createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721810360335
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd2805000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 16:00:00
tenderQueryClose14-08-2024 16:00:00
technicalBidOpen27-08-2024 16:01:00
publishedDate24-07-2024 14:20:03
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate19-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9686183379
tenderSupplierListNone
tenderSchedule
createdTs1721810360366
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT544
titleConstruction of Primary Health Centre at Nilogal, Taluvagera, Lingadalhali, Hirebannigol in Kushtagi Taluk and Singanal, Jeeral, Basapattana, Gouripur in Gangavathi Taluk in Koppal Distric
descriptionConstruction of Primary Health Centre at Nilogal, Taluvagera, Lingadalhali, Hirebannigol in Kushtagi Taluk and Singanal, Jeeral, Basapattana, Gouripur in Gangavathi Taluk in Koppal District
categoryWORKS
categoryTextWorks
ecv280429340.48
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount320000000.0
groupOverheadTotalNone
fileNumberAEE/BALLARI/KKRDB/KOPPAL
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218103600000NoneNoneBuildingsConstruction of primary health centre at nilogal, in kushtagi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600912131059NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3600913131059NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3600914131059NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3600915131059NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3600916131059NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3600917131059NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3600918131059NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3600919131059NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3600920131059NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3600921131059NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3600922131059NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3600923131059NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3600924131059NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3600925131059NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3600926131059NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3600927131059NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3600928131059NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3600929131059NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3600930131059NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3600931131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3600932131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3600933131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3600934131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3600935131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3600936131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3600937131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3600938131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3600939131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3600940131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3600941131059NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3600942131059NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3600943131059NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3600944131059NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3600945131059NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3600946131059NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3600947131059NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3600948131059NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3600949131059NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3600950131059NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3600951131059NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3600952131059NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3600953131059NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3600954131059NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3600955131059NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3600956131059NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3600957131059NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3600958131059NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3600959131059NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3600960131059NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3600961131059NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3600962131059NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3600963131059NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3600964131059NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3600965131059NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3600966131059NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3600967131059NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3600968131059NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3600969131059NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3600970131059NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3600971131059NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3600972131059NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3600973131059NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3600974131059NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3600975131059NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3600976131059NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3600977131059NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3600978131059NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3600979131059NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3600980131059NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3600981131059NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3600982131059NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3600983131059NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3600984131059NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3600985131059NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3600986131059NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3600987131059NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3600988131059NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3600989131059NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3600990131059NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3600991131059NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3600992131059NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3600993131059NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3600994131059NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3600995131059NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3600996131059NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3600997131059NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3600998131059NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3600999131059NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3601000131059NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3601001131059NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3601002131059NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3601003131059NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3601004131059NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3601005131059NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3601006131059NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3601007131059NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3601008131059NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3601009131059NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3601010131059NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3601011131059NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3601012131059NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3601013131059NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3601014131059NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3601015131059NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3601016131059NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3601017131059NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3601018131059NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3601019131059NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3601020131059NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3601021131059NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3601022131059NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3601023131059NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3601024131059NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3601025131059NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3601026131059NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3601027131059NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3601028131059NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3601029131059NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3601030131059NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3601031131059NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3601032131059NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3601033131059NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3601034131059NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3601035131059NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3601036131059NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3601037131059NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3601038131059NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3601039131059NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3601040131059NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3601041131059NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3601042131059NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3601043131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3601044131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3601045131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3601046131059NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3601047131059NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3601048131059NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3601049131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3601050131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3601051131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3601052131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3601053131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3601054131059NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3601055131059NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3601056131059NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3601057131059NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3601058131059NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3601059131059NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3601060131059NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3601061131059NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3601062131059NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3601063131059NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3601064131059NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3601065131059NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3601066131059NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3601067131059NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3601068131059NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3601069131059NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3601070131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3601071131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3601072131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3601073131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3601074131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3601075131059NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3601076131059NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3601077131059NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3601078131059NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3601079131059NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3601080131059NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3601081131059NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3601082131059NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3601083131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3601084131059NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3601085131059NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3601086131059NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3601087131059NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3601088131059NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3601089131059NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3601090131059NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3601091131059NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3601092131059NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3601093131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3601094131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3601095131059NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3601096131059NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3601097131059NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3601098131059NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3601099131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3601100131059NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3601101131059NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3601102131059NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3601103131059NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3601104131059NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3601105131059NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3601106131059NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3601107131059NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3601108131059NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3601109131059NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3601110131059NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3601111131059NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3601112131059NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3601113131059NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3601114131059NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3601115131059NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3601116131059NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3601117131059NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3601118131059NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3601119131059NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3601120131059NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3601121131059NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3601122131059NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3601123131059NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3601124131059NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3601125131059NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3601126131059NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3601127131059NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3601128131059NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3601129131059NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3601130131059NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3601131131059NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3601132131059NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3601133131059NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3601134131059NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3601135131059NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3601136131059NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3601137131059NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3601138131059NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3601139131059NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3601140131059NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3601141131059NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3601142131059NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3601143131059NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3601144131059NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3601145131059NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3601146131059NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3601147131059NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3601148131059NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3601149131059NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3601150131059NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3601151131059NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3601152131059NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3601153131059NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3601154131059NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3601155131059NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3601156131059NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3601157131059NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3601158131059NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3601159131059NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3601160131059NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3601161131059NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3601162131059NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3601163131059NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3601164131059NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3601165131059NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3601166131059NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3601167131059NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3601168131059NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3601169131059NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3601170131059NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3601171131059NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3601172131059NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3601173131059NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3601174131059NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3601175131059NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3601176131059NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3601177131059NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3601178131059NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3601179131059NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3601180131059NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3601181131059NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3601182131059NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3601183131059NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3601184131059NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3601185131059NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3601186131059NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3601187131059NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3601188131059NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3601189131059NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3601190131059NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3601191131059NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3601192131059NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3601193131059NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3601194131059NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3601195131059NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3601196131059NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3601197131059NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3601198131059NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3601199131059NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3601200131059NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3601201131059NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3601202131059NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3601203131059NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3601204131059NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3601205131059NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3601206131059NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3601207131059NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3601208131059NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3601209131059NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3601210131059NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3601211131059NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3601212131059NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3601213131059NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3601214131059NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3601215131059NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3601216131059NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3601217131059NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3601218131059NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3601219131059NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3601220131059NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3601221131059NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3601222131059NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3601223131059NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3601224131059NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3601225131059NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3601226131059NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3601227131059NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3601228131059NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3601229131059NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3601230131059NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3601231131059NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3601232131059NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3601233131059NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3601234131059NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3601235131059NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3601236131059NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3601237131059NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3601238131059NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3601239131059NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3601240131059NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3601241131059NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3601242131059NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3601243131059NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3601244131059NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3601245131059NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3601246131059NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3601247131059NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3601248131059NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3601249131059NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3601250131059NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3601251131059NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3601252131059NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3601253131059NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3601254131059NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3601255131059NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3601256131059NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3601257131059NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3601258131059NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3601259131059NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3601260131059NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3601261131059NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3601262131059NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3601263131059NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3601264131059NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3601265131059NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3601266131059NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3601267131059NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3601268131059NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3601269131059NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3601270131059NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3601271131059NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3601272131059NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3601273131059NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3601274131059NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3601275131059NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3601276131059NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3601277131059NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3601278131059NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3601279131059NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3601280131059NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3601281131059NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3601282131059NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3601283131059NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3601284131059NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3601285131059NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3601286131059NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3601287131059NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3601288131059NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3601289131059NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3601290131059NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3601291131059NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3601292131059NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3601293131059NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3601294131059NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3601295131059NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3601296131059NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3601297131059NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3601298131059NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3601299131059NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3601300131059NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3601301131059NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3601302131059NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3601303131059NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3601304131059NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3601305131059NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3601306131059NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3601307131059NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3601308131059NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3601309131059NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3601310131059NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3601311131059NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3601312131059NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3601313131059NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3601314131059NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3601315131059NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3601316131059NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3601317131059NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3601318131059NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3601319131059NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3601320131059NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3601321131059NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3601322131059NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3601323131059NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3601324131059NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3601325131059NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3601326131059NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3601327131059NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3601328131059NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3601329131059NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3601330131059NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3601331131059NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3601332131059NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3601333131059NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3601334131059NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3601335131059NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3601336131059NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3601337131059NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3601338131059NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3601339131059NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3601340131059NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3601341131059NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3601342131059NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3601343131059NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3601344131059NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3601345131059NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3601346131059NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3601347131059NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3601348131059NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3601349131059NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3601350131059NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3601351131059NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3601352131059NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3601353131059NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3601354131059NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3601355131059NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3601356131059NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3601357131059NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3601358131059NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3601359131059NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3601360131059NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3601361131059NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3601362131059NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3601363131059NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3601364131059NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3601365131059NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3601366131059NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3601367131059NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3601368131059NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3601369131059NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3601370131059NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3601371131059NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3601372131059NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3601373131059NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3601374131059NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3601375131059NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3601376131059NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3601377131059NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3601378131059NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3601379131059NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3601380131059NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3601381131059NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3601382131059NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3601383131059NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3601384131059NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3601385131059NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3601386131059NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3601387131059NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3601388131059NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3601389131059NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3601390131059NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3601391131059NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3601392131059NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3601393131059NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3601394131059NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3601395131059NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3601396131059NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3601397131059NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3601398131059NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3601399131059NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3601400131059NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3601401131059NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3601402131059NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3601403131059NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3601404131059NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3601405131059NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3601406131059NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3601407131059NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3601408131059NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3601409131059NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3601410131059NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3601411131059NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3601412131059NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3601413131059NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3601414131059NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3601415131059NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3601416131059NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3601417131059NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3601418131059NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3601419131059NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3601420131059NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3601421131059NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3601422131059NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3601423131059NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3601424131059NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3601425131059NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3601426131059NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3601427131059NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3601428131059NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3601429131059NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3601430131059NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3601431131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3601432131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3601433131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3601434131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3601435131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3601436131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3601437131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3601438131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3601439131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3601440131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3601441131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3601442131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3601443131059NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3601444131059NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3601445131059NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3601446131059NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3601447131059NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3601448131059NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3601449131059NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3601450131059NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3601451131059NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3601452131059NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3601453131059NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3601454131059NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3601455131059NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3601456131059NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3601457131059NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3601458131059NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3601459131059NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3601460131059NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3601461131059NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3601462131059NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3601463131059NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3601464131059NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3601465131059NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3601466131059NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3601467131059NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3601468131059NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3601469131059NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3601470131059NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3601471131059NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3601472131059NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3601473131059NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3601474131059NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3601475131059NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3601476131059NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3601477131059NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3601478131059NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3601479131059NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3601480131059NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3601481131059NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3601482131059NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3601483131059NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3601484131059NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3601485131059NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3601486131059NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3601487131059NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3601488131059NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3601489131059NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3601490131059NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3601491131059NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3601492131059NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3601493131059NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3601494131059NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3601495131059NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3601496131059NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3601497131059NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3601498131059NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3601499131059NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3601500131059NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3601501131059NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3601502131059NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3601503131059NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3601504131059NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3601505131059NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3601506131059NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3601507131059NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3601508131059NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3601509131059NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3601510131059NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3601511131059NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3601512131059NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3601513131059NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3601514131059NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3601515131059NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3601516131059NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3601517131059NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3601518131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3601519131059NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3601520131059NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3601521131059NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3601522131059NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3601523131059NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3601524131059NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3601525131059NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3601526131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3601527131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3601528131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3601529131059NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3601530131059NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3601531131059NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3601532131059NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3601533131059NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3601534131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3601535131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3601536131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3601537131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3601538131059NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3601539131059NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3601540131059NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3601541131059NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3601542131059NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3601543131059NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3601544131059NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3601545131059NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3601546131059NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3601547131059NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3601548131059NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3601549131059NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3601550131059NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3601551131059NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3601552131059NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3601553131059NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3601554131059NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3601555131059NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3601556131059NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3601557131059NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3601558131059NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3601559131059NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3601560131059NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3601561131059NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3601562131059NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3601563131059NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3601564131059NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3601565131059NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3601566131059NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3601567131059NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3601568131059NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3601569131059NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3601570131059NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3601571131059NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3601572131059NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3601573131059NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3601574131059NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3601575131059NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3601576131059NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3601577131059NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3601578131059NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3601579131059NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3601580131059NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3601581131059NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3601582131059NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3601583131059NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3601584131059NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3601585131059NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3601586131059NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3601587131059NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3601588131059NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3601589131059NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3601590131059NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3601591131059NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3601592131059NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3601593131059NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3601594131059NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3601595131059NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3601596131059NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3601597131059NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3601598131059NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3601599131059NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3601600131059NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3601601131059NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3601602131059NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3601603131059NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3601604131059NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3601605131059NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3601606131059NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3601607131059NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3601608131059NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3601609131059NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3601610131059NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3601611131059NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3601612131059NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3601613131059NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3601614131059NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3601615131059NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3601616131059NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3601617131059NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3601618131059NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3601619131059NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3601620131059NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3601621131059Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218103610000NoneNoneBuildingsConstruction