799.38 | 0 | | 3577864 | 130089 | None | code15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 62.004 | False | None | None | False | None | False | 69100.97784 | 0 | | 3577911 | 130089 | None | code15 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24Footing @ 3% | Cum | 194.26 | 194.26 | 10.889 | False | None | None | False | None | False | 2115.29714 | 0 | | 3577730 | 130089 | None | code16 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | No | 3862.5 | 3862.5 | 1.0 | False | None | None | False | None | False | 3862.5 | 0 | | 3577752 | 130089 | None | code16 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 8.082 | False | None | None | False | None | False | 11587.64832 | 0 | | 3577797 | 130089 | None | code16 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 4.9023 | False | None | None | False | None | False | 451701.402633 | 0 | | 3577865 | 130089 | None | code16 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 11.178 | False | None | None | False | None | False | 16026.56928 | 0 | | 3577912 | 130089 | None | code16 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24Columns @ 70% | Cum | 4532.92 | 4532.92 | 13.869 | False | None | None | False | None | False | 62867.06748 | 0 | | 3577731 | 130089 | None | code17 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 249.26 | 249.26 | 2.2125 | False | None | None | False | None | False | 551.48775 | 0 | | 3577753 | 130089 | None | code17 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 7.875 | False | None | None | False | None | False | 2579.3775 | 0 | | 3577798 | 130089 | None | code17 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 32.6968 | False | None | None | False | None | False | 268680.722512 | 0 | | 3577866 | 130089 | None | code17 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 33.075 | False | None | None | False | None | False | 10833.3855 | 0 | | 3577913 | 130089 | None | code17 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24lintel ,Roof beam @ 60% | Cum | 3885.36 | 3885.36 | 67.3622 | False | None | None | False | None | False | 261726.397392 | 0 | | 3577732 | 130089 | None | code18 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6168.67 | 6168.67 | 1.9049 | False | None | None | False | None | False | 11750.699483 | 0 | | 3577754 | 130089 | None | code18 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 7.875 | False | None | None | False | None | False | 12880.665 | 0 | | 3577799 | 130089 | None | code18 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 48.027 | False | None | None | False | None | False | 48280.58256 | 0 | | 3577867 | 130089 | None | code18 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 33.075 | False | None | None | False | None | False | 54098.793 | 0 | | 3577914 | 130089 | None | code18 | Appendix 1 Additionalities for Formwork,Centering & Scaffolding Foundation, Sub structure of Cross drainages SR 2023-24Slab 50% | Cum | 3237.8 | 3237.8 | 6.625 | False | None | None | False | None | False | 21450.425 | 0 | | 3577733 | 130089 | None | code19 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6816.54 | 6816.54 | 2.3625 | False | None | None | False | None | False | 16104.07575 | 0 | | 3577755 | 130089 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 152.645 | False | None | None | False | None | False | 16980.2298 | 0 | | 3577800 | 130089 | None | code19 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 255.879 | False | None | None | False | None | False | 67206.61935 | 0 | | 3577868 | 130089 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 575.325 | False | None | None | False | None | False | 63999.153 | 0 | | 3577915 | 130089 | None | code19 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. SR 2023-24 | Tonne | 92140.71 | 92140.71 | 10.708 | False | None | None | False | None | False | 986642.72268 | 0 | | 3577734 | 130089 | None | code20 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 364.62 | 364.62 | 2.7 | False | None | None | False | None | False | 984.474 | 0 | | 3577756 | 130089 | None | code20 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 4.0 | False | None | None | False | None | False | 9603.72 | 0 | | 3577801 | 130089 | None | code20 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 204.019 | False | None | None | False | None | False | 77961.78047 | 0 | | 3577869 | 130089 | None | code20 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 18.0 | False | None | None | False | None | False | 43216.74 | 0 | | 3577916 | 130089 | None | code20 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 121.7965 | False | None | None | False | None | False | 1000843.25131 | 0 | | 3577735 | 130089 | None | code21 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm | Each | 16893.03 | 16893.03 | 1.0 | False | None | None | False | None | False | 16893.03 | 0 | | 3577757 | 130089 | None | code21 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 1.0 | False | None | None | False | None | False | 4980.05 | 0 | | 3577802 | 130089 | None | code21 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 69.7758 | False | None | None | False | None | False | 77762.338068 | 0 | | 3577870 | 130089 | None | code21 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 3.0 | False | None | None | False | None | False | 14940.15 | 0 | | 3577917 | 130089 | None | code21 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. DSR 2023-24 | Cum | 8457.33 | 8457.33 | 4.536 | False | None | None | False | None | False | 38362.44888 | 0 | | 3577736 | 130089 | None | code22 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. | Job | 1938.46 | 1938.46 | 1.0 | False | None | None | False | None | False | 1938.46 | 0 | | 3577758 | 130089 | None | code22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 1.0 | False | None | None | False | None | False | 3174.46 | 0 | | 3577803 | 130089 | None | code22 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 9.9 | False | None | None | False | None | False | 14194.224 | 0 | | 3577871 | 130089 | None | code22 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 3.0 | False | None | None | False | None | False | 9523.38 | 0 | | 3577918 | 130089 | None | code22 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1005.28 | 1005.28 | 82.983 | False | None | None | False | None | False | 83421.15024 | 0 | | 3577759 | 130089 | None | code23 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 11.0 | False | None | None | False | None | False | 10536.9 | 0 | | 3577804 | 130089 | None | code23 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 73.125 | False | None | None | False | None | False | 23951.3625 | 0 | | 3577872 | 130089 | None | code23 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 56.0 | False | None | None | False | None | False | 53642.4 | 0 | | 3577919 | 130089 | None | code23 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specificationsand as per directions of Engineer-in-charge.DSR 2023-24 | Sqm | 262.65 | 262.65 | 787.962 | False | None | None | False | None | False | 206958.2193 | 0 | | 3577760 | 130089 | None | code24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Nos | 304.88 | 304.88 | 40.0 | False | None | None | False | None | False | 12195.2 | 0 | | 3577805 | 130089 | None | code24 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 23.625 | False | None | None | False | None | False | 38641.995 | 0 | | 3577873 | 130089 | None | code24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Nos | 304.88 | 304.88 | 140.0 | False | None | None | False | None | False | 42683.2 | 0 | | 3577920 | 130089 | None | code24 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge DSR 2023-24 | Sqm | 382.13 | 382.13 | 971.5816 | False | None | None | False | None | False | 371270.476808 | 0 | | 3577761 | 130089 | None | code25 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 2.0 | False | None | None | False | None | False | 11622.52 | 0 | | 3577806 | 130089 | None | code25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 459.899 | False | None | None | False | None | False | 51159.16476 | 0 | | 3577874 | 130089 | None | code25 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 6.0 | False | None | None | False | None | False | 34867.56 | 0 | | 3577921 | 130089 | None | code25 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials,labour, curing, polishing complete as per specifications. | Sqm | 382.13 | 382.13 | 71.9315 | False | None | None | False | None | False | 27487.184095 | 0 | | 3577762 | 130089 | None | code26 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 | | 3577807 | 130089 | None | code26 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 12.0 | False | None | None | False | None | False | 28811.16 | 0 | | 3577875 | 130089 | None | code26 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 4000.0 | False | None | None | False | None | False | 37080.0 | 0 | | 3577922 | 130089 | None | code26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm DSR 2023-24 | Sqm | 1114.46 | 1114.46 | 113.82 | False | None | None | False | None | False | 126847.8372 | 0 | | 3577763 | 130089 | None | code27 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 2.0 | False | None | None | False | None | False | 453.2 | 0 | | 3577808 | 130089 | None | code27 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 3.0 | False | None | None | False | None | False | 14940.15 | 0 | | 3577876 | 130089 | None | code27 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 6.0 | False | None | None | False | None | False | 1359.6 | 0 | | 3577923 | 130089 | None | code27 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. DSR 2023-24 | Sqm | 1433.76 | 1433.76 | 118.884 | False | None | None | False | None | False | 170451.12384 | 0 | | 3577764 | 130089 | None | code28 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 5.0 | False | None | None | False | None | False | 1472.9 | 0 | | 3577809 | 130089 | None | code28 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 5.0 | False | None | None | False | None | False | 15872.3 | 0 | | 3577877 | 130089 | None | code28 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 27.0 | False | None | None | False | None | False | 7953.66 | 0 | | 3577924 | 130089 | None | code28 | Providing & fixing factory made PVC Door frame of size 50x47mm witha wall thickness of 5mm, made out of extruded 5mm rigid PVC foamsheet metered cut at corners & jointed 2 No.s of 150mm long bracketsof 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to thewall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 188.1 | False | None | None | False | None | False | 61610.274 | 0 | | 3577765 | 130089 | None | code29 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 2.52 | False | None | None | False | None | False | 21481.1856 | 0 | | 3577810 | 130089 | None | code29 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 50.0 | False | None | None | False | None | False | 47895.0 | 0 | | 3577878 | 130089 | None | code29 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 7.56 | False | None | None | False | None | False | 64443.5568 | 0 | | 3577925 | 130089 | None | code29 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos
of 75 mm Aluminium hinges. | Sqm | 1635.64 | 1635.64 | 51.975 | False | None | None | False | None | False | 85012.389 | 0 | | 3577766 | 130089 | None | code30 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 15.0 | False | None | None | False | None | False | 990.0 | 0 | | 3577811 | 130089 | None | code30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Nos | 304.88 | 304.88 | 104.0 | False | None | None | False | None | False | 31707.52 | 0 | | 3577879 | 130089 | None | code30 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required
pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of
Engineer-in-charge | Sqm | 824.0 | 824.0 | 240.0 | False | None | None | False | None | False | 197760.0 | 0 | | 3577926 | 130089 | None | code30 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 101779.45 | 101779.45 | 0.12 | False | None | None | False | None | False | 12213.534 | 0 | | 3577767 | 130089 | None | code31 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 15.0 | False | None | None | False | None | False | 1170.0 | 0 | | 3577812 | 130089 | None | code31 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 10.0 | False | None | None | False | None | False | 58112.6 | 0 | | 3577880 | 130089 | None | code31 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6458.1 | 6458.1 | 6.0 | False | None | None | False | None | False | 38748.6 | 0 | | 3577927 | 130089 | None | code31 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 5914.26 | 5914.26 | 3.78 | False | None | None | False | None | False | 22355.9028 | 0 | | 3577768 | 130089 | None | code32 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 15.0 | False | None | None | False | None | False | 390.0 | 0 | | 3577813 | 130089 | None | code32 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 5000.0 | False | None | None | False | None | False | 46350.0 | 0 | | 3577881 | 130089 | None | code32 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 45.0 | False | None | None | False | None | False | 2970.0 | 0 | | 3577928 | 130089 | None | code32 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 g/l, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two coats on new work to give an even shade after thoroughly brooming thesurface to remove all dirt, dust, mortar drops and foreign matter includingpreparing the surface even and sand paper smooth, cost of materials, labourcomplete as per specifications and as per directions of Engineer-in-charge.SR 2023-24 | Sqm | 82.4 | 82.4 | 429.46 | False | None | None | False | None | False | 35387.504 | 0 | | 3577769 | 130089 | None | code33 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 15.0 | False | None | None | False | None | False | 630.0 | 0 | | 3577814 | 130089 | None | code33 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 6.0 | False | None | None | False | None | False | 1359.6 | 0 | | 3577882 | 130089 | None | code33 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 30.0 | False | None | None | False | None | False | 2340.0 | 0 | | 3577929 | 130089 | None | code33 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. DSR 2023-24 | Sqm | 111.24 | 111.24 | 1199.073 | False | None | None | False | None | False | 133384.88052 | 0 | | 3577770 | 130089 | None | code34 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 10.0 | False | None | None | False | None | False | 630.0 | 0 | | 3577815 | 130089 | None | code34 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 21.0 | False | None | None | False | None | False | 6186.18 | 0 | | 3577883 | 130089 | None | code34 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 45.0 | False | None | None | False | None | False | 1170.0 | 0 | | 3577930 | 130089 | None | code34 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 118.45 | 118.45 | 28.8 | False | None | None | False | None | False | 3411.36 | 0 | | 3577771 | 130089 | None | code35 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 2.0 | False | None | None | False | None | False | 538.0 | 0 | | 3577816 | 130089 | None | code35 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 7.56 | False | None | None | False | None | False | 64443.5568 | 0 | | 3577884 | 130089 | None | code35 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 | | 3577931 | 130089 | None | code35 | Providing and laying flooring with burnt stone slabs 10 cms thick, rough chistle dressed on sand bed 7.5 cms to 8 cms thick and pointed with cement mortar 1:3, , including cost of materials, sand, labour, curing complete as per specifications | Sqm | 2441.1 | 2441.1 | 4.5 | False | None | None | False | None | False | 10984.95 | 0 | | 3577772 | 130089 | None | code36 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 2.0 | False | None | None | False | None | False | 748.0 | 0 | | 3577817 | 130089 | None | code36 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 45.0 | False | None | None | False | None | False | 2970.0 | 0 | | 3577885 | 130089 | None | code36 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 24.0 | False | None | None | False | None | False | 1512.0 | 0 | | 3577932 | 130089 | None | code36 | Providing and fixing white vitreous china water closet squatting pan Orissa pattern W.C. pan of size 580x440 mm DSR 2023-24 | Each | 2400.93 | 2400.93 | 29.0 | False | None | None | False | None | False | 69626.97 | 0 | | 3577773 | 130089 | None | code37 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 2.0 | False | None | None | False | None | False | 1110.0 | 0 | | 3577818 | 130089 | None | code37 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 45.0 | False | None | None | False | None | False | 3510.0 | 0 | | 3577886 | 130089 | None | code37 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 6.0 | False | None | None | False | None | False | 1614.0 | 0 | | 3577933 | 130089 | None | code37 | Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings :Flat back wash basin of size 630x450 mmSR 2023-24 | Each | 1015.58 | 1015.58 | 1.0 | False | None | None | False | None | False | 1015.58 | 0 | | 3577774 | 130089 | None | code38 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 3.0 | False | None | None | False | None | False | 477.0 | 0 | | 3577819 | 130089 | None | code38 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 45.0 | False | None | None | False | None | False | 1170.0 | 0 | | 3577887 | 130089 | None | code38 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 6.0 | False | None | None | False | None | False | 2244.0 | 0 | | 3577934 | 130089 | None | code38 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired :W.C. pan with ISI marked black solid plastic seat and lid | Each | 4980.05 | 4980.05 | 4.0 | False | None | None | False | None | False | 19920.2 | 0 | | 3577775 | 130089 | None | code39 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | | 3577820 | 130089 | None | code39 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 45.0 | False | None | None | False | None | False | 1890.0 | 0 | | 3577888 | 130089 | None | code39 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 6.0 | False | None | None | False | None | False | 3330.0 | 0 | | 3577935 | 130089 | None | code39 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15B mm C.P. brass pillar tapsDSR 2023-24 | Each | 3174.46 | 3174.46 | 8.0 | False | None | None | False | None | False | 25395.68 | 0 | | 3577776 | 130089 | None | code40 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 module | Each | 161.0 | 161.0 | 3.0 | False | None | None | False | None | False | 483.0 | 0 | | 3577821 | 130089 | None | code40 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | | 3577889 | 130089 | None | code40 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 9.0 | False | None | None | False | None | False | 1431.0 | 0 | | 3577936 | 130089 | None | code40 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent\ cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 957.9 | 957.9 | 210.0 | False | None | None | False | None | False | 201159.0 | 0 | | 3577777 | 130089 | None | code41 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | | 3577822 | 130089 | None | code41 | POINT WIRING USING COPPER WIRE WITHOUT SWITCHSupplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 6.0 | False | None | None | False | None | False | 1614.0 | 0 | | 3577890 | 130089 | None | code41 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 6.0 | False | None | None | False | None | False | 1062.0 | 0 | | 3577937 | 130089 | None | code41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | Mtr | 304.88 | 304.88 | 275.0 | False | None | None | False | None | False | 83842.0 | 0 | | 3577778 | 130089 | None | code42 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 6.0 | False | None | None | False | None | False | 612.0 | 0 | | 3577823 | 130089 | None | code42 | POINT WIRING USING COPPER WIRE WITHOUT SWITCHSupplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 6.0 | False | None | None | False | None | False | 2244.0 | 0 | | 3577891 | 130089 | None | code42 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 module | Each | 161.0 | 161.0 | 9.0 | False | None | None | False | None | False | 1449.0 | 0 | | 3577938 | 130089 | None | code42 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 188.49 | 188.49 | 450.0 | False | None | None | False | None | False | 84820.5 | 0 | | 3577779 | 130089 | None | code43 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 2.0 | False | None | None | False | None | False | 1942.0 | 0 | | 3577824 | 130089 | None | code43 | POINT WIRING USING COPPER WIRE WITHOUT SWITCHSupplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 6.0 | False | None | None | False | None | False | 3330.0 | 0 | | 3577892 | 130089 | None | code43 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 6.0 | False | None | None | False | None | False | 1050.0 | 0 | | 3577939 | 130089 | None | code43 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 5811.26 | 5811.26 | 18.0 | False | None | None | False | None | False | 104602.68 | 0 | | 3577780 | 130089 | None | code44 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | | 3577825 | 130089 | None | code44 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 9.0 | False | None | None | False | None | False | 1431.0 | 0 | | 3577893 | 130089 | None | code44 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 24.0 | False | None | None | False | None | False | 2448.0 | 0 | | 3577940 | 130089 | None | code44 | KSRB 13-13.34 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and but without fittings and the base support for tank | Ltr | 9.27 | 9.27 | 8500.0 | False | None | None | False | None | False | 78795.0 | 0 | | 3577781 | 130089 | None | code45 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 6.0 | False | None | None | False | None | False | 1956.0 | 0 | | 3577826 | 130089 | None | code45 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 6.0 | False | None | None | False | None | False | 1062.0 | 0 | | 3577894 | 130089 | None | code45 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 6.0 | False | None | None | False | None | False | 5826.0 | 0 | | 3577941 | 130089 | None | code45 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with allitting arrangements & all necessary accessories complete | Nos | 226.6 | 226.6 | 8.0 | False | None | None | False | None | False | 1812.8 | 0 | | 3577827 | 130089 | None | code46 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 module | Each | 161.0 | 161.0 | 9.0 | False | None | None | False | None | False | 1449.0 | 0 | | 3577895 | 130089 | None | code46 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 | | 3577942 | 130089 | None | code46 | 13.2 Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 294.58 | 294.58 | 40.0 | False | None | None | False | None | False | 11783.2 | 0 | | 3577828 | 130089 | None | code47 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 6.0 | False | None | None | False | None | False | 1050.0 | 0 | | 3577896 | 130089 | None | code47 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 24.0 | False | None | None | False | None | False | 7824.0 | 0 | | 3577943 | 130089 | None | code47 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. DSR 2023-24 | Sqm | 8524.28 | 8524.28 | 13.86 | False | None | None | False | None | False | 118146.5208 | 0 | | 3577829 | 130089 | None | code48 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 12.0 | False | None | None | False | None | False | 1224.0 | 0 | | 3577944 | 130089 | None | code48 | Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 522.21 | 522.21 | 11.5625 | False | None | None | False | None | False | 6038.053125 | 0 | | 3577830 | 130089 | None | code49 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 4.0 | False | None | None | False | None | False | 3884.0 | 0 | | 3577945 | 130089 | None | code49 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall20 mm dia | Mtr | 66.0 | 66.0 | 90.0 | False | None | None | False | None | False | 5940.0 | 0 | | 3577831 | 130089 | None | code50 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 | | 3577946 | 130089 | None | code50 | Electrical Works Concealed Conduit SystemSupplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures seen with fish wires where ever necessary with Groove Cutting in Wall25 mm dia | Mtr | 78.0 | 78.0 | 90.0 | False | None | None | False | None | False | 7020.0 | 0 | | 3577832 | 130089 | None | code51 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 16.0 | False | None | None | False | None | False | 5216.0 | 0 | | 3577947 | 130089 | None | code51 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 105.0 | False | None | None | False | None | False | 2730.0 | 0 | | 3577833 | 130089 | None | code52 | borewell Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or each 5141 COMMON SCHEDULE OF RATES 152 2023-24 NO SOR CODE DESCRIPTIONS UNIT RATE Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M
(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. | No | 5446.64 | 5446.64 | 1.0 | False | None | None | False | None | False | 5446.64 | 0 | | 3577948 | 130089 | None | code52 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2,5 sq.mm | Mtr | 42.0 | 42.0 | 75.0 | False | None | None | False | None | False | 3150.0 | 0 | | 3577834 | 130089 | None | code53 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 0 to 50MTR | Rmtr | 381.1 | 381.1 | 50.0 | False | None | None | False | None | False | 19055.0 | 0 | | 3577949 | 130089 | None | code53 | Using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | | 3577835 | 130089 | None | code54 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 50 to 100MTR | Rmtr | 477.92 | 477.92 | 50.0 | False | None | None | False | None | False | 23896.0 | 0 | | 3577950 | 130089 | None | code54 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletShort point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 14.0 | False | None | None | False | None | False | 3766.0 | 0 | | 3577836 | 130089 | None | code55 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 100 to 150MTR | Rmtr | 507.79 | 507.79 | 50.0 | False | None | None | False | None | False | 25389.5 | 0 | | 3577951 | 130089 | None | code55 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 374.0 | 374.0 | 8.0 | False | None | None | False | None | False | 2992.0 | 0 | | 3577837 | 130089 | None | code56 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., completedo ITEM NO.2 specification but borewell depth of 150 to 200 | Rmtr | 589.16 | 589.16 | 50.0 | False | None | None | False | None | False | 29458.0 | 0 | | 3577952 | 130089 | None | code56 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outletLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 12.0 | False | None | None | False | None | False | 6660.0 | 0 | | 3577838 | 130089 | None | code57 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe
grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Rmtr | 1990.99 | 1990.99 | 18.0 | False | None | None | False | None | False | 35837.82 | 0 | | 3577953 | 130089 | None | code57 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 Way | Each | 159.0 | 159.0 | 12.0 | False | None | None | False | None | False | 1908.0 | 0 | | 3577839 | 130089 | None | code58 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (PartII) 1982 with all amendments | No | 154.5 | 154.5 | 4.0 | False | None | None | False | None | False | 618.0 | 0 | | 3577954 | 130089 | None | code58 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 | | 3577840 | 130089 | None | code59 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge each 164 | No | 168.92 | 168.92 | 1.0 | False | None | None | False | None | False | 168.92 | 0 | | 3577955 | 130089 | None | code59 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 module | Each | 161.0 | 161.0 | 12.0 | False | None | None | False | None | False | 1932.0 | 0 | | 3577841 | 130089 | None | code60 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3.00 HP - 155 LPM @ 42 m = 3 STG Outlet Dia - 2.00” | No | 25064.02 | 25064.02 | 1.0 | False | None | None | False | None | False | 25064.02 | 0 | | 3577956 | 130089 | None | code60 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 8.0 | False | None | None | False | None | False | 1400.0 | 0 | | 3577842 | 130089 | None | code61 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990with ISI Mark and as per its latest amendments. | Mtr | 190.55 | 190.55 | 180.0 | False | None | None | False | None | False | 34299.0 | 0 | | 3577957 | 130089 | None | code61 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 102.0 | 102.0 | 16.0 | False | None | None | False | None | False | 1632.0 | 0 | | 3577843 | 130089 | None | code62 | Supply and delivery at site of brand new best make non-return valve as 50MM | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 | | 3577958 | 130089 | None | code62 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 971.0 | 971.0 | 6.0 | False | None | None | False | None | False | 5826.0 | 0 | | 3577844 | 130089 | None | code63 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ
e 90MM DAI | No | 9836.5 | 9836.5 | 1.0 | False | None | None | False | None | False | 9836.5 | 0 | | 3577959 | 130089 | None | code63 | Supplying and fixing miniature circuit breaker, on the existing MCB distribution board using necessary fixing materials and C type curve,indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K & complete wiring as required conforming to IEC 60898.6-32 Amps SP | Each | 415.0 | 415.0 | 4.0 | False | None | None | False | None | False | 1660.0 | 0 | | 3577845 | 130089 | None | code64 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations an rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 | Rmtr | 483.07 | 483.07 | 1.0125 | False | None | None | False | None | False | 489.108375 | 0 | | 3577960 | 130089 | None | code64 | Supplying&fixingofretrofittypeLEDbulb......WwithOPALacrylicdiffusercomprisingofLEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical conditionLED Bulbs 15W | Each | 326.0 | 326.0 | 44.0 | False | None | None | False | None | False | 14344.0 | 0 | | 3577846 | 130089 | None | code65 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with | Rmtr | 41.2 | 41.2 | 175.0 | False | None | None | False | None | False | 7210.0 | 0 | | 3577961 | 130089 | None | code65 | RO PLANT Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Sl. No.1.1, Page No.5 of PWD SR 2021-22 of Volume1. | Sqm | 93.73 | 93.73 | 25.0 | False | None | None | False | None | False | 2343.25 | 0 | | 3577847 | 130089 | None | code66 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and
erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6695.0 | 6695.0 | 1.0 | False | None | None | False | None | False | 6695.0 | 0 | | 3577962 | 130089 | None | code66 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Sl. No.1.14.1, Page No.8 of PWD SR 2021-22 of Volume1. | Cum | 105.06 | 105.06 | 25.758 | False | None | None | False | None | False | 2706.13548 | 0 | | 3577848 | 130089 | None | code67 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. | Rmtr | 200.85 | 200.85 | 20.0 | False | None | None | False | None | False | 4017.0 | 0 | | 3577963 | 130089 | None | code67 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Sl. No.4.1, Page No.5 of PWD SR 2021-22 of Volume2. | Sqm | 121.54 | 121.54 | 16.0 | False | None | None | False | None | False | 1944.64 | 0 | | 3577849 | 130089 | None | code68 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Nos | 3862.5 | 3862.5 | 1.0 | False | None | None | False | None | False | 3862.5 | 0 | | 3577964 | 130089 | None | code68 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand). Sl. No.5.4, Page No.9 of PWD SR 2021-22 of Volume2. | Cum | 6580.67 | 6580.67 | 5.9928 | False | None | None | False | None | False | 39436.639176 | 0 | | 3577965 | 130089 | None | code69 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Sl. No.2.1.2, Page No.15 of PWD SR 2021-22 of Volume1. Revised Rate W.E.F From 04-01-2023. | Cum | 5833.92 | 5833.92 | 3.393 | False | None | None | False | None | False | 19794.49056 | 0 | | 3577966 | 130089 | None | code70 | Providing and laying in position Reinforced cement concrete for allSub structures of building, Irrigation works, Sub structure works ofbridges, Drain works & other parallel works from 0.50m to 3.50 mheight. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other. appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement & formwork to be paidseparately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sl. No.2.4.3, Page No.17 of PWD SR 2021-22 of Volume1. Revised Rate W.E.F From 04-01-2023. | Cum | 6526.08 | 6526.08 | 2.7 | False | None | None | False | None | False | 17620.416 | 0 | | 3577967 | 130089 | None | code71 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Sl. No.2.5.2, Page No.17 of PWD SR 2021-22 of Volume1. Revised Rate W.E.F From 04-01-2023. | Cum | 7048.29 | 7048.29 | 6.455 | False | None | None | False | None | False | 45496.71195 | 0 | | 3577968 | 130089 | None | code72 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Sl. No.1.9, Page No.7 of PWD SR 2021-22 of Volume1. | Cum | 273.98 | 273.98 | 15.1376 | False | None | None | False | None | False | 4147.399648 | 0 | | 3577969 | 130089 | None | code73 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Footing. (8%) | Sqm | 522.08 | 522.08 | 2.7 | False | None | None | False | None | False | 1409.616 | 0 | | 3577970 | 130089 | None | code74 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Columns. (70%) | Sqm | 4933.8 | 4933.8 | 2.07 | False | None | None | False | None | False | 10212.966 | 0 | | 3577971 | 130089 | None | code75 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Lintel Beams and roof beams (60%) | Sqm | 4228.97 | 4228.97 | 0.6265 | False | None | None | False | None | False | 2649.449705 | 0 | | 3577972 | 130089 | None | code76 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Roof. (50%) | Sqm | 3524.14 | 3524.14 | 3.2725 | False | None | None | False | None | False | 11532.74815 | 0 | | 3577973 | 130089 | None | code77 | Appendix I Additionalities for Formwork, Centering & Scaffolding. Following additional percentage to be added to the finished rates of concrete of Buildings, Irrigation works, Water supply works, Roads & Bridges depending upon the type of structure. These percentages are worked out based on empirical mathematical approaches & exhaustive studies on the common standard sizes of the type of the structure of Buildings, Irrigation works, Bridges, Water works etc. The use rate of shuttering material is considered at 40 repetitions and type of material to be used is steel centering. Revision to 2021-22 VOL.1 COMMON SR- PAGE : 115 - 116 W.E.F 01.09.2022.Percentage on finished rate of concrete per m3. For Chejja (45%) | Sqm | 3171.73 | 3171.73 | 0.486 | False | None | None | False | None | False | 1541.46078 | 0 | | 3577974 | 130089 | None | code78 | 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Building | Tonne | 92140.71 | 92140.71 | 0.9363 | False | None | None | False | None | False | 86271.346773 | 0 | | 3577975 | 130089 | None | code79 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P. No.13, I. No.6.7, Volume-2,) Revised Rate W.E.F. 04-01-2023 | Cum | 8457.33 | 8457.33 | 4.4022 | False | None | None | False | None | False | 37230.858126 | 0 | | 3577976 | 130089 | None | code80 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.1.1. Page No.41 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2023 | Sqm | 262.65 | 262.65 | 12.5316 | False | None | None | False | None | False | 3291.42474 | 0 | | 3577977 | 130089 | None | code81 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.9, Page No.42 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2023 | Sqm | 382.13 | 382.13 | 66.4 | False | None | None | False | None | False | 25373.432 | 0 | | 3577978 | 130089 | None | code82 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.5.1, Page No.42 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2023 | Sqm | 376.98 | 376.98 | 10.62 | False | None | None | False | None | False | 4003.5276 | 0 | | 3577979 | 130089 | None | code83 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm ( Vol -2, I No - 9.22.2 , P No - 63, PWD SR - 2021-22 ) | Sqm | 1365.78 | 1365.78 | 14.411 | False | None | None | False | None | False | 19682.25558 | 0 | | 3577980 | 130089 | None | code84 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No.11.34A, Page No.85 of PWD SR 2021-22 of Volume2.Revised Rate W.E.F. 04-01-2022 | Kgs | 173.04 | 173.04 | 233.1 | False | None | None | False | None | False | 40335.624 | 0 | | 3577981 | 130089 | None | code85 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sl. No.12.90, Page No.112 of PWD SR 2021-22 of Volume2. | Sqm | 6936.02 | 6936.02 | 11.1 | False | None | None | False | None | False | 76989.822 | 0 | | 3577982 | 130089 | None | code86 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2742.89 | 2742.89 | 5.25 | False | None | None | False | None | False | 14400.1725 | 0 | | 3577983 | 130089 | None | code87 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.40, Page No.48 of PWD SR 2021-22 of Volume2. | Sqm | 118.45 | 118.45 | 16.35 | False | None | None | False | None | False | 1936.6575 | 0 | | 3577984 | 130089 | None | code88 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No.8.30, Page No.46 of PWD SR 2021-22 of Volume2. | Sqm | 179.22 | 179.22 | 66.4 | False | None | None | False | None | False | 11900.208 | 0 | | 3577985 | 130089 | None | code89 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Vol -2, I No - 8.33.1 , P No - 46, PWD SR - 2021-22 ) | Sqm | 162.74 | 162.74 | 10.62 | False | None | None | False | None | False | 1728.2988 | 0 | | 3577986 | 130089 | None | code90 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thick | Mtr | 66.0 | 66.0 | 25.0 | False | None | None | False | None | False | 1650.0 | 0 | | 3577987 | 130089 | None | code91 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box. | Point | 394.0 | 394.0 | 1.0 | False | None | None | False | None | False | 394.0 | 0 | | 3577988 | 130089 | None | code92 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22 Long point above 6m upto 10m from tapping point to out let via switch box | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 | | 3577989 | 130089 | None | code93 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Three outlet in a row, above 6m upto 10m from tapping point to out let via switche | Point | 1035.0 | 1035.0 | 2.0 | False | None | None | False | None | False | 2070.0 | 0 | | 3577990 | 130089 | None | code94 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical SR 2021-22, 1.5 mm2 | Mtr | 26.0 | 26.0 | 90.0 | False | None | None | False | None | False | 2340.0 | 0 | | 3577991 | 130089 | None | code95 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical SR 2021-22, 2.5 mm2 | Mtr | 42.0 | 42.0 | 90.0 | False | None | None | False | None | False | 3780.0 | 0 | | 3577992 | 130089 | None | code96 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. PWD Electrical SR 2021-22, 4 mm2 | Mtr | 63.0 | 63.0 | 45.0 | False | None | None | False | None | False | 2835.0 | 0 | | 3577993 | 130089 | None | code97 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654, 6A 3/5 Way | Each | 147.0 | 147.0 | 4.0 | False | None | None | False | None | False | 588.0 | 0 | | 3577994 | 130089 | None | code98 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 | | 3577995 | 130089 | None | code99 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket | Each | 236.0 | 236.0 | 8.0 | False | None | None | False | None | False | 1888.0 | 0 | | 3577996 | 130089 | None | code100 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-3 Way | Each | 138.0 | 138.0 | 1.0 | False | None | None | False | None | False | 138.0 | 0 | | 3577997 | 130089 | None | code101 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5 Way | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 | | 3577998 | 130089 | None | code102 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall,10-12 way | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | | 3577999 | 130089 | None | code103 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall,16-18 way | Each | 405.0 | 405.0 | 1.0 | False | None | None | False | None | False | 405.0 | 0 | | 3578000 | 130089 | None | code104 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 | | 3578001 | 130089 | None | code105 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4-5 Module | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 | | 3578002 | 130089 | None | code106 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12 Module | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | | 3578003 | 130089 | None | code107 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16-18 Module | Each | 457.0 | 457.0 | 1.0 | False | None | None | False | None | False | 457.0 | 0 | | 3578004 | 130089 | None | code108 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned | Each | 5992.0 | 5992.0 | 1.0 | False | None | None | False | None | False | 5992.0 | 0 | | 3578005 | 130089 | None | code109 | Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | Each | 1203.0 | 1203.0 | 1.0 | False | None | None | False | None | False | 1203.0 | 0 | | 3578006 | 130089 | None | code110 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 162.0 | 162.0 | 1.0 | False | None | None | False | None | False | 162.0 | 0 | | 3578007 | 130089 | None | code111 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition, LED square or round down light 10-12W | Each | 885.0 | 885.0 | 1.0 | False | None | None | False | None | False | 885.0 | 0 | | 3578008 | 130089 | None | code112 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast /extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x1' 34-22 W | Each | 3138.0 | 3138.0 | 1.0 | False | None | None | False | None | False | 3138.0 | 0 | | 3578009 | 130089 | None | code113 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast /extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' /1'x4' 34-36 W | Each | 3692.0 | 3692.0 | 1.0 | False | None | None | False | None | False | 3692.0 | 0 | | 3578010 | 130089 | None | code114 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9W, 6500K | Each | 154.0 | 154.0 | 1.0 | False | None | None | False | None | False | 154.0 | 0 | | 3578011 | 130089 | None | code115 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders. | Each | 122.0 | 122.0 | 4.0 | False | None | None | False | None | False | 488.0 | 0 | | 3578012 | 130089 | None | code116 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Lamp Holder | Each | 102.0 | 102.0 | 4.0 | False | None | None | False | None | False | 408.0 | 0 | | 3578013 | 130089 | None | code117 | Supplying And Fixing Metal Fan Box with Round Hook. | Each | 163.0 | 163.0 | 2.0 | False | None | None | False | None | False | 326.0 | 0 | | 3578014 | 130089 | None | code118 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | | 3578015 | 130089 | None | code119 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 | | 3578016 | 130089 | None | code120 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 2.0 | False | None | None | False | None | False | 630.0 | 0 | | 3578017 | 130089 | None | code121 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 1863.0 | 1863.0 | 1.0 | False | None | None | False | None | False | 1863.0 | 0 | | 3578018 | 130089 | None | code122 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32-40 A 2 pol | Each | 4277.0 | 4277.0 | 1.0 | False | None | None | False | None | False | 4277.0 | 0 | | 3578019 | 130089 | None | code123 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.PWD Electrical SR 2021-22, 5-32 DP | Each | 793.0 | 793.0 | 1.0 | False | None | None | False | None | False | 793.0 | 0 | | 3578020 | 130089 | None | code124 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. PWD Electrical SR 2021-22, 14SWG | Sq CM | 0.43 | 0.43 | 3600.0 | False | None | None | False | None | False | 1548.0 | 0 | | 3578021 | 130089 | None | code125 | Supplying .. A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic /FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete, 100 A 4 x 30 x 6 mm Aluminium Strips. | Mtr | 2465.0 | 2465.0 | 1.0 | False | None | None | False | None | False | 2465.0 | 0 | | 3578022 | 130089 | None | code126 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm. | Mtr | 395.0 | 395.0 | 3.0 | False | None | None | False | None | False | 1185.0 | 0 | | 3578023 | 130089 | None | code127 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 | | 3578024 | 130089 | None | code128 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 | | 3578025 | 130089 | None | code129 | Digging of Pit for providing GI Pipe type Earthing, Hard Soil, Bescom SR 2021-22 | No | 2990.0 | 2990.0 | 1.0 | False | None | None | False | None | False | 2990.0 | 0 | | 3578026 | 130089 | None | code130 | GI Grounding pipe, B Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg, Bescom SR 2021-22 | Each | 743.0 | 743.0 | 1.0 | False | None | None | False | None | False | 743.0 | 0 | | 3578027 | 130089 | None | code131 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg
each | Each | 676.0 | 676.0 | 1.0 | False | None | None | False | None | False | 676.0 | 0 | | 3578028 | 130089 | None | code132 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag.Bescom SR 2021-22 | Each | 310.0 | 310.0 | 1.0 | False | None | None | False | None | False | 310.0 | 0 | | 3578029 | 130089 | None | code133 | GI Wire 8 SWG | Kg | 77.85 | 77.85 | 3.0 | False | None | None | False | None | False | 233.55 | 0 | | 3578030 | 130089 | None | code134 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Hard Soil | Cum | 389.0 | 389.0 | 15.0 | False | None | None | False | None | False | 5835.0 | 0 | | 3578031 | 130089 | None | code135 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975,16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 183442.0 | 183442.0 | 0.04 | False | None | None | False | None | False | 7337.68 | 0 | | 3578032 | 130089 | None | code136 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff, Bescom SR 2021-22, 35 to 95 Sqmm | Km | 16159.0 | 16159.0 | 0.04 | False | None | None | False | None | False | 646.36 | 0 | | 3578033 | 130089 | None | code137 | GI Pipe B - Class as per IS-1239. GI Pipe - 50 mm Dia | Mtr | 295.0 | 295.0 | 6.0 | False | None | None | False | None | False | 1770.0 | 0 | | 3578034 | 130089 | None | code138 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.. 32 amps | Each | 401.0 | 401.0 | 1.0 | False | None | None | False | None | False | 401.0 | 0 | | 3578035 | 130089 | None | code139 | Providing and fixing C.P. brass stop cock (concealed) of standard design
and of approved make conforming to IS:8931. | Each | 725.0 | 725.0 | 2.0 | False | None | None | False | None | False | 1450.0 | 0 | | 3578036 | 130089 | None | code140 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.
Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 :HDPE Grade PE80-PN6.0,110mm dia | Mtr | 469.0 | 469.0 | 6.0 | False | None | None | False | None | False | 2814.0 | 0 | | 3578037 | 130089 | None | code141 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 411.0 | 411.0 | 30.0 | False | None | None | False | None | False | 12330.0 | 0 | | 3578038 | 130089 | None | code142 | 1500 LPH SS Ro Plant 1 Raw water Pump 1HP Wilo/Lubi 12 High Pressure Pump 3 HP (4-16) Lyson 13 Dosing Pump 6 LPH Veritho 14 Pressure Vessel 1465T SS304-Imported 25 Multiport Valve 1" Real mount-TMF 26 Filter Media (Sand) Water wash 1507 Granular Activated Carbon Water wash 758 Flow Meters 2400lph panel mounted 29 SS filter Housing 20" x 3ele SS304 110 Jumbo Filter 2.5" Spun 311 Control Pannel Automatic Panel1:1 Proton 112 Membrane 80-40 Envo 213 Membrane Housing 8080:2E SS304-imported 114 Pressure Gauge 10 kg and 21kg Inline 315 Low/high Pressure Switch Danfor 216 Skid 1" SS 117 Plant Pipe SS304 1 lot18 Assembling 1 | Unit | 259000.0 | 259000.0 | 1.0 | False | None | None | False | None | False | 259000.0 | 0 |
|
|
|---|