3572743 | 129837 | None | 1.12PWD | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 95.0 | 95.0 | 25.0 | False | None | None | False | None | False | 2375.0 | 0 |
3572744 | 129837 | None | 1.14.1PWD | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 102.0 | 102.0 | 45.11 | False | None | None | False | None | False | 4601.22 | 0 |
3572745 | 129837 | None | 2.1.2PWD | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 14.07 | False | None | None | False | None | False | 79692.48 | 0 |
3572746 | 129837 | None | 5.4PWD | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6389.0 | 6389.0 | 8.92 | False | None | None | False | None | False | 56989.88 | 0 |
3572747 | 129837 | None | 2.2.2PWD | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with 20% partial replacement with Recycled concrete aggregate | Cum | 6747.84 | 6747.84 | 5.36 | False | None | None | False | None | False | 36168.4224 | 0 |
3572748 | 129837 | None | 2.1.4PWD | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 2.86 | False | None | None | False | None | False | 17780.62 | 0 |
3572749 | 129837 | None | 1.9PWD | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 60.54 | False | None | None | False | None | False | 16103.64 | 0 |
3572750 | 129837 | None | 2.5.1PWD | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9945.0 | 9945.0 | 3.17 | False | None | None | False | None | False | 31525.65 | 0 |
3572751 | 129837 | None | 2.5.1PWD | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11271.0 | 11271.0 | 2.96 | False | None | None | False | None | False | 33362.16 | 0 |
3572752 | 129837 | None | 2.5.1PWD | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10608.0 | 10608.0 | 6.28 | False | None | None | False | None | False | 66618.24 | 0 |
3572753 | 129837 | None | 2.5.1PWD | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9945.0 | 9945.0 | 11.62 | False | None | None | False | None | False | 115560.9 | 0 |
3572754 | 129837 | None | 2.5.1PWD | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9613.5 | 9613.5 | 0.22 | False | None | None | False | None | False | 2114.97 | 0 |
3572755 | 129837 | None | 2.11APWD | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 89457.0 | 89457.0 | 2.09 | False | None | None | False | None | False | 186965.13 | 0 |
3572756 | 129837 | None | 6.7PWD | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8211.0 | 8211.0 | 23.56 | False | None | None | False | None | False | 193451.16 | 0 |
3572757 | 129837 | None | 11.5.1PWD | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Sqm | 4478.0 | 4478.0 | 2.52 | False | None | None | False | None | False | 11284.56 | 0 |
3572758 | 129837 | None | 11.11.1PWD | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 148.0 | 148.0 | 216.0 | False | None | None | False | None | False | 31968.0 | 0 |
3572759 | 129837 | None | 8.7PWD | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 366.0 | 366.0 | 96.76 | False | None | None | False | None | False | 35414.16 | 0 |
3572760 | 129837 | None | 8.9PWD | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 385.0 | 385.0 | 151.94 | False | None | None | False | None | False | 58496.9 | 0 |
3572761 | 129837 | None | 9.17.2PWD | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1175.0 | 1175.0 | 89.32 | False | None | None | False | None | False | 104951.0 | 0 |
3572762 | 129837 | None | 2.1.4PWD | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 0.95 | False | None | None | False | None | False | 5906.15 | 0 |
3572763 | 129837 | None | 8.51PWD | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.0 | 100.0 | 181.16 | False | None | None | False | None | False | 18116.0 | 0 |
3572764 | 129837 | None | 8.25PWD | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 181.16 | False | None | None | False | None | False | 24818.92 | 0 |
3572765 | 129837 | None | 8.84PWD | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. | Sqm | 475.0 | 475.0 | 4.0 | False | None | None | False | None | False | 1900.0 | 0 |
3572766 | 129837 | None | 8.32PWD | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 156.0 | 156.0 | 135.14 | False | None | None | False | None | False | 21081.84 | 0 |
3572767 | 129837 | None | 13.48PWD | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | Mtr | 291.0 | 291.0 | 7.0 | False | None | None | False | None | False | 2037.0 | 0 |
3572768 | 129837 | None | 1.3.1PWD | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2mm thick | Mtr | 68.0 | 68.0 | 20.0 | False | None | None | False | None | False | 1360.0 | 0 |
3572769 | 129837 | None | 1.3.2PWD | Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2mm thick | Mtr | 79.0 | 79.0 | 15.0 | False | None | None | False | None | False | 1185.0 | 0 |
3572770 | 129837 | None | 3.4.6PWD | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way | Each | 319.0 | 319.0 | 6.0 | False | None | None | False | None | False | 1914.0 | 0 |
3572771 | 129837 | None | 3.5.6PWD | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 344.0 | 344.0 | 6.0 | False | None | None | False | None | False | 2064.0 | 0 |
3572772 | 129837 | None | 2.1.1PWD | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
3572773 | 129837 | None | 2.1.2PWD | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 |
3572774 | 129837 | None | 2.1.3PWD | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
3572775 | 129837 | None | 3.14.5PWD | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bakelite Ceiling Rose | No | 78.0 | 78.0 | 1.0 | False | None | None | False | None | False | 78.0 | 0 |
3572776 | 129837 | None | 3.14.7PWD | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Batten Holder | No | 74.0 | 74.0 | 4.0 | False | None | None | False | None | False | 296.0 | 0 |
3572777 | 129837 | None | 3.6.1PWD | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
3572778 | 129837 | None | 3.6.3PWD | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 |
3572779 | 129837 | None | 3.6.4PWD | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 |
3572780 | 129837 | None | 3.6.9PWD | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 |
3572781 | 129837 | None | 5.7.2PWD | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32 A | Each | 241.0 | 241.0 | 1.0 | False | None | None | False | None | False | 241.0 | 0 |
3572782 | 129837 | None | 6.3.2PWD | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model | Each | 3031.0 | 3031.0 | 1.0 | False | None | None | False | None | False | 3031.0 | 0 |
3572783 | 129837 | None | 5.46.2PWD | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 40 A SP | Each | 300.0 | 300.0 | 1.0 | False | None | None | False | None | False | 300.0 | 0 |
3572784 | 129837 | None | 1.6.1PWD | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 12" x 3" (300 x 300 x 76 mm) | Each | 120.0 | 120.0 | 1.0 | False | None | None | False | None | False | 120.0 | 0 |
3572785 | 129837 | None | 12.26PWD | Supplying of box fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube 1 x 4' Tube light fitting. | Each | 461.0 | 461.0 | 1.0 | False | None | None | False | None | False | 461.0 | 0 |
3572786 | 129837 | None | 12.2PWD | Supplying and fixing of T8 36/40W Fluorescent Tube with 36W power consumption with initial lumen of 2750 (3000 deg K / 4000 deg K) with rated avg life of greater than 10000 hrs. Operating voltage range from 180V to 265V. 50Hz AC power Supply | No | 63.0 | 63.0 | 2.0 | False | None | None | False | None | False | 126.0 | 0 |