of primary health centre at taluvagera, in kushtagi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3601622131060NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3601623131060NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3601624131060NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3601625131060NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3601626131060NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3601627131060NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3601628131060NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3601629131060NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3601630131060NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3601631131060NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3601632131060NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3601633131060NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3601634131060NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3601635131060NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3601636131060NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3601637131060NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3601638131060NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3601639131060NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3601640131060NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3601641131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3601642131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3601643131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3601644131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3601645131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3601646131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3601647131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3601648131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3601649131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3601650131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3601651131060NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3601652131060NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3601653131060NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3601654131060NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3601655131060NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3601656131060NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3601657131060NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3601658131060NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3601659131060NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3601660131060NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3601661131060NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3601662131060NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3601663131060NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3601664131060NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3601665131060NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3601666131060NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3601667131060NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3601668131060NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3601669131060NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3601670131060NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3601671131060NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3601672131060NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3601673131060NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3601674131060NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3601675131060NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3601676131060NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3601677131060NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3601678131060NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3601679131060NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3601680131060NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3601681131060NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3601682131060NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3601683131060NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3601684131060NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3601685131060NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3601686131060NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3601687131060NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3601688131060NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3601689131060NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3601690131060NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3601691131060NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3601692131060NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3601693131060NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3601694131060NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3601695131060NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3601696131060NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3601697131060NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3601698131060NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3601699131060NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3601700131060NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3601701131060NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3601702131060NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3601703131060NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3601704131060NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3601705131060NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3601706131060NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3601707131060NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3601708131060NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3601709131060NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3601710131060NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3601711131060NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3601712131060NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3601713131060NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3601714131060NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3601715131060NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3601716131060NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3601717131060NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3601718131060NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3601719131060NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3601720131060NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3601721131060NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3601722131060NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3601723131060NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3601724131060NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3601725131060NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3601726131060NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3601727131060NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3601728131060NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3601729131060NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3601730131060NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3601731131060NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3601732131060NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3601733131060NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3601734131060NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3601735131060NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3601736131060NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3601737131060NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3601738131060NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3601739131060NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3601740131060NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3601741131060NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3601742131060NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3601743131060NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3601744131060NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3601745131060NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3601746131060NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3601747131060NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3601748131060NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3601749131060NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3601750131060NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3601751131060NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3601752131060NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3601753131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3601754131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3601755131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3601756131060NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3601757131060NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3601758131060NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3601759131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3601760131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3601761131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3601762131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3601763131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3601764131060NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3601765131060NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3601766131060NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3601767131060NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3601768131060NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3601769131060NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3601770131060NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3601771131060NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3601772131060NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3601773131060NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3601774131060NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3601775131060NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3601776131060NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3601777131060NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3601778131060NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3601779131060NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3601780131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3601781131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3601782131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3601783131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3601784131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3601785131060NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3601786131060NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3601787131060NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3601788131060NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3601789131060NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3601790131060NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3601791131060NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3601792131060NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3601793131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3601794131060NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3601795131060NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3601796131060NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3601797131060NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3601798131060NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3601799131060NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3601800131060NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3601801131060NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3601802131060NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3601803131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3601804131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3601805131060NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3601806131060NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3601807131060NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3601808131060NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3601809131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3601810131060NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3601811131060NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3601812131060NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3601813131060NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3601814131060NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3601815131060NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3601816131060NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3601817131060NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3601818131060NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3601819131060NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3601820131060NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3601821131060NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3601822131060NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3601823131060NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3601824131060NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3601825131060NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3601826131060NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3601827131060NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3601828131060NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3601829131060NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3601830131060NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3601831131060NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3601832131060NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3601833131060NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3601834131060NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3601835131060NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3601836131060NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3601837131060NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3601838131060NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3601839131060NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3601840131060NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3601841131060NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3601842131060NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3601843131060NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3601844131060NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3601845131060NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3601846131060NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3601847131060NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3601848131060NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3601849131060NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3601850131060NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3601851131060NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3601852131060NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3601853131060NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3601854131060NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3601855131060NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3601856131060NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3601857131060NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3601858131060NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3601859131060NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3601860131060NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3601861131060NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3601862131060NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3601863131060NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3601864131060NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3601865131060NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3601866131060NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3601867131060NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3601868131060NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3601869131060NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3601870131060NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3601871131060NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3601872131060NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3601873131060NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3601874131060NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3601875131060NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3601876131060NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3601877131060NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3601878131060NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3601879131060NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3601880131060NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3601881131060NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3601882131060NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3601883131060NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3601884131060NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3601885131060NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3601886131060NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3601887131060NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3601888131060NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3601889131060NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3601890131060NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3601891131060NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3601892131060NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3601893131060NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3601894131060NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3601895131060NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3601896131060NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3601897131060NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3601898131060NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3601899131060NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3601900131060NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3601901131060NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3601902131060NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3601903131060NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3601904131060NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3601905131060NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3601906131060NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3601907131060NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3601908131060NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3601909131060NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3601910131060NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3601911131060NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3601912131060NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3601913131060NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3601914131060NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3601915131060NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3601916131060NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3601917131060NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3601918131060NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3601919131060NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3601920131060NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3601921131060NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3601922131060NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3601923131060NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3601924131060NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3601925131060NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3601926131060NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3601927131060NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3601928131060NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3601929131060NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3601930131060NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3601931131060NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3601932131060NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3601933131060NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3601934131060NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3601935131060NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3601936131060NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3601937131060NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3601938131060NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3601939131060NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3601940131060NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3601941131060NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3601942131060NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3601943131060NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3601944131060NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3601945131060NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3601946131060NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3601947131060NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3601948131060NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3601949131060NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3601950131060NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3601951131060NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3601952131060NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3601953131060NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3601954131060NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3601955131060NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3601956131060NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3601957131060NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3601958131060NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3601959131060NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3601960131060NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3601961131060NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3601962131060NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3601963131060NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3601964131060NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3601965131060NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3601966131060NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3601967131060NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3601968131060NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3601969131060NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3601970131060NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3601971131060NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3601972131060NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3601973131060NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3601974131060NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3601975131060NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3601976131060NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3601977131060NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3601978131060NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3601979131060NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3601980131060NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3601981131060NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3601982131060NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3601983131060NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3601984131060NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3601985131060NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3601986131060NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3601987131060NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3601988131060NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3601989131060NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3601990131060NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3601991131060NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3601992131060NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3601993131060NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3601994131060NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3601995131060NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3601996131060NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3601997131060NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3601998131060NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3601999131060NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3602000131060NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3602001131060NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3602002131060NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3602003131060NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3602004131060NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3602005131060NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3602006131060NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3602007131060NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3602008131060NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3602009131060NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3602010131060NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3602011131060NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3602012131060NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3602013131060NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3602014131060NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3602015131060NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3602016131060NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3602017131060NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3602018131060NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3602019131060NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3602020131060NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3602021131060NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3602022131060NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3602023131060NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3602024131060NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3602025131060NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3602026131060NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3602027131060NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3602028131060NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3602029131060NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3602030131060NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3602031131060NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3602032131060NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3602033131060NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3602034131060NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3602035131060NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3602036131060NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3602037131060NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3602038131060NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3602039131060NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3602040131060NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3602041131060NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3602042131060NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3602043131060NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3602044131060NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3602045131060NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3602046131060NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3602047131060NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3602048131060NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3602049131060NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3602050131060NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3602051131060NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3602052131060NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3602053131060NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3602054131060NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3602055131060NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3602056131060NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3602057131060NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3602058131060NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3602059131060NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3602060131060NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3602061131060NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3602062131060NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3602063131060NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3602064131060NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3602065131060NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3602066131060NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3602067131060NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3602068131060NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3602069131060NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3602070131060NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3602071131060NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3602072131060NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3602073131060NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3602074131060NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3602075131060NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3602076131060NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3602077131060NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3602078131060NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3602079131060NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3602080131060NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3602081131060NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3602082131060NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3602083131060NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3602084131060NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3602085131060NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3602086131060NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3602087131060NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3602088131060NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3602089131060NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3602090131060NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3602091131060NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3602092131060NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3602093131060NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3602094131060NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3602095131060NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3602096131060NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3602097131060NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3602098131060NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3602099131060NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3602100131060NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3602101131060NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3602102131060NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3602103131060NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3602104131060NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3602105131060NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3602106131060NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3602107131060NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3602108131060NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3602109131060NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3602110131060NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3602111131060NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3602112131060NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3602113131060NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3602114131060NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3602115131060NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3602116131060NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3602117131060NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3602118131060NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3602119131060NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3602120131060NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3602121131060NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3602122131060NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3602123131060NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3602124131060NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3602125131060NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3602126131060NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3602127131060NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3602128131060NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3602129131060NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3602130131060NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3602131131060NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3602132131060NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3602133131060NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3602134131060NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3602135131060NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3602136131060NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3602137131060NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3602138131060NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3602139131060NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3602140131060NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3602141131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3602142131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3602143131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3602144131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3602145131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3602146131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3602147131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3602148131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3602149131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3602150131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3602151131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3602152131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3602153131060NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3602154131060NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3602155131060NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3602156131060NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3602157131060NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3602158131060NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3602159131060NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3602160131060NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3602161131060NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3602162131060NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3602163131060NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3602164131060NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3602165131060NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3602166131060NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3602167131060NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3602168131060NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3602169131060NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3602170131060NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3602171131060NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3602172131060NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3602173131060NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3602174131060NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3602175131060NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3602176131060NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3602177131060NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3602178131060NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3602179131060NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3602180131060NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3602181131060NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3602182131060NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3602183131060NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3602184131060NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3602185131060NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3602186131060NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3602187131060NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3602188131060NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3602189131060NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3602190131060NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3602191131060NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3602192131060NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3602193131060NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3602194131060NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3602195131060NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3602196131060NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3602197131060NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3602198131060NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3602199131060NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3602200131060NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3602201131060NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3602202131060NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3602203131060NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3602204131060NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3602205131060NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3602206131060NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3602207131060NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3602208131060NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3602209131060NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3602210131060NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3602211131060NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3602212131060NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3602213131060NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3602214131060NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3602215131060NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3602216131060NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3602217131060NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3602218131060NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3602219131060NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3602220131060NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3602221131060NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3602222131060NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3602223131060NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3602224131060NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3602225131060NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3602226131060NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3602227131060NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3602228131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3602229131060NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3602230131060NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3602231131060NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3602232131060NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3602233131060NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3602234131060NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3602235131060NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3602236131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3602237131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3602238131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3602239131060NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3602240131060NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3602241131060NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3602242131060NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3602243131060NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3602244131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3602245131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3602246131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3602247131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3602248131060NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3602249131060NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3602250131060NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3602251131060NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3602252131060NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3602253131060NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3602254131060NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3602255131060NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3602256131060NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3602257131060NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3602258131060NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3602259131060NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3602260131060NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3602261131060NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3602262131060NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3602263131060NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3602264131060NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3602265131060NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3602266131060NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3602267131060NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3602268131060NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3602269131060NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3602270131060NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3602271131060NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3602272131060NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3602273131060NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3602274131060NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3602275131060NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3602276131060NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3602277131060NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3602278131060NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3602279131060NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3602280131060NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3602281131060NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3602282131060NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3602283131060NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3602284131060NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3602285131060NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3602286131060NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3602287131060NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3602288131060NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3602289131060NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3602290131060NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3602291131060NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3602292131060NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3602293131060NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3602294131060NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3602295131060NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3602296131060NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3602297131060NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3602298131060NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3602299131060NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3602300131060NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3602301131060NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3602302131060NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3602303131060NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3602304131060NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3602305131060NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3602306131060NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3602307131060NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3602308131060NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3602309131060NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3602310131060NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3602311131060NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3602312131060NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3602313131060NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3602314131060NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3602315131060NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3602316131060NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3602317131060NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3602318131060NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3602319131060NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3602320131060NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3602321131060NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3602322131060NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3602323131060NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3602324131060NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3602325131060NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3602326131060NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3602327131060NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3602328131060NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3602329131060NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3602330131060NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3602331131060Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218103610000NoneNoneBuildingsConstruction of primary health centre at lingadahalli, in kushtagi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3602332131061NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3602333131061NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3602334131061NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3602335131061NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3602336131061NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3602337131061NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3602338131061NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3602339131061NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3602340131061NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3602341131061NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3602342131061NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3602343131061NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3602344131061NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3602345131061NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3602346131061NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3602347131061NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3602348131061NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3602349131061NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3602350131061NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3602351131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3602352131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3602353131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3602354131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3602355131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3602356131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3602357131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3602358131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3602359131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3602360131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3602361131061NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3602362131061NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3602363131061NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3602364131061NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3602365131061NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3602366131061NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3602367131061NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3602368131061NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3602369131061NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3602370131061NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3602371131061NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3602372131061NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3602373131061NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3602374131061NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3602375131061NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3602376131061NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3602377131061NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3602378131061NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3602379131061NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3602380131061NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3602381131061NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3602382131061NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3602383131061NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3602384131061NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3602385131061NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3602386131061NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3602387131061NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3602388131061NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3602389131061NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3602390131061NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3602391131061NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3602392131061NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3602393131061NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3602394131061NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3602395131061NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3602396131061NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3602397131061NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3602398131061NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3602399131061NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3602400131061NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3602401131061NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3602402131061NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3602403131061NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3602404131061NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3602405131061NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3602406131061NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3602407131061NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3602408131061NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3602409131061NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3602410131061NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3602411131061NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3602412131061NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3602413131061NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3602414131061NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3602415131061NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3602416131061NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3602417131061NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3602418131061NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3602419131061NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3602420131061NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3602421131061NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3602422131061NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3602423131061NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3602424131061NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3602425131061NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3602426131061NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3602427131061NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3602428131061NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3602429131061NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3602430131061NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3602431131061NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3602432131061NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3602433131061NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3602434131061NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3602435131061NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3602436131061NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3602437131061NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3602438131061NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3602439131061NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3602440131061NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3602441131061NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3602442131061NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3602443131061NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3602444131061NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3602445131061NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3602446131061NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3602447131061NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3602448131061NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3602449131061NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3602450131061NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3602451131061NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3602452131061NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3602453131061NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3602454131061NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3602455131061NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3602456131061NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3602457131061NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3602458131061NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3602459131061NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3602460131061NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3602461131061NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3602462131061NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3602463131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3602464131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3602465131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3602466131061NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3602467131061NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3602468131061NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3602469131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3602470131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3602471131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3602472131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3602473131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3602474131061NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3602475131061NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3602476131061NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3602477131061NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3602478131061NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3602479131061NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3602480131061NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3602481131061NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3602482131061NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3602483131061NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3602484131061NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3602485131061NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3602486131061NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3602487131061NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3602488131061NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3602489131061NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3602490131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3602491131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3602492131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3602493131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3602494131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3602495131061NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3602496131061NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3602497131061NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3602498131061NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3602499131061NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3602500131061NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3602501131061NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3602502131061NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3602503131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3602504131061NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3602505131061NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3602506131061NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3602507131061NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3602508131061NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3602509131061NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3602510131061NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3602511131061NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3602512131061NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3602513131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3602514131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3602515131061NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3602516131061NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3602517131061NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3602518131061NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3602519131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3602520131061NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3602521131061NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3602522131061NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3602523131061NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3602524131061NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3602525131061NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3602526131061NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3602527131061NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3602528131061NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3602529131061NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3602530131061NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3602531131061NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3602532131061NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3602533131061NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3602534131061NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3602535131061NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3602536131061NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3602537131061NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3602538131061NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3602539131061NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3602540131061NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3602541131061NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3602542131061NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3602543131061NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3602544131061NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3602545131061NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3602546131061NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3602547131061NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3602548131061NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3602549131061NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3602550131061NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3602551131061NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3602552131061NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3602553131061NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3602554131061NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3602555131061NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3602556131061NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3602557131061NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3602558131061NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3602559131061NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3602560131061NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3602561131061NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3602562131061NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3602563131061NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3602564131061NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3602565131061NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3602566131061NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3602567131061NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3602568131061NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3602569131061NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3602570131061NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3602571131061NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3602572131061NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3602573131061NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3602574131061NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3602575131061NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3602576131061NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3602577131061NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3602578131061NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3602579131061NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3602580131061NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3602581131061NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3602582131061NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3602583131061NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3602584131061NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3602585131061NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3602586131061NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3602587131061NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3602588131061NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3602589131061NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3602590131061NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3602591131061NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3602592131061NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3602593131061NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3602594131061NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3602595131061NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3602596131061NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3602597131061NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3602598131061NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3602599131061NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3602600131061NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3602601131061NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3602602131061NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3602603131061NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3602604131061NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3602605131061NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3602606131061NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3602607131061NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3602608131061NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3602609131061NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3602610131061NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3602611131061NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3602612131061NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3602613131061NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3602614131061NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3602615131061NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3602616131061NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3602617131061NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3602618131061NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3602619131061NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3602620131061NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3602621131061NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3602622131061NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3602623131061NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3602624131061NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3602625131061NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3602626131061NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3602627131061NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3602628131061NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3602629131061NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3602630131061NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3602631131061NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3602632131061NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3602633131061NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3602634131061NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3602635131061NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3602636131061NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3602637131061NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3602638131061NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3602639131061NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3602640131061NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3602641131061NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3602642131061NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3602643131061NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3602644131061NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3602645131061NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3602646131061NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3602647131061NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3602648131061NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3602649131061NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3602650131061NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3602651131061NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3602652131061NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3602653131061NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3602654131061NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3602655131061NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3602656131061NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3602657131061NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3602658131061NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3602659131061NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3602660131061NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3602661131061NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3602662131061NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3602663131061NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3602664131061NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3602665131061NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3602666131061NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3602667131061NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3602668131061NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3602669131061NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3602670131061NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3602671131061NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3602672131061NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3602673131061NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3602674131061NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3602675131061NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3602676131061NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3602677131061NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3602678131061NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3602679131061NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3602680131061NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3602681131061NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3602682131061NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3602683131061NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3602684131061NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3602685131061NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3602686131061NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3602687131061NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3602688131061NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3602689131061NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3602690131061NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3602691131061NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3602692131061NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3602693131061NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3602694131061NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3602695131061NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3602696131061NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3602697131061NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3602698131061NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3602699131061NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3602700131061NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3602701131061NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3602702131061NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3602703131061NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3602704131061NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3602705131061NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3602706131061NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3602707131061NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3602708131061NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3602709131061NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3602710131061NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3602711131061NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3602712131061NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3602713131061NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3602714131061NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3602715131061NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3602716131061NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3602717131061NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3602718131061NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3602719131061NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3602720131061NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3602721131061NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3602722131061NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3602723131061NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3602724131061NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3602725131061NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3602726131061NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3602727131061NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3602728131061NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3602729131061NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3602730131061NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3602731131061NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3602732131061NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3602733131061NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3602734131061NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3602735131061NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3602736131061NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3602737131061NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3602738131061NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3602739131061NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3602740131061NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3602741131061NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3602742131061NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3602743131061NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3602744131061NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3602745131061NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3602746131061NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3602747131061NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3602748131061NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3602749131061NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3602750131061NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3602751131061NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3602752131061NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3602753131061NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3602754131061NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3602755131061NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3602756131061NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3602757131061NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3602758131061NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3602759131061NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3602760131061NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3602761131061NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3602762131061NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3602763131061NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3602764131061NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3602765131061NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3602766131061NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3602767131061NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3602768131061NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3602769131061NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3602770131061NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3602771131061NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3602772131061NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3602773131061NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3602774131061NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3602775131061NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3602776131061NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3602777131061NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3602778131061NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3602779131061NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3602780131061NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3602781131061NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3602782131061NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3602783131061NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3602784131061NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3602785131061NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3602786131061NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3602787131061NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3602788131061NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3602789131061NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3602790131061NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3602791131061NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3602792131061NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3602793131061NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3602794131061NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3602795131061NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3602796131061NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3602797131061NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3602798131061NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3602799131061NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3602800131061NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3602801131061NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3602802131061NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3602803131061NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3602804131061NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3602805131061NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3602806131061NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3602807131061NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3602808131061NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3602809131061NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3602810131061NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3602811131061NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3602812131061NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3602813131061NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3602814131061NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3602815131061NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3602816131061NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3602817131061NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3602818131061NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3602819131061NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3602820131061NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3602821131061NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3602822131061NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3602823131061NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3602824131061NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3602825131061NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3602826131061NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3602827131061NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3602828131061NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3602829131061NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3602830131061NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3602831131061NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3602832131061NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3602833131061NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3602834131061NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3602835131061NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3602836131061NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3602837131061NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3602838131061NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3602839131061NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3602840131061NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3602841131061NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3602842131061NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3602843131061NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3602844131061NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3602845131061NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3602846131061NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3602847131061NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3602848131061NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3602849131061NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3602850131061NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3602851131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3602852131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3602853131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3602854131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3602855131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3602856131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3602857131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3602858131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3602859131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3602860131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3602861131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3602862131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3602863131061NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3602864131061NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3602865131061NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3602866131061NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3602867131061NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3602868131061NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3602869131061NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3602870131061NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3602871131061NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3602872131061NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3602873131061NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3602874131061NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3602875131061NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3602876131061NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3602877131061NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3602878131061NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3602879131061NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3602880131061NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3602881131061NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3602882131061NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3602883131061NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3602884131061NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3602885131061NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3602886131061NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3602887131061NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3602888131061NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3602889131061NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3602890131061NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3602891131061NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3602892131061NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3602893131061NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3602894131061NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3602895131061NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3602896131061NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3602897131061NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3602898131061NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3602899131061NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3602900131061NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3602901131061NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3602902131061NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3602903131061NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3602904131061NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3602905131061NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3602906131061NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3602907131061NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3602908131061NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3602909131061NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3602910131061NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3602911131061NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3602912131061NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3602913131061NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3602914131061NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3602915131061NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3602916131061NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3602917131061NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3602918131061NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3602919131061NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3602920131061NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3602921131061NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3602922131061NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3602923131061NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3602924131061NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3602925131061NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3602926131061NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3602927131061NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3602928131061NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3602929131061NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3602930131061NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3602931131061NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3602932131061NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3602933131061NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3602934131061NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3602935131061NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3602936131061NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3602937131061NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3602938131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3602939131061NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3602940131061NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3602941131061NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3602942131061NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3602943131061NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3602944131061NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3602945131061NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3602946131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3602947131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3602948131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3602949131061NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3602950131061NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3602951131061NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3602952131061NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3602953131061NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3602954131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3602955131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3602956131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3602957131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3602958131061NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3602959131061NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3602960131061NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3602961131061NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3602962131061NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3602963131061NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3602964131061NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3602965131061NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3602966131061NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3602967131061NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3602968131061NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3602969131061NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3602970131061NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3602971131061NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3602972131061NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3602973131061NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3602974131061NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3602975131061NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3602976131061NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3602977131061NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3602978131061NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3602979131061NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3602980131061NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3602981131061NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3602982131061NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3602983131061NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3602984131061NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3602985131061NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3602986131061NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3602987131061NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3602988131061NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3602989131061NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3602990131061NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3602991131061NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3602992131061NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3602993131061NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3602994131061NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3602995131061NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3602996131061NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3602997131061NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3602998131061NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3602999131061NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3603000131061NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3603001131061NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3603002131061NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3603003131061NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3603004131061NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3603005131061NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3603006131061NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3603007131061NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3603008131061NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3603009131061NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3603010131061NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3603011131061NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3603012131061NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3603013131061NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3603014131061NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3603015131061NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3603016131061NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3603017131061NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3603018131061NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3603019131061NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3603020131061NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3603021131061NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3603022131061NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3603023131061NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3603024131061NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3603025131061NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3603026131061NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3603027131061NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3603028131061NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3603029131061NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3603030131061NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3603031131061NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3603032131061NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3603033131061NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3603034131061NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3603035131061NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3603036131061NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3603037131061NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3603038131061NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3603039131061NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3603040131061NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3603041131061Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218103610000NoneNoneBuildingsConstruction of primary health centre at hirebannigol, in