tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1720446191000 | 0 | None | None | Buildings | CIVIL GF | 3836068.64 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3486317 | 124644 | None | PWD V- 3 SR 2023-24 Page No-7 It No-2.5 (II) A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle A.In area of light jungle ---- Complete as per Specification and as directed by the Engineer in-charge of work | 100 Sqm | 486.93 | 486.93 | 1.04 | False | None | None | False | None | False | 506.4072 | 0 | 3486318 | 124644 | None | PWD V- 2 SR 2023-24 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 117.7 | 117.7 | 26.04 | False | None | None | False | None | False | 3064.908 | 0 | 3486319 | 124644 | None | PWD V- 1 SR 2023-24 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 126.38 | 126.38 | 188.58 | False | None | None | False | None | False | 23832.7404 | 0 | 3486320 | 124644 | None | PWD V- 2 SR 2023-24 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @
3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 146.2 | 146.2 | 104.15 | False | None | None | False | None | False | 15226.73 | 0 | 3486321 | 124644 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7017.7 | 7017.7 | 27.72 | False | None | None | False | None | False | 194530.644 | 0 | 3486322 | 124644 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7789.59 | 7789.59 | 35.02 | False | None | None | False | None | False | 272791.4418 | 0 | 3486323 | 124644 | None | PWD V- 1 SR 2023-24 It No-1b | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Foundation upto Plinth b. All other types ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 623.17 | 623.17 | 35.02 | False | None | None | False | None | False | 21823.4134 | 0 | 3486324 | 124644 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse , COLUMNS aggregates Up to Plinth & Plinth beam ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7834.2 | 7834.2 | 19.41 | False | None | None | False | None | False | 152061.822 | 0 | 3486325 | 124644 | None | PWD V- 1 SR 2023-24 It No-8 | Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specificaiton. 8.Columns & Piers ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 5483.94 | 5483.94 | 2.32 | False | None | None | False | None | False | 12722.7408 | 0 | 3486326 | 124644 | None | PWD V- 1 SR 2023-24 It No-12 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Beams & Lintels of Building ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 3917.1 | 3917.1 | 17.09 | False | None | None | False | None | False | 66943.239 | 0 | 3486327 | 124644 | None | PWD V- 1 SR 2023-24 Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 587.28 | 587.28 | 210.58 | False | None | None | False | None | False | 123669.4224 | 0 | 3486328 | 124644 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Complete as per Specification and as directed by the Engineer in-charge of work | t | 110837.22 | 110837.22 | 5.29 | False | None | None | False | None | False | 586328.8938 | 0 | 3486329 | 124644 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNS, lintel, staircase, Roof beam & slab ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8214.57 | 8214.57 | 37.39 | False | None | None | False | None | False | 307142.7723 | 0 | 3486330 | 124644 | None | PWD V- 1 SR 2023-24 It No-8 | Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specificaiton. 8.Columns & Piers ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 5750.2 | 5750.2 | 6.09 | False | None | None | False | None | False | 35018.718 | 0 | 3486331 | 124644 | None | PWD V- 1 SR 2023-24 It No-12 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Beams & Lintels of Building ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4928.74 | 4928.74 | 12.01 | False | None | None | False | None | False | 59194.1674 | 0 | 3486332 | 124644 | None | PWD V- 1 SR 2023-24 It No-20 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Chejjas, Canopy & Other Architectural projections of minor sections ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 3696.56 | 3696.56 | 0.81 | False | None | None | False | None | False | 2994.2136 | 0 | 3486333 | 124644 | None | PWD V- 1 SR 2023-24 It No-20 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for staircase ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4107.28 | 4107.28 | 4.3 | False | None | None | False | None | False | 17661.304 | 0 | 3486334 | 124644 | None | PWD V- 1 SR 2023-24 It No-13 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for 13.Roof (Straight & Arched) ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4107.28 | 4107.28 | 15.02 | False | None | None | False | None | False | 61691.3456 | 0 | 3486335 | 124644 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7702.86 | 7702.86 | 1.54 | False | None | None | False | None | False | 11862.4044 | 0 | 3486336 | 124644 | None | PWD V- 1 SR 2023-24 It No-12 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Beams & Lintels of Building ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4621.71 | 4621.71 | 1.54 | False | None | None | False | None | False | 7117.4334 | 0 | 3486337 | 124644 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Complete as per Specification and as directed by the Engineer in-charge of work | t | 110837.22 | 110837.22 | 4.09 | False | None | None | False | None | False | 453324.2298 | 0 | 3486338 | 124644 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1623.09 | 1623.09 | 212.31 | False | None | None | False | None | False | 344598.2379 | 0 | 3486339 | 124644 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1367.85 | 1367.85 | 32.01 | False | None | None | False | None | False | 43784.8785 | 0 | 3486340 | 124644 | None | PWD V- 2 SR 2023-24 Page No-111 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 122431.78 | 122431.78 | 0.3 | False | None | None | False | None | False | 36729.534 | 0 | 3486341 | 124644 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1258.82 | 1258.82 | 8.0 | False | None | None | False | None | False | 10070.56 | 0 | 3486342 | 124644 | None | PWD V- 2 SR 2023-24 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Kg | 208.15 | 208.15 | 277.89 | False | None | None | False | None | False | 57842.8035 | 0 | 3486343 | 124644 | None | PWD V- 2 SR 2023-24 Page No-111 It No-12.96 | Providing & fixing Factory made 100% carpenter friendly ready to use Single Solid Plain Wood Polymer Composite (WPC) flush shutter of 30mm thickness which is anti termite and having high water absorption property. The cost includes cost of materials, transportation, labour and fixing charges. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 4309.24 | 4309.24 | 2.7 | False | None | None | False | None | False | 11634.948 | 0 | 3486344 | 124644 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 4115.95 | 4115.95 | 9.77 | False | None | None | False | None | False | 40212.8315 | 0 | 3486345 | 124644 | None | PWD V- 2 SR 2023-24 Page No-107 It No-12.74.1 | Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :125x64x1.90mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 126.38 | 126.38 | 24.0 | False | None | None | False | None | False | 3033.12 | 0 | 3486346 | 124644 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.76.2 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 433.65 | 433.65 | 16.0 | False | None | None | False | None | False | 6938.4 | 0 | 3486347 | 124644 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 293.64 | 293.64 | 16.0 | False | None | None | False | None | False | 4698.24 | 0 | 3486348 | 124644 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1226.61 | 1226.61 | 8.0 | False | None | None | False | None | False | 9812.88 | 0 | 3486349 | 124644 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 148.68 | 148.68 | 8.0 | False | None | None | False | None | False | 1189.44 | 0 | 3486350 | 124644 | None | PWD V- 2 SR 2023-24 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 74.34 | 74.34 | 32.0 | False | None | None | False | None | False | 2378.88 | 0 | 3486351 | 124644 | None | PWD V- 2 SR 2023-24 Page No-110 It No-12.90 | Providing & fixing of 3-track x 2 - panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through - out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware & Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm - 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 8343.42 | 8343.42 | 11.4 | False | None | None | False | None | False | 95114.988 | 0 | 3486352 | 124644 | None | PWD V- 2 SR 2023-24 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3486353 | 124644 | None | PWD V- 2 SR 2023-24 Page No-43 It No-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 261.43 | 261.43 | 97.14 | False | None | None | False | None | False | 25395.3102 | 0 | 3486354 | 124644 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 365.5 | 365.5 | 332.87 | False | None | None | False | None | False | 121663.985 | 0 | 3486355 | 124644 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 432.41 | 432.41 | 24.3 | False | None | None | False | None | False | 10507.563 | 0 | 3486356 | 124644 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 432.41 | 432.41 | 12.45 | False | None | None | False | None | False | 5383.5045 | 0 | 3486357 | 124644 | None | PWD V- 2 SR 2023-24 Page No-50 It No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 123.9 | 123.9 | 429.61 | False | None | None | False | None | False | 53228.679 | 0 | 3486358 | 124644 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 432.41 | 432.41 | 186.04 | False | None | None | False | None | False | 80445.5564 | 0 | 3486359 | 124644 | None | PWD V- 2 SR 2023-24 Page No-54 It No-8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 64.42 | 64.42 | 201.45 | False | None | None | False | None | False | 12977.409 | 0 | 3486360 | 124644 | None | PWD V- 2 SR 2021-22 Page No-60 It No-9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1455.82 | 1455.82 | 80.94 | False | None | None | False | None | False | 117834.0708 | 0 | 3486361 | 124644 | None | PWD V- 2 SR 2023-24 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1101.47 | 1101.47 | 7.2 | False | None | None | False | None | False | 7930.584 | 0 | 3486362 | 124644 | None | PWD V- 2 SR 2023-24 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1795.31 | 1795.31 | 24.3 | False | None | None | False | None | False | 43626.033 | 0 | 3486363 | 124644 | None | PWD V- 2 SR 2023-24 It No-9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 991.2 | 991.2 | 36.0 | False | None | None | False | None | False | 35683.2 | 0 | 3486364 | 124644 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 157.35 | 157.35 | 429.61 | False | None | None | False | None | False | 67599.1335 | 0 | 3486365 | 124644 | None | PWD V- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 193.28 | 193.28 | 186.04 | False | None | None | False | None | False | 35957.8112 | 0 | 3486366 | 124644 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 61.95 | 61.95 | 18.81 | False | None | None | False | None | False | 1165.2795 | 0 | 3486367 | 124644 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.43 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 116.46 | 116.46 | 18.81 | False | None | None | False | None | False | 2190.6126 | 0 | 3486368 | 124644 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 65.66 | 65.66 | 20.07 | False | None | None | False | None | False | 1317.7962 | 0 | 3486369 | 124644 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 142.49 | 142.49 | 20.07 | False | None | None | False | None | False | 2859.7743 | 0 | 3486370 | 124644 | None | PWD V- 2 SR 2021-22 Page No-83 It No-11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Kgs | 700.03 | 700.03 | 98.17 | False | None | None | False | None | False | 68721.9451 | 0 | 3486371 | 124644 | None | PWD V- 2 SR 2023-24 Page No-60 It No-9.6.1 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4coarse sand) Light shade pigment using white cement ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1572.29 | 1572.29 | 24.76 | False | None | None | False | None | False | 38929.9004 | 0 |
| 1720446191000 | 0 | None | None | Buildings | CIVIL - FF | 1803569.79 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3486372 | 124645 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, COLUMNS, lintel, staircase, Roof beam & slab ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8218.48 | 8218.48 | 23.72 | False | None | None | False | None | False | 194942.3456 | 0 | 3486373 | 124645 | None | PWD V- 1 SR 2023-24 It No-8 | Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specificaiton. 8.Columns & Piers ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 5752.93 | 5752.93 | 4.78 | False | None | None | False | None | False | 27499.0054 | 0 | 3486374 | 124645 | None | PWD V- 1 SR 2023-24 It No-12 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Beams & Lintels of Building ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4931.09 | 4931.09 | 10.88 | False | None | None | False | None | False | 53650.2592 | 0 | 3486375 | 124645 | None | PWD V- 1 SR 2023-24 It No-20 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Chejjas, Canopy & Other Architectural projections of minor sections ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 3698.32 | 3698.32 | 0.7 | False | None | None | False | None | False | 2588.824 | 0 | 3486376 | 124645 | None | PWD V- 1 SR 2023-24 It No-20 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for staircase ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4109.24 | 4109.24 | 3.16 | False | None | None | False | None | False | 12985.1984 | 0 | 3486377 | 124645 | None | PWD V- 1 SR 2023-24 It No-13 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for 13.Roof (Straight & Arched) ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4109.24 | 4109.24 | 8.96 | False | None | None | False | None | False | 36818.7904 | 0 | 3486378 | 124645 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings ---- Complete as per Specification and as directed by the Engineer in-charge of work | t | 110890.0 | 110890.0 | 2.39 | False | None | None | False | None | False | 265027.1 | 0 | 3486379 | 124645 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7706.53 | 7706.53 | 1.91 | False | None | None | False | None | False | 14719.4723 | 0 | 3486380 | 124645 | None | PWD V- 1 SR 2023-24 It No-12 | Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Beams & Lintels of Building ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4623.92 | 4623.92 | 1.91 | False | None | None | False | None | False | 8831.6872 | 0 | 3486381 | 124645 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1623.86 | 1623.86 | 189.17 | False | None | None | False | None | False | 307185.5962 | 0 | 3486382 | 124645 | None | PWD V- 2 SR 2023-24 Page No-14 It No-6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1368.5 | 1368.5 | 35.97 | False | None | None | False | None | False | 49224.945 | 0 | 3486383 | 124645 | None | PWD V- 2 SR 2023-24 Page No-111 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 122490.08 | 122490.08 | 0.25 | False | None | None | False | None | False | 30622.52 | 0 | 3486384 | 124645 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1259.42 | 1259.42 | 5.0 | False | None | None | False | None | False | 6297.1 | 0 | 3486385 | 124645 | None | PWD V- 2 SR 2023-24 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Kg | 208.24 | 208.24 | 231.25 | False | None | None | False | None | False | 48155.5 | 0 | 3486386 | 124645 | None | PWD V- 2 SR 2023-24 Page No-111 It No-12.96 | Providing & fixing Factory made 100% carpenter friendly ready to use Single Solid Plain Wood Polymer Composite (WPC) flush shutter of 30mm thickness which is anti termite and having high water absorption property. The cost includes cost of materials, transportation, labour and fixing charges. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 4311.29 | 4311.29 | 2.7 | False | None | None | False | None | False | 11640.483 | 0 | 3486387 | 124645 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 4117.91 | 4117.91 | 8.82 | False | None | None | False | None | False | 36319.9662 | 0 | 3486388 | 124645 | None | PWD V- 2 SR 2023-24 Page No-107 It No-12.74.1 | Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :125x64x1.90mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 126.43 | 126.43 | 18.0 | False | None | None | False | None | False | 2275.74 | 0 | 3486389 | 124645 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.76.2 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 433.86 | 433.86 | 12.0 | False | None | None | False | None | False | 5206.32 | 0 | 3486390 | 124645 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 293.78 | 293.78 | 12.0 | False | None | None | False | None | False | 3525.36 | 0 | 3486391 | 124645 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 1227.2 | 1227.2 | 6.0 | False | None | None | False | None | False | 7363.2 | 0 | 3486392 | 124645 | None | PWD V- 2 SR 2023-24 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 148.75 | 148.75 | 4.0 | False | None | None | False | None | False | 595.0 | 0 | 3486393 | 124645 | None | PWD V- 2 SR 2023-24 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 74.37 | 74.37 | 24.0 | False | None | None | False | None | False | 1784.88 | 0 | 3486394 | 124645 | None | PWD V- 2 SR 2023-24 Page No-110 It No-12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 8347.4 | 8347.4 | 9.75 | False | None | None | False | None | False | 81387.15 | 0 | 3486395 | 124645 | None | PWD V- 2 SR 2023-24 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 7089.21 | 7089.21 | 0.72 | False | None | None | False | None | False | 5104.2312 | 0 | 3486396 | 124645 | None | PWD V- 2 SR 2023-24 Page No-43 It No-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 261.55 | 261.55 | 55.47 | False | None | None | False | None | False | 14508.1785 | 0 | 3486397 | 124645 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 365.68 | 365.68 | 268.16 | False | None | None | False | None | False | 98060.7488 | 0 | 3486398 | 124645 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 432.61 | 432.61 | 24.97 | False | None | None | False | None | False | 10802.2717 | 0 | 3486399 | 124645 | None | PWD V- 2 SR 2023-24 Page No-50 It No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 123.95 | 123.95 | 330.05 | False | None | None | False | None | False | 40909.6975 | 0 | 3486400 | 124645 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 432.61 | 432.61 | 157.68 | False | None | None | False | None | False | 68213.9448 | 0 | 3486401 | 124645 | None | PWD V- 2 SR 2023-24 Page No-54 It No-8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 64.46 | 64.46 | 181.32 | False | None | None | False | None | False | 11687.8872 | 0 | 3486402 | 124645 | None | PWD V- 2 SR 2021-22 Page No-60 It No-9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1456.52 | 1456.52 | 56.16 | False | None | None | False | None | False | 81798.1632 | 0 | 3486403 | 124645 | None | PWD V- 2 SR 2023-24 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1101.99 | 1101.99 | 5.98 | False | None | None | False | None | False | 6589.9002 | 0 | 3486404 | 124645 | None | PWD V- 2 SR 2023-24 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1796.16 | 1796.16 | 24.97 | False | None | None | False | None | False | 44850.1152 | 0 | 3486405 | 124645 | None | PWD V- 2 SR 2023-24 It No-9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 991.67 | 991.67 | 116.49 | False | None | None | False | None | False | 115519.6383 | 0 | 3486406 | 124645 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 157.42 | 157.42 | 330.05 | False | None | None | False | None | False | 51956.471 | 0 | 3486407 | 124645 | None | PWD V- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 193.37 | 193.37 | 157.68 | False | None | None | False | None | False | 30490.5816 | 0 | 3486408 | 124645 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 61.98 | 61.98 | 9.72 | False | None | None | False | None | False | 602.4456 | 0 | 3486409 | 124645 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.43 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two coats on new work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 116.52 | 116.52 | 9.72 | False | None | None | False | None | False | 1132.5744 | 0 | 3486410 | 124645 | None | PWD V- 2 SR 2023-24 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 65.7 | 65.7 | 15.3 | False | None | None | False | None | False | 1005.21 | 0 | 3486411 | 124645 | None | PWD V- 2 SR 2023-24 Page No-48 It No-8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 142.55 | 142.55 | 15.3 | False | None | None | False | None | False | 2181.015 | 0 | 3486412 | 124645 | None | PWD V- 2 SR 2023-24 It No-15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 913.57 | 913.57 | 10.41 | False | None | None | False | None | False | 9510.2637 | 0 |
| 1720446191000 | 0 | None | None | Buildings | Water supply & sanitary works -GF | 110561.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3486413 | 124646 | None | PWD V- 2 SR 2023-24 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 113.98 | 113.98 | 4.0 | False | None | None | False | None | False | 455.92 | 0 | 3486414 | 124646 | None | PWD V- 5 SR 2023-24 It No-657 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 152.39 | 152.39 | 10.0 | False | None | None | False | None | False | 1523.9 | 0 | 3486415 | 124646 | None | PWD V- 5 SR 2023-24 It No-647 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 315.94 | 315.94 | 25.0 | False | None | None | False | None | False | 7898.5 | 0 | 3486416 | 124646 | None | PWD V- 2 SR 2023-24 Page No-125 It No-13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 244.08 | 244.08 | 20.0 | False | None | None | False | None | False | 4881.6 | 0 | 3486417 | 124646 | None | PWD V- 2 SR 2023-24 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 110mm diameter ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 360.54 | 360.54 | 25.0 | False | None | None | False | None | False | 9013.5 | 0 | 3486418 | 124646 | None | PWD V- 2 SR 2023-24 Page No-124 It No-13.59 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all
fitting arrangements & all necessary accessories complete ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 272.58 | 272.58 | 4.0 | False | None | None | False | None | False | 1090.32 | 0 | 3486419 | 124646 | None | SR 2018-19 It No-37.28.1 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 162.3 | 162.3 | 6.0 | False | None | None | False | None | False | 973.8 | 0 | 3486420 | 124646 | None | SR 2018-19 It No-37.28.1 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10.00 cms thick ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 194.52 | 194.52 | 5.0 | False | None | None | False | None | False | 972.6 | 0 | 3486421 | 124646 | None | PWD V- 2 SR 2023-24 Page No-123 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 1261.3 | 1261.3 | 1.0 | False | None | None | False | None | False | 1261.3 | 0 | 3486422 | 124646 | None | PWD V- 2 SR 2023-24 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3486423 | 124646 | None | PWD V- 2 SR 2023-24 It No-14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 614.54 | 614.54 | 1.0 | False | None | None | False | None | False | 614.54 | 0 | 3486424 | 124646 | None | PWD V- 2 SR 2023-24 Page No-131 It No-14.2.1 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required : W.C. pan with ISI marked white solid plastic seat and lid ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 13496.42 | 13496.42 | 1.0 | False | None | None | False | None | False | 13496.42 | 0 | 3486425 | 124646 | None | PWD V- 2 SR 2023-24 Page No-123 It No-14.1.1 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 6051.27 | 6051.27 | 1.0 | False | None | None | False | None | False | 6051.27 | 0 | 3486426 | 124646 | None | PWD V- 2 SR 2023-24 Page No-131 It No-14.4.4 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 16193.73 | 16193.73 | 1.0 | False | None | None | False | None | False | 16193.73 | 0 | 3486427 | 124646 | None | PWD V- 2 SR 2021-22 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 6296.59 | 6296.59 | 1.0 | False | None | None | False | None | False | 6296.59 | 0 | 3486428 | 124646 | None | PWD V- 2 SR 2023-24 Page No-124 It No-14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 3818.59 | 3818.59 | 1.0 | False | None | None | False | None | False | 3818.59 | 0 | 3486429 | 124646 | None | PWD V- 2 SR 2023-24 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 469.58 | 469.58 | 20.0 | False | None | None | False | None | False | 9391.6 | 0 | 3486430 | 124646 | None | PWD V- 2 SR 2023-24 Page No-122 It No-13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipes ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 366.74 | 366.74 | 40.0 | False | None | None | False | None | False | 14669.6 | 0 | 3486431 | 124646 | None | PWD V 2 SR 2023-24 163 Pg.No A-16 | Brass bib-cock 15 mm dia ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 557.55 | 557.55 | 2.0 | False | None | None | False | None | False | 1115.1 | 0 | 3486432 | 124646 | None | PWD V- 5 SR 2023-24 Page No-191 It No-16.10 | Constructing brick masonry chamber of internal dimension 450x450mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for
fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 5248.4 | 5248.4 | 2.0 | False | None | None | False | None | False | 10496.8 | 0 |
| 1720446191000 | 0 | None | None | Buildings | Water supply & sanitary works - FF | 111429.22 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3486433 | 124647 | None | PWD V- 2 SR 2023-24 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 114.04 | 114.04 | 3.0 | False | None | None | False | None | False | 342.12 | 0 | 3486434 | 124647 | None | PWD V- 5 SR 2023-24 It No-657 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 152.46 | 152.46 | 10.0 | False | None | None | False | None | False | 1524.6 | 0 | 3486435 | 124647 | None | PWD V- 5 SR 2023-24 It No-647 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 316.09 | 316.09 | 30.0 | False | None | None | False | None | False | 9482.7 | 0 | 3486436 | 124647 | None | PWD V- 2 SR 2023-24 Page No-124 It No-13.59 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all
fitting arrangements & all necessary accessories complete ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 272.71 | 272.71 | 3.0 | False | None | None | False | None | False | 818.13 | 0 | 3486437 | 124647 | None | PWD V- 2 SR 2023-24 Page No-123 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 1261.9 | 1261.9 | 3.0 | False | None | None | False | None | False | 3785.7 | 0 | 3486438 | 124647 | None | PWD V- 2 SR 2023-24 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 345.84 | 345.84 | 2.0 | False | None | None | False | None | False | 691.68 | 0 | 3486439 | 124647 | None | PWD V- 2 SR 2023-24 It No-14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 614.83 | 614.83 | 1.0 | False | None | None | False | None | False | 614.83 | 0 | 3486440 | 124647 | None | PWD V- 2 SR 2023-24 Page No-131 It No-14.2.1 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required : W.C. pan with ISI marked white solid plastic seat and lid ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 13502.85 | 13502.85 | 2.0 | False | None | None | False | None | False | 27005.7 | 0 | 3486441 | 124647 | None | PWD V- 2 SR 2023-24 Page No-123 It No-14.1.1 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 6054.15 | 6054.15 | 1.0 | False | None | None | False | None | False | 6054.15 | 0 | 3486442 | 124647 | None | PWD V- 2 SR 2023-24 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 5989.7 | 5989.7 | 1.0 | False | None | None | False | None | False | 5989.7 | 0 | 3486443 | 124647 | None | PWD V- 2 SR 2023-24 Page No-124 It No-14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 3820.41 | 3820.41 | 1.0 | False | None | None | False | None | False | 3820.41 | 0 | 3486444 | 124647 | None | PWD V- 2 SR 2023-24 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 469.8 | 469.8 | 20.0 | False | None | None | False | None | False | 9396.0 | 0 | 3486445 | 124647 | None | PWD V- 2 SR 2023-24 Page No-122 It No-13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25 mm nominal dia Pipes ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 366.92 | 366.92 | 20.0 | False | None | None | False | None | False | 7338.4 | 0 | 3486446 | 124647 | None | PWD V- 2 SR 2023-24 163 Pg.No A-16 | Brass bib-cock 15 mm dia ---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 557.55 | 557.55 | 2.0 | False | None | None | False | None | False | 1115.1 | 0 | 3486447 | 124647 | None | PWD V- 5 SR 2023-24 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- Complete as per Specification and as directed by the Engineer in-charge of work | l | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 |
| 1720446191000 | 0 | None | None | Buildings | Internal Electrification | 426920.14 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3486448 | 124648 | None | PWD SR V-6 Item No-2.1.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point up to 3Mtr from tapping point to out let via switch ---- Complete as per Specification and as directed by the Engineer in-charge of work | Point | 353.12 | 353.12 | 30.0 | False | None | None | False | None | False | 10593.6 | 0 | 3486449 | 124648 | None | PWD SR V-6 Item No-2.1.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- Complete as per Specification and as directed by the Engineer in-charge of work | Point | 488.17 | 488.17 | 22.0 | False | None | None | False | None | False | 10739.74 | 0 | 3486450 | 124648 | None | PWD SR V-6 Item No-2.1.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- Complete as per Specification and as directed by the Engineer in-charge of work | Point | 706.23 | 706.23 | 16.0 | False | None | None | False | None | False | 11299.68 | 0 | 3486451 | 124648 | None | PWD SR V-6 Item No-3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 1-3Way ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 170.98 | 170.98 | 16.0 | False | None | None | False | None | False | 2735.68 | 0 | 3486452 | 124648 | None | PWD SR V-6 Item No-3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 4-5Way ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 197.0 | 197.0 | 6.0 | False | None | None | False | None | False | 1182.0 | 0 | 3486453 | 124648 | None | PWD SR V-6 Item No-3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 6Way ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 219.3 | 219.3 | 2.0 | False | None | None | False | None | False | 438.6 | 0 | 3486454 | 124648 | None | PWD SR V-6 Item No-3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 8 Way ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 272.58 | 272.58 | 13.0 | False | None | None | False | None | False | 3543.54 | 0 | 3486455 | 124648 | None | PWD SR V-6 Item No-3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, 10-12Way ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 323.38 | 323.38 | 4.0 | False | None | None | False | None | False | 1293.52 | 0 | 3486456 | 124648 | None | PWD SR V-6 Item No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box., 3 Module ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 199.48 | 199.48 | 16.0 | False | None | None | False | None | False | 3191.68 | 0 | 3486457 | 124648 | None | PWD SR V-6 Item No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 216.83 | 216.83 | 6.0 | False | None | None | False | None | False | 1300.98 | 0 | 3486458 | 124648 | None | PWD SR V-6 Item No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 289.93 | 289.93 | 2.0 | False | None | None | False | None | False | 579.86 | 0 | 3486459 | 124648 | None | PWD SR V-6 Item No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 351.88 | 351.88 | 13.0 | False | None | None | False | None | False | 4574.44 | 0 | 3486460 | 124648 | None | PWD SR V-6 Item No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 426.22 | 426.22 | 4.0 | False | None | None | False | None | False | 1704.88 | 0 | 3486461 | 124648 | None | PWD SR V-6 Item No-3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 126.38 | 126.38 | 102.0 | False | None | None | False | None | False | 12890.76 | 0 | 3486462 | 124648 | None | PWD SR V-6 Item No-3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 211.87 | 211.87 | 37.0 | False | None | None | False | None | False | 7839.19 | 0 | 3486463 | 124648 | None | PWD SR V-6 Item No-3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 442.32 | 442.32 | 12.0 | False | None | None | False | None | False | 5307.84 | 0 | 3486464 | 124648 | None | PWD SR V-6 Item No-3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 403.91 | 403.91 | 6.0 | False | None | None | False | None | False | 2423.46 | 0 | 3486465 | 124648 | None | PWD SR V-6 Item No-3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 292.4 | 292.4 | 6.0 | False | None | None | False | None | False | 1754.4 | 0 | 3486466 | 124648 | None | PWD SR V-6 Item No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 304.79 | 304.79 | 2.0 | False | None | None | False | None | False | 609.58 | 0 | 3486467 | 124648 | None | PWD SR V-6 Item No-1.13 | Supplying And Fixing Metal Fan Box with Round Hook. ---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 144.96 | 144.96 | 12.0 | False | None | None | False | None | False | 1739.52 | 0 | 3486468 | 124648 | None | PWD SR V-6 Item No-1.2.1 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 81.77 | 81.77 | 250.0 | False | None | None | False | None | False | 20442.5 | 0 | 3486469 | 124648 | None | PWD SR V-6 Item No-1.2.2 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 96.64 | 96.64 | 200.0 | False | None | None | False | None | False | 19328.0 | 0 | 3486470 | 124648 | None | PWD SR V-6 Item No-1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 84.25 | 84.25 | 120.0 | False | None | None | False | None | False | 10110.0 | 0 | 3486471 | 124648 | None | PWD SR V-6 Item No-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 97.88 | 97.88 | 100.0 | False | None | None | False | None | False | 9788.0 | 0 | 3486472 | 124648 | None | PWD SR V-6 Item No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2 ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 32.21 | 32.21 | 125.0 | False | None | None | False | None | False | 4026.25 | 0 | 3486473 | 124648 | None | PWD SR V-6 Item No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 52.04 | 52.04 | 360.0 | False | None | None | False | None | False | 18734.4 | 0 | 3486474 | 124648 | None | PWD SR V-6 Item No-2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 78.06 | 78.06 | 250.0 | False | None | None | False | None | False | 19515.0 | 0 | 3486475 | 124648 | None | PWD SR V-6 Item No-5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II- Double Door 12 Way SP & N ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3486476 | 124648 | None | PWD SR V-6 Item No-5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 514.19 | 514.19 | 20.0 | False | None | None | False | None | False | 10283.8 | 0 | 3486477 | 124648 | None | PWD SR V-6 Item No-5.20.1 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16-25 A 2 pole ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3486478 | 124648 | None | PWD SR V-6 Item No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 854.91 | 854.91 | 26.0 | False | None | None | False | None | False | 22227.66 | 0 | 3486479 | 124648 | None | PWD SR V-6 Item No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 1096.52 | 1096.52 | 2.0 | False | None | None | False | None | False | 2193.04 | 0 | 3486480 | 124648 | None | PWD SR V-6 Item No-11.11.3 | Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500K ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 184.61 | 184.61 | 5.0 | False | None | None | False | None | False | 923.05 | 0 | 3486481 | 124648 | None | PWD SR V-6 Item No-6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 1848.59 | 1848.59 | 5.0 | False | None | None | False | None | False | 9242.95 | 0 | 3486482 | 124648 | None | PWD SR V-6 Item No-6.3.1 | Supplying capacitor type ceiling fan complete with down rod
blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 3697.18 | 3697.18 | 12.0 | False | None | None | False | None | False | 44366.16 | 0 | 3486483 | 124648 | None | PWD SR V-6 Item No-13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 151.16 | 151.16 | 28.0 | False | None | None | False | None | False | 4232.48 | 0 | 3486484 | 124648 | None | PWD SR V-6 Item No-13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 390.29 | 390.29 | 12.0 | False | None | None | False | None | False | 4683.48 | 0 | 3486485 | 124648 | None | PWD SR V-6 Item No-13.13 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 875.97 | 875.97 | 5.0 | False | None | None | False | None | False | 4379.85 | 0 | 3486486 | 124648 | None | PWD SR V-6 Item No-13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 1810.18 | 1810.18 | 2.0 | False | None | None | False | None | False | 3620.36 | 0 | 3486487 | 124648 | None | PWD SR V-6 Item No-13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 200.72 | 200.72 | 2.0 | False | None | None | False | None | False | 401.44 | 0 | 3486488 | 124648 | None | ESCOM SR 23-24 IT NO: 32.03 Page No: 13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) ---- Complete as per Specification and as directed by the Engineer in-charge of work | Km | 146206.96 | 146206.96 | 0.1 | False | None | None | False | None | False | 14620.696 | 0 | 3486489 | 124648 | None | ESCOM SR 23-24 IT NO: 21.05 Page No: 52 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff
LT Cable 2.5 to 25 Sqmm ---- Complete as per Specification and as directed by the Engineer in-charge of work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3486490 | 124648 | None | PWD ELE 19-20 ITEM NO 6.9 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Mtr | 701.27 | 701.27 | 5.0 | False | None | None | False | None | False | 3506.35 | 0 | 3486491 | 124648 | None | PWD ELE 19-20 ITEM NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 144.96 | 144.96 | 5.0 | False | None | None | False | None | False | 724.8 | 0 | 3486492 | 124648 | None | PWD ELE 19-20 ITEM NO 12.57 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. ---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 5273.18 | 5273.18 | 2.0 | False | None | None | False | None | False | 10546.36 | 0 | 3486493 | 124648 | None | PWD ELE 19-20 ITEM NO 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- Complete as per Specification and as directed by the Engineer in-charge of work | Mtr | 101.6 | 101.6 | 50.0 | False | None | None | False | None | False | 5080.0 | 0 | 3486494 | 124648 | None | PWD SR V-6 Item No-5.42.1 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14 SWG ---- Complete as per Specification and as directed by the Engineer in-charge of work | Sq CM | 0.62 | 0.62 | 48000.0 | False | None | None | False | None | False | 29760.0 | 0 | 3486495 | 124648 | None | PWD SR V-6 Item No-5.40.1 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 3054.14 | 3054.14 | 3.0 | False | None | None | False | None | False | 9162.42 | 0 | 3486496 | 124648 | None | PWD SR V-6 Item No-5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 377.9 | 377.9 | 3.0 | False | None | None | False | None | False | 1133.7 | 0 | 3486497 | 124648 | None | PWD SR V-6 Item No-5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- Complete as per Specification and as directed by the Engineer in-charge of work | m | 936.68 | 936.68 | 3.0 | False | None | None | False | None | False | 2810.04 | 0 | 3486498 | 124648 | None | PWD SR V-6 Item No-5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 1709.82 | 1709.82 | 3.0 | False | None | None | False | None | False | 5129.46 | 0 | 3486499 | 124648 | None | PWD SR V-6 Item No-3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 205.67 | 205.67 | 6.0 | False | None | None | False | None | False | 1234.02 | 0 | 3486500 | 124648 | None | PWD SR V-6 Item No-3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 219.3 | 219.3 | 2.0 | False | None | None | False | None | False | 438.6 | 0 | 3486501 | 124648 | None | PWD SR V-6 Item No-3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 193.28 | 193.28 | 3.0 | False | None | None | False | None | False | 579.84 | 0 | 3486502 | 124648 | None | PWD SR V-6 Item No-11.11.7 | Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500K
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 527.81 | 527.81 | 12.0 | False | None | None | False | None | False | 6333.72 | 0 | 3486503 | 124648 | None | PWD SR V-6 Item No-11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree Nichia Lumileds Osram make LED Source. LED Streetlight 40W ---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3486504 | 124648 | None | PWD SR V-6 Item No-7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 25Litres
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 |
| 1720446191000 | 0 | None | None | Buildings | Septic Tank | 159893.51 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3486505 | 124649 | None | PWD V- 1 SR 2023-24 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 126.38 | 126.38 | 14.53 | False | None | None | False | None | False | 1836.3014 | 0 | 3486506 | 124649 | None | PWD V- 1 SR 2023-24 Page No-15 It No-2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7017.7 | 7017.7 | 1.01 | False | None | None | False | None | False | 7087.877 | 0 | 3486507 | 124649 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Septic tank
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8460.93 | 8460.93 | 0.72 | False | None | None | False | None | False | 6091.8696 | 0 | 3486508 | 124649 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Walls
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11751.3 | 11751.3 | 3.72 | False | None | None | False | None | False | 43714.836 | 0 | 3486509 | 124649 | None | PWD V- 1 SR 2023-24 Page No-16 It No-2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Slab
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 11751.3 | 11751.3 | 0.96 | False | None | None | False | None | False | 11281.248 | 0 | 3486510 | 124649 | None | PWD V- 1 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings
---- Complete as per Specification and as directed by the Engineer in-charge of work | t | 110837.22 | 110837.22 | 0.38 | False | None | None | False | None | False | 42118.1436 | 0 | 3486511 | 124649 | None | PWD V- 1 SR 2023-24 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 329.57 | 329.57 | 7.33 | False | None | None | False | None | False | 2415.7481 | 0 | 3486512 | 124649 | None | PWD V- 2 SR 2023-24 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 365.51 | 365.51 | 32.0 | False | None | None | False | None | False | 11696.32 | 0 | 3486513 | 124649 | None | PWD V- 2 SR 2023-24 It No-15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1012.26 | 1012.26 | 32.0 | False | None | None | False | None | False | 32392.32 | 0 | 3486514 | 124649 | None | PWD V- 2 SR 2023-24 It No-11.45 | KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6
---- Complete as per Specification and as directed by the Engineer in-charge of work | Nos | 314.71 | 314.71 | 4.0 | False | None | None | False | None | False | 1258.84 | 0 |
|
|
---|