tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721810360000 | 0 | None | None | Buildings | Construction of primary health centre at nilogal, in kushtagi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600912 | 131059 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3600913 | 131059 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3600914 | 131059 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3600915 | 131059 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3600916 | 131059 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3600917 | 131059 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3600918 | 131059 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3600919 | 131059 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3600920 | 131059 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3600921 | 131059 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3600922 | 131059 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3600923 | 131059 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3600924 | 131059 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3600925 | 131059 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3600926 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3600927 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3600928 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3600929 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3600930 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3600931 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3600932 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3600933 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3600934 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3600935 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3600936 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3600937 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3600938 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3600939 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3600940 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3600941 | 131059 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3600942 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3600943 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3600944 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3600945 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3600946 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3600947 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3600948 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3600949 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3600950 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3600951 | 131059 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3600952 | 131059 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3600953 | 131059 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3600954 | 131059 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3600955 | 131059 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3600956 | 131059 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3600957 | 131059 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3600958 | 131059 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3600959 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3600960 | 131059 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3600961 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3600962 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3600963 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3600964 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3600965 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3600966 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3600967 | 131059 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3600968 | 131059 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3600969 | 131059 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3600970 | 131059 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3600971 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3600972 | 131059 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3600973 | 131059 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3600974 | 131059 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3600975 | 131059 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3600976 | 131059 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3600977 | 131059 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3600978 | 131059 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3600979 | 131059 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3600980 | 131059 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3600981 | 131059 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3600982 | 131059 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3600983 | 131059 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3600984 | 131059 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3600985 | 131059 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3600986 | 131059 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3600987 | 131059 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3600988 | 131059 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3600989 | 131059 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3600990 | 131059 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3600991 | 131059 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3600992 | 131059 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3600993 | 131059 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3600994 | 131059 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3600995 | 131059 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3600996 | 131059 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3600997 | 131059 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3600998 | 131059 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3600999 | 131059 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3601000 | 131059 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3601001 | 131059 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3601002 | 131059 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3601003 | 131059 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3601004 | 131059 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3601005 | 131059 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3601006 | 131059 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3601007 | 131059 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3601008 | 131059 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3601009 | 131059 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3601010 | 131059 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3601011 | 131059 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3601012 | 131059 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3601013 | 131059 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3601014 | 131059 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3601015 | 131059 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3601016 | 131059 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3601017 | 131059 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3601018 | 131059 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3601019 | 131059 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3601020 | 131059 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3601021 | 131059 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3601022 | 131059 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3601023 | 131059 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3601024 | 131059 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3601025 | 131059 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3601026 | 131059 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3601027 | 131059 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3601028 | 131059 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3601029 | 131059 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3601030 | 131059 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3601031 | 131059 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3601032 | 131059 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3601033 | 131059 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3601034 | 131059 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3601035 | 131059 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3601036 | 131059 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3601037 | 131059 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3601038 | 131059 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3601039 | 131059 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3601040 | 131059 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3601041 | 131059 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3601042 | 131059 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3601043 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3601044 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3601045 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3601046 | 131059 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3601047 | 131059 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3601048 | 131059 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3601049 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3601050 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3601051 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3601052 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3601053 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3601054 | 131059 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3601055 | 131059 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3601056 | 131059 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3601057 | 131059 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3601058 | 131059 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3601059 | 131059 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3601060 | 131059 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3601061 | 131059 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3601062 | 131059 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3601063 | 131059 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3601064 | 131059 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3601065 | 131059 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3601066 | 131059 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3601067 | 131059 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3601068 | 131059 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3601069 | 131059 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3601070 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3601071 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3601072 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3601073 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3601074 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3601075 | 131059 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3601076 | 131059 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3601077 | 131059 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3601078 | 131059 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3601079 | 131059 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3601080 | 131059 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3601081 | 131059 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3601082 | 131059 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3601083 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3601084 | 131059 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3601085 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3601086 | 131059 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3601087 | 131059 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3601088 | 131059 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3601089 | 131059 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3601090 | 131059 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3601091 | 131059 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3601092 | 131059 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3601093 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3601094 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3601095 | 131059 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3601096 | 131059 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3601097 | 131059 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3601098 | 131059 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3601099 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3601100 | 131059 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3601101 | 131059 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3601102 | 131059 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3601103 | 131059 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3601104 | 131059 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3601105 | 131059 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3601106 | 131059 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3601107 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3601108 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3601109 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3601110 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3601111 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3601112 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3601113 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3601114 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3601115 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3601116 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3601117 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3601118 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3601119 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3601120 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3601121 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3601122 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3601123 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3601124 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3601125 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3601126 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3601127 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3601128 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3601129 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3601130 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3601131 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3601132 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3601133 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3601134 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3601135 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3601136 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3601137 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3601138 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3601139 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3601140 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3601141 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3601142 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3601143 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3601144 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3601145 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3601146 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3601147 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3601148 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3601149 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3601150 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3601151 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3601152 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3601153 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3601154 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3601155 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3601156 | 131059 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3601157 | 131059 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3601158 | 131059 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3601159 | 131059 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3601160 | 131059 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3601161 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3601162 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3601163 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3601164 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3601165 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3601166 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3601167 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3601168 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3601169 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3601170 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3601171 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3601172 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3601173 | 131059 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3601174 | 131059 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3601175 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3601176 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3601177 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3601178 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3601179 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3601180 | 131059 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3601181 | 131059 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3601182 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3601183 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3601184 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3601185 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3601186 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3601187 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3601188 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3601189 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3601190 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3601191 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3601192 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3601193 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3601194 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3601195 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3601196 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3601197 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3601198 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3601199 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3601200 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3601201 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3601202 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3601203 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3601204 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3601205 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3601206 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3601207 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3601208 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3601209 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3601210 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3601211 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3601212 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3601213 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3601214 | 131059 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3601215 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3601216 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3601217 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3601218 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3601219 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3601220 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3601221 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3601222 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3601223 | 131059 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3601224 | 131059 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3601225 | 131059 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3601226 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3601227 | 131059 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3601228 | 131059 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3601229 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3601230 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3601231 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3601232 | 131059 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3601233 | 131059 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3601234 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3601235 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3601236 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3601237 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3601238 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3601239 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3601240 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3601241 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3601242 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3601243 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3601244 | 131059 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3601245 | 131059 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3601246 | 131059 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3601247 | 131059 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3601248 | 131059 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3601249 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3601250 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3601251 | 131059 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3601252 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3601253 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3601254 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3601255 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3601256 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3601257 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3601258 | 131059 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3601259 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3601260 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3601261 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3601262 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3601263 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3601264 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3601265 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3601266 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3601267 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3601268 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3601269 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3601270 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3601271 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3601272 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3601273 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3601274 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3601275 | 131059 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3601276 | 131059 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3601277 | 131059 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3601278 | 131059 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3601279 | 131059 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3601280 | 131059 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3601281 | 131059 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3601282 | 131059 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3601283 | 131059 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3601284 | 131059 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3601285 | 131059 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3601286 | 131059 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3601287 | 131059 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3601288 | 131059 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3601289 | 131059 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3601290 | 131059 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3601291 | 131059 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3601292 | 131059 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3601293 | 131059 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3601294 | 131059 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3601295 | 131059 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3601296 | 131059 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3601297 | 131059 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3601298 | 131059 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3601299 | 131059 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3601300 | 131059 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3601301 | 131059 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3601302 | 131059 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3601303 | 131059 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3601304 | 131059 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3601305 | 131059 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3601306 | 131059 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3601307 | 131059 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3601308 | 131059 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3601309 | 131059 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3601310 | 131059 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3601311 | 131059 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3601312 | 131059 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3601313 | 131059 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3601314 | 131059 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3601315 | 131059 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3601316 | 131059 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3601317 | 131059 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3601318 | 131059 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3601319 | 131059 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3601320 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3601321 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3601322 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3601323 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3601324 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3601325 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3601326 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3601327 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3601328 | 131059 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3601329 | 131059 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3601330 | 131059 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3601331 | 131059 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3601332 | 131059 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3601333 | 131059 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3601334 | 131059 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3601335 | 131059 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3601336 | 131059 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3601337 | 131059 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3601338 | 131059 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3601339 | 131059 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3601340 | 131059 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3601341 | 131059 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3601342 | 131059 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3601343 | 131059 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3601344 | 131059 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3601345 | 131059 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3601346 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3601347 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3601348 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3601349 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3601350 | 131059 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3601351 | 131059 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3601352 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3601353 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3601354 | 131059 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3601355 | 131059 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3601356 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3601357 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3601358 | 131059 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3601359 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3601360 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3601361 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3601362 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3601363 | 131059 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3601364 | 131059 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3601365 | 131059 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3601366 | 131059 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3601367 | 131059 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3601368 | 131059 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3601369 | 131059 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3601370 | 131059 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3601371 | 131059 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3601372 | 131059 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3601373 | 131059 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3601374 | 131059 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3601375 | 131059 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3601376 | 131059 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3601377 | 131059 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3601378 | 131059 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3601379 | 131059 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3601380 | 131059 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3601381 | 131059 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3601382 | 131059 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3601383 | 131059 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3601384 | 131059 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3601385 | 131059 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3601386 | 131059 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3601387 | 131059 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3601388 | 131059 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3601389 | 131059 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3601390 | 131059 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3601391 | 131059 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3601392 | 131059 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3601393 | 131059 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3601394 | 131059 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3601395 | 131059 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3601396 | 131059 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3601397 | 131059 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3601398 | 131059 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3601399 | 131059 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3601400 | 131059 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3601401 | 131059 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3601402 | 131059 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3601403 | 131059 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3601404 | 131059 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3601405 | 131059 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3601406 | 131059 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3601407 | 131059 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3601408 | 131059 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3601409 | 131059 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3601410 | 131059 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3601411 | 131059 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3601412 | 131059 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3601413 | 131059 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3601414 | 131059 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3601415 | 131059 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3601416 | 131059 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3601417 | 131059 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3601418 | 131059 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3601419 | 131059 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3601420 | 131059 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3601421 | 131059 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3601422 | 131059 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3601423 | 131059 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3601424 | 131059 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3601425 | 131059 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3601426 | 131059 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3601427 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3601428 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3601429 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3601430 | 131059 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3601431 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3601432 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3601433 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3601434 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3601435 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3601436 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3601437 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3601438 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3601439 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3601440 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3601441 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3601442 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3601443 | 131059 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3601444 | 131059 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3601445 | 131059 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3601446 | 131059 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3601447 | 131059 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3601448 | 131059 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3601449 | 131059 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3601450 | 131059 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3601451 | 131059 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3601452 | 131059 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3601453 | 131059 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3601454 | 131059 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3601455 | 131059 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3601456 | 131059 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3601457 | 131059 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3601458 | 131059 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3601459 | 131059 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3601460 | 131059 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3601461 | 131059 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3601462 | 131059 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3601463 | 131059 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3601464 | 131059 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3601465 | 131059 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3601466 | 131059 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3601467 | 131059 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3601468 | 131059 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3601469 | 131059 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3601470 | 131059 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3601471 | 131059 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3601472 | 131059 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3601473 | 131059 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3601474 | 131059 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3601475 | 131059 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3601476 | 131059 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3601477 | 131059 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3601478 | 131059 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3601479 | 131059 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3601480 | 131059 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3601481 | 131059 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3601482 | 131059 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3601483 | 131059 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3601484 | 131059 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3601485 | 131059 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3601486 | 131059 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3601487 | 131059 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3601488 | 131059 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3601489 | 131059 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3601490 | 131059 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3601491 | 131059 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3601492 | 131059 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3601493 | 131059 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3601494 | 131059 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3601495 | 131059 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3601496 | 131059 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3601497 | 131059 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3601498 | 131059 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3601499 | 131059 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3601500 | 131059 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3601501 | 131059 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3601502 | 131059 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3601503 | 131059 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3601504 | 131059 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3601505 | 131059 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3601506 | 131059 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3601507 | 131059 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3601508 | 131059 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3601509 | 131059 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3601510 | 131059 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3601511 | 131059 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3601512 | 131059 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3601513 | 131059 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3601514 | 131059 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3601515 | 131059 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3601516 | 131059 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3601517 | 131059 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3601518 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3601519 | 131059 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3601520 | 131059 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3601521 | 131059 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3601522 | 131059 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3601523 | 131059 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3601524 | 131059 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3601525 | 131059 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3601526 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3601527 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3601528 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3601529 | 131059 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3601530 | 131059 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3601531 | 131059 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3601532 | 131059 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3601533 | 131059 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3601534 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3601535 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3601536 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3601537 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3601538 | 131059 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3601539 | 131059 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3601540 | 131059 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3601541 | 131059 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3601542 | 131059 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3601543 | 131059 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3601544 | 131059 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3601545 | 131059 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3601546 | 131059 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3601547 | 131059 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3601548 | 131059 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3601549 | 131059 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3601550 | 131059 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3601551 | 131059 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3601552 | 131059 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3601553 | 131059 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3601554 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3601555 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3601556 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3601557 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3601558 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3601559 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3601560 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3601561 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3601562 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3601563 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3601564 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3601565 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3601566 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3601567 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3601568 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3601569 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3601570 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3601571 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3601572 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3601573 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3601574 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3601575 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3601576 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3601577 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3601578 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3601579 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3601580 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3601581 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3601582 | 131059 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3601583 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3601584 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3601585 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3601586 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3601587 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3601588 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3601589 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3601590 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3601591 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3601592 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3601593 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3601594 | 131059 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3601595 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3601596 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3601597 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3601598 | 131059 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3601599 | 131059 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3601600 | 131059 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3601601 | 131059 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3601602 | 131059 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3601603 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3601604 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3601605 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3601606 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3601607 | 131059 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3601608 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3601609 | 131059 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3601610 | 131059 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3601611 | 131059 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3601612 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3601613 | 131059 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3601614 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3601615 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3601616 | 131059 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3601617 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3601618 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3601619 | 131059 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3601620 | 131059 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3601621 | 131059 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
| 1721810361000 | 0 | None | None | Buildings | Construction of primary health centre at taluvagera, in kushtagi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3601622 | 131060 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3601623 | 131060 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3601624 | 131060 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3601625 | 131060 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3601626 | 131060 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3601627 | 131060 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3601628 | 131060 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3601629 | 131060 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3601630 | 131060 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3601631 | 131060 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3601632 | 131060 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3601633 | 131060 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3601634 | 131060 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3601635 | 131060 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3601636 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3601637 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3601638 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3601639 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3601640 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3601641 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3601642 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3601643 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3601644 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3601645 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3601646 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3601647 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3601648 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3601649 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3601650 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3601651 | 131060 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3601652 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3601653 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3601654 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3601655 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3601656 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3601657 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3601658 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3601659 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3601660 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3601661 | 131060 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3601662 | 131060 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3601663 | 131060 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3601664 | 131060 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3601665 | 131060 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3601666 | 131060 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3601667 | 131060 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3601668 | 131060 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3601669 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3601670 | 131060 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3601671 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3601672 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3601673 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3601674 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3601675 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3601676 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3601677 | 131060 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3601678 | 131060 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3601679 | 131060 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3601680 | 131060 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3601681 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3601682 | 131060 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3601683 | 131060 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3601684 | 131060 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3601685 | 131060 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3601686 | 131060 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3601687 | 131060 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3601688 | 131060 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3601689 | 131060 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3601690 | 131060 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3601691 | 131060 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3601692 | 131060 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3601693 | 131060 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3601694 | 131060 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3601695 | 131060 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3601696 | 131060 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3601697 | 131060 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3601698 | 131060 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3601699 | 131060 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3601700 | 131060 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3601701 | 131060 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3601702 | 131060 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3601703 | 131060 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3601704 | 131060 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3601705 | 131060 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3601706 | 131060 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3601707 | 131060 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3601708 | 131060 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3601709 | 131060 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3601710 | 131060 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3601711 | 131060 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3601712 | 131060 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3601713 | 131060 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3601714 | 131060 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3601715 | 131060 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3601716 | 131060 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3601717 | 131060 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3601718 | 131060 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3601719 | 131060 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3601720 | 131060 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3601721 | 131060 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3601722 | 131060 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3601723 | 131060 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3601724 | 131060 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3601725 | 131060 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3601726 | 131060 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3601727 | 131060 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3601728 | 131060 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3601729 | 131060 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3601730 | 131060 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3601731 | 131060 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3601732 | 131060 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3601733 | 131060 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3601734 | 131060 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3601735 | 131060 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3601736 | 131060 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3601737 | 131060 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3601738 | 131060 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3601739 | 131060 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3601740 | 131060 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3601741 | 131060 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3601742 | 131060 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3601743 | 131060 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3601744 | 131060 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3601745 | 131060 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3601746 | 131060 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3601747 | 131060 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3601748 | 131060 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3601749 | 131060 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3601750 | 131060 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3601751 | 131060 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3601752 | 131060 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3601753 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3601754 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3601755 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3601756 | 131060 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3601757 | 131060 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3601758 | 131060 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3601759 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3601760 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3601761 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3601762 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3601763 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3601764 | 131060 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3601765 | 131060 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3601766 | 131060 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3601767 | 131060 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3601768 | 131060 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3601769 | 131060 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3601770 | 131060 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3601771 | 131060 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3601772 | 131060 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3601773 | 131060 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3601774 | 131060 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3601775 | 131060 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3601776 | 131060 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3601777 | 131060 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3601778 | 131060 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3601779 | 131060 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3601780 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3601781 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3601782 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3601783 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3601784 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3601785 | 131060 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3601786 | 131060 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3601787 | 131060 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3601788 | 131060 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3601789 | 131060 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3601790 | 131060 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3601791 | 131060 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3601792 | 131060 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3601793 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3601794 | 131060 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3601795 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3601796 | 131060 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3601797 | 131060 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3601798 | 131060 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3601799 | 131060 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3601800 | 131060 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3601801 | 131060 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3601802 | 131060 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3601803 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3601804 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3601805 | 131060 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3601806 | 131060 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3601807 | 131060 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3601808 | 131060 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3601809 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3601810 | 131060 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3601811 | 131060 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3601812 | 131060 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3601813 | 131060 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3601814 | 131060 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3601815 | 131060 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3601816 | 131060 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3601817 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3601818 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3601819 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3601820 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3601821 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3601822 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3601823 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3601824 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3601825 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3601826 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3601827 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3601828 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3601829 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3601830 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3601831 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3601832 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3601833 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3601834 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3601835 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3601836 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3601837 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3601838 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3601839 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3601840 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3601841 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3601842 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3601843 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3601844 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3601845 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3601846 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3601847 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3601848 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3601849 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3601850 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3601851 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3601852 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3601853 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3601854 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3601855 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3601856 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3601857 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3601858 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3601859 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3601860 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3601861 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3601862 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3601863 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3601864 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3601865 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3601866 | 131060 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3601867 | 131060 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3601868 | 131060 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3601869 | 131060 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3601870 | 131060 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3601871 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3601872 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3601873 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3601874 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3601875 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3601876 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3601877 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3601878 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3601879 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3601880 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3601881 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3601882 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3601883 | 131060 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3601884 | 131060 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3601885 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3601886 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3601887 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3601888 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3601889 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3601890 | 131060 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3601891 | 131060 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3601892 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3601893 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3601894 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3601895 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3601896 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3601897 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3601898 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3601899 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3601900 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3601901 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3601902 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3601903 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3601904 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3601905 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3601906 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3601907 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3601908 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3601909 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3601910 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3601911 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3601912 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3601913 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3601914 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3601915 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3601916 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3601917 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3601918 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3601919 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3601920 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3601921 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3601922 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3601923 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3601924 | 131060 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3601925 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3601926 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3601927 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3601928 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3601929 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3601930 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3601931 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3601932 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3601933 | 131060 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3601934 | 131060 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3601935 | 131060 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3601936 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3601937 | 131060 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3601938 | 131060 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3601939 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3601940 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3601941 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3601942 | 131060 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3601943 | 131060 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3601944 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3601945 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3601946 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3601947 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3601948 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3601949 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3601950 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3601951 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3601952 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3601953 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3601954 | 131060 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3601955 | 131060 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3601956 | 131060 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3601957 | 131060 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3601958 | 131060 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3601959 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3601960 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3601961 | 131060 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3601962 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3601963 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3601964 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3601965 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3601966 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3601967 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3601968 | 131060 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3601969 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3601970 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3601971 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3601972 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3601973 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3601974 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3601975 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3601976 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3601977 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3601978 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3601979 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3601980 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3601981 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3601982 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3601983 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3601984 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3601985 | 131060 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3601986 | 131060 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3601987 | 131060 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3601988 | 131060 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3601989 | 131060 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3601990 | 131060 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3601991 | 131060 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3601992 | 131060 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3601993 | 131060 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3601994 | 131060 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3601995 | 131060 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3601996 | 131060 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3601997 | 131060 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3601998 | 131060 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3601999 | 131060 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3602000 | 131060 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3602001 | 131060 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3602002 | 131060 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3602003 | 131060 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3602004 | 131060 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3602005 | 131060 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3602006 | 131060 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3602007 | 131060 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3602008 | 131060 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3602009 | 131060 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3602010 | 131060 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3602011 | 131060 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3602012 | 131060 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3602013 | 131060 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3602014 | 131060 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3602015 | 131060 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3602016 | 131060 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3602017 | 131060 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3602018 | 131060 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3602019 | 131060 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3602020 | 131060 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3602021 | 131060 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3602022 | 131060 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3602023 | 131060 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3602024 | 131060 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3602025 | 131060 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3602026 | 131060 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3602027 | 131060 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3602028 | 131060 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3602029 | 131060 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3602030 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3602031 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3602032 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3602033 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3602034 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3602035 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3602036 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3602037 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3602038 | 131060 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3602039 | 131060 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3602040 | 131060 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3602041 | 131060 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3602042 | 131060 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3602043 | 131060 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3602044 | 131060 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3602045 | 131060 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3602046 | 131060 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3602047 | 131060 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3602048 | 131060 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3602049 | 131060 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3602050 | 131060 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3602051 | 131060 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3602052 | 131060 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3602053 | 131060 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3602054 | 131060 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3602055 | 131060 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3602056 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3602057 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3602058 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3602059 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3602060 | 131060 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3602061 | 131060 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3602062 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3602063 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3602064 | 131060 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3602065 | 131060 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3602066 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3602067 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3602068 | 131060 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3602069 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3602070 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3602071 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3602072 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3602073 | 131060 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3602074 | 131060 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3602075 | 131060 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3602076 | 131060 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3602077 | 131060 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3602078 | 131060 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3602079 | 131060 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3602080 | 131060 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3602081 | 131060 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3602082 | 131060 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3602083 | 131060 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3602084 | 131060 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3602085 | 131060 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3602086 | 131060 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3602087 | 131060 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3602088 | 131060 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3602089 | 131060 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3602090 | 131060 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3602091 | 131060 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3602092 | 131060 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3602093 | 131060 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3602094 | 131060 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3602095 | 131060 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3602096 | 131060 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3602097 | 131060 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3602098 | 131060 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3602099 | 131060 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3602100 | 131060 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3602101 | 131060 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3602102 | 131060 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3602103 | 131060 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3602104 | 131060 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3602105 | 131060 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3602106 | 131060 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3602107 | 131060 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3602108 | 131060 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3602109 | 131060 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3602110 | 131060 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3602111 | 131060 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3602112 | 131060 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3602113 | 131060 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3602114 | 131060 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3602115 | 131060 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3602116 | 131060 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3602117 | 131060 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3602118 | 131060 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3602119 | 131060 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3602120 | 131060 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3602121 | 131060 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3602122 | 131060 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3602123 | 131060 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3602124 | 131060 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3602125 | 131060 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3602126 | 131060 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3602127 | 131060 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3602128 | 131060 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3602129 | 131060 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3602130 | 131060 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3602131 | 131060 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3602132 | 131060 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3602133 | 131060 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3602134 | 131060 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3602135 | 131060 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3602136 | 131060 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3602137 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3602138 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3602139 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3602140 | 131060 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3602141 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3602142 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3602143 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3602144 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3602145 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3602146 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3602147 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3602148 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3602149 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3602150 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3602151 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3602152 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3602153 | 131060 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3602154 | 131060 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3602155 | 131060 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3602156 | 131060 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3602157 | 131060 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3602158 | 131060 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3602159 | 131060 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3602160 | 131060 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3602161 | 131060 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3602162 | 131060 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3602163 | 131060 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3602164 | 131060 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3602165 | 131060 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3602166 | 131060 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3602167 | 131060 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3602168 | 131060 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3602169 | 131060 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3602170 | 131060 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3602171 | 131060 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3602172 | 131060 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3602173 | 131060 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3602174 | 131060 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3602175 | 131060 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3602176 | 131060 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3602177 | 131060 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3602178 | 131060 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3602179 | 131060 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3602180 | 131060 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3602181 | 131060 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3602182 | 131060 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3602183 | 131060 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3602184 | 131060 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3602185 | 131060 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3602186 | 131060 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3602187 | 131060 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3602188 | 131060 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3602189 | 131060 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3602190 | 131060 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3602191 | 131060 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3602192 | 131060 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3602193 | 131060 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3602194 | 131060 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3602195 | 131060 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3602196 | 131060 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3602197 | 131060 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3602198 | 131060 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3602199 | 131060 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3602200 | 131060 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3602201 | 131060 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3602202 | 131060 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3602203 | 131060 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3602204 | 131060 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3602205 | 131060 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3602206 | 131060 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3602207 | 131060 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3602208 | 131060 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3602209 | 131060 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3602210 | 131060 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3602211 | 131060 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3602212 | 131060 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3602213 | 131060 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3602214 | 131060 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3602215 | 131060 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3602216 | 131060 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3602217 | 131060 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3602218 | 131060 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3602219 | 131060 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3602220 | 131060 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3602221 | 131060 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3602222 | 131060 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3602223 | 131060 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3602224 | 131060 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3602225 | 131060 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3602226 | 131060 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3602227 | 131060 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3602228 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3602229 | 131060 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3602230 | 131060 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3602231 | 131060 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3602232 | 131060 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3602233 | 131060 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3602234 | 131060 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3602235 | 131060 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3602236 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3602237 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3602238 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3602239 | 131060 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3602240 | 131060 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3602241 | 131060 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3602242 | 131060 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3602243 | 131060 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3602244 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3602245 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3602246 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3602247 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3602248 | 131060 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3602249 | 131060 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3602250 | 131060 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3602251 | 131060 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3602252 | 131060 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3602253 | 131060 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3602254 | 131060 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3602255 | 131060 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3602256 | 131060 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3602257 | 131060 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3602258 | 131060 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3602259 | 131060 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3602260 | 131060 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3602261 | 131060 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3602262 | 131060 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3602263 | 131060 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3602264 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3602265 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3602266 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3602267 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3602268 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3602269 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3602270 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3602271 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3602272 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3602273 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3602274 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3602275 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3602276 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3602277 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3602278 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3602279 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3602280 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3602281 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3602282 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3602283 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3602284 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3602285 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3602286 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3602287 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3602288 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3602289 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3602290 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3602291 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3602292 | 131060 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3602293 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3602294 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3602295 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3602296 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3602297 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3602298 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3602299 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3602300 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3602301 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3602302 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3602303 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3602304 | 131060 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3602305 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3602306 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3602307 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3602308 | 131060 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3602309 | 131060 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3602310 | 131060 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3602311 | 131060 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3602312 | 131060 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3602313 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3602314 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3602315 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3602316 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3602317 | 131060 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3602318 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3602319 | 131060 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3602320 | 131060 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3602321 | 131060 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3602322 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3602323 | 131060 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3602324 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3602325 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3602326 | 131060 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3602327 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3602328 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3602329 | 131060 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3602330 | 131060 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3602331 | 131060 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
| 1721810361000 | 0 | None | None | Buildings | Construction of primary health centre at lingadahalli, in kushtagi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3602332 | 131061 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3602333 | 131061 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3602334 | 131061 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3602335 | 131061 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3602336 | 131061 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3602337 | 131061 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3602338 | 131061 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3602339 | 131061 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3602340 | 131061 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3602341 | 131061 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3602342 | 131061 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3602343 | 131061 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3602344 | 131061 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3602345 | 131061 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3602346 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3602347 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3602348 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3602349 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3602350 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3602351 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3602352 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3602353 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3602354 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3602355 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3602356 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3602357 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3602358 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3602359 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3602360 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3602361 | 131061 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3602362 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3602363 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3602364 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3602365 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3602366 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3602367 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3602368 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3602369 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3602370 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3602371 | 131061 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3602372 | 131061 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3602373 | 131061 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3602374 | 131061 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3602375 | 131061 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3602376 | 131061 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3602377 | 131061 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3602378 | 131061 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3602379 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3602380 | 131061 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3602381 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3602382 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3602383 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3602384 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3602385 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3602386 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3602387 | 131061 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3602388 | 131061 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3602389 | 131061 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3602390 | 131061 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3602391 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3602392 | 131061 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3602393 | 131061 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3602394 | 131061 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3602395 | 131061 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3602396 | 131061 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3602397 | 131061 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3602398 | 131061 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3602399 | 131061 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3602400 | 131061 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3602401 | 131061 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3602402 | 131061 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3602403 | 131061 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3602404 | 131061 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3602405 | 131061 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3602406 | 131061 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3602407 | 131061 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3602408 | 131061 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3602409 | 131061 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3602410 | 131061 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3602411 | 131061 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3602412 | 131061 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3602413 | 131061 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3602414 | 131061 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3602415 | 131061 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3602416 | 131061 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3602417 | 131061 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3602418 | 131061 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3602419 | 131061 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3602420 | 131061 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3602421 | 131061 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3602422 | 131061 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3602423 | 131061 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3602424 | 131061 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3602425 | 131061 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3602426 | 131061 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3602427 | 131061 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3602428 | 131061 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3602429 | 131061 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3602430 | 131061 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3602431 | 131061 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3602432 | 131061 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3602433 | 131061 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3602434 | 131061 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3602435 | 131061 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3602436 | 131061 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3602437 | 131061 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3602438 | 131061 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3602439 | 131061 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3602440 | 131061 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3602441 | 131061 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3602442 | 131061 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3602443 | 131061 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3602444 | 131061 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3602445 | 131061 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3602446 | 131061 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3602447 | 131061 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3602448 | 131061 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3602449 | 131061 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3602450 | 131061 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3602451 | 131061 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3602452 | 131061 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3602453 | 131061 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3602454 | 131061 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3602455 | 131061 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3602456 | 131061 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3602457 | 131061 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3602458 | 131061 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3602459 | 131061 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3602460 | 131061 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3602461 | 131061 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3602462 | 131061 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3602463 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3602464 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3602465 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3602466 | 131061 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3602467 | 131061 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3602468 | 131061 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3602469 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3602470 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3602471 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3602472 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3602473 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3602474 | 131061 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3602475 | 131061 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3602476 | 131061 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3602477 | 131061 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3602478 | 131061 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3602479 | 131061 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3602480 | 131061 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3602481 | 131061 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3602482 | 131061 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3602483 | 131061 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3602484 | 131061 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3602485 | 131061 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3602486 | 131061 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3602487 | 131061 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3602488 | 131061 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3602489 | 131061 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3602490 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3602491 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3602492 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3602493 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3602494 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3602495 | 131061 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3602496 | 131061 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3602497 | 131061 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3602498 | 131061 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3602499 | 131061 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3602500 | 131061 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3602501 | 131061 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3602502 | 131061 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3602503 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3602504 | 131061 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3602505 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3602506 | 131061 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3602507 | 131061 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3602508 | 131061 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3602509 | 131061 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3602510 | 131061 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3602511 | 131061 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3602512 | 131061 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3602513 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3602514 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3602515 | 131061 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3602516 | 131061 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3602517 | 131061 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3602518 | 131061 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3602519 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3602520 | 131061 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3602521 | 131061 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3602522 | 131061 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3602523 | 131061 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3602524 | 131061 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3602525 | 131061 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3602526 | 131061 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3602527 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3602528 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3602529 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3602530 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3602531 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3602532 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3602533 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3602534 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3602535 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3602536 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3602537 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3602538 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3602539 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3602540 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3602541 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3602542 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3602543 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3602544 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3602545 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3602546 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3602547 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3602548 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3602549 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3602550 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3602551 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3602552 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3602553 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3602554 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3602555 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3602556 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3602557 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3602558 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3602559 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3602560 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3602561 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3602562 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3602563 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3602564 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3602565 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3602566 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3602567 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3602568 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3602569 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3602570 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3602571 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3602572 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3602573 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3602574 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3602575 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3602576 | 131061 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3602577 | 131061 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3602578 | 131061 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3602579 | 131061 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3602580 | 131061 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3602581 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3602582 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3602583 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3602584 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3602585 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3602586 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3602587 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3602588 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3602589 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3602590 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3602591 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3602592 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3602593 | 131061 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3602594 | 131061 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3602595 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3602596 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3602597 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3602598 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3602599 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3602600 | 131061 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3602601 | 131061 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3602602 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3602603 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3602604 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3602605 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3602606 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3602607 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3602608 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3602609 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3602610 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3602611 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3602612 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3602613 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3602614 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3602615 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3602616 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3602617 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3602618 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3602619 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3602620 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3602621 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3602622 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3602623 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3602624 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3602625 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3602626 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3602627 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3602628 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3602629 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3602630 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3602631 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3602632 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3602633 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3602634 | 131061 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3602635 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3602636 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3602637 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3602638 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3602639 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3602640 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3602641 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3602642 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3602643 | 131061 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3602644 | 131061 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3602645 | 131061 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3602646 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3602647 | 131061 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3602648 | 131061 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3602649 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3602650 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3602651 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3602652 | 131061 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3602653 | 131061 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3602654 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3602655 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3602656 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3602657 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3602658 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3602659 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3602660 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3602661 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3602662 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3602663 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3602664 | 131061 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3602665 | 131061 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3602666 | 131061 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3602667 | 131061 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3602668 | 131061 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3602669 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3602670 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3602671 | 131061 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3602672 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3602673 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3602674 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3602675 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3602676 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3602677 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3602678 | 131061 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3602679 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3602680 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3602681 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3602682 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3602683 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3602684 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3602685 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3602686 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3602687 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3602688 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3602689 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3602690 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3602691 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3602692 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3602693 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3602694 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3602695 | 131061 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3602696 | 131061 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3602697 | 131061 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3602698 | 131061 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3602699 | 131061 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3602700 | 131061 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3602701 | 131061 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3602702 | 131061 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3602703 | 131061 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3602704 | 131061 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3602705 | 131061 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3602706 | 131061 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3602707 | 131061 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3602708 | 131061 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3602709 | 131061 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3602710 | 131061 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3602711 | 131061 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3602712 | 131061 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3602713 | 131061 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3602714 | 131061 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3602715 | 131061 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3602716 | 131061 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3602717 | 131061 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3602718 | 131061 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3602719 | 131061 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3602720 | 131061 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3602721 | 131061 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3602722 | 131061 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3602723 | 131061 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3602724 | 131061 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3602725 | 131061 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3602726 | 131061 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3602727 | 131061 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3602728 | 131061 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3602729 | 131061 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3602730 | 131061 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3602731 | 131061 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3602732 | 131061 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3602733 | 131061 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3602734 | 131061 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3602735 | 131061 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3602736 | 131061 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3602737 | 131061 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3602738 | 131061 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3602739 | 131061 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3602740 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3602741 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3602742 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3602743 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3602744 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3602745 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3602746 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3602747 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3602748 | 131061 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3602749 | 131061 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3602750 | 131061 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3602751 | 131061 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3602752 | 131061 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3602753 | 131061 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3602754 | 131061 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3602755 | 131061 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3602756 | 131061 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3602757 | 131061 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3602758 | 131061 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3602759 | 131061 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3602760 | 131061 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3602761 | 131061 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3602762 | 131061 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3602763 | 131061 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3602764 | 131061 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3602765 | 131061 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3602766 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3602767 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3602768 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3602769 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3602770 | 131061 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3602771 | 131061 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3602772 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3602773 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3602774 | 131061 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3602775 | 131061 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3602776 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3602777 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3602778 | 131061 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3602779 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3602780 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3602781 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3602782 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3602783 | 131061 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3602784 | 131061 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3602785 | 131061 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3602786 | 131061 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3602787 | 131061 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3602788 | 131061 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3602789 | 131061 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3602790 | 131061 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3602791 | 131061 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3602792 | 131061 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3602793 | 131061 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3602794 | 131061 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3602795 | 131061 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3602796 | 131061 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3602797 | 131061 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3602798 | 131061 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3602799 | 131061 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3602800 | 131061 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3602801 | 131061 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3602802 | 131061 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3602803 | 131061 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3602804 | 131061 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3602805 | 131061 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3602806 | 131061 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3602807 | 131061 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3602808 | 131061 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3602809 | 131061 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3602810 | 131061 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3602811 | 131061 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3602812 | 131061 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3602813 | 131061 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3602814 | 131061 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3602815 | 131061 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3602816 | 131061 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3602817 | 131061 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3602818 | 131061 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3602819 | 131061 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3602820 | 131061 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3602821 | 131061 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3602822 | 131061 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3602823 | 131061 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3602824 | 131061 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3602825 | 131061 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3602826 | 131061 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3602827 | 131061 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3602828 | 131061 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3602829 | 131061 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3602830 | 131061 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3602831 | 131061 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3602832 | 131061 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3602833 | 131061 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3602834 | 131061 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3602835 | 131061 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3602836 | 131061 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3602837 | 131061 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3602838 | 131061 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3602839 | 131061 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3602840 | 131061 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3602841 | 131061 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3602842 | 131061 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3602843 | 131061 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3602844 | 131061 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3602845 | 131061 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3602846 | 131061 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3602847 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3602848 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3602849 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3602850 | 131061 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3602851 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3602852 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3602853 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3602854 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3602855 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3602856 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3602857 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3602858 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3602859 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3602860 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3602861 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3602862 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3602863 | 131061 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3602864 | 131061 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3602865 | 131061 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3602866 | 131061 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3602867 | 131061 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3602868 | 131061 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3602869 | 131061 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3602870 | 131061 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3602871 | 131061 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3602872 | 131061 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3602873 | 131061 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3602874 | 131061 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3602875 | 131061 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3602876 | 131061 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3602877 | 131061 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3602878 | 131061 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3602879 | 131061 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3602880 | 131061 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3602881 | 131061 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3602882 | 131061 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3602883 | 131061 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3602884 | 131061 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3602885 | 131061 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3602886 | 131061 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3602887 | 131061 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3602888 | 131061 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3602889 | 131061 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3602890 | 131061 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3602891 | 131061 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3602892 | 131061 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3602893 | 131061 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3602894 | 131061 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3602895 | 131061 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3602896 | 131061 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3602897 | 131061 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3602898 | 131061 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3602899 | 131061 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3602900 | 131061 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3602901 | 131061 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3602902 | 131061 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3602903 | 131061 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3602904 | 131061 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3602905 | 131061 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3602906 | 131061 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3602907 | 131061 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3602908 | 131061 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3602909 | 131061 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3602910 | 131061 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3602911 | 131061 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3602912 | 131061 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3602913 | 131061 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3602914 | 131061 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3602915 | 131061 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3602916 | 131061 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3602917 | 131061 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3602918 | 131061 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3602919 | 131061 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3602920 | 131061 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3602921 | 131061 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3602922 | 131061 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3602923 | 131061 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3602924 | 131061 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3602925 | 131061 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3602926 | 131061 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3602927 | 131061 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3602928 | 131061 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3602929 | 131061 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3602930 | 131061 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3602931 | 131061 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3602932 | 131061 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3602933 | 131061 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3602934 | 131061 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3602935 | 131061 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3602936 | 131061 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3602937 | 131061 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3602938 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3602939 | 131061 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3602940 | 131061 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3602941 | 131061 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3602942 | 131061 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3602943 | 131061 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3602944 | 131061 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3602945 | 131061 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3602946 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3602947 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3602948 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3602949 | 131061 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3602950 | 131061 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3602951 | 131061 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3602952 | 131061 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3602953 | 131061 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3602954 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3602955 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3602956 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3602957 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3602958 | 131061 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3602959 | 131061 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3602960 | 131061 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3602961 | 131061 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3602962 | 131061 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3602963 | 131061 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3602964 | 131061 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3602965 | 131061 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3602966 | 131061 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3602967 | 131061 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3602968 | 131061 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3602969 | 131061 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3602970 | 131061 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3602971 | 131061 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3602972 | 131061 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3602973 | 131061 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3602974 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3602975 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3602976 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3602977 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3602978 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3602979 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3602980 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3602981 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3602982 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3602983 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3602984 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3602985 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3602986 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3602987 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3602988 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3602989 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3602990 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3602991 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3602992 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3602993 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3602994 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3602995 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3602996 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3602997 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3602998 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3602999 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3603000 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3603001 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3603002 | 131061 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3603003 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3603004 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3603005 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3603006 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3603007 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3603008 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3603009 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3603010 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3603011 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3603012 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3603013 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3603014 | 131061 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3603015 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3603016 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3603017 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3603018 | 131061 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3603019 | 131061 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3603020 | 131061 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3603021 | 131061 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3603022 | 131061 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3603023 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3603024 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3603025 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3603026 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3603027 | 131061 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3603028 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3603029 | 131061 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3603030 | 131061 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3603031 | 131061 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3603032 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3603033 | 131061 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3603034 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3603035 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3603036 | 131061 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3603037 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3603038 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3603039 | 131061 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3603040 | 131061 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3603041 | 131061 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
| 1721810361000 | 0 | None | None | Buildings | Construction of primary health centre at hirebannigol, in kushtagi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3603042 | 131062 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3603043 | 131062 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3603044 | 131062 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3603045 | 131062 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3603046 | 131062 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3603047 | 131062 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3603048 | 131062 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3603049 | 131062 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3603050 | 131062 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3603051 | 131062 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3603052 | 131062 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3603053 | 131062 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3603054 | 131062 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3603055 | 131062 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3603056 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3603057 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3603058 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3603059 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3603060 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3603061 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3603062 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3603063 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3603064 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3603065 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3603066 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3603067 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3603068 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3603069 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3603070 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3603071 | 131062 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3603072 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3603073 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3603074 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3603075 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3603076 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3603077 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3603078 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3603079 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3603080 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3603081 | 131062 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3603082 | 131062 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3603083 | 131062 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3603084 | 131062 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3603085 | 131062 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3603086 | 131062 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3603087 | 131062 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3603088 | 131062 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3603089 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3603090 | 131062 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3603091 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3603092 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3603093 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3603094 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3603095 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3603096 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3603097 | 131062 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3603098 | 131062 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3603099 | 131062 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3603100 | 131062 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3603101 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3603102 | 131062 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3603103 | 131062 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3603104 | 131062 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3603105 | 131062 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3603106 | 131062 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3603107 | 131062 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3603108 | 131062 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3603109 | 131062 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3603110 | 131062 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3603111 | 131062 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3603112 | 131062 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3603113 | 131062 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3603114 | 131062 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3603115 | 131062 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3603116 | 131062 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3603117 | 131062 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3603118 | 131062 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3603119 | 131062 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3603120 | 131062 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3603121 | 131062 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3603122 | 131062 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3603123 | 131062 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3603124 | 131062 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3603125 | 131062 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3603126 | 131062 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3603127 | 131062 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3603128 | 131062 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3603129 | 131062 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3603130 | 131062 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3603131 | 131062 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3603132 | 131062 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3603133 | 131062 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3603134 | 131062 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3603135 | 131062 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3603136 | 131062 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3603137 | 131062 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3603138 | 131062 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3603139 | 131062 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3603140 | 131062 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3603141 | 131062 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3603142 | 131062 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3603143 | 131062 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3603144 | 131062 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3603145 | 131062 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3603146 | 131062 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3603147 | 131062 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3603148 | 131062 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3603149 | 131062 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3603150 | 131062 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3603151 | 131062 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3603152 | 131062 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3603153 | 131062 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3603154 | 131062 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3603155 | 131062 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3603156 | 131062 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3603157 | 131062 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3603158 | 131062 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3603159 | 131062 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3603160 | 131062 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3603161 | 131062 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3603162 | 131062 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3603163 | 131062 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3603164 | 131062 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3603165 | 131062 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3603166 | 131062 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3603167 | 131062 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3603168 | 131062 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3603169 | 131062 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3603170 | 131062 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3603171 | 131062 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3603172 | 131062 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3603173 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3603174 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3603175 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3603176 | 131062 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3603177 | 131062 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3603178 | 131062 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3603179 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3603180 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3603181 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3603182 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3603183 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3603184 | 131062 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3603185 | 131062 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3603186 | 131062 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3603187 | 131062 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3603188 | 131062 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3603189 | 131062 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3603190 | 131062 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3603191 | 131062 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3603192 | 131062 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3603193 | 131062 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3603194 | 131062 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3603195 | 131062 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3603196 | 131062 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3603197 | 131062 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3603198 | 131062 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3603199 | 131062 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3603200 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3603201 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3603202 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3603203 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3603204 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3603205 | 131062 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3603206 | 131062 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3603207 | 131062 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3603208 | 131062 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3603209 | 131062 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3603210 | 131062 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3603211 | 131062 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3603212 | 131062 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3603213 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3603214 | 131062 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3603215 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3603216 | 131062 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3603217 | 131062 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3603218 | 131062 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3603219 | 131062 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3603220 | 131062 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3603221 | 131062 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3603222 | 131062 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3603223 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3603224 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3603225 | 131062 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3603226 | 131062 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3603227 | 131062 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3603228 | 131062 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3603229 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3603230 | 131062 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3603231 | 131062 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3603232 | 131062 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3603233 | 131062 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3603234 | 131062 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3603235 | 131062 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3603236 | 131062 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3603237 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3603238 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3603239 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3603240 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3603241 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3603242 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3603243 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3603244 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3603245 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3603246 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3603247 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3603248 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3603249 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3603250 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3603251 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3603252 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3603253 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3603254 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3603255 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3603256 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3603257 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3603258 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3603259 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3603260 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3603261 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3603262 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3603263 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3603264 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3603265 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3603266 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3603267 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3603268 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3603269 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3603270 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3603271 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3603272 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3603273 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3603274 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3603275 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3603276 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3603277 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3603278 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3603279 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3603280 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3603281 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3603282 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3603283 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3603284 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3603285 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3603286 | 131062 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3603287 | 131062 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3603288 | 131062 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3603289 | 131062 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3603290 | 131062 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3603291 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3603292 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3603293 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3603294 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3603295 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3603296 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3603297 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3603298 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3603299 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3603300 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3603301 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3603302 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3603303 | 131062 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3603304 | 131062 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3603305 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3603306 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3603307 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3603308 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3603309 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3603310 | 131062 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3603311 | 131062 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3603312 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3603313 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3603314 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3603315 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3603316 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3603317 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3603318 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3603319 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3603320 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3603321 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3603322 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3603323 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3603324 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3603325 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3603326 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3603327 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3603328 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3603329 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3603330 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3603331 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3603332 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3603333 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3603334 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3603335 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3603336 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3603337 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3603338 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3603339 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3603340 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3603341 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3603342 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3603343 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3603344 | 131062 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3603345 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3603346 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3603347 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3603348 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3603349 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3603350 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3603351 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3603352 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3603353 | 131062 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3603354 | 131062 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3603355 | 131062 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3603356 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3603357 | 131062 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3603358 | 131062 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3603359 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3603360 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3603361 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3603362 | 131062 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3603363 | 131062 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3603364 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3603365 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3603366 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3603367 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3603368 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3603369 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3603370 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3603371 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3603372 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3603373 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3603374 | 131062 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3603375 | 131062 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3603376 | 131062 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3603377 | 131062 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3603378 | 131062 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3603379 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3603380 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3603381 | 131062 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3603382 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3603383 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3603384 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3603385 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3603386 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3603387 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3603388 | 131062 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3603389 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3603390 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3603391 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3603392 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3603393 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3603394 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3603395 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3603396 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3603397 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3603398 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3603399 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3603400 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3603401 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3603402 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3603403 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3603404 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3603405 | 131062 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3603406 | 131062 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3603407 | 131062 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3603408 | 131062 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3603409 | 131062 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3603410 | 131062 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3603411 | 131062 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3603412 | 131062 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3603413 | 131062 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3603414 | 131062 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3603415 | 131062 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3603416 | 131062 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3603417 | 131062 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3603418 | 131062 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3603419 | 131062 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3603420 | 131062 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3603421 | 131062 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3603422 | 131062 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3603423 | 131062 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3603424 | 131062 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3603425 | 131062 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3603426 | 131062 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3603427 | 131062 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3603428 | 131062 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3603429 | 131062 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3603430 | 131062 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3603431 | 131062 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3603432 | 131062 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3603433 | 131062 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3603434 | 131062 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3603435 | 131062 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3603436 | 131062 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3603437 | 131062 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3603438 | 131062 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3603439 | 131062 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3603440 | 131062 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3603441 | 131062 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3603442 | 131062 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3603443 | 131062 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3603444 | 131062 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3603445 | 131062 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3603446 | 131062 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3603447 | 131062 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3603448 | 131062 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3603449 | 131062 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3603450 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3603451 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3603452 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3603453 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3603454 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3603455 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3603456 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3603457 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3603458 | 131062 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3603459 | 131062 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3603460 | 131062 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3603461 | 131062 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3603462 | 131062 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3603463 | 131062 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3603464 | 131062 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3603465 | 131062 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3603466 | 131062 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3603467 | 131062 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3603468 | 131062 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3603469 | 131062 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3603470 | 131062 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3603471 | 131062 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3603472 | 131062 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3603473 | 131062 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3603474 | 131062 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3603475 | 131062 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3603476 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3603477 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3603478 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3603479 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3603480 | 131062 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3603481 | 131062 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3603482 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3603483 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3603484 | 131062 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3603485 | 131062 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3603486 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3603487 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3603488 | 131062 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3603489 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3603490 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3603491 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3603492 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3603493 | 131062 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3603494 | 131062 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3603495 | 131062 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3603496 | 131062 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3603497 | 131062 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3603498 | 131062 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3603499 | 131062 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3603500 | 131062 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3603501 | 131062 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3603502 | 131062 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3603503 | 131062 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3603504 | 131062 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3603505 | 131062 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3603506 | 131062 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3603507 | 131062 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3603508 | 131062 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3603509 | 131062 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3603510 | 131062 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3603511 | 131062 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3603512 | 131062 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3603513 | 131062 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3603514 | 131062 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3603515 | 131062 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3603516 | 131062 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3603517 | 131062 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3603518 | 131062 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3603519 | 131062 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3603520 | 131062 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3603521 | 131062 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3603522 | 131062 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3603523 | 131062 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3603524 | 131062 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3603525 | 131062 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3603526 | 131062 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3603527 | 131062 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3603528 | 131062 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3603529 | 131062 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3603530 | 131062 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3603531 | 131062 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3603532 | 131062 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3603533 | 131062 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3603534 | 131062 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3603535 | 131062 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3603536 | 131062 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3603537 | 131062 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3603538 | 131062 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3603539 | 131062 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3603540 | 131062 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3603541 | 131062 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3603542 | 131062 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3603543 | 131062 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3603544 | 131062 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3603545 | 131062 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3603546 | 131062 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3603547 | 131062 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3603548 | 131062 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3603549 | 131062 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3603550 | 131062 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3603551 | 131062 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3603552 | 131062 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3603553 | 131062 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3603554 | 131062 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3603555 | 131062 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3603556 | 131062 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3603557 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3603558 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3603559 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3603560 | 131062 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3603561 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3603562 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3603563 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3603564 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3603565 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3603566 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3603567 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3603568 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3603569 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3603570 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3603571 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3603572 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3603573 | 131062 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3603574 | 131062 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3603575 | 131062 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3603576 | 131062 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3603577 | 131062 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3603578 | 131062 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3603579 | 131062 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3603580 | 131062 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3603581 | 131062 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3603582 | 131062 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3603583 | 131062 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3603584 | 131062 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3603585 | 131062 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3603586 | 131062 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3603587 | 131062 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3603588 | 131062 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3603589 | 131062 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3603590 | 131062 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3603591 | 131062 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3603592 | 131062 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3603593 | 131062 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3603594 | 131062 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3603595 | 131062 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3603596 | 131062 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3603597 | 131062 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3603598 | 131062 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3603599 | 131062 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3603600 | 131062 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3603601 | 131062 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3603602 | 131062 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3603603 | 131062 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3603604 | 131062 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3603605 | 131062 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3603606 | 131062 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3603607 | 131062 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3603608 | 131062 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3603609 | 131062 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3603610 | 131062 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3603611 | 131062 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3603612 | 131062 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3603613 | 131062 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3603614 | 131062 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3603615 | 131062 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3603616 | 131062 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3603617 | 131062 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3603618 | 131062 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3603619 | 131062 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3603620 | 131062 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3603621 | 131062 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3603622 | 131062 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3603623 | 131062 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3603624 | 131062 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3603625 | 131062 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3603626 | 131062 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3603627 | 131062 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3603628 | 131062 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3603629 | 131062 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3603630 | 131062 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3603631 | 131062 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3603632 | 131062 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3603633 | 131062 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3603634 | 131062 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3603635 | 131062 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3603636 | 131062 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3603637 | 131062 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3603638 | 131062 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3603639 | 131062 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3603640 | 131062 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3603641 | 131062 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3603642 | 131062 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3603643 | 131062 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3603644 | 131062 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3603645 | 131062 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3603646 | 131062 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3603647 | 131062 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3603648 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3603649 | 131062 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3603650 | 131062 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3603651 | 131062 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3603652 | 131062 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3603653 | 131062 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3603654 | 131062 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3603655 | 131062 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3603656 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3603657 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3603658 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3603659 | 131062 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3603660 | 131062 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3603661 | 131062 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3603662 | 131062 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3603663 | 131062 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3603664 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3603665 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3603666 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3603667 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3603668 | 131062 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3603669 | 131062 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3603670 | 131062 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3603671 | 131062 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3603672 | 131062 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3603673 | 131062 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3603674 | 131062 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3603675 | 131062 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3603676 | 131062 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3603677 | 131062 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3603678 | 131062 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3603679 | 131062 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3603680 | 131062 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3603681 | 131062 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3603682 | 131062 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3603683 | 131062 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3603684 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3603685 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3603686 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3603687 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3603688 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3603689 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3603690 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3603691 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3603692 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3603693 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3603694 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3603695 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3603696 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3603697 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3603698 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3603699 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3603700 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3603701 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3603702 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3603703 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3603704 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3603705 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3603706 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3603707 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3603708 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3603709 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3603710 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3603711 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3603712 | 131062 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3603713 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3603714 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3603715 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3603716 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3603717 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3603718 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3603719 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3603720 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3603721 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3603722 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3603723 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3603724 | 131062 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3603725 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3603726 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3603727 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3603728 | 131062 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3603729 | 131062 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3603730 | 131062 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3603731 | 131062 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3603732 | 131062 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3603733 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3603734 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3603735 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3603736 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3603737 | 131062 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3603738 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3603739 | 131062 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3603740 | 131062 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3603741 | 131062 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3603742 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3603743 | 131062 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3603744 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3603745 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3603746 | 131062 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3603747 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3603748 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3603749 | 131062 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3603750 | 131062 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3603751 | 131062 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
| 1721810362000 | 0 | None | None | Buildings | Construction of primary health centre at singanala, in gangavathi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3603752 | 131063 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3603753 | 131063 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3603754 | 131063 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3603755 | 131063 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3603756 | 131063 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3603757 | 131063 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3603758 | 131063 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3603759 | 131063 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3603760 | 131063 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3603761 | 131063 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3603762 | 131063 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3603763 | 131063 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3603764 | 131063 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3603765 | 131063 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3603766 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3603767 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3603768 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3603769 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3603770 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3603771 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3603772 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3603773 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3603774 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3603775 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3603776 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3603777 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3603778 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3603779 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3603780 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3603781 | 131063 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3603782 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3603783 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3603784 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3603785 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3603786 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3603787 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3603788 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3603789 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3603790 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3603791 | 131063 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3603792 | 131063 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3603793 | 131063 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3603794 | 131063 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3603795 | 131063 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3603796 | 131063 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3603797 | 131063 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3603798 | 131063 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3603799 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3603800 | 131063 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3603801 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3603802 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3603803 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3603804 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3603805 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3603806 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3603807 | 131063 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3603808 | 131063 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3603809 | 131063 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3603810 | 131063 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3603811 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3603812 | 131063 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3603813 | 131063 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3603814 | 131063 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3603815 | 131063 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3603816 | 131063 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3603817 | 131063 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3603818 | 131063 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3603819 | 131063 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3603820 | 131063 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3603821 | 131063 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3603822 | 131063 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3603823 | 131063 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3603824 | 131063 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3603825 | 131063 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3603826 | 131063 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3603827 | 131063 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3603828 | 131063 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3603829 | 131063 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3603830 | 131063 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3603831 | 131063 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3603832 | 131063 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3603833 | 131063 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3603834 | 131063 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3603835 | 131063 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3603836 | 131063 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3603837 | 131063 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3603838 | 131063 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3603839 | 131063 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3603840 | 131063 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3603841 | 131063 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3603842 | 131063 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3603843 | 131063 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3603844 | 131063 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3603845 | 131063 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3603846 | 131063 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3603847 | 131063 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3603848 | 131063 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3603849 | 131063 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3603850 | 131063 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3603851 | 131063 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3603852 | 131063 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3603853 | 131063 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3603854 | 131063 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3603855 | 131063 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3603856 | 131063 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3603857 | 131063 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3603858 | 131063 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3603859 | 131063 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3603860 | 131063 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3603861 | 131063 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3603862 | 131063 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3603863 | 131063 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3603864 | 131063 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3603865 | 131063 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3603866 | 131063 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3603867 | 131063 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3603868 | 131063 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3603869 | 131063 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3603870 | 131063 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3603871 | 131063 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3603872 | 131063 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3603873 | 131063 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3603874 | 131063 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3603875 | 131063 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3603876 | 131063 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3603877 | 131063 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3603878 | 131063 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3603879 | 131063 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3603880 | 131063 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3603881 | 131063 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3603882 | 131063 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3603883 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3603884 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3603885 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3603886 | 131063 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3603887 | 131063 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3603888 | 131063 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3603889 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3603890 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3603891 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3603892 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3603893 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3603894 | 131063 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3603895 | 131063 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3603896 | 131063 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3603897 | 131063 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3603898 | 131063 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3603899 | 131063 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3603900 | 131063 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3603901 | 131063 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3603902 | 131063 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3603903 | 131063 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3603904 | 131063 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3603905 | 131063 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3603906 | 131063 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3603907 | 131063 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3603908 | 131063 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3603909 | 131063 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3603910 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3603911 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3603912 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3603913 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3603914 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3603915 | 131063 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3603916 | 131063 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3603917 | 131063 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3603918 | 131063 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3603919 | 131063 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3603920 | 131063 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3603921 | 131063 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3603922 | 131063 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3603923 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3603924 | 131063 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3603925 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3603926 | 131063 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3603927 | 131063 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3603928 | 131063 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3603929 | 131063 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3603930 | 131063 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3603931 | 131063 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3603932 | 131063 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3603933 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3603934 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3603935 | 131063 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3603936 | 131063 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3603937 | 131063 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3603938 | 131063 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3603939 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3603940 | 131063 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3603941 | 131063 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3603942 | 131063 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3603943 | 131063 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3603944 | 131063 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3603945 | 131063 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3603946 | 131063 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3603947 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3603948 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3603949 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3603950 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3603951 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3603952 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3603953 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3603954 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3603955 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3603956 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3603957 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3603958 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3603959 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3603960 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3603961 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3603962 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3603963 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3603964 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3603965 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3603966 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3603967 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3603968 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3603969 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3603970 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3603971 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3603972 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3603973 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3603974 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3603975 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3603976 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3603977 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3603978 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3603979 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3603980 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3603981 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3603982 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3603983 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3603984 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3603985 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3603986 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3603987 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3603988 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3603989 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3603990 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3603991 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3603992 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3603993 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3603994 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3603995 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3603996 | 131063 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3603997 | 131063 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3603998 | 131063 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3603999 | 131063 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3604000 | 131063 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3604001 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3604002 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3604003 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3604004 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3604005 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3604006 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3604007 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3604008 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3604009 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3604010 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3604011 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3604012 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3604013 | 131063 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3604014 | 131063 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3604015 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3604016 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3604017 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3604018 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3604019 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3604020 | 131063 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3604021 | 131063 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3604022 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3604023 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3604024 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3604025 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3604026 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3604027 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3604028 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3604029 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3604030 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3604031 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3604032 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3604033 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3604034 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3604035 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3604036 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3604037 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3604038 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3604039 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3604040 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3604041 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3604042 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3604043 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3604044 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3604045 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3604046 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3604047 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3604048 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3604049 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3604050 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3604051 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3604052 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3604053 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3604054 | 131063 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3604055 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3604056 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3604057 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3604058 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3604059 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3604060 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3604061 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3604062 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3604063 | 131063 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3604064 | 131063 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3604065 | 131063 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3604066 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3604067 | 131063 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3604068 | 131063 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3604069 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3604070 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3604071 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3604072 | 131063 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3604073 | 131063 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3604074 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3604075 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3604076 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3604077 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3604078 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3604079 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3604080 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3604081 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3604082 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3604083 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3604084 | 131063 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3604085 | 131063 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3604086 | 131063 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3604087 | 131063 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3604088 | 131063 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3604089 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3604090 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3604091 | 131063 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3604092 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3604093 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3604094 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3604095 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3604096 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3604097 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3604098 | 131063 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3604099 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3604100 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3604101 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3604102 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3604103 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3604104 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3604105 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3604106 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3604107 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3604108 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3604109 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3604110 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3604111 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3604112 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3604113 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3604114 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3604115 | 131063 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3604116 | 131063 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3604117 | 131063 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3604118 | 131063 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3604119 | 131063 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3604120 | 131063 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3604121 | 131063 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3604122 | 131063 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3604123 | 131063 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3604124 | 131063 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3604125 | 131063 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3604126 | 131063 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3604127 | 131063 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3604128 | 131063 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3604129 | 131063 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3604130 | 131063 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3604131 | 131063 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3604132 | 131063 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3604133 | 131063 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3604134 | 131063 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3604135 | 131063 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3604136 | 131063 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3604137 | 131063 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3604138 | 131063 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3604139 | 131063 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3604140 | 131063 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3604141 | 131063 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3604142 | 131063 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3604143 | 131063 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3604144 | 131063 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3604145 | 131063 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3604146 | 131063 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3604147 | 131063 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3604148 | 131063 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3604149 | 131063 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3604150 | 131063 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3604151 | 131063 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3604152 | 131063 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3604153 | 131063 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3604154 | 131063 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3604155 | 131063 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3604156 | 131063 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3604157 | 131063 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3604158 | 131063 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3604159 | 131063 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3604160 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3604161 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3604162 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3604163 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3604164 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3604165 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3604166 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3604167 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3604168 | 131063 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3604169 | 131063 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3604170 | 131063 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3604171 | 131063 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3604172 | 131063 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3604173 | 131063 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3604174 | 131063 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3604175 | 131063 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3604176 | 131063 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3604177 | 131063 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3604178 | 131063 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3604179 | 131063 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3604180 | 131063 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3604181 | 131063 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3604182 | 131063 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3604183 | 131063 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3604184 | 131063 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3604185 | 131063 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3604186 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3604187 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3604188 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3604189 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3604190 | 131063 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3604191 | 131063 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3604192 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3604193 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3604194 | 131063 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3604195 | 131063 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3604196 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3604197 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3604198 | 131063 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3604199 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3604200 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3604201 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3604202 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3604203 | 131063 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3604204 | 131063 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3604205 | 131063 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3604206 | 131063 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3604207 | 131063 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3604208 | 131063 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3604209 | 131063 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3604210 | 131063 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3604211 | 131063 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3604212 | 131063 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3604213 | 131063 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3604214 | 131063 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3604215 | 131063 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3604216 | 131063 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3604217 | 131063 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3604218 | 131063 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3604219 | 131063 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3604220 | 131063 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3604221 | 131063 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3604222 | 131063 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3604223 | 131063 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3604224 | 131063 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3604225 | 131063 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3604226 | 131063 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3604227 | 131063 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3604228 | 131063 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3604229 | 131063 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3604230 | 131063 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3604231 | 131063 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3604232 | 131063 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3604233 | 131063 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3604234 | 131063 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3604235 | 131063 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3604236 | 131063 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3604237 | 131063 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3604238 | 131063 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3604239 | 131063 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3604240 | 131063 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3604241 | 131063 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3604242 | 131063 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3604243 | 131063 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3604244 | 131063 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3604245 | 131063 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3604246 | 131063 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3604247 | 131063 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3604248 | 131063 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3604249 | 131063 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3604250 | 131063 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3604251 | 131063 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3604252 | 131063 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3604253 | 131063 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3604254 | 131063 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3604255 | 131063 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3604256 | 131063 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3604257 | 131063 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3604258 | 131063 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3604259 | 131063 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3604260 | 131063 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3604261 | 131063 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3604262 | 131063 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3604263 | 131063 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3604264 | 131063 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3604265 | 131063 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3604266 | 131063 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3604267 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3604268 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3604269 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3604270 | 131063 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3604271 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3604272 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3604273 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3604274 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3604275 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3604276 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3604277 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3604278 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3604279 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3604280 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3604281 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3604282 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3604283 | 131063 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3604284 | 131063 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3604285 | 131063 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3604286 | 131063 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3604287 | 131063 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3604288 | 131063 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3604289 | 131063 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3604290 | 131063 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3604291 | 131063 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3604292 | 131063 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3604293 | 131063 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3604294 | 131063 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3604295 | 131063 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3604296 | 131063 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3604297 | 131063 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3604298 | 131063 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3604299 | 131063 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3604300 | 131063 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3604301 | 131063 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3604302 | 131063 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3604303 | 131063 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3604304 | 131063 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3604305 | 131063 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3604306 | 131063 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3604307 | 131063 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3604308 | 131063 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3604309 | 131063 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3604310 | 131063 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3604311 | 131063 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3604312 | 131063 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3604313 | 131063 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3604314 | 131063 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3604315 | 131063 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3604316 | 131063 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3604317 | 131063 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3604318 | 131063 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3604319 | 131063 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3604320 | 131063 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3604321 | 131063 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3604322 | 131063 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3604323 | 131063 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3604324 | 131063 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3604325 | 131063 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3604326 | 131063 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3604327 | 131063 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3604328 | 131063 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3604329 | 131063 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3604330 | 131063 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3604331 | 131063 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3604332 | 131063 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3604333 | 131063 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3604334 | 131063 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3604335 | 131063 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3604336 | 131063 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3604337 | 131063 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3604338 | 131063 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3604339 | 131063 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3604340 | 131063 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3604341 | 131063 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3604342 | 131063 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3604343 | 131063 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3604344 | 131063 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3604345 | 131063 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3604346 | 131063 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3604347 | 131063 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3604348 | 131063 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3604349 | 131063 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3604350 | 131063 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3604351 | 131063 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3604352 | 131063 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3604353 | 131063 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3604354 | 131063 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3604355 | 131063 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3604356 | 131063 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3604357 | 131063 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3604358 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3604359 | 131063 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3604360 | 131063 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3604361 | 131063 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3604362 | 131063 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3604363 | 131063 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3604364 | 131063 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3604365 | 131063 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3604366 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3604367 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3604368 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3604369 | 131063 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3604370 | 131063 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3604371 | 131063 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3604372 | 131063 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3604373 | 131063 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3604374 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3604375 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3604376 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3604377 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3604378 | 131063 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3604379 | 131063 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3604380 | 131063 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3604381 | 131063 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3604382 | 131063 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3604383 | 131063 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3604384 | 131063 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3604385 | 131063 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3604386 | 131063 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3604387 | 131063 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3604388 | 131063 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3604389 | 131063 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3604390 | 131063 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3604391 | 131063 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3604392 | 131063 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3604393 | 131063 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3604394 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3604395 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3604396 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3604397 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3604398 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3604399 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3604400 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3604401 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3604402 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3604403 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3604404 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3604405 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3604406 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3604407 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3604408 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3604409 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3604410 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3604411 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3604412 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3604413 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3604414 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3604415 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3604416 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3604417 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3604418 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3604419 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3604420 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3604421 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3604422 | 131063 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3604423 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3604424 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3604425 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3604426 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3604427 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3604428 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3604429 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3604430 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3604431 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3604432 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3604433 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3604434 | 131063 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3604435 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3604436 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3604437 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3604438 | 131063 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3604439 | 131063 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3604440 | 131063 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3604441 | 131063 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3604442 | 131063 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3604443 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3604444 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3604445 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3604446 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3604447 | 131063 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3604448 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3604449 | 131063 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3604450 | 131063 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3604451 | 131063 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3604452 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3604453 | 131063 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3604454 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3604455 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3604456 | 131063 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3604457 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3604458 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3604459 | 131063 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3604460 | 131063 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3604461 | 131063 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
| 1721810362000 | 0 | None | None | Buildings | Construction of primary health centre at jeeral, in gangavathi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3604462 | 131064 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3604463 | 131064 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3604464 | 131064 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3604465 | 131064 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3604466 | 131064 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3604467 | 131064 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3604468 | 131064 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3604469 | 131064 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3604470 | 131064 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3604471 | 131064 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3604472 | 131064 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3604473 | 131064 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3604474 | 131064 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3604475 | 131064 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3604476 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3604477 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3604478 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3604479 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3604480 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3604481 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3604482 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3604483 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3604484 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3604485 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3604486 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3604487 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3604488 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3604489 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3604490 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3604491 | 131064 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3604492 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3604493 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3604494 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3604495 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3604496 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3604497 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3604498 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3604499 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3604500 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3604501 | 131064 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3604502 | 131064 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3604503 | 131064 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3604504 | 131064 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3604505 | 131064 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3604506 | 131064 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3604507 | 131064 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3604508 | 131064 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3604509 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3604510 | 131064 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3604511 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3604512 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3604513 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3604514 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3604515 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3604516 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3604517 | 131064 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3604518 | 131064 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3604519 | 131064 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3604520 | 131064 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3604521 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3604522 | 131064 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3604523 | 131064 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3604524 | 131064 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3604525 | 131064 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3604526 | 131064 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3604527 | 131064 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3604528 | 131064 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3604529 | 131064 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3604530 | 131064 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3604531 | 131064 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3604532 | 131064 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3604533 | 131064 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3604534 | 131064 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3604535 | 131064 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3604536 | 131064 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3604537 | 131064 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3604538 | 131064 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3604539 | 131064 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3604540 | 131064 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3604541 | 131064 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3604542 | 131064 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3604543 | 131064 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3604544 | 131064 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3604545 | 131064 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3604546 | 131064 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3604547 | 131064 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3604548 | 131064 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3604549 | 131064 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3604550 | 131064 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3604551 | 131064 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3604552 | 131064 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3604553 | 131064 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3604554 | 131064 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3604555 | 131064 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3604556 | 131064 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3604557 | 131064 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3604558 | 131064 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3604559 | 131064 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3604560 | 131064 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3604561 | 131064 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3604562 | 131064 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3604563 | 131064 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3604564 | 131064 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3604565 | 131064 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3604566 | 131064 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3604567 | 131064 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3604568 | 131064 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3604569 | 131064 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3604570 | 131064 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3604571 | 131064 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3604572 | 131064 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3604573 | 131064 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3604574 | 131064 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3604575 | 131064 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3604576 | 131064 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3604577 | 131064 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3604578 | 131064 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3604579 | 131064 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3604580 | 131064 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3604581 | 131064 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3604582 | 131064 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3604583 | 131064 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3604584 | 131064 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3604585 | 131064 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3604586 | 131064 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3604587 | 131064 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3604588 | 131064 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3604589 | 131064 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3604590 | 131064 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3604591 | 131064 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3604592 | 131064 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3604593 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3604594 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3604595 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3604596 | 131064 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3604597 | 131064 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3604598 | 131064 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3604599 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3604600 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3604601 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3604602 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3604603 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3604604 | 131064 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3604605 | 131064 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3604606 | 131064 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3604607 | 131064 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3604608 | 131064 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3604609 | 131064 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3604610 | 131064 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3604611 | 131064 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3604612 | 131064 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3604613 | 131064 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3604614 | 131064 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3604615 | 131064 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3604616 | 131064 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3604617 | 131064 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3604618 | 131064 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3604619 | 131064 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3604620 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3604621 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3604622 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3604623 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3604624 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3604625 | 131064 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3604626 | 131064 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3604627 | 131064 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3604628 | 131064 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3604629 | 131064 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3604630 | 131064 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3604631 | 131064 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3604632 | 131064 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3604633 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3604634 | 131064 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3604635 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3604636 | 131064 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3604637 | 131064 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3604638 | 131064 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3604639 | 131064 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3604640 | 131064 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3604641 | 131064 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3604642 | 131064 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3604643 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3604644 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3604645 | 131064 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3604646 | 131064 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3604647 | 131064 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3604648 | 131064 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3604649 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3604650 | 131064 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3604651 | 131064 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3604652 | 131064 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3604653 | 131064 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3604654 | 131064 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3604655 | 131064 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3604656 | 131064 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3604657 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3604658 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3604659 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3604660 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3604661 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3604662 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3604663 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3604664 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3604665 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3604666 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3604667 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3604668 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3604669 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3604670 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3604671 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3604672 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3604673 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3604674 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3604675 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3604676 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3604677 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3604678 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3604679 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3604680 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3604681 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3604682 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3604683 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3604684 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3604685 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3604686 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3604687 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3604688 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3604689 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3604690 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3604691 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3604692 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3604693 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3604694 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3604695 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3604696 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3604697 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3604698 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3604699 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3604700 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3604701 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3604702 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3604703 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3604704 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3604705 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3604706 | 131064 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3604707 | 131064 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3604708 | 131064 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3604709 | 131064 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3604710 | 131064 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3604711 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3604712 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3604713 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3604714 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3604715 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3604716 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3604717 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3604718 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3604719 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3604720 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3604721 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3604722 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3604723 | 131064 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3604724 | 131064 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3604725 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3604726 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3604727 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3604728 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3604729 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3604730 | 131064 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3604731 | 131064 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3604732 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3604733 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3604734 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3604735 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3604736 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3604737 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3604738 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3604739 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3604740 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3604741 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3604742 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3604743 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3604744 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3604745 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3604746 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3604747 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3604748 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3604749 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3604750 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3604751 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3604752 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3604753 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3604754 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3604755 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3604756 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3604757 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3604758 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3604759 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3604760 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3604761 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3604762 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3604763 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3604764 | 131064 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3604765 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3604766 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3604767 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3604768 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3604769 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3604770 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3604771 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3604772 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3604773 | 131064 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3604774 | 131064 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3604775 | 131064 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3604776 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3604777 | 131064 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3604778 | 131064 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3604779 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3604780 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3604781 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3604782 | 131064 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3604783 | 131064 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3604784 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3604785 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3604786 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3604787 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3604788 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3604789 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3604790 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3604791 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3604792 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3604793 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3604794 | 131064 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3604795 | 131064 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3604796 | 131064 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3604797 | 131064 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3604798 | 131064 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3604799 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3604800 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3604801 | 131064 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3604802 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3604803 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3604804 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3604805 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3604806 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3604807 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3604808 | 131064 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3604809 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3604810 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3604811 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3604812 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3604813 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3604814 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3604815 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3604816 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3604817 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3604818 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3604819 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3604820 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3604821 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3604822 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3604823 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3604824 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3604825 | 131064 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3604826 | 131064 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3604827 | 131064 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3604828 | 131064 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3604829 | 131064 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3604830 | 131064 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3604831 | 131064 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3604832 | 131064 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3604833 | 131064 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3604834 | 131064 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3604835 | 131064 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3604836 | 131064 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3604837 | 131064 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3604838 | 131064 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3604839 | 131064 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3604840 | 131064 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3604841 | 131064 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3604842 | 131064 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3604843 | 131064 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3604844 | 131064 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3604845 | 131064 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3604846 | 131064 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3604847 | 131064 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3604848 | 131064 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3604849 | 131064 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3604850 | 131064 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3604851 | 131064 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3604852 | 131064 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3604853 | 131064 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3604854 | 131064 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3604855 | 131064 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3604856 | 131064 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3604857 | 131064 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3604858 | 131064 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3604859 | 131064 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3604860 | 131064 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3604861 | 131064 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3604862 | 131064 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3604863 | 131064 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3604864 | 131064 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3604865 | 131064 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3604866 | 131064 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3604867 | 131064 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3604868 | 131064 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3604869 | 131064 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3604870 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3604871 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3604872 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3604873 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3604874 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3604875 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3604876 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3604877 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3604878 | 131064 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3604879 | 131064 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3604880 | 131064 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3604881 | 131064 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3604882 | 131064 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3604883 | 131064 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3604884 | 131064 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3604885 | 131064 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3604886 | 131064 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3604887 | 131064 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3604888 | 131064 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3604889 | 131064 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3604890 | 131064 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3604891 | 131064 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3604892 | 131064 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3604893 | 131064 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3604894 | 131064 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3604895 | 131064 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3604896 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3604897 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3604898 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3604899 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3604900 | 131064 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3604901 | 131064 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3604902 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3604903 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3604904 | 131064 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3604905 | 131064 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3604906 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3604907 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3604908 | 131064 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3604909 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3604910 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3604911 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3604912 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3604913 | 131064 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3604914 | 131064 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3604915 | 131064 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3604916 | 131064 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3604917 | 131064 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3604918 | 131064 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3604919 | 131064 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3604920 | 131064 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3604921 | 131064 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3604922 | 131064 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3604923 | 131064 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3604924 | 131064 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3604925 | 131064 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3604926 | 131064 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3604927 | 131064 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3604928 | 131064 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3604929 | 131064 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3604930 | 131064 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3604931 | 131064 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3604932 | 131064 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3604933 | 131064 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3604934 | 131064 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3604935 | 131064 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3604936 | 131064 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3604937 | 131064 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3604938 | 131064 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3604939 | 131064 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3604940 | 131064 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3604941 | 131064 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3604942 | 131064 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3604943 | 131064 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3604944 | 131064 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3604945 | 131064 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3604946 | 131064 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3604947 | 131064 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3604948 | 131064 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3604949 | 131064 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3604950 | 131064 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3604951 | 131064 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3604952 | 131064 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3604953 | 131064 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3604954 | 131064 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3604955 | 131064 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3604956 | 131064 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3604957 | 131064 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3604958 | 131064 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3604959 | 131064 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3604960 | 131064 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3604961 | 131064 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3604962 | 131064 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3604963 | 131064 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3604964 | 131064 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3604965 | 131064 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3604966 | 131064 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3604967 | 131064 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3604968 | 131064 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3604969 | 131064 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3604970 | 131064 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3604971 | 131064 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3604972 | 131064 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3604973 | 131064 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3604974 | 131064 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3604975 | 131064 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3604976 | 131064 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3604977 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3604978 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3604979 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3604980 | 131064 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3604981 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3604982 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3604983 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3604984 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3604985 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3604986 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3604987 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3604988 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3604989 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3604990 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3604991 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3604992 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3604993 | 131064 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3604994 | 131064 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3604995 | 131064 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3604996 | 131064 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3604997 | 131064 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3604998 | 131064 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3604999 | 131064 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3605000 | 131064 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3605001 | 131064 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3605002 | 131064 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3605003 | 131064 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3605004 | 131064 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3605005 | 131064 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3605006 | 131064 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3605007 | 131064 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3605008 | 131064 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3605009 | 131064 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3605010 | 131064 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3605011 | 131064 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3605012 | 131064 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3605013 | 131064 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3605014 | 131064 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3605015 | 131064 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3605016 | 131064 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3605017 | 131064 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3605018 | 131064 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3605019 | 131064 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3605020 | 131064 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3605021 | 131064 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3605022 | 131064 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3605023 | 131064 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3605024 | 131064 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3605025 | 131064 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3605026 | 131064 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3605027 | 131064 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3605028 | 131064 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3605029 | 131064 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3605030 | 131064 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3605031 | 131064 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3605032 | 131064 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3605033 | 131064 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3605034 | 131064 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3605035 | 131064 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3605036 | 131064 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3605037 | 131064 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3605038 | 131064 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3605039 | 131064 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3605040 | 131064 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3605041 | 131064 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3605042 | 131064 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3605043 | 131064 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3605044 | 131064 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3605045 | 131064 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3605046 | 131064 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3605047 | 131064 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3605048 | 131064 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3605049 | 131064 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3605050 | 131064 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3605051 | 131064 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3605052 | 131064 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3605053 | 131064 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3605054 | 131064 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3605055 | 131064 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3605056 | 131064 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3605057 | 131064 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3605058 | 131064 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3605059 | 131064 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3605060 | 131064 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3605061 | 131064 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3605062 | 131064 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3605063 | 131064 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3605064 | 131064 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3605065 | 131064 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3605066 | 131064 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3605067 | 131064 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3605068 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3605069 | 131064 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3605070 | 131064 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3605071 | 131064 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3605072 | 131064 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3605073 | 131064 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3605074 | 131064 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3605075 | 131064 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3605076 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3605077 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3605078 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3605079 | 131064 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3605080 | 131064 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3605081 | 131064 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3605082 | 131064 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3605083 | 131064 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3605084 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3605085 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3605086 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3605087 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3605088 | 131064 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3605089 | 131064 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3605090 | 131064 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3605091 | 131064 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3605092 | 131064 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3605093 | 131064 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3605094 | 131064 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3605095 | 131064 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3605096 | 131064 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3605097 | 131064 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3605098 | 131064 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3605099 | 131064 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3605100 | 131064 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3605101 | 131064 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3605102 | 131064 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3605103 | 131064 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3605104 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3605105 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3605106 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3605107 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3605108 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3605109 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3605110 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3605111 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3605112 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3605113 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3605114 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3605115 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3605116 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3605117 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3605118 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3605119 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3605120 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3605121 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3605122 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3605123 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3605124 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3605125 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3605126 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3605127 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3605128 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3605129 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3605130 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3605131 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3605132 | 131064 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3605133 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3605134 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3605135 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3605136 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3605137 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3605138 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3605139 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3605140 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3605141 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3605142 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3605143 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3605144 | 131064 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3605145 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3605146 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3605147 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3605148 | 131064 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3605149 | 131064 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3605150 | 131064 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3605151 | 131064 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3605152 | 131064 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3605153 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3605154 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3605155 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3605156 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3605157 | 131064 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3605158 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3605159 | 131064 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3605160 | 131064 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3605161 | 131064 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3605162 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3605163 | 131064 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3605164 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3605165 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3605166 | 131064 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3605167 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3605168 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3605169 | 131064 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3605170 | 131064 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3605171 | 131064 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
| 1721810362000 | 0 | None | None | Buildings | Construction of primary health centre at basapattana, in gangavathi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3605172 | 131065 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3605173 | 131065 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3605174 | 131065 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3605175 | 131065 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3605176 | 131065 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3605177 | 131065 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3605178 | 131065 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3605179 | 131065 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3605180 | 131065 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3605181 | 131065 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3605182 | 131065 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3605183 | 131065 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3605184 | 131065 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3605185 | 131065 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3605186 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3605187 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3605188 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3605189 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3605190 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3605191 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3605192 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3605193 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3605194 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3605195 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3605196 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3605197 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3605198 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3605199 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3605200 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3605201 | 131065 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3605202 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3605203 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3605204 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3605205 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3605206 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3605207 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3605208 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3605209 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3605210 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3605211 | 131065 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3605212 | 131065 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3605213 | 131065 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3605214 | 131065 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3605215 | 131065 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3605216 | 131065 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3605217 | 131065 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3605218 | 131065 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3605219 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3605220 | 131065 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3605221 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3605222 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3605223 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3605224 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3605225 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3605226 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3605227 | 131065 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3605228 | 131065 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3605229 | 131065 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3605230 | 131065 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3605231 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3605232 | 131065 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3605233 | 131065 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3605234 | 131065 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3605235 | 131065 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3605236 | 131065 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3605237 | 131065 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3605238 | 131065 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3605239 | 131065 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3605240 | 131065 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3605241 | 131065 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3605242 | 131065 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3605243 | 131065 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3605244 | 131065 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3605245 | 131065 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3605246 | 131065 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3605247 | 131065 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3605248 | 131065 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3605249 | 131065 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3605250 | 131065 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3605251 | 131065 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3605252 | 131065 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3605253 | 131065 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3605254 | 131065 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3605255 | 131065 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3605256 | 131065 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3605257 | 131065 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3605258 | 131065 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3605259 | 131065 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3605260 | 131065 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3605261 | 131065 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3605262 | 131065 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3605263 | 131065 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3605264 | 131065 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3605265 | 131065 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3605266 | 131065 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3605267 | 131065 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3605268 | 131065 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3605269 | 131065 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3605270 | 131065 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3605271 | 131065 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3605272 | 131065 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3605273 | 131065 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3605274 | 131065 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3605275 | 131065 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3605276 | 131065 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3605277 | 131065 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3605278 | 131065 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3605279 | 131065 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3605280 | 131065 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3605281 | 131065 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3605282 | 131065 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3605283 | 131065 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3605284 | 131065 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3605285 | 131065 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3605286 | 131065 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3605287 | 131065 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3605288 | 131065 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3605289 | 131065 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3605290 | 131065 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3605291 | 131065 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3605292 | 131065 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3605293 | 131065 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3605294 | 131065 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3605295 | 131065 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3605296 | 131065 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3605297 | 131065 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3605298 | 131065 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3605299 | 131065 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3605300 | 131065 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3605301 | 131065 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3605302 | 131065 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3605303 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3605304 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3605305 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3605306 | 131065 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3605307 | 131065 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3605308 | 131065 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3605309 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3605310 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3605311 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3605312 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3605313 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3605314 | 131065 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3605315 | 131065 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3605316 | 131065 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3605317 | 131065 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3605318 | 131065 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3605319 | 131065 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3605320 | 131065 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3605321 | 131065 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3605322 | 131065 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3605323 | 131065 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3605324 | 131065 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3605325 | 131065 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3605326 | 131065 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3605327 | 131065 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3605328 | 131065 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3605329 | 131065 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3605330 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3605331 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3605332 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3605333 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3605334 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3605335 | 131065 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3605336 | 131065 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3605337 | 131065 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3605338 | 131065 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3605339 | 131065 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3605340 | 131065 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3605341 | 131065 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3605342 | 131065 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3605343 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3605344 | 131065 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3605345 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3605346 | 131065 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3605347 | 131065 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3605348 | 131065 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3605349 | 131065 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3605350 | 131065 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3605351 | 131065 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3605352 | 131065 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3605353 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3605354 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3605355 | 131065 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3605356 | 131065 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3605357 | 131065 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3605358 | 131065 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3605359 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3605360 | 131065 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3605361 | 131065 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3605362 | 131065 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3605363 | 131065 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3605364 | 131065 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3605365 | 131065 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3605366 | 131065 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3605367 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3605368 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3605369 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3605370 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3605371 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3605372 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3605373 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3605374 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3605375 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3605376 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3605377 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3605378 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3605379 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3605380 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3605381 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3605382 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3605383 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3605384 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3605385 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3605386 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3605387 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3605388 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3605389 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3605390 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3605391 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3605392 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3605393 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3605394 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3605395 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3605396 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3605397 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3605398 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3605399 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3605400 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3605401 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3605402 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3605403 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3605404 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3605405 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3605406 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3605407 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3605408 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3605409 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3605410 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3605411 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3605412 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3605413 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3605414 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3605415 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3605416 | 131065 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3605417 | 131065 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3605418 | 131065 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3605419 | 131065 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3605420 | 131065 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3605421 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3605422 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3605423 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3605424 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3605425 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3605426 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3605427 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3605428 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3605429 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3605430 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3605431 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3605432 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3605433 | 131065 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3605434 | 131065 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3605435 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3605436 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3605437 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3605438 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3605439 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3605440 | 131065 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3605441 | 131065 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3605442 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3605443 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3605444 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3605445 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3605446 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3605447 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3605448 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3605449 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3605450 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3605451 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3605452 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3605453 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3605454 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3605455 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3605456 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3605457 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3605458 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3605459 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3605460 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3605461 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3605462 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3605463 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3605464 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3605465 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3605466 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3605467 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3605468 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3605469 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3605470 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3605471 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3605472 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3605473 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3605474 | 131065 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3605475 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3605476 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3605477 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3605478 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3605479 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3605480 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3605481 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3605482 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3605483 | 131065 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3605484 | 131065 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3605485 | 131065 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3605486 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3605487 | 131065 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3605488 | 131065 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3605489 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3605490 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3605491 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3605492 | 131065 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3605493 | 131065 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3605494 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3605495 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3605496 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3605497 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3605498 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3605499 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3605500 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3605501 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3605502 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3605503 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3605504 | 131065 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3605505 | 131065 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3605506 | 131065 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3605507 | 131065 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3605508 | 131065 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3605509 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3605510 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3605511 | 131065 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3605512 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3605513 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3605514 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3605515 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3605516 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3605517 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3605518 | 131065 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3605519 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3605520 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3605521 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3605522 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3605523 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3605524 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3605525 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3605526 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3605527 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3605528 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3605529 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3605530 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3605531 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3605532 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3605533 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3605534 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3605535 | 131065 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3605536 | 131065 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3605537 | 131065 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3605538 | 131065 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3605539 | 131065 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3605540 | 131065 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3605541 | 131065 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3605542 | 131065 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3605543 | 131065 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3605544 | 131065 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3605545 | 131065 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3605546 | 131065 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3605547 | 131065 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3605548 | 131065 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3605549 | 131065 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3605550 | 131065 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3605551 | 131065 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3605552 | 131065 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3605553 | 131065 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3605554 | 131065 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3605555 | 131065 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3605556 | 131065 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3605557 | 131065 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3605558 | 131065 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3605559 | 131065 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3605560 | 131065 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3605561 | 131065 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3605562 | 131065 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3605563 | 131065 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3605564 | 131065 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3605565 | 131065 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3605566 | 131065 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3605567 | 131065 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3605568 | 131065 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3605569 | 131065 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3605570 | 131065 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3605571 | 131065 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3605572 | 131065 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3605573 | 131065 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3605574 | 131065 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3605575 | 131065 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3605576 | 131065 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3605577 | 131065 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3605578 | 131065 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3605579 | 131065 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3605580 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3605581 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3605582 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3605583 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3605584 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3605585 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3605586 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3605587 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3605588 | 131065 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3605589 | 131065 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3605590 | 131065 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3605591 | 131065 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3605592 | 131065 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3605593 | 131065 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3605594 | 131065 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3605595 | 131065 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3605596 | 131065 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3605597 | 131065 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3605598 | 131065 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3605599 | 131065 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3605600 | 131065 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3605601 | 131065 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3605602 | 131065 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3605603 | 131065 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3605604 | 131065 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3605605 | 131065 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3605606 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3605607 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3605608 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3605609 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3605610 | 131065 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3605611 | 131065 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3605612 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3605613 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3605614 | 131065 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3605615 | 131065 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3605616 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3605617 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3605618 | 131065 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3605619 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3605620 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3605621 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3605622 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3605623 | 131065 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3605624 | 131065 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3605625 | 131065 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3605626 | 131065 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3605627 | 131065 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3605628 | 131065 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3605629 | 131065 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3605630 | 131065 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3605631 | 131065 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3605632 | 131065 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3605633 | 131065 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3605634 | 131065 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3605635 | 131065 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3605636 | 131065 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3605637 | 131065 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3605638 | 131065 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3605639 | 131065 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3605640 | 131065 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3605641 | 131065 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3605642 | 131065 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3605643 | 131065 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3605644 | 131065 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3605645 | 131065 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3605646 | 131065 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3605647 | 131065 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3605648 | 131065 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3605649 | 131065 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3605650 | 131065 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3605651 | 131065 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3605652 | 131065 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3605653 | 131065 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3605654 | 131065 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3605655 | 131065 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3605656 | 131065 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3605657 | 131065 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3605658 | 131065 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3605659 | 131065 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3605660 | 131065 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3605661 | 131065 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3605662 | 131065 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3605663 | 131065 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3605664 | 131065 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3605665 | 131065 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3605666 | 131065 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3605667 | 131065 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3605668 | 131065 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3605669 | 131065 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3605670 | 131065 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3605671 | 131065 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3605672 | 131065 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3605673 | 131065 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3605674 | 131065 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3605675 | 131065 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3605676 | 131065 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3605677 | 131065 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3605678 | 131065 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3605679 | 131065 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3605680 | 131065 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3605681 | 131065 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3605682 | 131065 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3605683 | 131065 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3605684 | 131065 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3605685 | 131065 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3605686 | 131065 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3605687 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3605688 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3605689 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3605690 | 131065 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3605691 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3605692 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3605693 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3605694 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3605695 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3605696 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3605697 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3605698 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3605699 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3605700 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3605701 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3605702 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3605703 | 131065 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3605704 | 131065 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3605705 | 131065 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3605706 | 131065 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3605707 | 131065 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3605708 | 131065 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3605709 | 131065 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3605710 | 131065 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3605711 | 131065 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3605712 | 131065 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3605713 | 131065 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3605714 | 131065 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3605715 | 131065 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3605716 | 131065 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3605717 | 131065 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3605718 | 131065 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3605719 | 131065 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3605720 | 131065 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3605721 | 131065 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3605722 | 131065 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3605723 | 131065 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3605724 | 131065 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3605725 | 131065 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3605726 | 131065 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3605727 | 131065 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3605728 | 131065 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3605729 | 131065 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3605730 | 131065 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3605731 | 131065 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3605732 | 131065 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3605733 | 131065 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3605734 | 131065 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3605735 | 131065 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3605736 | 131065 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3605737 | 131065 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3605738 | 131065 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3605739 | 131065 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3605740 | 131065 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3605741 | 131065 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3605742 | 131065 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3605743 | 131065 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3605744 | 131065 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3605745 | 131065 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3605746 | 131065 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3605747 | 131065 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3605748 | 131065 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3605749 | 131065 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3605750 | 131065 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3605751 | 131065 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3605752 | 131065 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3605753 | 131065 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3605754 | 131065 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3605755 | 131065 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3605756 | 131065 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3605757 | 131065 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3605758 | 131065 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3605759 | 131065 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3605760 | 131065 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3605761 | 131065 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3605762 | 131065 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3605763 | 131065 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3605764 | 131065 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3605765 | 131065 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3605766 | 131065 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3605767 | 131065 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3605768 | 131065 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3605769 | 131065 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3605770 | 131065 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3605771 | 131065 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3605772 | 131065 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3605773 | 131065 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3605774 | 131065 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3605775 | 131065 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3605776 | 131065 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3605777 | 131065 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3605778 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3605779 | 131065 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3605780 | 131065 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3605781 | 131065 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3605782 | 131065 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3605783 | 131065 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3605784 | 131065 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3605785 | 131065 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3605786 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3605787 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3605788 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3605789 | 131065 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3605790 | 131065 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3605791 | 131065 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3605792 | 131065 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3605793 | 131065 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3605794 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3605795 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3605796 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3605797 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3605798 | 131065 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3605799 | 131065 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3605800 | 131065 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3605801 | 131065 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3605802 | 131065 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3605803 | 131065 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3605804 | 131065 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3605805 | 131065 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3605806 | 131065 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3605807 | 131065 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3605808 | 131065 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3605809 | 131065 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3605810 | 131065 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3605811 | 131065 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3605812 | 131065 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3605813 | 131065 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3605814 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3605815 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3605816 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3605817 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3605818 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3605819 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3605820 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3605821 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3605822 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3605823 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3605824 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3605825 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3605826 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3605827 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3605828 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3605829 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3605830 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3605831 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3605832 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3605833 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3605834 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3605835 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3605836 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3605837 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3605838 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3605839 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3605840 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3605841 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3605842 | 131065 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3605843 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3605844 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3605845 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3605846 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3605847 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3605848 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3605849 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3605850 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3605851 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3605852 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3605853 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3605854 | 131065 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3605855 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3605856 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3605857 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3605858 | 131065 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3605859 | 131065 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3605860 | 131065 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3605861 | 131065 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3605862 | 131065 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3605863 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3605864 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3605865 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3605866 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3605867 | 131065 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3605868 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3605869 | 131065 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3605870 | 131065 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3605871 | 131065 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3605872 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3605873 | 131065 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3605874 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3605875 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3605876 | 131065 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3605877 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3605878 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3605879 | 131065 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3605880 | 131065 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3605881 | 131065 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
| 1721810362000 | 0 | None | None | Buildings | Construction of primary health centre at gouripura, in gangavathi taluka in koppala district | 35053667.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3605882 | 131066 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5A | upto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 15.91 | False | None | None | False | None | False | 7746.8972 | 0 | 3605883 | 131066 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth. | Cum | 117.7 | 117.7 | 477.3 | False | None | None | False | None | False | 56178.21 | 0 | 3605884 | 131066 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 454.299 | False | None | None | False | None | False | 57409.76463 | 0 | 3605885 | 131066 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 190.024 | False | None | None | False | None | False | 85463.294 | 0 | 3605886 | 131066 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 12.886 | False | None | None | False | None | False | 8844.9504 | 0 | 3605887 | 131066 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 7017.69 | 7017.69 | 126.605 | False | None | None | False | None | False | 888474.64245 | 0 | 3605888 | 131066 | None | PWD SR 2023-24 V-1I Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 891.0 | False | None | None | False | None | False | 130264.2 | 0 | 3605889 | 131066 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 454.299 | False | None | None | False | None | False | 149723.32143 | 0 | 3605890 | 131066 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.48 | 536.48 | 281.749 | False | None | None | False | None | False | 151152.70352 | 0 | 3605891 | 131066 | None | PWD SR 2023-24 V-I Page No-15 It No-2.2.3 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7850.3 | 7850.3 | 76.112 | False | None | None | False | None | False | 597502.0336 | 0 | 3605892 | 131066 | None | PWD SR 2023-24 V-I Page No-16 It No-2.4.3 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, | Cum | 7850.3 | 7850.3 | 19.152 | False | None | None | False | None | False | 150348.9456 | 0 | 3605893 | 131066 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 39.53 | False | None | None | False | None | False | 317375.3016 | 0 | 3605894 | 131066 | None | PWD SR 2023-24 V-I Page No-16 It No-2.3.2 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 20.7 | False | None | None | False | None | False | 166194.504 | 0 | 3605895 | 131066 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 13.44 | False | None | None | False | None | False | 1489652.2368 | 0 | 3605896 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 76.112 | False | None | None | False | None | False | 47799.85824 | 0 | 3605897 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 350.88 | 350.88 | 126.605 | False | None | None | False | None | False | 44423.1624 | 0 | 3605898 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% ) | Cum | 5495.21 | 5495.21 | 20.08 | False | None | None | False | None | False | 110343.8168 | 0 | 3605899 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 39.53 | False | None | None | False | None | False | 158687.6508 | 0 | 3605900 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-11 | Foundation upto PlinthForm Work and Centering
(Addendum - Vol-1, Page No -111)
( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% ) | Cum | 802.87 | 802.87 | 20.7 | False | None | None | False | None | False | 16619.409 | 0 | 3605901 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR . | Cum | 8478.47 | 8478.47 | 5.5 | False | None | None | False | None | False | 46631.585 | 0 | 3605902 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.132 | False | None | None | False | None | False | 1130.35032 | 0 | 3605903 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
RCC Sill -GROUND FLOOR | Cum | 8478.47 | 8478.47 | 0.715 | False | None | None | False | None | False | 6062.10605 | 0 | 3605904 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 0.022 | False | None | None | False | None | False | 188.39172 | 0 | 3605905 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOOR | Cum | 8478.47 | 8478.47 | 3.395 | False | None | None | False | None | False | 28784.40565 | 0 | 3605906 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOOR | Cum | 8478.47 | 8478.47 | 84.53 | False | None | None | False | None | False | 716685.0691 | 0 | 3605907 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 2.7 | False | None | None | False | None | False | 23120.802 | 0 | 3605908 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOOR | Cum | 8478.47 | 8478.47 | 42.11 | False | None | None | False | None | False | 357028.3717 | 0 | 3605909 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOOR | Cum | 8563.26 | 8563.26 | 1.66 | False | None | None | False | None | False | 14215.0116 | 0 | 3605910 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C Column | Cum | 8478.47 | 8478.47 | 25.17 | False | None | None | False | None | False | 213403.0899 | 0 | 3605911 | 131066 | None | PWD SR 2023-24 V- I Page No-16 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C Column | Cum | 8563.26 | 8563.26 | 8.86 | False | None | None | False | None | False | 75870.4836 | 0 | 3605912 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty GROUND FLOOR | Cum | 5934.93 | 5934.93 | 25.17 | False | None | None | False | None | False | 149382.1881 | 0 | 3605913 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Columns / Shaft (Slip Centering) ( 70% )
Columns Qty TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 8.86 | False | None | None | False | None | False | 53109.3208 | 0 | 3605914 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM GROUND FLOOR | Cum | 5087.08 | 5087.08 | 42.11 | False | None | None | False | None | False | 214216.9388 | 0 | 3605915 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)
BEAM TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.66 | False | None | None | False | None | False | 8528.997 | 0 | 3605916 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL GROUND FLOOR | Cum | 5087.08 | 5087.08 | 5.5 | False | None | None | False | None | False | 27978.94 | 0 | 3605917 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-14 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
LINTEL TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 0.132 | False | None | None | False | None | False | 678.2094 | 0 | 3605918 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof Slab GROUND FLOOR | Cum | 4239.23 | 4239.23 | 84.53 | False | None | None | False | None | False | 358342.1119 | 0 | 3605919 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
RCC Roof Slabs (50%) Roof SlabTERRACE FLOOR | Cum | 4281.63 | 4281.63 | 2.7 | False | None | None | False | None | False | 11560.401 | 0 | 3605920 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-16 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Staircase and other similar structures (50%)
Staircase GROUND FLOOR | Cum | 4239.23 | 4239.23 | 3.395 | False | None | None | False | None | False | 14392.18585 | 0 | 3605921 | 131066 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOOR | Cum | 3815.31 | 3815.31 | 0.715 | False | None | None | False | None | False | 2727.94665 | 0 | 3605922 | 131066 | None | PWD SR 2023-24 V1 Page No-112 It No-19 | Form Work and Centering
(Apendix - Vol-1, Page No -111)
(% On Finished Rate of Concrete per Cum)
Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.022 | False | None | None | False | None | False | 84.77612 | 0 | 3605923 | 131066 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOOR | t | 110837.22 | 110837.22 | 21.12 | False | None | None | False | None | False | 2340882.0864 | 0 | 3605924 | 131066 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)
TERRACE FLOOR | t | 111945.59 | 111945.59 | 2.3 | False | None | None | False | None | False | 257474.857 | 0 | 3605925 | 131066 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 9873.59 | 9873.59 | 247.82 | False | None | None | False | None | False | 2446873.0738 | 0 | 3605926 | 131066 | None | PWD SR 2023-24 V11 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 46.69 | False | None | None | False | None | False | 465607.6208 | 0 | 3605927 | 131066 | None | PWD SR 2023-24 V11 Page No-17 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth level up
to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including
cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Sqm | 1313.34 | 1313.34 | 118.68 | False | None | None | False | None | False | 155867.1912 | 0 | 3605928 | 131066 | None | PWD SR 2023-24 V11 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.168 | False | None | None | False | None | False | 20568.53904 | 0 | 3605929 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOOR | Sqm | 6145.44 | 6145.44 | 8.64 | False | None | None | False | None | False | 53096.6016 | 0 | 3605930 | 131066 | None | PWD SR 2023-24 V11 Page No-104 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Each | 1258.82 | 1258.82 | 12.0 | False | None | None | False | None | False | 15105.84 | 0 | 3605931 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOR | Each | 148.68 | 148.68 | 4.0 | False | None | None | False | None | False | 594.72 | 0 | 3605932 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOR | Each | 1380.24 | 1380.24 | 4.0 | False | None | None | False | None | False | 5520.96 | 0 | 3605933 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOR | Each | 1303.42 | 1303.42 | 2.0 | False | None | None | False | None | False | 2606.84 | 0 | 3605934 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOR | Each | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3605935 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOR | Each | 161.07 | 161.07 | 8.0 | False | None | None | False | None | False | 1288.56 | 0 | 3605936 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Each | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3605937 | 131066 | None | PWD SR 2023-24 V11 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOR | Each | 340.72 | 340.72 | 16.0 | False | None | None | False | None | False | 5451.52 | 0 | 3605938 | 131066 | None | PWD SR 2023-24 V11 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOR | Each | 358.07 | 358.07 | 2.0 | False | None | None | False | None | False | 716.14 | 0 | 3605939 | 131066 | None | PWD SR 2023-24 V11 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Each | 74.34 | 74.34 | 8.0 | False | None | None | False | None | False | 594.72 | 0 | 3605940 | 131066 | None | PWD SR 2023-24 V11 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | m | 64.42 | 64.42 | 16.8 | False | None | None | False | None | False | 1082.256 | 0 | 3605941 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 48.6 | False | None | None | False | None | False | 405490.212 | 0 | 3605942 | 131066 | None | PWD SR 2023-24 V11 Page No-105 It No-12.57.7 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3605943 | 131066 | None | PWD SR 2023-24 V11 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 2.88 | False | None | None | False | None | False | 20407.2192 | 0 | 3605944 | 131066 | None | PWD SR 2023-24 V11 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOOR | Sqm | 394.0 | 394.0 | 20.475 | False | None | None | False | None | False | 8067.15 | 0 | 3605945 | 131066 | None | PWD SR 2023-24 V11 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOOR | Sqm | 2931.47 | 2931.47 | 20.475 | False | None | None | False | None | False | 60021.84825 | 0 | 3605946 | 131066 | None | PWD SR 2023-24 V-2 Page No-111 It No-12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 7737.55 | 7737.55 | 40.95 | False | None | None | False | None | False | 316852.6725 | 0 | 3605947 | 131066 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 208.15 | 208.15 | 1081.08 | False | None | None | False | None | False | 225026.802 | 0 | 3605948 | 131066 | None | PWD SR 2023-24 V11 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3605949 | 131066 | None | PWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 618.26 | 618.26 | 37.8 | False | None | None | False | None | False | 23370.228 | 0 | 3605950 | 131066 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 61.95 | 61.95 | 51.48 | False | None | None | False | None | False | 3189.186 | 0 | 3605951 | 131066 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3605952 | 131066 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 206.91 | 206.91 | 51.48 | False | None | None | False | None | False | 10651.7268 | 0 | 3605953 | 131066 | None | PWD SR 2023-24 V11 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3605954 | 131066 | None | PWD SR 2023-24 V11 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.66 | 65.66 | 8.64 | False | None | None | False | None | False | 567.3024 | 0 | 3605955 | 131066 | None | PWD SR 2023-24 V11 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOOR | Sqm | 734.72 | 734.72 | 8.64 | False | None | None | False | None | False | 6347.9808 | 0 | 3605956 | 131066 | None | PWD SR 2023-24 V11 Page No-85 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 700.03 | 700.03 | 372.6 | False | None | None | False | None | False | 260831.178 | 0 | 3605957 | 131066 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOOR | Sqm | 261.42 | 261.42 | 155.7 | False | None | None | False | None | False | 40703.094 | 0 | 3605958 | 131066 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOOR | Sqm | 264.04 | 264.04 | 18.0 | False | None | None | False | None | False | 4752.72 | 0 | 3605959 | 131066 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 315.94 | 315.94 | 1940.212 | False | None | None | False | None | False | 612990.57928 | 0 | 3605960 | 131066 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 319.1 | 319.1 | 210.255 | False | None | None | False | None | False | 67092.3705 | 0 | 3605961 | 131066 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 453.47 | 453.47 | 491.752 | False | None | None | False | None | False | 222994.77944 | 0 | 3605962 | 131066 | None | PWD SR 2023-24 V11 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 458.0 | 458.0 | 212.955 | False | None | None | False | None | False | 97533.39 | 0 | 3605963 | 131066 | None | PWD SR 2023-24 V11 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 365.5 | 365.5 | 341.085 | False | None | None | False | None | False | 124666.5675 | 0 | 3605964 | 131066 | None | PWD SR 2023-24 V11 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 341.085 | False | None | None | False | None | False | 612353.31135 | 0 | 3605965 | 131066 | None | PWD SR 2023-24 V11 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1418.65 | 1418.65 | 472.6 | False | None | None | False | None | False | 670453.99 | 0 | 3605966 | 131066 | None | PWD SR 2023-24 V11 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 1101.47 | 1101.47 | 48.2 | False | None | None | False | None | False | 53090.854 | 0 | 3605967 | 131066 | None | PWD SR 2023-24 V11 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 6601.39 | 6601.39 | 26.45 | False | None | None | False | None | False | 174606.7655 | 0 | 3605968 | 131066 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4877.94 | 4877.94 | 13.0 | False | None | None | False | None | False | 63413.22 | 0 | 3605969 | 131066 | None | PWD SR 2023-24 V11 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOOR | Sqm | 4926.72 | 4926.72 | 1.0 | False | None | None | False | None | False | 4926.72 | 0 | 3605970 | 131066 | None | PWD SR 2023-24 V11 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3605971 | 131066 | None | PWD SR 2023-24 V11 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOOR | m | 732.24 | 732.24 | 2.4 | False | None | None | False | None | False | 1757.376 | 0 | 3605972 | 131066 | None | PWD SR 2023-24 V11 Page No-64 It No-9.29 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5335.13 | 5335.13 | 30.0 | False | None | None | False | None | False | 160053.9 | 0 | 3605973 | 131066 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.4 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOOR | Sqm | 1154.74 | 1154.74 | 18.5 | False | None | None | False | None | False | 21362.69 | 0 | 3605974 | 131066 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece.
GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 411.1 | False | None | None | False | None | False | 870993.459 | 0 | 3605975 | 131066 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 48.2 | False | None | None | False | None | False | 102120.858 | 0 | 3605976 | 131066 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOOR | Sqm | 123.9 | 123.9 | 1940.212 | False | None | None | False | None | False | 240392.2668 | 0 | 3605977 | 131066 | None | PWD SR 2023-24 V11 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOOR | Sqm | 125.13 | 125.13 | 210.255 | False | None | None | False | None | False | 26309.20815 | 0 | 3605978 | 131066 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 65.66 | 65.66 | 2095.912 | False | None | None | False | None | False | 137617.58192 | 0 | 3605979 | 131066 | None | PWD SR 2023-24 V11 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 66.32 | 66.32 | 228.255 | False | None | None | False | None | False | 15137.8716 | 0 | 3605980 | 131066 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 136.29 | 136.29 | 2095.912 | False | None | None | False | None | False | 285651.84648 | 0 | 3605981 | 131066 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
TERRACE FLOOR | Sqm | 137.65 | 137.65 | 228.255 | False | None | None | False | None | False | 31419.30075 | 0 | 3605982 | 131066 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 491.752 | False | None | None | False | None | False | 106011.89616 | 0 | 3605983 | 131066 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 217.74 | 217.74 | 212.955 | False | None | None | False | None | False | 46368.8217 | 0 | 3605984 | 131066 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOOR | Sqm | 767.0 | 767.0 | 540.0 | False | None | None | False | None | False | 414180.0 | 0 | 3605985 | 131066 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 876.0 | False | None | None | False | None | False | 71630.52 | 0 | 3605986 | 131066 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | m | 42.12 | 42.12 | 1278.0 | False | None | None | False | None | False | 53829.36 | 0 | 3605987 | 131066 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOOR | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3605988 | 131066 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | m | 9.91 | 9.91 | 148.8 | False | None | None | False | None | False | 1474.608 | 0 | 3605989 | 131066 | None | PWD SR V11 Page No-44 It No-8.16.4( SR 2021-22) | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
TERRACE FLOOR | m | 10.01 | 10.01 | 4.8 | False | None | None | False | None | False | 48.048 | 0 | 3605990 | 131066 | None | Approved Rate 1 | Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units.
The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system. | Sqm | 2522.6 | 2522.6 | 55.0 | False | None | None | False | None | False | 138743.0 | 0 | 3605991 | 131066 | None | Approved Rate 2 | Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification. | Sqm | 967.6 | 967.6 | 52.0 | False | None | None | False | None | False | 50315.2 | 0 | 3605992 | 131066 | None | Approved Rate 3 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Scrub Door /Dirty utility Door (Double leaf)
1.5 mtr X 2.10 mtr
Say 3.15 Sq.mt | Sqm | 53843.4 | 53843.4 | 6.3 | False | None | None | False | None | False | 339213.42 | 0 | 3605993 | 131066 | None | Approved Rate 4 | Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be used | Sqm | 3304.0 | 3304.0 | 55.0 | False | None | None | False | None | False | 181720.0 | 0 | 3605994 | 131066 | None | Approved Rate 5 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories. | Nos | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3605995 | 131066 | None | Approved Rate 6 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. | Nos | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3605996 | 131066 | None | Approved Rate 7 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. | Nos | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 | 3605997 | 131066 | None | Approved Rate 8 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. | Nos | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 3605998 | 131066 | None | Approved Rate 9 | Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch. | Nos | 287535.32 | 287535.32 | 1.0 | False | None | None | False | None | False | 287535.32 | 0 | 3605999 | 131066 | None | Approved Rate 10 | Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc complete | Nos | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3606000 | 131066 | None | PWD SR 2023-24 V2 Page No-131 It No-14.3.1 | WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOR | Each | 7405.5 | 7405.5 | 11.0 | False | None | None | False | None | False | 81460.5 | 0 | 3606001 | 131066 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOR | Each | 2183.0 | 2183.0 | 11.0 | False | None | None | False | None | False | 24013.0 | 0 | 3606002 | 131066 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOR | Each | 5518.5 | 5518.5 | 3.0 | False | None | None | False | None | False | 16555.5 | 0 | 3606003 | 131066 | None | PWD SR 2023-24 V-2 Page No-123 It No-14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOR | Each | 753.31 | 753.31 | 11.0 | False | None | None | False | None | False | 8286.41 | 0 | 3606004 | 131066 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOR | Each | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3606005 | 131066 | None | PWD SR 2023-24 V-2 Page No-70 It No-10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOOR | Sqm | 3455.57 | 3455.57 | 2.88 | False | None | None | False | None | False | 9952.0416 | 0 | 3606006 | 131066 | None | PWD SR 2023-24 V11 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOR | Each | 3173.07 | 3173.07 | 5.0 | False | None | None | False | None | False | 15865.35 | 0 | 3606007 | 131066 | None | Approved Rate | Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOR | Each | 8873.6 | 8873.6 | 5.0 | False | None | None | False | None | False | 44368.0 | 0 | 3606008 | 131066 | None | PWD SR 2023-24 V-2 Page No-134 It No-14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOOR | Nos. | 6296.59 | 6296.59 | 2.0 | False | None | None | False | None | False | 12593.18 | 0 | 3606009 | 131066 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOOR | Nos. | 2275.04 | 2275.04 | 2.0 | False | None | None | False | None | False | 4550.08 | 0 | 3606010 | 131066 | None | PWD SR 2023-24 V11 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOR | Each | 614.54 | 614.54 | 10.0 | False | None | None | False | None | False | 6145.4 | 0 | 3606011 | 131066 | None | PWD SR 2023-24 V11 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOR | Each | 250.27 | 250.27 | 21.0 | False | None | None | False | None | False | 5255.67 | 0 | 3606012 | 131066 | None | PWD SR 2023-24 V11 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOR | Each | 1003.59 | 1003.59 | 12.0 | False | None | None | False | None | False | 12043.08 | 0 | 3606013 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOR | Each | 1261.3 | 1261.3 | 10.0 | False | None | None | False | None | False | 12613.0 | 0 | 3606014 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOR | Each | 58.23 | 58.23 | 10.0 | False | None | None | False | None | False | 582.3 | 0 | 3606015 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOOR | m | 113.98 | 113.98 | 12.0 | False | None | None | False | None | False | 1367.76 | 0 | 3606016 | 131066 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOOR | m | 358.07 | 358.07 | 37.0 | False | None | None | False | None | False | 13248.59 | 0 | 3606017 | 131066 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | 110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOOR | m | 477.01 | 477.01 | 26.0 | False | None | None | False | None | False | 12402.26 | 0 | 3606018 | 131066 | None | PWD SR 2023-24 V11 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 360.54 | 360.54 | 20.0 | False | None | None | False | None | False | 7210.8 | 0 | 3606019 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOOR | m | 469.58 | 469.58 | 40.0 | False | None | None | False | None | False | 18783.2 | 0 | 3606020 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 591.0 | 591.0 | 43.0 | False | None | None | False | None | False | 25413.0 | 0 | 3606021 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes
Cold Water Supply GROUND FLOOR | m | 690.12 | 690.12 | 6.0 | False | None | None | False | None | False | 4140.72 | 0 | 3606022 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOOR | m | 591.0 | 591.0 | 20.0 | False | None | None | False | None | False | 11820.0 | 0 | 3606023 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tank | m | 902.25 | 902.25 | 107.0 | False | None | None | False | None | False | 96540.75 | 0 | 3606024 | 131066 | None | PWD SR 2023-24 V11 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOOR | Nos. | 1511.58 | 1511.58 | 5.0 | False | None | None | False | None | False | 7557.9 | 0 | 3606025 | 131066 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 11.26 | 11.26 | 2000.0 | False | None | None | False | None | False | 22520.0 | 0 | 3606026 | 131066 | None | PWD SR 2023-24 V11 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOOR | Nos. | 123.9 | 123.9 | 10.0 | False | None | None | False | None | False | 1239.0 | 0 | 3606027 | 131066 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3606028 | 131066 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHT | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3606029 | 131066 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 1877.08 | 1877.08 | 7.0 | False | None | None | False | None | False | 13139.56 | 0 | 3606030 | 131066 | None | PWD SR 2023-24 V-5 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2112.34 | 2112.34 | 2.0 | False | None | None | False | None | False | 4224.68 | 0 | 3606031 | 131066 | None | PWD SR 2023-24 V-5 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle Flanges | No. | 1977.19 | 1977.19 | 2.0 | False | None | None | False | None | False | 3954.38 | 0 | 3606032 | 131066 | None | PWD SR 2023-24 V11 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOOR | Nos. | 387.8 | 387.8 | 20.0 | False | None | None | False | None | False | 7756.0 | 0 | 3606033 | 131066 | None | Old Sr 2018- 19 Page No- It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
GROUND FLOOR | Nos | 18746.07 | 18746.07 | 5.0 | False | None | None | False | None | False | 93730.35 | 0 | 3606034 | 131066 | None | PWD SR 2023-24 V11 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOOR | Nos. | 6990.43 | 6990.43 | 10.0 | False | None | None | False | None | False | 69904.3 | 0 | 3606035 | 131066 | None | PWD SR 2023-24 V11 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 3197.85 | 3197.85 | 10.0 | False | None | None | False | None | False | 31978.5 | 0 | 3606036 | 131066 | None | Approved Rate 1 | Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOOR | Nos | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3606037 | 131066 | None | Approved Rate 2 | 1354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hr | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3606038 | 131066 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Sqm | 299.83 | 299.83 | 40.5 | False | None | None | False | None | False | 12143.115 | 0 | 3606039 | 131066 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 40.5 | False | None | None | False | None | False | 12996.45 | 0 | 3606040 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 10.56 | False | None | None | False | None | False | 13109.9232 | 0 | 3606041 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 10.56 | False | None | None | False | None | False | 15517.392 | 0 | 3606042 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 10.56 | False | None | None | False | None | False | 15595.8528 | 0 | 3606043 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge. | Cum | 1659.02 | 1659.02 | 37.114 | False | None | None | False | None | False | 61572.86828 | 0 | 3606044 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.6.3 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm | m | 2325.6 | 2325.6 | 6.0 | False | None | None | False | None | False | 13953.6 | 0 | 3606045 | 131066 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.8 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | hr | 1147.31 | 1147.31 | 32.0 | False | None | None | False | None | False | 36713.92 | 0 | 3606046 | 131066 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.9.3 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia | Each | 314.7 | 314.7 | 6.0 | False | None | None | False | None | False | 1888.2 | 0 | 3606047 | 131066 | None | PWD SR 2023-24 V-1I Page No-176 It No-17.11.3 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom
of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia | Each | 354.35 | 354.35 | 6.0 | False | None | None | False | None | False | 2126.1 | 0 | 3606048 | 131066 | None | Approved Rate | Providing and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC rings | Each | 1121.0 | 1121.0 | 30.0 | False | None | None | False | None | False | 33630.0 | 0 | 3606049 | 131066 | None | Data Rate | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slab | Sqm | 1796.55 | 1796.55 | 10.621 | False | None | None | False | None | False | 19081.15755 | 0 | 3606050 | 131066 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | SEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3606051 | 131066 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3606052 | 131066 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3606053 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3606054 | 131066 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.467 | False | None | None | False | None | False | 5995.03029 | 0 | 3606055 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3606056 | 131066 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.77 | False | None | None | False | None | False | 196181.8794 | 0 | 3606057 | 131066 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3606058 | 131066 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3606059 | 131066 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3606060 | 131066 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3606061 | 131066 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3606062 | 131066 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3606063 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3606064 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3606065 | 131066 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 | 3606066 | 131066 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | SUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3606067 | 131066 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3606068 | 131066 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3606069 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3606070 | 131066 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3606071 | 131066 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3606072 | 131066 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3606073 | 131066 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3606074 | 131066 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3606075 | 131066 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3606076 | 131066 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 | 3606077 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 10.0 | False | None | None | False | None | False | 3174.2 | 0 | 3606078 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 22.0 | False | None | None | False | None | False | 9838.84 | 0 | 3606079 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 60.0 | False | None | None | False | None | False | 39294.0 | 0 | 3606080 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 16.0 | False | None | None | False | None | False | 12781.76 | 0 | 3606081 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 10.0 | False | None | None | False | None | False | 11670.2 | 0 | 3606082 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 Way | Each | 121.54 | 121.54 | 2.0 | False | None | None | False | None | False | 243.08 | 0 | 3606083 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way | Each | 146.32 | 146.32 | 2.0 | False | None | None | False | None | False | 292.64 | 0 | 3606084 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5Way | Each | 161.66 | 161.66 | 3.0 | False | None | None | False | None | False | 484.98 | 0 | 3606085 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 | 3606086 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way | Each | 258.42 | 258.42 | 2.0 | False | None | None | False | None | False | 516.84 | 0 | 3606087 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 Way | Each | 162.84 | 162.84 | 18.0 | False | None | None | False | None | False | 2931.12 | 0 | 3606088 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 Way | Each | 187.62 | 187.62 | 30.0 | False | None | None | False | None | False | 5628.6 | 0 | 3606089 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 208.86 | 208.86 | 22.0 | False | None | None | False | None | False | 4594.92 | 0 | 3606090 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 259.6 | 259.6 | 38.0 | False | None | None | False | None | False | 9864.8 | 0 | 3606091 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 307.98 | 307.98 | 26.0 | False | None | None | False | None | False | 8007.48 | 0 | 3606092 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3606093 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 Way | Each | 428.34 | 428.34 | 6.0 | False | None | None | False | None | False | 2570.04 | 0 | 3606094 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 Module | Each | 161.66 | 161.66 | 20.0 | False | None | None | False | None | False | 3233.2 | 0 | 3606095 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 Module | Each | 189.98 | 189.98 | 32.0 | False | None | None | False | None | False | 6079.36 | 0 | 3606096 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 206.5 | 206.5 | 25.0 | False | None | None | False | None | False | 5162.5 | 0 | 3606097 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 276.12 | 276.12 | 42.0 | False | None | None | False | None | False | 11597.04 | 0 | 3606098 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 335.12 | 335.12 | 28.0 | False | None | None | False | None | False | 9383.36 | 0 | 3606099 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3606100 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 Module | Each | 468.46 | 468.46 | 6.0 | False | None | None | False | None | False | 2810.76 | 0 | 3606101 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 120.36 | 120.36 | 210.0 | False | None | None | False | None | False | 25275.6 | 0 | 3606102 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 195.88 | 195.88 | 10.0 | False | None | None | False | None | False | 1958.8 | 0 | 3606103 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 201.78 | 201.78 | 108.0 | False | None | None | False | None | False | 21792.24 | 0 | 3606104 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 421.26 | 421.26 | 40.0 | False | None | None | False | None | False | 16850.4 | 0 | 3606105 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 38.0 | False | None | None | False | None | False | 10582.24 | 0 | 3606106 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 38.0 | False | None | None | False | None | False | 8071.2 | 0 | 3606107 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 6.0 | False | None | None | False | None | False | 2308.08 | 0 | 3606108 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3606109 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bell | Each | 290.28 | 290.28 | 2.0 | False | None | None | False | None | False | 580.56 | 0 | 3606110 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 40.0 | False | None | None | False | None | False | 9298.4 | 0 | 3606111 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 40.0 | False | None | None | False | None | False | 5522.4 | 0 | 3606112 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thick | m | 77.88 | 77.88 | 1150.0 | False | None | None | False | None | False | 89562.0 | 0 | 3606113 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 1350.0 | False | None | None | False | None | False | 124254.0 | 0 | 3606114 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 265.0 | False | None | None | False | None | False | 32208.1 | 0 | 3606115 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 210.0 | False | None | None | False | None | False | 16850.4 | 0 | 3606116 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 350.0 | False | None | None | False | None | False | 32627.0 | 0 | 3606117 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 40.0 | False | None | None | False | None | False | 4672.8 | 0 | 3606118 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction box | Each | 57.82 | 57.82 | 110.0 | False | None | None | False | None | False | 6360.2 | 0 | 3606119 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction box | Each | 66.08 | 66.08 | 160.0 | False | None | None | False | None | False | 10572.8 | 0 | 3606120 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction box | Each | 71.98 | 71.98 | 20.0 | False | None | None | False | None | False | 1439.6 | 0 | 3606121 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mm | m | 30.68 | 30.68 | 1750.0 | False | None | None | False | None | False | 53690.0 | 0 | 3606122 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 2480.0 | False | None | None | False | None | False | 122908.8 | 0 | 3606123 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mm | m | 74.34 | 74.34 | 950.0 | False | None | None | False | None | False | 70623.0 | 0 | 3606124 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 280.0 | False | None | None | False | None | False | 30396.8 | 0 | 3606125 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mm | m | 197.06 | 197.06 | 160.0 | False | None | None | False | None | False | 31529.6 | 0 | 3606126 | 131066 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 220.0 | False | None | None | False | None | False | 778.8 | 0 | 3606127 | 131066 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 310.0 | False | None | None | False | None | False | 1463.2 | 0 | 3606128 | 131066 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 80.0 | False | None | None | False | None | False | 660.8 | 0 | 3606129 | 131066 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 24.0 | False | None | None | False | None | False | 198.24 | 0 | 3606130 | 131066 | None | MR 5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 9.44 | 9.44 | 18.0 | False | None | None | False | None | False | 169.92 | 0 | 3606131 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4764.84 | 4764.84 | 3.0 | False | None | None | False | None | False | 14294.52 | 0 | 3606132 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & N | Each | 5829.2 | 5829.2 | 2.0 | False | None | None | False | None | False | 11658.4 | 0 | 3606133 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 3.0 | False | None | None | False | None | False | 8244.66 | 0 | 3606134 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SP | Each | 489.7 | 489.7 | 86.0 | False | None | None | False | None | False | 42114.2 | 0 | 3606135 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3606136 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPN | Each | 3643.84 | 3643.84 | 6.0 | False | None | None | False | None | False | 21863.04 | 0 | 3606137 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 pole | Each | 5379.62 | 5379.62 | 3.0 | False | None | None | False | None | False | 16138.86 | 0 | 3606138 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 pole | Each | 6543.1 | 6543.1 | 2.0 | False | None | None | False | None | False | 13086.2 | 0 | 3606139 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.17.3 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way | Each | 18324.22 | 18324.22 | 1.0 | False | None | None | False | None | False | 18324.22 | 0 | 3606140 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.15.9 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3606141 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63A | Each | 4953.58 | 4953.58 | 1.0 | False | None | None | False | None | False | 4953.58 | 0 | 3606142 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.5.3 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour. 100A | Each | 8934.28 | 8934.28 | 2.0 | False | None | None | False | None | False | 17868.56 | 0 | 3606143 | 131066 | None | MR 6 | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 548.7 | 548.7 | 20.0 | False | None | None | False | None | False | 10974.0 | 0 | 3606144 | 131066 | None | MR 7 | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | m | 719.8 | 719.8 | 25.0 | False | None | None | False | None | False | 17995.0 | 0 | 3606145 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.3.1 | TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 650.18 | 650.18 | 4.0 | False | None | None | False | None | False | 2600.72 | 0 | 3606146 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 50.0 | False | None | None | False | None | False | 40710.0 | 0 | 3606147 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 12.0 | False | None | None | False | None | False | 12531.6 | 0 | 3606148 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 34.0 | False | None | None | False | None | False | 53118.88 | 0 | 3606149 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.6.3 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36W | No | 5372.54 | 5372.54 | 12.0 | False | None | None | False | None | False | 64470.48 | 0 | 3606150 | 131066 | None | MR 8 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 12.0 | False | None | None | False | None | False | 6372.0 | 0 | 3606151 | 131066 | None | MR 9 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3606152 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 10.0 | False | None | None | False | None | False | 17605.6 | 0 | 3606153 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 40.0 | False | None | None | False | None | False | 126354.4 | 0 | 3606154 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 112.0 | False | None | None | False | None | False | 16123.52 | 0 | 3606155 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 40.0 | False | None | None | False | None | False | 8071.2 | 0 | 3606156 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 10.0 | False | None | None | False | None | False | 5805.6 | 0 | 3606157 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 210000.0 | False | None | None | False | None | False | 123900.0 | 0 | 3606158 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 7.0 | False | None | None | False | None | False | 28373.1 | 0 | 3606159 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3606160 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.51.3 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATS | Each | 109922.9 | 109922.9 | 1.0 | False | None | None | False | None | False | 109922.9 | 0 | 3606161 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.15.15 | Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kA | Each | 27783.1 | 27783.1 | 1.0 | False | None | None | False | None | False | 27783.1 | 0 | 3606162 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 10.0 | False | None | None | False | None | False | 12508.0 | 0 | 3606163 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 10.0 | False | None | None | False | None | False | 36438.4 | 0 | 3606164 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.15.10 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kA | Each | 12202.38 | 12202.38 | 6.0 | False | None | None | False | None | False | 73214.28 | 0 | 3606165 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kA | Each | 15867.46 | 15867.46 | 2.0 | False | None | None | False | None | False | 31734.92 | 0 | 3606166 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3606167 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3606168 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3606169 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3606170 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3606171 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3606172 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3606173 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 60.0 | False | None | None | False | None | False | 1840.8 | 0 | 3606174 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3606175 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2 | m | 375.24 | 375.24 | 55.0 | False | None | None | False | None | False | 20638.2 | 0 | 3606176 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.42.2 | APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 115000.0 | False | None | None | False | None | False | 67850.0 | 0 | 3606177 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 25535.2 | 25535.2 | 1.0 | False | None | None | False | None | False | 25535.2 | 0 | 3606178 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.40.2 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3606179 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole Incomers | Each | 15867.46 | 15867.46 | 1.0 | False | None | None | False | None | False | 15867.46 | 0 | 3606180 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.46.4 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP | Each | 946.36 | 946.36 | 8.0 | False | None | None | False | None | False | 7570.88 | 0 | 3606181 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 10.0 | False | None | None | False | None | False | 3599.0 | 0 | 3606182 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.4.2 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAR | Each | 252.52 | 252.52 | 4.0 | False | None | None | False | None | False | 1010.08 | 0 | 3606183 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.4.3 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR | Each | 405.92 | 405.92 | 1.0 | False | None | None | False | None | False | 405.92 | 0 | 3606184 | 131066 | None | MR 10 | ILPB Type push button with Lanmp - ON/OFF(L&T Make) | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3606185 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A | Each | 1522.2 | 1522.2 | 6.0 | False | None | None | False | None | False | 9133.2 | 0 | 3606186 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3606187 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3606188 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3606189 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2 | m | 30.68 | 30.68 | 40.0 | False | None | None | False | None | False | 1227.2 | 0 | 3606190 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2 | m | 49.56 | 49.56 | 45.0 | False | None | None | False | None | False | 2230.2 | 0 | 3606191 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2 | m | 74.34 | 74.34 | 35.0 | False | None | None | False | None | False | 2601.9 | 0 | 3606192 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2 | m | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3606193 | 131066 | None | PWD SR 2023-24 Volume 6 It No-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core. | Km | 167373.56 | 167373.56 | 0.1 | False | None | None | False | None | False | 16737.356 | 0 | 3606194 | 131066 | None | PWD SR 2023-24 Volume 6 It No-32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core. | Km | 181793.16 | 181793.16 | 0.04 | False | None | None | False | None | False | 7271.7264 | 0 | 3606195 | 131066 | None | PWD SR 2023-24 Volume 6 It No-32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core. | Km | 440393.7 | 440393.7 | 0.12 | False | None | None | False | None | False | 52847.244 | 0 | 3606196 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Core | m | 375.24 | 375.24 | 60.0 | False | None | None | False | None | False | 22514.4 | 0 | 3606197 | 131066 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.14 | False | None | None | False | None | False | 3450.3672 | 0 | 3606198 | 131066 | None | PWD SR 2023-24 Volume 6 It No-21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.12 | False | None | None | False | None | False | 4409.2824 | 0 | 3606199 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mm | Each | 80.24 | 80.24 | 10.0 | False | None | None | False | None | False | 802.4 | 0 | 3606200 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm dia | Each | 99.12 | 99.12 | 8.0 | False | None | None | False | None | False | 792.96 | 0 | 3606201 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm dia | Each | 138.06 | 138.06 | 8.0 | False | None | None | False | None | False | 1104.48 | 0 | 3606202 | 131066 | None | PWD SR 2023-24 Volume 6 It No-63.02 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | No | 48.38 | 48.38 | 18.0 | False | None | None | False | None | False | 870.84 | 0 | 3606203 | 131066 | None | PWD SR 2023-24 Volume 6 It No-63.05 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 156.94 | 156.94 | 18.0 | False | None | None | False | None | False | 2824.92 | 0 | 3606204 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound. | Each | 5343.04 | 5343.04 | 2.0 | False | None | None | False | None | False | 10686.08 | 0 | 3606205 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.60.3 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound. | Each | 10022.92 | 10022.92 | 2.0 | False | None | None | False | None | False | 20045.84 | 0 | 3606206 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 6.0 | False | None | None | False | None | False | 24850.8 | 0 | 3606207 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5022.08 | 5022.08 | 4.0 | False | None | None | False | None | False | 20088.32 | 0 | 3606208 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI strip | m | 151.04 | 151.04 | 120.0 | False | None | None | False | None | False | 18124.8 | 0 | 3606209 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 6.0 | False | None | None | False | None | False | 6195.0 | 0 | 3606210 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper strip | m | 672.6 | 672.6 | 50.0 | False | None | None | False | None | False | 33630.0 | 0 | 3606211 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3606212 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.18.3 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 22.42 | 22.42 | 110.0 | False | None | None | False | None | False | 2466.2 | 0 | 3606213 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire. | m | 123.9 | 123.9 | 220.0 | False | None | None | False | None | False | 27258.0 | 0 | 3606214 | 131066 | None | MR 11 | CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets. | Nos. | 17700.0 | 17700.0 | 6.0 | False | None | None | False | None | False | 106200.0 | 0 | 3606215 | 131066 | None | MR 12 | Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Nos. | 25960.0 | 25960.0 | 3.0 | False | None | None | False | None | False | 77880.0 | 0 | 3606216 | 131066 | None | MR 13 | NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz. | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3606217 | 131066 | None | MR 14 | 4TB HDD (Surveillance or Enterprise Grade) | Nos. | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3606218 | 131066 | None | MR 15 | 16 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Nos. | 23600.0 | 23600.0 | 1.0 | False | None | None | False | None | False | 23600.0 | 0 | 3606219 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.12.6 | Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panel | Nos. | 9145.0 | 9145.0 | 1.0 | False | None | None | False | None | False | 9145.0 | 0 | 3606220 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Nos. | 303.26 | 303.26 | 13.0 | False | None | None | False | None | False | 3942.38 | 0 | 3606221 | 131066 | None | MR 16 | Rj 45 connector with Crimping with 4 x 4 PVC boxes | Set | 192.34 | 192.34 | 11.0 | False | None | None | False | None | False | 2115.74 | 0 | 3606222 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.4.3 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depth | Nos. | 10001.68 | 10001.68 | 1.0 | False | None | None | False | None | False | 10001.68 | 0 | 3606223 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Nos. | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3606224 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Nos. | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3606225 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Nos. | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3606226 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 265.0 | False | None | None | False | None | False | 24390.6 | 0 | 3606227 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 390.0 | False | None | None | False | None | False | 17487.6 | 0 | 3606228 | 131066 | None | MR 17 | Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required) | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 3606229 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3606230 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 320.0 | False | None | None | False | None | False | 7929.6 | 0 | 3606231 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.4.4 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depth | Nos. | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3606232 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.9.10 | Supplying fixing of Networking Switches 24 Port 10/100/1000 Switch | Each | 8749.7 | 8749.7 | 1.0 | False | None | None | False | None | False | 8749.7 | 0 | 3606233 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.5 | Supplying & Fixing of Power strip | Each | 1719.26 | 1719.26 | 1.0 | False | None | None | False | None | False | 1719.26 | 0 | 3606234 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.6 | Supplying of shelf | Each | 975.86 | 975.86 | 1.0 | False | None | None | False | None | False | 975.86 | 0 | 3606235 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.8 | Supplying & Fixing of Fan | Each | 1426.62 | 1426.62 | 1.0 | False | None | None | False | None | False | 1426.62 | 0 | 3606236 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.10.1 | Supplying &fixing of I/Osocket, face plate with back box Single I/O | Each | 578.2 | 578.2 | 8.0 | False | None | None | False | None | False | 4625.6 | 0 | 3606237 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.10.2 | Supplying &fixing of I/Osocket, face plate with back box Double I/O | Each | 649.0 | 649.0 | 15.0 | False | None | None | False | None | False | 9735.0 | 0 | 3606238 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable | Each | 303.26 | 303.26 | 22.0 | False | None | None | False | None | False | 6671.72 | 0 | 3606239 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable | Each | 390.58 | 390.58 | 22.0 | False | None | None | False | None | False | 8592.76 | 0 | 3606240 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.12.5 | Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panel | Each | 9322.0 | 9322.0 | 1.0 | False | None | None | False | None | False | 9322.0 | 0 | 3606241 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.11 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3606242 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.3 | Supplying and drawing PVC insulated gas injected physical
foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 180.0 | False | None | None | False | None | False | 9345.6 | 0 | 3606243 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOX | Each | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3606244 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | m | 92.04 | 92.04 | 450.0 | False | None | None | False | None | False | 41418.0 | 0 | 3606245 | 131066 | None | MR 18 | Supply & Fixing of GbESpeed Wifi Router, PoE Support. | Each | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3606246 | 131066 | None | MR 19 | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 17700.0 | 17700.0 | 1.0 | False | None | None | False | None | False | 17700.0 | 0 | 3606247 | 131066 | None | MR 20 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue Extensions | Nos | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3606248 | 131066 | None | MR 21 | 10 line IPM with LED Indications | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 3606249 | 131066 | None | MR 22 | Analog Phones | Nos | 2065.0 | 2065.0 | 15.0 | False | None | None | False | None | False | 30975.0 | 0 | 3606250 | 131066 | None | MR 23 | Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A. | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 3606251 | 131066 | None | MR 24 | Supply & Fixing of PC , T & A Software, | Nos | 64900.0 | 64900.0 | 1.0 | False | None | None | False | None | False | 64900.0 | 0 | 3606252 | 131066 | None | PWD SR 2023-24 Volume 6 It No-8.1 | Supplying and drawing UTP-CAT 6E LAN cable | Nos | 44.84 | 44.84 | 50.0 | False | None | None | False | None | False | 2242.0 | 0 | 3606253 | 131066 | None | CSR 23-24 Page No-20 It No-45.04 | EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4417.92 | 4417.92 | 6.0 | False | None | None | False | None | False | 26507.52 | 0 | 3606254 | 131066 | None | CSR 23-24 Page No-20 It No-45.07 | Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE Cable | Set | 4799.06 | 4799.06 | 2.0 | False | None | None | False | None | False | 9598.12 | 0 | 3606255 | 131066 | None | CSR 23-24 Page No-52 It No-22.04 | Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 Sqmm | No | 3136.44 | 3136.44 | 8.0 | False | None | None | False | None | False | 25091.52 | 0 | 3606256 | 131066 | None | CSR 23-24 Page No-15 It No-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1049805.88 | 1049805.88 | 0.12 | False | None | None | False | None | False | 125976.7056 | 0 | 3606257 | 131066 | None | CSR 23-24 Page No-52 It No-21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 72359.96 | 72359.96 | 0.12 | False | None | None | False | None | False | 8683.1952 | 0 | 3606258 | 131066 | None | CSR 23-24 Page No-16 It No-39.01 | Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing) | Unit | 648469.0 | 648469.0 | 1.0 | False | None | None | False | None | False | 648469.0 | 0 | 3606259 | 131066 | None | CSR 23-24 Page No-26 It No-58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 287296.96 | 287296.96 | 1.0 | False | None | None | False | None | False | 287296.96 | 0 | 3606260 | 131066 | None | CSR 23-24 Page No-23 It No-53.1 | HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT features | No | 16344.18 | 16344.18 | 3.0 | False | None | None | False | None | False | 49032.54 | 0 | 3606261 | 131066 | None | CSR 23-24 Page No-23 It No-53.02 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering) | No | 23558.7 | 23558.7 | 3.0 | False | None | None | False | None | False | 70676.1 | 0 | 3606262 | 131066 | None | CSR 23-24 Page No-17 It No-41.01 | Load Break Switch with Panel | No | 86422.02 | 86422.02 | 1.0 | False | None | None | False | None | False | 86422.02 | 0 | 3606263 | 131066 | None | CSR 23-24 Page No-7 It No-12.16 | Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPE | No | 268217.54 | 268217.54 | 1.0 | False | None | None | False | None | False | 268217.54 | 0 | 3606264 | 131066 | None | CSR 21-22 Page No-2 0f 14 It No-4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | No | 35825.98 | 35825.98 | 2.0 | False | None | None | False | None | False | 71651.96 | 0 | 3606265 | 131066 | None | CSR 21-22 Page No-22 It No-4.06 a) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs | No | 1732.24 | 1732.24 | 4.0 | False | None | None | False | None | False | 6928.96 | 0 | 3606266 | 131066 | None | CSR 21-22 Page No-4 of 4 It No-4.06 b) | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete
Minimum Weight of GI Pipe: 7.3 Kgs Rod Type | Set | 3418.46 | 3418.46 | 4.0 | False | None | None | False | None | False | 13673.84 | 0 | 3606267 | 131066 | None | Chapter-12 Page No-55 It No-12.60.3 | Using 10ft. Copper bonded rod with backfill compound. | No | 10022.92 | 10022.92 | 4.0 | False | None | None | False | None | False | 40091.68 | 0 | 3606268 | 131066 | None | CSR 21-22 Page No-22 It No-51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 797.68 | 797.68 | 12.0 | False | None | None | False | None | False | 9572.16 | 0 | 3606269 | 131066 | None | CSR 21-22 Page No-22 It No-51.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 365.8 | 365.8 | 12.0 | False | None | None | False | None | False | 4389.6 | 0 | 3606270 | 131066 | None | CSR 23-24 Page No-23 It No-51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2562.96 | 2562.96 | 10.0 | False | None | None | False | None | False | 25629.6 | 0 | 3606271 | 131066 | None | CSR 23-24 Page No-23 It No-51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 434.24 | 434.24 | 10.0 | False | None | None | False | None | False | 4342.4 | 0 | 3606272 | 131066 | None | CSR 23-24 Page No-23 It No-55.01 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | No | 610.06 | 610.06 | 5.0 | False | None | None | False | None | False | 3050.3 | 0 | 3606273 | 131066 | None | Page No-43 It No-1.6.1 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | No | 895.62 | 895.62 | 10.0 | False | None | None | False | None | False | 8956.2 | 0 | 3606274 | 131066 | None | Page No-43 It No-1.6.2 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | No | 3528.2 | 3528.2 | 4.0 | False | None | None | False | None | False | 14112.8 | 0 | 3606275 | 131066 | None | Chapter-5 Page No-20 It No-5.42.1 | Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.59 | 0.59 | 35000.0 | False | None | None | False | None | False | 20650.0 | 0 | 3606276 | 131066 | None | Chapter-5 Page No-20 It No-5.40.2 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Strips | m | 4053.3 | 4053.3 | 4.0 | False | None | None | False | None | False | 16213.2 | 0 | 3606277 | 131066 | None | Chapter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 654.9 | 654.9 | 12.0 | False | None | None | False | None | False | 7858.8 | 0 | 3606278 | 131066 | None | Chapter-5 Page No-17 It No-5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KA | Each | 25241.38 | 25241.38 | 1.0 | False | None | None | False | None | False | 25241.38 | 0 | 3606279 | 131066 | None | Chapter-5 Page No-17 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3606280 | 131066 | None | Chapter-5 Page No-18 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS Connectivity | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3606281 | 131066 | None | Chapter-5 Page No-19 It No-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3606282 | 131066 | None | Chapter-5 Page No-18 It No-5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3606283 | 131066 | None | Chapter-5 Page No-18 It No-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3606284 | 131066 | None | Chapter-5 Page No-18 It No-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CT | Each | 566.4 | 566.4 | 3.0 | False | None | None | False | None | False | 1699.2 | 0 | 3606285 | 131066 | None | Chapter-5 Page No-19 It No-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter | Each | 236.0 | 236.0 | 2.0 | False | None | None | False | None | False | 472.0 | 0 | 3606286 | 131066 | None | Chapter-5 Page No-19 It No-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter | Each | 188.8 | 188.8 | 2.0 | False | None | None | False | None | False | 377.6 | 0 | 3606287 | 131066 | None | Chapter-2 Page No-5 It No-2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3606288 | 131066 | None | Chapter-2 Page No-5 It No-2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 49.56 | 49.56 | 10.0 | False | None | None | False | None | False | 495.6 | 0 | 3606289 | 131066 | None | Least Quotation Rate | Supplying, fixing and wiring 3 Phase TVSS | Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3606290 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.01 | Cable Covering Tile 125x250x40 mm | Per Km | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3606291 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.02 | Cable Covering Tile 125x125x40 mm | Per Km | 5900.0 | 5900.0 | 1.0 | False | None | None | False | None | False | 5900.0 | 0 | 3606292 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.03 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 354.0 | 354.0 | 8.0 | False | None | None | False | None | False | 2832.0 | 0 | 3606293 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.04 | RCC Hume Pipe 2000 mm long 200 mm Dia | No | 448.4 | 448.4 | 10.0 | False | None | None | False | None | False | 4484.0 | 0 | 3606294 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.05 | Collars for RCC Hume Pipe 150 mm Dia | No | 94.4 | 94.4 | 4.0 | False | None | None | False | None | False | 377.6 | 0 | 3606295 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.06 | Collars for RCC Hume Pipe 200 mm Dia | No | 118.0 | 118.0 | 4.0 | False | None | None | False | None | False | 472.0 | 0 | 3606296 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.19 | Route & Joint indicating slab with MS Anchor rod | No | 153.4 | 153.4 | 5.0 | False | None | None | False | None | False | 767.0 | 0 | 3606297 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 5.0 | False | None | None | False | None | False | 749.3 | 0 | 3606298 | 131066 | None | CSR 21-22 Page No-23 of 27 It No-66.21 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 138.06 | 138.06 | 5.0 | False | None | None | False | None | False | 690.3 | 0 | 3606299 | 131066 | None | Page No-3 of 4 It No-XXV | Spiral Earth Electrode | Set | 375.24 | 375.24 | 15.0 | False | None | None | False | None | False | 5628.6 | 0 | 3606300 | 131066 | None | Page No-3 of 4 It No-XXVII | Caution/Danger Board | No | 234.82 | 234.82 | 2.0 | False | None | None | False | None | False | 469.64 | 0 | 3606301 | 131066 | None | Chpter-12 Page No-54 It No-12.58.2 | 25x3mm GI strip | m | 96.76 | 96.76 | 80.0 | False | None | None | False | None | False | 7740.8 | 0 | 3606302 | 131066 | None | Chpter-12 Page No-54 It No-12.58.3 | 25x6mm GI strip | m | 151.04 | 151.04 | 60.0 | False | None | None | False | None | False | 9062.4 | 0 | 3606303 | 131066 | None | Chpter-12 Page No-55 It No-12.58.6 | 600x600x3mm GI Plate | Each | 1032.5 | 1032.5 | 10.0 | False | None | None | False | None | False | 10325.0 | 0 | 3606304 | 131066 | None | Chpter-12 Page No-55 It No-12.58.7 | 25x3mm Copper strip | m | 672.6 | 672.6 | 60.0 | False | None | None | False | None | False | 40356.0 | 0 | 3606305 | 131066 | None | Chpter-12 Page No-55 It No-12.58.11 | 600x600x3mm Copper plate | Each | 8756.78 | 8756.78 | 4.0 | False | None | None | False | None | False | 35027.12 | 0 | 3606306 | 131066 | None | Least Quotation Rate 1 | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | m | 1593.0 | 1593.0 | 30.0 | False | None | None | False | None | False | 47790.0 | 0 | 3606307 | 131066 | None | Least Quotation Rate 2 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour, | Sqm | 1003.0 | 1003.0 | 10.0 | False | None | None | False | None | False | 10030.0 | 0 | 3606308 | 131066 | None | Chpter-5 Page No-20 It No-5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm | m | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3606309 | 131066 | None | Least Quotation Rate 3 | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 826.0 | 826.0 | 16.0 | False | None | None | False | None | False | 13216.0 | 0 | 3606310 | 131066 | None | Least Quotation Rate 4 | Supplying of two bucket stand alongwith buckets. Complete | Each | 743.4 | 743.4 | 2.0 | False | None | None | False | None | False | 1486.8 | 0 | 3606311 | 131066 | None | Least Quotation Rate 5 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 | 3606312 | 131066 | None | CSR 21-22 Page No- It No-21 OF 27 | Supplying of first aid box. Complete | Each | 1300.36 | 1300.36 | 2.0 | False | None | None | False | None | False | 2600.72 | 0 | 3606313 | 131066 | None | Least Quotation Rate 7 | Supplying of FIRST AID CHART with lamination. Complete | Each | 265.5 | 265.5 | 2.0 | False | None | None | False | None | False | 531.0 | 0 | 3606314 | 131066 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | UPS Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3606315 | 131066 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 | 3606316 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.9.5 | HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 Ph | No | 166680.9 | 166680.9 | 2.0 | False | None | None | False | None | False | 333361.8 | 0 | 3606317 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.13.2 | Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | m | 2080.34 | 2080.34 | 20.0 | False | None | None | False | None | False | 41606.8 | 0 | 3606318 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 5877.58 | 5877.58 | 2.0 | False | None | None | False | None | False | 11755.16 | 0 | 3606319 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.22 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. | Each | 5398.5 | 5398.5 | 2.0 | False | None | None | False | None | False | 10797.0 | 0 | 3606320 | 131066 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3606321 | 131066 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3606322 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3606323 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3606324 | 131066 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3606325 | 131066 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3606326 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3606327 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3606328 | 131066 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3606329 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3606330 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3606331 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3606332 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 | 3606333 | 131066 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | CC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.05 | False | None | None | False | None | False | 511.266 | 0 | 3606334 | 131066 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 31.5 | False | None | None | False | None | False | 3707.55 | 0 | 3606335 | 131066 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 31.5 | False | None | None | False | None | False | 4097.835 | 0 | 3606336 | 131066 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 31.5 | False | None | None | False | None | False | 18499.32 | 0 | 3606337 | 131066 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 15.75 | False | None | None | False | None | False | 46034.1 | 0 | 3606338 | 131066 | None | PWDSR 2023-24 V-3 Page No-49 It No6.1 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. | Cum | 6095.88 | 6095.88 | 10.5 | False | None | None | False | None | False | 64006.74 | 0 | 3606339 | 131066 | None | PWDSR 2023-24 V-3 Page No-43 (7) It No6.2 | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing | Cum | 11107.63 | 11107.63 | 21.0 | False | None | None | False | None | False | 233260.23 | 0 | 3606340 | 131066 | None | PageNo56 It No-8.10 MoRTH 803 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 105.31 | 105.31 | 15.0 | False | None | None | False | None | False | 1579.65 | 0 | 3606341 | 131066 | None | PageNo123 It No-13.14MoRTH 800 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 87.96 | 87.96 | 448.0 | False | None | None | False | None | False | 39406.08 | 0 | 3606342 | 131066 | None | PWD SR 2023-24 V-3 Page No-146 It No-21A(6.1) | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone | m | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3606343 | 131066 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.25 | False | None | None | False | None | False | 16695.8325 | 0 | 3606344 | 131066 | None | PWD Volume- 2 SR 2023-24 Page No-6 It No-1.5 | COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 77.15 | False | None | None | False | None | False | 28580.989 | 0 | 3606345 | 131066 | None | PWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 13.64 | False | None | None | False | None | False | 101213.8468 | 0 | 3606346 | 131066 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing Concrete | Cum | 8412.76 | 8412.76 | 8.7 | False | None | None | False | None | False | 73191.012 | 0 | 3606347 | 131066 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column Concrete | Cum | 13242.31 | 13242.31 | 8.02 | False | None | None | False | None | False | 106203.3262 | 0 | 3606348 | 131066 | None | PWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam Concrete | Cum | 13242.31 | 13242.31 | 8.01 | False | None | None | False | None | False | 106070.9031 | 0 | 3606349 | 131066 | None | PWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | t | 110837.22 | 110837.22 | 2.55 | False | None | None | False | None | False | 282634.911 | 0 | 3606350 | 131066 | None | PWD Volume- 2 SR 2023-24 Page No-17 It No-6.33 | roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1525.21 | 1525.21 | 137.58 | False | None | None | False | None | False | 209838.3918 | 0 | 3606351 | 131066 | None | PWD Volume- 2 SR 2023-24 Page No-42 It No-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 370.16 | False | None | None | False | None | False | 170151.4472 | 0 | 3606352 | 131066 | None | PWD Volume- 2 SR 2023-24 Page No-46 It No-8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 370.16 | False | None | None | False | None | False | 71544.5248 | 0 | 3606353 | 131066 | None | PWD SR 2023-24 V-5 Page No-140 It No-12.4 | BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3606354 | 131066 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrs | m | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3606355 | 131066 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr. | m | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3606356 | 131066 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr. | m | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3606357 | 131066 | None | PWD SR 2023-24 V-5 Page No-139 It No-12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr. | m | 708.71 | 708.71 | 30.0 | False | None | None | False | None | False | 21261.3 | 0 | 3606358 | 131066 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3606359 | 131066 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3606360 | 131066 | None | PWD SR 2023-24 V-5 Page No-143 It No-12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3606361 | 131066 | None | PWD SR 2023-24 V-5 Page No-154 It No-12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3606362 | 131066 | None | PWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3606363 | 131066 | None | PWD SR 2023-24 V-5 Page No-154 It No-13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" | Nos | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3606364 | 131066 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Nos | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3606365 | 131066 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3606366 | 131066 | None | PWD SR 2023-24 V-5 Page No-155 It No-13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3606367 | 131066 | None | PWD SR 2023-24 V-5 Page No-156 It No-13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3606368 | 131066 | None | PWD SR 2023 24 V 5 Page No-156 It No 13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3606369 | 131066 | None | PWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | m | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3606370 | 131066 | None | PWD SR 2023-24 V-5 Page No-20 It No-5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3606371 | 131066 | None | PWD SR 2023-24 V-5 Page No-21 It No-5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm. | Nos | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3606372 | 131066 | None | PWD SR 2023-24 Vol-6 It No-I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Nos | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3606373 | 131066 | None | PWD SR 2023-24 Vol-6 It No-I No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Nos | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3606374 | 131066 | None | PWD SR 2023-24 Vol-6 It No-I No 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Nos | 2230.2 | 2230.2 | 1.0 | False | None | None | False | None | False | 2230.2 | 0 | 3606375 | 131066 | None | PWD SR 2023-24 Vol-6 It No-I No. 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Nos | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 | 3606376 | 131066 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.1 | RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM Dia | Cum | 299.83 | 299.83 | 6.786 | False | None | None | False | None | False | 2034.64638 | 0 | 3606377 | 131066 | None | PWD SR 2023-24 V-1 Page No-5 It No-1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM Dia | Cum | 320.9 | 320.9 | 6.786 | False | None | None | False | None | False | 2177.6274 | 0 | 3606378 | 131066 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM Dia | Each | 1391.39 | 1391.39 | 28.0 | False | None | None | False | None | False | 38958.92 | 0 | 3606379 | 131066 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1241.47 | 1241.47 | 1.131 | False | None | None | False | None | False | 1404.10257 | 0 | 3606380 | 131066 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1469.45 | 1469.45 | 0.565 | False | None | None | False | None | False | 830.23925 | 0 | 3606381 | 131066 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM Dia | Cum | 1476.88 | 1476.88 | 0.565 | False | None | None | False | None | False | 834.4372 | 0 | 3606382 | 131066 | None | PWD SR 2023-24 V-2 Page No-175 It No-17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM Dia | Cum | 1659.02 | 1659.02 | 0.565 | False | None | None | False | None | False | 937.3463 | 0 | 3606383 | 131066 | None | PWD SR 2023-24 V-2 Page No-177 It No-17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM Dia | Sqm | 1449.63 | 1449.63 | 4.0 | False | None | None | False | None | False | 5798.52 | 0 | 3606384 | 131066 | None | PWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)A | NQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 1.0 | False | None | None | False | None | False | 486.92 | 0 | 3606385 | 131066 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 15.0 | False | None | None | False | None | False | 1765.5 | 0 | 3606386 | 131066 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 88.155 | False | None | None | False | None | False | 11140.14735 | 0 | 3606387 | 131066 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.75 | 449.75 | 22.038 | False | None | None | False | None | False | 9911.5905 | 0 | 3606388 | 131066 | None | PWD SR 2023-24 V-1 Page No-9 It No-1.16.1 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 686.4 | 686.4 | 2.203 | False | None | None | False | None | False | 1512.1392 | 0 | 3606389 | 131066 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 15.807 | False | None | None | False | None | False | 117293.78859 | 0 | 3606390 | 131066 | None | PWD SR 2023-24 V-2 Page No-5 It No-4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 82.0 | False | None | None | False | None | False | 11988.4 | 0 | 3606391 | 131066 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 88.155 | False | None | None | False | None | False | 29053.24335 | 0 | 3606392 | 131066 | None | PWD SR 2023-24 V-1 Page No-7 It No-1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 536.48 | 536.48 | 11.18 | False | None | None | False | None | False | 5997.8464 | 0 | 3606393 | 131066 | None | PWD SR 2023-24 V-1 Page No-15 It No-2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC ) | Cum | 7850.3 | 7850.3 | 13.85 | False | None | None | False | None | False | 108726.655 | 0 | 3606394 | 131066 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) | Cum | 7850.3 | 7850.3 | 2.88 | False | None | None | False | None | False | 22608.864 | 0 | 3606395 | 131066 | None | PWD SR 2023-24 V-1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) | Cum | 8028.72 | 8028.72 | 7.66 | False | None | None | False | None | False | 61499.9952 | 0 | 3606396 | 131066 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings) | t | 110837.22 | 110837.22 | 2.5 | False | None | None | False | None | False | 277093.05 | 0 | 3606397 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-1 | Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%) | Cum | 628.02 | 628.02 | 13.85 | False | None | None | False | None | False | 8698.077 | 0 | 3606398 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-3 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%) | Cum | 371.01 | 371.01 | 15.807 | False | None | None | False | None | False | 5864.55507 | 0 | 3606399 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-9 | Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) | Cum | 5495.21 | 5495.21 | 2.88 | False | None | None | False | None | False | 15826.2048 | 0 | 3606400 | 131066 | None | PWD SR 2023-24 V-1 Page No-111 It No-2 | Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%) | Cum | 4014.36 | 4014.36 | 7.66 | False | None | None | False | None | False | 30749.9976 | 0 | 3606401 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.24 | False | None | None | False | None | False | 10513.3028 | 0 | 3606402 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.17 | False | None | None | False | None | False | 1455.7542 | 0 | 3606403 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.65 | False | None | None | False | None | False | 5511.0055 | 0 | 3606404 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.1 | False | None | None | False | None | False | 856.326 | 0 | 3606405 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 1.872 | False | None | None | False | None | False | 15871.69584 | 0 | 3606406 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 0.445 | False | None | None | False | None | False | 3772.91915 | 0 | 3606407 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 0.06 | False | None | None | False | None | False | 513.7956 | 0 | 3606408 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 11.811 | False | None | None | False | None | False | 100139.20917 | 0 | 3606409 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.196 | False | None | None | False | None | False | 10241.65896 | 0 | 3606410 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 7.65 | False | None | None | False | None | False | 64860.2955 | 0 | 3606411 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 1.45 | False | None | None | False | None | False | 12416.727 | 0 | 3606412 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR) | Cum | 8478.47 | 8478.47 | 4.13 | False | None | None | False | None | False | 35016.0811 | 0 | 3606413 | 131066 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.5.2 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR) | Cum | 8563.26 | 8563.26 | 2.42 | False | None | None | False | None | False | 20723.0892 | 0 | 3606414 | 131066 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%)
GROUND FLOOR | Cum | 5934.93 | 5934.93 | 4.13 | False | None | None | False | None | False | 24511.2609 | 0 | 3606415 | 131066 | None | PWD SR 2023-24 V- 1 Page No-111 It No-9 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOOR | Cum | 5994.28 | 5994.28 | 2.42 | False | None | None | False | None | False | 14506.1576 | 0 | 3606416 | 131066 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOOR | Cum | 5087.08 | 5087.08 | 8.89 | False | None | None | False | None | False | 45224.1412 | 0 | 3606417 | 131066 | None | PWD SR 2023-24 V- 1 Page No-112 It No-14 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOOR | Cum | 5137.95 | 5137.95 | 1.62 | False | None | None | False | None | False | 8323.479 | 0 | 3606418 | 131066 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
GROUND FLOOR | Cum | 4239.23 | 4239.23 | 11.811 | False | None | None | False | None | False | 50069.54553 | 0 | 3606419 | 131066 | None | PWD SR 2023-24 V- 1 Page No-112 It No-15 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
RCC Roof Slabs (50%)
TERRACE FLOOR | Cum | 4281.63 | 4281.63 | 1.196 | False | None | None | False | None | False | 5120.82948 | 0 | 3606420 | 131066 | None | PWD SR 2023-24 V- 1 Page No-112 It No-16 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Staircase and other similar structures(50%) GROUND FLOOR | Cum | 4239.23 | 4239.23 | 1.872 | False | None | None | False | None | False | 7935.83856 | 0 | 3606421 | 131066 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )GROUND FLOOR | Cum | 3815.31 | 3815.31 | 1.09 | False | None | None | False | None | False | 4158.6879 | 0 | 3606422 | 131066 | None | PWD SR 2023-24 V- 1 Page No-112 It No-19 | Form Work and Centering
( % On Finished Rate of Concrete per cum)
Chejjas, Canopy & Other Architectural projections of
minor sections ( 45% )TERRACE FLOOR | Cum | 3853.46 | 3853.46 | 0.16 | False | None | None | False | None | False | 616.5536 | 0 | 3606423 | 131066 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOOR | t | 110837.22 | 110837.22 | 3.06 | False | None | None | False | None | False | 339161.8932 | 0 | 3606424 | 131066 | None | PWD SR 2023-24 V- 1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOOR | t | 111945.59 | 111945.59 | 0.75 | False | None | None | False | None | False | 83959.1925 | 0 | 3606425 | 131066 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOOR | Cum | 9873.59 | 9873.59 | 26.03 | False | None | None | False | None | False | 257009.5477 | 0 | 3606426 | 131066 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOOR | Cum | 9972.32 | 9972.32 | 12.79 | False | None | None | False | None | False | 127545.9728 | 0 | 3606427 | 131066 | None | PWD SR 2023-24 V-2 Page No-14 It No-6.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1313.34 | 1313.34 | 9.147 | False | None | None | False | None | False | 12013.12098 | 0 | 3606428 | 131066 | None | PWD SR 2023-24 V-2 Page No-100 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.78 | 122431.78 | 0.143 | False | None | None | False | None | False | 17507.74454 | 0 | 3606429 | 131066 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.95 | 4115.95 | 8.82 | False | None | None | False | None | False | 36302.679 | 0 | 3606430 | 131066 | None | PWD SR 2023-24 V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 4.0 | False | None | None | False | None | False | 5035.28 | 0 | 3606431 | 131066 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 5.0 | False | None | None | False | None | False | 743.4 | 0 | 3606432 | 131066 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1380.24 | 1380.24 | 5.0 | False | None | None | False | None | False | 6901.2 | 0 | 3606433 | 131066 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.6 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1303.42 | 1303.42 | 4.0 | False | None | None | False | None | False | 5213.68 | 0 | 3606434 | 131066 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 293.64 | 293.64 | 8.0 | False | None | None | False | None | False | 2349.12 | 0 | 3606435 | 131066 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 10.0 | False | None | None | False | None | False | 1610.7 | 0 | 3606436 | 131066 | None | PWD SR 2023-24 V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.14 | 68.14 | 4.0 | False | None | None | False | None | False | 272.56 | 0 | 3606437 | 131066 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):. | Nos | 340.72 | 340.72 | 20.0 | False | None | None | False | None | False | 6814.4 | 0 | 3606438 | 131066 | None | PWD SR 2023-24 V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm | Nos | 358.07 | 358.07 | 4.0 | False | None | None | False | None | False | 1432.28 | 0 | 3606439 | 131066 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | Nos | 74.34 | 74.34 | 16.0 | False | None | None | False | None | False | 1189.44 | 0 | 3606440 | 131066 | None | PWD SR 2023-24 V-2 Page No-205 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | m | 64.42 | 64.42 | 22.2 | False | None | None | False | None | False | 1430.124 | 0 | 3606441 | 131066 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8343.42 | 8343.42 | 12.24 | False | None | None | False | None | False | 102123.4608 | 0 | 3606442 | 131066 | None | PWD SR 2023-24 V-2 Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOOR | Sqm | 8426.86 | 8426.86 | 1.8 | False | None | None | False | None | False | 15168.348 | 0 | 3606443 | 131066 | None | PWD SR 2023-24 V-2 Page No-109 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 7085.84 | 7085.84 | 0.72 | False | None | None | False | None | False | 5101.8048 | 0 | 3606444 | 131066 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOOR | Sqm | 394.0 | 394.0 | 3.15 | False | None | None | False | None | False | 1241.1 | 0 | 3606445 | 131066 | None | PWD SR 2023-24 V-2 Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOOR | Sqm | 2931.47 | 2931.47 | 3.15 | False | None | None | False | None | False | 9234.1305 | 0 | 3606446 | 131066 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 208.15 | 208.15 | 272.16 | False | None | None | False | None | False | 56650.104 | 0 | 3606447 | 131066 | None | PWD SR 2023-24 V-2 Page No-86 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR | Kg | 210.23 | 210.23 | 37.8 | False | None | None | False | None | False | 7946.694 | 0 | 3606448 | 131066 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 61.95 | 61.95 | 12.96 | False | None | None | False | None | False | 802.872 | 0 | 3606449 | 131066 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 62.56 | 62.56 | 1.8 | False | None | None | False | None | False | 112.608 | 0 | 3606450 | 131066 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 206.91 | 206.91 | 12.96 | False | None | None | False | None | False | 2681.5536 | 0 | 3606451 | 131066 | None | PWD SR 2023-24 V-2 Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 208.98 | 208.98 | 1.8 | False | None | None | False | None | False | 376.164 | 0 | 3606452 | 131066 | None | PWD SR 2023-24 V-2 Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 65.66 | 65.66 | 8.82 | False | None | None | False | None | False | 579.1212 | 0 | 3606453 | 131066 | None | PWD SR 2023-24 V-2 Page No-54 It No-8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.
4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR | Sqm | 838.8 | 838.8 | 8.82 | False | None | None | False | None | False | 7398.216 | 0 | 3606454 | 131066 | None | PWD SR 2023-24 V-2 Page No-84 It No-11.26.3 | Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOOR | Kg | 226.73 | 226.73 | 168.0 | False | None | None | False | None | False | 38090.64 | 0 | 3606455 | 131066 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 261.42 | 261.42 | 42.0 | False | None | None | False | None | False | 10979.64 | 0 | 3606456 | 131066 | None | PWD SR 2023-24 V-2 Page No-43 It No-8.1 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 3606457 | 131066 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 315.94 | 315.94 | 235.785 | False | None | None | False | None | False | 74493.9129 | 0 | 3606458 | 131066 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 319.1 | 319.1 | 60.6 | False | None | None | False | None | False | 19337.46 | 0 | 3606459 | 131066 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 453.47 | 453.47 | 120.42 | False | None | None | False | None | False | 54606.8574 | 0 | 3606460 | 131066 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | Sqm | 458.0 | 458.0 | 56.1 | False | None | None | False | None | False | 25693.8 | 0 | 3606461 | 131066 | None | PWD SR 2023-24 V-2 Page No-41 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | Sqm | 365.5 | 365.5 | 40.8 | False | None | None | False | None | False | 14912.4 | 0 | 3606462 | 131066 | None | PWD SR 2023-24 V-2 Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 1795.31 | 1795.31 | 40.8 | False | None | None | False | None | False | 73248.648 | 0 | 3606463 | 131066 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1418.65 | 1418.65 | 79.55 | False | None | None | False | None | False | 112853.6075 | 0 | 3606464 | 131066 | None | PWD SR 2023-24 V-2 Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR . | Sqm | 1101.47 | 1101.47 | 6.87 | False | None | None | False | None | False | 7567.0989 | 0 | 3606465 | 131066 | None | PWD SR 2023-24 V-2 Page No-64 It No-9.3 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR . | Sqm | 6601.39 | 6601.39 | 16.44 | False | None | None | False | None | False | 108526.8516 | 0 | 3606466 | 131066 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR) | Sqm | 4877.94 | 4877.94 | 6.0 | False | None | None | False | None | False | 29267.64 | 0 | 3606467 | 131066 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOOR | m | 406.39 | 406.39 | 5.0 | False | None | None | False | None | False | 2031.95 | 0 | 3606468 | 131066 | None | PWD SR 2023-24 V-2 Page No-69 It No-10.4 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOOR | m | 732.24 | 732.24 | 7.2 | False | None | None | False | None | False | 5272.128 | 0 | 3606469 | 131066 | None | PWD SR 2023-24 V-2 Page No-27 It No-7.40.2 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOOR | Sqm | 2118.69 | 2118.69 | 6.87 | False | None | None | False | None | False | 14555.4003 | 0 | 3606470 | 131066 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 123.9 | 123.9 | 277.785 | False | None | None | False | None | False | 34417.5615 | 0 | 3606471 | 131066 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOOR | Sqm | 125.13 | 125.13 | 70.6 | False | None | None | False | None | False | 8834.178 | 0 | 3606472 | 131066 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOOR | Sqm | 65.66 | 65.66 | 277.785 | False | None | None | False | None | False | 18239.3631 | 0 | 3606473 | 131066 | None | PWD SR 2023-24 V-2 Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOOR | Sqm | 66.32 | 66.32 | 70.6 | False | None | None | False | None | False | 4682.192 | 0 | 3606474 | 131066 | None | PWD SR 2023-24 V-2 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 136.29 | 136.29 | 277.785 | False | None | None | False | None | False | 37859.31765 | 0 | 3606475 | 131066 | None | PWD SR 2023-24 V11 Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 137.65 | 137.65 | 70.6 | False | None | None | False | None | False | 9718.09 | 0 | 3606476 | 131066 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 215.58 | 215.58 | 120.42 | False | None | None | False | None | False | 25960.1436 | 0 | 3606477 | 131066 | None | PWD SR 2023-24 V11 Page No-46 It No-8.3 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 217.74 | 217.74 | 56.1 | False | None | None | False | None | False | 12215.214 | 0 | 3606478 | 131066 | None | Approved Rate | Providing and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only.
NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOOR | Sqm | 774.67 | 774.67 | 82.0 | False | None | None | False | None | False | 63522.94 | 0 | 3606479 | 131066 | None | PWD SR 2023-24 V11 Page No-54 It No-8.8 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 81.77 | 81.77 | 318.0 | False | None | None | False | None | False | 26002.86 | 0 | 3606480 | 131066 | None | PWD SR 2023-24 V11 Page No-43 It No-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Mesh | m | 42.12 | 42.12 | 318.0 | False | None | None | False | None | False | 13394.16 | 0 | 3606481 | 131066 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR) | Sqm | 5255.83 | 5255.83 | 2.52 | False | None | None | False | None | False | 13244.6916 | 0 | 3606482 | 131066 | None | PWD SR 2023-24 V-2 Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR) | Sqm | 5308.39 | 5308.39 | 2.52 | False | None | None | False | None | False | 13377.1428 | 0 | 3606483 | 131066 | None | PWDSR V-2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR) | m | 9.91 | 9.91 | 36.0 | False | None | None | False | None | False | 356.76 | 0 | 3606484 | 131066 | None | PWDV2SR 2021-22 Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR) | m | 10.01 | 10.01 | 32.94 | False | None | None | False | None | False | 329.7294 | 0 | 3606485 | 131066 | None | OLD SR 18-19 It No-4.55 | Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication charges | Sqm | 729.24 | 729.24 | 11.07 | False | None | None | False | None | False | 8072.6868 | 0 | 3606486 | 131066 | None | PWD SR 2023-24 V-2 Page No-131 It No-14.3.1 | NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 1.0 | False | None | None | False | None | False | 7405.5 | 0 | 3606487 | 131066 | None | LQ Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). | Each | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3606488 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.34.1 | Providing and fixing toilet paper holder :C.P. brass | Each | 753.31 | 753.31 | 1.0 | False | None | None | False | None | False | 753.31 | 0 | 3606489 | 131066 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.2.2 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore | Nos. | 377.89 | 377.89 | 1.0 | False | None | None | False | None | False | 377.89 | 0 | 3606490 | 131066 | None | PWD SR 2023-24 V-2 Page No-132 It No-14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 3173.07 | 3173.07 | 2.0 | False | None | None | False | None | False | 6346.14 | 0 | 3606491 | 131066 | None | PWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm | Nos. | 5986.84 | 5986.84 | 1.0 | False | None | None | False | None | False | 5986.84 | 0 | 3606492 | 131066 | None | PWD SR 2023-24 V-2 Page No-140 It No-14.62.a | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy | Nos. | 2388.79 | 2388.79 | 1.0 | False | None | None | False | None | False | 2388.79 | 0 | 3606493 | 131066 | None | PWD SR 2023-24 V-2 Page No-137 It No-14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3606494 | 131066 | None | PWD SR 2023-24 V-2 Page No-120 It No-13.22.2 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid | Nos. | 250.27 | 250.27 | 5.0 | False | None | None | False | None | False | 1251.35 | 0 | 3606495 | 131066 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos. | 1003.59 | 1003.59 | 3.0 | False | None | None | False | None | False | 3010.77 | 0 | 3606496 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 2.0 | False | None | None | False | None | False | 2522.6 | 0 | 3606497 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 58.23 | 58.23 | 4.0 | False | None | None | False | None | False | 232.92 | 0 | 3606498 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines | m | 113.98 | 113.98 | 6.0 | False | None | None | False | None | False | 683.88 | 0 | 3606499 | 131066 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes | m | 358.07 | 358.07 | 12.0 | False | None | None | False | None | False | 4296.84 | 0 | 3606500 | 131066 | None | PWD SR 2023-24 V-2 Page No-128 It No-13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes | m | 477.01 | 477.01 | 6.0 | False | None | None | False | None | False | 2862.06 | 0 | 3606501 | 131066 | None | LQ Rate | Air Vent Cowel -75 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3606502 | 131066 | None | LQ Rate | Air Vent Cowel -110 mm | Nos. | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3606503 | 131066 | None | PWD SR 2023-24 V-2 Page No-125 It No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter. | m | 360.54 | 360.54 | 4.0 | False | None | None | False | None | False | 1442.16 | 0 | 3606504 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes | m | 469.58 | 469.58 | 25.0 | False | None | None | False | None | False | 11739.5 | 0 | 3606505 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipes | m | 591.0 | 591.0 | 10.0 | False | None | None | False | None | False | 5910.0 | 0 | 3606506 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipes | m | 690.12 | 690.12 | 3.0 | False | None | None | False | None | False | 2070.36 | 0 | 3606507 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipes | m | 591.0 | 591.0 | 11.0 | False | None | None | False | None | False | 6501.0 | 0 | 3606508 | 131066 | None | PWD SR 2023-24 V-2 Page No-122 It No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipes | m | 902.25 | 902.25 | 32.0 | False | None | None | False | None | False | 28872.0 | 0 | 3606509 | 131066 | None | PWD SR 2023-24 V-2 Page No-136 It No-14.31 | Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos. | 1511.58 | 1511.58 | 1.0 | False | None | None | False | None | False | 1511.58 | 0 | 3606510 | 131066 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos. | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3606511 | 131066 | None | PWD SR 2023-24 V-2 Page No-135 It No-14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Nos. | 6891.31 | 6891.31 | 1.0 | False | None | None | False | None | False | 6891.31 | 0 | 3606512 | 131066 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos. | 768.18 | 768.18 | 1.0 | False | None | None | False | None | False | 768.18 | 0 | 3606513 | 131066 | None | PWD SR 2023-24 V-2 Page No-119 It No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 11.26 | 11.26 | 1000.0 | False | None | None | False | None | False | 11260.0 | 0 | 3606514 | 131066 | None | PWD SR 2023-24 V-2 Page No-121 It No-13.26 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos. | 123.9 | 123.9 | 5.0 | False | None | None | False | None | False | 619.5 | 0 | 3606515 | 131066 | None | PWD SR 2023-24 V-2 Page No-117 It No-13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Nos. | 415.46 | 415.46 | 1.0 | False | None | None | False | None | False | 415.46 | 0 | 3606516 | 131066 | None | PWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1 | Providing and fixing gun metal non- return valve of approved quality
(screwed end) : 40 mm nominal bore Horizontal | Nos. | 1201.33 | 1201.33 | 3.0 | False | None | None | False | None | False | 3603.99 | 0 | 3606517 | 131066 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valves | Nos. | 1877.08 | 1877.08 | 10.0 | False | None | None | False | None | False | 18770.8 | 0 | 3606518 | 131066 | None | PWD SR 2023-24 V-2 Page No-133 It No-11.15.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valves | Nos. | 2112.34 | 2112.34 | 1.0 | False | None | None | False | None | False | 2112.34 | 0 | 3606519 | 131066 | None | PWD SR 2023-24 V-2 Page No-86 It No-7.5.1 | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia. | Nos. | 1957.62 | 1957.62 | 1.0 | False | None | None | False | None | False | 1957.62 | 0 | 3606520 | 131066 | None | PWD SR 2023-24 V-2 Page No-123 It No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. | Nos. | 387.8 | 387.8 | 10.0 | False | None | None | False | None | False | 3878.0 | 0 | 3606521 | 131066 | None | PWD SR Old Sr 2018- 19 It No-11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 | Nos. | 18749.78 | 18749.78 | 2.0 | False | None | None | False | None | False | 37499.56 | 0 | 3606522 | 131066 | None | PWD SR 2023-24 V-2 Page No-126 It No-13.53 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 | Nos. | 6990.43 | 6990.43 | 2.0 | False | None | None | False | None | False | 13980.86 | 0 | 3606523 | 131066 | None | PWD SR 2023-24 V-2 Page No-124 It No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. | Nos. | 3197.85 | 3197.85 | 4.0 | False | None | None | False | None | False | 12791.4 | 0 | 3606524 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.1 | NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box | Point | 317.42 | 317.42 | 3.0 | False | None | None | False | None | False | 952.26 | 0 | 3606525 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 447.22 | 447.22 | 13.0 | False | None | None | False | None | False | 5813.86 | 0 | 3606526 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 654.9 | 654.9 | 2.0 | False | None | None | False | None | False | 1309.8 | 0 | 3606527 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 1.0 | False | None | None | False | None | False | 798.86 | 0 | 3606528 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 Way | Each | 121.54 | 121.54 | 1.0 | False | None | None | False | None | False | 121.54 | 0 | 3606529 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 Way | Each | 146.32 | 146.32 | 1.0 | False | None | None | False | None | False | 146.32 | 0 | 3606530 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5Way | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3606531 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 Way | Each | 204.14 | 204.14 | 1.0 | False | None | None | False | None | False | 204.14 | 0 | 3606532 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 Way | Each | 258.42 | 258.42 | 1.0 | False | None | None | False | None | False | 258.42 | 0 | 3606533 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 Way | Each | 162.84 | 162.84 | 4.0 | False | None | None | False | None | False | 651.36 | 0 | 3606534 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 Way | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3606535 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5Way | Each | 208.86 | 208.86 | 4.0 | False | None | None | False | None | False | 835.44 | 0 | 3606536 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 259.6 | 259.6 | 5.0 | False | None | None | False | None | False | 1298.0 | 0 | 3606537 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 307.98 | 307.98 | 2.0 | False | None | None | False | None | False | 615.96 | 0 | 3606538 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 Way | Each | 376.42 | 376.42 | 2.0 | False | None | None | False | None | False | 752.84 | 0 | 3606539 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 3606540 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 Module | Each | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 3606541 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 3606542 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 Module | Each | 276.12 | 276.12 | 6.0 | False | None | None | False | None | False | 1656.72 | 0 | 3606543 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 Module | Each | 335.12 | 335.12 | 3.0 | False | None | None | False | None | False | 1005.36 | 0 | 3606544 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12Module | Each | 405.92 | 405.92 | 2.0 | False | None | None | False | None | False | 811.84 | 0 | 3606545 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switch | Each | 120.36 | 120.36 | 36.0 | False | None | None | False | None | False | 4332.96 | 0 | 3606546 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switch | Each | 195.88 | 195.88 | 6.0 | False | None | None | False | None | False | 1175.28 | 0 | 3606547 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way sockets | Each | 201.78 | 201.78 | 14.0 | False | None | None | False | None | False | 2824.92 | 0 | 3606548 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator's | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 | 3606549 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 278.48 | 278.48 | 5.0 | False | None | None | False | None | False | 1392.4 | 0 | 3606550 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 212.4 | 212.4 | 5.0 | False | None | None | False | None | False | 1062.0 | 0 | 3606551 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 3606552 | 131066 | None | PWD SR 2023-24 Volume 6 It No-3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 208.86 | 208.86 | 1.0 | False | None | None | False | None | False | 208.86 | 0 | 3606553 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Ding Donng bell | Each | 290.28 | 290.28 | 1.0 | False | None | None | False | None | False | 290.28 | 0 | 3606554 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.12 | Extra length of GI pipe of class B 19mm dia for down rod. | Each | 232.46 | 232.46 | 3.0 | False | None | None | False | None | False | 697.38 | 0 | 3606555 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.13 | Supply and fixing one metal Fan box with round hook | Each | 138.06 | 138.06 | 3.0 | False | None | None | False | None | False | 414.18 | 0 | 3606556 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.1 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
20 mm dia 2mm thick | m | 77.88 | 77.88 | 145.0 | False | None | None | False | None | False | 11292.6 | 0 | 3606557 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.2 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thick | m | 92.04 | 92.04 | 185.0 | False | None | None | False | None | False | 17027.4 | 0 | 3606558 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.2.3 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3606559 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.3.1 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thick | m | 80.24 | 80.24 | 30.0 | False | None | None | False | None | False | 2407.2 | 0 | 3606560 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.3.2 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | m | 93.22 | 93.22 | 35.0 | False | None | None | False | None | False | 3262.7 | 0 | 3606561 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.3.3 | Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | m | 116.82 | 116.82 | 5.0 | False | None | None | False | None | False | 584.1 | 0 | 3606562 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box | Each | 57.82 | 57.82 | 15.0 | False | None | None | False | None | False | 867.3 | 0 | 3606563 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box | Each | 66.08 | 66.08 | 20.0 | False | None | None | False | None | False | 1321.6 | 0 | 3606564 | 131066 | None | PWD SR 2023-24 Volume 6 It No-1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction box | Each | 71.98 | 71.98 | 2.0 | False | None | None | False | None | False | 143.96 | 0 | 3606565 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.2 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 265.0 | False | None | None | False | None | False | 8130.2 | 0 | 3606566 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.3 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 49.56 | 49.56 | 320.0 | False | None | None | False | None | False | 15859.2 | 0 | 3606567 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.4 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mm | m | 74.34 | 74.34 | 220.0 | False | None | None | False | None | False | 16354.8 | 0 | 3606568 | 131066 | None | PWD SR 2023-24 Volume 6 It No-2.3.5 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mm | m | 108.56 | 108.56 | 60.0 | False | None | None | False | None | False | 6513.6 | 0 | 3606569 | 131066 | None | MR 1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.54 | 3.54 | 40.0 | False | None | None | False | None | False | 141.6 | 0 | 3606570 | 131066 | None | MR 2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.72 | 4.72 | 60.0 | False | None | None | False | None | False | 283.2 | 0 | 3606571 | 131066 | None | MR 3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 8.26 | 8.26 | 16.0 | False | None | None | False | None | False | 132.16 | 0 | 3606572 | 131066 | None | MR 4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 8.26 | 8.26 | 4.0 | False | None | None | False | None | False | 33.04 | 0 | 3606573 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.19.6 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & N | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 | 3606574 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.19.9 | MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 3606575 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32 A SP | Each | 489.7 | 489.7 | 12.0 | False | None | None | False | None | False | 5876.4 | 0 | 3606576 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 40 A DP | Each | 1250.8 | 1250.8 | 2.0 | False | None | None | False | None | False | 2501.6 | 0 | 3606577 | 131066 | None | PWD SR 2023-24 Volume 6 It No-5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 50-63 A TPN | Each | 3643.84 | 3643.84 | 1.0 | False | None | None | False | None | False | 3643.84 | 0 | 3606578 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.3.2 | ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W | Each | 814.2 | 814.2 | 4.0 | False | None | None | False | None | False | 3256.8 | 0 | 3606579 | 131066 | None | PWD SR 2023-24 Volume 6 It No-11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 8.0 | False | None | None | False | None | False | 12498.56 | 0 | 3606580 | 131066 | None | MR 5 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 531.0 | 531.0 | 9.0 | False | None | None | False | None | False | 4779.0 | 0 | 3606581 | 131066 | None | MR 6 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1947.0 | 1947.0 | 3.0 | False | None | None | False | None | False | 5841.0 | 0 | 3606582 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3606583 | 131066 | None | PWD SR 2023-24 Volume 6 It No-6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm) | Each | 3158.86 | 3158.86 | 3.0 | False | None | None | False | None | False | 9476.58 | 0 | 3606584 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 143.96 | 143.96 | 12.0 | False | None | None | False | None | False | 1727.52 | 0 | 3606585 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.1 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 3.0 | False | None | None | False | None | False | 605.34 | 0 | 3606586 | 131066 | None | PWD SR 2023-24 Volume 6 It No-13.13 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3606587 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3606588 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI strip | m | 96.76 | 96.76 | 30.0 | False | None | None | False | None | False | 2902.8 | 0 | 3606589 | 131066 | None | PWD SR 2023-24 Volume 6 It No-12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI Plate | Each | 1032.5 | 1032.5 | 2.0 | False | None | None | False | None | False | 2065.0 | 0 | 3606590 | 131066 | None | MR 7 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire | m | 28.32 | 28.32 | 80.0 | False | None | None | False | None | False | 2265.6 | 0 | 3606591 | 131066 | None | data rate | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Job | 260945.0 | 260945.0 | 1.0 | False | None | None | False | None | False | 260945.0 | 0 |
|
|
---|