kushtagi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3603042131062NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3603043131062NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3603044131062NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3603045131062NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3603046131062NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3603047131062NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3603048131062NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3603049131062NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3603050131062NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3603051131062NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3603052131062NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3603053131062NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3603054131062NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3603055131062NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3603056131062NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3603057131062NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3603058131062NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3603059131062NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3603060131062NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3603061131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3603062131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3603063131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3603064131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3603065131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3603066131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3603067131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3603068131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3603069131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3603070131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3603071131062NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3603072131062NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3603073131062NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3603074131062NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3603075131062NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3603076131062NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3603077131062NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3603078131062NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3603079131062NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3603080131062NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3603081131062NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3603082131062NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3603083131062NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3603084131062NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3603085131062NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3603086131062NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3603087131062NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3603088131062NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3603089131062NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3603090131062NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3603091131062NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3603092131062NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3603093131062NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3603094131062NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3603095131062NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3603096131062NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3603097131062NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3603098131062NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3603099131062NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3603100131062NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3603101131062NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3603102131062NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3603103131062NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3603104131062NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3603105131062NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3603106131062NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3603107131062NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3603108131062NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3603109131062NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3603110131062NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3603111131062NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3603112131062NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3603113131062NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3603114131062NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3603115131062NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3603116131062NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3603117131062NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3603118131062NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3603119131062NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3603120131062NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3603121131062NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3603122131062NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3603123131062NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3603124131062NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3603125131062NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3603126131062NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3603127131062NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3603128131062NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3603129131062NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3603130131062NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3603131131062NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3603132131062NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3603133131062NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3603134131062NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3603135131062NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3603136131062NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3603137131062NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3603138131062NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3603139131062NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3603140131062NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3603141131062NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3603142131062NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3603143131062NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3603144131062NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3603145131062NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3603146131062NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3603147131062NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3603148131062NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3603149131062NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3603150131062NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3603151131062NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3603152131062NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3603153131062NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3603154131062NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3603155131062NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3603156131062NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3603157131062NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3603158131062NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3603159131062NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3603160131062NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3603161131062NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3603162131062NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3603163131062NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3603164131062NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3603165131062NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3603166131062NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3603167131062NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3603168131062NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3603169131062NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3603170131062NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3603171131062NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3603172131062NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3603173131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3603174131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3603175131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3603176131062NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3603177131062NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3603178131062NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3603179131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3603180131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3603181131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3603182131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3603183131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3603184131062NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3603185131062NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3603186131062NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3603187131062NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3603188131062NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3603189131062NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3603190131062NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3603191131062NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3603192131062NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3603193131062NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3603194131062NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3603195131062NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3603196131062NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3603197131062NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3603198131062NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3603199131062NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3603200131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3603201131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3603202131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3603203131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3603204131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3603205131062NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3603206131062NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3603207131062NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3603208131062NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3603209131062NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3603210131062NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3603211131062NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3603212131062NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3603213131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3603214131062NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3603215131062NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3603216131062NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3603217131062NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3603218131062NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3603219131062NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3603220131062NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3603221131062NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3603222131062NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3603223131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3603224131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3603225131062NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3603226131062NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3603227131062NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3603228131062NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3603229131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3603230131062NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3603231131062NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3603232131062NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3603233131062NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3603234131062NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3603235131062NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3603236131062NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3603237131062NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3603238131062NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3603239131062NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3603240131062NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3603241131062NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3603242131062NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3603243131062NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3603244131062NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3603245131062NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3603246131062NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3603247131062NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3603248131062NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3603249131062NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3603250131062NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3603251131062NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3603252131062NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3603253131062NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3603254131062NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3603255131062NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3603256131062NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3603257131062NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3603258131062NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3603259131062NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3603260131062NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3603261131062NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3603262131062NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3603263131062NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3603264131062NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3603265131062NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3603266131062NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3603267131062NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3603268131062NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3603269131062NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3603270131062NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3603271131062NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3603272131062NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3603273131062NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3603274131062NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3603275131062NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3603276131062NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3603277131062NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3603278131062NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3603279131062NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3603280131062NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3603281131062NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3603282131062NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3603283131062NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3603284131062NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3603285131062NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3603286131062NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3603287131062NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3603288131062NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3603289131062NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3603290131062NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3603291131062NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3603292131062NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3603293131062NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3603294131062NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3603295131062NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3603296131062NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3603297131062NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3603298131062NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3603299131062NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3603300131062NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3603301131062NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3603302131062NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3603303131062NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3603304131062NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3603305131062NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3603306131062NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3603307131062NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3603308131062NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3603309131062NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3603310131062NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3603311131062NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3603312131062NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3603313131062NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3603314131062NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3603315131062NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3603316131062NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3603317131062NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3603318131062NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3603319131062NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3603320131062NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3603321131062NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3603322131062NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3603323131062NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3603324131062NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3603325131062NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3603326131062NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3603327131062NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3603328131062NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3603329131062NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3603330131062NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3603331131062NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3603332131062NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3603333131062NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3603334131062NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3603335131062NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3603336131062NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3603337131062NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3603338131062NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3603339131062NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3603340131062NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3603341131062NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3603342131062NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3603343131062NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3603344131062NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3603345131062NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3603346131062NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3603347131062NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3603348131062NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3603349131062NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3603350131062NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3603351131062NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3603352131062NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3603353131062NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3603354131062NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3603355131062NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3603356131062NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3603357131062NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3603358131062NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3603359131062NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3603360131062NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3603361131062NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3603362131062NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3603363131062NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3603364131062NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3603365131062NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3603366131062NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3603367131062NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3603368131062NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3603369131062NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3603370131062NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3603371131062NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3603372131062NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3603373131062NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3603374131062NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3603375131062NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3603376131062NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3603377131062NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3603378131062NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3603379131062NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3603380131062NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3603381131062NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3603382131062NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3603383131062NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3603384131062NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3603385131062NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3603386131062NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3603387131062NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3603388131062NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3603389131062NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3603390131062NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3603391131062NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3603392131062NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3603393131062NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3603394131062NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3603395131062NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3603396131062NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3603397131062NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3603398131062NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3603399131062NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3603400131062NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3603401131062NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3603402131062NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3603403131062NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3603404131062NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3603405131062NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3603406131062NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3603407131062NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3603408131062NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3603409131062NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3603410131062NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3603411131062NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3603412131062NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3603413131062NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3603414131062NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3603415131062NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3603416131062NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3603417131062NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3603418131062NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3603419131062NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3603420131062NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3603421131062NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3603422131062NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3603423131062NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3603424131062NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3603425131062NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3603426131062NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3603427131062NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3603428131062NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3603429131062NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3603430131062NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3603431131062NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3603432131062NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3603433131062NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3603434131062NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3603435131062NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3603436131062NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3603437131062NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3603438131062NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3603439131062NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3603440131062NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3603441131062NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3603442131062NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3603443131062NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3603444131062NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3603445131062NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3603446131062NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3603447131062NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3603448131062NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3603449131062NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3603450131062NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3603451131062NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3603452131062NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3603453131062NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3603454131062NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3603455131062NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3603456131062NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3603457131062NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3603458131062NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3603459131062NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3603460131062NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3603461131062NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3603462131062NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3603463131062NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3603464131062NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3603465131062NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3603466131062NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3603467131062NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3603468131062NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3603469131062NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3603470131062NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3603471131062NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3603472131062NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3603473131062NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3603474131062NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3603475131062NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3603476131062NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3603477131062NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3603478131062NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3603479131062NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3603480131062NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3603481131062NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3603482131062NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3603483131062NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3603484131062NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3603485131062NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3603486131062NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3603487131062NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3603488131062NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3603489131062NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3603490131062NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3603491131062NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3603492131062NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3603493131062NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3603494131062NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3603495131062NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3603496131062NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3603497131062NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3603498131062NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3603499131062NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3603500131062NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3603501131062NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3603502131062NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3603503131062NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3603504131062NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3603505131062NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3603506131062NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3603507131062NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3603508131062NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3603509131062NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3603510131062NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3603511131062NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3603512131062NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3603513131062NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3603514131062NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3603515131062NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3603516131062NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3603517131062NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3603518131062NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3603519131062NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3603520131062NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3603521131062NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3603522131062NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3603523131062NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3603524131062NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3603525131062NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3603526131062NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3603527131062NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3603528131062NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3603529131062NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3603530131062NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3603531131062NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3603532131062NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3603533131062NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3603534131062NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3603535131062NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3603536131062NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3603537131062NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3603538131062NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3603539131062NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3603540131062NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3603541131062NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3603542131062NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3603543131062NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3603544131062NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3603545131062NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3603546131062NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3603547131062NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3603548131062NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3603549131062NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3603550131062NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3603551131062NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3603552131062NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3603553131062NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3603554131062NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3603555131062NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3603556131062NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3603557131062NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3603558131062NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3603559131062NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3603560131062NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3603561131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3603562131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3603563131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3603564131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3603565131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3603566131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3603567131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3603568131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3603569131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3603570131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3603571131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3603572131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3603573131062NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3603574131062NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3603575131062NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3603576131062NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3603577131062NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3603578131062NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3603579131062NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3603580131062NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3603581131062NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3603582131062NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3603583131062NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3603584131062NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3603585131062NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3603586131062NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3603587131062NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3603588131062NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3603589131062NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3603590131062NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3603591131062NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3603592131062NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3603593131062NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3603594131062NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3603595131062NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3603596131062NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3603597131062NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3603598131062NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3603599131062NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3603600131062NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3603601131062NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3603602131062NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3603603131062NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3603604131062NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3603605131062NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3603606131062NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3603607131062NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3603608131062NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3603609131062NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3603610131062NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3603611131062NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3603612131062NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3603613131062NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3603614131062NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3603615131062NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3603616131062NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3603617131062NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3603618131062NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3603619131062NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3603620131062NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3603621131062NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3603622131062NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3603623131062NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3603624131062NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3603625131062NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3603626131062NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3603627131062NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3603628131062NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3603629131062NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3603630131062NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3603631131062NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3603632131062NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3603633131062NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3603634131062NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3603635131062NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3603636131062NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3603637131062NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3603638131062NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3603639131062NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3603640131062NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3603641131062NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3603642131062NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3603643131062NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3603644131062NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3603645131062NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3603646131062NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3603647131062NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3603648131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3603649131062NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3603650131062NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3603651131062NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3603652131062NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3603653131062NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3603654131062NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3603655131062NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3603656131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3603657131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3603658131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3603659131062NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3603660131062NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3603661131062NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3603662131062NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3603663131062NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3603664131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3603665131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3603666131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3603667131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3603668131062NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3603669131062NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3603670131062NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3603671131062NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3603672131062NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3603673131062NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3603674131062NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3603675131062NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3603676131062NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3603677131062NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3603678131062NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3603679131062NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3603680131062NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3603681131062NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3603682131062NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3603683131062NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3603684131062NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3603685131062NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3603686131062NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3603687131062NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3603688131062NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3603689131062NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3603690131062NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3603691131062NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3603692131062NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3603693131062NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3603694131062NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3603695131062NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3603696131062NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3603697131062NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3603698131062NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3603699131062NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3603700131062NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3603701131062NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3603702131062NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3603703131062NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3603704131062NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3603705131062NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3603706131062NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3603707131062NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3603708131062NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3603709131062NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3603710131062NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3603711131062NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3603712131062NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3603713131062NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3603714131062NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3603715131062NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3603716131062NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3603717131062NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3603718131062NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3603719131062NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3603720131062NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3603721131062NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3603722131062NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3603723131062NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3603724131062NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3603725131062NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3603726131062NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3603727131062NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3603728131062NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3603729131062NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3603730131062NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3603731131062NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3603732131062NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3603733131062NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3603734131062NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3603735131062NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3603736131062NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3603737131062NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3603738131062NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3603739131062NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3603740131062NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3603741131062NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3603742131062NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3603743131062NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3603744131062NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3603745131062NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3603746131062NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3603747131062NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3603748131062NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3603749131062NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3603750131062NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3603751131062Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218103620000NoneNoneBuildingsConstruction of primary health centre at singanala, in gangavathi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3603752131063NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3603753131063NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3603754131063NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3603755131063NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3603756131063NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3603757131063NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3603758131063NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3603759131063NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3603760131063NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3603761131063NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3603762131063NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3603763131063NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3603764131063NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3603765131063NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3603766131063NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3603767131063NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3603768131063NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3603769131063NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3603770131063NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3603771131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3603772131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3603773131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3603774131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3603775131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3603776131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3603777131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3603778131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3603779131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3603780131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3603781131063NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3603782131063NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3603783131063NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3603784131063NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3603785131063NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3603786131063NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3603787131063NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3603788131063NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3603789131063NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3603790131063NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3603791131063NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3603792131063NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3603793131063NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3603794131063NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3603795131063NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3603796131063NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3603797131063NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3603798131063NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3603799131063NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3603800131063NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3603801131063NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3603802131063NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3603803131063NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3603804131063NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3603805131063NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3603806131063NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3603807131063NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3603808131063NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3603809131063NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3603810131063NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3603811131063NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3603812131063NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3603813131063NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3603814131063NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3603815131063NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3603816131063NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3603817131063NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3603818131063NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3603819131063NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3603820131063NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3603821131063NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3603822131063NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3603823131063NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3603824131063NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3603825131063NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3603826131063NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3603827131063NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3603828131063NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3603829131063NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3603830131063NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3603831131063NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3603832131063NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3603833131063NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3603834131063NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3603835131063NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3603836131063NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3603837131063NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3603838131063NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3603839131063NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3603840131063NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3603841131063NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3603842131063NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3603843131063NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3603844131063NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3603845131063NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3603846131063NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3603847131063NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3603848131063NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3603849131063NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3603850131063NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3603851131063NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3603852131063NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3603853131063NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3603854131063NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3603855131063NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3603856131063NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3603857131063NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3603858131063NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3603859131063NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3603860131063NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3603861131063NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3603862131063NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3603863131063NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3603864131063NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3603865131063NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3603866131063NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3603867131063NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3603868131063NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3603869131063NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3603870131063NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3603871131063NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3603872131063NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3603873131063NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3603874131063NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3603875131063NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3603876131063NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3603877131063NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3603878131063NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3603879131063NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3603880131063NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3603881131063NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3603882131063NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3603883131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3603884131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3603885131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3603886131063NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3603887131063NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3603888131063NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3603889131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3603890131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3603891131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3603892131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3603893131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3603894131063NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3603895131063NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3603896131063NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3603897131063NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3603898131063NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3603899131063NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3603900131063NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3603901131063NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3603902131063NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3603903131063NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3603904131063NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3603905131063NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3603906131063NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3603907131063NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3603908131063NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3603909131063NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3603910131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3603911131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3603912131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3603913131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3603914131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3603915131063NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3603916131063NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3603917131063NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3603918131063NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3603919131063NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3603920131063NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3603921131063NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3603922131063NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3603923131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3603924131063NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3603925131063NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3603926131063NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3603927131063NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3603928131063NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3603929131063NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3603930131063NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3603931131063NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3603932131063NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3603933131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3603934131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3603935131063NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3603936131063NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3603937131063NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3603938131063NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3603939131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3603940131063NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3603941131063NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3603942131063NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3603943131063NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3603944131063NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3603945131063NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3603946131063NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3603947131063NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3603948131063NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3603949131063NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3603950131063NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3603951131063NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3603952131063NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3603953131063NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3603954131063NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3603955131063NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3603956131063NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3603957131063NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3603958131063NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3603959131063NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3603960131063NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3603961131063NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3603962131063NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3603963131063NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3603964131063NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3603965131063NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3603966131063NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3603967131063NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3603968131063NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3603969131063NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3603970131063NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3603971131063NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3603972131063NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3603973131063NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3603974131063NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3603975131063NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3603976131063NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3603977131063NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3603978131063NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3603979131063NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3603980131063NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3603981131063NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3603982131063NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3603983131063NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3603984131063NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3603985131063NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3603986131063NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3603987131063NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3603988131063NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3603989131063NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3603990131063NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3603991131063NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3603992131063NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3603993131063NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3603994131063NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3603995131063NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3603996131063NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3603997131063NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3603998131063NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3603999131063NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3604000131063NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3604001131063NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3604002131063NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3604003131063NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3604004131063NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3604005131063NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3604006131063NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3604007131063NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3604008131063NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3604009131063NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3604010131063NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3604011131063NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3604012131063NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3604013131063NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3604014131063NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3604015131063NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3604016131063NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3604017131063NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3604018131063NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3604019131063NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3604020131063NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3604021131063NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3604022131063NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3604023131063NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3604024131063NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3604025131063NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3604026131063NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3604027131063NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3604028131063NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3604029131063NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3604030131063NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3604031131063NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3604032131063NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3604033131063NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3604034131063NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3604035131063NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3604036131063NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3604037131063NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3604038131063NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3604039131063NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3604040131063NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3604041131063NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3604042131063NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3604043131063NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3604044131063NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3604045131063NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3604046131063NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3604047131063NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3604048131063NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3604049131063NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3604050131063NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3604051131063NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3604052131063NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3604053131063NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3604054131063NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3604055131063NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3604056131063NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3604057131063NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3604058131063NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3604059131063NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3604060131063NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3604061131063NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3604062131063NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3604063131063NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3604064131063NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3604065131063NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3604066131063NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3604067131063NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3604068131063NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3604069131063NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3604070131063NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3604071131063NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3604072131063NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3604073131063NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3604074131063NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3604075131063NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3604076131063NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3604077131063NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3604078131063NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3604079131063NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3604080131063NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3604081131063NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3604082131063NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3604083131063NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3604084131063NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3604085131063NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3604086131063NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3604087131063NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3604088131063NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3604089131063NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3604090131063NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3604091131063NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3604092131063NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3604093131063NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3604094131063NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3604095131063NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3604096131063NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3604097131063NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3604098131063NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3604099131063NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3604100131063NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3604101131063NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3604102131063NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3604103131063NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3604104131063NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3604105131063NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3604106131063NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3604107131063NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3604108131063NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3604109131063NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3604110131063NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3604111131063NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3604112131063NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3604113131063NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3604114131063NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3604115131063NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3604116131063NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3604117131063NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3604118131063NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3604119131063NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3604120131063NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3604121131063NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3604122131063NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3604123131063NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3604124131063NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3604125131063NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3604126131063NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3604127131063NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3604128131063NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3604129131063NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3604130131063NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3604131131063NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3604132131063NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3604133131063NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3604134131063NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3604135131063NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3604136131063NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3604137131063NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3604138131063NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3604139131063NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3604140131063NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3604141131063NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3604142131063NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3604143131063NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3604144131063NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3604145131063NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3604146131063NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3604147131063NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3604148131063NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3604149131063NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3604150131063NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3604151131063NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3604152131063NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3604153131063NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3604154131063NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3604155131063NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3604156131063NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3604157131063NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3604158131063NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3604159131063NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3604160131063NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3604161131063NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3604162131063NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3604163131063NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3604164131063NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3604165131063NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3604166131063NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3604167131063NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3604168131063NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3604169131063NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3604170131063NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3604171131063NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3604172131063NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3604173131063NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3604174131063NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3604175131063NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3604176131063NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3604177131063NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3604178131063NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3604179131063NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3604180131063NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3604181131063NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3604182131063NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3604183131063NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3604184131063NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3604185131063NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3604186131063NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3604187131063NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3604188131063NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3604189131063NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3604190131063NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3604191131063NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3604192131063NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3604193131063NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3604194131063NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3604195131063NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3604196131063NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3604197131063NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3604198131063NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3604199131063NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3604200131063NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3604201131063NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3604202131063NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3604203131063NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3604204131063NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3604205131063NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3604206131063NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3604207131063NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3604208131063NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3604209131063NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3604210131063NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3604211131063NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3604212131063NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3604213131063NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3604214131063NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3604215131063NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3604216131063NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3604217131063NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3604218131063NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3604219131063NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3604220131063NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3604221131063NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3604222131063NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3604223131063NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3604224131063NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3604225131063NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3604226131063NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3604227131063NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3604228131063NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3604229131063NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3604230131063NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3604231131063NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3604232131063NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3604233131063NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3604234131063NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3604235131063NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3604236131063NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3604237131063NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3604238131063NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3604239131063NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3604240131063NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3604241131063NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3604242131063NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3604243131063NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3604244131063NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3604245131063NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3604246131063NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3604247131063NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3604248131063NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3604249131063NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3604250131063NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3604251131063NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3604252131063NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3604253131063NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3604254131063NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3604255131063NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3604256131063NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3604257131063NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3604258131063NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3604259131063NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3604260131063NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3604261131063NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3604262131063NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3604263131063NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3604264131063NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3604265131063NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3604266131063NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3604267131063NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3604268131063NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3604269131063NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3604270131063NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3604271131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3604272131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3604273131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3604274131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3604275131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3604276131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3604277131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3604278131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3604279131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3604280131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3604281131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3604282131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3604283131063NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3604284131063NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3604285131063NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3604286131063NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3604287131063NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3604288131063NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3604289131063NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3604290131063NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3604291131063NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3604292131063NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3604293131063NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3604294131063NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3604295131063NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3604296131063NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3604297131063NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3604298131063NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3604299131063NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3604300131063NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3604301131063NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3604302131063NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3604303131063NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3604304131063NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3604305131063NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3604306131063NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3604307131063NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3604308131063NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3604309131063NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3604310131063NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3604311131063NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3604312131063NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3604313131063NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3604314131063NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3604315131063NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3604316131063NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3604317131063NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3604318131063NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3604319131063NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3604320131063NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3604321131063NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3604322131063NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3604323131063NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3604324131063NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3604325131063NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3604326131063NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3604327131063NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3604328131063NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3604329131063NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3604330131063NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3604331131063NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3604332131063NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3604333131063NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3604334131063NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3604335131063NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3604336131063NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3604337131063NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3604338131063NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3604339131063NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3604340131063NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3604341131063NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3604342131063NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3604343131063NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3604344131063NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3604345131063NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3604346131063NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3604347131063NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3604348131063NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3604349131063NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3604350131063NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3604351131063NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3604352131063NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3604353131063NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3604354131063NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3604355131063NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3604356131063NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3604357131063NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3604358131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3604359131063NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3604360131063NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3604361131063NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3604362131063NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3604363131063NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3604364131063NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3604365131063NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3604366131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3604367131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3604368131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3604369131063NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3604370131063NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3604371131063NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3604372131063NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3604373131063NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3604374131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3604375131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3604376131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3604377131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3604378131063NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3604379131063NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3604380131063NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3604381131063NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3604382131063NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3604383131063NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3604384131063NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3604385131063NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3604386131063NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3604387131063NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3604388131063NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3604389131063NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3604390131063NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3604391131063NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3604392131063NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3604393131063NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3604394131063NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3604395131063NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3604396131063NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3604397131063NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3604398131063NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3604399131063NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3604400131063NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3604401131063NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3604402131063NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3604403131063NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3604404131063NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3604405131063NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3604406131063NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3604407131063NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3604408131063NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3604409131063NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3604410131063NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3604411131063NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3604412131063NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3604413131063NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3604414131063NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3604415131063NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3604416131063NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3604417131063NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3604418131063NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3604419131063NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3604420131063NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3604421131063NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3604422131063NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3604423131063NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3604424131063NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3604425131063NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3604426131063NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3604427131063NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3604428131063NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3604429131063NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3604430131063NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3604431131063NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3604432131063NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3604433131063NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3604434131063NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3604435131063NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3604436131063NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3604437131063NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3604438131063NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3604439131063NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3604440131063NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3604441131063NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3604442131063NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3604443131063NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3604444131063NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3604445131063NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3604446131063NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3604447131063NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3604448131063NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3604449131063NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3604450131063NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3604451131063NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3604452131063NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3604453131063NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3604454131063NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3604455131063NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3604456131063NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3604457131063NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3604458131063NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3604459131063NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3604460131063NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3604461131063Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218103620000NoneNoneBuildingsConstruction of primary health centre at jeeral, in gangavathi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3604462131064NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3604463131064NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3604464131064NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3604465131064NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3604466131064NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3604467131064NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3604468131064NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3604469131064NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3604470131064NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3604471131064NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3604472131064NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3604473131064NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3604474131064NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3604475131064NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3604476131064NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3604477131064NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3604478131064NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3604479131064NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3604480131064NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3604481131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3604482131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3604483131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3604484131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3604485131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3604486131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3604487131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3604488131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3604489131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3604490131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3604491131064NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3604492131064NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3604493131064NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3604494131064NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3604495131064NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3604496131064NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3604497131064NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3604498131064NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3604499131064NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3604500131064NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3604501131064NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3604502131064NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3604503131064NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3604504131064NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3604505131064NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3604506131064NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3604507131064NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3604508131064NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3604509131064NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3604510131064NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3604511131064NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3604512131064NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3604513131064NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3604514131064NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3604515131064NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3604516131064NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3604517131064NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3604518131064NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3604519131064NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3604520131064NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3604521131064NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3604522131064NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3604523131064NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3604524131064NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3604525131064NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3604526131064NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3604527131064NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3604528131064NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3604529131064NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3604530131064NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3604531131064NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3604532131064NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3604533131064NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3604534131064NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3604535131064NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3604536131064NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3604537131064NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3604538131064NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3604539131064NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3604540131064NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3604541131064NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3604542131064NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3604543131064NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3604544131064NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3604545131064NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3604546131064NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3604547131064NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3604548131064NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3604549131064NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3604550131064NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3604551131064NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3604552131064NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3604553131064NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3604554131064NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3604555131064NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3604556131064NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3604557131064NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3604558131064NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3604559131064NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3604560131064NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3604561131064NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3604562131064NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3604563131064NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3604564131064NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3604565131064NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3604566131064NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3604567131064NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3604568131064NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3604569131064NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3604570131064NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3604571131064NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3604572131064NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3604573131064NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3604574131064NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3604575131064NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3604576131064NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3604577131064NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3604578131064NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3604579131064NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3604580131064NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3604581131064NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3604582131064NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3604583131064NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3604584131064NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3604585131064NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3604586131064NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3604587131064NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3604588131064NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3604589131064NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3604590131064NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3604591131064NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3604592131064NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3604593131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3604594131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3604595131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3604596131064NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3604597131064NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3604598131064NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3604599131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3604600131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3604601131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3604602131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3604603131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3604604131064NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3604605131064NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3604606131064NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3604607131064NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3604608131064NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3604609131064NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3604610131064NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3604611131064NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3604612131064NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3604613131064NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3604614131064NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3604615131064NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3604616131064NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3604617131064NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3604618131064NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3604619131064NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3604620131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3604621131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3604622131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3604623131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3604624131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3604625131064NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3604626131064NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3604627131064NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3604628131064NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3604629131064NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3604630131064NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3604631131064NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3604632131064NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3604633131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3604634131064NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3604635131064NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3604636131064NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3604637131064NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3604638131064NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3604639131064NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3604640131064NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3604641131064NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3604642131064NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3604643131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3604644131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3604645131064NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3604646131064NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3604647131064NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3604648131064NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3604649131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3604650131064NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3604651131064NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3604652131064NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3604653131064NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3604654131064NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3604655131064NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3604656131064NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3604657131064NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3604658131064NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3604659131064NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3604660131064NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3604661131064NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3604662131064NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3604663131064NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3604664131064NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3604665131064NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3604666131064NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3604667131064NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3604668131064NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3604669131064NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3604670131064NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3604671131064NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3604672131064NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3604673131064NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3604674131064NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3604675131064NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3604676131064NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3604677131064NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3604678131064NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3604679131064NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3604680131064NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3604681131064NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3604682131064NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3604683131064NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3604684131064NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3604685131064NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3604686131064NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3604687131064NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3604688131064NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3604689131064NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3604690131064NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3604691131064NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3604692131064NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3604693131064NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3604694131064NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3604695131064NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3604696131064NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3604697131064NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3604698131064NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3604699131064NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3604700131064NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3604701131064NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3604702131064NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3604703131064NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3604704131064NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3604705131064NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3604706131064NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3604707131064NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3604708131064NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3604709131064NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3604710131064NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3604711131064NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3604712131064NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3604713131064NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3604714131064NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3604715131064NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3604716131064NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3604717131064NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3604718131064NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3604719131064NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3604720131064NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3604721131064NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3604722131064NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3604723131064NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3604724131064NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3604725131064NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3604726131064NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3604727131064NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3604728131064NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3604729131064NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3604730131064NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3604731131064NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3604732131064NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3604733131064NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3604734131064NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3604735131064NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3604736131064NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3604737131064NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3604738131064NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3604739131064NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3604740131064NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3604741131064NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3604742131064NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3604743131064NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3604744131064NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3604745131064NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3604746131064NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3604747131064NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3604748131064NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3604749131064NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3604750131064NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3604751131064NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3604752131064NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3604753131064NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3604754131064NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3604755131064NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3604756131064NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3604757131064NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3604758131064NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3604759131064NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3604760131064NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3604761131064NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3604762131064NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3604763131064NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3604764131064NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3604765131064NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3604766131064NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3604767131064NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3604768131064NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3604769131064NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3604770131064NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3604771131064NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3604772131064NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3604773131064NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3604774131064NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3604775131064NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3604776131064NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3604777131064NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3604778131064NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3604779131064NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3604780131064NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3604781131064NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3604782131064NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3604783131064NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3604784131064NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3604785131064NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3604786131064NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3604787131064NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3604788131064NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3604789131064NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3604790131064NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3604791131064NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3604792131064NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3604793131064NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3604794131064NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3604795131064NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3604796131064NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3604797131064NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3604798131064NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3604799131064NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3604800131064NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3604801131064NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3604802131064NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3604803131064NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3604804131064NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3604805131064NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3604806131064NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3604807131064NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3604808131064NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3604809131064NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3604810131064NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3604811131064NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3604812131064NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3604813131064NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3604814131064NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3604815131064NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3604816131064NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3604817131064NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3604818131064NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3604819131064NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3604820131064NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3604821131064NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3604822131064NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3604823131064NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3604824131064NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3604825131064NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3604826131064NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3604827131064NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3604828131064NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3604829131064NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3604830131064NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3604831131064NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3604832131064NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3604833131064NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3604834131064NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3604835131064NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3604836131064NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3604837131064NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3604838131064NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3604839131064NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3604840131064NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3604841131064NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3604842131064NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3604843131064NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3604844131064NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3604845131064NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3604846131064NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3604847131064NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3604848131064NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3604849131064NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3604850131064NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3604851131064NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3604852131064NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3604853131064NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3604854131064NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3604855131064NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3604856131064NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3604857131064NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3604858131064NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3604859131064NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3604860131064NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3604861131064NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3604862131064NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3604863131064NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3604864131064NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3604865131064NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3604866131064NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3604867131064NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3604868131064NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3604869131064NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3604870131064NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3604871131064NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3604872131064NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3604873131064NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3604874131064NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3604875131064NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3604876131064NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3604877131064NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3604878131064NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3604879131064NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3604880131064NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3604881131064NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3604882131064NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3604883131064NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3604884131064NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3604885131064NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3604886131064NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3604887131064NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3604888131064NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3604889131064NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3604890131064NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3604891131064NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3604892131064NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3604893131064NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3604894131064NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3604895131064NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3604896131064NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3604897131064NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3604898131064NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3604899131064NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3604900131064NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3604901131064NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3604902131064NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3604903131064NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3604904131064NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3604905131064NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3604906131064NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3604907131064NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3604908131064NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3604909131064NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3604910131064NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3604911131064NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3604912131064NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3604913131064NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3604914131064NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3604915131064NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3604916131064NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3604917131064NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3604918131064NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3604919131064NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3604920131064NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3604921131064NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3604922131064NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3604923131064NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3604924131064NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3604925131064NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3604926131064NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3604927131064NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3604928131064NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3604929131064NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3604930131064NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3604931131064NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3604932131064NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3604933131064NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3604934131064NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3604935131064NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3604936131064NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3604937131064NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3604938131064NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3604939131064NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3604940131064NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3604941131064NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3604942131064NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3604943131064NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3604944131064NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3604945131064NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3604946131064NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3604947131064NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3604948131064NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3604949131064NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3604950131064NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3604951131064NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3604952131064NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3604953131064NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3604954131064NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3604955131064NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3604956131064NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3604957131064NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3604958131064NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3604959131064NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3604960131064NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3604961131064NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3604962131064NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3604963131064NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3604964131064NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3604965131064NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3604966131064NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3604967131064NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3604968131064NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3604969131064NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3604970131064NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3604971131064NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3604972131064NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3604973131064NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3604974131064NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3604975131064NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3604976131064NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3604977131064NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3604978131064NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3604979131064NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3604980131064NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3604981131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3604982131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3604983131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3604984131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3604985131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3604986131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3604987131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3604988131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3604989131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3604990131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3604991131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3604992131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3604993131064NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3604994131064NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3604995131064NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3604996131064NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3604997131064NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3604998131064NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3604999131064NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3605000131064NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3605001131064NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3605002131064NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3605003131064NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3605004131064NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3605005131064NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3605006131064NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3605007131064NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3605008131064NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3605009131064NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3605010131064NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3605011131064NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3605012131064NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3605013131064NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3605014131064NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3605015131064NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3605016131064NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3605017131064NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3605018131064NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3605019131064NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3605020131064NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3605021131064NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3605022131064NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3605023131064NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3605024131064NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3605025131064NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3605026131064NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3605027131064NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3605028131064NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3605029131064NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3605030131064NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3605031131064NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3605032131064NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3605033131064NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3605034131064NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3605035131064NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3605036131064NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3605037131064NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3605038131064NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3605039131064NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3605040131064NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3605041131064NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3605042131064NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3605043131064NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3605044131064NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3605045131064NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3605046131064NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3605047131064NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3605048131064NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3605049131064NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3605050131064NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3605051131064NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3605052131064NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3605053131064NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3605054131064NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3605055131064NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3605056131064NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3605057131064NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3605058131064NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3605059131064NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3605060131064NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3605061131064NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3605062131064NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3605063131064NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3605064131064NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3605065131064NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3605066131064NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3605067131064NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3605068131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3605069131064NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3605070131064NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3605071131064NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3605072131064NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3605073131064NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3605074131064NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3605075131064NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3605076131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3605077131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3605078131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3605079131064NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3605080131064NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3605081131064NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3605082131064NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3605083131064NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3605084131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3605085131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3605086131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3605087131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3605088131064NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3605089131064NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3605090131064NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3605091131064NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3605092131064NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3605093131064NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3605094131064NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3605095131064NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3605096131064NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3605097131064NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3605098131064NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3605099131064NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3605100131064NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3605101131064NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3605102131064NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3605103131064NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3605104131064NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3605105131064NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3605106131064NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3605107131064NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3605108131064NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3605109131064NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3605110131064NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3605111131064NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3605112131064NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3605113131064NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3605114131064NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3605115131064NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3605116131064NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3605117131064NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3605118131064NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3605119131064NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3605120131064NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3605121131064NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3605122131064NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3605123131064NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3605124131064NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3605125131064NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3605126131064NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3605127131064NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3605128131064NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3605129131064NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3605130131064NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3605131131064NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3605132131064NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3605133131064NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3605134131064NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3605135131064NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3605136131064NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3605137131064NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3605138131064NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3605139131064NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3605140131064NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3605141131064NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3605142131064NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3605143131064NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3605144131064NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3605145131064NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3605146131064NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3605147131064NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3605148131064NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3605149131064NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3605150131064NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3605151131064NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3605152131064NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3605153131064NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3605154131064NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3605155131064NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3605156131064NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3605157131064NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3605158131064NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3605159131064NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3605160131064NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3605161131064NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3605162131064NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3605163131064NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3605164131064NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3605165131064NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3605166131064NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3605167131064NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3605168131064NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3605169131064NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3605170131064NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3605171131064Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218103620000NoneNoneBuildingsConstruction of primary health centre at basapattana, in gangavathi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3605172131065NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3605173131065NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3605174131065NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3605175131065NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3605176131065NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3605177131065NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3605178131065NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3605179131065NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3605180131065NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3605181131065NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3605182131065NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3605183131065NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3605184131065NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3605185131065NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3605186131065NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3605187131065NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3605188131065NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3605189131065NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3605190131065NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3605191131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3605192131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3605193131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3605194131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3605195131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3605196131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3605197131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3605198131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3605199131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3605200131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3605201131065NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3605202131065NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3605203131065NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3605204131065NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3605205131065NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3605206131065NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3605207131065NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3605208131065NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3605209131065NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3605210131065NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3605211131065NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3605212131065NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3605213131065NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3605214131065NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3605215131065NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3605216131065NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3605217131065NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3605218131065NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3605219131065NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3605220131065NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3605221131065NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3605222131065NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3605223131065NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3605224131065NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3605225131065NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3605226131065NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3605227131065NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3605228131065NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3605229131065NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3605230131065NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3605231131065NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3605232131065NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3605233131065NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3605234131065NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3605235131065NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3605236131065NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3605237131065NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3605238131065NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3605239131065NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3605240131065NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3605241131065NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3605242131065NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3605243131065NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3605244131065NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3605245131065NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3605246131065NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3605247131065NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3605248131065NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3605249131065NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3605250131065NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3605251131065NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3605252131065NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3605253131065NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3605254131065NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3605255131065NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3605256131065NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3605257131065NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3605258131065NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3605259131065NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3605260131065NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3605261131065NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3605262131065NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3605263131065NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3605264131065NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3605265131065NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3605266131065NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3605267131065NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3605268131065NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3605269131065NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3605270131065NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3605271131065NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3605272131065NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3605273131065NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3605274131065NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3605275131065NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3605276131065NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3605277131065NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3605278131065NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3605279131065NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3605280131065NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3605281131065NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3605282131065NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3605283131065NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3605284131065NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3605285131065NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3605286131065NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3605287131065NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3605288131065NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3605289131065NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3605290131065NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3605291131065NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3605292131065NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3605293131065NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3605294131065NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3605295131065NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3605296131065NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3605297131065NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3605298131065NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3605299131065NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3605300131065NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3605301131065NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3605302131065NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3605303131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3605304131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3605305131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3605306131065NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3605307131065NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3605308131065NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3605309131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3605310131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3605311131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3605312131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3605313131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3605314131065NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3605315131065NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3605316131065NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3605317131065NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3605318131065NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3605319131065NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3605320131065NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3605321131065NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3605322131065NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3605323131065NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3605324131065NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3605325131065NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3605326131065NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3605327131065NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3605328131065NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3605329131065NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3605330131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3605331131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3605332131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3605333131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3605334131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3605335131065NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3605336131065NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3605337131065NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3605338131065NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3605339131065NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3605340131065NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3605341131065NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3605342131065NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3605343131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3605344131065NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3605345131065NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3605346131065NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3605347131065NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3605348131065NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3605349131065NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3605350131065NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3605351131065NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3605352131065NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3605353131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3605354131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3605355131065NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3605356131065NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3605357131065NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3605358131065NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3605359131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3605360131065NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3605361131065NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3605362131065NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3605363131065NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3605364131065NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3605365131065NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3605366131065NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3605367131065NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3605368131065NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3605369131065NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3605370131065NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3605371131065NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3605372131065NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3605373131065NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3605374131065NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3605375131065NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3605376131065NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3605377131065NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3605378131065NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3605379131065NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3605380131065NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3605381131065NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3605382131065NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3605383131065NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3605384131065NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3605385131065NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3605386131065NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3605387131065NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3605388131065NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3605389131065NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3605390131065NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3605391131065NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3605392131065NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3605393131065NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3605394131065NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3605395131065NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3605396131065NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3605397131065NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3605398131065NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3605399131065NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3605400131065NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3605401131065NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3605402131065NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3605403131065NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3605404131065NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3605405131065NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3605406131065NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3605407131065NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3605408131065NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3605409131065NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3605410131065NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3605411131065NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3605412131065NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3605413131065NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3605414131065NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3605415131065NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3605416131065NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3605417131065NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3605418131065NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3605419131065NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3605420131065NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3605421131065NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3605422131065NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3605423131065NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3605424131065NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3605425131065NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3605426131065NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3605427131065NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3605428131065NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3605429131065NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3605430131065NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3605431131065NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3605432131065NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3605433131065NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3605434131065NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3605435131065NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3605436131065NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3605437131065NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3605438131065NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3605439131065NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3605440131065NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3605441131065NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3605442131065NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3605443131065NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3605444131065NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3605445131065NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3605446131065NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3605447131065NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3605448131065NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3605449131065NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3605450131065NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3605451131065NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3605452131065NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3605453131065NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3605454131065NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3605455131065NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3605456131065NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3605457131065NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3605458131065NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3605459131065NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3605460131065NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3605461131065NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3605462131065NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3605463131065NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3605464131065NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3605465131065NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3605466131065NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3605467131065NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3605468131065NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3605469131065NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3605470131065NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3605471131065NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3605472131065NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3605473131065NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3605474131065NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3605475131065NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3605476131065NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3605477131065NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3605478131065NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3605479131065NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3605480131065NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3605481131065NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3605482131065NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3605483131065NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3605484131065NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3605485131065NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3605486131065NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3605487131065NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3605488131065NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3605489131065NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3605490131065NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3605491131065NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3605492131065NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3605493131065NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3605494131065NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3605495131065NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3605496131065NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3605497131065NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3605498131065NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3605499131065NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3605500131065NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3605501131065NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3605502131065NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3605503131065NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3605504131065NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3605505131065NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3605506131065NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3605507131065NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3605508131065NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3605509131065NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3605510131065NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3605511131065NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3605512131065NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3605513131065NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3605514131065NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3605515131065NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3605516131065NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3605517131065NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3605518131065NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3605519131065NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3605520131065NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3605521131065NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3605522131065NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3605523131065NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3605524131065NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3605525131065NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3605526131065NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3605527131065NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3605528131065NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3605529131065NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3605530131065NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3605531131065NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3605532131065NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3605533131065NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3605534131065NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3605535131065NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3605536131065NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3605537131065NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3605538131065NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3605539131065NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3605540131065NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3605541131065NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3605542131065NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3605543131065NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3605544131065NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3605545131065NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3605546131065NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3605547131065NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3605548131065NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3605549131065NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3605550131065NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3605551131065NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3605552131065NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3605553131065NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3605554131065NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3605555131065NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3605556131065NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3605557131065NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3605558131065NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3605559131065NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3605560131065NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3605561131065NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3605562131065NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3605563131065NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3605564131065NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3605565131065NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3605566131065NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3605567131065NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3605568131065NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3605569131065NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3605570131065NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3605571131065NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3605572131065NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3605573131065NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3605574131065NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3605575131065NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3605576131065NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3605577131065NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3605578131065NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3605579131065NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3605580131065NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3605581131065NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3605582131065NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3605583131065NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3605584131065NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3605585131065NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3605586131065NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3605587131065NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3605588131065NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3605589131065NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3605590131065NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3605591131065NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3605592131065NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3605593131065NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3605594131065NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3605595131065NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3605596131065NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3605597131065NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3605598131065NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3605599131065NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3605600131065NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3605601131065NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3605602131065NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3605603131065NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3605604131065NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3605605131065NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3605606131065NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3605607131065NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3605608131065NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3605609131065NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3605610131065NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3605611131065NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3605612131065NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3605613131065NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3605614131065NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3605615131065NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3605616131065NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3605617131065NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3605618131065NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3605619131065NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3605620131065NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3605621131065NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3605622131065NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3605623131065NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3605624131065NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3605625131065NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3605626131065NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3605627131065NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3605628131065NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3605629131065NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3605630131065NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3605631131065NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3605632131065NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3605633131065NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3605634131065NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3605635131065NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3605636131065NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3605637131065NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3605638131065NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3605639131065NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3605640131065NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3605641131065NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3605642131065NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3605643131065NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3605644131065NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3605645131065NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3605646131065NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3605647131065NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3605648131065NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3605649131065NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3605650131065NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3605651131065NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3605652131065NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3605653131065NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3605654131065NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3605655131065NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3605656131065NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3605657131065NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3605658131065NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3605659131065NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3605660131065NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3605661131065NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3605662131065NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3605663131065NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3605664131065NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3605665131065NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3605666131065NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3605667131065NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3605668131065NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3605669131065NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3605670131065NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3605671131065NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3605672131065NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3605673131065NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3605674131065NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3605675131065NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3605676131065NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3605677131065NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3605678131065NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3605679131065NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3605680131065NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3605681131065NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3605682131065NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3605683131065NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3605684131065NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3605685131065NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3605686131065NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3605687131065NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3605688131065NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3605689131065NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3605690131065NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3605691131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3605692131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3605693131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3605694131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3605695131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3605696131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3605697131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3605698131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3605699131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3605700131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3605701131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3605702131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3605703131065NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3605704131065NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3605705131065NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3605706131065NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3605707131065NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3605708131065NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3605709131065NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3605710131065NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3605711131065NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3605712131065NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3605713131065NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3605714131065NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3605715131065NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3605716131065NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3605717131065NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3605718131065NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3605719131065NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3605720131065NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3605721131065NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3605722131065NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3605723131065NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3605724131065NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3605725131065NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3605726131065NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3605727131065NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3605728131065NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3605729131065NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3605730131065NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3605731131065NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3605732131065NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3605733131065NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3605734131065NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3605735131065NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3605736131065NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3605737131065NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3605738131065NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3605739131065NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3605740131065NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3605741131065NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3605742131065NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3605743131065NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3605744131065NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3605745131065NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3605746131065NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3605747131065NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3605748131065NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3605749131065NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3605750131065NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3605751131065NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3605752131065NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3605753131065NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3605754131065NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3605755131065NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3605756131065NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3605757131065NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3605758131065NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3605759131065NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3605760131065NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3605761131065NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3605762131065NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3605763131065NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3605764131065NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3605765131065NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3605766131065NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3605767131065NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3605768131065NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3605769131065NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3605770131065NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3605771131065NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3605772131065NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3605773131065NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3605774131065NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3605775131065NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3605776131065NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3605777131065NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3605778131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3605779131065NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3605780131065NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3605781131065NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3605782131065NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3605783131065NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3605784131065NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3605785131065NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3605786131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3605787131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3605788131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3605789131065NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3605790131065NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3605791131065NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3605792131065NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3605793131065NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3605794131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3605795131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3605796131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3605797131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3605798131065NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3605799131065NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3605800131065NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3605801131065NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3605802131065NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3605803131065NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3605804131065NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3605805131065NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3605806131065NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3605807131065NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3605808131065NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3605809131065NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3605810131065NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3605811131065NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3605812131065NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3605813131065NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3605814131065NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3605815131065NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3605816131065NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3605817131065NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3605818131065NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3605819131065NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3605820131065NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3605821131065NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3605822131065NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3605823131065NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3605824131065NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3605825131065NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3605826131065NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3605827131065NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3605828131065NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3605829131065NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3605830131065NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3605831131065NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3605832131065NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3605833131065NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3605834131065NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3605835131065NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3605836131065NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3605837131065NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3605838131065NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3605839131065NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3605840131065NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3605841131065NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3605842131065NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3605843131065NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3605844131065NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3605845131065NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3605846131065NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3605847131065NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3605848131065NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3605849131065NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3605850131065NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3605851131065NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3605852131065NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3605853131065NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3605854131065NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3605855131065NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3605856131065NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3605857131065NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3605858131065NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3605859131065NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3605860131065NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3605861131065NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3605862131065NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3605863131065NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3605864131065NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3605865131065NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3605866131065NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3605867131065NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3605868131065NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3605869131065NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3605870131065NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3605871131065NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3605872131065NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3605873131065NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3605874131065NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3605875131065NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3605876131065NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3605877131065NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3605878131065NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3605879131065NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3605880131065NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3605881131065Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218103620000NoneNoneBuildingsConstruction of primary health centre at gouripura, in gangavathi taluka in koppala district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3605882131066NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3605883131066NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3605884131066NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3605885131066NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3605886131066NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3605887131066NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3605888131066NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3605889131066NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3605890131066NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3605891131066NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3605892131066NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3605893131066NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3605894131066NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3605895131066NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3605896131066NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3605897131066NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3605898131066NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3605899131066NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3605900131066NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3605901131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3605902131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3605903131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3605904131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3605905131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3605906131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3605907131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3605908131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3605909131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3605910131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3605911131066NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3605912131066NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3605913131066NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3605914131066NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3605915131066NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3605916131066NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3605917131066NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3605918131066NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3605919131066NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3605920131066NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3605921131066NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3605922131066NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3605923131066NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3605924131066NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3605925131066NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3605926131066NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3605927131066NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3605928131066NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3605929131066NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3605930131066NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3605931131066NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3605932131066NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3605933131066NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3605934131066NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3605935131066NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3605936131066NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3605937131066NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3605938131066NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3605939131066NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3605940131066NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3605941131066NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3605942131066NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3605943131066NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3605944131066NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3605945131066NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3605946131066NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3605947131066NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3605948131066NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3605949131066NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3605950131066NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3605951131066NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3605952131066NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3605953131066NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3605954131066NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3605955131066NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3605956131066NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3605957131066NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3605958131066NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3605959131066NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3605960131066NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3605961131066NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3605962131066NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3605963131066NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3605964131066NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3605965131066NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3605966131066NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3605967131066NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3605968131066NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3605969131066NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3605970131066NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3605971131066NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3605972131066NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3605973131066NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3605974131066NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3605975131066NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3605976131066NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3605977131066NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3605978131066NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3605979131066NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3605980131066NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3605981131066NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3605982131066NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3605983131066NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3605984131066NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3605985131066NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3605986131066NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3605987131066NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3605988131066NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3605989131066NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3605990131066NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3605991131066NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3605992131066NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3605993131066NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3605994131066NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3605995131066NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3605996131066NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3605997131066NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3605998131066NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3605999131066NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3606000131066NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3606001131066NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3606002131066NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3606003131066NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3606004131066NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3606005131066NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3606006131066NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3606007131066NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3606008131066NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3606009131066NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3606010131066NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3606011131066NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3606012131066NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3606013131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3606014131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3606015131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3606016131066NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3606017131066NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3606018131066NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3606019131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3606020131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3606021131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3606022131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3606023131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3606024131066NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3606025131066NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3606026131066NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3606027131066NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3606028131066NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3606029131066NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3606030131066NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3606031131066NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3606032131066NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3606033131066NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3606034131066NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3606035131066NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3606036131066NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3606037131066NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3606038131066NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3606039131066NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3606040131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3606041131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3606042131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3606043131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3606044131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3606045131066NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3606046131066NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3606047131066NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3606048131066NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3606049131066NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3606050131066NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3606051131066NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3606052131066NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3606053131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3606054131066NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3606055131066NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3606056131066NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3606057131066NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3606058131066NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3606059131066NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3606060131066NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3606061131066NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3606062131066NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3606063131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3606064131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3606065131066NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3606066131066NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3606067131066NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3606068131066NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3606069131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3606070131066NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3606071131066NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3606072131066NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3606073131066NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3606074131066NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3606075131066NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3606076131066NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3606077131066NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3606078131066NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3606079131066NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3606080131066NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3606081131066NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3606082131066NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3606083131066NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3606084131066NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3606085131066NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3606086131066NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3606087131066NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3606088131066NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3606089131066NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3606090131066NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3606091131066NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3606092131066NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3606093131066NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3606094131066NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3606095131066NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3606096131066NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3606097131066NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3606098131066NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3606099131066NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3606100131066NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3606101131066NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3606102131066NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3606103131066NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3606104131066NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3606105131066NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3606106131066NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3606107131066NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3606108131066NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3606109131066NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3606110131066NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3606111131066NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3606112131066NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3606113131066NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3606114131066NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3606115131066NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3606116131066NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3606117131066NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3606118131066NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3606119131066NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3606120131066NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3606121131066NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3606122131066NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3606123131066NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3606124131066NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3606125131066NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3606126131066NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3606127131066NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3606128131066NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3606129131066NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3606130131066NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3606131131066NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3606132131066NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3606133131066NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3606134131066NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3606135131066NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3606136131066NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3606137131066NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3606138131066NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3606139131066NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3606140131066NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3606141131066NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3606142131066NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3606143131066NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3606144131066NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3606145131066NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3606146131066NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3606147131066NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3606148131066NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3606149131066NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3606150131066NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3606151131066NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3606152131066NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3606153131066NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3606154131066NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3606155131066NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3606156131066NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3606157131066NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3606158131066NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3606159131066NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3606160131066NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3606161131066NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3606162131066NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3606163131066NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3606164131066NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3606165131066NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3606166131066NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3606167131066NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3606168131066NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3606169131066NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3606170131066NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3606171131066NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3606172131066NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3606173131066NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3606174131066NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3606175131066NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3606176131066NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3606177131066NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3606178131066NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3606179131066NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3606180131066NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3606181131066NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3606182131066NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3606183131066NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3606184131066NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3606185131066NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3606186131066NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3606187131066NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3606188131066NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3606189131066NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3606190131066NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3606191131066NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3606192131066NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3606193131066NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3606194131066NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3606195131066NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3606196131066NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3606197131066NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3606198131066NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3606199131066NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3606200131066NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3606201131066NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3606202131066NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3606203131066NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3606204131066NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3606205131066NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3606206131066NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3606207131066NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3606208131066NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3606209131066NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3606210131066NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3606211131066NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3606212131066NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3606213131066NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3606214131066NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3606215131066NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3606216131066NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3606217131066NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3606218131066NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3606219131066NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3606220131066NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3606221131066NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3606222131066NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3606223131066NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3606224131066NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3606225131066NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3606226131066NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3606227131066NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3606228131066NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3606229131066NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3606230131066NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3606231131066NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3606232131066NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3606233131066NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3606234131066NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3606235131066NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3606236131066NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3606237131066NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3606238131066NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3606239131066NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3606240131066NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3606241131066NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3606242131066NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3606243131066NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3606244131066NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3606245131066NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3606246131066NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3606247131066NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3606248131066NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3606249131066NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3606250131066NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3606251131066NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3606252131066NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3606253131066NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3606254131066NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3606255131066NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3606256131066NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3606257131066NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3606258131066NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3606259131066NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3606260131066NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3606261131066NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3606262131066NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3606263131066NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3606264131066NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3606265131066NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3606266131066NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3606267131066NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3606268131066NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3606269131066NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3606270131066NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3606271131066NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3606272131066NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3606273131066NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3606274131066NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3606275131066NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3606276131066NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3606277131066NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3606278131066NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3606279131066NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3606280131066NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3606281131066NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3606282131066NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3606283131066NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3606284131066NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3606285131066NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3606286131066NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3606287131066NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3606288131066NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3606289131066NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3606290131066NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3606291131066NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3606292131066NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3606293131066NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3606294131066NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3606295131066NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3606296131066NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3606297131066NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3606298131066NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3606299131066NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3606300131066NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3606301131066NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3606302131066NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3606303131066NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3606304131066NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3606305131066NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3606306131066NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3606307131066NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3606308131066NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3606309131066NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3606310131066NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3606311131066NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3606312131066NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3606313131066NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3606314131066NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3606315131066NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3606316131066NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3606317131066NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3606318131066NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3606319131066NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3606320131066NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3606321131066NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3606322131066NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3606323131066NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3606324131066NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3606325131066NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3606326131066NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3606327131066NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3606328131066NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3606329131066NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3606330131066NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3606331131066NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3606332131066NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3606333131066NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3606334131066NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3606335131066NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3606336131066NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3606337131066NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3606338131066NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3606339131066NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3606340131066NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3606341131066NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3606342131066NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3606343131066NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3606344131066NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3606345131066NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3606346131066NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3606347131066NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3606348131066NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3606349131066NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3606350131066NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3606351131066NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3606352131066NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3606353131066NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3606354131066NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3606355131066NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3606356131066NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3606357131066NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3606358131066NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3606359131066NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3606360131066NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3606361131066NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3606362131066NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3606363131066NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3606364131066NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3606365131066NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3606366131066NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3606367131066NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3606368131066NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3606369131066NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3606370131066NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3606371131066NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3606372131066NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3606373131066NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3606374131066NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3606375131066NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3606376131066NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3606377131066NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3606378131066NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3606379131066NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3606380131066NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3606381131066NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3606382131066NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3606383131066NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3606384131066NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3606385131066NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3606386131066NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3606387131066NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3606388131066NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3606389131066NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3606390131066NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3606391131066NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3606392131066NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3606393131066NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3606394131066NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3606395131066NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3606396131066NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3606397131066NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3606398131066NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3606399131066NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3606400131066NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3606401131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3606402131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3606403131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3606404131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3606405131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3606406131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3606407131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3606408131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3606409131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3606410131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3606411131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3606412131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3606413131066NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3606414131066NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3606415131066NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3606416131066NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3606417131066NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3606418131066NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3606419131066NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3606420131066NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3606421131066NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3606422131066NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3606423131066NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3606424131066NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3606425131066NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3606426131066NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3606427131066NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3606428131066NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3606429131066NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3606430131066NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3606431131066NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3606432131066NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3606433131066NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3606434131066NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3606435131066NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3606436131066NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3606437131066NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3606438131066NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3606439131066NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3606440131066NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3606441131066NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3606442131066NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3606443131066NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3606444131066NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3606445131066NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3606446131066NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3606447131066NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3606448131066NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3606449131066NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3606450131066NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3606451131066NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3606452131066NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3606453131066NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3606454131066NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3606455131066NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3606456131066NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3606457131066NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3606458131066NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3606459131066NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3606460131066NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3606461131066NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3606462131066NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3606463131066NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3606464131066NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3606465131066NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3606466131066NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3606467131066NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3606468131066NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3606469131066NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3606470131066NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3606471131066NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3606472131066NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3606473131066NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3606474131066NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3606475131066NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3606476131066NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3606477131066NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3606478131066NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3606479131066NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3606480131066NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3606481131066NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3606482131066NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3606483131066NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3606484131066NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3606485131066NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3606486131066NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3606487131066NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3606488131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3606489131066NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3606490131066NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3606491131066NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3606492131066NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3606493131066NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3606494131066NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3606495131066NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3606496131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3606497131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3606498131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3606499131066NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3606500131066NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3606501131066NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3606502131066NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3606503131066NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3606504131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3606505131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3606506131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3606507131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3606508131066NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3606509131066NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3606510131066NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3606511131066NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3606512131066NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3606513131066NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3606514131066NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3606515131066NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3606516131066NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3606517131066NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3606518131066NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3606519131066NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3606520131066NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3606521131066NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3606522131066NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3606523131066NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3606524131066NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3606525131066NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3606526131066NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3606527131066NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3606528131066NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3606529131066NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3606530131066NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3606531131066NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3606532131066NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3606533131066NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3606534131066NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3606535131066NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3606536131066NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3606537131066NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3606538131066NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3606539131066NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3606540131066NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3606541131066NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3606542131066NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3606543131066NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3606544131066NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3606545131066NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3606546131066NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3606547131066NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3606548131066NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3606549131066NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3606550131066NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3606551131066NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3606552131066NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3606553131066NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3606554131066NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3606555131066NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3606556131066NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3606557131066NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3606558131066NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3606559131066NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3606560131066NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3606561131066NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3606562131066NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3606563131066NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3606564131066NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3606565131066NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3606566131066NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3606567131066NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3606568131066NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3606569131066NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3606570131066NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3606571131066NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3606572131066NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3606573131066NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3606574131066NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3606575131066NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3606576131066NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3606577131066NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3606578131066NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3606579131066NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3606580131066NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3606581131066NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3606582131066NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3606583131066NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3606584131066NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3606585131066NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3606586131066NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3606587131066NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3606588131066NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3606589131066NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3606590131066NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3606591131066Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218103640000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218103640000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218103640000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17218103640000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218103640000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218103740000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17218103800000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17218103860000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17218103910000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17218103960000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17218104010000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17218104060000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17218104110000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17218104160000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17218104200000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17218104250000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17218104300000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17218104350000NoneNoneELIGIBILITYMaterials like, steel(primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17218104390000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17218104460000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17218104510000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17218104550000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17218104590000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17218104670000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17218104720000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.3739.10 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.1402.15 lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works 1. Earthwork Excavation in all kinds of soil 9798.00 Cum 2.PCC & RCC 4833.00 Cum 3. Steel Reinforcement for RCC work (TMT Steel) 310.91 Tonne 4.BBM/Concrete Blocks 2143.00 Cum. 5. Plastering 28213.00 Sqm 6. Painting (OBD/Textured Painting/Wood and Metal Painting) 43450.00 Sqm 7. Flooring (Vitrified/Granite/Ceramic) 6536.00 Sqm 8. MS Grill 9144.00 Kgs Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d The tenderer or his identified sub contractor should possess required valid electrical license issued by KPWD,Government electrical Inspectorate for executing building electrification works and should have executed similar Building electrical works totaling to Rs.223.94 Lakhs in any one year Note.The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government,Semi Government,Government undertaking,autonomous bodies of Government will be considered, for the clause 3.2d.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e):The Tenderer or his identified sub-contractor should possess valid license issued by BWSSB/KUWS&DB for executing water supply/sanitary engineering works and should have executed similar building water supply/sanitary engineering works totaling to Rs.50.71 Lakhs in any one year Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass - I PWD Registered Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.3(a) Equipment capacity: Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50%can be deployed on ease/hire basis for all works provided,the relevant documents (commitment agreements etc) for availability for this work are furnished Sl No. Description of Key items of Works. Quantity1. Excavator/JCB 2 Nos 2. Transit Mixer/Concrete Mixer 2 Nos 3. Needle vibrator with size not less than 20mm 2 Nos 4.Tipper 2 Nos 5.Generator 250 KVA 2 Nos 6. Truck Mounted Water Tanker 2 Nos Note: All Machineries purchased during last five years only should be used and will be considered for evaluation.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneClause ITT 3.6 Tenderers who meet the above specified minimum qualifying criteria,will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2019-20-2023-24)(updated to 2024-25 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2024-25 price level, of existing commitments of and ongoing works to be Completed during the next 18 months.Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1) Site Engineer (Civil) B.E. Civil with minimum experience of 7 years in the Construction of buildings 1 (One) 2) Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.560.86 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
ESI & PF CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721810874000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone