| 3572557 | 129827 | None | 1.13 V-I | Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/ Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work pth | Cum | 380.1 | 380.1 | 6.08 | False | None | None | False | None | False | 2311.008 | 0 |
| 3572558 | 129827 | None | 1.14.1 V-I | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete | Cum | 107.1 | 107.1 | 17.1 | False | None | None | False | None | False | 1831.41 | 0 |
| 3572559 | 129827 | None | 1.23 V-I | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 2816.1 | 2816.1 | 2.59 | False | None | None | False | None | False | 7293.699 | 0 |
| 3572560 | 129827 | None | 2.1.2 V-I | Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete the work as per technical specifications. | Cum | 5947.2 | 5947.2 | 5.88 | False | None | None | False | None | False | 34969.536 | 0 |
| 3572561 | 129827 | None | 5.4 V-II | Providing Size Stone masonry with hard stone in foundation & plinth with cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 6.01 | False | None | None | False | None | False | 40317.7845 | 0 |
| 3572562 | 129827 | None | 8.19.2 V-II | Providing Raised and cut pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.) | Cum | 486.15 | 486.15 | 8.72 | False | None | None | False | None | False | 4239.228 | 0 |
| 3572563 | 129827 | None | 2.2.1 V-I | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7129.46 | 7129.46 | 4.14 | False | None | None | False | None | False | 29515.9644 | 0 |
| 3572564 | 129827 | None | 2.3.1 V-I | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications | Cum | 9958.73 | 9958.73 | 2.0 | False | None | None | False | None | False | 19917.46 | 0 |
| 3572565 | 129827 | None | 1.9 V-I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 7.99 | False | None | None | False | None | False | 2231.607 | 0 |
| 3572566 | 129827 | None | 2.5.1 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11834.55 | 11834.55 | 1.28 | False | None | None | False | None | False | 15148.224 | 0 |
| 3572567 | 129827 | None | 6.33 V-II | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1292.55 | 1292.55 | 81.87 | False | None | None | False | None | False | 105821.0685 | 0 |
| 3572568 | 129827 | None | 2.5.1 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical pecifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.25 | False | None | None | False | None | False | 1740.375 | 0 |
| 3572569 | 129827 | None | 2.5.1 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 0.88 | False | None | None | False | None | False | 9801.792 | 0 |
| 3572570 | 129827 | None | 2.5.1 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11138.4 | 11138.4 | 1.65 | False | None | None | False | None | False | 18378.36 | 0 |
| 3572571 | 129827 | None | 2.5.1 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 4.62 | False | None | None | False | None | False | 48243.195 | 0 |
| 3572572 | 129827 | None | 2.5.1 V-1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical pecifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.31 | False | None | None | False | None | False | 2158.065 | 0 |
| 3572573 | 129827 | None | 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.a)Buildings | Tonne | 93929.85 | 93929.85 | 1.1063 | False | None | None | False | None | False | 103914.593055 | 0 |
| 3572574 | 129827 | None | 8.5.2 V-II | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 366.45 | 366.45 | 39.42 | False | None | None | False | None | False | 14445.459 | 0 |
| 3572575 | 129827 | None | 8.8 V-II | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finishedwith a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off cornerswherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 389.55 | 389.55 | 86.25 | False | None | None | False | None | False | 33598.6875 | 0 |
| 3572576 | 129827 | None | 9.4 V-II | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge | Cum | 6999.3 | 6999.3 | 0.6 | False | None | None | False | None | False | 4199.58 | 0 |
| 3572577 | 129827 | None | 11.11.1 V-II | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) | Kg | 155.4 | 155.4 | 34.02 | False | None | None | False | None | False | 5286.708 | 0 |
| 3572578 | 129827 | None | 11.30.1 V-II | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge | Sqm | 957.6 | 957.6 | 1.62 | False | None | None | False | None | False | 1551.312 | 0 |
| 3572579 | 129827 | None | 11.5.1 V-II | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4701.9 | 4701.9 | 3.78 | False | None | None | False | None | False | 17773.182 | 0 |
| 3572580 | 129827 | None | 12.54 V-II | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Mtr | 333.9 | 333.9 | 22.8 | False | None | None | False | None | False | 7612.92 | 0 |
| 3572581 | 129827 | None | 12.55 .1 V-II | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelam | m | 2484.3 | 2484.3 | 6.3 | False | None | None | False | None | False | 15651.09 | 0 |
| 3572582 | 129827 | None | 8.4 V-II | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 11.88 | False | None | None | False | None | False | 1434.51 | 0 |
| 3572583 | 129827 | None | 14.32.2 V-II | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm | Each | 1068.9 | 1068.9 | 4.0 | False | None | None | False | None | False | 4275.6 | 0 |
| 3572584 | 129827 | None | 22.49 V-II | Providing & fixing upvc ventilator with Exhaust Turbo speed fan with 5 blades (300mm x 300 mm & above sized fan) with copper motor having mounting arrangements as per direction of Engineer in charge of work | Each | 2047.5 | 2047.5 | 6.0 | False | None | None | False | None | False | 12285.0 | 0 |
| 3572585 | 129827 | None | 1PWD | Monoblock Single Phase Motor 0.5/0.37 | Each | 7271.25 | 7271.25 | 1.0 | False | None | None | False | None | False | 7271.25 | 0 |
| 3572586 | 129827 | None | 13.31.3 V-II | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | Rmtr | 333.9 | 333.9 | 60.0 | False | None | None | False | None | False | 20034.0 | 0 |
| 3572587 | 129827 | None | 13.2.1 V-II | Providing and fixing brass bib cock of approved quality 15mm nominal bore | Each | 300.3 | 300.3 | 15.0 | False | None | None | False | None | False | 4504.5 | 0 |
| 3572588 | 129827 | None | 10.1.7 V-II | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Rmtr | 411.0 | 411.0 | 42.0 | False | None | None | False | None | False | 17262.0 | 0 |
| 3572589 | 129827 | None | 9.12.2 V-II | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 19.52 | False | None | None | False | None | False | 23467.92 | 0 |
| 3572590 | 129827 | None | 20.44.1 V-II | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge Long pattern W.C Pan of size 580x440 mm | Each | 2930.55 | 2930.55 | 4.0 | False | None | None | False | None | False | 11722.2 | 0 |
| 3572591 | 129827 | None | 14.7.7 V-II | White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap | Each | 2203.95 | 2203.95 | 4.0 | False | None | None | False | None | False | 8815.8 | 0 |
| 3572592 | 129827 | None | 14.23 V-II | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. | Each | 1211.7 | 1211.7 | 3.0 | False | None | None | False | None | False | 3635.1 | 0 |
| 3572593 | 129827 | None | 1010 | Vitreous china squatting plate urinal | Each | 1155.0 | 1155.0 | 3.0 | False | None | None | False | None | False | 3465.0 | 0 |
| 3572594 | 129827 | None | 410 | Granite of any colour, 18 mm thick (slab area above 0.50 m2) | Sqm | 1785.0 | 1785.0 | 5.04 | False | None | None | False | None | False | 8996.4 | 0 |
| 3572595 | 129827 | None | 9.39 V-II | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1573.95 | 1573.95 | 71.65 | False | None | None | False | None | False | 112773.5175 | 0 |
| 3572596 | 129827 | None | 8.25 V-II | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 53.54 | False | None | None | False | None | False | 7701.729 | 0 |
| 3572597 | 129827 | None | 8.51 V-II | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 53.54 | False | None | None | False | None | False | 5621.7 | 0 |
| 3572598 | 129827 | None | 8.31 V-II | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 186.9 | 186.9 | 86.88 | False | None | None | False | None | False | 16237.872 | 0 |
| 3572599 | 129827 | None | 11.28 V-II | Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railingwith necessary accessories & stainless steel dash fasteners, stainlesssteel bolts etc., of required size, on the top of the floor or the side of waistslab with suitable arrangement as per approval of Engineer-in- charge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 593.25 | 593.25 | 43.69 | False | None | None | False | None | False | 25919.0925 | 0 |
| 3572600 | 129827 | None | 13.47 V-II | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter | Rmtr | 206.85 | 206.85 | 15.6 | False | None | None | False | None | False | 3226.86 | 0 |
| 3572601 | 129827 | None | 9.4 V-II | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge | Cum | 6999.3 | 6999.3 | 1.41 | False | None | None | False | None | False | 9869.013 | 0 |
| 3572602 | 129827 | None | 1.9.1 PWD ELE VI | Supplying PVC flexible conduit pipe....mm dia fixing on surface over inverted tapered wooden plugs orphillplugs orrawlplug sand clamped using heavy gauge saddle satan interval of 300 mmusing NF screws and on either end of the pipe terminated completely.20MM | m | 19.0 | 19.0 | 100.0 | False | None | None | False | None | False | 1900.0 | 0 |
| 3572603 | 129827 | None | 2.3.2 PWD ELE VI | Wiring for lighting/power circuit using one of FRLSPVC insulated 1100Vgrade,multistrand copper wire withlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5MM2 | m | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
| 3572604 | 129827 | None | 2.3.3 PWD ELE VI | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5MM2 | m | 42.0 | 42.0 | 100.0 | False | None | None | False | None | False | 4200.0 | 0 |
| 3572605 | 129827 | None | 2.3.4 PWD ELE VI | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100Vgrade,multi strand copper wire with lowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4MM2 | m | 63.0 | 63.0 | 100.0 | False | None | None | False | None | False | 6300.0 | 0 |
| 3572606 | 129827 | None | 1.7.1 PWD ELE VI | Extra for Groove cutting n brickwall/Ccfloor tothesuitabledepth forconcealingof Conduit/GI pipe and plastering,finishinguptowall surface complete upto 50 mm conduit in brick wall | m | 29.0 | 29.0 | 100.0 | False | None | None | False | None | False | 2900.0 | 0 |
| 3572607 | 129827 | None | 2.1.1 PWD ELE VI | Supplying and wiring adopting loopsystem in existing PVC Conduit/casing capping using2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLS multistrand PVC insulated copperwire(confirmingtoIS 694:and latestamendments) with a6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox, the other end of the wires shall be terminatedwithsufficientlooselengthinawood/PVCroundblock.completeforeach outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 6.0 | False | None | None | False | None | False | 1710.0 | 0 |
| 3572608 | 129827 | None | 2.1.2 PWD ELE VI | Supplying and wiring adopting loopsystem in existing PVC Conduit/casingcappingusing2x1.5Sqmm(Phase&Neutral)&1x1.0sqmm(Earthwire)FRLSmultistrand PVC insulated copperwire(confirmingtoIS 694:and latestamendments) with a6Amps flush type SP control switchshallbe fixedonthe existing plasticsheet/gangbox,the other endofthewiresshallbeterminatedwithsufficientlooselengthinawood/PVCroundblock.complete for each outlet. Medium point above3Mtrupto6Mtrfromtappingpointtooutletviaswitchh | Point | 394.0 | 394.0 | 5.0 | False | None | None | False | None | False | 1970.0 | 0 |
| 3572609 | 129827 | None | 3.8 PWD ELE VI | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches,regulatorsetc,andfixingonexistingwoodenormetal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 9600.0 | False | None | None | False | None | False | 3936.0 | 0 |
| 3572610 | 129827 | None | 3.14.1 PWD ELE VI | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board 6A SP Switch | No | 55.0 | 55.0 | 7.0 | False | None | None | False | None | False | 385.0 | 0 |
| 3572611 | 129827 | None | 3.14.2 PWD ELE VI | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Two Way Switch | No | 70.0 | 70.0 | 3.0 | False | None | None | False | None | False | 210.0 | 0 |
| 3572612 | 129827 | None | 5.19.1 PWD ELE VI | Supplying and fixing regular MCB distribution boards on wall/oodboard/flushmounting using required clamps,bolts,nutsetc.,with provision forfixing suitable type capacity MCB'ssinglephase/3phase/single door with powder coated painting Made out of 14SWGMS enclosure.I - Single Door (1200 mm) Regular model 4 Way SP & N | No | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 |
| 3572613 | 129827 | None | 11.11.7 PWD ELE VI | Supplying & fixing of retrofit type-LED bulb......Wwith OPAL acrylic diffuser comprising of LEDsourcewithCCT6500degreeK,CRI70%.efficacy80lumenperW,life25000burninghoursandCompliancetoIS10322/IEC60598,LM79&LM80.TheLEDaredrivenbyHFelectronicdriverintegratedinthesystem,withPF0.95,powerlossshould5%oflampWage.,shortcircuit&opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical condition.18W, 6500K | No | 426.0 | 426.0 | 10.0 | False | None | None | False | None | False | 4260.0 | 0 |
| 3572614 | 129827 | None | 20.50 V-II | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications | Sqm | 13.65 | 13.65 | 711.32 | False | None | None | False | None | False | 9709.518 | 0 |
| 3572615 | 129827 | None | 8.25 V-II | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 143.85 | 143.85 | 711.32 | False | None | None | False | None | False | 102323.382 | 0 |
| 3572616 | 129827 | None | 20.50 V-II | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications | Sqm | 13.65 | 13.65 | 519.31 | False | None | None | False | None | False | 7088.5815 | 0 |
| 3572617 | 129827 | None | 8.73.1 V-II | Finishing walls with textured exterior paint of required shade :Old work (Two coats on existing cement paint surface applied @ 3.28 l/10 m² including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 226.8 | 226.8 | 519.31 | False | None | None | False | None | False | 117779.508 | 0 |
| 3572618 | 129827 | None | 15.1 V-II | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification | Sqm | 857.85 | 857.85 | 306.6 | False | None | None | False | None | False | 263016.81 | 0 |