createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721715278448
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd39000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-08-2024 17:30:00
tenderQueryClose03-08-2024 17:30:00
technicalBidOpenNone
publishedDate24-07-2024 11:27:52
publishedByPostTP_CO_NYMT
publishedByUserKPE14501 - GANESH RAO P
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonDEVARAJA C
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08188265000
mobileNumber8431919189
tenderSupplierListNone
tenderSchedule
createdTs1721715278488
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT22746
titleCONSTRUCTION OF STORE ROOM AT SAMPIGE NAGARA WATER HOUSE IN NYAMATHI
descriptionCONSTRUCTION OF STORE ROOM AT SAMPIGE NAGARA WATER HOUSE IN NYAMATHI
categoryWORKS
categoryTextWorks
ecv1560000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2299
locationNameDMA Town Panchayat Nyamathi
provisionalAmount1560000.0
groupOverheadTotal279964.33
fileNumberTP/NMT/15TH/2024-25/02
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17217152790000NoneNoneBuildingsCONSTRUCTION OF STORE ROOM AT SAMPIGE NAGARA WATER HOUSE IN NYAMATHI1280035.67
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3588617130509Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum105.06105.0633.3FalseNoneNoneFalseNoneFalse3498.4980
3588618130509Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.6711.01FalseNoneNoneFalseNoneFalse67917.05670
3588619130509Nonecode03Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1267.931267.9322.8FalseNoneNoneFalseNoneFalse28908.8040
3588620130509Nonecode04Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6526.086526.0831.67FalseNoneNoneFalseNoneFalse206680.95360
3588621130509Nonecode05appendix 1 additinalities for form work ,centring and scaffolding revision to 2023-24 vol-1 common SR page no -111 for FootingCum522.09522.094.61FalseNoneNoneFalseNoneFalse2406.83490
3588622130509Nonecode06Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum273.98273.9869.36FalseNoneNoneFalseNoneFalse19003.25280
3588623130509Nonecode07appendix 1 additinalities for form work ,centring and scaffolding revision to 2023-24 vol-1 common SR page no -111 for ColumnCum4568.264568.264.14FalseNoneNoneFalseNoneFalse18912.59640
3588624130509Nonecode08appendix 1 additinalities for form work ,centring and scaffolding revision to 2023-24 vol-1 common SR page no -111 for PBCum3263.043263.043.68FalseNoneNoneFalseNoneFalse12007.98720
3588625130509Nonecode09appendix 1 additinalities for form work ,centring and scaffolding revision to 2023-24 vol-1 common SR page no -111 for RBCum3915.653915.653.85FalseNoneNoneFalseNoneFalse15075.25250
3588626130509Nonecode10appendix 1 additinalities for form work ,centring and scaffolding revision to 2023-24 vol-1 common SR page no -111 for SLABCum3263.043263.0413.39FalseNoneNoneFalseNoneFalse43692.10560
3588627130509Nonecode11appendix 1 additinalities for form work ,centring and scaffolding revision to 2023-24 vol-1 common SR page no -115-116 WEF 01-09-2022 for chejjaCum2936.742936.740.23FalseNoneNoneFalseNoneFalse675.45020
3588628130509Nonecode12Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separatelyTonne92140.7192140.713.1FalseNoneNoneFalseNoneFalse285636.2010
3588629130509Nonecode13Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1267.931267.93122.79FalseNoneNoneFalseNoneFalse155689.12470
3588630130509Nonecode14Providing and constructing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1137.121137.1219.01FalseNoneNoneFalseNoneFalse21616.65120
3588631130509Nonecode15appendix 1 additinalities for form work ,centring and scaffolding revision to 2021-22 vol-1 common SR page no -115-116 WEF 01-09-2022 for LINTELCum3915.653915.651.14FalseNoneNoneFalseNoneFalse4463.8410
3588632130509Nonecode16Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per pecifications and as per directions of Engineer-in-charge.Sqm303.85303.85131.06FalseNoneNoneFalseNoneFalse39822.5810
3588633130509Nonecode17Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing compleSqm364.62364.62159.91FalseNoneNoneFalseNoneFalse58306.38420
3588634130509Nonecode18Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specificationsSqm1433.761433.7640.2FalseNoneNoneFalseNoneFalse57637.1520
3588635130509Nonecode19Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm915.67915.6719.37FalseNoneNoneFalseNoneFalse17736.52790
3588636130509Nonecode20Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm91.6791.67137.11FalseNoneNoneFalseNoneFalse12568.87370
3588637130509Nonecode21Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over cand including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm141.11141.11111.6FalseNoneNoneFalseNoneFalse15747.8760
3588638130509Nonecode22Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primerapplied @ 0.80 ltr/10 m² of approved brand and manufacture includingpreparing the surface after thorougly cleaning oil, grease, dirt and foreignmatter, cost of materials, labour complete as per specifications and asper directions of Engineer-in-charge.Sqm143.17143.176.93FalseNoneNoneFalseNoneFalse992.16810
3588639130509Nonecode23Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Kg152.44152.44130.41FalseNoneNoneFalseNoneFalse19879.70040
3588640130509Nonecode24Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hingesnSqm1635.641635.643.15FalseNoneNoneFalseNoneFalse5152.2660
3588641130509Nonecode25Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-chargeSqm327.54327.5411.4FalseNoneNoneFalseNoneFalse3733.9560
3588642130509Nonecode26Providing and fixing Chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting this includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching,refilling & testing of joinits complete as per direction of engineer in charge .Mtr491.31491.3160.0FalseNoneNoneFalseNoneFalse29478.60
3588643130509Nonecode27Providing and fixing Chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting this includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching,refilling & testing of joinits complete as per direction of engineer in charge . 25 mm Outer dia.Mtr390.37390.3760.0FalseNoneNoneFalseNoneFalse23422.20
3588644130509Nonecode28Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes herever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc .Pipes of SN4, 110mm dia.Mtr275.87275.8760.0FalseNoneNoneFalseNoneFalse16552.20
3588645130509Nonecode29Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls herever require:r: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar tapsNo3174.463174.461.0FalseNoneNoneFalseNoneFalse3174.460
3588646130509Nonecode30Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsNo5030.525030.521.0FalseNoneNoneFalseNoneFalse5030.520
3588647130509Nonecode31providing and fixing C.P. brass bib cock of approved quality conform ing to IS:8931 PWDNo654.05654.052.0FalseNoneNoneFalseNoneFalse1308.10
3588648130509Nonecode32Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931No746.75746.752.0FalseNoneNoneFalseNoneFalse1493.50
3588649130509Nonecode33Providing and placing on terrace Chlorinated polyethylene water storage tank IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet ,outlet and overflow pipes but without fittings and the base support for tank.Ltr9.279.27500.0FalseNoneNoneFalseNoneFalse4635.00
3588650130509Nonecode34Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A( P-2, I-2.1.1, 2.1.2, 2.1.3) Short point upto 3Mtr from tapping point to out let via switchNo285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
3588651130509Nonecode35Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A( P-2, I-2.1.1, 2.1.2, 2.1.3) Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchNo394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
3588652130509Nonecode36Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A( P-2, I-2.1.1, 2.1.2, 2.1.3) Long point above 6Mtr upto 10Mtr from tapping point to out let via switchNo570.0570.04.0FalseNoneNoneFalseNoneFalse2280.00
3588653130509Nonecode37Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 6A One Way SwitchNo102.0102.015.0FalseNoneNoneFalseNoneFalse1530.00
3588654130509Nonecode38Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 6A Three Way socketNo171.0171.05.0FalseNoneNoneFalseNoneFalse855.00
3588655130509Nonecode39Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 16A One Way SwitchNo180.0180.010.0FalseNoneNoneFalseNoneFalse1800.00
3588656130509Nonecode40Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P-5, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.8, 3.6.11 ) 6/16A Universal SocketNo236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3588657130509Nonecode41Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2Mtr26.026.05.0FalseNoneNoneFalseNoneFalse130.00
3588658130509Nonecode42Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mmMtr42.042.090.0FalseNoneNoneFalseNoneFalse3780.00
3588659130509Nonecode43Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mmMtr63.063.090.0FalseNoneNoneFalseNoneFalse5670.00
3588660130509Nonecode44Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 WayNo137.0137.010.0FalseNoneNoneFalseNoneFalse1370.00
3588661130509Nonecode45Supplying & Fixing of 70-150 W lamp holder 2 PinNo63.063.05.0FalseNoneNoneFalseNoneFalse315.00
3588662130509Nonecode46Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thickMtr81.081.090.0FalseNoneNoneFalseNoneFalse7290.00
3588663130509Nonecode47Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230V 50Hz AC supply & completetly wired on existing boxNo646.0646.02.0FalseNoneNoneFalseNoneFalse1292.00
3588664130509Nonecode48Supplying & fixing of 32Amps Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washersNo241.0241.03.0FalseNoneNoneFalseNoneFalse723.00
3588665130509Nonecode49Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63Amps DPNo1102.01102.04.0FalseNoneNoneFalseNoneFalse4408.00
3588666130509Nonecode50Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 160 A 25 kANo13447.013447.01.0FalseNoneNoneFalseNoneFalse13447.00
3588667130509Nonecode51Thermoplastic Modular MCB Distribution box enclosure with transparent polycarbonate lid 1 row 12 Module with hinged flapNo4360.04360.01.0FalseNoneNoneFalseNoneFalse4360.00
3588668130509Nonecode52Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. 1 x 4' Tube light fitting.No340.0340.05.0FalseNoneNoneFalseNoneFalse1700.00
3588669130509Nonecode53Supplying and fixing/replacing of fluorescent tube. 18 to 40WNo95.095.05.0FalseNoneNoneFalseNoneFalse475.00
3588670130509Nonecode54Supplying & fixing retrofit type PL LED Lamp W LED linear source with CCT 6500 degree K, CRI 70 efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the systemNo702.0702.05.0FalseNoneNoneFalseNoneFalse3510.00
3588671130509Nonecode55Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., completeMtr205.0205.025.0FalseNoneNoneFalseNoneFalse5125.00
3588672130509Nonecode56Earthing supplying fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit the pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth . the connections from the pipe to the conduits etc. is established through G I wire of sizes as per clause 7.3.3 of is 732using 12mm bolts nuts and check nuts the pipe shall have 16 through holes of 12mm dia ( P430A)No3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
3588673130509Nonecode57Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in ChargeNo9270.09270.01.0FalseNoneNoneFalseNoneFalse9270.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17217152850000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17217152850000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17217152850000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17217152850000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17217152850000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17217152850000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17217152850000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17217152850000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17217152850000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17217152850000NoneNoneELIGIBILITYBanker DetailsNone
17217153060000NoneNoneELIGIBILITYAS PER BID DOCUMENTNone
17217153510000NoneNoneELIGIBILITYAS PER BID DOCUMENTNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate LAST 3 YEARSTrueTechnical Bid
CONTRACTOR Registration CertificateTrueTechnical Bid
IT returns for past 3 yearsTrueTechnical Bid
GST and PAN Card RegistrationTrueTechnical Bid
SIMILAR WORK DONE CERTIFICATETrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone