tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1720181478000 | 0 | None | None | Buildings | Civil Work-Ground Floor | 3013523.91 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3460854 | 123352 | None | CSR 2023-24 Vol-1, P. no. 8, It. No. 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 126.38 | 126.38 | 115.66 | False | None | None | False | None | False | 14617.1108 | 0 | 3460855 | 123352 | None | CSR 2023-24 Vol-1, P. no. 8, It. No. 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 449.76 | 449.76 | 21.23 | False | None | None | False | None | False | 9548.4048 | 0 | 3460856 | 123352 | None | CSR 2023-24 Vol-1, P. no. 7, It. No. 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 329.57 | 329.57 | 90.63 | False | None | None | False | None | False | 29868.9291 | 0 | 3460857 | 123352 | None | CSR 2023-24 Vol-1, P. no. 7, It. No. 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 587.29 | 587.29 | 23.06 | False | None | None | False | None | False | 13542.9074 | 0 | 3460858 | 123352 | None | CSR 2023-24 Vol-1, P. no. 15, It. No. 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7420.37 | 7420.37 | 13.86 | False | None | None | False | None | False | 102846.3282 | 0 | 3460859 | 123352 | None | CSR 2023-24 Vol-1, P. no. 15, It. No. 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8074.6 | 8074.6 | 22.49 | False | None | None | False | None | False | 181597.754 | 0 | 3460860 | 123352 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 14130.8 | 14130.8 | 5.42 | False | None | None | False | None | False | 76588.936 | 0 | 3460861 | 123352 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
For Plinth Beam
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 12515.85 | 12515.85 | 7.56 | False | None | None | False | None | False | 94619.826 | 0 | 3460862 | 123352 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Lintel Concrete
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 13323.32 | 13323.32 | 2.46 | False | None | None | False | None | False | 32775.3672 | 0 | 3460863 | 123352 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Chajja
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 12112.11 | 12112.11 | 0.9 | False | None | None | False | None | False | 10900.899 | 0 | 3460864 | 123352 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Roof Beam
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 13323.32 | 13323.32 | 7.54 | False | None | None | False | None | False | 100457.8328 | 0 | 3460865 | 123352 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Roof Slab
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 12515.85 | 12515.85 | 14.26 | False | None | None | False | None | False | 178476.021 | 0 | 3460866 | 123352 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Staircase
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 12515.85 | 12515.85 | 1.45 | False | None | None | False | None | False | 18147.9825 | 0 | 3460867 | 123352 | None | CSR 2023-24 Vol-1 P. no. 18, It. No. 2.11 (a) | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | t | 110837.22 | 110837.22 | 5.47 | False | None | None | False | None | False | 606279.5934 | 0 | 3460868 | 123352 | None | Vol-2, P. no. 9, It. No. 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) m- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7915.97 | 7915.97 | 15.66 | False | None | None | False | None | False | 123964.0902 | 0 | 3460869 | 123352 | None | Vol-2, P. no. 14, It. No. 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. CSR 2023-24 Vol-2 P.No. 14 Item No 6.8
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 9873.59 | 9873.59 | 30.43 | False | None | None | False | None | False | 300453.3437 | 0 | 3460870 | 123352 | None | Vol-2, P. no. 14, It. No. 6.15 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1279.89 | 1279.89 | 68.56 | False | None | None | False | None | False | 87749.2584 | 0 | 3460871 | 123352 | None | Vol-2, P. no. 100, It. No. 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 122431.79 | 122431.79 | 0.63 | False | None | None | False | None | False | 77132.0277 | 0 | 3460872 | 123352 | None | Vol-2, P. no. 104, It. No. 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 1258.82 | 1258.82 | 10.0 | False | None | None | False | None | False | 12588.2 | 0 | 3460873 | 123352 | None | Vol-2, P. no. 105, It. No. 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm withnecessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 293.64 | 293.64 | 20.0 | False | None | None | False | None | False | 5872.8 | 0 | 3460874 | 123352 | None | Vol-2, P. no. 105, It. No. 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 161.07 | 161.07 | 12.0 | False | None | None | False | None | False | 1932.84 | 0 | 3460875 | 123352 | None | Vol-2, P. no. 105, It. No. 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 68.15 | 68.15 | 10.0 | False | None | None | False | None | False | 681.5 | 0 | 3460876 | 123352 | None | Vol-2, P. no. 108, It. No. 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. 125x85x5.5 mm (heavy type).
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 340.73 | 340.73 | 42.0 | False | None | None | False | None | False | 14310.66 | 0 | 3460877 | 123352 | None | Vol-2, P. no. 69, It. No. 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. Fastener with threaded dia 12 mm.
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 74.34 | 74.34 | 48.0 | False | None | None | False | None | False | 3568.32 | 0 | 3460878 | 123352 | None | Vol-2, P. no. 105, It. No. 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4115.96 | 4115.96 | 20.4 | False | None | None | False | None | False | 83965.584 | 0 | 3460879 | 123352 | None | Vol-2, P. no. 109, It. No. 12.87 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Common SR 2023-24 Vol-2 P.No. 109 I.No.12.87 ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8116.69 | 8116.69 | 14.4 | False | None | None | False | None | False | 116880.336 | 0 | 3460880 | 123352 | None | Vol-2, P. no. 109, It. No. 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of work | 0.75 Cmtr | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3460881 | 123352 | None | Vol-2, P. no. 86, It. No. 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3460882 | 123352 | None | Vol-2, P. no. 111, It. No. 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 869.78 | 869.78 | 9.9 | False | None | None | False | None | False | 8610.822 | 0 | 3460883 | 123352 | None | Vol-2, P. no. 112, It. No. 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 4317.92 | 4317.92 | 3.15 | False | None | None | False | None | False | 13601.448 | 0 | 3460884 | 123352 | None | Vol-2, P. no. 41, It. No. 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 386.57 | 386.57 | 362.16 | False | None | None | False | None | False | 140000.1912 | 0 | 3460885 | 123352 | None | Vol-2, P. no. 50, It. No. 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 123.9 | 123.9 | 362.16 | False | None | None | False | None | False | 44871.624 | 0 | 3460886 | 123352 | None | Vol-2, P. no. 42, It. No. 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 432.41 | 432.41 | 155.58 | False | None | None | False | None | False | 67274.3478 | 0 | 3460887 | 123352 | None | Vol-2, P. no. 60, It. No. 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. - Size of Tile 600x600 mm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1418.66 | 1418.66 | 117.9 | False | None | None | False | None | False | 167260.014 | 0 | 3460888 | 123352 | None | Vol-2, P. no. 41, It. No. 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 365.51 | 365.51 | 10.5 | False | None | None | False | None | False | 3837.855 | 0 | 3460889 | 123352 | None | Vol-2, P. no. 64, It. No. 9.31 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 2583.32 | 2583.32 | 33.41 | False | None | None | False | None | False | 86308.7212 | 0 | 3460890 | 123352 | None | Vol-2, P. no. 60, It. No. 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1101.47 | 1101.47 | 3.12 | False | None | None | False | None | False | 3436.5864 | 0 | 3460891 | 123352 | None | Vol-2, P. no. 65, It. No. 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1795.31 | 1795.31 | 10.5 | False | None | None | False | None | False | 18850.755 | 0 | 3460892 | 123352 | None | Vol-2, P. no. 61, It. No. 9.14 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 437.37 | 437.37 | 10.5 | False | None | None | False | None | False | 4592.385 | 0 | 3460893 | 123352 | None | Vol-2, P. no. 48, It. No. 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 157.35 | 157.35 | 362.16 | False | None | None | False | None | False | 56985.876 | 0 | 3460894 | 123352 | None | Vol-2, P. no. 46, It. No. 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 193.28 | 193.28 | 155.58 | False | None | None | False | None | False | 30070.5024 | 0 | 3460895 | 123352 | None | Vol-2, P. no. 47, It. No. 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 61.95 | 61.95 | 15.12 | False | None | None | False | None | False | 936.684 | 0 | 3460896 | 123352 | None | Vol-2, P. no. 48, It. No. 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 142.49 | 142.49 | 15.12 | False | None | None | False | None | False | 2154.4488 | 0 | 3460897 | 123352 | None | Vol-2, P. no. 47, It. No. 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 65.67 | 65.67 | 15.51 | False | None | None | False | None | False | 1018.5417 | 0 | 3460898 | 123352 | None | Vol-2, P. no. 49, It. No. 8.47 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 167.27 | 167.27 | 15.51 | False | None | None | False | None | False | 2594.3577 | 0 |
| 1720181478000 | 0 | None | None | Buildings | Civil Work-First Floor | 1527231.69 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3460899 | 123353 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
FF Columns
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 14130.8 | 14130.8 | 3.69 | False | None | None | False | None | False | 52142.652 | 0 | 3460900 | 123353 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Lintel Concrete
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 13323.32 | 13323.32 | 1.99 | False | None | None | False | None | False | 26513.4068 | 0 | 3460901 | 123353 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Chajja
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 12112.11 | 12112.11 | 0.6 | False | None | None | False | None | False | 7267.266 | 0 | 3460902 | 123353 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Roof Beam
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 13323.32 | 13323.32 | 6.42 | False | None | None | False | None | False | 85535.7144 | 0 | 3460903 | 123353 | None | CSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
Roof Slab
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 12515.85 | 12515.85 | 11.04 | False | None | None | False | None | False | 138174.984 | 0 | 3460904 | 123353 | None | CSR 2023-24 Vol-1 P. no. 18, It. No. 2.11 (a) | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | t | 110837.22 | 110837.22 | 2.708 | False | None | None | False | None | False | 300147.19176 | 0 | 3460905 | 123353 | None | Vol-2, P. no. 14, It. No. 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. CSR 2023-24 Vol-2 P.No. 14 Item No 6.8
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 9873.59 | 9873.59 | 28.1 | False | None | None | False | None | False | 277447.879 | 0 | 3460906 | 123353 | None | Vol-2, P. no. 14, It. No. 6.15 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1278.89 | 1278.89 | 14.25 | False | None | None | False | None | False | 18224.1825 | 0 | 3460907 | 123353 | None | Vol-2, P. no. 100, It. No. 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 122431.79 | 122431.79 | 0.24 | False | None | None | False | None | False | 29383.6296 | 0 | 3460908 | 123353 | None | Vol-2, P. no. 104, It. No. 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3460909 | 123353 | None | Vol-2, P. no. 105, It. No. 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm withnecessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3460910 | 123353 | None | Vol-2, P. no. 105, It. No. 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 161.07 | 161.07 | 6.0 | False | None | None | False | None | False | 966.42 | 0 | 3460911 | 123353 | None | Vol-2, P. no. 105, It. No. 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 68.15 | 68.15 | 4.0 | False | None | None | False | None | False | 272.6 | 0 | 3460912 | 123353 | None | Vol-2, P. no. 108, It. No. 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. 125x85x5.5 mm (heavy type).
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 340.73 | 340.73 | 18.0 | False | None | None | False | None | False | 6133.14 | 0 | 3460913 | 123353 | None | Vol-2, P. no. 69, It. No. 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. Fastener with threaded dia 12 mm.
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 74.34 | 74.34 | 24.0 | False | None | None | False | None | False | 1784.16 | 0 | 3460914 | 123353 | None | Vol-2, P. no. 205, It. No. 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 64.43 | 64.43 | 30.7 | False | None | None | False | None | False | 1978.001 | 0 | 3460915 | 123353 | None | Vol-2, P. no. 105, It. No. 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 4115.96 | 4115.96 | 7.2 | False | None | None | False | None | False | 29634.912 | 0 | 3460916 | 123353 | None | Vol-2, P. no. 109, It. No. 12.87 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Common SR 2023-24 Vol-2 P.No. 109 I.No.12.87 ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 8116.69 | 8116.69 | 10.8 | False | None | None | False | None | False | 87660.252 | 0 | 3460917 | 123353 | None | Vol-2, P. no. 109, It. No. 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3460918 | 123353 | None | Vol-2, P. no. 86, It. No. 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 208.15 | 208.15 | 207.36 | False | None | None | False | None | False | 43161.984 | 0 | 3460919 | 123353 | None | Vol-2, P. no. 111, It. No. 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 869.78 | 869.78 | 9.9 | False | None | None | False | None | False | 8610.822 | 0 | 3460920 | 123353 | None | Vol-2, P. no. 112, It. No. 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 4317.92 | 4317.92 | 3.15 | False | None | None | False | None | False | 13601.448 | 0 | 3460921 | 123353 | None | Vol-2, P. no. 41, It. No. 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 386.57 | 386.57 | 212.06 | False | None | None | False | None | False | 81976.0342 | 0 | 3460922 | 123353 | None | Vol-2, P. no. 50, It. No. 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 123.9 | 123.9 | 212.06 | False | None | None | False | None | False | 26274.234 | 0 | 3460923 | 123353 | None | Vol-2, P. no. 42, It. No. 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 432.41 | 432.41 | 172.08 | False | None | None | False | None | False | 74409.1128 | 0 | 3460924 | 123353 | None | Vol-2, P. no. 60, It. No. 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. - Size of Tile 600x600 mm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 1418.66 | 1418.66 | 71.9 | False | None | None | False | None | False | 102001.654 | 0 | 3460925 | 123353 | None | Vol-2, P. no. 41, It. No. 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 365.51 | 365.51 | 11.1 | False | None | None | False | None | False | 4057.161 | 0 | 3460926 | 123353 | None | Vol-2, P. no. 60, It. No. 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1101.47 | 1101.47 | 3.36 | False | None | None | False | None | False | 3700.9392 | 0 | 3460927 | 123353 | None | Vol-2, P. no. 65, It. No. 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 1795.31 | 1795.31 | 10.5 | False | None | None | False | None | False | 18850.755 | 0 | 3460928 | 123353 | None | Vol-2, P. no. 61, It. No. 9.14 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 437.37 | 437.37 | 10.5 | False | None | None | False | None | False | 4592.385 | 0 | 3460929 | 123353 | None | Vol-2, P. no. 48, It. No. 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 157.35 | 157.35 | 212.06 | False | None | None | False | None | False | 33367.641 | 0 | 3460930 | 123353 | None | Vol-2, P. no. 46, It. No. 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 193.28 | 193.28 | 172.08 | False | None | None | False | None | False | 33259.6224 | 0 | 3460931 | 123353 | None | Vol-2, P. no. 47, It. No. 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 61.95 | 61.95 | 11.52 | False | None | None | False | None | False | 713.664 | 0 | 3460932 | 123353 | None | Vol-2, P. no. 48, It. No. 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Sqm | 142.49 | 142.49 | 11.52 | False | None | None | False | None | False | 1641.4848 | 0 | 3460933 | 123353 | None | Vol-2, P. no. 47, It. No. 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 65.67 | 65.67 | 5.41 | False | None | None | False | None | False | 355.2747 | 0 | 3460934 | 123353 | None | Vol-2, P. no. 49, It. No. 8.47 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Cum | 167.27 | 167.27 | 5.41 | False | None | None | False | None | False | 904.9307 | 0 |
| 1720181478000 | 0 | None | None | Buildings | Water Supply and Sanitation | 115604.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3460935 | 123354 | None | CSR 2023-24 Vol-2, P. no. 136, It. No. 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 113.99 | 113.99 | 8.0 | False | None | None | False | None | False | 911.92 | 0 | 3460936 | 123354 | None | CSR 2021-22 Vol-V P.No.113 I.No.10.1.5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.75 mm dia PVC pipe of 6Kgs/Sqm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 272.58 | 272.58 | 20.0 | False | None | None | False | None | False | 5451.6 | 0 | 3460937 | 123354 | None | CSR 2021-22 Vol-V P.No.113 I.No.10.1.7 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.110 mm dia PVC pipe of 6Kgs/Sqm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 509.23 | 509.23 | 25.0 | False | None | None | False | None | False | 12730.75 | 0 | 3460938 | 123354 | None | Vol-2, P. no. 131, It. No. 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix- tures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 5994.28 | 5994.28 | 4.0 | False | None | None | False | None | False | 23977.12 | 0 | 3460939 | 123354 | None | Vol-2, P. no. 134, It. No. 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3460940 | 123354 | None | Vol-2, P. no. 120, It. No. 13.17.1 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 86 mm long
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 195.76 | 195.76 | 4.0 | False | None | None | False | None | False | 783.04 | 0 | 3460941 | 123354 | None | Vol-2, P. no. 132, It. No. 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 3818.6 | 3818.6 | 4.0 | False | None | None | False | None | False | 15274.4 | 0 | 3460942 | 123354 | None | Vol-2, P. no. 122, It. No. 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makinggood the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 469.58 | 469.58 | 20.0 | False | None | None | False | None | False | 9391.6 | 0 | 3460943 | 123354 | None | Vol-2, P. no. 122, It. No. 13.33.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes External work - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 268.86 | 268.86 | 30.0 | False | None | None | False | None | False | 8065.8 | 0 | 3460944 | 123354 | None | Vol-2, P. no. 122, It. No. 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes External work - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 366.74 | 366.74 | 20.0 | False | None | None | False | None | False | 7334.8 | 0 | 3460945 | 123354 | None | CSR 2023-24 Vol-5 P.No. 191, I.No.16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover, CSR 2023-24 Vol-5 P.No. 191, I.No.16.9
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 6757.51 | 6757.51 | 2.0 | False | None | None | False | None | False | 13515.02 | 0 | 3460946 | 123354 | None | CSR 2023-24 Vol-2 P.No. 123, I.No.13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Ltr | 11.15 | 11.15 | 500.0 | False | None | None | False | None | False | 5575.0 | 0 |
| 1720181478000 | 0 | None | None | Buildings | Internal Electrification | 334544.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3460947 | 123355 | None | CSR Vol-6, It.No 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Short point up to 3Mtr from tapping point to out let via switch
---- Complete as per Specification and as directed by the Engineer in-charge of work | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3460948 | 123355 | None | CSR Vol-6 , It.No 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- Complete as per Specification and as directed by the Engineer in-charge of work | Pack | 447.22 | 447.22 | 12.0 | False | None | None | False | None | False | 5366.64 | 0 | 3460949 | 123355 | None | CSR Vol-6, It.No 2.2.3 | Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- Complete as per Specification and as directed by the Engineer in-charge of work | Point | 654.9 | 654.9 | 15.0 | False | None | None | False | None | False | 9823.5 | 0 | 3460950 | 123355 | None | CSR Vol-6, It.No 2.2.4 | Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches
---- Complete as per Specification and as directed by the Engineer in-charge of work | Point | 798.86 | 798.86 | 5.0 | False | None | None | False | None | False | 3994.3 | 0 | 3460951 | 123355 | None | CSR Vol-6, It.No 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-2Way
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 162.84 | 162.84 | 6.0 | False | None | None | False | None | False | 977.04 | 0 | 3460952 | 123355 | None | CSR Vol-6, it.No 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 208.86 | 208.86 | 3.0 | False | None | None | False | None | False | 626.58 | 0 | 3460953 | 123355 | None | V-6, It.No - 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 259.6 | 259.6 | 10.0 | False | None | None | False | None | False | 2596.0 | 0 | 3460954 | 123355 | None | V-6, t.No 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 307.98 | 307.98 | 10.0 | False | None | None | False | None | False | 3079.8 | 0 | 3460955 | 123355 | None | V-6, It.No 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 376.42 | 376.42 | 6.0 | False | None | None | False | None | False | 2258.52 | 0 | 3460956 | 123355 | None | V-6, It.No - 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 161.66 | 161.66 | 6.0 | False | None | None | False | None | False | 969.96 | 0 | 3460957 | 123355 | None | V-6, It.No 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 206.5 | 206.5 | 3.0 | False | None | None | False | None | False | 619.5 | 0 | 3460958 | 123355 | None | V-6, It.No 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 276.12 | 276.12 | 10.0 | False | None | None | False | None | False | 2761.2 | 0 | 3460959 | 123355 | None | V-6, It.No -3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 335.12 | 335.12 | 10.0 | False | None | None | False | None | False | 3351.2 | 0 | 3460960 | 123355 | None | V-6, It.No -3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 405.92 | 405.92 | 6.0 | False | None | None | False | None | False | 2435.52 | 0 | 3460961 | 123355 | None | V-6, It.No 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 120.36 | 120.36 | 60.0 | False | None | None | False | None | False | 7221.6 | 0 | 3460962 | 123355 | None | V-6, It.No 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 201.78 | 201.78 | 30.0 | False | None | None | False | None | False | 6053.4 | 0 | 3460963 | 123355 | None | V-6.It.No 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 421.26 | 421.26 | 12.0 | False | None | None | False | None | False | 5055.12 | 0 | 3460964 | 123355 | None | V-6. It.No 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 212.4 | 212.4 | 2.0 | False | None | None | False | None | False | 424.8 | 0 | 3460965 | 123355 | None | V-6. It.No 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 384.68 | 384.68 | 8.0 | False | None | None | False | None | False | 3077.44 | 0 | 3460966 | 123355 | None | V-6. It.No 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 278.48 | 278.48 | 10.0 | False | None | None | False | None | False | 2784.8 | 0 | 3460967 | 123355 | None | V-6, It.No 1.13 | Supplyin and Fixing Metal Fan Box with Round Hook.
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 138.06 | 138.06 | 12.0 | False | None | None | False | None | False | 1656.72 | 0 | 3460968 | 123355 | None | V-6, It.No 1.1.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 81.42 | 81.42 | 180.0 | False | None | None | False | None | False | 14655.6 | 0 | 3460969 | 123355 | None | V-6, It.No 1.1.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 95.58 | 95.58 | 120.0 | False | None | None | False | None | False | 11469.6 | 0 | 3460970 | 123355 | None | V-6, It.No 1.1.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 125.08 | 125.08 | 30.0 | False | None | None | False | None | False | 3752.4 | 0 | 3460971 | 123355 | None | V-6, It.No 1.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 80.24 | 80.24 | 100.0 | False | None | None | False | None | False | 8024.0 | 0 | 3460972 | 123355 | None | V-6, It.No 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
25mm dia 2mm thick
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 93.22 | 93.22 | 60.0 | False | None | None | False | None | False | 5593.2 | 0 | 3460973 | 123355 | None | V-6, It.No 1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 116.82 | 116.82 | 15.0 | False | None | None | False | None | False | 1752.3 | 0 | 3460974 | 123355 | None | V-6, It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments.
1.5 sqmm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 30.68 | 30.68 | 180.0 | False | None | None | False | None | False | 5522.4 | 0 | 3460975 | 123355 | None | V-6, It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments.
2.5 sqmm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 49.56 | 49.56 | 900.0 | False | None | None | False | None | False | 44604.0 | 0 | 3460976 | 123355 | None | V-6, It.No 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments.
4 sqmm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 74.34 | 74.34 | 300.0 | False | None | None | False | None | False | 22302.0 | 0 | 3460977 | 123355 | None | V-6. It.No 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments."
6 sqmm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Rmtr | 108.56 | 108.56 | 260.0 | False | None | None | False | None | False | 28225.6 | 0 | 3460978 | 123355 | None | V-6. It.No 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
4 Way TPN DB
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 4764.84 | 4764.84 | 1.0 | False | None | None | False | None | False | 4764.84 | 0 | 3460979 | 123355 | None | V-6.It.No 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps SP
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3460980 | 123355 | None | V-6.It.No 5.18.04 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps DP
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 872.02 | 872.02 | 2.0 | False | None | None | False | None | False | 1744.04 | 0 | 3460981 | 123355 | None | Sl.No.203. P.No.13 It.No.BSR-32.07 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
3.5 core 25 sqmm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Km | 164667.82 | 164667.82 | 0.1 | False | None | None | False | None | False | 16466.782 | 0 | 3460982 | 123355 | None | Sl.No.174. P.No.52 It.No.BSR-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
2.5 sqmm to 25 sqmm
---- Complete as per Specification and as directed by the Engineer in-charge of work | Km | 24645.48 | 24645.48 | 0.1 | False | None | None | False | None | False | 2464.548 | 0 | 3460983 | 123355 | None | CSR Vol-6 P.No.54 It.No.12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
---- Complete as per Specification and as directed by the Engineer in-charge of work | No | 5022.08 | 5022.08 | 2.0 | False | None | None | False | None | False | 10044.16 | 0 | 3460984 | 123355 | None | CSR Vol-6 P.No.43 It.No.11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fighting 1 x4'- 20/22 w
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 814.2 | 814.2 | 20.0 | False | None | None | False | None | False | 16284.0 | 0 | 3460985 | 123355 | None | CSR Vol-6 P.No.47 It.No.11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
7 W, 6500K
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 175.82 | 175.82 | 4.0 | False | None | None | False | None | False | 703.28 | 0 | 3460986 | 123355 | None | CSR Vol-6 P.No.47 It.No.61 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 1760.56 | 1760.56 | 4.0 | False | None | None | False | None | False | 7042.24 | 0 | 3460987 | 123355 | None | CSR Vol-6 It.No 6.3 | Supplying capacitor type ceiling fan complete with down rod
blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.
48" Sweep (1200mm) Regular model
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 3521.12 | 3521.12 | 12.0 | False | None | None | False | None | False | 42253.44 | 0 | 3460988 | 123355 | None | CSR Vol-6 It.No 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 143.96 | 143.96 | 34.0 | False | None | None | False | None | False | 4894.64 | 0 | 3460989 | 123355 | None | CSR Vol-6 P.No.57 It.No.13.11 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated
twin twisted copper wire and wiring. ---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 371.7 | 371.7 | 12.0 | False | None | None | False | None | False | 4460.4 | 0 | 3460990 | 123355 | None | CSR Vol-6 P.No.57 It.No.13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- Complete as per Specification and as directed by the Engineer in-charge of work | Each | 834.26 | 834.26 | 4.0 | False | None | None | False | None | False | 3337.04 | 0 |
|
|
---|