createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721386341540
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd25000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose29-07-2024 17:30:00
tenderQueryClose24-07-2024 17:00:00
technicalBidOpenNone
publishedDate22-07-2024 13:42:37
publishedByPostKKRTC_EE_HOFF_KLB
publishedByUserKPE11172 - CHANNAN BORAIAH
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonChannana Boraiah
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber8472220663
mobileNumber7760992033
tenderSupplierListNone
tenderSchedule
createdTs1721386341575
version8
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/BD/WORK_INDENT60
titleConstruction of modern toilet block bus station at Madhvar.
descriptionConstruction of modern toilet block bus station at Madhvar.
categoryWORKS
categoryTextWorks
ecv1000000.00
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5935
locationNameKalyana Karnataka Road Transport Corporation Head Office Kalburgi
provisionalAmount1000000.0
groupOverheadTotal4391.3
fileNumberKKRTC/EEG/KLB/DB/T/270/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17213863420000NoneNoneBuildingsConstruction of modern toilet block bus station at Madhvar.995608.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3554450128595Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) Depth exceeding 1.5 m, but not exceeding 3 m.In all kinds of soils Depth upto 3 mCum126.37126.3746.85FalseNoneNoneFalseNoneFalse5920.43450
3554451128595Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1.4.8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum7017.697017.695.55FalseNoneNoneFalseNoneFalse38948.17950
3554452128595Nonecode03Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP- Vol-I (7/1.9)Cum329.57329.5723.42FalseNoneNoneFalseNoneFalse7718.52940
3554453128595Nonecode04KSRB 2.3 . Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP- Vol-I (7/1.10) SRP A-39/36 ( without Royalty )Cum520.38520.3814.24FalseNoneNoneFalseNoneFalse7410.21120
3554454128595Nonecode05Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1.2.4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum7934.557934.550.74FalseNoneNoneFalseNoneFalse5871.5670
3554455128595Nonecode06Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated)Cum8478.328478.324.41FalseNoneNoneFalseNoneFalse37389.39120
3554456128595Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Column) ( Corrigendum-3)Cum14413.4114413.413.62FalseNoneNoneFalseNoneFalse52176.54420
3554457128595Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/8 (Plinth beams of Building as per corrigendum-3)Cum12717.7112717.712.17FalseNoneNoneFalseNoneFalse27597.43070
3554458128595Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/12 (Beam & Lintal of Building) ( Corrigendum-3)Cum13565.5613565.563.04FalseNoneNoneFalseNoneFalse41239.30240
3554459128595Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/13 (Roof (Straight & Arched) ( Corrigendum-3)Cum12717.7112717.713.23FalseNoneNoneFalseNoneFalse41078.20330
3554460128595Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 116/20 (Chejjas,canopy & other Arch Projection of minor section)Cum12293.7912293.790.2FalseNoneNoneFalseNoneFalse2458.7580
3554461128595Nonecode12Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-II (84/11.32)Kg110.82110.821444.12FalseNoneNoneFalseNoneFalse160037.37840
3554462128595Nonecode13Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (106/12.57.5) 35 mm thick one side teak and one side commercialSqm5615.145615.143.78FalseNoneNoneFalseNoneFalse21225.22920
3554463128595Nonecode14Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12)Cum153886.27153886.270.11FalseNoneNoneFalseNoneFalse16927.48970
3554464128595Nonecode15Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (105/12.54)Rmtr394.0394.011.4FalseNoneNoneFalseNoneFalse4491.60
3554465128595Nonecode16Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.SRP- Vol-II (106/12.55.2) with one side prelam.Sqm2894.32894.33.15FalseNoneNoneFalseNoneFalse9117.0450
3554466128595Nonecode17Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/34A)Kg208.15208.1557.96FalseNoneNoneFalseNoneFalse12064.3740
3554467128595Nonecode18Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1.6 (1 cement . 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8)Cum9873.599873.5916.8FalseNoneNoneFalseNoneFalse165876.3120
3554468128595Nonecode19Providing 15 mm cement plaster on the rough side of single or half brick wall of mix .1.4 (1 cement. 4 Fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1)Sqm365.5365.5123.2FalseNoneNoneFalseNoneFalse45029.60
3554469128595Nonecode20Providing 12 mm cement plaster with cement mortar 1.4 (1 cement.4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.2)Sqm315.94315.9455.5FalseNoneNoneFalseNoneFalse17534.670
3554470128595Nonecode21Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1.6, 20 mm thick, and joints finished with cement mortar 1.3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30)Sqm6601.396601.392.25FalseNoneNoneFalseNoneFalse14853.12750
3554471128595Nonecode22Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (69/10.2)Rmtr406.39406.394.5FalseNoneNoneFalseNoneFalse1828.7550
3554472128595Nonecode23Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1.6 bed concrete 150mm thick with 1.3.6 with plastering 12 mm thick with CM 1.4.CC 1.2.4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 16.9/191Each5936.045936.044.0FalseNoneNoneFalseNoneFalse23744.160
3554473128595Nonecode24Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note. Upto 110mm dia Coil shall be used. SRP- Vol-V 94/9.1.4Rmtr581.09581.0930.0FalseNoneNoneFalseNoneFalse17432.70
3554474128595Nonecode25Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651.1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1.1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 184/2.2/T040BRmtr719.85719.8510.0FalseNoneNoneFalseNoneFalse7198.50
3554475128595Nonecode26Providing and placing on terrace ( at all floor levels ) polyethylene water storage tanks,IS . 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP- Vol-II (12/13.34)Ltr11.1511.151000.0FalseNoneNoneFalseNoneFalse11150.00
3554476128595Nonecode27Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (11/13.33.6) 40 mmMtr591.0591.040.0FalseNoneNoneFalseNoneFalse23640.00
3554477128595Nonecode2825 mmMtr366.74366.7430.0FalseNoneNoneFalseNoneFalse11002.20
3554478128595Nonecode2920 mmMtr268.86268.8625.0FalseNoneNoneFalseNoneFalse6721.50
3554479128595Nonecode3015 mmMtr205.67205.6720.0FalseNoneNoneFalseNoneFalse4113.40
3554480128595Nonecode31White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (125/14.7.7)Nos2600.662600.662.0FalseNoneNoneFalseNoneFalse5201.320
3554481128595Nonecode32Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS . 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required SRP- Vol-II (123/14.1.1)White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.Nos6051.276051.272.0FalseNoneNoneFalseNoneFalse12102.540
3554482128595Nonecode33Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and makinggood the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern SRP- Vol-II (123/14.4.1)Each5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3554483128595Nonecode34Providing and fixing white vitreous china water closet squatting pan (Indian type) Long pattern W.C. pan of size 580 mm SRP- Vol-II (126/14.13.1)Each1769.291769.293.0FalseNoneNoneFalseNoneFalse5307.870
3554484128595Nonecode35Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing . SRP- Vol-II (128/14.32.3)Unit1320.771320.772.0FalseNoneNoneFalseNoneFalse2641.540
3554485128595Nonecode36Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1.2.4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2Each336.3336.34.0FalseNoneNoneFalseNoneFalse1345.20
3554486128595Nonecode37Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP- Vol-II (117/13.5.1)Nos366.74366.746.0FalseNoneNoneFalseNoneFalse2200.440
3554487128595Nonecode38Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3)Nos869.77869.773.0FalseNoneNoneFalseNoneFalse2609.310
3554488128595Nonecode39Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP- Vol-II (117/13.3.1)Nos370.46370.465.0FalseNoneNoneFalseNoneFalse1852.30
3554489128595Nonecode40Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS . 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1.4 (1 Cement . 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11)Sqm1101.471101.4711.04FalseNoneNoneFalseNoneFalse12160.22880
3554490128595Nonecode41Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1.3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38)Sqm1724.681724.6811.85FalseNoneNoneFalseNoneFalse20437.4580
3554491128595Nonecode42Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1.6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.SRP- Vol-II (64/9.34)Sqm1914.251914.256.48FalseNoneNoneFalseNoneFalse12404.340
3554492128595Nonecode43SRP.1.2 Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe 25 mm dia 2 .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick 1.2.2Mtr96.6496.6460.0FalseNoneNoneFalseNoneFalse5798.40
3554493128595Nonecode44SRP. 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr97.8897.8830.0FalseNoneNoneFalseNoneFalse2936.40
3554494128595Nonecode451.1.2 Open Conduit System.Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr100.35100.3550.0FalseNoneNoneFalseNoneFalse5017.50
3554495128595Nonecode46SRP.2.3.Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694.confirming to latest amendments. 1.5 sqmm 2.3.2Mtr32.2132.21200.45FalseNoneNoneFalseNoneFalse6456.49450
3554496128595Nonecode47Do- 2.5 sqmm (P6/2.3.3)Mtr52.0352.03120.0FalseNoneNoneFalseNoneFalse6243.60
3554497128595Nonecode48Do- 4 sqmm (P6/2.3.4)Mtr78.0578.0540.0FalseNoneNoneFalseNoneFalse3122.00
3554498128595Nonecode49SRP.2.2.1.Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694. and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNo333.29333.293.0FalseNoneNoneFalseNoneFalse999.870
3554499128595Nonecode50Do- Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2)No469.58469.584.0FalseNoneNoneFalseNoneFalse1878.320
3554500128595Nonecode51Do- Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3)No687.64687.646.0FalseNoneNoneFalseNoneFalse4125.840
3554501128595Nonecode52Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-3Way 3.4.1No170.98170.982.0FalseNoneNoneFalseNoneFalse341.960
3554502128595Nonecode53Do- 4-5way (P15/3.4.3)No219.3219.31.0FalseNoneNoneFalseNoneFalse219.30
3554503128595Nonecode54Do-6 way (P15/3.4.4)No272.58272.581.0FalseNoneNoneFalseNoneFalse272.580
3554504128595Nonecode55Do-10-12 way (P15/3.4.6)No395.24395.242.0FalseNoneNoneFalseNoneFalse790.480
3554505128595Nonecode56Do-18 way (P15/3.4.8)No501.79501.791.0FalseNoneNoneFalseNoneFalse501.790
3554506128595Nonecode57Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module 3.5.1No169.74169.742.0FalseNoneNoneFalseNoneFalse339.480
3554507128595Nonecode58Do- 4 mod (P16/3.5.3)No216.82216.821.0FalseNoneNoneFalseNoneFalse216.820
3554508128595Nonecode59Do- 6 Module (P16/3.5.4)No289.92289.921.0FalseNoneNoneFalseNoneFalse289.920
3554509128595Nonecode60Do-10-12 Module (P16/3.5.6)No426.21426.212.0FalseNoneNoneFalseNoneFalse852.420
3554510128595Nonecode61Do-18 Module (P16/3.5.8)No566.22566.221.0FalseNoneNoneFalseNoneFalse566.220
3554511128595Nonecode62Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1No126.37126.3712.0FalseNoneNoneFalseNoneFalse1516.440
3554512128595Nonecode63Do- 6Amps 3 way socket (P16/3.6.3)No211.86211.863.0FalseNoneNoneFalseNoneFalse635.580
3554513128595Nonecode64Do- modular stepped fan regulator (P16/3.6.4)No442.32442.321.0FalseNoneNoneFalseNoneFalse442.320
3554514128595Nonecode65Do- 16Amps one way switch (P16/3.6.7)No223.02223.021.0FalseNoneNoneFalseNoneFalse223.020
3554515128595Nonecode66Do- 6/16 Amps universal socket (P16/3.6.10)No292.4292.41.0FalseNoneNoneFalseNoneFalse292.40
3554516128595Nonecode67Supplying and fixing Fan box with round hook (P3/1.13)No144.96144.961.0FalseNoneNoneFalseNoneFalse144.960
3554517128595Nonecode68Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2Mtr27.2527.2512.0FalseNoneNoneFalseNoneFalse327.00
3554518128595Nonecode69Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI more than 80. Power Input. 220-240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fighting 1 x4- 20/22 wNo854.91854.918.0FalseNoneNoneFalseNoneFalse6839.280
3554519128595Nonecode70Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SPNo514.18514.184.0FalseNoneNoneFalseNoneFalse2056.720
3554520128595Nonecode71Do- 6-32 Amps DP. (5.18.2)No915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3554521128595Nonecode7211.2.1.Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRImore than 70percentage. efficacy more than80 lumen per watt, lifemore than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Each771.89771.896.0FalseNoneNoneFalseNoneFalse4631.340
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17213863430000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17213863430000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17213863430000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17213863430000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17213863430000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17213863430000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17213863430000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17213863430000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17213863430000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17213863430000NoneNoneELIGIBILITYBanker DetailsNone
17213863600000NoneNoneELIGIBILITYShould be a valid Class-III & above Contractor registered in Karnataka CPWD/MES and KPWD. Upload Registration Certificate for the block period 2020-25.None
17213863760000NoneNoneELIGIBILITYShould have successfully completed at least one work of similar nature of work, costing not less than Rs. 5.00 lakhs (Rs. Five Lakhs) i.e., from 01/04/2019 onwards for any of the Govt./ Public Sector Corporate undertakings. Certificate of completion issued by an officer not below the rank of Executive Engineer, in case of Govt., / Public Sectors under takings.None
17213863940000NoneNoneELIGIBILITYShould have achieved a Annual Financial Turnover of Rs. 10.00 Lakhs (Rs. Ten Lakhs) pertaining to civil works for any of 2 (two) financial years from last preceding Five years i.e (2019-20, 2020-21, 2021-22 , 2022-23 & 2023-24).Upload a copy of audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant along with Income Tax Return Acknowledgement for respective Years.None
17213864100000NoneNoneELIGIBILITYPerformance security for unbalance Rates Within 20 Days of receipt of letter of acceptance, the successful bidder shall deliver to employer an amount equal to difference of sanctioned and approved bid amount in the form of D.D/ Banker cheque / Bank Guaranty in favour of Executive Engineer KKRTC CE Div Kalaburagi. The same will be refunded after completion of work. (Attach self declaration certificate)None
17213864240000NoneNoneELIGIBILITYEstimated Rates inclusive of all applicable taxes including GST.None
17213864340000NoneNoneELIGIBILITYThe bidder shall quote their rates inclusive of all applicable taxes and inclusive of GST.None
17213864550000NoneNoneELIGIBILITYGST will not be paid separately. It is added in the individual items rates.None
17213865030000NoneNoneELIGIBILITYRemaining all terms and conditions as per tender Notification.None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Should be a valid Class-III & above Contractor registered in Karnataka CPWD/MES and KPWD. Upload Registration Certificate for the block period 2020-25.TrueTechnical Bid
Should have successfully completed at least one work of similar nature of work, costing not less than Rs. 5.00 lakhs Rs. Five Lakhs i.e., from 01/04/2019 onwards for any of the Govt./ Public Sector Corporate undertakings. Certificate of completion issued by an officer not below the rank of Executive Engineer, in case of Govt., / Public Sectors under takings.TrueTechnical Bid
Should have achieved a Annual Financial Turnover of Rs. 10.00 Lakhs Rs. Ten Lakhs pertaining to civil works for any of 2 two financial years from last preceding Five years i.e 2019-20, 2020-21, 2021-22 , 2022-23 & 2023-24. Upload a copy of audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant along with Income Tax Return Acknowledgement for respective Years.TrueTechnical Bid
Performance security for unbalance Rates Within 20 Days of receipt of letter of acceptance, the successful bidder shall deliver to employer an amount equal to difference of sanctioned and approved bid amount in the form of D.D/ Banker cheque / Bank Guaranty in favour of Executive Engineer KKRTC CE Div Kalaburagi. The same will be refunded after completion of work. Attach self declaration certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone