createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721627858289
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd387600.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-07-2024 16:00:00
tenderQueryClose25-07-2024 11:00:00
technicalBidOpen31-07-2024 16:30:00
publishedDate22-07-2024 13:56:28
publishedByPostPWD_EE_DIV_RCR
publishedByUserKPE15695 - K SHANKAR
bidValidityPeriod90
noOfCalls2
preBidMeetingDate23-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonChandrashekar TA
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08532225778
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1721627858291
version11
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT9592/CALL-2
titleCONSTRUCTION OF NEW GOVT HIGH SCHOOL BUILDING AND TOILET AT GARALDINNI VILLAGE AND CONSTRUCTION OF 3 CLASS ROOM TO GOVT HIGHER PRIMARY SCHOOL AT MAMDAPUR VILLAGE IN RAICHUR TALUKA, RAICHUR DISTRICT. UNDER KKRDB - MACRO (GENERAL) FOR THE YEAR 2023-24 (Work code RCH2317133389).
descriptionCONSTRUCTION OF NEW GOVT HIGH SCHOOL BUILDING AND TOILET AT GARALDINNI VILLAGE AND CONSTRUCTION OF 3 CLASS ROOM TO GOVT HIGHER PRIMARY SCHOOL AT MAMDAPUR VILLAGE IN RAICHUR TALUKA, RAICHUR DISTRICT. UNDER KKRDB - MACRO (GENERAL) FOR THE YEAR 2023-24 (Work code RCH2317133389).
categoryWORKS
categoryTextWorks
ecv25839556.68
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1695
locationNamePWD Division Office Raichuru
provisionalAmount30800000.0
groupOverheadTotal0.0
fileNumberAEE/PWD/SDR/SCHOOL-BUILDING/KKRDB/MACRO/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17216278580001NoneNoneBuildingsGaraldinni School Building Ground Floor9265246.84
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3573787129911NoneVOL I for the year 2023-24. I. No. 1.12 P.No. 08)Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (PWD CSR VOL I for the year 2023-24. I. No. 1.12 P.No. 08)Cum99.7599.75315.0FalseNoneNoneFalseNoneFalse31421.250
3573788129911NoneVOL I 2023-24. I. No. 1.14.1 P.No. 08 )Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR VOL I for the year 2023-24. I. No. 1.14.1 P.No. 08 )Cum107.1107.1640.18FalseNoneNoneFalseNoneFalse68563.2780
3573789129911NoneVOL I for the year 2023-24. I. No. 1.4.1 P.No. 05)Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD CSR VOL I for the year 2023-24. I. No. 1.4.1 P.No. 05)Cum254.1254.118.09FalseNoneNoneFalseNoneFalse4596.6690
3573790129911NoneVOL I for the year 2023-24. I. No. 1.23 P.No. 11)Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. (PWD CSR VOL I for the year 2023-24. I. No. 1.23 P.No. 11)Cum2816.12816.191.46FalseNoneNoneFalseNoneFalse257560.5060
3573791129911NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6527.856527.851.43FalseNoneNoneFalseNoneFalse9334.82550
3573792129911NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3916.713916.711.43FalseNoneNoneFalseNoneFalse5600.89530
3573793129911NoneVOL I for the year 2023-24. I. No. 2.1.3 P.No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15)Cum6288.456288.4594.18FalseNoneNoneFalseNoneFalse592246.2210
3573794129911NoneVOL I for the year 2023-24. I. No. 1.11 P.No. 07)Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. (PWD CSR VOL I for the year 2023-24. I. No. 1.11 P.No. 07)Cum454.65454.65859.72FalseNoneNoneFalseNoneFalse390871.6980
3573795129911NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.897.6FalseNoneNoneFalseNoneFalse649313.280
3573796129911NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for isolated footings 8%. (PWD CSR VOL I for the year 2023-24. Sl. No. 1(b) P.No. 111)Cum532.22532.2297.6FalseNoneNoneFalseNoneFalse51944.6720
3573797129911NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.85.4FalseNoneNoneFalseNoneFalse35925.120
3573798129911NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum4656.964656.965.4FalseNoneNoneFalseNoneFalse25147.5840
3573799129911NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.834.95FalseNoneNoneFalseNoneFalse232515.360
3573800129911NoneVOL I for the year 2023-24. Sl. No. 2 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings 50%. (PWD CSR VOL I for the year 2023-24. Sl. No. 2 P.No. 111)Cum3326.43326.434.95FalseNoneNoneFalseNoneFalse116257.680
3573801129911NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.1514.73FalseNoneNoneFalseNoneFalse105837.25950
3573802129911NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5029.65029.614.73FalseNoneNoneFalseNoneFalse74086.0080
3573803129911NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.57185.55.72FalseNoneNoneFalseNoneFalse41101.060
3573804129911NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.095.72FalseNoneNoneFalseNoneFalse24659.43480
3573805129911NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.153.98FalseNoneNoneFalseNoneFalse28596.8970
3573806129911NoneVOL I for the year 2023-24. Sl. No. 16 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3592.573592.573.98FalseNoneNoneFalseNoneFalse14298.42860
3573807129911NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1518.88FalseNoneNoneFalseNoneFalse135655.6320
3573808129911NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.0918.88FalseNoneNoneFalseNoneFalse81393.37920
3573809129911NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1571.16FalseNoneNoneFalseNoneFalse511295.2740
3573810129911NoneVOL I for the year 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3592.583592.5871.16FalseNoneNoneFalseNoneFalse255647.99280
3573811129911NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.152.2FalseNoneNoneFalseNoneFalse15807.330
3573812129911NoneVOL I for the year 2023-24. Sl. No. 19 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3233.323233.322.2FalseNoneNoneFalseNoneFalse7113.3040
3573813129911NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.576.05FalseNoneNoneFalseNoneFalse104606.7750
3573814129911NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.5413.23FalseNoneNoneFalseNoneFalse568397.8650
3573815129911NoneVOL II for the year 2023-24. I. No. 6.34 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1159.21159.242.05FalseNoneNoneFalseNoneFalse48744.360
3573816129911NoneVOL II for the year 2023-24. I. No. 6.16 P.No. 15)Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.16 P.No. 15)Sqm99.7599.7542.05FalseNoneNoneFalseNoneFalse4194.48750
3573817129911NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm253.05253.05740.33FalseNoneNoneFalseNoneFalse187340.50650
3573818129911NoneVOL II for the year 2023-24. I. No. 8.2.2 P.No. 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.95788.79FalseNoneNoneFalseNoneFalse231076.03050
3573819129911NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.95199.59FalseNoneNoneFalseNoneFalse58469.89050
3573820129911NoneVOL II for the year 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm105.0105.01168.68FalseNoneNoneFalseNoneFalse122711.40
3573821129911NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum103755.75103755.750.81FalseNoneNoneFalseNoneFalse84042.15750
3573822129911NoneVOL II 2023-24. I. No. 12.54 P.No. 104)Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.54 P.No. 104)Sqm333.9333.922.8FalseNoneNoneFalseNoneFalse7612.920
3573823129911NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3488.13488.122.47FalseNoneNoneFalseNoneFalse78377.6070
3573824129911NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7070.77070.741.04FalseNoneNoneFalseNoneFalse290181.5280
3573825129911NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1104.61104.620.0FalseNoneNoneFalseNoneFalse22092.00
3573826129911NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos107.1107.154.0FalseNoneNoneFalseNoneFalse5783.40
3573827129911NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos126.0126.010.0FalseNoneNoneFalseNoneFalse1260.00
3573828129911NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos248.85248.8520.0FalseNoneNoneFalseNoneFalse4977.00
3573829129911NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos136.5136.520.0FalseNoneNoneFalseNoneFalse2730.00
3573830129911NoneVOL I 2023-24. I. No. 12.55.1 P.No. 104)Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. with both side prelam (PWD CSR VOL I for the year 2023-24. I. No. 12.55.1 P.No. 104)Sqm2484.32484.36.3FalseNoneNoneFalseNoneFalse15651.090
3573831129911NoneVOL II 2023-24. I. No. 12.85 P.No. 109)Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.85 P.No. 109)Sqm6004.956004.952.52FalseNoneNoneFalseNoneFalse15132.4740
3573832129911NoneVOL 2 for the year 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1066.81066.810.0FalseNoneNoneFalseNoneFalse10668.00
3573833129911NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg192.15192.15922.32FalseNoneNoneFalseNoneFalse177223.7880
3573834129911NoneVOL II for the year 2023-24. I. No. 11.3 P.No. 77)Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.3 P.No. 77)Sqm8689.88689.88.37FalseNoneNoneFalseNoneFalse72733.6260
3573835129911NoneVOL II 2023-24. I. No. 11.6.1 P.No. 78)Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.6.1 P.No. 78)Sqm2764.652764.658.37FalseNoneNoneFalseNoneFalse23140.12050
3573836129911NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1233.751233.75310.02FalseNoneNoneFalseNoneFalse382487.1750
3573837129911NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.1120.87FalseNoneNoneFalseNoneFalse327690.6570
3573838129911NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.148.84FalseNoneNoneFalseNoneFalse132410.1240
3573839129911NoneVOL II for the year 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m344.4344.487.48FalseNoneNoneFalseNoneFalse30128.1120
3573840129911NoneVOL II for the year 2023-24. I. No. 9.11 P.No. 60)Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.11 P.No. 60)Sqm933.45933.4525.25FalseNoneNoneFalseNoneFalse23569.61250
3573841129911NoneVOL II for the year 2023-24. I. No. 9.39 P.No. 65)Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.39 P.No. 65)Sqm1521.451521.4553.08FalseNoneNoneFalseNoneFalse80758.5660
3573842129911NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm144.9144.957.45FalseNoneNoneFalseNoneFalse8324.5050
3573843129911NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm145.95145.9599.09FalseNoneNoneFalseNoneFalse14462.18550
3573844129911NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9740.33FalseNoneNoneFalseNoneFalse122820.7470
3573845129911NoneVOL II 2023-24. I. No. 11.26.1 P.No. 84)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.26.1 P.No. 84)Kg144.9144.9496.18FalseNoneNoneFalseNoneFalse71896.4820
3573846129911NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9428.35FalseNoneNoneFalseNoneFalse71063.2650
3573847129911NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm182.7182.7788.79FalseNoneNoneFalseNoneFalse144111.9330
3573848129911NoneVOL II for the year 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
3573849129911NoneVOL II for the year 2023-24. I. No. 8.49 P.No. 49)Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.49 P.No. 49)cm4.24.23300.0FalseNoneNoneFalseNoneFalse13860.00
3573850129911NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne93929.8593929.8520.34FalseNoneNoneFalseNoneFalse1910533.1490
3573851129911NoneV-2 8.16.2 PG.NO 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m39.939.9636.51FalseNoneNoneFalseNoneFalse25396.7490
17216278580001NoneNoneBuildingsGARALDINNI SCHOOL BUILDING FIRST FLOOR5506233.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3573852129912NoneVOL I 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6593.136593.132.19FalseNoneNoneFalseNoneFalse14438.95470
3573853129912NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3955.883955.882.19FalseNoneNoneFalseNoneFalse8663.37720
3573854129912NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.05.68FalseNoneNoneFalseNoneFalse41219.760
3573855129912NoneVOL 1 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.25.68FalseNoneNoneFalseNoneFalse24731.8560
3573856129912NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7257.07257.03.98FalseNoneNoneFalseNoneFalse28882.860
3573857129912NoneVOL I for the year 2023-24. Sl. No. 16 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3628.53628.53.98FalseNoneNoneFalseNoneFalse14441.430
3573858129912NoneVOL I 023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7257.07257.013.19FalseNoneNoneFalseNoneFalse95719.830
3573859129912NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5079.95079.913.19FalseNoneNoneFalseNoneFalse67003.8810
3573860129912NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.018.82FalseNoneNoneFalseNoneFalse136576.740
3573861129912NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.218.82FalseNoneNoneFalseNoneFalse81946.0440
3573862129912NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.067.27FalseNoneNoneFalseNoneFalse488178.390
3573863129912NoneVOL I for the year 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3628.53628.567.27FalseNoneNoneFalseNoneFalse244089.1950
3573864129912NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.01.96FalseNoneNoneFalseNoneFalse14223.720
3573865129912NoneVOL I for the year 2023-24. Sl. No. 19 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3265.653265.651.96FalseNoneNoneFalseNoneFalse6400.6740
3573866129912NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1389.251389.25458.63FalseNoneNoneFalseNoneFalse637151.72750
3573867129912NoneVOL II 2023-24. I. No. 6.34 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1170.791170.7930.07FalseNoneNoneFalseNoneFalse35205.65530
3573868129912NoneVOL II 2023-24. I. No. 6.16 P.No. 15)Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.16 P.No. 15)Sqm100.75100.7530.07FalseNoneNoneFalseNoneFalse3029.55250
3573869129912NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm255.58255.58770.77FalseNoneNoneFalseNoneFalse196993.39660
3573870129912NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm295.88295.88628.66FalseNoneNoneFalseNoneFalse186007.92080
3573871129912NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm295.88295.8839.85FalseNoneNoneFalseNoneFalse11790.8180
3573872129912NoneVOL II 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm106.05106.051253.23FalseNoneNoneFalseNoneFalse132905.04150
3573873129912NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum104793.31104793.310.91FalseNoneNoneFalseNoneFalse95361.91210
3573874129912NoneVOL II 2023-24. I. No. 12.54 P.No. 104)Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.54 P.No. 104)Sqm337.24337.2417.1FalseNoneNoneFalseNoneFalse5766.8040
3573875129912NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3522.983522.9826.1FalseNoneNoneFalseNoneFalse91949.7780
3573876129912NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7141.417141.4139.6FalseNoneNoneFalseNoneFalse282799.8360
3573877129912NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1115.651115.6522.0FalseNoneNoneFalseNoneFalse24544.30
3573878129912NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos108.17108.1766.0FalseNoneNoneFalseNoneFalse7139.220
3573879129912NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos127.26127.2611.0FalseNoneNoneFalseNoneFalse1399.860
3573880129912NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos251.34251.3422.0FalseNoneNoneFalseNoneFalse5529.480
3573881129912NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos137.86137.8685.0FalseNoneNoneFalseNoneFalse11718.10
3573882129912NoneVOL I2023-24. I. No. 12.55.1 P.No. 104)Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. with both side prelam (PWD CSR VOL I for the year 2023-24. I. No. 12.55.1 P.No. 104)Sqm2509.142509.144.72FalseNoneNoneFalseNoneFalse11843.14080
3573883129912NoneVOL II 2023-24. I. No. 12.85 P.No. 109)Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.85 P.No. 109)Sqm6065.06065.02.52FalseNoneNoneFalseNoneFalse15283.80
3573884129912NoneVOL 2 for the year 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1077.471077.4711.0FalseNoneNoneFalseNoneFalse11852.170
3573885129912NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg194.07194.07914.76FalseNoneNoneFalseNoneFalse177527.47320
3573886129912NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1246.081246.08285.45FalseNoneNoneFalseNoneFalse355693.5360
3573887129912NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2738.212738.21124.53FalseNoneNoneFalseNoneFalse340989.29130
3573888129912NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2738.212738.2125.53FalseNoneNoneFalseNoneFalse69906.50130
3573889129912NoneVOL II for the year 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m347.84347.8439.6FalseNoneNoneFalseNoneFalse13774.4640
3573890129912NoneVOL II for the year 2023-24. I. No. 9.11 P.No. 60)Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.11 P.No. 60)Sqm942.78942.7822.69FalseNoneNoneFalseNoneFalse21391.67820
3573891129912NoneVOL II for the year 2023-24. I. No. 9.39 P.No. 65)Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.39 P.No. 65)Sqm1536.661536.6639.85FalseNoneNoneFalseNoneFalse61235.9010
3573892129912NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm146.35146.35165.02FalseNoneNoneFalseNoneFalse24150.6770
3573893129912NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm147.41147.4173.17FalseNoneNoneFalseNoneFalse10785.98970
3573894129912NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.56770.77FalseNoneNoneFalseNoneFalse129150.22120
3573895129912NoneVOL II 2023-24. I. No. 11.26.1 P.No. 84)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.26.1 P.No. 84)Kg146.35146.35622.0FalseNoneNoneFalseNoneFalse91029.70
3573896129912NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.56433.26FalseNoneNoneFalseNoneFalse72597.04560
3573897129912NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm184.53184.53628.66FalseNoneNoneFalseNoneFalse116006.62980
3573898129912NoneVOL II for the year 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm503.74503.7418.0FalseNoneNoneFalseNoneFalse9067.320
3573899129912NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne94869.1594869.1510.04FalseNoneNoneFalseNoneFalse952486.2660
3573900129912NoneV-2 I.NO 8.16.2 PG. 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m40.340.3636.51FalseNoneNoneFalseNoneFalse25651.3530
17216278590001NoneNoneBuildingsGARALDINNI SCHOOL BUILDING SECOND FLOOR5304077.17
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3573901129913NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6658.416658.412.2FalseNoneNoneFalseNoneFalse14648.5020
3573902129913NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3995.043995.042.2FalseNoneNoneFalseNoneFalse8789.0880
3573903129913NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.855.51FalseNoneNoneFalseNoneFalse40381.96350
3573904129913NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4397.314397.315.51FalseNoneNoneFalseNoneFalse24229.17810
3573905129913NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7328.857328.853.98FalseNoneNoneFalseNoneFalse29168.8230
3573906129913NoneVOL I for the year 2023-24. Sl. No. 16 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3664.433664.433.98FalseNoneNoneFalseNoneFalse14584.43140
3573907129913NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7328.857328.8513.19FalseNoneNoneFalseNoneFalse96667.53150
3573908129913NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5130.195130.1913.19FalseNoneNoneFalseNoneFalse67667.20610
3573909129913NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.8518.82FalseNoneNoneFalseNoneFalse137928.9570
3573910129913NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4397.314397.3118.82FalseNoneNoneFalseNoneFalse82757.37420
3573911129913NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.8567.27FalseNoneNoneFalseNoneFalse493011.73950
3573912129913NoneVOL I for the year 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3664.423664.4267.27FalseNoneNoneFalseNoneFalse246505.53340
3573913129913NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.851.76FalseNoneNoneFalseNoneFalse12898.7760
3573914129913NoneVOL I for the year 2023-24. Sl. No. 19 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3297.983297.981.76FalseNoneNoneFalseNoneFalse5804.44480
3573915129913NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1403.011403.01408.25FalseNoneNoneFalseNoneFalse572778.83250
3573916129913NoneVOL II for the year 2023-24. I. No. 6.34 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1182.381182.3857.55FalseNoneNoneFalseNoneFalse68045.9690
3573917129913NoneVOL II for the year 2023-24. I. No. 6.16 P.No. 15)Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.16 P.No. 15)Sqm101.74101.7457.55FalseNoneNoneFalseNoneFalse5855.1370
3573918129913NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm258.11258.11610.42FalseNoneNoneFalseNoneFalse157555.50620
3573919129913NoneVOL II for the year 2023-24. I. No. 8.2.2 P.No. 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm298.81298.81591.54FalseNoneNoneFalseNoneFalse176758.06740
3573920129913NoneVOL II for the year 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm107.1107.11017.08FalseNoneNoneFalseNoneFalse108929.2680
3573921129913NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum105830.86105830.860.82FalseNoneNoneFalseNoneFalse86781.30520
3573922129913NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3557.863557.8623.73FalseNoneNoneFalseNoneFalse84428.01780
3573923129913NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7212.117212.1143.2FalseNoneNoneFalseNoneFalse311563.1520
3573924129913NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1126.691126.6920.0FalseNoneNoneFalseNoneFalse22533.80
3573925129913NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos109.24109.2466.0FalseNoneNoneFalseNoneFalse7209.840
3573926129913NoneVOL II f 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos128.52128.5211.0FalseNoneNoneFalseNoneFalse1413.720
3573927129913NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos253.83253.8322.0FalseNoneNoneFalseNoneFalse5584.260
3573928129913NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos139.23139.2322.0FalseNoneNoneFalseNoneFalse3063.060
3573929129913NoneVOL 2 for the year 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.51 P.No. 104)Nos1088.141088.1410.0FalseNoneNoneFalseNoneFalse10881.40
3573930129913NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg195.99195.99907.2FalseNoneNoneFalseNoneFalse177802.1280
3573931129913NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1258.421258.42308.8FalseNoneNoneFalseNoneFalse388600.0960
3573932129913NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2765.322765.32124.59FalseNoneNoneFalseNoneFalse344531.21880
3573933129913NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2765.322765.3225.54FalseNoneNoneFalseNoneFalse70626.27280
3573934129913NoneVOL II 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m351.28351.2839.6FalseNoneNoneFalseNoneFalse13910.6880
3573935129913NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm147.79147.79164.16FalseNoneNoneFalseNoneFalse24261.20640
3573936129913NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm148.87148.8772.81FalseNoneNoneFalseNoneFalse10839.22470
3573937129913NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm169.22169.22610.42FalseNoneNoneFalseNoneFalse103295.27240
3573938129913NoneVOL II 2023-24. I. No. 11.26.1 P.No. 84)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.26.1 P.No. 84)Kg147.8147.8622.0FalseNoneNoneFalseNoneFalse91931.60
3573939129913NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm169.22169.22406.66FalseNoneNoneFalseNoneFalse68815.00520
3573940129913NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm186.34186.34591.54FalseNoneNoneFalseNoneFalse110227.56360
3573941129913NoneVOL II 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm508.72508.7218.0FalseNoneNoneFalseNoneFalse9156.960
3573942129913NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne95808.4495808.4410.08FalseNoneNoneFalseNoneFalse965749.07520
3573943129913NoneV-2 I.NO 8.16.2 PG.NO 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m40.740.7636.51FalseNoneNoneFalseNoneFalse25905.9570
17216278590001NoneNoneBuildingsGaraldinni School Building Terrace Floor600981.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3573944129914NoneVOL I I. No. 2.5.2 P.No. 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7400.77400.71.32FalseNoneNoneFalseNoneFalse9768.9240
3573945129914NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5180.495180.491.32FalseNoneNoneFalseNoneFalse6838.24680
3573946129914NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6723.686723.683.43FalseNoneNoneFalseNoneFalse23062.22240
3573947129914NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum4706.584706.583.43FalseNoneNoneFalseNoneFalse16143.56940
3573948129914NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1416.761416.7642.73FalseNoneNoneFalseNoneFalse60538.15480
3573949129914NoneVOL II for the year 2023-24. I. No. 6.34 P.No. 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1193.971193.97103.58FalseNoneNoneFalseNoneFalse123671.41260
3573950129914NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6723.686723.680.88FalseNoneNoneFalseNoneFalse5916.83840
3573951129914NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4034.214034.210.88FalseNoneNoneFalseNoneFalse3550.10480
3573952129914NoneVOL II for the year 2023-24. I. No. 8.1.2 P.No. 41Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm260.64260.6446.99FalseNoneNoneFalseNoneFalse12247.47360
3573953129914NoneVOL II for the year 2023-24. I. No. 8.2.2 P.No. 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm301.74301.74475.61FalseNoneNoneFalseNoneFalse143510.56140
3573954129914NoneVOL II 2023-24. I. No. 8.51 P.No. 50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm108.15108.1546.99FalseNoneNoneFalseNoneFalse5081.96850
3573955129914NoneVOL II 2023-24. I. No. 11.5.2 P.No. 77Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.5.2 P.No. 77)Sqm4587.724587.721.74FalseNoneNoneFalseNoneFalse7982.63280
3573956129914NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm170.87170.8746.99FalseNoneNoneFalseNoneFalse8029.18130
3573957129914NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm188.18188.18475.61FalseNoneNoneFalseNoneFalse89500.28980
3573958129914NoneVOL II for the year 2023-24. I. No. 7.19 P.No. 23Providing and laying to required line and slope roofing with semicorrugated ( Trafford ) asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers, over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 7.19 P.No. 23)Sqm404.48404.4832.08FalseNoneNoneFalseNoneFalse12975.71840
3573959129914NoneVOL 2 2023-24. I. No. 11.25.2 P.No. 84Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.25.2 P.No. 84)Kg147.08147.08351.04FalseNoneNoneFalseNoneFalse51630.96320
3573960129914NoneVOL I for the year 2023-24. I. No. 2.11.a P.No. 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)t96747.7496747.740.2FalseNoneNoneFalseNoneFalse19349.5480
3573961129914NoneV-2 I.NO 8.16.2 PG.NO 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m41.141.128.8FalseNoneNoneFalseNoneFalse1183.680
17216278590001NoneNoneBuildingsGaraldinni School Building Water Supply & Sanitary758529.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3573962129915NoneV-5 WS & SB 2023-24. Sl No. 21.1.1 P.No.247Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componentsEach26250.026250.01.0FalseNoneNoneFalseNoneFalse26250.00
3573963129915NoneVOL II 2023-24. I. No. 13.34 Page No 123 )Providing and placing on terrace (at all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tankl9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3573964129915NoneVOL II 2023-24. I. No. 13.33.5 Page No 123)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 40MM Dia Pipe over terrace distribution from TankMtr500.85500.8585.0FalseNoneNoneFalseNoneFalse42572.250
3573965129915NoneVOL II 2023-24. I. No. 13.33.4 Page No 122)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 32MM DiaMtr390.6390.685.0FalseNoneNoneFalseNoneFalse33201.00
3573966129915NoneVOL II 2023-24. I. No. 13.32.3 Page No 122)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 25MM Dia PipeMtr500.85500.8585.0FalseNoneNoneFalseNoneFalse42572.250
3573967129915NoneVOL II 2023-24. I. No. 13.32.2 Page No 122)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 20MM Dia PipeMtr397.95397.9585.0FalseNoneNoneFalseNoneFalse33825.750
3573968129915NoneVOL II 2023-24. I. No. 13.2.1 Page No 117)Providing and fixing brass bib cock of approved quality : 15 mm nominal boreEach300.3300.330.0FalseNoneNoneFalseNoneFalse9009.00
3573969129915NoneVOL II 2023-24. I. No. 13.3.2 Page No 117Providing and fixing brass stop cock of approved quality : 20 mm nominal boreEach320.25320.2510.0FalseNoneNoneFalseNoneFalse3202.50
3573970129915NoneVOL II 2023-24. I. No. 14.7.2 Page No 132)Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tapUnit2689.052689.0510.0FalseNoneNoneFalseNoneFalse26890.50
3573971129915NoneVOL II 2023-24. I. No. 13.8.2.2 Page No. 118)Providing and fixing unplasticised PVC connection pipe with brass unions : 20 mm nominal boreSet115.5115.510.0FalseNoneNoneFalseNoneFalse1155.00
3573972129915NoneVOL II 2023-24. I. No. 14.24 Page No. 117)Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.Each2976.752976.753.0FalseNoneNoneFalseNoneFalse8930.250
3573973129915NoneVOL II 2023-24. I. No. 14.29 Page No. 136)Providing and fixing 100 mm sand cast Iron grating for gully trap.Each49.3549.353.0FalseNoneNoneFalseNoneFalse148.050
3573974129915NoneVOL II 2023-24. I. No. 10.8 Page No. 70)Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm2928.452928.4528.08FalseNoneNoneFalseNoneFalse82230.8760
3573975129915NoneVOL II 2023-24.I. No. 14.5.1 Page No. 132)Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach9074.19074.13.0FalseNoneNoneFalseNoneFalse27222.30
3573976129915NoneVOL II I. No. 14.1.1 Page No. 131)Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.27.0FalseNoneNoneFalseNoneFalse35897.40
3573977129915NoneVOL II 2023-24. I. No. 13.59 Page No. 127)Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach231.0231.025.0FalseNoneNoneFalseNoneFalse5775.00
3573978129915NoneVOL I 2023-24.I. No. 1.15.1 Page No. 08)Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum381.15381.1546.8FalseNoneNoneFalseNoneFalse17837.820
3573979129915NoneVOL II 2023-24.I. No. 13.53 Page No. 126)Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Each5924.15924.112.0FalseNoneNoneFalseNoneFalse71089.20
3573980129915NoneVOL II 2023-24. I. No. 13.64.3 P.No. 128 )Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipesMtr806.4806.440.0FalseNoneNoneFalseNoneFalse32256.00
3573981129915NoneVOL II 2023-24.I. No. 13.64.2 Page No. 128)Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesMtr404.25404.25120.0FalseNoneNoneFalseNoneFalse48510.00
3573982129915NoneVOL II 2023-24.I. No. 13.48 Page No. 125)Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterm305.55305.5596.0FalseNoneNoneFalseNoneFalse29332.80
3573983129915NoneVOL I 2023-24.I. No. 2.1.3 Page No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.452.0FalseNoneNoneFalseNoneFalse12576.90
3573984129915NoneVOL II 2023-24.I. No. 6.32 Page No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.538.79FalseNoneNoneFalseNoneFalse53355.6450
3573985129915NoneV-II 2023-24 I. No. 6.34 P.No. 07Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.25.4FalseNoneNoneFalseNoneFalse6259.680
3573986129915NoneVOL I 2023-24 I. No. 2.5.2 P.No. 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.151.52FalseNoneNoneFalseNoneFalse10921.4280
3573987129915NoneVOL I for the year 2023-24 I. No. 15 P.No.112Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50%Cum3592.583592.5815.15FalseNoneNoneFalseNoneFalse54427.5870
3573988129915NoneV-II for the year 2023-24, I. No. 8.3.2 P.No. 41Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm349.65349.6536.4FalseNoneNoneFalseNoneFalse12727.260
3573989129915NoneV-5 for the year 2023-24. Sl. No. 18.3 P.No. 221)Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each2060.12060.11.0FalseNoneNoneFalseNoneFalse2060.10
3573990129915NoneV - I for the year 2023-24, I. No. 2.11.a P.No.18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
17216278590001NoneNoneBuildingsGaraldinni School Building Water Sump231050.33
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3573991129916NoneVOL I 2023-24. I. No. 1.14.1 P.No. 08 )Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR VOL I for the year 2023-24. I. No. 1.14.1 P.No. 08 )Cum107.1107.1100.0FalseNoneNoneFalseNoneFalse10710.00
3573992129916NoneVOL I 2023-24. I. No. 2.1.3 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15)Cum6288.456288.453.75FalseNoneNoneFalseNoneFalse23581.68750
3573993129916NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.83.22FalseNoneNoneFalseNoneFalse21422.0160
3573994129916NoneVOL I 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3326.43326.43.22FalseNoneNoneFalseNoneFalse10711.0080
3573995129916NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.85.4FalseNoneNoneFalseNoneFalse35925.120
3573996129916NoneVOL I 2023-24. Sl. No. 11 P.No. 112)Appendix I Additionalities for Formwork, Centering & Scaffolding for Earth retaining structures 10% (PWD CSR VOL I for the year 2023-24. Sl. No. 11 P.No. 112)Cum665.28665.285.4FalseNoneNoneFalseNoneFalse3592.5120
3573997129916NoneVOL II 2023-24. I. No. 8.8 P.No. 42)Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.8 P.No. 42)Sqm389.55389.5554.0FalseNoneNoneFalseNoneFalse21035.70
3573998129916NoneVOL II 2023-24. I. No. 15.6 P.No. 150)Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification (PWD SR for Buildings VOL II for the year 2023-24. I. No. 15.6 P.No. 150)Sqm532.35532.3554.0FalseNoneNoneFalseNoneFalse28746.90
3573999129916NoneV-5 CSR 2023-24. Sl No. 18.3 P.No.150)Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.. (WS & Sewerage Works CSR for the year 2023-24. Sl No. 18.3 P.No.150)Cum2060.12060.11.0FalseNoneNoneFalseNoneFalse2060.10
3574000129916NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)t93929.8593929.850.78FalseNoneNoneFalseNoneFalse73265.2830
17216278590001NoneNoneBuildingsGARALDINNI SCHOOL BUILDING ELECTRIFICATION WORK671825.2
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3574001129917NoneELE SR 23-24V-6 P-III It No 1.2.1 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr69.369.3850.0FalseNoneNoneFalseNoneFalse58905.00
3574002129917NoneELE SR 23-24V-6 P-III It No 1.2.2 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr81.981.9200.0FalseNoneNoneFalseNoneFalse16380.00
3574003129917NoneELE SR 23-24V-6 P-III It No 1.3.1 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr71.471.4280.0FalseNoneNoneFalseNoneFalse19992.00
3574004129917NoneELE SR 23-24V-6 P-III It No 1.3.2 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr82.9582.9575.0FalseNoneNoneFalseNoneFalse6221.250
3574005129917NoneELE SR 23-24V-6 P-III It No 1.13 Pg.No 04 of 105Supplying And Fixing Metal Fan Box with Round Hook.Each122.85122.8541.0FalseNoneNoneFalseNoneFalse5036.850
3574006129917NoneELE SR 23-24V-6 P-III It No 2.2.1 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch boxPoint282.45282.4542.0FalseNoneNoneFalseNoneFalse11862.90
3574007129917NoneELE SR 23-24V-6 P-III It No 2.2.2 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.9558.0FalseNoneNoneFalseNoneFalse23081.10
3574008129917NoneELE SR 23-24V-6 P-III It No 2.2.3 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.7512.0FalseNoneNoneFalseNoneFalse6993.00
3574009129917NoneELE SR 23-24V-6 P-III It No 2.3.2 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 1.5sqmm.Mtr27.327.31850.0FalseNoneNoneFalseNoneFalse50505.00
3574010129917NoneELE SR 23-24V-6 P-III It No 2.3.3 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 2.5sqmm.Mtr44.144.11850.0FalseNoneNoneFalseNoneFalse81585.00
3574011129917NoneELE SR 23-24V-6 P-III It No 2.3.4 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 4.0sqmm.Mtr66.1566.15200.0FalseNoneNoneFalseNoneFalse13230.00
3574012129917NoneELE SR 23-24V-6 P-III It No 3.1.1 Pg.No 08 of 105Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 WayEach134.4134.44.0FalseNoneNoneFalseNoneFalse537.60
3574013129917NoneELE SR 23-24V-6 P-III It No 3.3.3 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 WayEach143.85143.8522.0FalseNoneNoneFalseNoneFalse3164.70
3574014129917NoneELE SR 23-24V-6 P-III It No 3.3.5 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 - WayEach229.95229.9520.0FalseNoneNoneFalseNoneFalse4599.00
3574015129917NoneELE SR 23-24V-6 P-III It No 3.3.6 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 WayEach274.05274.0514.0FalseNoneNoneFalseNoneFalse3836.70
3574016129917NoneELE SR 23-24V-6 P-III It No 3.5.3 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4-5 ModuleEach183.75183.7522.0FalseNoneNoneFalseNoneFalse4042.50
3574017129917NoneELE SR 23-24V-6 P-III It No 3.5.5 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 - ModuleEach298.2298.220.0FalseNoneNoneFalseNoneFalse5964.00
3574018129917NoneELE SR 23-24V-6 P-III It No 3.5.6 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach361.2361.214.0FalseNoneNoneFalseNoneFalse5056.80
3574019129917NoneELE SR 23-24V-6 P-III It No 3.6.1 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps One way switch.Each107.1107.184.0FalseNoneNoneFalseNoneFalse8996.40
3574020129917NoneELE SR 23-24V-6 P-III It No 3.6.4 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - Stepped Fan Regulator Two ModuleEach374.85374.8541.0FalseNoneNoneFalseNoneFalse15368.850
3574021129917NoneELE SR 23-24V-6 P-III It No 3.6.7Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 16 A One Way SwitchEach189.0189.010.0FalseNoneNoneFalseNoneFalse1890.00
3574022129917NoneELE SR 23-24V-6 P-III It No 3.6.10Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6/16 A Universal SocketEach247.8247.830.0FalseNoneNoneFalseNoneFalse7434.00
3574023129917NoneELE SR 23-24V-6 P-III It No 3.6.11Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - TV / Telephone SocketEach163.8163.82.0FalseNoneNoneFalseNoneFalse327.60
3574024129917NoneELE SR 23-24V-6 P-III It No 3.6.12Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - RJ 45/I.O Outlet Cat-6Each353.85353.8510.0FalseNoneNoneFalseNoneFalse3538.50
3574025129917NoneELE SR 23-24V-6 P-III It No 5.8.1 Pg.No 15 of 105Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. - 63AmpsEach2427.62427.61.0FalseNoneNoneFalseNoneFalse2427.60
3574026129917NoneELE SR 23-24V-6 P-III It No 5.17.3 Pg.No 17 of 105Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. - 12-WayEach16305.4516305.452.0FalseNoneNoneFalseNoneFalse32610.90
3574027129917NoneELE SR 23-24V-6 P-III It No 5.18.1 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SPEach435.75435.752.0FalseNoneNoneFalseNoneFalse871.50
3574028129917NoneELE SR 23-24V-6 P-III It No 5.18.4 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DPEach775.95775.952.0FalseNoneNoneFalseNoneFalse1551.90
3574029129917NoneELE SR 23-24V-6 P-III It No 5.19.4 Pg.No 18 of 105Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door -12 Way SP &NEach1956.151956.152.0FalseNoneNoneFalseNoneFalse3912.30
3574030129917NoneELE SR 23-24V-6 P-III It No 5.20.4 Pg.No 13 of 105Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. - 63 Amps 4 poleEach3210.93210.91.0FalseNoneNoneFalseNoneFalse3210.90
3574031129917NoneELE SR 23-24V-6 P-III It No 5.42.1Pg.No 20 of 105Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. - 14SWGSq CM0.520.529500.0FalseNoneNoneFalseNoneFalse4940.00
3574032129917NoneELE SR 23-24V-6 P-III It No 5.44.1Pg.No 21 of 105Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. - 300mmx300mmx214mmEach4737.64737.61.0FalseNoneNoneFalseNoneFalse4737.60
3574033129917NoneELE SR 23-24V-6 P-III It No 6.3.1 Pg.No 30 of 105Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.Each3133.23133.241.0FalseNoneNoneFalseNoneFalse128461.20
3574034129917NoneELE SR 23-24V-6 P-III It No 6.2.1 Pg.No 30 of 105Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each3117.453117.454.0FalseNoneNoneFalseNoneFalse12469.80
3574035129917NoneELE SR 23-24V-6 P-III It No 8.2.2 Pg.No 36 of 105Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2PairMtr22.0522.05200.0FalseNoneNoneFalseNoneFalse4410.00
3574036129917NoneELE SR 23-24V-6 P-III It No 8.10.2 Pg.No 37 of 105Supplying & fixing of I/O socket with back box - Double I/oEach577.5577.510.0FalseNoneNoneFalseNoneFalse5775.00
3574037129917NoneELE 23-24V-6 P-III It No 8.11.2 Pg.No 37 of 105Supplying & Fixing of …mtrs Cat6 Patch Cable - 2mtrEach269.85269.8510.0FalseNoneNoneFalseNoneFalse2698.50
3574038129917NoneELE SR 23-24V-6 P-III It No 8.12.3 Pg.No 37 of 105Supplying & Fixing of Patch panel for LAN cabling - 16 Port 10/100 patch panelEach3202.53202.51.0FalseNoneNoneFalseNoneFalse3202.50
3574039129917NoneELE SR 23-24V-6 P-III It No 8.13.1 Pg.No 37 of 105Supplying and fixing of MDF krone junction box with KRONE Module / Telephone - cable termination. - 10 Pairm362.25362.255.0FalseNoneNoneFalseNoneFalse1811.250
3574040129917NoneELE SR 23-24V-6 P-III It No 11.3.2 Pg.No 43 of 105Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4'- 20/22 wEach724.5724.560.0FalseNoneNoneFalseNoneFalse43470.00
3574041129917NoneELE SR 23-24V-6 P-III It No 11.8.2 Pg.No 46 of 105Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 40wattsEach4225.24225.21.0FalseNoneNoneFalseNoneFalse4225.20
3574042129917NoneELE SR 23-24V-6 P-III It No 13.7.1 Pg.No 56 of 105Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / GirdersEach128.1128.146.0FalseNoneNoneFalseNoneFalse5892.60
3574043129917NoneELE SR 23-24V-6 P-III It No 13.5 Pg.No 56 of 105Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each170.1170.11.0FalseNoneNoneFalseNoneFalse170.10
3574044129917NoneELE SR 23-24V-6 P-III It No 13.10 Pg.No 56 of 105Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.5541.0FalseNoneNoneFalseNoneFalse7361.550
3574045129917NoneELE SR 23-24V-6 P-III It No 13.14 Pg.No 57 of 105Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each516.6516.64.0FalseNoneNoneFalseNoneFalse2066.40
3574046129917NoneUNI SR 23-24 Escoms V-6 P-II It No 32.04 P 13Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 16 sqmmKm92838.992838.90.08FalseNoneNoneFalseNoneFalse7427.1120
3574047129917NoneUNISR 2023-24 Esc V-6 P-II Sl.197 I.no 32.01 Pg 13Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 6 sqmmKm66576.366576.30.02FalseNoneNoneFalseNoneFalse1331.5260
3574048129917NoneUNISR 23-24 Esc V-6 P-II Sno. 167 I.no 20.05 Pg 52Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 2.5 sqmm to 25 sqmmKm1246.351246.350.1FalseNoneNoneFalseNoneFalse124.6350
3574049129917NoneUNISR 2021-22 Bsc V-6 P-II Sno. 201 I.no 29.02-08Earth work Excavation for cable trench of 0.5m to 0.75 mtr width and Depth upto 1 Mtrs including trial pits, depositing on bank upto a lead of 50 Mtrs , Supplying and Displaying necessary Danger Boards and Lighting , Using sight Rails and Sign Boards at every 100 Mtrs wherever necessary as directed. In soil (Ordinary) (1x70x0.50x0.75 = 26.25 CMT)Cum273.0273.026.25FalseNoneNoneFalseNoneFalse7166.250
3574050129917NoneUNISR 21-22 BSC V-6 P-II Sno.206 I.NO 29.07 Pg 08Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. (1x70x0.50x0.75 = 26.25 CMT)Cum60.960.926.25FalseNoneNoneFalseNoneFalse1598.6250
3574051129917NoneELE SR 23-24V-6 P-III It No 5.31 Pg.No 19 of 105Supplying and fixing Trivector Meter suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.Each4609.54609.51.0FalseNoneNoneFalseNoneFalse4609.50
3574052129917NoneELE SR 23-24V-6 P-III It No 12.57 Pg.No 55 of 105Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each3685.53685.54.0FalseNoneNoneFalseNoneFalse14742.00
17216278590001NoneNoneBuildingsMAMDAPUR SCHOOL BUILDING GROUND FLOOR2347766.04
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3574053129918NoneVOL I 2023-24. I. No. 1.12 P.No. 08)Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (PWD CSR VOL I for the year 2023-24. I. No. 1.12 P.No. 08)Cum99.7599.7548.6FalseNoneNoneFalseNoneFalse4847.850
3574054129918NoneVOL I 2023-24. I. No. 1.14.1 P.No. 08 )Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR VOL I for the year 2023-24. I. No. 1.14.1 P.No. 08 )Cum107.1107.162.67FalseNoneNoneFalseNoneFalse6711.9570
3574055129918NoneVOL I 2023-24. I. No. 1.4.1 P.No. 05)Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD CSR VOL I for the year 2023-24. I. No. 1.4.1 P.No. 05)Cum254.1254.126.09FalseNoneNoneFalseNoneFalse6629.4690
3574056129918NoneVOL I 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6527.856527.852.13FalseNoneNoneFalseNoneFalse13904.32050
3574057129918NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3916.713916.712.13FalseNoneNoneFalseNoneFalse8342.59230
3574058129918NoneVOL I 2023-24. I. No. 2.1.3 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15)Cum6288.456288.4519.89FalseNoneNoneFalseNoneFalse125077.27050
3574059129918NoneVOL II 2023-24. I. No. 5.1.1 P.No. 9)Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 5.1.1 P.No. 9)Cum5891.555891.5512.74FalseNoneNoneFalseNoneFalse75058.3470
3574060129918NoneVOL II 2023-24. I. No. 5.2 & P.No. 9)Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ( PWD SR for Buildings VOL II for the year 2023-24. I. No. 5.2 & P.No. 9)Cum6948.96948.912.33FalseNoneNoneFalseNoneFalse85679.9370
3574061129918NoneVOL II 2023-24. I. No. 8.19.1 P.No. 44)Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.19.1 P.No. 44)Cum267.75267.7539.19FalseNoneNoneFalseNoneFalse10493.12250
3574062129918NoneVOL I 2023-24. I. No. 1.11 P.No. 07)Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. (PWD CSR VOL I for the year 2023-24. I. No. 1.11 P.No. 07)Cum454.65454.65144.19FalseNoneNoneFalseNoneFalse65555.98350
3574063129918NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.812.6FalseNoneNoneFalseNoneFalse83825.280
3574064129918NoneVOL I 2023-24. Sl. No. 1(b) P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for isolated footings 8%. (PWD CSR VOL I for the year 2023-24. Sl. No. 1(b) P.No. 111)Cum532.22532.2212.6FalseNoneNoneFalseNoneFalse6705.9720
3574065129918NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.81.43FalseNoneNoneFalseNoneFalse9513.5040
3574066129918NoneVOL I 2023-24. Sl. No. 9 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum4656.964656.961.43FalseNoneNoneFalseNoneFalse6659.45280
3574067129918NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.85.63FalseNoneNoneFalseNoneFalse37455.2640
3574068129918NoneVOL I 2023-24. Sl. No. 2 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings 50%. (PWD CSR VOL I for the year 2023-24. Sl. No. 2 P.No. 111)Cum3326.43326.45.63FalseNoneNoneFalseNoneFalse18727.6320
3574069129918NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.154.77FalseNoneNoneFalseNoneFalse34273.16550
3574070129918NoneVOL I 2023-24. Sl. No. 9 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5029.65029.64.77FalseNoneNoneFalseNoneFalse23991.1920
3574071129918NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.57185.51.57FalseNoneNoneFalseNoneFalse11281.2350
3574072129918NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.091.57FalseNoneNoneFalseNoneFalse6768.41130
3574073129918NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.153.1FalseNoneNoneFalseNoneFalse22273.9650
3574074129918NoneVOL I 2023-24. Sl. No. 16 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3592.573592.573.1FalseNoneNoneFalseNoneFalse11136.9670
3574075129918NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.154.93FalseNoneNoneFalseNoneFalse35422.78950
3574076129918NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.094.93FalseNoneNoneFalseNoneFalse21253.67370
3574077129918NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1518.57FalseNoneNoneFalseNoneFalse133428.23550
3574078129918NoneVOL I 2023-24. Sl. No. 15 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3592.583592.5818.57FalseNoneNoneFalseNoneFalse66714.21060
3574079129918NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.150.54FalseNoneNoneFalseNoneFalse3879.9810
3574080129918NoneVOL I 2023-24. Sl. No. 19 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3233.323233.320.54FalseNoneNoneFalseNoneFalse1745.99280
3574081129918NoneVOL II 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.523.79FalseNoneNoneFalseNoneFalse32723.1450
3574082129918NoneVOL II 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.5140.8FalseNoneNoneFalseNoneFalse193670.40
3574083129918NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm253.05253.05206.47FalseNoneNoneFalseNoneFalse52247.23350
3574084129918NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.95182.06FalseNoneNoneFalseNoneFalse53334.4770
3574085129918NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.9521.61FalseNoneNoneFalseNoneFalse6330.64950
3574086129918NoneVOL II 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm105.0105.0335.77FalseNoneNoneFalseNoneFalse35255.850
3574087129918NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum103755.75103755.750.16FalseNoneNoneFalseNoneFalse16600.920
3574088129918NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3488.13488.15.04FalseNoneNoneFalseNoneFalse17580.0240
3574089129918NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7070.77070.712.6FalseNoneNoneFalseNoneFalse89090.820
3574090129918NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1104.61104.64.0FalseNoneNoneFalseNoneFalse4418.40
3574091129918NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos107.1107.112.0FalseNoneNoneFalseNoneFalse1285.20
3574092129918NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos126.0126.02.0FalseNoneNoneFalseNoneFalse252.00
3574093129918NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos248.85248.854.0FalseNoneNoneFalseNoneFalse995.40
3574094129918NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos136.5136.54.0FalseNoneNoneFalseNoneFalse546.00
3574095129918NoneVOL 2 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1066.81066.82.0FalseNoneNoneFalseNoneFalse2133.60
3574096129918NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg192.15192.15264.6FalseNoneNoneFalseNoneFalse50842.890
3574097129918NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1233.751233.7575.04FalseNoneNoneFalseNoneFalse92580.60
3574098129918NoneVOL II 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.141.9FalseNoneNoneFalseNoneFalse113595.090
3574099129918NoneVOL II 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.127.13FalseNoneNoneFalseNoneFalse73552.1430
3574100129918NoneVOL II 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m344.4344.454.6FalseNoneNoneFalseNoneFalse18804.240
3574101129918NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm144.9144.912.1FalseNoneNoneFalseNoneFalse1753.290
3574102129918NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm145.95145.9520.06FalseNoneNoneFalseNoneFalse2927.7570
3574103129918NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9206.47FalseNoneNoneFalseNoneFalse34253.3730
3574104129918NoneVOL II 2023-24. I. No. 11.28 P.No. 85)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.28 P.No. 85)Kg144.9144.9156.76FalseNoneNoneFalseNoneFalse22714.5240
3574105129918NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9129.3FalseNoneNoneFalseNoneFalse21450.870
3574106129918NoneVOL II 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm182.7182.7182.06FalseNoneNoneFalseNoneFalse33262.3620
3574107129918NoneVOL II 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm498.75498.757.2FalseNoneNoneFalseNoneFalse3591.00
3574108129918NoneVOL II 2023-24. I. No. 8.49 P.No. 49)Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.49 P.No. 49)cm4.24.21000.0FalseNoneNoneFalseNoneFalse4200.00
3574109129918NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne93929.8593929.854.48FalseNoneNoneFalseNoneFalse420805.7280
3574110129918NoneV-2 I.no 8.16.2 Pg.no 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m39.939.9240.86FalseNoneNoneFalseNoneFalse9610.3140
17216278590001NoneNoneBuildingsMAMDAPUR SCHOOL BUILDING FIRST FLOOR1014061.67
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3574111129919NoneVOL I 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6593.136593.130.69FalseNoneNoneFalseNoneFalse4549.25970
3574112129919NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3955.883955.880.69FalseNoneNoneFalseNoneFalse2729.55720
3574113129919NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.01.11FalseNoneNoneFalseNoneFalse8055.270
3574114129919NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.21.11FalseNoneNoneFalseNoneFalse4833.1620
3574115129919NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7257.07257.02.7FalseNoneNoneFalseNoneFalse19593.90
3574116129919NoneVOL I 2023-24. Sl. No. 9 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5079.95079.92.7FalseNoneNoneFalseNoneFalse13715.730
3574117129919NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.03.17FalseNoneNoneFalseNoneFalse23004.690
3574118129919NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.23.17FalseNoneNoneFalseNoneFalse13802.8140
3574119129919NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.013.61FalseNoneNoneFalseNoneFalse98767.770
3574120129919NoneVOL I 2023-24. Sl. No. 15 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3628.53628.513.61FalseNoneNoneFalseNoneFalse49383.8850
3574121129919NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.00.36FalseNoneNoneFalseNoneFalse2612.520
3574122129919NoneVOL I 2023-24. Sl. No. 19 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3265.653265.650.36FalseNoneNoneFalseNoneFalse1175.6340
3574123129919NoneVOL II 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1389.251389.25125.34FalseNoneNoneFalseNoneFalse174128.5950
3574124129919NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm255.58255.58136.63FalseNoneNoneFalseNoneFalse34919.89540
3574125129919NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm295.88295.88196.41FalseNoneNoneFalseNoneFalse58113.79080
3574126129919NoneVOL II 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm106.05106.05188.8FalseNoneNoneFalseNoneFalse20022.240
3574127129919NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum104793.3104793.30.16FalseNoneNoneFalseNoneFalse16766.9280
3574128129919NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3488.13488.14.41FalseNoneNoneFalseNoneFalse15382.5210
3574129129919NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7141.47141.47.2FalseNoneNoneFalseNoneFalse51418.080
3574130129919NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1115.641115.644.0FalseNoneNoneFalseNoneFalse4462.560
3574131129919NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos108.17108.176.0FalseNoneNoneFalseNoneFalse649.020
3574132129919NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos127.26127.262.0FalseNoneNoneFalseNoneFalse254.520
3574133129919NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos251.33251.334.0FalseNoneNoneFalseNoneFalse1005.320
3574134129919NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos137.86137.864.0FalseNoneNoneFalseNoneFalse551.440
3574135129919NoneVOL 2 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1077.471077.472.0FalseNoneNoneFalseNoneFalse2154.940
3574136129919NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg194.07194.07151.2FalseNoneNoneFalseNoneFalse29343.3840
3574137129919NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1246.081246.0837.52FalseNoneNoneFalseNoneFalse46752.92160
3574138129919NoneVOL II 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2738.212738.2125.85FalseNoneNoneFalseNoneFalse70782.72850
3574139129919NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm147.41147.417.2FalseNoneNoneFalseNoneFalse1061.3520
3574140129919NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.56136.63FalseNoneNoneFalseNoneFalse22893.72280
3574141129919NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.5676.59FalseNoneNoneFalseNoneFalse12833.42040
3574142129919NoneVOL II 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm184.53184.53196.41FalseNoneNoneFalseNoneFalse36243.53730
3574143129919NoneVOL II 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm503.74503.743.6FalseNoneNoneFalseNoneFalse1813.4640
3574144129919NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne94869.1594869.151.74FalseNoneNoneFalseNoneFalse165072.3210
3574145129919NoneV-2 I.no 8.16.2 Pg.no 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m40.340.3129.3FalseNoneNoneFalseNoneFalse5210.790
17216278590001NoneNoneBuildingsMAMDAPUR SCHOOL BUILDING ELECTRIFICATION WORK139785.13
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3574146129920NoneELE SR 23-24V-6 P-III It No 1.2.1 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr69.369.3150.0FalseNoneNoneFalseNoneFalse10395.00
3574147129920NoneELE SR 23-24V-6 P-III It No 1.2.2 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr81.981.950.0FalseNoneNoneFalseNoneFalse4095.00
3574148129920NoneELE SR 23-24V-6 P-III It No 1.3.1 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr71.471.450.0FalseNoneNoneFalseNoneFalse3570.00
3574149129920NoneELE SR 23-24V-6 P-III It No 1.3.2 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr82.9582.9515.0FalseNoneNoneFalseNoneFalse1244.250
3574150129920NoneELE SR 23-24V-6 P-III It No 1.13 Pg.No 04 of 105Supplying And Fixing Metal Fan Box with Round Hook.Each122.85122.859.0FalseNoneNoneFalseNoneFalse1105.650
3574151129920NoneELE SR 23-24V-6 P-III It No 2.2.1 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch boxPoint282.45282.459.0FalseNoneNoneFalseNoneFalse2542.050
3574152129920NoneELE SR 23-24V-6 P-III It No 2.2.2 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.9513.0FalseNoneNoneFalseNoneFalse5173.350
3574153129920NoneELE SR 23-24V-6 P-III It No 2.2.3 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.753.0FalseNoneNoneFalseNoneFalse1748.250
3574154129920NoneELE SR 23-24V-6 P-III It No 2.3.2 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 1.5sqmm.Mtr27.327.3200.0FalseNoneNoneFalseNoneFalse5460.00
3574155129920NoneELE SR 23-24V-6 P-III It No 2.3.3 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 2.5sqmm.Mtr44.144.1200.0FalseNoneNoneFalseNoneFalse8820.00
3574156129920NoneELE SR 23-24V-6 P-III It No 2.3.4 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 4.0sqmm.Mtr66.1566.1530.0FalseNoneNoneFalseNoneFalse1984.50
3574157129920NoneELE SR 23-24V-6 P-III It No 3.1.1 Pg.No 08 of 105Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 WayEach134.4134.42.0FalseNoneNoneFalseNoneFalse268.80
3574158129920NoneELE SR 23-24V-6 P-III It No 3.3.3 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 WayEach143.85143.856.0FalseNoneNoneFalseNoneFalse863.10
3574159129920NoneELE SR 23-24V-6 P-III It No 3.3.5 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 - WayEach229.95229.954.0FalseNoneNoneFalseNoneFalse919.80
3574160129920NoneELE SR 23-24V-6 P-III It No 3.5.3 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4-5 ModuleEach183.75183.756.0FalseNoneNoneFalseNoneFalse1102.50
3574161129920NoneELE SR 23-24V-6 P-III It No 3.5.5 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 - ModuleEach298.2298.24.0FalseNoneNoneFalseNoneFalse1192.80
3574162129920NoneELE SR 23-24V-6 P-III It No 3.6.1 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps One way switch.Each107.1107.174.0FalseNoneNoneFalseNoneFalse7925.40
3574163129920NoneELE SR 23-24V-6 P-III It No 3.6.4 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - Stepped Fan Regulator Two ModuleEach374.85374.859.0FalseNoneNoneFalseNoneFalse3373.650
3574164129920NoneELE SR 23-24V-6 P-III It No 3.6.7Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 16 A One Way SwitchEach189.0189.03.0FalseNoneNoneFalseNoneFalse567.00
3574165129920NoneELE SR 23-24V-6 P-III It No 3.6.10Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6/16 A Universal SocketEach247.8247.89.0FalseNoneNoneFalseNoneFalse2230.20
3574166129920NoneELE SR 23-24V-6 P-III It No 3.6.11Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - TV / Telephone SocketEach163.8163.81.0FalseNoneNoneFalseNoneFalse163.80
3574167129920NoneELE SR 23-24V-6 P-III It No 3.6.12Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - RJ 45/I.O Outlet Cat-6Each353.85353.853.0FalseNoneNoneFalseNoneFalse1061.550
3574168129920NoneELE SR 23-24V-6 P-III It No 5.17.2 Pg.No 17 of 105Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. - 8-WayEach13235.2513235.251.0FalseNoneNoneFalseNoneFalse13235.250
3574169129920NoneELE SR 23-24V-6 P-III It No 5.18.1 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SPEach435.75435.752.0FalseNoneNoneFalseNoneFalse871.50
3574170129920NoneELE SR 23-24V-6 P-III It No 5.18.4 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DPEach775.95775.951.0FalseNoneNoneFalseNoneFalse775.950
3574171129920NoneELE SR 23-24V-6 P-III It No 5.19.3 Pg.No 18 of 105Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door -8 Way SP &NEach1566.61566.61.0FalseNoneNoneFalseNoneFalse1566.60
3574172129920NoneELE SR 23-24V-6 P-III It No 5.42.1Pg.No 20 of 105Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. - 14SWGSq CM0.530.532500.0FalseNoneNoneFalseNoneFalse1325.00
3574173129920NoneELE SR 23-24V-6 P-III It No 6.3.1 Pg.No 30 of 105Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.Each3133.23133.29.0FalseNoneNoneFalseNoneFalse28198.80
3574174129920NoneELE SR 23-24V-6 P-III It No 8.2.2 Pg.No 36 of 105Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2PairMtr22.0522.0550.0FalseNoneNoneFalseNoneFalse1102.50
3574175129920NoneELE SR 23-24V-6 P-III It No 8.10.2 Pg.No 37 of 105Supplying & fixing of I/O socket with back box - Double I/oEach577.5577.53.0FalseNoneNoneFalseNoneFalse1732.50
3574176129920NoneELE SR 23-24 V-6 P-III It No 8.11.2 Pg.No 37Supplying & Fixing of …mtrs Cat6 Patch Cable - 2mtrEach269.85269.853.0FalseNoneNoneFalseNoneFalse809.550
3574177129920NoneELE SR 23-24V-6 P-III It No 8.12.3 Pg.No 37 of 105Supplying & Fixing of Patch panel for LAN cabling - 16 Port 10/100 patch panelEach3202.53202.51.0FalseNoneNoneFalseNoneFalse3202.50
3574178129920NoneELE SR 23-24V-6 P-III It No 8.13.1 Pg.No 37 of 105Supplying and fixing of MDF krone junction box with KRONE Module / Telephone - cable termination. - 10 Pairm362.25362.253.0FalseNoneNoneFalseNoneFalse1086.750
3574179129920NoneELE SR 23-24V-6 P-III It No 11.3.2 Pg.No 43 of 105Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4'- 20/22 wEach724.5724.512.0FalseNoneNoneFalseNoneFalse8694.00
3574180129920NoneELE SR 23-24V-6 P-III It No 13.7.1 Pg.No 56 of 105Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / GirdersEach128.1128.112.0FalseNoneNoneFalseNoneFalse1537.20
3574181129920NoneELE SR 23-24V-6 P-III It No 13.10 Pg.No 56 of 105Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.559.0FalseNoneNoneFalseNoneFalse1615.950
3574182129920NoneUNISR 23-24 Esc V-6 P-II Sno.197 IN.32.1 Pg.No 13Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 6 sqmmKm66576.366576.30.03FalseNoneNoneFalseNoneFalse1997.2890
3574183129920NoneUNISR 2023-24 EscV-6 P-II Sno. 167 I.N 20.05 Pg.52Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 2.5 sqmm to 25 sqmmKm1246.351246.350.03FalseNoneNoneFalseNoneFalse37.39050
3574184129920NoneUNISR 21-22 BSC V-6 P-II Sno. 201 I.N 29.02 Pg 08Earth work Excavation for cable trench of 0.5m to 0.75 mtr width and Depth upto 1 Mtrs including trial pits, depositing on bank upto a lead of 50 Mtrs , Supplying and Displaying necessary Danger Boards and Lighting , Using sight Rails and Sign Boards at every 100 Mtrs wherever necessary as directed. In soil (Ordinary) (1x70x0.50x0.75 = 26.25 CMT)Cum273.0273.07.5FalseNoneNoneFalseNoneFalse2047.50
3574185129920NoneUNICSR 21-22 BES V-6 P-II Sno. 206 I.N 29.07 Pg.08Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. (1x70x0.50x0.75 = 26.25 CMT)Cum60.960.97.5FalseNoneNoneFalseNoneFalse456.750
3574186129920NoneELE SR 23-24V-6 P-III It No 12.57 Pg.No 55 of 105Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each3685.53685.51.0FalseNoneNoneFalseNoneFalse3685.50
17216278590001NoneNoneBuildingsCONSTRUCTION OF NEW GOVT HIGH SCHOOL BUILDING AND TOILET AT GARALDINNI VILLAGE AND CONSTRUCTION OF 3 CLASS ROOM TO GOVT HIGHER PRIMARY SCHOOL AT MAMDAPUR VILLAGE IN RAICHUR TALUKA, RAICHUR DISTRICT. UNDER KKRDB - MACRO (GENERAL) FOR THE YEAR 2023-24 (Work code RCH2317133389).25839556.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3574187129921NoneELE SR 23-24V-6 P-III It No 1.2.1 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr69.369.3850.0FalseNoneNoneFalseNoneFalse58905.00
3574188129921NoneELE SR 23-24V-6 P-III It No 1.2.1 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr69.369.3150.0FalseNoneNoneFalseNoneFalse10395.00
3574189129921NoneV-5 WS & SB 2023-24. Sl No. 21.1.1 P.No.247Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componentsEach26250.026250.01.0FalseNoneNoneFalseNoneFalse26250.00
3574190129921NoneVOL I 2023-24. I. No. 1.12 P.No. 08)Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (PWD CSR VOL I for the year 2023-24. I. No. 1.12 P.No. 08)Cum99.7599.7548.6FalseNoneNoneFalseNoneFalse4847.850
3574191129921NoneVOL I 2023-24. I. No. 1.14.1 P.No. 08 )Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR VOL I for the year 2023-24. I. No. 1.14.1 P.No. 08 )Cum107.1107.1100.0FalseNoneNoneFalseNoneFalse10710.00
3574192129921NoneVOL I 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6593.136593.132.19FalseNoneNoneFalseNoneFalse14438.95470
3574193129921NoneVOL I 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6593.136593.130.69FalseNoneNoneFalseNoneFalse4549.25970
3574194129921NoneVOL I for the year 2023-24. I. No. 1.12 P.No. 08)Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (PWD CSR VOL I for the year 2023-24. I. No. 1.12 P.No. 08)Cum99.7599.75315.0FalseNoneNoneFalseNoneFalse31421.250
3574195129921NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6658.416658.412.2FalseNoneNoneFalseNoneFalse14648.5020
3574196129921NoneVOL I I. No. 2.5.2 P.No. 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7400.77400.71.32FalseNoneNoneFalseNoneFalse9768.9240
3574197129921NoneELE SR 23-24V-6 P-III It No 1.2.2 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr81.981.9200.0FalseNoneNoneFalseNoneFalse16380.00
3574198129921NoneELE SR 23-24V-6 P-III It No 1.2.2 Pg.No 02 of 105Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr81.981.950.0FalseNoneNoneFalseNoneFalse4095.00
3574199129921NoneVOL I 2023-24. I. No. 1.14.1 P.No. 08 )Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR VOL I for the year 2023-24. I. No. 1.14.1 P.No. 08 )Cum107.1107.1640.18FalseNoneNoneFalseNoneFalse68563.2780
3574200129921NoneVOL I 2023-24. I. No. 1.14.1 P.No. 08 )Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR VOL I for the year 2023-24. I. No. 1.14.1 P.No. 08 )Cum107.1107.162.67FalseNoneNoneFalseNoneFalse6711.9570
3574201129921NoneVOL I 2023-24. I. No. 2.1.3 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15)Cum6288.456288.453.75FalseNoneNoneFalseNoneFalse23581.68750
3574202129921NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3955.883955.882.19FalseNoneNoneFalseNoneFalse8663.37720
3574203129921NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3955.883955.880.69FalseNoneNoneFalseNoneFalse2729.55720
3574204129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3995.043995.042.2FalseNoneNoneFalseNoneFalse8789.0880
3574205129921NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5180.495180.491.32FalseNoneNoneFalseNoneFalse6838.24680
3574206129921NoneVOL II 2023-24. I. No. 13.34 Page No 123 )Providing and placing on terrace (at all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tankl9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3574207129921NoneELE SR 23-24V-6 P-III It No 1.3.1 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr71.471.4280.0FalseNoneNoneFalseNoneFalse19992.00
3574208129921NoneELE SR 23-24V-6 P-III It No 1.3.1 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr71.471.450.0FalseNoneNoneFalseNoneFalse3570.00
3574209129921NoneVOL I 2023-24. I. No. 1.4.1 P.No. 05)Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD CSR VOL I for the year 2023-24. I. No. 1.4.1 P.No. 05)Cum254.1254.126.09FalseNoneNoneFalseNoneFalse6629.4690
3574210129921NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.83.22FalseNoneNoneFalseNoneFalse21422.0160
3574211129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.01.11FalseNoneNoneFalseNoneFalse8055.270
3574212129921NoneVOL I for the year 2023-24. I. No. 1.4.1 P.No. 05)Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD CSR VOL I for the year 2023-24. I. No. 1.4.1 P.No. 05)Cum254.1254.118.09FalseNoneNoneFalseNoneFalse4596.6690
3574213129921NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6723.686723.683.43FalseNoneNoneFalseNoneFalse23062.22240
3574214129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.05.68FalseNoneNoneFalseNoneFalse41219.760
3574215129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.855.51FalseNoneNoneFalseNoneFalse40381.96350
3574216129921NoneVOL II 2023-24. I. No. 13.33.5 Page No 123)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 40MM Dia Pipe over terrace distribution from TankMtr500.85500.8585.0FalseNoneNoneFalseNoneFalse42572.250
3574217129921NoneELE SR 23-24V-6 P-III It No 1.3.2 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr82.9582.9575.0FalseNoneNoneFalseNoneFalse6221.250
3574218129921NoneELE SR 23-24V-6 P-III It No 1.3.2 Pg.No 02 of 105Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr82.9582.9515.0FalseNoneNoneFalseNoneFalse1244.250
3574219129921NoneVOL 1 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.25.68FalseNoneNoneFalseNoneFalse24731.8560
3574220129921NoneVOL I 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6527.856527.852.13FalseNoneNoneFalseNoneFalse13904.32050
3574221129921NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.21.11FalseNoneNoneFalseNoneFalse4833.1620
3574222129921NoneVOL I 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3326.43326.43.22FalseNoneNoneFalseNoneFalse10711.0080
3574223129921NoneVOL I for the year 2023-24. I. No. 1.23 P.No. 11)Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. (PWD CSR VOL I for the year 2023-24. I. No. 1.23 P.No. 11)Cum2816.12816.191.46FalseNoneNoneFalseNoneFalse257560.5060
3574224129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4397.314397.315.51FalseNoneNoneFalseNoneFalse24229.17810
3574225129921NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum4706.584706.583.43FalseNoneNoneFalseNoneFalse16143.56940
3574226129921NoneVOL II 2023-24. I. No. 13.33.4 Page No 122)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 32MM DiaMtr390.6390.685.0FalseNoneNoneFalseNoneFalse33201.00
3574227129921NoneELE SR 23-24V-6 P-III It No 1.13 Pg.No 04 of 105Supplying And Fixing Metal Fan Box with Round Hook.Each122.85122.8541.0FalseNoneNoneFalseNoneFalse5036.850
3574228129921NoneELE SR 23-24V-6 P-III It No 1.13 Pg.No 04 of 105Supplying And Fixing Metal Fan Box with Round Hook.Each122.85122.859.0FalseNoneNoneFalseNoneFalse1105.650
3574229129921NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.85.4FalseNoneNoneFalseNoneFalse35925.120
3574230129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7257.07257.03.98FalseNoneNoneFalseNoneFalse28882.860
3574231129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7257.07257.02.7FalseNoneNoneFalseNoneFalse19593.90
3574232129921NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3916.713916.712.13FalseNoneNoneFalseNoneFalse8342.59230
3574233129921NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6527.856527.851.43FalseNoneNoneFalseNoneFalse9334.82550
3574234129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7328.857328.853.98FalseNoneNoneFalseNoneFalse29168.8230
3574235129921NoneVOL II 2023-24. I. No. 13.32.3 Page No 122)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 25MM Dia PipeMtr500.85500.8585.0FalseNoneNoneFalseNoneFalse42572.250
3574236129921NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1416.761416.7642.73FalseNoneNoneFalseNoneFalse60538.15480
3574237129921NoneELE SR 23-24V-6 P-III It No 2.2.1 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch boxPoint282.45282.4542.0FalseNoneNoneFalseNoneFalse11862.90
3574238129921NoneELE SR 23-24V-6 P-III It No 2.2.1 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch boxPoint282.45282.459.0FalseNoneNoneFalseNoneFalse2542.050
3574239129921NoneVOL I 2023-24. I. No. 2.1.3 P.No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15)Cum6288.456288.4519.89FalseNoneNoneFalseNoneFalse125077.27050
3574240129921NoneVOL I 2023-24. Sl. No. 11 P.No. 112)Appendix I Additionalities for Formwork, Centering & Scaffolding for Earth retaining structures 10% (PWD CSR VOL I for the year 2023-24. Sl. No. 11 P.No. 112)Cum665.28665.285.4FalseNoneNoneFalseNoneFalse3592.5120
3574241129921NoneVOL I 2023-24. Sl. No. 9 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5079.95079.92.7FalseNoneNoneFalseNoneFalse13715.730
3574242129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3916.713916.711.43FalseNoneNoneFalseNoneFalse5600.89530
3574243129921NoneVOL I for the year 2023-24. Sl. No. 16 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3628.53628.53.98FalseNoneNoneFalseNoneFalse14441.430
3574244129921NoneVOL I for the year 2023-24. Sl. No. 16 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3664.433664.433.98FalseNoneNoneFalseNoneFalse14584.43140
3574245129921NoneVOL II 2023-24. I. No. 13.32.2 Page No 122)Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 20MM Dia PipeMtr397.95397.9585.0FalseNoneNoneFalseNoneFalse33825.750
3574246129921NoneVOL II for the year 2023-24. I. No. 6.34 P.No. 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1193.971193.97103.58FalseNoneNoneFalseNoneFalse123671.41260
3574247129921NoneELE SR 23-24V-6 P-III It No 2.2.2 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.9558.0FalseNoneNoneFalseNoneFalse23081.10
3574248129921NoneELE SR 23-24V-6 P-III It No 2.2.2 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPoint397.95397.9513.0FalseNoneNoneFalseNoneFalse5173.350
3574249129921NoneVOL I 023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7257.07257.013.19FalseNoneNoneFalseNoneFalse95719.830
3574250129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.03.17FalseNoneNoneFalseNoneFalse23004.690
3574251129921NoneVOL I for the year 2023-24. I. No. 2.1.3 P.No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15)Cum6288.456288.4594.18FalseNoneNoneFalseNoneFalse592246.2210
3574252129921NoneVOL I for the year 2023-24. I. No. 2.1.4 P.No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6723.686723.680.88FalseNoneNoneFalseNoneFalse5916.83840
3574253129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7328.857328.8513.19FalseNoneNoneFalseNoneFalse96667.53150
3574254129921NoneVOL II 2023-24. I. No. 13.2.1 Page No 117)Providing and fixing brass bib cock of approved quality : 15 mm nominal boreEach300.3300.330.0FalseNoneNoneFalseNoneFalse9009.00
3574255129921NoneVOL II 2023-24. I. No. 5.1.1 P.No. 9)Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 5.1.1 P.No. 9)Cum5891.555891.5512.74FalseNoneNoneFalseNoneFalse75058.3470
3574256129921NoneVOL II 2023-24. I. No. 8.8 P.No. 42)Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.8 P.No. 42)Sqm389.55389.5554.0FalseNoneNoneFalseNoneFalse21035.70
3574257129921NoneELE SR 23-24V-6 P-III It No 2.2.3 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.7512.0FalseNoneNoneFalseNoneFalse6993.00
3574258129921NoneELE SR 23-24V-6 P-III It No 2.2.3 Pg.No 05 of 105Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPoint582.75582.753.0FalseNoneNoneFalseNoneFalse1748.250
3574259129921NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.23.17FalseNoneNoneFalseNoneFalse13802.8140
3574260129921NoneVOL I for the year 2023-24. I. No. 1.11 P.No. 07)Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. (PWD CSR VOL I for the year 2023-24. I. No. 1.11 P.No. 07)Cum454.65454.65859.72FalseNoneNoneFalseNoneFalse390871.6980
3574261129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4034.214034.210.88FalseNoneNoneFalseNoneFalse3550.10480
3574262129921NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5079.95079.913.19FalseNoneNoneFalseNoneFalse67003.8810
3574263129921NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5130.195130.1913.19FalseNoneNoneFalseNoneFalse67667.20610
3574264129921NoneVOL II 2023-24. I. No. 13.3.2 Page No 117Providing and fixing brass stop cock of approved quality : 20 mm nominal boreEach320.25320.2510.0FalseNoneNoneFalseNoneFalse3202.50
3574265129921NoneVOL II 2023-24. I. No. 15.6 P.No. 150)Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification (PWD SR for Buildings VOL II for the year 2023-24. I. No. 15.6 P.No. 150)Sqm532.35532.3554.0FalseNoneNoneFalseNoneFalse28746.90
3574266129921NoneVOL II 2023-24. I. No. 5.2 & P.No. 9)Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ( PWD SR for Buildings VOL II for the year 2023-24. I. No. 5.2 & P.No. 9)Cum6948.96948.912.33FalseNoneNoneFalseNoneFalse85679.9370
3574267129921NoneELE SR 23-24V-6 P-III It No 2.3.2 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 1.5sqmm.Mtr27.327.31850.0FalseNoneNoneFalseNoneFalse50505.00
3574268129921NoneELE SR 23-24V-6 P-III It No 2.3.2 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 1.5sqmm.Mtr27.327.3200.0FalseNoneNoneFalseNoneFalse5460.00
3574269129921NoneV-5 CSR 2023-24. Sl No. 18.3 P.No.150)Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.. (WS & Sewerage Works CSR for the year 2023-24. Sl No. 18.3 P.No.150)Cum2060.12060.11.0FalseNoneNoneFalseNoneFalse2060.10
3574270129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.018.82FalseNoneNoneFalseNoneFalse136576.740
3574271129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.013.61FalseNoneNoneFalseNoneFalse98767.770
3574272129921NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.897.6FalseNoneNoneFalseNoneFalse649313.280
3574273129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.8518.82FalseNoneNoneFalseNoneFalse137928.9570
3574274129921NoneVOL II 2023-24. I. No. 14.7.2 Page No 132)Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tapUnit2689.052689.0510.0FalseNoneNoneFalseNoneFalse26890.50
3574275129921NoneVOL II 2023-24. I. No. 8.19.1 P.No. 44)Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.19.1 P.No. 44)Cum267.75267.7539.19FalseNoneNoneFalseNoneFalse10493.12250
3574276129921NoneVOL II for the year 2023-24. I. No. 8.1.2 P.No. 41Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm260.64260.6446.99FalseNoneNoneFalseNoneFalse12247.47360
3574277129921NoneELE SR 23-24V-6 P-III It No 2.3.3 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 2.5sqmm.Mtr44.144.11850.0FalseNoneNoneFalseNoneFalse81585.00
3574278129921NoneELE SR 23-24V-6 P-III It No 2.3.3 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 2.5sqmm.Mtr44.144.1200.0FalseNoneNoneFalseNoneFalse8820.00
3574279129921NoneVOL I 2023-24. I. No. 1.11 P.No. 07)Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. (PWD CSR VOL I for the year 2023-24. I. No. 1.11 P.No. 07)Cum454.65454.65144.19FalseNoneNoneFalseNoneFalse65555.98350
3574280129921NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)t93929.8593929.850.78FalseNoneNoneFalseNoneFalse73265.2830
3574281129921NoneVOL I 2023-24. Sl. No. 15 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3628.53628.513.61FalseNoneNoneFalseNoneFalse49383.8850
3574282129921NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for isolated footings 8%. (PWD CSR VOL I for the year 2023-24. Sl. No. 1(b) P.No. 111)Cum532.22532.2297.6FalseNoneNoneFalseNoneFalse51944.6720
3574283129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4354.24354.218.82FalseNoneNoneFalseNoneFalse81946.0440
3574284129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4397.314397.3118.82FalseNoneNoneFalseNoneFalse82757.37420
3574285129921NoneVOL II 2023-24. I. No. 13.8.2.2 Page No. 118)Providing and fixing unplasticised PVC connection pipe with brass unions : 20 mm nominal boreSet115.5115.510.0FalseNoneNoneFalseNoneFalse1155.00
3574286129921NoneVOL II for the year 2023-24. I. No. 8.2.2 P.No. 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm301.74301.74475.61FalseNoneNoneFalseNoneFalse143510.56140
3574287129921NoneELE SR 23-24V-6 P-III It No 2.3.4 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 4.0sqmm.Mtr66.1566.15200.0FalseNoneNoneFalseNoneFalse13230.00
3574288129921NoneELE SR 23-24V-6 P-III It No 2.3.4 Pg.No 05 of 105Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 4.0sqmm.Mtr66.1566.1530.0FalseNoneNoneFalseNoneFalse1984.50
3574289129921NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.812.6FalseNoneNoneFalseNoneFalse83825.280
3574290129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.067.27FalseNoneNoneFalseNoneFalse488178.390
3574291129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.00.36FalseNoneNoneFalseNoneFalse2612.520
3574292129921NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.85.4FalseNoneNoneFalseNoneFalse35925.120
3574293129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.8567.27FalseNoneNoneFalseNoneFalse493011.73950
3574294129921NoneVOL II 2023-24. I. No. 14.24 Page No. 117)Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.Each2976.752976.753.0FalseNoneNoneFalseNoneFalse8930.250
3574295129921NoneVOL II 2023-24. I. No. 8.51 P.No. 50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm108.15108.1546.99FalseNoneNoneFalseNoneFalse5081.96850
3574296129921NoneELE SR 23-24V-6 P-III It No 3.1.1 Pg.No 08 of 105Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 WayEach134.4134.44.0FalseNoneNoneFalseNoneFalse537.60
3574297129921NoneELE SR 23-24V-6 P-III It No 3.1.1 Pg.No 08 of 105Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 WayEach134.4134.42.0FalseNoneNoneFalseNoneFalse268.80
3574298129921NoneVOL I 2023-24. Sl. No. 1(b) P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for isolated footings 8%. (PWD CSR VOL I for the year 2023-24. Sl. No. 1(b) P.No. 111)Cum532.22532.2212.6FalseNoneNoneFalseNoneFalse6705.9720
3574299129921NoneVOL I 2023-24. Sl. No. 19 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3265.653265.650.36FalseNoneNoneFalseNoneFalse1175.6340
3574300129921NoneVOL I for the year 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3628.53628.567.27FalseNoneNoneFalseNoneFalse244089.1950
3574301129921NoneVOL I for the year 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3664.423664.4267.27FalseNoneNoneFalseNoneFalse246505.53340
3574302129921NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum4656.964656.965.4FalseNoneNoneFalseNoneFalse25147.5840
3574303129921NoneVOL II 2023-24. I. No. 11.5.2 P.No. 77Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.5.2 P.No. 77)Sqm4587.724587.721.74FalseNoneNoneFalseNoneFalse7982.63280
3574304129921NoneVOL II 2023-24. I. No. 14.29 Page No. 136)Providing and fixing 100 mm sand cast Iron grating for gully trap.Each49.3549.353.0FalseNoneNoneFalseNoneFalse148.050
3574305129921NoneELE SR 23-24V-6 P-III It No 3.3.3 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 WayEach143.85143.8522.0FalseNoneNoneFalseNoneFalse3164.70
3574306129921NoneELE SR 23-24V-6 P-III It No 3.3.3 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 WayEach143.85143.856.0FalseNoneNoneFalseNoneFalse863.10
3574307129921NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.81.43FalseNoneNoneFalseNoneFalse9513.5040
3574308129921NoneVOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.834.95FalseNoneNoneFalseNoneFalse232515.360
3574309129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7257.07257.01.96FalseNoneNoneFalseNoneFalse14223.720
3574310129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7328.857328.851.76FalseNoneNoneFalseNoneFalse12898.7760
3574311129921NoneVOL II 2023-24. I. No. 10.8 Page No. 70)Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm2928.452928.4528.08FalseNoneNoneFalseNoneFalse82230.8760
3574312129921NoneVOL II 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1389.251389.25125.34FalseNoneNoneFalseNoneFalse174128.5950
3574313129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm170.87170.8746.99FalseNoneNoneFalseNoneFalse8029.18130
3574314129921NoneELE SR 23-24V-6 P-III It No 3.3.5 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 - WayEach229.95229.9520.0FalseNoneNoneFalseNoneFalse4599.00
3574315129921NoneELE SR 23-24V-6 P-III It No 3.3.5 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 - WayEach229.95229.954.0FalseNoneNoneFalseNoneFalse919.80
3574316129921NoneVOL I 2023-24. Sl. No. 9 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum4656.964656.961.43FalseNoneNoneFalseNoneFalse6659.45280
3574317129921NoneVOL I for the year 2023-24. Sl. No. 19 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3265.653265.651.96FalseNoneNoneFalseNoneFalse6400.6740
3574318129921NoneVOL I for the year 2023-24. Sl. No. 19 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3297.983297.981.76FalseNoneNoneFalseNoneFalse5804.44480
3574319129921NoneVOL I for the year 2023-24. Sl. No. 2 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings 50%. (PWD CSR VOL I for the year 2023-24. Sl. No. 2 P.No. 111)Cum3326.43326.434.95FalseNoneNoneFalseNoneFalse116257.680
3574320129921NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm255.58255.58136.63FalseNoneNoneFalseNoneFalse34919.89540
3574321129921NoneVOL II 2023-24.I. No. 14.5.1 Page No. 132)Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach9074.19074.13.0FalseNoneNoneFalseNoneFalse27222.30
3574322129921NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm188.18188.18475.61FalseNoneNoneFalseNoneFalse89500.28980
3574323129921NoneELE SR 23-24V-6 P-III It No 3.3.6 Pg.No 08 of 105Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 WayEach274.05274.0514.0FalseNoneNoneFalseNoneFalse3836.70
3574324129921NoneELE SR 23-24V-6 P-III It No 3.5.3 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4-5 ModuleEach183.75183.756.0FalseNoneNoneFalseNoneFalse1102.50
3574325129921NoneVOL I 2023-24. I. No. 2.2.3 P.No. 15)Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.85.63FalseNoneNoneFalseNoneFalse37455.2640
3574326129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.1514.73FalseNoneNoneFalseNoneFalse105837.25950
3574327129921NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm295.88295.88196.41FalseNoneNoneFalseNoneFalse58113.79080
3574328129921NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1389.251389.25458.63FalseNoneNoneFalseNoneFalse637151.72750
3574329129921NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1403.011403.01408.25FalseNoneNoneFalseNoneFalse572778.83250
3574330129921NoneVOL II for the year 2023-24. I. No. 7.19 P.No. 23Providing and laying to required line and slope roofing with semicorrugated ( Trafford ) asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers, over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 7.19 P.No. 23)Sqm404.48404.4832.08FalseNoneNoneFalseNoneFalse12975.71840
3574331129921NoneVOL II I. No. 14.1.1 Page No. 131)Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.27.0FalseNoneNoneFalseNoneFalse35897.40
3574332129921NoneELE SR 23-24V-6 P-III It No 3.5.3 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4-5 ModuleEach183.75183.7522.0FalseNoneNoneFalseNoneFalse4042.50
3574333129921NoneELE SR 23-24V-6 P-III It No 3.5.5 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 - ModuleEach298.2298.24.0FalseNoneNoneFalseNoneFalse1192.80
3574334129921NoneVOL 2 2023-24. I. No. 11.25.2 P.No. 84Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.25.2 P.No. 84)Kg147.08147.08351.04FalseNoneNoneFalseNoneFalse51630.96320
3574335129921NoneVOL I 2023-24. Sl. No. 2 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Plinth Beams of Buildings 50%. (PWD CSR VOL I for the year 2023-24. Sl. No. 2 P.No. 111)Cum3326.43326.45.63FalseNoneNoneFalseNoneFalse18727.6320
3574336129921NoneVOL I for the year 2023-24. Sl. No. 9 P.No. 111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5029.65029.614.73FalseNoneNoneFalseNoneFalse74086.0080
3574337129921NoneVOL II 2023-24. I. No. 13.59 Page No. 127)Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach231.0231.025.0FalseNoneNoneFalseNoneFalse5775.00
3574338129921NoneVOL II 2023-24. I. No. 6.34 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1170.791170.7930.07FalseNoneNoneFalseNoneFalse35205.65530
3574339129921NoneVOL II 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm106.05106.05188.8FalseNoneNoneFalseNoneFalse20022.240
3574340129921NoneVOL II for the year 2023-24. I. No. 6.34 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1182.381182.3857.55FalseNoneNoneFalseNoneFalse68045.9690
3574341129921NoneELE SR 23-24V-6 P-III It No 3.5.5 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 - ModuleEach298.2298.220.0FalseNoneNoneFalseNoneFalse5964.00
3574342129921NoneELE SR 23-24V-6 P-III It No 3.6.1 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps One way switch.Each107.1107.174.0FalseNoneNoneFalseNoneFalse7925.40
3574343129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.154.77FalseNoneNoneFalseNoneFalse34273.16550
3574344129921NoneVOL I 2023-24.I. No. 1.15.1 Page No. 08)Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum381.15381.1546.8FalseNoneNoneFalseNoneFalse17837.820
3574345129921NoneVOL I for the year 2023-24. I. No. 2.11.a P.No. 18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)t96747.7496747.740.2FalseNoneNoneFalseNoneFalse19349.5480
3574346129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.57185.55.72FalseNoneNoneFalseNoneFalse41101.060
3574347129921NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum104793.3104793.30.16FalseNoneNoneFalseNoneFalse16766.9280
3574348129921NoneVOL II 2023-24. I. No. 6.16 P.No. 15)Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.16 P.No. 15)Sqm100.75100.7530.07FalseNoneNoneFalseNoneFalse3029.55250
3574349129921NoneVOL II for the year 2023-24. I. No. 6.16 P.No. 15)Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.16 P.No. 15)Sqm101.74101.7457.55FalseNoneNoneFalseNoneFalse5855.1370
3574350129921NoneELE SR 23-24V-6 P-III It No 3.5.6 Pg.No 08 of 105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleEach361.2361.214.0FalseNoneNoneFalseNoneFalse5056.80
3574351129921NoneELE SR 23-24V-6 P-III It No 3.6.4 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - Stepped Fan Regulator Two ModuleEach374.85374.859.0FalseNoneNoneFalseNoneFalse3373.650
3574352129921NoneV-2 I.NO 8.16.2 PG.NO 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m41.141.128.8FalseNoneNoneFalseNoneFalse1183.680
3574353129921NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3488.13488.14.41FalseNoneNoneFalseNoneFalse15382.5210
3574354129921NoneVOL I 2023-24. Sl. No. 9 P.No. 111)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5029.65029.64.77FalseNoneNoneFalseNoneFalse23991.1920
3574355129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.095.72FalseNoneNoneFalseNoneFalse24659.43480
3574356129921NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm258.11258.11610.42FalseNoneNoneFalseNoneFalse157555.50620
3574357129921NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm255.58255.58770.77FalseNoneNoneFalseNoneFalse196993.39660
3574358129921NoneVOL II 2023-24.I. No. 13.53 Page No. 126)Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Each5924.15924.112.0FalseNoneNoneFalseNoneFalse71089.20
3574359129921NoneELE SR 23-24V-6 P-III It No 3.6.1 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps One way switch.Each107.1107.184.0FalseNoneNoneFalseNoneFalse8996.40
3574360129921NoneELE SR 23-24V-6 P-III It No 3.6.7Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 16 A One Way SwitchEach189.0189.03.0FalseNoneNoneFalseNoneFalse567.00
3574361129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.57185.51.57FalseNoneNoneFalseNoneFalse11281.2350
3574362129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.153.98FalseNoneNoneFalseNoneFalse28596.8970
3574363129921NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7141.47141.47.2FalseNoneNoneFalseNoneFalse51418.080
3574364129921NoneVOL II 2023-24. I. No. 13.64.3 P.No. 128 )Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipesMtr806.4806.440.0FalseNoneNoneFalseNoneFalse32256.00
3574365129921NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm295.88295.88628.66FalseNoneNoneFalseNoneFalse186007.92080
3574366129921NoneVOL II for the year 2023-24. I. No. 8.2.2 P.No. 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm298.81298.81591.54FalseNoneNoneFalseNoneFalse176758.06740
3574367129921NoneELE SR 23-24V-6 P-III It No 3.6.10Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6/16 A Universal SocketEach247.8247.89.0FalseNoneNoneFalseNoneFalse2230.20
3574368129921NoneELE SR 23-24V-6 P-III It No 3.6.4 Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - Stepped Fan Regulator Two ModuleEach374.85374.8541.0FalseNoneNoneFalseNoneFalse15368.850
3574369129921NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.091.57FalseNoneNoneFalseNoneFalse6768.41130
3574370129921NoneVOL I for the year 2023-24. Sl. No. 16 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3592.573592.573.98FalseNoneNoneFalseNoneFalse14298.42860
3574371129921NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1115.641115.644.0FalseNoneNoneFalseNoneFalse4462.560
3574372129921NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm295.88295.8839.85FalseNoneNoneFalseNoneFalse11790.8180
3574373129921NoneVOL II 2023-24.I. No. 13.64.2 Page No. 128)Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesMtr404.25404.25120.0FalseNoneNoneFalseNoneFalse48510.00
3574374129921NoneVOL II for the year 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm107.1107.11017.08FalseNoneNoneFalseNoneFalse108929.2680
3574375129921NoneELE SR 23-24V-6 P-III It No 3.6.11Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - TV / Telephone SocketEach163.8163.81.0FalseNoneNoneFalseNoneFalse163.80
3574376129921NoneELE SR 23-24V-6 P-III It No 3.6.7Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 16 A One Way SwitchEach189.0189.010.0FalseNoneNoneFalseNoneFalse1890.00
3574377129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates]Cum7185.157185.153.1FalseNoneNoneFalseNoneFalse22273.9650
3574378129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1518.88FalseNoneNoneFalseNoneFalse135655.6320
3574379129921NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum105830.86105830.860.82FalseNoneNoneFalseNoneFalse86781.30520
3574380129921NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos108.17108.176.0FalseNoneNoneFalseNoneFalse649.020
3574381129921NoneVOL II 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm106.05106.051253.23FalseNoneNoneFalseNoneFalse132905.04150
3574382129921NoneVOL II 2023-24.I. No. 13.48 Page No. 125)Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterm305.55305.5596.0FalseNoneNoneFalseNoneFalse29332.80
3574383129921NoneELE SR 23-24V-6 P-III It No 3.6.10Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6/16 A Universal SocketEach247.8247.830.0FalseNoneNoneFalseNoneFalse7434.00
3574384129921NoneELE SR 23-24V-6 P-III It No 3.6.12Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - RJ 45/I.O Outlet Cat-6Each353.85353.853.0FalseNoneNoneFalseNoneFalse1061.550
3574385129921NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3557.863557.8623.73FalseNoneNoneFalseNoneFalse84428.01780
3574386129921NoneVOL I 2023-24. Sl. No. 16 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Staircase and other similar structures 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 16 P.No. 112)Cum3592.573592.573.1FalseNoneNoneFalseNoneFalse11136.9670
3574387129921NoneVOL I 2023-24.I. No. 2.1.3 Page No. 15)Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.452.0FalseNoneNoneFalseNoneFalse12576.90
3574388129921NoneVOL I for the year 2023-24. Sl. No. 14 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.0918.88FalseNoneNoneFalseNoneFalse81393.37920
3574389129921NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum104793.31104793.310.91FalseNoneNoneFalseNoneFalse95361.91210
3574390129921NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos127.26127.262.0FalseNoneNoneFalseNoneFalse254.520
3574391129921NoneELE SR 23-24V-6 P-III It No 3.6.11Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - TV / Telephone SocketEach163.8163.82.0FalseNoneNoneFalseNoneFalse327.60
3574392129921NoneELE SR 23-24V-6 P-III It No 5.17.2 Pg.No 17 of 105Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. - 8-WayEach13235.2513235.251.0FalseNoneNoneFalseNoneFalse13235.250
3574393129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.154.93FalseNoneNoneFalseNoneFalse35422.78950
3574394129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1571.16FalseNoneNoneFalseNoneFalse511295.2740
3574395129921NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7212.117212.1143.2FalseNoneNoneFalseNoneFalse311563.1520
3574396129921NoneVOL II 2023-24. I. No. 12.54 P.No. 104)Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.54 P.No. 104)Sqm337.24337.2417.1FalseNoneNoneFalseNoneFalse5766.8040
3574397129921NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos251.33251.334.0FalseNoneNoneFalseNoneFalse1005.320
3574398129921NoneVOL II 2023-24.I. No. 6.32 Page No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.538.79FalseNoneNoneFalseNoneFalse53355.6450
3574399129921NoneELE SR 23-24V-6 P-III It No 3.6.12Pg.No 09 of 105Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - RJ 45/I.O Outlet Cat-6Each353.85353.8510.0FalseNoneNoneFalseNoneFalse3538.50
3574400129921NoneELE SR 23-24V-6 P-III It No 5.18.1 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SPEach435.75435.752.0FalseNoneNoneFalseNoneFalse871.50
3574401129921NoneV-II 2023-24 I. No. 6.34 P.No. 07Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.25.4FalseNoneNoneFalseNoneFalse6259.680
3574402129921NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3522.983522.9826.1FalseNoneNoneFalseNoneFalse91949.7780
3574403129921NoneVOL I 2023-24. Sl. No. 14 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.094.93FalseNoneNoneFalseNoneFalse21253.67370
3574404129921NoneVOL I for the year 2023-24. Sl. No. 15 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3592.583592.5871.16FalseNoneNoneFalseNoneFalse255647.99280
3574405129921NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1126.691126.6920.0FalseNoneNoneFalseNoneFalse22533.80
3574406129921NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos137.86137.864.0FalseNoneNoneFalseNoneFalse551.440
3574407129921NoneELE SR 23-24V-6 P-III It No 5.18.4 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DPEach775.95775.951.0FalseNoneNoneFalseNoneFalse775.950
3574408129921NoneELE SR 23-24V-6 P-III It No 5.8.1 Pg.No 15 of 105Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. - 63AmpsEach2427.62427.61.0FalseNoneNoneFalseNoneFalse2427.60
3574409129921NoneVOL 2 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1077.471077.472.0FalseNoneNoneFalseNoneFalse2154.940
3574410129921NoneVOL I 2023-24 I. No. 2.5.2 P.No. 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.151.52FalseNoneNoneFalseNoneFalse10921.4280
3574411129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1518.57FalseNoneNoneFalseNoneFalse133428.23550
3574412129921NoneVOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.152.2FalseNoneNoneFalseNoneFalse15807.330
3574413129921NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos109.24109.2466.0FalseNoneNoneFalseNoneFalse7209.840
3574414129921NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7141.417141.4139.6FalseNoneNoneFalseNoneFalse282799.8360
3574415129921NoneELE SR 23-24V-6 P-III It No 5.17.3 Pg.No 17 of 105Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. - 12-WayEach16305.4516305.452.0FalseNoneNoneFalseNoneFalse32610.90
3574416129921NoneELE SR 23-24V-6 P-III It No 5.19.3 Pg.No 18 of 105Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door -8 Way SP &NEach1566.61566.61.0FalseNoneNoneFalseNoneFalse1566.60
3574417129921NoneVOL I 2023-24. Sl. No. 15 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3592.583592.5818.57FalseNoneNoneFalseNoneFalse66714.21060
3574418129921NoneVOL I for the year 2023-24 I. No. 15 P.No.112Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50%Cum3592.583592.5815.15FalseNoneNoneFalseNoneFalse54427.5870
3574419129921NoneVOL I for the year 2023-24. Sl. No. 19 P.No. 112)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3233.323233.322.2FalseNoneNoneFalseNoneFalse7113.3040
3574420129921NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg194.07194.07151.2FalseNoneNoneFalseNoneFalse29343.3840
3574421129921NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1115.651115.6522.0FalseNoneNoneFalseNoneFalse24544.30
3574422129921NoneVOL II f 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos128.52128.5211.0FalseNoneNoneFalseNoneFalse1413.720
3574423129921NoneELE SR 23-24V-6 P-III It No 5.18.1 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SPEach435.75435.752.0FalseNoneNoneFalseNoneFalse871.50
3574424129921NoneELE SR 23-24V-6 P-III It No 5.42.1Pg.No 20 of 105Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. - 14SWGSq CM0.530.532500.0FalseNoneNoneFalseNoneFalse1325.00
3574425129921NoneV-II for the year 2023-24, I. No. 8.3.2 P.No. 41Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm349.65349.6536.4FalseNoneNoneFalseNoneFalse12727.260
3574426129921NoneVOL I 2023-24. I. No. 2.5.2 P.No. 16)Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.150.54FalseNoneNoneFalseNoneFalse3879.9810
3574427129921NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos253.83253.8322.0FalseNoneNoneFalseNoneFalse5584.260
3574428129921NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos108.17108.1766.0FalseNoneNoneFalseNoneFalse7139.220
3574429129921NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1246.081246.0837.52FalseNoneNoneFalseNoneFalse46752.92160
3574430129921NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.576.05FalseNoneNoneFalseNoneFalse104606.7750
3574431129921NoneELE SR 23-24V-6 P-III It No 5.18.4 Pg.No 17 of 105Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DPEach775.95775.952.0FalseNoneNoneFalseNoneFalse1551.90
3574432129921NoneELE SR 23-24V-6 P-III It No 6.3.1 Pg.No 30 of 105Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.Each3133.23133.29.0FalseNoneNoneFalseNoneFalse28198.80
3574433129921NoneV-5 for the year 2023-24. Sl. No. 18.3 P.No. 221)Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each2060.12060.11.0FalseNoneNoneFalseNoneFalse2060.10
3574434129921NoneVOL I 2023-24. Sl. No. 19 P.No. 112)Addendum I - Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3233.323233.320.54FalseNoneNoneFalseNoneFalse1745.99280
3574435129921NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos139.23139.2322.0FalseNoneNoneFalseNoneFalse3063.060
3574436129921NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos127.26127.2611.0FalseNoneNoneFalseNoneFalse1399.860
3574437129921NoneVOL II 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2738.212738.2125.85FalseNoneNoneFalseNoneFalse70782.72850
3574438129921NoneVOL II for the year 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.5413.23FalseNoneNoneFalseNoneFalse568397.8650
3574439129921NoneELE SR 23-24V-6 P-III It No 5.19.4 Pg.No 18 of 105Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door -12 Way SP &NEach1956.151956.152.0FalseNoneNoneFalseNoneFalse3912.30
3574440129921NoneELE SR 23-24V-6 P-III It No 8.2.2 Pg.No 36 of 105Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2PairMtr22.0522.0550.0FalseNoneNoneFalseNoneFalse1102.50
3574441129921NoneV - I for the year 2023-24, I. No. 2.11.a P.No.18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
3574442129921NoneVOL 2 for the year 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2021-22. I. No. 12.51 P.No. 104)Nos1088.141088.1410.0FalseNoneNoneFalseNoneFalse10881.40
3574443129921NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos251.34251.3422.0FalseNoneNoneFalseNoneFalse5529.480
3574444129921NoneVOL II 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.523.79FalseNoneNoneFalseNoneFalse32723.1450
3574445129921NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm147.41147.417.2FalseNoneNoneFalseNoneFalse1061.3520
3574446129921NoneVOL II for the year 2023-24. I. No. 6.34 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1159.21159.242.05FalseNoneNoneFalseNoneFalse48744.360
3574447129921NoneELE SR 23-24V-6 P-III It No 5.20.4 Pg.No 13 of 105Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. - 63 Amps 4 poleEach3210.93210.91.0FalseNoneNoneFalseNoneFalse3210.90
3574448129921NoneELE SR 23-24V-6 P-III It No 8.10.2 Pg.No 37 of 105Supplying & fixing of I/O socket with back box - Double I/oEach577.5577.53.0FalseNoneNoneFalseNoneFalse1732.50
3574449129921NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg195.99195.99907.2FalseNoneNoneFalseNoneFalse177802.1280
3574450129921NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos137.86137.8685.0FalseNoneNoneFalseNoneFalse11718.10
3574451129921NoneVOL II 2023-24. I. No. 6.32 P.No. 17)Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.5140.8FalseNoneNoneFalseNoneFalse193670.40
3574452129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.56136.63FalseNoneNoneFalseNoneFalse22893.72280
3574453129921NoneVOL II for the year 2023-24. I. No. 6.16 P.No. 15)Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.16 P.No. 15)Sqm99.7599.7542.05FalseNoneNoneFalseNoneFalse4194.48750
3574454129921NoneELE SR 23-24 V-6 P-III It No 8.11.2 Pg.No 37Supplying & Fixing of …mtrs Cat6 Patch Cable - 2mtrEach269.85269.853.0FalseNoneNoneFalseNoneFalse809.550
3574455129921NoneELE SR 23-24V-6 P-III It No 5.42.1Pg.No 20 of 105Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. - 14SWGSq CM0.520.529500.0FalseNoneNoneFalseNoneFalse4940.00
3574456129921NoneVOL I2023-24. I. No. 12.55.1 P.No. 104)Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. with both side prelam (PWD CSR VOL I for the year 2023-24. I. No. 12.55.1 P.No. 104)Sqm2509.142509.144.72FalseNoneNoneFalseNoneFalse11843.14080
3574457129921NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1258.421258.42308.8FalseNoneNoneFalseNoneFalse388600.0960
3574458129921NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm253.05253.05740.33FalseNoneNoneFalseNoneFalse187340.50650
3574459129921NoneVOL II 2023-24. I. No. 8.1.2 P.No. 41)Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm253.05253.05206.47FalseNoneNoneFalseNoneFalse52247.23350
3574460129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.5676.59FalseNoneNoneFalseNoneFalse12833.42040
3574461129921NoneELE SR 23-24V-6 P-III It No 5.44.1Pg.No 21 of 105Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. - 300mmx300mmx214mmEach4737.64737.61.0FalseNoneNoneFalseNoneFalse4737.60
3574462129921NoneELE SR 23-24V-6 P-III It No 8.12.3 Pg.No 37 of 105Supplying & Fixing of Patch panel for LAN cabling - 16 Port 10/100 patch panelEach3202.53202.51.0FalseNoneNoneFalseNoneFalse3202.50
3574463129921NoneVOL II 2023-24. I. No. 12.85 P.No. 109)Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.85 P.No. 109)Sqm6065.06065.02.52FalseNoneNoneFalseNoneFalse15283.80
3574464129921NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.95182.06FalseNoneNoneFalseNoneFalse53334.4770
3574465129921NoneVOL II 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm184.53184.53196.41FalseNoneNoneFalseNoneFalse36243.53730
3574466129921NoneVOL II for the year 2023-24. I. No. 8.2.2 P.No. 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.95788.79FalseNoneNoneFalseNoneFalse231076.03050
3574467129921NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2765.322765.32124.59FalseNoneNoneFalseNoneFalse344531.21880
3574468129921NoneELE SR 23-24V-6 P-III It No 6.3.1 Pg.No 30 of 105Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.Each3133.23133.241.0FalseNoneNoneFalseNoneFalse128461.20
3574469129921NoneELE SR 23-24V-6 P-III It No 8.13.1 Pg.No 37 of 105Supplying and fixing of MDF krone junction box with KRONE Module / Telephone - cable termination. - 10 Pairm362.25362.253.0FalseNoneNoneFalseNoneFalse1086.750
3574470129921NoneVOL 2 for the year 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1077.471077.4711.0FalseNoneNoneFalseNoneFalse11852.170
3574471129921NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.95199.59FalseNoneNoneFalseNoneFalse58469.89050
3574472129921NoneVOL II 2023-24. I. No. 8.2.2 P.No. 41)Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41)Sqm292.95292.9521.61FalseNoneNoneFalseNoneFalse6330.64950
3574473129921NoneVOL II 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm503.74503.743.6FalseNoneNoneFalseNoneFalse1813.4640
3574474129921NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2765.322765.3225.54FalseNoneNoneFalseNoneFalse70626.27280
3574475129921NoneELE SR 23-24V-6 P-III It No 11.3.2 Pg.No 43 of 105Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4'- 20/22 wEach724.5724.512.0FalseNoneNoneFalseNoneFalse8694.00
3574476129921NoneELE SR 23-24V-6 P-III It No 6.2.1 Pg.No 30 of 105Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each3117.453117.454.0FalseNoneNoneFalseNoneFalse12469.80
3574477129921NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne94869.1594869.151.74FalseNoneNoneFalseNoneFalse165072.3210
3574478129921NoneVOL II 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m351.28351.2839.6FalseNoneNoneFalseNoneFalse13910.6880
3574479129921NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg194.07194.07914.76FalseNoneNoneFalseNoneFalse177527.47320
3574480129921NoneVOL II 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm105.0105.0335.77FalseNoneNoneFalseNoneFalse35255.850
3574481129921NoneVOL II for the year 2023-24. I. No. 8.51 P.No. 50)Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm105.0105.01168.68FalseNoneNoneFalseNoneFalse122711.40
3574482129921NoneELE SR 23-24V-6 P-III It No 13.7.1 Pg.No 56 of 105Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / GirdersEach128.1128.112.0FalseNoneNoneFalseNoneFalse1537.20
3574483129921NoneELE SR 23-24V-6 P-III It No 8.2.2 Pg.No 36 of 105Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2PairMtr22.0522.05200.0FalseNoneNoneFalseNoneFalse4410.00
3574484129921NoneV-2 I.no 8.16.2 Pg.no 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m40.340.3129.3FalseNoneNoneFalseNoneFalse5210.790
3574485129921NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm147.79147.79164.16FalseNoneNoneFalseNoneFalse24261.20640
3574486129921NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum103755.75103755.750.81FalseNoneNoneFalseNoneFalse84042.15750
3574487129921NoneVOL II 2023-24. I. No. 12.13.1 P.No. 100)Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum103755.75103755.750.16FalseNoneNoneFalseNoneFalse16600.920
3574488129921NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1246.081246.08285.45FalseNoneNoneFalseNoneFalse355693.5360
3574489129921NoneELE SR 23-24V-6 P-III It No 13.10 Pg.No 56 of 105Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.559.0FalseNoneNoneFalseNoneFalse1615.950
3574490129921NoneELE SR 23-24V-6 P-III It No 8.10.2 Pg.No 37 of 105Supplying & fixing of I/O socket with back box - Double I/oEach577.5577.510.0FalseNoneNoneFalseNoneFalse5775.00
3574491129921NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3488.13488.15.04FalseNoneNoneFalseNoneFalse17580.0240
3574492129921NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm148.87148.8772.81FalseNoneNoneFalseNoneFalse10839.22470
3574493129921NoneVOL II 2023-24. I. No. 12.54 P.No. 104)Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.54 P.No. 104)Sqm333.9333.922.8FalseNoneNoneFalseNoneFalse7612.920
3574494129921NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2738.212738.21124.53FalseNoneNoneFalseNoneFalse340989.29130
3574495129921NoneELE 23-24V-6 P-III It No 8.11.2 Pg.No 37 of 105Supplying & Fixing of …mtrs Cat6 Patch Cable - 2mtrEach269.85269.8510.0FalseNoneNoneFalseNoneFalse2698.50
3574496129921NoneUNISR 23-24 Esc V-6 P-II Sno.197 IN.32.1 Pg.No 13Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 6 sqmmKm66576.366576.30.03FalseNoneNoneFalseNoneFalse1997.2890
3574497129921NoneVOL I 2023-24. I. No. 12.57.6 P.No. 105)Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3488.13488.122.47FalseNoneNoneFalseNoneFalse78377.6070
3574498129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm169.22169.22610.42FalseNoneNoneFalseNoneFalse103295.27240
3574499129921NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7070.77070.712.6FalseNoneNoneFalseNoneFalse89090.820
3574500129921NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2738.212738.2125.53FalseNoneNoneFalseNoneFalse69906.50130
3574501129921NoneELE SR 23-24V-6 P-III It No 8.12.3 Pg.No 37 of 105Supplying & Fixing of Patch panel for LAN cabling - 16 Port 10/100 patch panelEach3202.53202.51.0FalseNoneNoneFalseNoneFalse3202.50
3574502129921NoneUNISR 2023-24 EscV-6 P-II Sno. 167 I.N 20.05 Pg.52Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 2.5 sqmm to 25 sqmmKm1246.351246.350.03FalseNoneNoneFalseNoneFalse37.39050
3574503129921NoneVOL II 2023-24. I. No. 11.26.1 P.No. 84)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.26.1 P.No. 84)Kg147.8147.8622.0FalseNoneNoneFalseNoneFalse91931.60
3574504129921NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1104.61104.64.0FalseNoneNoneFalseNoneFalse4418.40
3574505129921NoneVOL II 2023-24. I. No. 12.90 P.No. 110)Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7070.77070.741.04FalseNoneNoneFalseNoneFalse290181.5280
3574506129921NoneVOL II for the year 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m347.84347.8439.6FalseNoneNoneFalseNoneFalse13774.4640
3574507129921NoneELE SR 23-24V-6 P-III It No 8.13.1 Pg.No 37 of 105Supplying and fixing of MDF krone junction box with KRONE Module / Telephone - cable termination. - 10 Pairm362.25362.255.0FalseNoneNoneFalseNoneFalse1811.250
3574508129921NoneUNISR 21-22 BSC V-6 P-II Sno. 201 I.N 29.02 Pg 08Earth work Excavation for cable trench of 0.5m to 0.75 mtr width and Depth upto 1 Mtrs including trial pits, depositing on bank upto a lead of 50 Mtrs , Supplying and Displaying necessary Danger Boards and Lighting , Using sight Rails and Sign Boards at every 100 Mtrs wherever necessary as directed. In soil (Ordinary) (1x70x0.50x0.75 = 26.25 CMT)Cum273.0273.07.5FalseNoneNoneFalseNoneFalse2047.50
3574509129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm169.22169.22406.66FalseNoneNoneFalseNoneFalse68815.00520
3574510129921NoneVOL II 2023-24. I. No. 12.60 P.No. 105)Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1104.61104.620.0FalseNoneNoneFalseNoneFalse22092.00
3574511129921NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos107.1107.112.0FalseNoneNoneFalseNoneFalse1285.20
3574512129921NoneVOL II for the year 2023-24. I. No. 9.11 P.No. 60)Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.11 P.No. 60)Sqm942.78942.7822.69FalseNoneNoneFalseNoneFalse21391.67820
3574513129921NoneELE SR 23-24V-6 P-III It No 11.3.2 Pg.No 43 of 105Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4'- 20/22 wEach724.5724.560.0FalseNoneNoneFalseNoneFalse43470.00
3574514129921NoneUNICSR 21-22 BES V-6 P-II Sno. 206 I.N 29.07 Pg.08Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. (1x70x0.50x0.75 = 26.25 CMT)Cum60.960.97.5FalseNoneNoneFalseNoneFalse456.750
3574515129921NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos126.0126.02.0FalseNoneNoneFalseNoneFalse252.00
3574516129921NoneVOL II 2023-24. I. No. 12.74.1 P.No. 107)Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos107.1107.154.0FalseNoneNoneFalseNoneFalse5783.40
3574517129921NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm186.34186.34591.54FalseNoneNoneFalseNoneFalse110227.56360
3574518129921NoneVOL II for the year 2023-24. I. No. 9.39 P.No. 65)Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.39 P.No. 65)Sqm1536.661536.6639.85FalseNoneNoneFalseNoneFalse61235.9010
3574519129921NoneELE SR 23-24V-6 P-III It No 11.8.2 Pg.No 46 of 105Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 40wattsEach4225.24225.21.0FalseNoneNoneFalseNoneFalse4225.20
3574520129921NoneELE SR 23-24V-6 P-III It No 12.57 Pg.No 55 of 105Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each3685.53685.51.0FalseNoneNoneFalseNoneFalse3685.50
3574521129921NoneVOL II 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm508.72508.7218.0FalseNoneNoneFalseNoneFalse9156.960
3574522129921NoneVOL II 2023-24. I. No. 12.58 P.No. 105)Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos126.0126.010.0FalseNoneNoneFalseNoneFalse1260.00
3574523129921NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos248.85248.854.0FalseNoneNoneFalseNoneFalse995.40
3574524129921NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm146.35146.35165.02FalseNoneNoneFalseNoneFalse24150.6770
3574525129921NoneELE SR 23-24V-6 P-III It No 13.7.1 Pg.No 56 of 105Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / GirdersEach128.1128.146.0FalseNoneNoneFalseNoneFalse5892.60
3574526129921NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne95808.4495808.4410.08FalseNoneNoneFalseNoneFalse965749.07520
3574527129921NoneVOL II 2023-24. I. No. 12.62 P.No. 105)Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos248.85248.8520.0FalseNoneNoneFalseNoneFalse4977.00
3574528129921NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos136.5136.54.0FalseNoneNoneFalseNoneFalse546.00
3574529129921NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm147.41147.4173.17FalseNoneNoneFalseNoneFalse10785.98970
3574530129921NoneELE SR 23-24V-6 P-III It No 13.5 Pg.No 56 of 105Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each170.1170.11.0FalseNoneNoneFalseNoneFalse170.10
3574531129921NoneV-2 I.NO 8.16.2 PG.NO 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m40.740.7636.51FalseNoneNoneFalseNoneFalse25905.9570
3574532129921NoneVOL 2 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1066.81066.82.0FalseNoneNoneFalseNoneFalse2133.60
3574533129921NoneVOL II 2023-24. I. No. 12.63 P.No. 105)Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos136.5136.520.0FalseNoneNoneFalseNoneFalse2730.00
3574534129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.56770.77FalseNoneNoneFalseNoneFalse129150.22120
3574535129921NoneELE SR 23-24V-6 P-III It No 13.10 Pg.No 56 of 105Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.5541.0FalseNoneNoneFalseNoneFalse7361.550
3574536129921NoneVOL I 2023-24. I. No. 12.55.1 P.No. 104)Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. with both side prelam (PWD CSR VOL I for the year 2023-24. I. No. 12.55.1 P.No. 104)Sqm2484.32484.36.3FalseNoneNoneFalseNoneFalse15651.090
3574537129921NoneVOL II 2023-24. I. No. 11.26.1 P.No. 84)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.26.1 P.No. 84)Kg146.35146.35622.0FalseNoneNoneFalseNoneFalse91029.70
3574538129921NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg192.15192.15264.6FalseNoneNoneFalseNoneFalse50842.890
3574539129921NoneELE SR 23-24V-6 P-III It No 13.14 Pg.No 57 of 105Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each516.6516.64.0FalseNoneNoneFalseNoneFalse2066.40
3574540129921NoneVOL II 2023-24. I. No. 12.85 P.No. 109)Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.85 P.No. 109)Sqm6004.956004.952.52FalseNoneNoneFalseNoneFalse15132.4740
3574541129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm167.56167.56433.26FalseNoneNoneFalseNoneFalse72597.04560
3574542129921NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1233.751233.7575.04FalseNoneNoneFalseNoneFalse92580.60
3574543129921NoneUNI SR 23-24 Escoms V-6 P-II It No 32.04 P 13Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 16 sqmmKm92838.992838.90.08FalseNoneNoneFalseNoneFalse7427.1120
3574544129921NoneVOL 2 for the year 2021-22. I. No. 12.51 P.No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1066.81066.810.0FalseNoneNoneFalseNoneFalse10668.00
3574545129921NoneVOL II 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.141.9FalseNoneNoneFalseNoneFalse113595.090
3574546129921NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm184.53184.53628.66FalseNoneNoneFalseNoneFalse116006.62980
3574547129921NoneUNISR 2023-24 Esc V-6 P-II Sl.197 I.no 32.01 Pg 13Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 6 sqmmKm66576.366576.30.02FalseNoneNoneFalseNoneFalse1331.5260
3574548129921NoneVOL II 2023-24. I. No. 11.34B P.No. 86)Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg192.15192.15922.32FalseNoneNoneFalseNoneFalse177223.7880
3574549129921NoneVOL II 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.127.13FalseNoneNoneFalseNoneFalse73552.1430
3574550129921NoneVOL II for the year 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm503.74503.7418.0FalseNoneNoneFalseNoneFalse9067.320
3574551129921NoneUNISR 23-24 Esc V-6 P-II Sno. 167 I.no 20.05 Pg 52Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 2.5 sqmm to 25 sqmmKm1246.351246.350.1FalseNoneNoneFalseNoneFalse124.6350
3574552129921NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne94869.1594869.1510.04FalseNoneNoneFalseNoneFalse952486.2660
3574553129921NoneVOL II 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m344.4344.454.6FalseNoneNoneFalseNoneFalse18804.240
3574554129921NoneVOL II for the year 2023-24. I. No. 11.3 P.No. 77)Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.3 P.No. 77)Sqm8689.88689.88.37FalseNoneNoneFalseNoneFalse72733.6260
3574555129921NoneUNISR 2021-22 Bsc V-6 P-II Sno. 201 I.no 29.02-08Earth work Excavation for cable trench of 0.5m to 0.75 mtr width and Depth upto 1 Mtrs including trial pits, depositing on bank upto a lead of 50 Mtrs , Supplying and Displaying necessary Danger Boards and Lighting , Using sight Rails and Sign Boards at every 100 Mtrs wherever necessary as directed. In soil (Ordinary) (1x70x0.50x0.75 = 26.25 CMT)Cum273.0273.026.25FalseNoneNoneFalseNoneFalse7166.250
3574556129921NoneV-2 I.NO 8.16.2 PG. 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m40.340.3636.51FalseNoneNoneFalseNoneFalse25651.3530
3574557129921NoneVOL II 2023-24. I. No. 11.6.1 P.No. 78)Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.6.1 P.No. 78)Sqm2764.652764.658.37FalseNoneNoneFalseNoneFalse23140.12050
3574558129921NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm144.9144.912.1FalseNoneNoneFalseNoneFalse1753.290
3574559129921NoneUNISR 21-22 BSC V-6 P-II Sno.206 I.NO 29.07 Pg 08Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. (1x70x0.50x0.75 = 26.25 CMT)Cum60.960.926.25FalseNoneNoneFalseNoneFalse1598.6250
3574560129921NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm145.95145.9520.06FalseNoneNoneFalseNoneFalse2927.7570
3574561129921NoneVOL II 2023-24. I. No. 9.17.2 P.No. 61)Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.17.2 P.No. 61)Sqm1233.751233.75310.02FalseNoneNoneFalseNoneFalse382487.1750
3574562129921NoneELE SR 23-24V-6 P-III It No 5.31 Pg.No 19 of 105Supplying and fixing Trivector Meter suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.Each4609.54609.51.0FalseNoneNoneFalseNoneFalse4609.50
3574563129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9206.47FalseNoneNoneFalseNoneFalse34253.3730
3574564129921NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.1120.87FalseNoneNoneFalseNoneFalse327690.6570
3574565129921NoneELE SR 23-24V-6 P-III It No 12.57 Pg.No 55 of 105Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each3685.53685.54.0FalseNoneNoneFalseNoneFalse14742.00
3574566129921NoneVOL II 2023-24. I. No. 11.28 P.No. 85)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.28 P.No. 85)Kg144.9144.9156.76FalseNoneNoneFalseNoneFalse22714.5240
3574567129921NoneVOL II for the year 2023-24. I. No. 9.32 P.No. 64)Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.148.84FalseNoneNoneFalseNoneFalse132410.1240
3574568129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9129.3FalseNoneNoneFalseNoneFalse21450.870
3574569129921NoneVOL II for the year 2023-24. I. No. 10.2 P.No. 69)Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m344.4344.487.48FalseNoneNoneFalseNoneFalse30128.1120
3574570129921NoneVOL II 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm182.7182.7182.06FalseNoneNoneFalseNoneFalse33262.3620
3574571129921NoneVOL II for the year 2023-24. I. No. 9.11 P.No. 60)Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.11 P.No. 60)Sqm933.45933.4525.25FalseNoneNoneFalseNoneFalse23569.61250
3574572129921NoneVOL II 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm498.75498.757.2FalseNoneNoneFalseNoneFalse3591.00
3574573129921NoneVOL II for the year 2023-24. I. No. 9.39 P.No. 65)Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.39 P.No. 65)Sqm1521.451521.4553.08FalseNoneNoneFalseNoneFalse80758.5660
3574574129921NoneVOL II 2023-24. I. No. 8.33.2 P.No. 46)Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.2 P.No. 46)Sqm144.9144.957.45FalseNoneNoneFalseNoneFalse8324.5050
3574575129921NoneVOL II 2023-24. I. No. 8.49 P.No. 49)Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.49 P.No. 49)cm4.24.21000.0FalseNoneNoneFalseNoneFalse4200.00
3574576129921NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne93929.8593929.854.48FalseNoneNoneFalseNoneFalse420805.7280
3574577129921NoneVOL II 2023-24. I. No. 8.33.3 P.No. 47)Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm145.95145.9599.09FalseNoneNoneFalseNoneFalse14462.18550
3574578129921NoneV-2 I.no 8.16.2 Pg.no 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m39.939.9240.86FalseNoneNoneFalseNoneFalse9610.3140
3574579129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9740.33FalseNoneNoneFalseNoneFalse122820.7470
3574580129921NoneVOL II 2023-24. I. No. 11.26.1 P.No. 84)Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.26.1 P.No. 84)Kg144.9144.9496.18FalseNoneNoneFalseNoneFalse71896.4820
3574581129921NoneVOL II 2023-24. I. No. 8.33.1 P.No. 46)Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9428.35FalseNoneNoneFalseNoneFalse71063.2650
3574582129921NoneVOL II for the year 2023-24. I. No. 8.30 P.No. 46)Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.30 P.No. 46)Sqm182.7182.7788.79FalseNoneNoneFalseNoneFalse144111.9330
3574583129921NoneVOL II for the year 2023-24. I. No. 8.84 P.No. 55)Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
3574584129921NoneVOL II for the year 2023-24. I. No. 8.49 P.No. 49)Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.49 P.No. 49)cm4.24.23300.0FalseNoneNoneFalseNoneFalse13860.00
3574585129921NoneVOL I 2023-24. I. No. 2.11.a P.No. 18)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne93929.8593929.8520.34FalseNoneNoneFalseNoneFalse1910533.1490
3574586129921NoneV-2 8.16.2 PG.NO 43Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (PWD SR for Buildings V-2 I no 8.16.2 P no 43) m39.939.9636.51FalseNoneNoneFalseNoneFalse25396.7490
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17216278580000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17216278580000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17216278580000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of kppp portal due to internet connectivity issues and technical glitches at bidders end.None
17216278580000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17216278580000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17216278580000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27.7.2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund.None
17216278580000NoneNoneELIGIBILITYThe Item Rate quoted shall include the Royalty Charges on construction materials and other taxes as per prevailing Government Orders.None
17216278580000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17216278580000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate/Certificates shall be produced at the time of opening of technical Bids for physical verification.None
17216278580000NoneNoneELIGIBILITYThe Employer reserves the right to Reject any or all Tenders without assigning any reason.None
17216278580000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 - Qualification of the Tenderer in Section 2 : Instructions to Tenderers (ITT), will only be considered for evaluation.None
17216278580000NoneNoneELIGIBILITYBidders are advised to note that, 18% GST will be added to the contract amount. The Increse in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17216278580000NoneNoneELIGIBILITYThe bidder should mention the UDIN No on the turnover certificate, failing which bid is rejected.None
17216278580000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17216278580000NoneNoneELIGIBILITYThe work should be completed in 11 (Eleven) Months ( including monsoon).None
17216278580000NoneNoneELIGIBILITYThe KPWD Code, KTTP Act/Rules ,Delegation of Powers and other Government Orders issued by the Government from time to time will apply.None
17216278580000NoneNoneELIGIBILITYAll the specifications in the commercial bid format please be read as with all leads and lifts etc., complete as per specification and as directed by the engineer-in-charge.None
17216278580000NoneNoneELIGIBILITYDefect liability period is One (1) year from the date of actual completion of the work.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNone3.2(b). To qualify for award of this contract, each Tenderer in his name should have in the last five years i.e. (between 2019-20 to 2023-24) , (b) Satisfactory completion as a prime contractor for at least one similar nature of work to an extent of 50% of the cost of the work. Rs. 129.20 Lakhs.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNone3.2 (a) To qualify for award of this contract, each Tenderer in his name should have in the last five years i.e. (between 2019-20 to 2023-24) (a) Achieved in at least two financial years a minimum financial turnover (In all classes of Civil Engineering Construction works only) (not less than 2 times the estimated annual payment under this contract) of Rs 516.79 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNone3.3 (b). Liquid assets and or availability of credit facilities of not less than Rs. 70.47 Lakhs. (Credit lines / Letter of credit / Certificates from Banks) for meeting the fund requirement etc. (usually the equivalent of the estimate cash flow for three months in peak construction period. ( NEW FORMAT ENCLOSED AS PER GOVT CIRCULAR NO.FDCAM/16/2022(K-2) DATED:-22-08-2022.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNone3.2. To qualify for award of this contract, each Tenderer in his name should have in the last five years i.e. (between 2019-20 to 2023-24. To qualify for award of this contract, (c) Executed in any one year (for a continuous period of 12 months), the minimum quantities of work: (usually 80% of annual rate or requirement) (a) Earthwork excavation /Subgrade/Embankment : 1910.00 cum (b) PCC / RCC : 592.00 Cum (c) Steel : 40.00 Ton. (d) Solid block masonry : 1573.00 Sqm (e) Cement plastering : 4613.00 Sqm (f) Flooring : 1318.00 SqmOthersQuantity wise work done certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Quantity wise work done certificate
NoneNoneNoneNoneList of existing commitments and ongoing worksOthersexisting commitments and ongoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedOthersList of works for which tenders already submitted
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
NoneNoneNoneNoneBanker Details for referenceOthersBanker Details for reference
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedOtherskey technical and management personnel
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- key technical and management personnel
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
Similar nature of single work done certificateTrueTechnical Bid
Quantity wise workdone certificateTrueTechnical Bid
Line of credit / Bankers certificateTrueTechnical Bid
Assesed tender capacity / Bid capacityTrueTechnical Bid
Any other relevant documentsTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721628422000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executive Engineer, PWD division, Raichur.
streetNone
cityRAICHUR
stateKarnataka
pin584101
tenderRecallDTONone