3589658 | 130582 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Manual Means
a) In area of light jungle | Sqm | 1256.63 | 1256.63 | 6.0 | False | None | None | False | None | False | 7539.78 | 0 |
3589659 | 130582 | None | code02 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m | Sqm | 271.04 | 271.04 | 663.0 | False | None | None | False | None | False | 179699.52 | 0 |
3589660 | 130582 | None | code03 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 m | Sqm | 290.08 | 290.08 | 115.0 | False | None | None | False | None | False | 33359.2 | 0 |
3589661 | 130582 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Sqm | 297.92 | 297.92 | 541.0 | False | None | None | False | None | False | 161174.72 | 0 |
3589662 | 130582 | None | code05 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Sqm | 530.88 | 530.88 | 139.0 | False | None | None | False | None | False | 73792.32 | 0 |
3589663 | 130582 | None | code06 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 132.16 | 132.16 | 461.0 | False | None | None | False | None | False | 60925.76 | 0 |
3589664 | 130582 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Sqm | 6343.68 | 6343.68 | 108.0 | False | None | None | False | None | False | 685117.44 | 0 |
3589665 | 130582 | None | code08 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Ground Floor | Sqm | 6963.04 | 6963.04 | 20.0 | False | None | None | False | None | False | 139260.8 | 0 |
3589666 | 130582 | None | code09 | First floor | Sqm | 7032.67 | 7032.67 | 1.5 | False | None | None | False | None | False | 10549.005 | 0 |
3589667 | 130582 | None | code10 | Terrace floor | Sqm | 7171.93 | 7171.93 | 10.0 | False | None | None | False | None | False | 71719.3 | 0 |
3589668 | 130582 | None | code11 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts,cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lift walls | Sqm | 7257.6 | 7257.6 | 2.28 | False | None | None | False | None | False | 16547.328 | 0 |
3589669 | 130582 | None | code12 | Retaining Wall | Sqm | 725.76 | 725.76 | 2.28 | False | None | None | False | None | False | 1654.7328 | 0 |
3589670 | 130582 | None | code13 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 7096.32 | 7096.32 | 143.0 | False | None | None | False | None | False | 1014773.76 | 0 |
3589671 | 130582 | None | code14 | Shuttering Work for Isolated Footing | Sqm | 567.7 | 567.7 | 75.291 | False | None | None | False | None | False | 42742.7007 | 0 |
3589672 | 130582 | None | code15 | Shuttering Work for Combined Footing | Sqm | 212.88 | 212.88 | 12.3975 | False | None | None | False | None | False | 2639.1798 | 0 |
3589673 | 130582 | None | code16 | Shuttering Work for Pedestals | Sqm | 4967.42 | 4967.42 | 12.23 | False | None | None | False | None | False | 60751.5466 | 0 |
3589674 | 130582 | None | code17 | Shuttering Work for Column Upto Plinth Beam | Sqm | 4967.42 | 4967.42 | 10.87 | False | None | None | False | None | False | 53995.8554 | 0 |
3589675 | 130582 | None | code18 | Shuttering Work for Plinth Beam | Sqm | 3548.16 | 3548.16 | 31.91 | False | None | None | False | None | False | 113221.7856 | 0 |
3589676 | 130582 | None | code19 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 7664.16 | 7664.16 | 121.0 | False | None | None | False | None | False | 927363.36 | 0 |
3589677 | 130582 | None | code20 | First floor | Sqm | 7740.8 | 7740.8 | 121.0 | False | None | None | False | None | False | 936636.8 | 0 |
3589678 | 130582 | None | code21 | Terrace floor head room | Sqm | 7817.44 | 7817.44 | 3.0 | False | None | None | False | None | False | 23452.32 | 0 |
3589679 | 130582 | None | code22 | Columns Ground Floor | Sqm | 5364.91 | 5364.91 | 16.94 | False | None | None | False | None | False | 90881.5754 | 0 |
3589680 | 130582 | None | code23 | Columns First Floor | Sqm | 5418.56 | 5418.56 | 16.94 | False | None | None | False | None | False | 91790.4064 | 0 |
3589681 | 130582 | None | code24 | Columns Terrace Floor | Sqm | 5472.21 | 5472.21 | 2.1672 | False | None | None | False | None | False | 11859.373512 | 0 |
3589682 | 130582 | None | code25 | Shuttering Roof Beam Ground Floor | Sqm | 4598.49 | 4598.49 | 34.66 | False | None | None | False | None | False | 159383.6634 | 0 |
3589683 | 130582 | None | code26 | Shuttering Roof Beam First Floor | Sqm | 4644.48 | 4644.48 | 34.66 | False | None | None | False | None | False | 160977.6768 | 0 |
3589684 | 130582 | None | code27 | Shuttering Roof Slab Ground Floor | Sqm | 3832.08 | 3832.08 | 66.55 | False | None | None | False | None | False | 255024.924 | 0 |
3589685 | 130582 | None | code28 | Shuttering Roof Slab First Floor | Sqm | 3870.4 | 3870.4 | 66.58 | False | None | None | False | None | False | 257691.232 | 0 |
3589686 | 130582 | None | code29 | Shuttering Work Staircase Ground Floor | Sqm | 3448.87 | 3448.87 | 2.8 | False | None | None | False | None | False | 9656.836 | 0 |
3589687 | 130582 | None | code30 | Shuttering Work Staircase First Floor | Sqm | 3483.36 | 3483.36 | 2.8 | False | None | None | False | None | False | 9753.408 | 0 |
3589688 | 130582 | None | code31 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor | Sqm | 7425.6 | 7425.6 | 8.0 | False | None | None | False | None | False | 59404.8 | 0 |
3589689 | 130582 | None | code32 | First Floor | Sqm | 7499.85 | 7499.85 | 8.0 | False | None | None | False | None | False | 59998.8 | 0 |
3589690 | 130582 | None | code33 | Terrace floor | Sqm | 7574.11 | 7574.11 | 1.5 | False | None | None | False | None | False | 11361.165 | 0 |
3589691 | 130582 | None | code34 | Shuttering Work Lintel Beam Ground Floor | Sqm | 4455.36 | 4455.36 | 3.87 | False | None | None | False | None | False | 17242.2432 | 0 |
3589692 | 130582 | None | code35 | Shuttering Work Lintel Beam First Floor | Sqm | 4499.91 | 4499.91 | 3.87 | False | None | None | False | None | False | 17414.6517 | 0 |
3589693 | 130582 | None | code36 | Shuttering Work Lintel Beam Terrace Floor | Sqm | 4544.46 | 4544.46 | 1.5 | False | None | None | False | None | False | 6816.69 | 0 |
3589694 | 130582 | None | code37 | Shuttering Work Chajja Ground Floor | Sqm | 3341.52 | 3341.52 | 8.0 | False | None | None | False | None | False | 26732.16 | 0 |
3589695 | 130582 | None | code38 | Shuttering Work Chajja First Floor | Sqm | 3374.93 | 3374.93 | 8.0 | False | None | None | False | None | False | 26999.44 | 0 |
3589696 | 130582 | None | code39 | Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately)
Stilt Floor | Sqm | 100191.84 | 100191.84 | 29.5 | False | None | None | False | None | False | 2955659.28 | 0 |
3589697 | 130582 | None | code40 | First floor | Sqm | 101193.75 | 101193.75 | 15.5 | False | None | None | False | None | False | 1568503.125 | 0 |
3589698 | 130582 | None | code41 | TERRACE AND HEADROOM | Sqm | 102195.67 | 102195.67 | 2.0 | False | None | None | False | None | False | 204391.34 | 0 |
3589699 | 130582 | None | code42 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Sqm | 7155.68 | 7155.68 | 63.0 | False | None | None | False | None | False | 450807.84 | 0 |
3589700 | 130582 | None | code43 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 285.6 | 285.6 | 62.0 | False | None | None | False | None | False | 17707.2 | 0 |
3589701 | 130582 | None | code44 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. a) Ground floor | Sqm | 8925.28 | 8925.28 | 146.0 | False | None | None | False | None | False | 1303090.88 | 0 |
3589702 | 130582 | None | code45 | First floor | Sqm | 9014.53 | 9014.53 | 146.0 | False | None | None | False | None | False | 1316121.38 | 0 |
3589703 | 130582 | None | code46 | Terrace floor | Sqm | 9103.78 | 9103.78 | 50.0 | False | None | None | False | None | False | 455189.0 | 0 |
3589704 | 130582 | None | code47 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
a) Ground floor | Sqm | 1156.96 | 1156.96 | 117.0 | False | None | None | False | None | False | 135364.32 | 0 |
3589705 | 130582 | None | code48 | First floor | Sqm | 1168.52 | 1168.52 | 117.0 | False | None | None | False | None | False | 136716.84 | 0 |
3589706 | 130582 | None | code49 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Ground Floor | Sqm | 204.96 | 204.96 | 925.0 | False | None | None | False | None | False | 189588.0 | 0 |
3589707 | 130582 | None | code50 | First floor | Sqm | 207.0 | 207.0 | 925.0 | False | None | None | False | None | False | 191475.0 | 0 |
3589708 | 130582 | None | code51 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made Ground floor | Sqm | 7542.08 | 7542.08 | 29.0 | False | None | None | False | None | False | 218720.32 | 0 |
3589709 | 130582 | None | code52 | First floor | Sqm | 7617.5 | 7617.5 | 29.0 | False | None | None | False | None | False | 220907.5 | 0 |
3589710 | 130582 | None | code53 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
a)Stilt Floor | Sqm | 6405.28 | 6405.28 | 3.5 | False | None | None | False | None | False | 22418.48 | 0 |
3589711 | 130582 | None | code54 | First floor | Sqm | 6469.33 | 6469.33 | 3.5 | False | None | None | False | None | False | 22642.655 | 0 |
3589712 | 130582 | None | code55 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground Floor | Sqm | 154.56 | 154.56 | 259.0 | False | None | None | False | None | False | 40031.04 | 0 |
3589713 | 130582 | None | code56 | First floor | Sqm | 156.1 | 156.1 | 259.0 | False | None | None | False | None | False | 40429.9 | 0 |
3589714 | 130582 | None | code57 | MS FRAMES
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
a) Ground floor | Sqm | 152.32 | 152.32 | 410.0 | False | None | None | False | None | False | 62451.2 | 0 |
3589715 | 130582 | None | code58 | First floor | Sqm | 153.84 | 153.84 | 410.0 | False | None | None | False | None | False | 63074.4 | 0 |
3589716 | 130582 | None | code59 | Terrace floor | Sqm | 155.36 | 155.36 | 520.0 | False | None | None | False | None | False | 80787.2 | 0 |
3589717 | 130582 | None | code60 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. Ground Floor | Sqm | 5847.52 | 5847.52 | 53.0 | False | None | None | False | None | False | 309918.56 | 0 |
3589718 | 130582 | None | code61 | First floor | Sqm | 5905.99 | 5905.99 | 53.0 | False | None | None | False | None | False | 313017.47 | 0 |
3589719 | 130582 | None | code62 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² Terrace floor | Sqm | 1014.01 | 1014.01 | 38.0 | False | None | None | False | None | False | 38532.38 | 0 |
3589720 | 130582 | None | code63 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.a) Ground Floor | Sqm | 110672.8 | 110672.8 | 1.0 | False | None | None | False | None | False | 110672.8 | 0 |
3589721 | 130582 | None | code64 | First floor | Sqm | 111779.52 | 111779.52 | 1.0 | False | None | None | False | None | False | 111779.52 | 0 |
3589722 | 130582 | None | code65 | Terrace floor | Sqm | 112886.25 | 112886.25 | 0.1 | False | None | None | False | None | False | 11288.625 | 0 |
3589723 | 130582 | None | code66 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) a) Ground Floor | Sqm | 7365.12 | 7365.12 | 35.0 | False | None | None | False | None | False | 257779.2 | 0 |
3589724 | 130582 | None | code67 | First floor | Sqm | 7438.77 | 7438.77 | 35.0 | False | None | None | False | None | False | 260356.95 | 0 |
3589725 | 130582 | None | code68 | Terrace floor | Sqm | 7512.42 | 7512.42 | 2.0 | False | None | None | False | None | False | 15024.84 | 0 |
3589726 | 130582 | None | code69 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)
Size 62 x 100mm Ground floor | Sqm | 786.24 | 786.24 | 42.0 | False | None | None | False | None | False | 33022.08 | 0 |
3589727 | 130582 | None | code70 | First floor | Sqm | 794.1 | 794.1 | 42.0 | False | None | None | False | None | False | 33352.2 | 0 |
3589728 | 130582 | None | code71 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)
30 mm thickness Ground floor | Sqm | 3903.2 | 3903.2 | 6.5 | False | None | None | False | None | False | 25370.8 | 0 |
3589729 | 130582 | None | code72 | First floor | Sqm | 3942.23 | 3942.23 | 6.5 | False | None | None | False | None | False | 25624.495 | 0 |
3589730 | 130582 | None | code73 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Ground Floor | Sqm | 1137.92 | 1137.92 | 16.0 | False | None | None | False | None | False | 18206.72 | 0 |
3589731 | 130582 | None | code74 | First floor | Sqm | 1149.29 | 1149.29 | 16.0 | False | None | None | False | None | False | 18388.64 | 0 |
3589732 | 130582 | None | code75 | Terrace floor | Sqm | 1160.67 | 1160.67 | 1.0 | False | None | None | False | None | False | 1160.67 | 0 |
3589733 | 130582 | None | code76 | Providing and fixing SS 304 Aldrop-250mm x 16mm (variation in size acceptable upto + / - 10%) suitable for door shutters including SS screws cost of materials, labour etc., complete as per specifications of vendor details.Make: Dorset / Godrej / Niell / Archis / Kadson / AKS / equivalent Model as per Specification. | Sqm | 1910.0 | 1910.0 | 33.0 | False | None | None | False | None | False | 63030.0 | 0 |
3589734 | 130582 | None | code77 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
a) Ground Floor | Sqm | 1178.24 | 1178.24 | 16.0 | False | None | None | False | None | False | 18851.84 | 0 |
3589735 | 130582 | None | code78 | First floor | Sqm | 1190.02 | 1190.02 | 16.0 | False | None | None | False | None | False | 19040.32 | 0 |
3589736 | 130582 | None | code79 | Terrace floor | Sqm | 1201.8 | 1201.8 | 1.0 | False | None | None | False | None | False | 1201.8 | 0 |
3589737 | 130582 | None | code80 | Providing and fixing bright finished brass handles with screws etc. complete:
Brass handles 125 mm with plate 175x32 mm Ground floor | Sqm | 278.88 | 278.88 | 32.0 | False | None | None | False | None | False | 8924.16 | 0 |
3589738 | 130582 | None | code81 | First floor | Sqm | 281.66 | 281.66 | 32.0 | False | None | None | False | None | False | 9013.12 | 0 |
3589739 | 130582 | None | code82 | Terrace floor | Sqm | 284.45 | 284.45 | 2.0 | False | None | None | False | None | False | 568.9 | 0 |
3589740 | 130582 | None | code83 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete | Sqm | 264.32 | 264.32 | 16.0 | False | None | None | False | None | False | 4229.12 | 0 |
3589741 | 130582 | None | code84 | First floor | Sqm | 266.96 | 266.96 | 16.0 | False | None | None | False | None | False | 4271.36 | 0 |
3589742 | 130582 | None | code85 | Terrace floor | Sqm | 269.6 | 269.6 | 1.0 | False | None | None | False | None | False | 269.6 | 0 |
3589743 | 130582 | None | code86 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :
125x85x5.5 mm (heavy type) | Sqm | 308.0 | 308.0 | 48.0 | False | None | None | False | None | False | 14784.0 | 0 |
3589744 | 130582 | None | code87 | First floor | Sqm | 311.08 | 311.08 | 48.0 | False | None | None | False | None | False | 14931.84 | 0 |
3589745 | 130582 | None | code88 | Terrace floor | Sqm | 314.15 | 314.15 | 3.0 | False | None | None | False | None | False | 942.45 | 0 |
3589746 | 130582 | None | code89 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :
250x10mm Ground Floor | Sqm | 487.2 | 487.2 | 36.0 | False | None | None | False | None | False | 17539.2 | 0 |
3589747 | 130582 | None | code90 | First floor | Sqm | 492.07 | 492.07 | 36.0 | False | None | None | False | None | False | 17714.52 | 0 |
3589748 | 130582 | None | code91 | Terrace floor | Sqm | 496.94 | 496.94 | 2.0 | False | None | None | False | None | False | 993.88 | 0 |
3589749 | 130582 | None | code92 | Providing supply and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris,keeping the area clean,curing, labour etc., complete as per specifications of vendor and as per architects details. Stilt Floor ---- ETC... AS PER SPECIFICATION & DIRECTION OF ENGINEER IN CHARGE | Sqm | 45.0 | 45.0 | 198.0 | False | None | None | False | None | False | 8910.0 | 0 |
3589750 | 130582 | None | code93 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Terrace | Sqm | 933.34 | 933.34 | 483.0 | False | None | None | False | None | False | 450803.22 | 0 |
3589751 | 130582 | None | code94 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 833.69 | 833.69 | 48.0 | False | None | None | False | None | False | 40017.12 | 0 |
3589752 | 130582 | None | code95 | High Density Polyethylene Membrane water proofing
Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412, elongation of 500% as per ASTM D 41, puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m as per ASTM D 5385. The system should be fully bonded to the RCC thereby conforming to IS 164712017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect selfadhesive polymer layer, etc, including surface preparation completely as per specification. | Sqm | 677.6 | 677.6 | 11.0 | False | None | None | False | None | False | 7453.6 | 0 |
3589753 | 130582 | None | code96 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications. First floor | Sqm | 2281.63 | 2281.63 | 9.0 | False | None | None | False | None | False | 20534.67 | 0 |
3589754 | 130582 | None | code97 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
a) Stilt Floor | Sqm | 7032.67 | 7032.67 | 3.0 | False | None | None | False | None | False | 21098.01 | 0 |
3589755 | 130582 | None | code98 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GROUND FLOOR | Sqm | 3194.24 | 3194.24 | 83.0 | False | None | None | False | None | False | 265121.92 | 0 |
3589756 | 130582 | None | code99 | First floor | Sqm | 3226.18 | 3226.18 | 82.0 | False | None | None | False | None | False | 264546.76 | 0 |
3589757 | 130582 | None | code100 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. GROUND FLOOR | Sqm | 367.36 | 367.36 | 47.0 | False | None | None | False | None | False | 17265.92 | 0 |
3589758 | 130582 | None | code101 | First floor | Sqm | 371.03 | 371.03 | 47.0 | False | None | None | False | None | False | 17438.41 | 0 |
3589759 | 130582 | None | code102 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm a) Ground floor | Sqm | 1316.0 | 1316.0 | 312.0 | False | None | None | False | None | False | 410592.0 | 0 |
3589760 | 130582 | None | code103 | First floor | Sqm | 1329.16 | 1329.16 | 312.0 | False | None | None | False | None | False | 414697.92 | 0 |
3589761 | 130582 | None | code104 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Ground Floor | Sqm | 995.68 | 995.68 | 44.0 | False | None | None | False | None | False | 43809.92 | 0 |
3589762 | 130582 | None | code105 | First floor | Sqm | 1005.63 | 1005.63 | 44.0 | False | None | None | False | None | False | 44247.72 | 0 |
3589763 | 130582 | None | code106 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1622.88 | 1622.88 | 213.0 | False | None | None | False | None | False | 345673.44 | 0 |
3589764 | 130582 | None | code107 | First floor | Sqm | 1639.1 | 1639.1 | 213.0 | False | None | None | False | None | False | 349128.3 | 0 |
3589765 | 130582 | None | code108 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. Ground Floor | Sqm | 4792.48 | 4792.48 | 31.0 | False | None | None | False | None | False | 148566.88 | 0 |
3589766 | 130582 | None | code109 | First floor | Sqm | 4840.4 | 4840.4 | 31.0 | False | None | None | False | None | False | 150052.4 | 0 |
3589767 | 130582 | None | code110 | Finishing works
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Internal wall plastering | Sqm | 312.48 | 312.48 | 1169.0 | False | None | None | False | None | False | 365289.12 | 0 |
3589768 | 130582 | None | code111 | First floor | Sqm | 315.6 | 315.6 | 1169.0 | False | None | None | False | None | False | 368936.4 | 0 |
3589769 | 130582 | None | code112 | Terrace floor | Sqm | 318.72 | 318.72 | 74.0 | False | None | None | False | None | False | 23585.28 | 0 |
3589770 | 130582 | None | code113 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Rough plastering Ground Floor | Sqm | 330.4 | 330.4 | 213.0 | False | None | None | False | None | False | 70375.2 | 0 |
3589771 | 130582 | None | code114 | First floor | Sqm | 333.7 | 333.7 | 213.0 | False | None | None | False | None | False | 71078.1 | 0 |
3589772 | 130582 | None | code115 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
External Plastering | Sqm | 431.2 | 431.2 | 518.0 | False | None | None | False | None | False | 223361.6 | 0 |
3589773 | 130582 | None | code116 | First floor | Sqm | 435.51 | 435.51 | 518.0 | False | None | None | False | None | False | 225594.18 | 0 |
3589774 | 130582 | None | code117 | TERRACE AND HEADROOM | Sqm | 439.82 | 439.82 | 379.0 | False | None | None | False | None | False | 166691.78 | 0 |
3589775 | 130582 | None | code118 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment
Plaster mesh 100mm wide | Sqm | 49.28 | 49.28 | 913.0 | False | None | None | False | None | False | 44992.64 | 0 |
3589776 | 130582 | None | code119 | First floor | Sqm | 49.77 | 49.77 | 913.0 | False | None | None | False | None | False | 45440.01 | 0 |
3589777 | 130582 | None | code120 | Terrace floor | Sqm | 50.26 | 50.26 | 528.0 | False | None | None | False | None | False | 26537.28 | 0 |
3589778 | 130582 | None | code121 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
(a) Stilt Floor GROUND FLOOR | Sqm | 112.0 | 112.0 | 1613.0 | False | None | None | False | None | False | 180656.0 | 0 |
3589779 | 130582 | None | code122 | First floor | Sqm | 113.12 | 113.12 | 1613.0 | False | None | None | False | None | False | 182462.56 | 0 |
3589780 | 130582 | None | code123 | Terrace floor | Sqm | 114.24 | 114.24 | 74.0 | False | None | None | False | None | False | 8453.76 | 0 |
3589781 | 130582 | None | code124 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 182.56 | 182.56 | 1613.0 | False | None | None | False | None | False | 294469.28 | 0 |
3589782 | 130582 | None | code125 | First floor | Sqm | 184.38 | 184.38 | 1613.0 | False | None | None | False | None | False | 297404.94 | 0 |
3589783 | 130582 | None | code126 | Terrace floor | Sqm | 186.21 | 186.21 | 74.0 | False | None | None | False | None | False | 13779.54 | 0 |
3589784 | 130582 | None | code127 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
a) Ground Floor | Sqm | 316.96 | 316.96 | 22.0 | False | None | None | False | None | False | 6973.12 | 0 |
3589785 | 130582 | None | code128 | First floor | Sqm | 320.12 | 320.12 | 22.0 | False | None | None | False | None | False | 7042.64 | 0 |
3589786 | 130582 | None | code129 | TERRACE | Sqm | 323.29 | 323.29 | 10.0 | False | None | None | False | None | False | 3232.9 | 0 |
3589787 | 130582 | None | code130 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. &
Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
a) Ground Floor | Sqm | 159.04 | 159.04 | 496.0 | False | None | None | False | None | False | 78883.84 | 0 |
3589788 | 130582 | None | code131 | First floor | Sqm | 160.63 | 160.63 | 496.0 | False | None | None | False | None | False | 79672.48 | 0 |
3589789 | 130582 | None | code132 | TERRACE | Sqm | 162.22 | 162.22 | 370.0 | False | None | None | False | None | False | 60021.4 | 0 |
3589790 | 130582 | None | code133 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor | Sqm | 187.04 | 187.04 | 68.0 | False | None | None | False | None | False | 12718.72 | 0 |
3589791 | 130582 | None | code134 | First floor | Sqm | 188.91 | 188.91 | 68.0 | False | None | None | False | None | False | 12845.88 | 0 |
3589792 | 130582 | None | code135 | Terrace floor | Sqm | 190.78 | 190.78 | 10.0 | False | None | None | False | None | False | 1907.8 | 0 |
3589793 | 130582 | None | code136 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
a) Ground Floor | Sqm | 758.24 | 758.24 | 115.0 | False | None | None | False | None | False | 87197.6 | 0 |
3589794 | 130582 | None | code137 | First floor | Sqm | 765.82 | 765.82 | 111.0 | False | None | None | False | None | False | 85006.02 | 0 |
3589795 | 130582 | None | code138 | terrace floor | Sqm | 773.4 | 773.4 | 7.0 | False | None | None | False | None | False | 5413.8 | 0 |
3589796 | 130582 | None | code139 | Providing drip moulding with plastering of 25mmx 100mm in cement plaster 1:4 with rendering for projected surface ,provding and removing the cost of scaffolding inculding cost of material , labours curing as per specifications | Sqm | 25.0 | 25.0 | 458.0 | False | None | None | False | None | False | 11450.0 | 0 |
3589797 | 130582 | None | code140 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap Ground Floor | Sqm | 3209.92 | 3209.92 | 12.0 | False | None | None | False | None | False | 38519.04 | 0 |
3589798 | 130582 | None | code141 | 1st Floor | Sqm | 3242.01 | 3242.01 | 12.0 | False | None | None | False | None | False | 38904.12 | 0 |
3589799 | 130582 | None | code142 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. Ground Floor | Sqm | 12570.88 | 12570.88 | 4.0 | False | None | None | False | None | False | 50283.52 | 0 |
3589800 | 130582 | None | code143 | 1st Floor | Sqm | 12696.58 | 12696.58 | 4.0 | False | None | None | False | None | False | 50786.32 | 0 |
3589801 | 130582 | None | code144 | Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete.
Make : | Sqm | 3000.0 | 3000.0 | 16.0 | False | None | None | False | None | False | 48000.0 | 0 |
3589802 | 130582 | None | code145 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
Ground Floor | Sqm | 483.84 | 483.84 | 4.0 | False | None | None | False | None | False | 1935.36 | 0 |
3589803 | 130582 | None | code146 | 1st Floor | Sqm | 488.67 | 488.67 | 4.0 | False | None | None | False | None | False | 1954.68 | 0 |
3589804 | 130582 | None | code147 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Ground Floor | Sqm | 812.0 | 812.0 | 16.0 | False | None | None | False | None | False | 12992.0 | 0 |
3589805 | 130582 | None | code148 | 1st Floor | Sqm | 820.12 | 820.12 | 16.0 | False | None | None | False | None | False | 13121.92 | 0 |
3589806 | 130582 | None | code149 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Ground Floor | Sqm | 1366.4 | 1366.4 | 12.0 | False | None | None | False | None | False | 16396.8 | 0 |
3589807 | 130582 | None | code150 | 1st Floor | Sqm | 1380.06 | 1380.06 | 12.0 | False | None | None | False | None | False | 16560.72 | 0 |
3589808 | 130582 | None | code151 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
Kitchen sink without drain board 610x510 mm bowl depth 200 mm Ground Floor | Sqm | 4060.0 | 4060.0 | 8.0 | False | None | None | False | None | False | 32480.0 | 0 |
3589809 | 130582 | None | code152 | 1st Floor | Sqm | 4100.6 | 4100.6 | 8.0 | False | None | None | False | None | False | 32804.8 | 0 |
3589810 | 130582 | None | code153 | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class ( Premium ) Ground Floor | Sqm | 3232.32 | 3232.32 | 8.0 | False | None | None | False | None | False | 25858.56 | 0 |
3589811 | 130582 | None | code154 | 1st Floor | Sqm | 3264.64 | 3264.64 | 8.0 | False | None | None | False | None | False | 26117.12 | 0 |
3589812 | 130582 | None | code155 | Providing and fixing 2 in 1 Wall Mixer with complete fitting comprising of with provision for with long bend spout for bucket with wall flange complete. | Sqm | 5100.0 | 5100.0 | 16.0 | False | None | None | False | None | False | 81600.0 | 0 |
3589813 | 130582 | None | code156 | Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. | Sqm | 678.0 | 678.0 | 16.0 | False | None | None | False | None | False | 10848.0 | 0 |
3589814 | 130582 | None | code157 | Supplying & fixing of CP sink mixer with swivel spout with wall flange etc complete. | Sqm | 1956.0 | 1956.0 | 16.0 | False | None | None | False | None | False | 31296.0 | 0 |
3589815 | 130582 | None | code158 | Providing and fixing shower head Arm with rose long bend free flow with fitting wall flange complete, including teflon with fixing. | Sqm | 2316.0 | 2316.0 | 16.0 | False | None | None | False | None | False | 37056.0 | 0 |
3589816 | 130582 | None | code159 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ground floor | Sqm | 555.52 | 555.52 | 12.0 | False | None | None | False | None | False | 6666.24 | 0 |
3589817 | 130582 | None | code160 | first floor | Sqm | 561.08 | 561.08 | 12.0 | False | None | None | False | None | False | 6732.96 | 0 |
3589818 | 130582 | None | code161 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.
Orissa pattern W.C Pan of size 580x440 mm Ground Floor | Sqm | 3972.64 | 3972.64 | 4.0 | False | None | None | False | None | False | 15890.56 | 0 |
3589819 | 130582 | None | code162 | 1st Floor | Sqm | 4012.36 | 4012.36 | 4.0 | False | None | None | False | None | False | 16049.44 | 0 |
3589820 | 130582 | None | code163 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
40mm Dia Ground Floor | Sqm | 98.56 | 98.56 | 48.0 | False | None | None | False | None | False | 4730.88 | 0 |
3589821 | 130582 | None | code164 | 1st Floor | Sqm | 99.44 | 99.44 | 48.0 | False | None | None | False | None | False | 4773.12 | 0 |
3589822 | 130582 | None | code165 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 75mm dia., 6 kg/sqcm & class 3 Ground Floor | Sqm | 246.4 | 246.4 | 56.0 | False | None | None | False | None | False | 13798.4 | 0 |
3589823 | 130582 | None | code166 | 1st Floor | Sqm | 248.86 | 248.86 | 56.0 | False | None | None | False | None | False | 13936.16 | 0 |
3589824 | 130582 | None | code167 | Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments | Sqm | 75.03 | 75.03 | 20.0 | False | None | None | False | None | False | 1500.6 | 0 |
3589825 | 130582 | None | code168 | Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Sqm | 215.04 | 215.04 | 20.0 | False | None | None | False | None | False | 4300.8 | 0 |
3589826 | 130582 | None | code169 | Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Sqm | 131.04 | 131.04 | 20.0 | False | None | None | False | None | False | 2620.8 | 0 |
3589827 | 130582 | None | code170 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 110mm dia., 6 kg/sqcm & class 3 Ground Floor | Sqm | 460.32 | 460.32 | 32.0 | False | None | None | False | None | False | 14730.24 | 0 |
3589828 | 130582 | None | code171 | 1st Floor | Sqm | 464.92 | 464.92 | 62.0 | False | None | None | False | None | False | 28825.04 | 0 |
3589829 | 130582 | None | code172 | Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments | Sqm | 191.52 | 191.52 | 20.0 | False | None | None | False | None | False | 3830.4 | 0 |
3589830 | 130582 | None | code173 | Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Sqm | 338.24 | 338.24 | 20.0 | False | None | None | False | None | False | 6764.8 | 0 |
3589831 | 130582 | None | code174 | Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Sqm | 281.12 | 281.12 | 20.0 | False | None | None | False | None | False | 5622.4 | 0 |
3589832 | 130582 | None | code175 | Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete.. | Sqm | 552.0 | 552.0 | 40.0 | False | None | None | False | None | False | 22080.0 | 0 |
3589833 | 130582 | None | code176 | Supplying and fixing PVC P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floors. | Sqm | 732.0 | 732.0 | 8.0 | False | None | None | False | None | False | 5856.0 | 0 |
3589834 | 130582 | None | code177 | Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete. | Sqm | 282.0 | 282.0 | 48.0 | False | None | None | False | None | False | 13536.0 | 0 |
3589835 | 130582 | None | code178 | Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete
Size : 150 mm dia | Sqm | 720.0 | 720.0 | 32.0 | False | None | None | False | None | False | 23040.0 | 0 |
3589836 | 130582 | None | code179 | Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc.
20 mm dia pipe nominal OD pipes Ground Floor | Sqm | 424.48 | 424.48 | 165.6 | False | None | None | False | None | False | 70293.888 | 0 |
3589837 | 130582 | None | code180 | 1st Floor | Sqm | 475.41 | 475.41 | 506.0 | False | None | None | False | None | False | 240557.46 | 0 |
3589838 | 130582 | None | code181 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20mm nominal bore | Sqm | 351.68 | 351.68 | 12.0 | False | None | None | False | None | False | 4220.16 | 0 |
3589839 | 130582 | None | code182 | Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work)
20 mm dia pipe nominal OD pipes | Sqm | 243.04 | 243.04 | 160.0 | False | None | None | False | None | False | 38886.4 | 0 |
3589840 | 130582 | None | code183 | Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work
25 mm dia pipe nominal OD pipes | Sqm | 331.52 | 331.52 | 96.0 | False | None | None | False | None | False | 31825.92 | 0 |
3589841 | 130582 | None | code184 | Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work
32 mm dia pipe nominal OD pipes | Sqm | 416.64 | 416.64 | 142.0 | False | None | None | False | None | False | 59162.88 | 0 |
3589842 | 130582 | None | code185 | Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work
40 mm dia pipe nominal OD pipes | Sqm | 534.24 | 534.24 | 122.0 | False | None | None | False | None | False | 65177.28 | 0 |
3589843 | 130582 | None | code186 | Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work
50 mm dia pipe nominal OD pipes | Sqm | 807.52 | 807.52 | 40.0 | False | None | None | False | None | False | 32300.8 | 0 |
3589844 | 130582 | None | code187 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20mm nominal bore | Sqm | 351.68 | 351.68 | 10.0 | False | None | None | False | None | False | 3516.8 | 0 |
3589845 | 130582 | None | code188 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :
25mm nominal bore | Sqm | 614.88 | 614.88 | 8.0 | False | None | None | False | None | False | 4919.04 | 0 |
3589846 | 130582 | None | code189 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :
32mm nominal bore | Sqm | 669.76 | 669.76 | 8.0 | False | None | None | False | None | False | 5358.08 | 0 |
3589847 | 130582 | None | code190 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :
40mm nominal bore | Sqm | 786.24 | 786.24 | 6.0 | False | None | None | False | None | False | 4717.44 | 0 |
3589848 | 130582 | None | code191 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :
50mm nominal bore | Sqm | 957.6 | 957.6 | 4.0 | False | None | None | False | None | False | 3830.4 | 0 |
3589849 | 130582 | None | code192 | Providing and placing on terrace, polyethylene water storage tanks As per IS 12701 Marked with cover and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes But with out fittings and the base support for the tank | Sqm | 10.17 | 10.17 | 4000.0 | False | None | None | False | None | False | 40680.0 | 0 |
3589850 | 130582 | None | code193 | Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia | Sqm | 4344.0 | 4344.0 | 2.0 | False | None | None | False | None | False | 8688.0 | 0 |
3589851 | 130582 | None | code194 | Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC Grating | Sqm | 830.0 | 830.0 | 8.0 | False | None | None | False | None | False | 6640.0 | 0 |
3589852 | 130582 | None | code195 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 75mm dia., 6 kg/sqcm & class 3 | Sqm | 246.4 | 246.4 | 234.0 | False | None | None | False | None | False | 57657.6 | 0 |
3589853 | 130582 | None | code196 | Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments75mm dia PVC couplers | Sqm | 75.03 | 75.03 | 60.0 | False | None | None | False | None | False | 4501.8 | 0 |
3589854 | 130582 | None | code197 | Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments75 mm dia PVC Elbows | Sqm | 215.04 | 215.04 | 60.0 | False | None | None | False | None | False | 12902.4 | 0 |
3589855 | 130582 | None | code198 | Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments75 mm dia PVC Tee | Sqm | 131.04 | 131.04 | 50.0 | False | None | None | False | None | False | 6552.0 | 0 |
3589856 | 130582 | None | code199 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Sqm | 460.32 | 460.32 | 238.0 | False | None | None | False | None | False | 109556.16 | 0 |
3589857 | 130582 | None | code200 | Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments.110mm dia PVC couplers
110mm dia PVC couplers | Sqm | 191.52 | 191.52 | 50.0 | False | None | None | False | None | False | 9576.0 | 0 |
3589858 | 130582 | None | code201 | Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments110mm dia PVC Elbows | Sqm | 338.24 | 338.24 | 40.0 | False | None | None | False | None | False | 13529.6 | 0 |
3589859 | 130582 | None | code202 | Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendment110 mm dia PVC Tees | Sqm | 281.12 | 281.12 | 40.0 | False | None | None | False | None | False | 11244.8 | 0 |
3589860 | 130582 | None | code203 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
160mm dia PVC pipe160mm dia PVC pipe | Sqm | 692.16 | 692.16 | 70.0 | False | None | None | False | None | False | 48451.2 | 0 |
3589861 | 130582 | None | code204 | Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments160mm dia PVC couplers | Sqm | 375.2 | 375.2 | 20.0 | False | None | None | False | None | False | 7504.0 | 0 |
3589862 | 130582 | None | code205 | Supply and delivery at site special moulded variety 160mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments160mm dia PVC Elbows | Sqm | 527.52 | 527.52 | 20.0 | False | None | None | False | None | False | 10550.4 | 0 |
3589863 | 130582 | None | code206 | Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments | Sqm | 521.92 | 521.92 | 20.0 | False | None | None | False | None | False | 10438.4 | 0 |
3589864 | 130582 | None | code207 | Providing And fixing Square mouth stone ware gully trap SP-1 Complete With CI Grating Brick Masonry Chamber 100x100mm Size P trap With Non modular common burnt bricks of designation 3.5, with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 KG, and frame to be not less than 2.70Kg as per the standard design | Sqm | 2835.84 | 2835.84 | 12.0 | False | None | None | False | None | False | 34030.08 | 0 |
3589865 | 130582 | None | code208 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Sqm | 6319.04 | 6319.04 | 10.0 | False | None | None | False | None | False | 63190.4 | 0 |
3589866 | 130582 | None | code209 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces,disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Sqm | 644.0 | 644.0 | 156.6 | False | None | None | False | None | False | 100850.4 | 0 |
3589867 | 130582 | None | code210 | DOMESTIC WATER TRANSFAR PUMP
Supplying, installing, testing and commissioning of submersible / Mono blockelectrical driven pump 1set . (1 working & standby) domestic water pumps for pumping domestic water from U.G. sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete.
Duty of the Pump
4 cum per hour at 20 TO 25 m head
Make : Kirloskar/ suguna/texmo/CRI
two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors. | Sqm | 24000.0 | 24000.0 | 1.0 | False | None | None | False | None | False | 24000.0 | 0 |
3589868 | 130582 | None | code211 | Providing and fixing gun metal non- return valve of approved quality
(screwed end)
32 mm nominal bore | Sqm | 1036.0 | 1036.0 | 2.0 | False | None | None | False | None | False | 2072.0 | 0 |
3589869 | 130582 | None | code212 | Providing and fixing gun metal non- return valve of approved quality
(screwed end)
40 mm nominal bore | Sqm | 1372.0 | 1372.0 | 2.0 | False | None | None | False | None | False | 2744.0 | 0 |
3589870 | 130582 | None | code213 | Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm & depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frame. | Sqm | 6920.4 | 6920.4 | 6.0 | False | None | None | False | None | False | 41522.4 | 0 |
3589871 | 130582 | None | code214 | Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, coveringthe top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc. The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor. The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration. 3 Nos. bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually.Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration.
Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer - in charge. | Sqm | 27883.0 | 27883.0 | 2.0 | False | None | None | False | None | False | 55766.0 | 0 |
3589872 | 130582 | None | code215 | Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 32 mm dia | Sqm | 696.0 | 696.0 | 2.0 | False | None | None | False | None | False | 1392.0 | 0 |
3589873 | 130582 | None | code216 | 40 mm dia | Sqm | 828.0 | 828.0 | 2.0 | False | None | None | False | None | False | 1656.0 | 0 |
3589874 | 130582 | None | code217 | 50 mm dia | Sqm | 1044.0 | 1044.0 | 2.0 | False | None | None | False | None | False | 2088.0 | 0 |
3589875 | 130582 | None | code218 | 65 mm dia | Sqm | 1398.0 | 1398.0 | 2.0 | False | None | None | False | None | False | 2796.0 | 0 |
3589876 | 130582 | None | code219 | Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick | Sqm | 69.0 | 69.0 | 960.0 | False | None | None | False | None | False | 66240.0 | 0 |
3589877 | 130582 | None | code220 | 25mm dia 2mm thick | Sqm | 81.0 | 81.0 | 1200.0 | False | None | None | False | None | False | 97200.0 | 0 |
3589878 | 130582 | None | code221 | Groove cutting in the wall supplying ….dia 2mm/2.5mm thick heavy gauge PVC Conduit Pipe with bends, metal junction boxes adhesive paste etc.,and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Sqm | 68.0 | 68.0 | 800.0 | False | None | None | False | None | False | 54400.0 | 0 |
3589879 | 130582 | None | code222 | b) 25mm dia 2mm thick | Sqm | 79.0 | 79.0 | 600.0 | False | None | None | False | None | False | 47400.0 | 0 |
3589880 | 130582 | None | code223 | d) 40mm dia 2.5mm thick | Sqm | 99.0 | 99.0 | 200.0 | False | None | None | False | None | False | 19800.0 | 0 |
3589881 | 130582 | None | code224 | Supplying and flush mounting powder coated/galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way | Sqm | 138.0 | 138.0 | 40.0 | False | None | None | False | None | False | 5520.0 | 0 |
3589882 | 130582 | None | code225 | 4-5Way | Sqm | 177.0 | 177.0 | 16.0 | False | None | None | False | None | False | 2832.0 | 0 |
3589883 | 130582 | None | code226 | 6Way | Sqm | 220.0 | 220.0 | 56.0 | False | None | None | False | None | False | 12320.0 | 0 |
3589884 | 130582 | None | code227 | 8 Way | Sqm | 261.0 | 261.0 | 24.0 | False | None | None | False | None | False | 6264.0 | 0 |
3589885 | 130582 | None | code228 | 10-12Way | Sqm | 319.0 | 319.0 | 24.0 | False | None | None | False | None | False | 7656.0 | 0 |
3589886 | 130582 | None | code229 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Moudule | Sqm | 137.0 | 137.0 | 40.0 | False | None | None | False | None | False | 5480.0 | 0 |
3589887 | 130582 | None | code230 | 4 Moudule | Sqm | 175.0 | 175.0 | 16.0 | False | None | None | False | None | False | 2800.0 | 0 |
3589888 | 130582 | None | code231 | 6 Moudule | Sqm | 234.0 | 234.0 | 56.0 | False | None | None | False | None | False | 13104.0 | 0 |
3589889 | 130582 | None | code232 | 8 Moudule | Sqm | 284.0 | 284.0 | 24.0 | False | None | None | False | None | False | 6816.0 | 0 |
3589890 | 130582 | None | code233 | 12 Moudule | Sqm | 344.0 | 344.0 | 24.0 | False | None | None | False | None | False | 8256.0 | 0 |
3589891 | 130582 | None | code234 | Supplying and wiring adopting loop system in existingPVC Conduit /casing capping using 2x1.5Sqmm (Phase& Neutral) & 1x1.0 sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming toIS-694: and latest amendments) with a 6Amps flush typeSP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.1.1 Short point up to 3Mtr from tapping point to out let via switch box | Sqm | 285.0 | 285.0 | 60.0 | False | None | None | False | None | False | 17100.0 | 0 |
3589892 | 130582 | None | code235 | 2.1.2 Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box | Sqm | 394.0 | 394.0 | 70.0 | False | None | None | False | None | False | 27580.0 | 0 |
3589893 | 130582 | None | code236 | 2.1.3 Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box | Sqm | 570.0 | 570.0 | 70.0 | False | None | None | False | None | False | 39900.0 | 0 |
3589894 | 130582 | None | code237 | 2.1.4 Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Sqm | 708.0 | 708.0 | 20.0 | False | None | None | False | None | False | 14160.0 | 0 |
3589895 | 130582 | None | code238 | Supplying and fixing of modular switch & connected
accessories on existing modular switch plate as per IS 3854
and IS 1293. 6Amps one way switch | Sqm | 102.0 | 102.0 | 320.0 | False | None | None | False | None | False | 32640.0 | 0 |
3589896 | 130582 | None | code239 | 6Amps 3way socket. | Sqm | 171.0 | 171.0 | 160.0 | False | None | None | False | None | False | 27360.0 | 0 |
3589897 | 130582 | None | code240 | Stepped Fan Regulator. | Sqm | 357.0 | 357.0 | 32.0 | False | None | None | False | None | False | 11424.0 | 0 |
3589898 | 130582 | None | code241 | 32Amps DP switch | Sqm | 326.0 | 326.0 | 64.0 | False | None | None | False | None | False | 20864.0 | 0 |
3589899 | 130582 | None | code242 | 6/16Amps universal socket | Sqm | 236.0 | 236.0 | 64.0 | False | None | None | False | None | False | 15104.0 | 0 |
3589900 | 130582 | None | code243 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With low conductor resistance single core cable in open or concealed system of wiring with specified IS 694: Conforming to latest amendment 1.5 sqmm | Sqm | 26.0 | 26.0 | 2400.0 | False | None | None | False | None | False | 62400.0 | 0 |
3589901 | 130582 | None | code244 | 2.5 sqmm | Sqm | 42.0 | 42.0 | 2560.0 | False | None | None | False | None | False | 107520.0 | 0 |
3589902 | 130582 | None | code245 | 4 sqmm | Sqm | 63.0 | 63.0 | 1500.0 | False | None | None | False | None | False | 94500.0 | 0 |
3589903 | 130582 | None | code246 | 6 sqmm | Sqm | 92.0 | 92.0 | 640.0 | False | None | None | False | None | False | 58880.0 | 0 |
3589904 | 130582 | None | code247 | Supplying and fixing hylum brand hand plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. | Sqm | 0.35 | 0.35 | 47000.0 | False | None | None | False | None | False | 16450.0 | 0 |
3589905 | 130582 | None | code248 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Sqm | 63.0 | 63.0 | 160.0 | False | None | None | False | None | False | 10080.0 | 0 |
3589906 | 130582 | None | code249 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm)Regular model Regular model (Khaitan, Crompton Greaves, Orient, Polar, Bajaj, Havells) | Sqm | 2984.0 | 2984.0 | 32.0 | False | None | None | False | None | False | 95488.0 | 0 |
3589907 | 130582 | None | code250 | Fixing a ceiling / wall mounting fan of all capacities and all
types, with necessary clamps and 'S' hook made out of 15mmdia MS rod, with 5 amps. ceiling rose of approved qualitywith necessary length of 23 / 0.0076 inch PVC insulated twintwisted wire of approved quality, mounted on a suitable sizewooden board and wired. | Sqm | 315.0 | 315.0 | 32.0 | False | None | None | False | None | False | 10080.0 | 0 |
3589908 | 130582 | None | code251 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and coomplete wiring as required. To ICE 60898 6-32Amps SP | Sqm | 415.0 | 415.0 | 16.0 | False | None | None | False | None | False | 6640.0 | 0 |
3589909 | 130582 | None | code252 | 50-63Amps DP | Sqm | 1102.0 | 1102.0 | 16.0 | False | None | None | False | None | False | 17632.0 | 0 |
3589910 | 130582 | None | code253 | 50-63Amps TPN | Sqm | 3088.0 | 3088.0 | 8.0 | False | None | None | False | None | False | 24704.0 | 0 |
3589911 | 130582 | None | code254 | Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting.Made out of 14 SWG MS encloure. complete. II - Double Door, 12Way SP &N | Sqm | 2329.0 | 2329.0 | 8.0 | False | None | None | False | None | False | 18632.0 | 0 |
3589912 | 130582 | None | code255 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.(68/1) | Sqm | 2999.7 | 2999.7 | 8.0 | False | None | None | False | None | False | 23997.6 | 0 |
3589913 | 130582 | None | code256 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI STRIP 25X3mm | Sqm | 75.0 | 75.0 | 145.0 | False | None | None | False | None | False | 10875.0 | 0 |
3589914 | 130582 | None | code257 | Supplying of .....feet -PVC Batten with integrated LED tube.... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 2x 20 22 w | Sqm | 690.0 | 690.0 | 48.0 | False | None | None | False | None | False | 33120.0 | 0 |
3589915 | 130582 | None | code258 | Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall /ceiling/rafters/girders using 23/ 0.0076 twin twisted PVC insulated wires, required nos of round blocks and clamps (if required). a) On wa/ceiling/Rafter/Girders | Sqm | 122.0 | 122.0 | 64.0 | False | None | None | False | None | False | 7808.0 | 0 |
3589916 | 130582 | None | code259 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.(23/22) 12" Sweep (300mm) 12" Sweep (300mm), a.Group 'A' | Sqm | 2969.0 | 2969.0 | 24.0 | False | None | None | False | None | False | 71256.0 | 0 |
3589917 | 130582 | None | code260 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make. | Sqm | 492.0 | 492.0 | 24.0 | False | None | None | False | None | False | 11808.0 | 0 |
3589918 | 130582 | None | code261 | Supply of round/square recess/surface mounted rolling type
LED Down light with ...... W GU 10 LED Lamp Rib Fabricated
from diecast aluminium with white powder coated prewired to
mains connector & has swivelling unit of aluminium die cast eye ball
& LED Lamp position retained by circular wire spring, with Life of
25000 burning hours & 70% lumen maintenance with CRI 80.
Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE
LED square or round down light 15-18W | Sqm | 1324.0 | 1324.0 | 16.0 | False | None | None | False | None | False | 21184.0 | 0 |
3589919 | 130582 | None | code262 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Musical | Sqm | 434.0 | 434.0 | 8.0 | False | None | None | False | None | False | 3472.0 | 0 |
3589920 | 130582 | None | code263 | Supply of LED Streetlight luminaire with pressure die cast
aluminium housing body for optimal thermal dissipation.
Lamp compartment comprising of anti glare clear diffuser
with Injection moulded polycarbonate material, delivering
superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity shouldbe between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistanceof complete luminaire IK08. Power Factor 0.9 withmains, Surge Protection Min 5KV along with Over voltage Overload, short circuit/ miss-wiring protection. Compatiblefor pole mouting with outer dia of 40mm to 50mm. UniversalVoltage driver to operate wie voltage range from 100V to270V 5060Hz application. Compliance to IS 10322IEC60598, LM 79 LM 80 Adherence with RoHS. UL approvedMCPCB. Top access street light with single screw to ensureease of maintenance at the sight site location with minimizedminimal tools. LED Light fixture with ........W
SystemPowerconsumption.LEDEfficiency130lmwnominal CRI 75 Luminaire manufacturer should have in house facilityaccredited by NABLCPRI any Government certifiedagency & Design & Development facility certified by ISO9001:2008 . Housing with supplier word mark name shallbe Engraved Embossing on the die cast housing Bodypart. Warranty of 2 Years against any manufacturing defectworking under standard electrical conditions as mentionedabove should be given by LED manufacturer & CreeNichia Lumileds Osram make LED Source. 70 Watts | Sqm | 5992.0 | 5992.0 | 4.0 | False | None | None | False | None | False | 23968.0 | 0 |
3589921 | 130582 | None | code264 | Supplying & fixing...mm dia class A Gi pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on raii/RCC/wail/tubular pole, using suitable clamps, bolts and nuts and wiring using suitable capacity wires etc complete. Using 32mm dia G.I.pipe | Sqm | 1203.0 | 1203.0 | 4.0 | False | None | None | False | None | False | 4812.0 | 0 |
3589922 | 130582 | None | code265 | Fixing halogen/metal hallide/SVL/IL floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires complete. | Sqm | 162.0 | 162.0 | 6.0 | False | None | None | False | None | False | 972.0 | 0 |