createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720418472572
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1250.00
emd99900.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-07-2024 16:30:00
tenderQueryClose26-07-2024 16:00:00
technicalBidOpen31-07-2024 16:31:00
publishedDate23-07-2024 16:24:38
publishedByPostEWHFWD_EE_EEOFF_KLB
publishedByUserKPE14208 - MANIK S KANKATTE
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonKhaja sab
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08472241982
mobileNumber9449843366
tenderSupplierListNone
tenderSchedule
createdTs1720418472601
version7
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT431
titleConstruction of Block Level Public Health Unit in the Premises of TLH at TLH Sedam in Kalaburagi District
descriptionConstruction of Block Level Public Health Unit in the Premises of TLH at TLH Sedam in Kalaburagi District
categoryWORKS
categoryTextWorks
ecv4990904.60
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3525
locationNameEWHFWD Executive Engineer Office Kalburagi
provisionalAmount5000000.0
groupOverheadTotalNone
fileNumberEWHFWD/2023-24/BD/BPHU/SEDAM
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17204184730000NoneNoneBuildingsCIVIL WORKS - GF3013523.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3474845124154NoneCSR 2023-24 Vol-1, P. no. 8, It. No. 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum126.38126.38115.66FalseNoneNoneFalseNoneFalse14617.11080
3474846124154NoneCSR 2023-24 Vol-1, P. no. 8, It. No. 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum449.76449.7621.23FalseNoneNoneFalseNoneFalse9548.40480
3474847124154NoneCSR 2023-24 Vol-1, P. no. 7, It. No. 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum329.57329.5790.63FalseNoneNoneFalseNoneFalse29868.92910
3474848124154NoneCSR 2023-24 Vol-1, P. no. 7, It. No. 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum587.29587.2923.06FalseNoneNoneFalseNoneFalse13542.90740
3474849124154NoneCSR 2023-24 Vol-1, P. no. 15, It. No. 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum7420.377420.3713.86FalseNoneNoneFalseNoneFalse102846.32820
3474850124154NoneCSR 2023-24 Vol-1, P. no. 15, It. No. 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum8074.68074.622.49FalseNoneNoneFalseNoneFalse181597.7540
3474851124154NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum14130.814130.85.42FalseNoneNoneFalseNoneFalse76588.9360
3474852124154NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge For Plinth Beam ---- Complete as per Specification and as directed by the Engineer in-charge of workCum12515.8512515.857.56FalseNoneNoneFalseNoneFalse94619.8260
3474853124154NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Lintel Concrete ---- Complete as per Specification and as directed by the Engineer in-charge of workCum13323.3213323.322.46FalseNoneNoneFalseNoneFalse32775.36720
3474854124154NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Chajja ---- Complete as per Specification and as directed by the Engineer in-charge of workCum12112.1112112.110.9FalseNoneNoneFalseNoneFalse10900.8990
3474855124154NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Roof Beam ---- Complete as per Specification and as directed by the Engineer in-charge of workCum13323.3213323.327.54FalseNoneNoneFalseNoneFalse100457.83280
3474856124154NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Roof Slab ---- Complete as per Specification and as directed by the Engineer in-charge of workCum12515.8512515.8514.26FalseNoneNoneFalseNoneFalse178476.0210
3474857124154NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Staircase ---- Complete as per Specification and as directed by the Engineer in-charge of workCum12515.8512515.851.45FalseNoneNoneFalseNoneFalse18147.98250
3474858124154NoneCSR 2023-24 Vol-1 P. no. 18, It. No. 2.11 (a)Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workt110837.22110837.225.47FalseNoneNoneFalseNoneFalse606279.59340
3474859124154NoneVol-2, P. no. 9, It. No. 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) m- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum7915.977915.9715.66FalseNoneNoneFalseNoneFalse123964.09020
3474860124154NoneVol-2, P. no. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. CSR 2023-24 Vol-2 P.No. 14 Item No 6.8 ---- Complete as per Specification and as directed by the Engineer in-charge of workCum9873.599873.5930.43FalseNoneNoneFalseNoneFalse300453.34370
3474861124154NoneVol-2, P. no. 14, It. No. 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum1279.891279.8968.56FalseNoneNoneFalseNoneFalse87749.25840
3474862124154NoneVol-2, P. no. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum122431.79122431.790.63FalseNoneNoneFalseNoneFalse77132.02770
3474863124154NoneVol-2, P. no. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo1258.821258.8210.0FalseNoneNoneFalseNoneFalse12588.20
3474864124154NoneVol-2, P. no. 105, It. No. 12.62Providing and fixing chromium plated brass handles of 100/125 mm withnecessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo293.64293.6420.0FalseNoneNoneFalseNoneFalse5872.80
3474865124154NoneVol-2, P. no. 105, It. No. 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo161.07161.0712.0FalseNoneNoneFalseNoneFalse1932.840
3474866124154NoneVol-2, P. no. 105, It. No. 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo68.1568.1510.0FalseNoneNoneFalseNoneFalse681.50
3474867124154NoneVol-2, P. no. 108, It. No. 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. 125x85x5.5 mm (heavy type). ---- Complete as per Specification and as directed by the Engineer in-charge of workNo340.73340.7342.0FalseNoneNoneFalseNoneFalse14310.660
3474868124154NoneVol-2, P. no. 69, It. No. 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. Fastener with threaded dia 12 mm. ---- Complete as per Specification and as directed by the Engineer in-charge of workNo74.3474.3448.0FalseNoneNoneFalseNoneFalse3568.320
3474869124154NoneVol-2, P. no. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum4115.964115.9620.4FalseNoneNoneFalseNoneFalse83965.5840
3474870124154NoneVol-2, P. no. 109, It. No. 12.87Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Common SR 2023-24 Vol-2 P.No. 109 I.No.12.87 ---- Complete as per Specification and as directed by the Engineer in-charge of workCum8116.698116.6914.4FalseNoneNoneFalseNoneFalse116880.3360
3474871124154NoneVol-2, P. no. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of work0.75 Cmtr7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3474872124154NoneVol-2, P. no. 86, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3474873124154NoneVol-2, P. no. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr869.78869.789.9FalseNoneNoneFalseNoneFalse8610.8220
3474874124154NoneVol-2, P. no. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm4317.924317.923.15FalseNoneNoneFalseNoneFalse13601.4480
3474875124154NoneVol-2, P. no. 41, It. No. 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum386.57386.57362.16FalseNoneNoneFalseNoneFalse140000.19120
3474876124154NoneVol-2, P. no. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm123.9123.9362.16FalseNoneNoneFalseNoneFalse44871.6240
3474877124154NoneVol-2, P. no. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm432.41432.41155.58FalseNoneNoneFalseNoneFalse67274.34780
3474878124154NoneVol-2, P. no. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. - Size of Tile 600x600 mm ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm1418.661418.66117.9FalseNoneNoneFalseNoneFalse167260.0140
3474879124154NoneVol-2, P. no. 41, It. No. 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm365.51365.5110.5FalseNoneNoneFalseNoneFalse3837.8550
3474880124154NoneVol-2, P. no. 64, It. No. 9.31Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- Complete as per Specification and as directed by the Engineer in-charge of workCum2583.322583.3233.41FalseNoneNoneFalseNoneFalse86308.72120
3474881124154NoneVol-2, P. no. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum1101.471101.473.12FalseNoneNoneFalseNoneFalse3436.58640
3474882124154NoneVol-2, P. no. 65, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum1795.311795.3110.5FalseNoneNoneFalseNoneFalse18850.7550
3474883124154NoneVol-2, P. no. 61, It. No. 9.14Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum437.37437.3710.5FalseNoneNoneFalseNoneFalse4592.3850
3474884124154NoneVol-2, P. no. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm157.35157.35362.16FalseNoneNoneFalseNoneFalse56985.8760
3474885124154NoneVol-2, P. no. 46, It. No. 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum193.28193.28155.58FalseNoneNoneFalseNoneFalse30070.50240
3474886124154NoneVol-2, P. no. 47, It. No. 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum61.9561.9515.12FalseNoneNoneFalseNoneFalse936.6840
3474887124154NoneVol-2, P. no. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm142.49142.4915.12FalseNoneNoneFalseNoneFalse2154.44880
3474888124154NoneVol-2, P. no. 47, It. No. 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum65.6765.6715.51FalseNoneNoneFalseNoneFalse1018.54170
3474889124154NoneVol-2, P. no. 49, It. No. 8.47Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum167.27167.2715.51FalseNoneNoneFalseNoneFalse2594.35770
17204184730000NoneNoneBuildingsCIVIL WORKS - FF1527231.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3474890124155NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge FF Columns ---- Complete as per Specification and as directed by the Engineer in-charge of workCum14130.814130.83.69FalseNoneNoneFalseNoneFalse52142.6520
3474891124155NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Lintel Concrete ---- Complete as per Specification and as directed by the Engineer in-charge of workCum13323.3213323.321.99FalseNoneNoneFalseNoneFalse26513.40680
3474892124155NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Chajja ---- Complete as per Specification and as directed by the Engineer in-charge of workCum12112.1112112.110.6FalseNoneNoneFalseNoneFalse7267.2660
3474893124155NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Roof Beam ---- Complete as per Specification and as directed by the Engineer in-charge of workCum13323.3213323.326.42FalseNoneNoneFalseNoneFalse85535.71440
3474894124155NoneCSR 2023-24 Vol-1, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Roof Slab ---- Complete as per Specification and as directed by the Engineer in-charge of workCum12515.8512515.8511.04FalseNoneNoneFalseNoneFalse138174.9840
3474895124155NoneCSR 2023-24 Vol-1 P. no. 18, It. No. 2.11 (a)Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workt110837.22110837.222.708FalseNoneNoneFalseNoneFalse300147.191760
3474896124155NoneVol-2, P. no. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. CSR 2023-24 Vol-2 P.No. 14 Item No 6.8 ---- Complete as per Specification and as directed by the Engineer in-charge of workCum9873.599873.5928.1FalseNoneNoneFalseNoneFalse277447.8790
3474897124155NoneVol-2, P. no. 14, It. No. 6.15Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum1278.891278.8914.25FalseNoneNoneFalseNoneFalse18224.18250
3474898124155NoneVol-2, P. no. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum122431.79122431.790.24FalseNoneNoneFalseNoneFalse29383.62960
3474899124155NoneVol-2, P. no. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3474900124155NoneVol-2, P. no. 105, It. No. 12.62Providing and fixing chromium plated brass handles of 100/125 mm withnecessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3474901124155NoneVol-2, P. no. 105, It. No. 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo161.07161.076.0FalseNoneNoneFalseNoneFalse966.420
3474902124155NoneVol-2, P. no. 105, It. No. 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo68.1568.154.0FalseNoneNoneFalseNoneFalse272.60
3474903124155NoneVol-2, P. no. 108, It. No. 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. 125x85x5.5 mm (heavy type). ---- Complete as per Specification and as directed by the Engineer in-charge of workNo340.73340.7318.0FalseNoneNoneFalseNoneFalse6133.140
3474904124155NoneVol-2, P. no. 69, It. No. 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge. Fastener with threaded dia 12 mm. ---- Complete as per Specification and as directed by the Engineer in-charge of workNo74.3474.3424.0FalseNoneNoneFalseNoneFalse1784.160
3474905124155NoneVol-2, P. no. 205, It. No. 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr64.4364.4330.7FalseNoneNoneFalseNoneFalse1978.0010
3474906124155NoneVol-2, P. no. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum4115.964115.967.2FalseNoneNoneFalseNoneFalse29634.9120
3474907124155NoneVol-2, P. no. 109, It. No. 12.87Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Common SR 2023-24 Vol-2 P.No. 109 I.No.12.87 ---- Complete as per Specification and as directed by the Engineer in-charge of workCum8116.698116.6910.8FalseNoneNoneFalseNoneFalse87660.2520
3474908124155NoneVol-2, P. no. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3474909124155NoneVol-2, P. no. 86, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum208.15208.15207.36FalseNoneNoneFalseNoneFalse43161.9840
3474910124155NoneVol-2, P. no. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr869.78869.789.9FalseNoneNoneFalseNoneFalse8610.8220
3474911124155NoneVol-2, P. no. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm4317.924317.923.15FalseNoneNoneFalseNoneFalse13601.4480
3474912124155NoneVol-2, P. no. 41, It. No. 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum386.57386.57212.06FalseNoneNoneFalseNoneFalse81976.03420
3474913124155NoneVol-2, P. no. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm123.9123.9212.06FalseNoneNoneFalseNoneFalse26274.2340
3474914124155NoneVol-2, P. no. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm432.41432.41172.08FalseNoneNoneFalseNoneFalse74409.11280
3474915124155NoneVol-2, P. no. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. - Size of Tile 600x600 mm ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm1418.661418.6671.9FalseNoneNoneFalseNoneFalse102001.6540
3474916124155NoneVol-2, P. no. 41, It. No. 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm365.51365.5111.1FalseNoneNoneFalseNoneFalse4057.1610
3474917124155NoneVol-2, P. no. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum1101.471101.473.36FalseNoneNoneFalseNoneFalse3700.93920
3474918124155NoneVol-2, P. no. 65, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.- - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum1795.311795.3110.5FalseNoneNoneFalseNoneFalse18850.7550
3474919124155NoneVol-2, P. no. 61, It. No. 9.14Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum437.37437.3710.5FalseNoneNoneFalseNoneFalse4592.3850
3474920124155NoneVol-2, P. no. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm157.35157.35212.06FalseNoneNoneFalseNoneFalse33367.6410
3474921124155NoneVol-2, P. no. 46, It. No. 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum193.28193.28172.08FalseNoneNoneFalseNoneFalse33259.62240
3474922124155NoneVol-2, P. no. 47, It. No. 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum61.9561.9511.52FalseNoneNoneFalseNoneFalse713.6640
3474923124155NoneVol-2, P. no. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workSqm142.49142.4911.52FalseNoneNoneFalseNoneFalse1641.48480
3474924124155NoneVol-2, P. no. 47, It. No. 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum65.6765.675.41FalseNoneNoneFalseNoneFalse355.27470
3474925124155NoneVol-2, P. no. 49, It. No. 8.47Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workCum167.27167.275.41FalseNoneNoneFalseNoneFalse904.93070
17204184730000NoneNoneBuildingsWATER SUPPLY & SANITARY115604.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3474926124156NoneCSR 2023-24 Vol-2, P. no. 136, It. No. 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr113.99113.998.0FalseNoneNoneFalseNoneFalse911.920
3474927124156NoneCSR 2021-22 Vol-V P.No.113 I.No.10.1.5Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.75 mm dia PVC pipe of 6Kgs/Sqm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr272.58272.5820.0FalseNoneNoneFalseNoneFalse5451.60
3474928124156NoneCSR 2021-22 Vol-V P.No.113 I.No.10.1.7Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.110 mm dia PVC pipe of 6Kgs/Sqm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr509.23509.2325.0FalseNoneNoneFalseNoneFalse12730.750
3474929124156NoneVol-2, P. no. 131, It. No. 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix- tures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- Complete as per Specification and as directed by the Engineer in-charge of workNo5994.285994.284.0FalseNoneNoneFalseNoneFalse23977.120
3474930124156NoneVol-2, P. no. 134, It. No. 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3474931124156NoneVol-2, P. no. 120, It. No. 13.17.1Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 86 mm long, weighing not less than 86 mm long ---- Complete as per Specification and as directed by the Engineer in-charge of workNo195.76195.764.0FalseNoneNoneFalseNoneFalse783.040
3474932124156NoneVol-2, P. no. 132, It. No. 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workNo3818.63818.64.0FalseNoneNoneFalseNoneFalse15274.40
3474933124156NoneVol-2, P. no. 122, It. No. 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and makinggood the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr469.58469.5820.0FalseNoneNoneFalseNoneFalse9391.60
3474934124156NoneVol-2, P. no. 122, It. No. 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes External work - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr268.86268.8630.0FalseNoneNoneFalseNoneFalse8065.80
3474935124156NoneVol-2, P. no. 122, It. No. 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes External work - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr366.74366.7420.0FalseNoneNoneFalseNoneFalse7334.80
3474936124156NoneCSR 2023-24 Vol-5 P.No. 191, I.No.16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover, CSR 2023-24 Vol-5 P.No. 191, I.No.16.9 ---- Complete as per Specification and as directed by the Engineer in-charge of workNo6757.516757.512.0FalseNoneNoneFalseNoneFalse13515.020
3474937124156NoneCSR 2023-24 Vol-2 P.No. 123, I.No.13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- Complete as per Specification and as directed by the Engineer in-charge of workLtr11.1511.15500.0FalseNoneNoneFalseNoneFalse5575.00
17204184730000NoneNoneBuildingsINTERNAL ELECTRICAL334544.75
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3474938124157NoneCSR Vol-6, It.No 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- Complete as per Specification and as directed by the Engineer in-charge of workPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3474939124157NoneCSR Vol-6 , It.No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- Complete as per Specification and as directed by the Engineer in-charge of workPack447.22447.2212.0FalseNoneNoneFalseNoneFalse5366.640
3474940124157NoneCSR Vol-6, It.No 2.2.3Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- Complete as per Specification and as directed by the Engineer in-charge of workPoint654.9654.915.0FalseNoneNoneFalseNoneFalse9823.50
3474941124157NoneCSR Vol-6, It.No 2.2.4Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- Complete as per Specification and as directed by the Engineer in-charge of workPoint798.86798.865.0FalseNoneNoneFalseNoneFalse3994.30
3474942124157NoneCSR Vol-6, It.No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- Complete as per Specification and as directed by the Engineer in-charge of workEach162.84162.846.0FalseNoneNoneFalseNoneFalse977.040
3474943124157NoneCSR Vol-6, it.No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- Complete as per Specification and as directed by the Engineer in-charge of workEach208.86208.863.0FalseNoneNoneFalseNoneFalse626.580
3474944124157NoneV-6, It.No - 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- Complete as per Specification and as directed by the Engineer in-charge of workEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3474945124157NoneV-6, t.No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- Complete as per Specification and as directed by the Engineer in-charge of workEach307.98307.9810.0FalseNoneNoneFalseNoneFalse3079.80
3474946124157NoneV-6, It.No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- Complete as per Specification and as directed by the Engineer in-charge of workEach376.42376.426.0FalseNoneNoneFalseNoneFalse2258.520
3474947124157NoneV-6, It.No - 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- Complete as per Specification and as directed by the Engineer in-charge of workEach161.66161.666.0FalseNoneNoneFalseNoneFalse969.960
3474948124157NoneV-6, It.No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- Complete as per Specification and as directed by the Engineer in-charge of workEach206.5206.53.0FalseNoneNoneFalseNoneFalse619.50
3474949124157NoneV-6, It.No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- Complete as per Specification and as directed by the Engineer in-charge of workEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3474950124157NoneV-6, It.No -3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- Complete as per Specification and as directed by the Engineer in-charge of workEach335.12335.1210.0FalseNoneNoneFalseNoneFalse3351.20
3474951124157NoneV-6, It.No -3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- Complete as per Specification and as directed by the Engineer in-charge of workEach405.92405.926.0FalseNoneNoneFalseNoneFalse2435.520
3474952124157NoneV-6, It.No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- Complete as per Specification and as directed by the Engineer in-charge of workEach120.36120.3660.0FalseNoneNoneFalseNoneFalse7221.60
3474953124157NoneV-6, It.No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- Complete as per Specification and as directed by the Engineer in-charge of workEach201.78201.7830.0FalseNoneNoneFalseNoneFalse6053.40
3474954124157NoneV-6.It.No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- Complete as per Specification and as directed by the Engineer in-charge of workEach421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3474955124157NoneV-6. It.No 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- Complete as per Specification and as directed by the Engineer in-charge of workEach212.4212.42.0FalseNoneNoneFalseNoneFalse424.80
3474956124157NoneV-6. It.No 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- Complete as per Specification and as directed by the Engineer in-charge of workEach384.68384.688.0FalseNoneNoneFalseNoneFalse3077.440
3474957124157NoneV-6. It.No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- Complete as per Specification and as directed by the Engineer in-charge of workEach278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3474958124157NoneV-6, It.No 1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- Complete as per Specification and as directed by the Engineer in-charge of workNo138.06138.0612.0FalseNoneNoneFalseNoneFalse1656.720
3474959124157NoneV-6, It.No 1.1.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr81.4281.42180.0FalseNoneNoneFalseNoneFalse14655.60
3474960124157NoneV-6, It.No 1.1.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr95.5895.58120.0FalseNoneNoneFalseNoneFalse11469.60
3474961124157NoneV-6, It.No 1.1.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr125.08125.0830.0FalseNoneNoneFalseNoneFalse3752.40
3474962124157NoneV-6, It.No 1.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr80.2480.24100.0FalseNoneNoneFalseNoneFalse8024.00
3474963124157NoneV-6, It.No 1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr93.2293.2260.0FalseNoneNoneFalseNoneFalse5593.20
3474964124157NoneV-6, It.No 1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr116.82116.8215.0FalseNoneNoneFalseNoneFalse1752.30
3474965124157NoneV-6, It.No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3474966124157NoneV-6, It.No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr49.5649.56900.0FalseNoneNoneFalseNoneFalse44604.00
3474967124157NoneV-6, It.No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr74.3474.34300.0FalseNoneNoneFalseNoneFalse22302.00
3474968124157NoneV-6. It.No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments." 6 sqmm ---- Complete as per Specification and as directed by the Engineer in-charge of workRmtr108.56108.56260.0FalseNoneNoneFalseNoneFalse28225.60
3474969124157NoneV-6. It.No 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure 4 Way TPN DB ---- Complete as per Specification and as directed by the Engineer in-charge of workEach4764.844764.841.0FalseNoneNoneFalseNoneFalse4764.840
3474970124157NoneV-6.It.No 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- Complete as per Specification and as directed by the Engineer in-charge of workEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3474971124157NoneV-6.It.No 5.18.04Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- Complete as per Specification and as directed by the Engineer in-charge of workEach872.02872.022.0FalseNoneNoneFalseNoneFalse1744.040
3474972124157NoneSl.No.203. P.No.13 It.No.BSR-32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- Complete as per Specification and as directed by the Engineer in-charge of workKm164667.82164667.820.1FalseNoneNoneFalseNoneFalse16466.7820
3474973124157NoneSl.No.174. P.No.52 It.No.BSR-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- Complete as per Specification and as directed by the Engineer in-charge of workKm24645.4824645.480.1FalseNoneNoneFalseNoneFalse2464.5480
3474974124157NoneCSR Vol-6 P.No.54 It.No.12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- Complete as per Specification and as directed by the Engineer in-charge of workNo5022.085022.082.0FalseNoneNoneFalseNoneFalse10044.160
3474975124157NoneCSR Vol-6 P.No.43 It.No.11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- Complete as per Specification and as directed by the Engineer in-charge of workEach814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3474976124157NoneCSR Vol-6 P.No.47 It.No.11.11.3Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- Complete as per Specification and as directed by the Engineer in-charge of workEach175.82175.824.0FalseNoneNoneFalseNoneFalse703.280
3474977124157NoneCSR Vol-6 P.No.47 It.No.61Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- Complete as per Specification and as directed by the Engineer in-charge of workEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3474978124157NoneCSR Vol-6 It.No 6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- Complete as per Specification and as directed by the Engineer in-charge of workEach3521.123521.1212.0FalseNoneNoneFalseNoneFalse42253.440
3474979124157NoneCSR Vol-6 It.No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- Complete as per Specification and as directed by the Engineer in-charge of workEach143.96143.9634.0FalseNoneNoneFalseNoneFalse4894.640
3474980124157NoneCSR Vol-6 P.No.57 It.No.13.11Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- Complete as per Specification and as directed by the Engineer in-charge of workEach371.7371.712.0FalseNoneNoneFalseNoneFalse4460.40
3474981124157NoneCSR Vol-6 P.No.57 It.No.13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- Complete as per Specification and as directed by the Engineer in-charge of workEach834.26834.264.0FalseNoneNoneFalseNoneFalse3337.040
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17204184740000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17204184740000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17204184740001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17204184740000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17204184740000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17204185170000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17204185220000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17204185270000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17204185310000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17204185360000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17204185430000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 90 days beyond the validity of the tender.None
17204185650000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17204185740000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17204185830000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17204185910000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17204186020000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17204186060000NoneNoneELIGIBILITYMaterials like, steel, cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should got tested positive by the quality control authority before use on the work.None
17204186140000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22,2022-23 and 2023-24.None
17204186190000NoneNoneELIGIBILITYThe Defects Liability Period is 1 (one) year from the date of completion of the work including Maintenance.None
17204186250000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within Three days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17204186300000NoneNoneELIGIBILITYRefer Special Instructions to tenderers in bid document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneSatisfactorily completed as prime contractor, at least one similar nature of work of value not less than of Rs.24.96 Lakhs (50% of the cost of the work).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works issued by KPWD/Government Electrical Inspectorate and should have executed similar building electrical works totaling Rs.1.68 Lakhs in any one financial yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs. 0.58 Lakhs in any one financial yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneachieved in at least Two financial year a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 49.91 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity( AXNX2.5 - B )where A Maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 (updated to 2023-24 price level) taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023-24 price level, of existing commitments and on-going works to be completed during the next 5 months (period of completion of the works for which Tenders are invited) Note: (1)The statements showing the value of existing commitments and on-going works as well as the Stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.OthersBid Capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bid Capacity
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work.Sl. No. Position Qualification No. of persons 1 Site Engineer (Civil) B.E. Civil with minimum experience of 7 years in the Construction of buildings or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) 2 Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (Two)OthersTechnical Staff
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical Staff
NoneNoneNoneNoneClass-III & above Registration Certificate issued from competent authority.OthersRegistration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration certificate issued by Competent AuthorityTrueTechnical Bid
Annual Turnover Certificate & balance sheets certified by Chartered AccountantTrueTechnical Bid
Workdone certificate issued by the Officer not below the rank of Executive EngineerTrueTechnical Bid
Tenderer should have latest GST Registration, PAN Card and latest 3 GST clearance certificate in their nameTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone