tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721809517000 | 0 | None | None | Buildings | Barur PHC(Civil Works) | 19709674.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3599882 | 131021 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle | 100 Sqm | 486.93 | 486.93 | 20.0 | False | None | None | False | None | False | 9738.6 | 0 | 3599883 | 131021 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.71 | 117.71 | 222.09 | False | None | None | False | None | False | 26142.2139 | 0 | 3599884 | 131021 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.38 | 126.38 | 670.52 | False | None | None | False | None | False | 84740.3176 | 0 | 3599885 | 131021 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.76 | 449.76 | 167.63 | False | None | None | False | None | False | 75393.2688 | 0 | 3599886 | 131021 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) | Cum | 167.27 | 167.27 | 100.0 | False | None | None | False | None | False | 16727.0 | 0 | 3599887 | 131021 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 570.14 | False | None | None | False | None | False | 83354.468 | 0 | 3599888 | 131021 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 670.52 | False | None | None | False | None | False | 220983.2764 | 0 | 3599889 | 131021 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.29 | 587.29 | 143.97 | False | None | None | False | None | False | 84552.1413 | 0 | 3599890 | 131021 | None | V-1page 15 itm2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 123.48 | False | None | None | False | None | False | 916267.2876 | 0 | 3599891 | 131021 | None | V-1page15 itm 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Formwork, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates | Cum | 8412.76 | 8412.76 | 94.25 | False | None | None | False | None | False | 792902.63 | 0 | 3599892 | 131021 | None | V-1page16 itm 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 14413.41 | 14413.41 | 37.06 | False | None | None | False | None | False | 534160.9746 | 0 | 3599893 | 131021 | None | V-1page15itm 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7702.86 | 7702.86 | 6.96 | False | None | None | False | None | False | 53611.9056 | 0 | 3599894 | 131021 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy | No | 252.76 | 252.76 | 30.0 | False | None | None | False | None | False | 7582.8 | 0 | 3599895 | 131021 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3599896 | 131021 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings | Tonne | 110837.22 | 110837.22 | 37.25 | False | None | None | False | None | False | 4128686.445 | 0 | 3599897 | 131021 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS | Rmtr | 38.94 | 38.94 | 111.0 | False | None | None | False | None | False | 4322.34 | 0 | 3599898 | 131021 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. | Rmtr | 86.14 | 86.14 | 111.0 | False | None | None | False | None | False | 9561.54 | 0 | 3599899 | 131021 | None | V-2PAGE 9 ITM5.3 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7688.0 | 7688.0 | 17.19 | False | None | None | False | None | False | 132156.72 | 0 | 3599900 | 131021 | None | V-2PAGE 14 ITM 6.32 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9873.59 | 9873.59 | 199.58 | False | None | None | False | None | False | 1970571.0922 | 0 | 3599901 | 131021 | None | V-2page 14 itm 6.13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 1209.26 | 1209.26 | 86.23 | False | None | None | False | None | False | 104274.4898 | 0 | 3599902 | 131021 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.79 | 122431.79 | 0.99 | False | None | None | False | None | False | 121207.4721 | 0 | 3599903 | 131021 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 14.0 | False | None | None | False | None | False | 17623.48 | 0 | 3599904 | 131021 | None | V-2page 104 itm 12.51 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1314.58 | 1314.58 | 14.0 | False | None | None | False | None | False | 18404.12 | 0 | 3599905 | 131021 | None | V-2 page 105 itm 12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 1226.61 | 1226.61 | 14.0 | False | None | None | False | None | False | 17172.54 | 0 | 3599906 | 131021 | None | V-2page 105 itm 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with
necessary screws etc. complete | Nos | 293.64 | 293.64 | 28.0 | False | None | None | False | None | False | 8221.92 | 0 | 3599907 | 131021 | None | V-2page 105itm 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 28.0 | False | None | None | False | None | False | 4509.96 | 0 | 3599908 | 131021 | None | V-2page105 itm 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.15 | 68.15 | 14.0 | False | None | None | False | None | False | 954.1 | 0 | 3599909 | 131021 | None | V-2page107itm12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Nos | 340.73 | 340.73 | 28.0 | False | None | None | False | None | False | 9540.44 | 0 | 3599910 | 131021 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | Nos | 74.34 | 74.34 | 84.0 | False | None | None | False | None | False | 6244.56 | 0 | 3599911 | 131021 | None | XI page 18-19 SR313 (0115) | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Rmtr | 15.0 | 15.0 | 105.8 | False | None | None | False | None | False | 1587.0 | 0 | 3599912 | 131021 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.96 | 4115.96 | 41.21 | False | None | None | False | None | False | 169618.7116 | 0 | 3599913 | 131021 | None | V-2page109 itm 12.87 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 8116.69 | 8116.69 | 77.31 | False | None | None | False | None | False | 627501.3039 | 0 | 3599914 | 131021 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7085.84 | 7085.84 | 6.48 | False | None | None | False | None | False | 45916.2432 | 0 | 3599915 | 131021 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 208.15 | 208.15 | 2159.01 | False | None | None | False | None | False | 449397.9315 | 0 | 3599916 | 131021 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3599917 | 131021 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 168.5 | 168.5 | 120.96 | False | None | None | False | None | False | 20381.76 | 0 | 3599918 | 131021 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) | Sqm | 386.57 | 386.57 | 1049.85 | False | None | None | False | None | False | 405840.5145 | 0 | 3599919 | 131021 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 261.43 | 261.43 | 531.95 | False | None | None | False | None | False | 139067.6885 | 0 | 3599920 | 131021 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 123.9 | 123.9 | 1581.8 | False | None | None | False | None | False | 195985.02 | 0 | 3599921 | 131021 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) | Sqm | 432.41 | 432.41 | 1016.08 | False | None | None | False | None | False | 439363.1528 | 0 | 3599922 | 131021 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 438.61 | 438.61 | 29.15 | False | None | None | False | None | False | 12785.4815 | 0 | 3599923 | 131021 | None | 118page18-19 SR15.36 | Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | Rmtr | 36.58 | 36.58 | 800.0 | False | None | None | False | None | False | 29264.0 | 0 | 3599924 | 131021 | None | 18-19 SR0.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. | Sqm | 254.88 | 254.88 | 20.0 | False | None | None | False | None | False | 5097.6 | 0 | 3599925 | 131021 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | Rmtr | 64.43 | 64.43 | 709.5 | False | None | None | False | None | False | 45713.085 | 0 | 3599926 | 131021 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm | Sqm | 1455.83 | 1455.83 | 293.21 | False | None | None | False | None | False | 426863.9143 | 0 | 3599927 | 131021 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3599928 | 131021 | None | V-2page63 itm 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent. | Sqm | 3055.37 | 3055.37 | 214.93 | False | None | None | False | None | False | 656690.6741 | 0 | 3599929 | 131021 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 365.51 | 365.51 | 891.34 | False | None | None | False | None | False | 325793.6834 | 0 | 3599930 | 131021 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 1101.47 | 1101.47 | 29.98 | False | None | None | False | None | False | 33022.0706 | 0 | 3599931 | 131021 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1795.31 | 1795.31 | 891.34 | False | None | None | False | None | False | 1600231.6154 | 0 | 3599932 | 131021 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 700.04 | 700.04 | 260.78 | False | None | None | False | None | False | 182556.4312 | 0 | 3599933 | 131021 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 157.35 | 157.35 | 1581.8 | False | None | None | False | None | False | 248896.23 | 0 | 3599934 | 131021 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 762.06 | False | None | None | False | None | False | 147290.9568 | 0 | 3599935 | 131021 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 61.95 | 61.95 | 83.79 | False | None | None | False | None | False | 5190.7905 | 0 | 3599936 | 131021 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 142.49 | 142.49 | 83.79 | False | None | None | False | None | False | 11939.2371 | 0 | 3599937 | 131021 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.67 | 65.67 | 98.89 | False | None | None | False | None | False | 6494.1063 | 0 | 3599938 | 131021 | None | V-2page49itm 8.47 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.27 | 167.27 | 98.89 | False | None | None | False | None | False | 16541.3303 | 0 | 3599939 | 131021 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3599940 | 131021 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 5548.24 | 5548.24 | 3.15 | False | None | None | False | None | False | 17476.956 | 0 | 3599941 | 131021 | None | LQR | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.
System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification.
Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.
| Sqm | 1593.0 | 1593.0 | 633.5 | False | None | None | False | None | False | 1009165.5 | 0 | 3599942 | 131021 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications | Sqm | 411.35 | 411.35 | 16.34 | False | None | None | False | None | False | 6721.459 | 0 | 3599943 | 131021 | None | V-2PAGE27ITM 7.40 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. | Sqm | 2118.69 | 2118.69 | 48.84 | False | None | None | False | None | False | 103476.8196 | 0 | 3599944 | 131021 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9326.32 | 9326.32 | 20.24 | False | None | None | False | None | False | 188764.7168 | 0 | 3599945 | 131021 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 44.58 | False | None | None | False | None | False | 566955.9576 | 0 | 3599946 | 131021 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 13565.56 | 13565.56 | 30.15 | False | None | None | False | None | False | 409001.634 | 0 | 3599947 | 131021 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 87.68 | False | None | None | False | None | False | 1115089.6896 | 0 | 3599948 | 131021 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 4.32 | False | None | None | False | None | False | 54940.5504 | 0 | 3599949 | 131021 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 13.25 | False | None | None | False | None | False | 168509.79 | 0 | 3599950 | 131021 | None | ITEM 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops | Sqm | 350.64 | 350.64 | 254.02 | False | None | None | False | None | False | 89069.5728 | 0 | 3599951 | 131021 | None | 12.94.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(Internal WS AND SANITARY) | 1166957.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3599952 | 131022 | None | V-2 P.NO 135 IT.NO 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
40mm dia pipes, From wash basin waste lines
| Rmtr | 113.99 | 113.99 | 40.0 | False | None | None | False | None | False | 4559.6 | 0 | 3599953 | 131022 | None | V-5 P.NO 187 IT.NO T090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
50mm nominal bore pipes, From Sink & Urinal lines
| Rmtr | 213.38 | 213.38 | 20.0 | False | None | None | False | None | False | 4267.6 | 0 | 3599954 | 131022 | None | V-5 P.NO 34 IT.NO 3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines
| Rmtr | 337.73 | 337.73 | 50.0 | False | None | None | False | None | False | 16886.5 | 0 | 3599955 | 131022 | None | V-5 P.NO 34 IT.NO 3713 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines
| Rmtr | 630.94 | 630.94 | 180.0 | False | None | None | False | None | False | 113569.2 | 0 | 3599956 | 131022 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
| Rmtr | 244.08 | 244.08 | 25.0 | False | None | None | False | None | False | 6102.0 | 0 | 3599957 | 131022 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
| Rmtr | 360.55 | 360.55 | 60.0 | False | None | None | False | None | False | 21633.0 | 0 | 3599958 | 131022 | None | V-2 P.NO 128 IT.NO 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| No | 1511.58 | 1511.58 | 20.0 | False | None | None | False | None | False | 30231.6 | 0 | 3599959 | 131022 | None | V-2 P.NO 116 IT.NO 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
| No | 345.68 | 345.68 | 3.0 | False | None | None | False | None | False | 1037.04 | 0 | 3599960 | 131022 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
| No | 6891.32 | 6891.32 | 3.0 | False | None | None | False | None | False | 20673.96 | 0 | 3599961 | 131022 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| No | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3599962 | 131022 | None | V-2 P.NO 123 IT.NO 14.3 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and
mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good
the walls and floors wherever required
| No | 7192.4 | 7192.4 | 8.0 | False | None | None | False | None | False | 57539.2 | 0 | 3599963 | 131022 | None | V-2 P.NO 178 IT.NO 20.44.2 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm
| No | 4394.73 | 4394.73 | 10.0 | False | None | None | False | None | False | 43947.3 | 0 | 3599964 | 131022 | None | V-2 P.NO 124 IT.NO14.4.4 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern
| No | 16193.73 | 16193.73 | 4.0 | False | None | None | False | None | False | 64774.92 | 0 | 3599965 | 131022 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
| No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3599966 | 131022 | None | V-2 P.NO 126 IT.NO 14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm
| No | 5986.85 | 5986.85 | 2.0 | False | None | None | False | None | False | 11973.7 | 0 | 3599967 | 131022 | None | V-2 P.NO A-14 IT.NO 91 | C.P. Brass stop cock (concealed) 15 mm
| No | 650.48 | 650.48 | 10.0 | False | None | None | False | None | False | 6504.8 | 0 | 3599968 | 131022 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
| No | 3818.6 | 3818.6 | 5.0 | False | None | None | False | None | False | 19093.0 | 0 | 3599969 | 131022 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia | Rmtr | 382.85 | 382.85 | 60.0 | False | None | None | False | None | False | 22971.0 | 0 | 3599970 | 131022 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia | Rmtr | 469.58 | 469.58 | 50.0 | False | None | None | False | None | False | 23479.0 | 0 | 3599971 | 131022 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
| Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3599972 | 131022 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
| Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3599973 | 131022 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
| Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3599974 | 131022 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
| Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3599975 | 131022 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
| Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3599976 | 131022 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
| Rmtr | 893.32 | 893.32 | 25.0 | False | None | None | False | None | False | 22333.0 | 0 | 3599977 | 131022 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
| Rmtr | 591.0 | 591.0 | 150.0 | False | None | None | False | None | False | 88650.0 | 0 | 3599978 | 131022 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
| Rmtr | 1734.6 | 1734.6 | 23.0 | False | None | None | False | None | False | 39895.8 | 0 | 3599979 | 131022 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
| Rmtr | 893.32 | 893.32 | 25.0 | False | None | None | False | None | False | 22333.0 | 0 | 3599980 | 131022 | None | CPWD SR, V-2,P.NO 109,IT.NO 1927 | Brass full way valve with C.I. wheel (screwed end) 25 mm dia
| Each | 442.5 | 442.5 | 10.0 | False | None | None | False | None | False | 4425.0 | 0 | 3599981 | 131022 | None | CPWD SR, V-2, P.NO 110,IT.NO 1928 | Brass full way valve with C.I. wheel (screwed end) 32 mm dia
| Each | 489.7 | 489.7 | 5.0 | False | None | None | False | None | False | 2448.5 | 0 | 3599982 | 131022 | None | CPWD SR, V-2, P.NO 111,IT.NO 1929 | Brass full way valve with C.I. wheel (screwed end) 40 mm dia
| Each | 590.0 | 590.0 | 5.0 | False | None | None | False | None | False | 2950.0 | 0 | 3599983 | 131022 | None | CPWD SR, V-2,P.NO 112,IT.NO 1930 | Brass full way valve with C.I. wheel (screwed end) 50 mm dia
| Each | 737.5 | 737.5 | 2.0 | False | None | None | False | None | False | 1475.0 | 0 | 3599984 | 131022 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
| No | 354.35 | 354.35 | 15.0 | False | None | None | False | None | False | 5315.25 | 0 | 3599985 | 131022 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
| No | 11.15 | 11.15 | 2000.0 | False | None | None | False | None | False | 22300.0 | 0 | 3599986 | 131022 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.
100 Liter capacity
| No | 37498.04 | 37498.04 | 2.0 | False | None | None | False | None | False | 74996.08 | 0 | 3599987 | 131022 | None | Market Rate | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards
Ground Toilet
10Cms X 7.5Cms
| No | 371.7 | 371.7 | 45.0 | False | None | None | False | None | False | 16726.5 | 0 | 3599988 | 131022 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
| No | 177.0 | 177.0 | 45.0 | False | None | None | False | None | False | 7965.0 | 0 | 3599989 | 131022 | None | Market Rate | Air Vent Cowel
75mm
| No | 413.0 | 413.0 | 20.0 | False | None | None | False | None | False | 8260.0 | 0 | 3599990 | 131022 | None | Market Rate | Air Vent Cowel
110mm
| No | 590.0 | 590.0 | 20.0 | False | None | None | False | None | False | 11800.0 | 0 | 3599991 | 131022 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. brass pillar taps with C.I. /M.S. brackets, 32 mm C.P. brass waste of standard pattern, including Brass stop cock, 32mm PVC connection painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification as directed by the Engineer in charge. CNS-WHT-705, make Jaguar/hindware/Cera
| No | 5664.0 | 5664.0 | 20.0 | False | None | None | False | None | False | 113280.0 | 0 | 3599992 | 131022 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
| No | 2183.0 | 2183.0 | 8.0 | False | None | None | False | None | False | 17464.0 | 0 | 3599993 | 131022 | None | Market Rate | Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent )
| No | 1996.56 | 1996.56 | 4.0 | False | None | None | False | None | False | 7986.24 | 0 | 3599994 | 131022 | None | Market Rate | Providing and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. | No | 1147.9 | 1147.9 | 10.0 | False | None | None | False | None | False | 11479.0 | 0 | 3599995 | 131022 | None | Market Rate | Providing and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot.
-do- 10cms x 7.5 cms
| Each | 295.0 | 295.0 | 10.0 | False | None | None | False | None | False | 2950.0 | 0 | 3599996 | 131022 | None | Market Rate | Supplying, fixing, testing and commissioning of single sink with large basin for Hospital use.
Pedal-controlled faucet and button-controlled soap dispenser.
The basin is supplied complete with drain, siphon, flexible connection to the water mains and plugs for wall mounting. | No | 25370.0 | 25370.0 | 1.0 | False | None | None | False | None | False | 25370.0 | 0 | 3599997 | 131022 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
| No | 767.0 | 767.0 | 65.0 | False | None | None | False | None | False | 49855.0 | 0 | 3599998 | 131022 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
| No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3599999 | 131022 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
| No | 3304.0 | 3304.0 | 2.0 | False | None | None | False | None | False | 6608.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(EXTERNAL WS & SANITARY) | 1181322.64 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600000 | 131023 | None | V-1,P.NO 6,IT.NO 1.5 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage
& other appurtenances required to complete the work. | Cum | 370.46 | 370.46 | 278.0 | False | None | None | False | None | False | 102987.88 | 0 | 3600001 | 131023 | None | V-1 P.NO 7 IT.NO 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 329.57 | 329.57 | 278.0 | False | None | None | False | None | False | 91620.46 | 0 | 3600002 | 131023 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
- do - 160 mm dia
| Rmtr | 713.66 | 713.66 | 350.0 | False | None | None | False | None | False | 249781.0 | 0 | 3600003 | 131023 | None | V-5,P.NO 134,IT.NO- 10.2.5 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
- do - 200 mm dia
| Rmtr | 1029.61 | 1029.61 | 60.0 | False | None | None | False | None | False | 61776.6 | 0 | 3600004 | 131023 | None | V-5 P.NO 134 IT.NO 10.2.6 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
- do - 250 mm dia
| Rmtr | 1578.49 | 1578.49 | 10.0 | False | None | None | False | None | False | 15784.9 | 0 | 3600005 | 131023 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
| Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3600006 | 131023 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
| No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3600007 | 131023 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
| No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3600008 | 131023 | None | MARKET RATE | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms
| No | 330.4 | 330.4 | 25.0 | False | None | None | False | None | False | 8260.0 | 0 | 3600009 | 131023 | None | IT.NO 11.39 | KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22 m internal dia at bottom, 1.68 m deep and 0.56m dia at top, with table moulded and non modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and down size granite metal and making necessary channel in cement concrete M 15 with 20mm and down size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, total weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
| No | 36325.0 | 36325.0 | 1.0 | False | None | None | False | None | False | 36325.0 | 0 | 3600010 | 131023 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
| Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3600011 | 131023 | None | Market Rate | Supply and fixing of GM ball cock with copper float(High pressure float)of ISI or BIS Standardsand & fixed on to the inlet pipe at the underground sump tank & OHT.
| No | 5900.0 | 5900.0 | 5.0 | False | None | None | False | None | False | 29500.0 | 0 | 3600012 | 131023 | None | CSR | PUMPS
Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (DOMESTIC)2.00 HP
| Each | 41300.0 | 41300.0 | 2.0 | False | None | None | False | None | False | 82600.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(INETRNAL ELECTRICAL) | 1238058.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600013 | 131024 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
| Point | 333.29 | 333.29 | 36.0 | False | None | None | False | None | False | 11998.44 | 0 | 3600014 | 131024 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
| Pack | 469.58 | 469.58 | 45.0 | False | None | None | False | None | False | 21131.1 | 0 | 3600015 | 131024 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
| Point | 687.65 | 687.65 | 60.0 | False | None | None | False | None | False | 41259.0 | 0 | 3600016 | 131024 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 838.8 | 838.8 | 4.0 | False | None | None | False | None | False | 3355.2 | 0 | 3600017 | 131024 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
| Each | 170.89 | 170.89 | 20.0 | False | None | None | False | None | False | 3417.8 | 0 | 3600018 | 131024 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
| Each | 197.0 | 197.0 | 10.0 | False | None | None | False | None | False | 1970.0 | 0 | 3600019 | 131024 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
| Each | 219.3 | 219.3 | 10.0 | False | None | None | False | None | False | 2193.0 | 0 | 3600020 | 131024 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
| Each | 272.58 | 272.58 | 22.0 | False | None | None | False | None | False | 5996.76 | 0 | 3600021 | 131024 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
| Each | 323.38 | 323.38 | 25.0 | False | None | None | False | None | False | 8084.5 | 0 | 3600022 | 131024 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
| Each | 199.48 | 199.48 | 20.0 | False | None | None | False | None | False | 3989.6 | 0 | 3600023 | 131024 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
| Each | 216.83 | 216.83 | 10.0 | False | None | None | False | None | False | 2168.3 | 0 | 3600024 | 131024 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
| Each | 289.93 | 289.93 | 10.0 | False | None | None | False | None | False | 2899.3 | 0 | 3600025 | 131024 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
| Each | 351.88 | 351.88 | 22.0 | False | None | None | False | None | False | 7741.36 | 0 | 3600026 | 131024 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
| Each | 426.22 | 426.22 | 25.0 | False | None | None | False | None | False | 10655.5 | 0 | 3600027 | 131024 | None | PWD ELE SR V-27 IT.NO 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
| Each | 126.38 | 126.38 | 216.0 | False | None | None | False | None | False | 27298.08 | 0 | 3600028 | 131024 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
| Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3600029 | 131024 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
| Each | 211.87 | 211.87 | 72.0 | False | None | None | False | None | False | 15254.64 | 0 | 3600030 | 131024 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
| Each | 442.32 | 442.32 | 20.0 | False | None | None | False | None | False | 8846.4 | 0 | 3600031 | 131024 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
| Each | 223.02 | 223.02 | 7.0 | False | None | None | False | None | False | 1561.14 | 0 | 3600032 | 131024 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
| Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3600033 | 131024 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
| Each | 292.4 | 292.4 | 22.0 | False | None | None | False | None | False | 6432.8 | 0 | 3600034 | 131024 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
| No | 144.96 | 144.96 | 20.0 | False | None | None | False | None | False | 2899.2 | 0 | 3600035 | 131024 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
| Rmtr | 81.77 | 81.77 | 450.0 | False | None | None | False | None | False | 36796.5 | 0 | 3600036 | 131024 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
| Rmtr | 96.64 | 96.64 | 650.0 | False | None | None | False | None | False | 62816.0 | 0 | 3600037 | 131024 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
| Rmtr | 127.62 | 127.62 | 80.0 | False | None | None | False | None | False | 10209.6 | 0 | 3600038 | 131024 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
| Rmtr | 84.25 | 84.25 | 180.0 | False | None | None | False | None | False | 15165.0 | 0 | 3600039 | 131024 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
| Rmtr | 97.88 | 97.88 | 260.0 | False | None | None | False | None | False | 25448.8 | 0 | 3600040 | 131024 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
| Rmtr | 122.66 | 122.66 | 32.0 | False | None | None | False | None | False | 3925.12 | 0 | 3600041 | 131024 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
| Rmtr | 32.21 | 32.21 | 300.0 | False | None | None | False | None | False | 9663.0 | 0 | 3600042 | 131024 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
| Rmtr | 52.04 | 52.04 | 940.0 | False | None | None | False | None | False | 48917.6 | 0 | 3600043 | 131024 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
| Rmtr | 78.06 | 78.06 | 400.0 | False | None | None | False | None | False | 31224.0 | 0 | 3600044 | 131024 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
| Rmtr | 113.99 | 113.99 | 280.0 | False | None | None | False | None | False | 31917.2 | 0 | 3600045 | 131024 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
| Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3600046 | 131024 | None | PWD ELE SR V-6,IT.NO 5.19.4 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
I- Single Door
12 Way SP & N
| Each | 2308.26 | 2308.26 | 1.0 | False | None | None | False | None | False | 2308.26 | 0 | 3600047 | 131024 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
| Each | 514.19 | 514.19 | 34.0 | False | None | None | False | None | False | 17482.46 | 0 | 3600048 | 131024 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
| Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3600049 | 131024 | None | PWD ELE SR V-6,IT.NO 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps DP
| Each | 915.62 | 915.62 | 1.0 | False | None | None | False | None | False | 915.62 | 0 | 3600050 | 131024 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
| Each | 6538.2 | 6538.2 | 6.0 | False | None | None | False | None | False | 39229.2 | 0 | 3600051 | 131024 | None | PWD ELE SR V-6,IT.NO5.20.2 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
32 -40 Amps 2 pole
| Each | 5648.6 | 5648.6 | 1.0 | False | None | None | False | None | False | 5648.6 | 0 | 3600052 | 131024 | None | PWD ELE SR V-6 BSR-32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
3.5 core 35 sqmm
| Km | 258542.13 | 258542.13 | 0.2 | False | None | None | False | None | False | 51708.426 | 0 | 3600053 | 131024 | None | PWD ELE SR V-6,IT.NO BSR-31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
35 sqmm to 95 sqmm
| Km | 29298.63 | 29298.63 | 0.2 | False | None | None | False | None | False | 5859.726 | 0 | 3600054 | 131024 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
| Each | 144.96 | 144.96 | 8.0 | False | None | None | False | None | False | 1159.68 | 0 | 3600055 | 131024 | None | PWD ELE SR V-6,IT.NO 6.9.2 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.
50mm
| Rmtr | 470.82 | 470.82 | 10.0 | False | None | None | False | None | False | 4708.2 | 0 | 3600056 | 131024 | None | SR 19-20 IT.NO 6.6.2 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)
In soil (hard)
| Rmtr | 126.38 | 126.38 | 90.0 | False | None | None | False | None | False | 11374.2 | 0 | 3600057 | 131024 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
| Each | 39.65 | 39.65 | 8.0 | False | None | None | False | None | False | 317.2 | 0 | 3600058 | 131024 | None | PWD ELE SR V-6,IT.NO 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990.
3CX2.5 Sq mm
| Rmtr | 140.01 | 140.01 | 50.0 | False | None | None | False | None | False | 7000.5 | 0 | 3600059 | 131024 | None | PWD ELE SR V-6 IT.NO2.6.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990.
3CX4 Sq mm
| Rmtr | 206.91 | 206.91 | 100.0 | False | None | None | False | None | False | 20691.0 | 0 | 3600060 | 131024 | None | SR 19-20 IT.NO 6.1 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.
| No | 3716.63 | 3716.63 | 4.0 | False | None | None | False | None | False | 14866.52 | 0 | 3600061 | 131024 | None | SR 19-20 IT.NO 6.3.1 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
| Rmtr | 92.93 | 92.93 | 30.0 | False | None | None | False | None | False | 2787.9 | 0 | 3600062 | 131024 | None | PWD ELE SR V-6,IT.NO 6.3.4 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
50x6mm GI strip
| Rmtr | 241.61 | 241.61 | 20.0 | False | None | None | False | None | False | 4832.2 | 0 | 3600063 | 131024 | None | PWD ELE SR V-6,IT.NO 11.3.2 | Supplying of .feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fighting 1 x4'- 20/22 w | Each | 854.91 | 854.91 | 70.0 | False | None | None | False | None | False | 59843.7 | 0 | 3600064 | 131024 | None | PWD ELE SR V-6,IT.NO 11.6.2 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED modular down light 2'x2' / 1' x 4' 34 -36watt | No | 7307.62 | 7307.62 | 12.0 | False | None | None | False | None | False | 87691.44 | 0 | 3600065 | 131024 | None | PWD ELE SR V-6,IT.NO 11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
7 W, 6500K | No | 184.61 | 184.61 | 8.0 | False | None | None | False | None | False | 1476.88 | 0 | 3600066 | 131024 | None | PWD ELE SR V-6,IT.NO 11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
12 W, 6500K
| No | 333.29 | 333.29 | 13.0 | False | None | None | False | None | False | 4332.77 | 0 | 3600067 | 131024 | None | PWD ELE SR V-6,IT.NO 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply
| No | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3600068 | 131024 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
| Each | 1848.59 | 1848.59 | 10.0 | False | None | None | False | None | False | 18485.9 | 0 | 3600069 | 131024 | None | PWD ELE SR V-6,IT.NO 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.
48" Sweep (1200mm) Regular model
| Each | 3697.18 | 3697.18 | 20.0 | False | None | None | False | None | False | 73943.6 | 0 | 3600070 | 131024 | None | PWD ELE SR V-6,IT.NO 6.5.1 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.
300mm Sweep
| Each | 3087.59 | 3087.59 | 3.0 | False | None | None | False | None | False | 9262.77 | 0 | 3600071 | 131024 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
| Each | 151.16 | 151.16 | 81.0 | False | None | None | False | None | False | 12243.96 | 0 | 3600072 | 131024 | None | PWD ELE SR V-6,IT.NO 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 211.87 | 211.87 | 23.0 | False | None | None | False | None | False | 4873.01 | 0 | 3600073 | 131024 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
| Each | 875.97 | 875.97 | 10.0 | False | None | None | False | None | False | 8759.7 | 0 | 3600074 | 131024 | None | PWD ELE SR V-6,IT.NO 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.
LED Streetlight 25watts | No | 3004.58 | 3004.58 | 4.0 | False | None | None | False | None | False | 12018.32 | 0 | 3600075 | 131024 | None | PWD ELE SR V-6,IT.NO 13.2.2 | Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.
Using 32mm dia G.I.Pipe
| Each | 1604.51 | 1604.51 | 4.0 | False | None | None | False | None | False | 6418.04 | 0 | 3600076 | 131024 | None | PWD ELE SR V-6,IT.NO 13.5 | Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
| Each | 200.72 | 200.72 | 4.0 | False | None | None | False | None | False | 802.88 | 0 | 3600077 | 131024 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
| Sq CM | 0.53 | 0.53 | 110000.0 | False | None | None | False | None | False | 58300.0 | 0 | 3600078 | 131024 | None | PWD ELE SR V-6,IT.NO 5.40.1 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.
100Amps 4x30x6mm Aluminum Strips
| Rmtr | 3054.14 | 3054.14 | 4.0 | False | None | None | False | None | False | 12216.56 | 0 | 3600079 | 131024 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
| Rmtr | 377.9 | 377.9 | 8.0 | False | None | None | False | None | False | 3023.2 | 0 | 3600080 | 131024 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
| Rmtr | 936.68 | 936.68 | 8.0 | False | None | None | False | None | False | 7493.44 | 0 | 3600081 | 131024 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
| Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3600082 | 131024 | None | PWD ELE SR V-6,IT.NO 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
40Amps TPN
| Each | 3771.52 | 3771.52 | 3.0 | False | None | None | False | None | False | 11314.56 | 0 | 3600083 | 131024 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
| Each | 3826.03 | 3826.03 | 3.0 | False | None | None | False | None | False | 11478.09 | 0 | 3600084 | 131024 | None | PWD ELE SR V-6,IT.NO 5.11.2 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply.
100Amps
| Each | 8784.51 | 8784.51 | 1.0 | False | None | None | False | None | False | 8784.51 | 0 | 3600085 | 131024 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
| Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3600086 | 131024 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
| Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3600087 | 131024 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
| Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3600088 | 131024 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
| Kvar | 594.72 | 594.72 | 10.0 | False | None | None | False | None | False | 5947.2 | 0 | 3600089 | 131024 | None | PWD ELE SR V-6,IT.NO 5.44.1 | Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility.
300mmx300mmx214mm | Each | 5590.37 | 5590.37 | 1.0 | False | None | None | False | None | False | 5590.37 | 0 | 3600090 | 131024 | None | PWD ELE SR V-6,IT.NO 5.35 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.
| Each | 7068.5 | 7068.5 | 1.0 | False | None | None | False | None | False | 7068.5 | 0 | 3600091 | 131024 | None | PWD ELE SR V-6,IT.NO 3.6.12 | TELEPHONE & NETWORKING
RJ45/ I.O. outlet
| Each | 417.54 | 417.54 | 11.0 | False | None | None | False | None | False | 4592.94 | 0 | 3600092 | 131024 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Telephone socket
| Each | 193.28 | 193.28 | 8.0 | False | None | None | False | None | False | 1546.24 | 0 | 3600093 | 131024 | None | PWD ELE SR V-6,IT.NO 8.1 | Supplying and drawing UTP-CAT 6E LAN cable.
| Rmtr | 47.08 | 47.08 | 300.0 | False | None | None | False | None | False | 14124.0 | 0 | 3600094 | 131024 | None | PWD ELE SR V-6,IT.NO 8.10.1 | Supplying & Fixing of I/O Socket with back box Single I/O
| Each | 607.11 | 607.11 | 11.0 | False | None | None | False | None | False | 6678.21 | 0 | 3600095 | 131024 | None | PWD ELE SR V-6,IT.NO 8.4.1 | Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification
4U with 450mm depth
| Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3600096 | 131024 | None | PWD ELE SR V-6,IT.NO 8.9.11 | Supplying fixing of Network Switches.
16 port 10/100/1000 Switch
| Each | 7979.16 | 7979.16 | 1.0 | False | None | None | False | None | False | 7979.16 | 0 | 3600097 | 131024 | None | PWD ELE SR V-6,IT.NO 8.11.1 | Supplying & fixing of .mtrs. Cat 6Patch Cable. 2Mtr
| Each | 318.42 | 318.42 | 11.0 | False | None | None | False | None | False | 3502.62 | 0 | 3600098 | 131024 | None | PWD ELE SR V-6,IT.NO 8.12.3 | Supplying & Fixing of Patch panel for Lan Cabling.
16 Port 10/100 patch panel
| Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3600099 | 131024 | None | PWD ELE SR V-6,IT.NO 8.2.2 | Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable.
| Rmtr | 26.02 | 26.02 | 300.0 | False | None | None | False | None | False | 7806.0 | 0 | 3600100 | 131024 | None | PWD ELE SR V-6,IT.NO 8.13.1 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.
10 Pair
| Each | 427.46 | 427.46 | 1.0 | False | None | None | False | None | False | 427.46 | 0 | 3600101 | 131024 | None | MARKET RATE | TELEPHONES Analog push button telephone with Caller ID, flash and radiaL | No | 1858.5 | 1858.5 | 8.0 | False | None | None | False | None | False | 14868.0 | 0 | 3600102 | 131024 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
| Rmtr | 96.64 | 96.64 | 300.0 | False | None | None | False | None | False | 28992.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(EXTERNAL ELECTRICAL& DG SET) | 1241018.82 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600103 | 131025 | None | BSR- CDS-15 | Supply and fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles)
| Set | 31573.44 | 31573.44 | 1.0 | False | None | None | False | None | False | 31573.44 | 0 | 3600104 | 131025 | None | BSR- CDS-15 | Supply of 11 kV, 45 KN Polymeric Insulator
| No | 250.28 | 250.28 | 6.0 | False | None | None | False | None | False | 1501.68 | 0 | 3600105 | 131025 | None | BSR- CDS-15 | Supply and fixing of Guy Set Complete with No. 15 Strain Insulator & Concreting materials
| Set | 2053.02 | 2053.02 | 2.0 | False | None | None | False | None | False | 4106.04 | 0 | 3600106 | 131025 | None | BSR- CDS-15 | Supply and fixing of Spiral Earth Electrode
| No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 3600107 | 131025 | None | BSR- CDS-15 | Fixing of Guy concreting with Boulders, Mud and Sand
| No | 247.8 | 247.8 | 2.0 | False | None | None | False | None | False | 495.6 | 0 | 3600108 | 131025 | None | BSR- CDS-15 | Supply and fixing of Caution/Danger Board
| No | 256.47 | 256.47 | 1.0 | False | None | None | False | None | False | 256.47 | 0 | 3600109 | 131025 | None | BSR- CDS-15 | Supply and fixing of Anti Climbing Device (12 Mtr GI Barbed Wire
| Each | 154.88 | 154.88 | 2.0 | False | None | None | False | None | False | 309.76 | 0 | 3600110 | 131025 | None | BSR- CDS-15 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
| Set | 26541.86 | 26541.86 | 1.0 | False | None | None | False | None | False | 26541.86 | 0 | 3600111 | 131025 | None | BSR- CDS-15 | Supply and fixing of H-Frame for mounting GOS
| No | 5421.86 | 5421.86 | 1.0 | False | None | None | False | None | False | 5421.86 | 0 | 3600112 | 131025 | None | BSR- CDS-15 | Supply and fixing of DOLO Cut Out
| Set of 3 Nos | 7248.15 | 7248.15 | 1.0 | False | None | None | False | None | False | 7248.15 | 0 | 3600113 | 131025 | None | BSR- 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
| No | 203691.6 | 203691.6 | 1.0 | False | None | None | False | None | False | 203691.6 | 0 | 3600114 | 131025 | None | SR 19-20 6.1 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.
| No | 3716.63 | 3716.63 | 6.0 | False | None | None | False | None | False | 22299.78 | 0 | 3600115 | 131025 | None | SR 19-20-6.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x6mm GI strip
| Rmtr | 142.49 | 142.49 | 60.0 | False | None | None | False | None | False | 8549.4 | 0 | 3600116 | 131025 | None | SR 19-20-6.3.8 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
40x6mm Copper strip
| Rmtr | 1771.77 | 1771.77 | 60.0 | False | None | None | False | None | False | 106306.2 | 0 | 3600117 | 131025 | None | SR 19-20-6.3.10 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600x600x3mm Copper plate
| Each | 8549.1 | 8549.1 | 4.0 | False | None | None | False | None | False | 34196.4 | 0 | 3600118 | 131025 | None | BSR-45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2)
3x95Sqmm.Outdoor
| Set | 4913.87 | 4913.87 | 3.0 | False | None | None | False | None | False | 14741.61 | 0 | 3600119 | 131025 | None | BSR-45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2)
3x95Sqmm.Indoor
| Set | 4523.59 | 4523.59 | 2.0 | False | None | None | False | None | False | 9047.18 | 0 | 3600120 | 131025 | None | BSR-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975."
95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1382246.99 | 1382246.99 | 0.03 | False | None | None | False | None | False | 41467.4097 | 0 | 3600121 | 131025 | None | BSR-38 | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. | Sqm | 1222.89 | 1222.89 | 80.0 | False | None | None | False | None | False | 97831.2 | 0 | 3600122 | 131025 | None | BSR-65.04 | Rubber Hand gloves 15 kV, SEAMLESS Confirming to
ISS (Sample to be verified for seamless before approval)
for electrical purpose
| Pair | 1365.38 | 1365.38 | 2.0 | False | None | None | False | None | False | 2730.76 | 0 | 3600123 | 131025 | None | IT.NO 15.122 | Supplying of first aid box. Complete
| Each | 3717.0 | 3717.0 | 2.0 | False | None | None | False | None | False | 7434.0 | 0 | 3600124 | 131025 | None | MARKET RATE | Supplying of FIRST AID CHART with lamination. Complete
| Each | 309.75 | 309.75 | 2.0 | False | None | None | False | None | False | 619.5 | 0 | 3600125 | 131025 | None | IT.NO 5.42.1 | LT KIOSK
Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
| Sq CM | 0.47 | 0.47 | 110000.0 | False | None | None | False | None | False | 51700.0 | 0 | 3600126 | 131025 | None | IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.
250Amps 4x30x10mm Aluminum Strips
| Rmtr | 3813.64 | 3813.64 | 4.0 | False | None | None | False | None | False | 15254.56 | 0 | 3600127 | 131025 | None | IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
| Rmtr | 340.73 | 340.73 | 8.0 | False | None | None | False | None | False | 2725.84 | 0 | 3600128 | 131025 | None | IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
| Rmtr | 842.52 | 842.52 | 8.0 | False | None | None | False | None | False | 6740.16 | 0 | 3600129 | 131025 | None | IT.NO 5.14 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
FOUR POLE
125Amps 25kA
| Each | 12479.21 | 12479.21 | 2.0 | False | None | None | False | None | False | 24958.42 | 0 | 3600130 | 131025 | None | IT.NO 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps DP
| Each | 1366.62 | 1366.62 | 4.0 | False | None | None | False | None | False | 5466.48 | 0 | 3600131 | 131025 | None | IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
| Each | 574.9 | 574.9 | 3.0 | False | None | None | False | None | False | 1724.7 | 0 | 3600132 | 131025 | None | 10.1.1 | Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class HMounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibr 15KVA/12kw | Set | 432547.3 | 432547.3 | 1.0 | False | None | None | False | None | False | 432547.3 | 0 | 3600133 | 131025 | None | 10.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility.15KVA | Each | 72743.46 | 72743.46 | 1.0 | False | None | None | False | None | False | 72743.46 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(SEPTIC TANK & SOAK PIT)) | 477864.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600134 | 131026 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3600135 | 131026 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3600136 | 131026 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3600137 | 131026 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3600138 | 131026 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.47 | False | None | None | False | None | False | 5997.4389 | 0 | 3600139 | 131026 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3600140 | 131026 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.78 | False | None | None | False | None | False | 197290.2516 | 0 | 3600141 | 131026 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3600142 | 131026 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3600143 | 131026 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3600144 | 131026 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3600145 | 131026 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3600146 | 131026 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3600147 | 131026 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3600148 | 131026 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3600149 | 131026 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(SUMP TANK) | 326860.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600150 | 131027 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3600151 | 131027 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3600152 | 131027 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3600153 | 131027 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3600154 | 131027 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3600155 | 131027 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3600156 | 131027 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3600157 | 131027 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3600158 | 131027 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3600159 | 131027 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3600160 | 131027 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(UPS) | 415116.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600161 | 131028 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3600162 | 131028 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(ACs) | 122781.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600163 | 131029 | None | 6.8.2 | Supplyingof .TRInvertor type splitAirconditionerssuitable
foroperation onA/Csupply singlephase50Hz230Vwith
hermetically sealed inverter compressor with air cooled
condenser, latestR410A/R-32refrigerant fanmotor,start&
runcapacitors, relay&overloadprotector internal unit,with
one indoor&one outdoor unit The condenser unit will be
placedoutsidetheroomavoidnoiseincluding standardlength
of suitable size copper tubing covered with nitrile rubber
insulation tube. suitable capacity 3 core sheathed/ PVC
copper cable and a battery operated wireless remote unit.
3 star - 1.5 Ton capacity | Each | 53435.12 | 53435.12 | 2.0 | False | None | None | False | None | False | 106870.24 | 0 | 3600164 | 131029 | None | 6.10 | Installation charges for split type air conditioner with allied worksforoneindoorandoneoutdoorunit istobemountedon suitableAngle Iron support upto3.0Tonsplit/cassette type
A/C. | Each | 3746.5 | 3746.5 | 2.0 | False | None | None | False | None | False | 7493.0 | 0 | 3600165 | 131029 | None | 9.1.1 | Supplying, erecting, testing and commissioning of voltage
stabilizersuitablefor170to270vinputandloadvariationfrom
no load to full load, with over load protection, spike
suppression, operating at 00 C to 400 C. Range etc.,
complete - 3kVA Capacity | Each | 4209.06 | 4209.06 | 2.0 | False | None | None | False | None | False | 8418.12 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(street lighting system) | 318859.01 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600166 | 131030 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3600167 | 131030 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3600168 | 131030 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3600169 | 131030 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3600170 | 131030 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3600171 | 131030 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3600172 | 131030 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3600173 | 131030 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3600174 | 131030 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3600175 | 131030 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3600176 | 131030 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3600177 | 131030 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3600178 | 131030 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(CC Road) | 821594.59 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600179 | 131031 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 3.6 | False | None | None | False | None | False | 1752.912 | 0 | 3600180 | 131031 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 108.0 | False | None | None | False | None | False | 12711.6 | 0 | 3600181 | 131031 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 108.0 | False | None | None | False | None | False | 14049.72 | 0 | 3600182 | 131031 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 108.0 | False | None | None | False | None | False | 63426.24 | 0 | 3600183 | 131031 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 36.0 | False | None | None | False | None | False | 105220.8 | 0 | 3600184 | 131031 | None | CSR 2023-24 Vol-3, P. No. 26,It. No. 4.17 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 3170.6 | 3170.6 | 54.0 | False | None | None | False | None | False | 171212.4 | 0 | 3600185 | 131031 | None | PWDSR2023-24 V-3 Page No-51 It No-6.6 | Construction of un-reinforced plain cement concrete pavementusing RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedureand thickness as per design, over a prepared sub base. Thesuperplastisiser confirming to IS 9103-1999 Reaffirmed-2008,Coarse aggregates and Fine aggregate confirming to IS:383-2016,transported to site, laid in approved fixed side form work (steelchannel, laying and fixing of 125 micron thick polythene film,wedges, steel plates including levelling the form work). Spreadingthe concrete with shovels, rackers and compacted using needle,suitable plate vibrator and finished in a continuous operation Including provision of separation membrane and Hessian clothfinishing to lines and grades complete including cost of all
materials, labour, all lead & lift, loading charges as per specification& direction of Engineer incharge of the work | Cum | 8392.98 | 8392.98 | 54.0 | False | None | None | False | None | False | 453220.92 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(Compound wall) | 3658914.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600186 | 131032 | None | 1.5 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 194.87 | False | None | None | False | None | False | 72191.5402 | 0 | 3600187 | 131032 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 43.06 | False | None | None | False | None | False | 319521.1322 | 0 | 3600188 | 131032 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenance | Cum | 8412.76 | 8412.76 | 24.3 | False | None | None | False | None | False | 204430.068 | 0 | 3600189 | 131032 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. | Cum | 13242.31 | 13242.31 | 44.5 | False | None | None | False | None | False | 589282.795 | 0 | 3600190 | 131032 | None | 2.11A | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 110837.22 | 110837.22 | 8.36 | False | None | None | False | None | False | 926599.1592 | 0 | 3600191 | 131032 | None | 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 9873.59 | 9873.59 | 74.87 | False | None | None | False | None | False | 739235.6833 | 0 | 3600192 | 131032 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 1144.03 | False | None | None | False | None | False | 525876.2701 | 0 | 3600193 | 131032 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Set of 2 Nos | 193.28 | 193.28 | 1144.03 | False | None | None | False | None | False | 221118.1184 | 0 | 3600194 | 131032 | None | PWD Volume- 2 SR 2023-24 Page No-84 It No-11.25. | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kg | 168.5 | 168.5 | 360.0 | False | None | None | False | None | False | 60660.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(Borewell) | 419515.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600195 | 131033 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3600196 | 131033 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3600197 | 131033 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
| Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3600198 | 131033 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
| Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3600199 | 131033 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Rmtr | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3600200 | 131033 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | Rmtr | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3600201 | 131033 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3600202 | 131033 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3600203 | 131033 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3600204 | 131033 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
| Each | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3600205 | 131033 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3600206 | 131033 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3600207 | 131033 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3600208 | 131033 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3600209 | 131033 | None | V-5P156I13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3600210 | 131033 | None | EleSrP No 12 2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | Rmtr | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3600211 | 131033 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
| Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3600212 | 131033 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
| Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3600213 | 131033 | None | Ele SrP No 44,I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Each | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3600214 | 131033 | None | Ele rP No 47No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Each | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3600215 | 131033 | None | Ele SP No 44,INo 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Each | 2230.29 | 2230.29 | 1.0 | False | None | None | False | None | False | 2230.29 | 0 | 3600216 | 131033 | None | EleSr No 48,I No.6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Each | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC(RWH) | 53000.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600217 | 131034 | None | V-1page5itm1.4. | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 299.84 | 299.84 | 6.79 | False | None | None | False | None | False | 2035.9136 | 0 | 3600218 | 131034 | None | V-1PAGE5ITM1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 6.79 | False | None | None | False | None | False | 2178.911 | 0 | 3600219 | 131034 | None | V-2P175I17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. | Each | 1391.4 | 1391.4 | 28.0 | False | None | None | False | None | False | 38959.2 | 0 | 3600220 | 131034 | None | V-2P175I17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.5 | 1241.5 | 1.13 | False | None | None | False | None | False | 1402.895 | 0 | 3600221 | 131034 | None | V-2P175I17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.5 | 1469.5 | 0.57 | False | None | None | False | None | False | 837.615 | 0 | 3600222 | 131034 | None | V-2P175I17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.9 | 1476.9 | 0.57 | False | None | None | False | None | False | 841.833 | 0 | 3600223 | 131034 | None | V-2P175I17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. | Cum | 1659.0 | 1659.0 | 0.57 | False | None | None | False | None | False | 945.63 | 0 | 3600224 | 131034 | None | V-2P177I17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1449.6 | 1449.6 | 4.0 | False | None | None | False | None | False | 5798.4 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC NURSE QTRS (Civil Works) | 3682939.99 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600225 | 131035 | None | V-3 P.NO 7 IT.NO 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle
| Sqm | 486.92 | 486.92 | 300.0 | False | None | None | False | None | False | 146076.0 | 0 | 3600226 | 131035 | None | V-1 P.NO 8 IT.NO 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
| Cum | 117.71 | 117.71 | 90.0 | False | None | None | False | None | False | 10593.9 | 0 | 3600227 | 131035 | None | V-1 p.NO 8 IT.NO 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 126.38 | 126.38 | 61.03 | False | None | None | False | None | False | 7712.9714 | 0 | 3600228 | 131035 | None | V-1 p.no 8 IT.NO 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
| Cum | 449.76 | 449.76 | 26.15 | False | None | None | False | None | False | 11761.224 | 0 | 3600229 | 131035 | None | V-3 P.NO 3 IT.NO A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)
| Cum | 167.27 | 167.27 | 56.15 | False | None | None | False | None | False | 9392.2105 | 0 | 3600230 | 131035 | None | V-2 P.NO 5 IT.NO 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| Sqm | 146.21 | 146.21 | 139.0 | False | None | None | False | None | False | 20323.19 | 0 | 3600231 | 131035 | None | V-1 P.NO 7 IT.NO 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 329.58 | 329.58 | 61.03 | False | None | None | False | None | False | 20114.2674 | 0 | 3600232 | 131035 | None | V-1 P.NO 7 IT.NO 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 587.29 | 587.29 | 60.8 | False | None | None | False | None | False | 35707.232 | 0 | 3600233 | 131035 | None | V-1 P.NO 15 IT.NO 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 7420.38 | 7420.38 | 25.88 | False | None | None | False | None | False | 192039.4344 | 0 | 3600234 | 131035 | None | V-1 P.NO 15 IT.NO 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 8412.77 | 8412.77 | 11.1 | False | None | None | False | None | False | 93381.747 | 0 | 3600235 | 131035 | None | V-1 P.NO 15 IT.NO 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
PEDESTAL
| Cum | 8568.56 | 8568.56 | 11.77 | False | None | None | False | None | False | 100851.9512 | 0 | 3600236 | 131035 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 14413.42 | 14413.42 | 9.06 | False | None | None | False | None | False | 130585.5852 | 0 | 3600237 | 131035 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
PLINTH BEAM
| Cum | 12717.72 | 12717.72 | 6.15 | False | None | None | False | None | False | 78213.978 | 0 | 3600238 | 131035 | None | V-1 P.N 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
STAIRCASE
GROUND FLOOR
| Cum | 12293.8 | 12293.8 | 2.38 | False | None | None | False | None | False | 29259.244 | 0 | 3600239 | 131035 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
ROOF BEAMS
GROUND FLOOR
| Cum | 13565.57 | 13565.57 | 5.42 | False | None | None | False | None | False | 73525.3894 | 0 | 3600240 | 131035 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
ROOF SLAB
GROUND FLOOR
| Cum | 12717.72 | 12717.72 | 14.11 | False | None | None | False | None | False | 179447.0292 | 0 | 3600241 | 131035 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
LINTELS
GROUND FLOOR
| Cum | 13565.57 | 13565.57 | 1.67 | False | None | None | False | None | False | 22654.5019 | 0 | 3600242 | 131035 | None | V-1 P.NO 15 IT.NO 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11169.16 | 11169.16 | 1.27 | False | None | None | False | None | False | 14184.8332 | 0 | 3600243 | 131035 | None | V-3 P.NO 117 IT.NO 15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
| No | 252.76 | 252.76 | 4.0 | False | None | None | False | None | False | 1011.04 | 0 | 3600244 | 131035 | None | V-2 P.NO 9 IT.NO 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 7915.98 | 7915.98 | 1.33 | False | None | None | False | None | False | 10528.2534 | 0 | 3600245 | 131035 | None | V-1 P.NO 18 IT.NO 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
| t | 110837.23 | 110837.23 | 6.15 | False | None | None | False | None | False | 681648.9645 | 0 | 3600246 | 131035 | None | sr-18-19 P.NO14 IT.NO 4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
| Rmtr | 38.94 | 38.94 | 26.22 | False | None | None | False | None | False | 1021.0068 | 0 | 3600247 | 131035 | None | Data Rate | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.
| Rmtr | 86.14 | 86.14 | 26.22 | False | None | None | False | None | False | 2258.5908 | 0 | 3600248 | 131035 | None | V-2 P.NO 14 IT.NO 6.32 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 9873.6 | 9873.6 | 40.15 | False | None | None | False | None | False | 396425.04 | 0 | 3600249 | 131035 | None | V-2 P.NO 14 IT.NO 6.13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1209.27 | 1209.27 | 32.25 | False | None | None | False | None | False | 38998.9575 | 0 | 3600250 | 131035 | None | V-2 P.NO 100 IT.NO 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 122431.79 | 122431.79 | 0.19 | False | None | None | False | None | False | 23262.0401 | 0 | 3600251 | 131035 | None | V-2 P.NO 105 IT.NO 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1258.83 | 1258.83 | 4.0 | False | None | None | False | None | False | 5035.32 | 0 | 3600252 | 131035 | None | V-2 P.NO 107 IT.NO 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1303.43 | 1303.43 | 4.0 | False | None | None | False | None | False | 5213.72 | 0 | 3600253 | 131035 | None | V-2 P.NO 107 IT.NO 12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
| No | 1226.61 | 1226.61 | 4.0 | False | None | None | False | None | False | 4906.44 | 0 | 3600254 | 131035 | None | V-2 P.NO 107 IT.NO 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with
necessary screws etc. complete"
| No | 293.65 | 293.65 | 4.0 | False | None | None | False | None | False | 1174.6 | 0 | 3600255 | 131035 | None | V-2 P.NO 107 IT.NO 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
| No | 161.07 | 161.07 | 4.0 | False | None | None | False | None | False | 644.28 | 0 | 3600256 | 131035 | None | V-2 P.NO 107 IT.NO 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms
| No | 68.15 | 68.15 | 4.0 | False | None | None | False | None | False | 272.6 | 0 | 3600257 | 131035 | None | V-2 P.NO 108 IT.NO 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)
| No | 340.73 | 340.73 | 4.0 | False | None | None | False | None | False | 1362.92 | 0 | 3600258 | 131035 | None | V-2 P.NO 69 IT.NO 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 74.34 | 74.34 | 24.0 | False | None | None | False | None | False | 1784.16 | 0 | 3600259 | 131035 | None | XI, 18-19 SR, 309 (0115) | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.
| Rmtr | 15.0 | 15.0 | 19.35 | False | None | None | False | None | False | 290.25 | 0 | 3600260 | 131035 | None | V-2 P.NO 106 IT.NO 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial
| Sqm | 4115.96 | 4115.96 | 7.88 | False | None | None | False | None | False | 32433.7648 | 0 | 3600261 | 131035 | None | V-2 (CPWD) P.NO 542 IT.NO 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick
| Sqm | 4317.92 | 4317.92 | 3.15 | False | None | None | False | None | False | 13601.448 | 0 | 3600262 | 131035 | None | V-2 (CPWD) P.NO 541 IT.NO 26.86.2 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).26.86.2 Frame size 45 x 85 mm
| Rmtr | 869.78 | 869.78 | 9.9 | False | None | None | False | None | False | 8610.822 | 0 | 3600263 | 131035 | None | V-2 P.NO 109 IT.NO 12.87 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 8116.69 | 8116.69 | 11.34 | False | None | None | False | None | False | 92043.2646 | 0 | 3600264 | 131035 | None | V-2 P.NO 109 IT.NO 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7085.85 | 7085.85 | 1.08 | False | None | None | False | None | False | 7652.718 | 0 | 3600265 | 131035 | None | V-2 P.NO 110 IT.NO 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 208.16 | 208.16 | 215.41 | False | None | None | False | None | False | 44839.7456 | 0 | 3600266 | 131035 | None | V-2 P.NO 81 IT.NO 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
FOR WATER TANK STAND
| Kg | 182.14 | 182.14 | 102.75 | False | None | None | False | None | False | 18714.885 | 0 | 3600267 | 131035 | None | V-2 P.NO 41 IT.NO 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 386.57 | 386.57 | 434.01 | False | None | None | False | None | False | 167775.2457 | 0 | 3600268 | 131035 | None | V-2 P.NO 43 IT.NO 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 261.43 | 261.43 | 49.3 | False | None | None | False | None | False | 12888.499 | 0 | 3600269 | 131035 | None | V-2 P.NO 50 IT.NO 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 123.9 | 123.9 | 483.31 | False | None | None | False | None | False | 59882.109 | 0 | 3600270 | 131035 | None | V-2 P.NO 41 IT.NO 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Outside)
| Sqm | 432.42 | 432.42 | 218.46 | False | None | None | False | None | False | 94466.4732 | 0 | 3600271 | 131035 | None | V-2 P.NO 42 IT.NO 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 438.61 | 438.61 | 14.02 | False | None | None | False | None | False | 6149.3122 | 0 | 3600272 | 131035 | None | P.NO118,18-19 SR ,IT.NO 15.36 | KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )
| Rmtr | 38.78 | 38.78 | 301.69 | False | None | None | False | None | False | 11699.5382 | 0 | 3600273 | 131035 | None | P.NO 70,18-19 SR,IT.NO 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.
| Sqm | 270.18 | 270.18 | 5.0 | False | None | None | False | None | False | 1350.9 | 0 | 3600274 | 131035 | None | V-2 P.NO 54 IT.NO 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 64.43 | 64.43 | 166.05 | False | None | None | False | None | False | 10698.6015 | 0 | 3600275 | 131035 | None | V-2 P.NO 61 IT.NO 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm
| Sqm | 1455.83 | 1455.83 | 47.9 | False | None | None | False | None | False | 69734.257 | 0 | 3600276 | 131035 | None | V-2 P.NO 63 IT.NO 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent.
| Sqm | 3055.38 | 3055.38 | 26.68 | False | None | None | False | None | False | 81517.5384 | 0 | 3600277 | 131035 | None | V-2,P.NO 65,IT.NO 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.
| Sqm | 2044.35 | 2044.35 | 5.46 | False | None | None | False | None | False | 11162.151 | 0 | 3600278 | 131035 | None | V-2,P.NO 41,IT.NO 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 365.51 | 365.51 | 40.97 | False | None | None | False | None | False | 14974.9447 | 0 | 3600279 | 131035 | None | V-2,P.NO 60,IT.NO 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 1101.48 | 1101.48 | 7.3 | False | None | None | False | None | False | 8040.804 | 0 | 3600280 | 131035 | None | V-2 P.NO 65 IT.NO 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1795.32 | 1795.32 | 40.97 | False | None | None | False | None | False | 73554.2604 | 0 | 3600281 | 131035 | None | V-2 P.NO 83 IT.NO 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 700.04 | 700.04 | 337.83 | False | None | None | False | None | False | 236494.5132 | 0 | 3600282 | 131035 | None | V-2 P.NO 48 IT.NO 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 157.36 | 157.36 | 483.31 | False | None | None | False | None | False | 76053.6616 | 0 | 3600283 | 131035 | None | V-2 P.NO 45 IT.NO 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 193.29 | 193.29 | 196.61 | False | None | None | False | None | False | 38002.7469 | 0 | 3600284 | 131035 | None | V-2 P.NO 45 IT.NO 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
| Sqm | 350.64 | 350.64 | 21.85 | False | None | None | False | None | False | 7661.484 | 0 | 3600285 | 131035 | None | V-2 P.NO 47 IT.NO 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 61.95 | 61.95 | 6.21 | False | None | None | False | None | False | 384.7095 | 0 | 3600286 | 131035 | None | V-2 P.NO 48 IT.NO 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 142.49 | 142.49 | 6.21 | False | None | None | False | None | False | 884.8629 | 0 | 3600287 | 131035 | None | V-2 P.NO 47 IT.NO 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 65.67 | 65.67 | 18.9 | False | None | None | False | None | False | 1241.163 | 0 | 3600288 | 131035 | None | V-2 P.NO 46 IT.NO 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade.Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brandandmanufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeas per specifications and as per directions of Engineer-in-charge.
| Sqm | 170.99 | 170.99 | 18.9 | False | None | None | False | None | False | 3231.711 | 0 | 3600289 | 131035 | None | V-2 P.NO 75 IT.NO 11.5.1 | Providing and fixing 1mm thick M.S.steel garage door with frame and diagonal braces of size 40x40x6 mm angle Iron 3.15mm thick M.S.Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications.
| Sqm | 5548.25 | 5548.25 | 2.1 | False | None | None | False | None | False | 11651.325 | 0 | 3600290 | 131035 | None | data rate | Providing & laying Screed Concreete using 12mm & down size graded granite/trap metal,average thickness of 7.50cms including finishing etc complete as per specification with all lead & lift as directed by Engineer incharge.(Data Rate) - With all lead and lifts etc., complete as per specification and as per the directions of the Engineer-In-Charge of the work.
| Sqm | 585.28 | 585.28 | 139.0 | False | None | None | False | None | False | 81353.92 | 0 | 3600291 | 131035 | None | V-2 P.NO 26 IT.NO 7.38 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard
film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 703.76 | 703.76 | 8.4 | False | None | None | False | None | False | 5911.584 | 0 | 3600292 | 131035 | None | V-5 P.NO 34 IT.NO 3713 | PVC pipes of 6 Kg/cm2 for 110mm(1.894)
| Rmtr | 443.57 | 443.57 | 60.0 | False | None | None | False | None | False | 26614.2 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC NUSE QTRS (Internal WS AND SANITARY) | 276216.78 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600293 | 131036 | None | V-2 P.NO 28 IT.NO 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
40mm dia pipes, From wash basin waste lines
| Rmtr | 113.99 | 113.99 | 10.0 | False | None | None | False | None | False | 1139.9 | 0 | 3600294 | 131036 | None | V-5 P.NO 187 IT.NO T090 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
50mm nominal bore pipes, From Sink & Urinal lines
| Rmtr | 213.38 | 213.38 | 10.0 | False | None | None | False | None | False | 2133.8 | 0 | 3600295 | 131036 | None | V-5 P.NO 34 IT.NO 3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines
| Rmtr | 337.73 | 337.73 | 40.0 | False | None | None | False | None | False | 13509.2 | 0 | 3600296 | 131036 | None | V-5 P.NO 34 IT.NO 3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines
| Rmtr | 630.94 | 630.94 | 35.0 | False | None | None | False | None | False | 22082.9 | 0 | 3600297 | 131036 | None | V-2 P.NO 119 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
| Rmtr | 244.08 | 244.08 | 15.0 | False | None | None | False | None | False | 3661.2 | 0 | 3600298 | 131036 | None | V-2 P.NO 119 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
| Rmtr | 360.55 | 360.55 | 10.0 | False | None | None | False | None | False | 3605.5 | 0 | 3600299 | 131036 | None | V-5 P.NO 34 IT.NO 3711 | PVC pipe - OD 75mm and 6 Kg/sqcm - (Shaft Drainage)
| Rmtr | 337.01 | 337.01 | 20.0 | False | None | None | False | None | False | 6740.2 | 0 | 3600300 | 131036 | None | V-5 P.NO 34 IT.NO 3713 | PVC pipe - OD 110mm and 6 Kg/sqcm - (Shaft Drainage)
| Rmtr | 630.94 | 630.94 | 20.0 | False | None | None | False | None | False | 12618.8 | 0 | 3600301 | 131036 | None | V-2 P.NO 128 IT.NO 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| No | 1511.58 | 1511.58 | 2.0 | False | None | None | False | None | False | 3023.16 | 0 | 3600302 | 131036 | None | V-2 P.NO 116 IT.NO 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
| No | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3600303 | 131036 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
| No | 6891.32 | 6891.32 | 1.0 | False | None | None | False | None | False | 6891.32 | 0 | 3600304 | 131036 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| No | 614.54 | 614.54 | 1.0 | False | None | None | False | None | False | 614.54 | 0 | 3600305 | 131036 | None | V-2 P.NO 123 IT.NO 14.3 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and
mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good
the walls and floors wherever required
| No | 7192.4 | 7192.4 | 1.0 | False | None | None | False | None | False | 7192.4 | 0 | 3600306 | 131036 | None | V-2 P.NO 126 IT.NO14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm
| No | 5986.85 | 5986.85 | 2.0 | False | None | None | False | None | False | 11973.7 | 0 | 3600307 | 131036 | None | V-2 P.NO A-14 IT.NO 91 | C.P. Brass stop cock (concealed) 15 mm
| No | 650.48 | 650.48 | 2.0 | False | None | None | False | None | False | 1300.96 | 0 | 3600308 | 131036 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
| No | 3818.6 | 3818.6 | 1.0 | False | None | None | False | None | False | 3818.6 | 0 | 3600309 | 131036 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm dia
| Rmtr | 382.85 | 382.85 | 20.0 | False | None | None | False | None | False | 7657.0 | 0 | 3600310 | 131036 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
GROUND FLOOR
20 mm dia
| Rmtr | 469.58 | 469.58 | 20.0 | False | None | None | False | None | False | 9391.6 | 0 | 3600311 | 131036 | None | V-2 P.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
GROUND FLOOR
25 mm dia
| Rmtr | 591.0 | 591.0 | 25.0 | False | None | None | False | None | False | 14775.0 | 0 | 3600312 | 131036 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
32 mm dia
| Rmtr | 690.12 | 690.12 | 10.0 | False | None | None | False | None | False | 6901.2 | 0 | 3600313 | 131036 | None | V-2 P.NO 120 IT.NO 13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)"
External & Shafts & Terrace
40mm DWS
| Rmtr | 591.0 | 591.0 | 45.0 | False | None | None | False | None | False | 26595.0 | 0 | 3600314 | 131036 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)"
External & Shafts & Terrace
50mm DWS
| Rmtr | 893.32 | 893.32 | 15.0 | False | None | None | False | None | False | 13399.8 | 0 | 3600315 | 131036 | None | V-2,A-13,IT.NO 66 | Brass bib-cock 15 mm dia
| No | 354.35 | 354.35 | 4.0 | False | None | None | False | None | False | 1417.4 | 0 | 3600316 | 131036 | None | V-2 IT.NO 13.34 | KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. (For 1000 litre capacity)
Specification No.KBS 13.22 | No | 11.15 | 11.15 | 1000.0 | False | None | None | False | None | False | 11150.0 | 0 | 3600317 | 131036 | None | Market Rate | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards
Ground Toilet
10Cms X 7.5Cms
| No | 371.7 | 371.7 | 10.0 | False | None | None | False | None | False | 3717.0 | 0 | 3600318 | 131036 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
| No | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 | 3600319 | 131036 | None | Market Rate | Drilling holes of 2.50 cms dia (roof/chajja/stone).
-do- in slabs upto 7.50 cms thick
| No | 154.58 | 154.58 | 5.0 | False | None | None | False | None | False | 772.9 | 0 | 3600320 | 131036 | None | Market Rate | Drilling holes of 2.50 cms dia (roof/chajja/stone).
-do- in slabs upto 10 cms thick
| No | 185.26 | 185.26 | 5.0 | False | None | None | False | None | False | 926.3 | 0 | 3600321 | 131036 | None | Market Rate | Air Vent Cowel
75mm
| No | 413.0 | 413.0 | 10.0 | False | None | None | False | None | False | 4130.0 | 0 | 3600322 | 131036 | None | Market Rate | Air Vent Cowel
110mm
| No | 590.0 | 590.0 | 10.0 | False | None | None | False | None | False | 5900.0 | 0 | 3600323 | 131036 | None | Market Rate | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards
| No | 5664.0 | 5664.0 | 2.0 | False | None | None | False | None | False | 11328.0 | 0 | 3600324 | 131036 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
| No | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3600325 | 131036 | None | Market Rate | Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent )
| No | 1996.56 | 1996.56 | 2.0 | False | None | None | False | None | False | 3993.12 | 0 | 3600326 | 131036 | None | Market Rate | Providing and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot.
| Each | 295.0 | 295.0 | 5.0 | False | None | None | False | None | False | 1475.0 | 0 | 3600327 | 131036 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
c) 50mm dia | No | 3304.0 | 3304.0 | 2.0 | False | None | None | False | None | False | 6608.0 | 0 | 3600328 | 131036 | None | 8.3.1 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. | No | 37498.0 | 37498.0 | 1.0 | False | None | None | False | None | False | 37498.0 | 0 | 3600329 | 131036 | None | CPWD SR, V-2,377,1927 | Brass full way valve with C.I. wheel (screwed end) 25 mm dia | Each | 442.5 | 442.5 | 3.0 | False | None | None | False | None | False | 1327.5 | 0 | 3600330 | 131036 | None | CPWD SR, V-2,377,1928 | Brass full way valve with C.I. wheel (screwed end) 32 mm dia | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3600331 | 131036 | None | CPWD SR, V-2,377,1929 | Brass full way valve with C.I. wheel (screwed end) 40 mm dia | Each | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | Barur PHC NURSE QTRS(INERNAL ELECTRICAL) | 150783.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600332 | 131037 | None | IT.NO 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Short point up to 3Mtr from tapping point to out let via switch box
| Point | 333.29 | 333.29 | 6.0 | False | None | None | False | None | False | 1999.74 | 0 | 3600333 | 131037 | None | IT.NO 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box
| Point | 469.58 | 469.58 | 7.0 | False | None | None | False | None | False | 3287.06 | 0 | 3600334 | 131037 | None | IT.NO 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box
| Point | 687.65 | 687.65 | 7.0 | False | None | None | False | None | False | 4813.55 | 0 | 3600335 | 131037 | None | IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
| Each | 170.98 | 170.98 | 9.0 | False | None | None | False | None | False | 1538.82 | 0 | 3600336 | 131037 | None | IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
| Each | 197.0 | 197.0 | 1.0 | False | None | None | False | None | False | 197.0 | 0 | 3600337 | 131037 | None | IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
| Each | 219.3 | 219.3 | 1.0 | False | None | None | False | None | False | 219.3 | 0 | 3600338 | 131037 | None | IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8Way
| Each | 272.58 | 272.58 | 3.0 | False | None | None | False | None | False | 817.74 | 0 | 3600339 | 131037 | None | IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
| Each | 323.38 | 323.38 | 2.0 | False | None | None | False | None | False | 646.76 | 0 | 3600340 | 131037 | None | IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
| Each | 216.83 | 216.83 | 1.0 | False | None | None | False | None | False | 216.83 | 0 | 3600341 | 131037 | None | IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4Moudule
| Each | 216.83 | 216.83 | 1.0 | False | None | None | False | None | False | 216.83 | 0 | 3600342 | 131037 | None | IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6Moudule
| Each | 289.93 | 289.93 | 1.0 | False | None | None | False | None | False | 289.93 | 0 | 3600343 | 131037 | None | IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8Moudule
| Each | 351.88 | 351.88 | 3.0 | False | None | None | False | None | False | 1055.64 | 0 | 3600344 | 131037 | None | IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10Moudule
| Each | 426.22 | 426.22 | 2.0 | False | None | None | False | None | False | 852.44 | 0 | 3600345 | 131037 | None | IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way.
| Each | 126.38 | 126.38 | 28.0 | False | None | None | False | None | False | 3538.64 | 0 | 3600346 | 131037 | None | IT.NO 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way.
| Each | 205.67 | 205.67 | 4.0 | False | None | None | False | None | False | 822.68 | 0 | 3600347 | 131037 | None | IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket.
| Each | 211.87 | 211.87 | 10.0 | False | None | None | False | None | False | 2118.7 | 0 | 3600348 | 131037 | None | IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
| Each | 442.32 | 442.32 | 3.0 | False | None | None | False | None | False | 1326.96 | 0 | 3600349 | 131037 | None | IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
| Each | 403.91 | 403.91 | 3.0 | False | None | None | False | None | False | 1211.73 | 0 | 3600350 | 131037 | None | IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
| Each | 292.4 | 292.4 | 3.0 | False | None | None | False | None | False | 877.2 | 0 | 3600351 | 131037 | None | IT.NO 3.6.12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket
| Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3600352 | 131037 | None | IT.NO 13.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.
Ding Dong Bell
| Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3600353 | 131037 | None | IT.NO 1.12 | Supplyin and Fixing Metal Fan Box with Round Hook.
| No | 144.96 | 144.96 | 3.0 | False | None | None | False | None | False | 434.88 | 0 | 3600354 | 131037 | None | ITM 1.2.1 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
| Rmtr | 81.77 | 81.77 | 160.0 | False | None | None | False | None | False | 13083.2 | 0 | 3600355 | 131037 | None | ITM 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
| Rmtr | 96.64 | 96.64 | 70.0 | False | None | None | False | None | False | 6764.8 | 0 | 3600356 | 131037 | None | ITM 1.2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
| Rmtr | 127.66 | 127.66 | 20.0 | False | None | None | False | None | False | 2553.2 | 0 | 3600357 | 131037 | None | ITM 1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)
19/20mm dia 2mm thick
| Rmtr | 84.25 | 84.25 | 75.0 | False | None | None | False | None | False | 6318.75 | 0 | 3600358 | 131037 | None | ITM 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)
25mm dia 2mm thick
| Rmtr | 97.88 | 97.88 | 40.0 | False | None | None | False | None | False | 3915.2 | 0 | 3600359 | 131037 | None | ITM 1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)
32mm dia 2.5mm thick
| Rmtr | 122.66 | 122.66 | 10.0 | False | None | None | False | None | False | 1226.6 | 0 | 3600360 | 131037 | None | ITM 2.5.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5)
1.5 sqmm
| Rmtr | 32.21 | 32.21 | 75.0 | False | None | None | False | None | False | 2415.75 | 0 | 3600361 | 131037 | None | ITM 2.5.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5)
2.5 sqmm
| Rmtr | 52.04 | 52.04 | 180.0 | False | None | None | False | None | False | 9367.2 | 0 | 3600362 | 131037 | None | ITM 2.5.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5)
4 sqmm
| Rmtr | 78.06 | 78.06 | 60.0 | False | None | None | False | None | False | 4683.6 | 0 | 3600363 | 131037 | None | BSR-32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
2 core 10 sqmm
| Km | 125279.01 | 125279.01 | 0.1 | False | None | None | False | None | False | 12527.901 | 0 | 3600364 | 131037 | None | BSR-31 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
2.5 sqmm to 25 sqmm
| Km | 20021.0 | 20021.0 | 0.1 | False | None | None | False | None | False | 2002.1 | 0 | 3600365 | 131037 | None | SR 19-20 ITM 6.11 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
19/20mm
| Each | 84.25 | 84.25 | 4.0 | False | None | None | False | None | False | 337.0 | 0 | 3600366 | 131037 | None | SR 19-20 ITM 6.6.2 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)
In soil (hard)
| Rmtr | 126.38 | 126.38 | 60.0 | False | None | None | False | None | False | 7582.8 | 0 | 3600367 | 131037 | None | ITM 8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.
2Pair
| Rmtr | 26.02 | 26.02 | 20.0 | False | None | None | False | None | False | 520.4 | 0 | 3600368 | 131037 | None | ITM8.3 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.
MCB DB
| Rmtr | 54.52 | 54.52 | 25.0 | False | None | None | False | None | False | 1363.0 | 0 | 3600369 | 131037 | None | ITM5.18.8 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
Double Door
12 Way SP & N | Each | 3771.52 | 3771.52 | 1.0 | False | None | None | False | None | False | 3771.52 | 0 | 3600370 | 131037 | None | ITM5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps SP
| Each | 514.19 | 514.19 | 10.0 | False | None | None | False | None | False | 5141.9 | 0 | 3600371 | 131037 | None | ITM 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
| Each | 6538.2 | 6538.2 | 1.0 | False | None | None | False | None | False | 6538.2 | 0 | 3600372 | 131037 | None | ITM 11.3 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fighting 1 x4'- 20/22 w
| Each | 854.91 | 854.91 | 6.0 | False | None | None | False | None | False | 5129.46 | 0 | 3600373 | 131037 | None | ITM 12.46 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
| Each | 183.37 | 183.37 | 8.0 | False | None | None | False | None | False | 1466.96 | 0 | 3600374 | 131037 | None | ITM11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
7 W, 6500K
| Each | 184.61 | 184.61 | 3.0 | False | None | None | False | None | False | 553.83 | 0 | 3600375 | 131037 | None | itm11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
12 W, 6500K | Each | 333.29 | 333.29 | 1.0 | False | None | None | False | None | False | 333.29 | 0 | 3600376 | 131037 | None | Itm 11.11.7 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
18W, 6500K | Each | 527.81 | 527.81 | 2.0 | False | None | None | False | None | False | 1055.62 | 0 | 3600377 | 131037 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply | No | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3600378 | 131037 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1849.0 | 1849.0 | 2.0 | False | None | None | False | None | False | 3698.0 | 0 | 3600379 | 131037 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod
blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | Each | 3697.18 | 3697.18 | 3.0 | False | None | None | False | None | False | 11091.54 | 0 | 3600380 | 131037 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
| Each | 151.15 | 151.15 | 6.0 | False | None | None | False | None | False | 906.9 | 0 | 3600381 | 131037 | None | 13.10 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 211.86 | 211.86 | 3.0 | False | None | None | False | None | False | 635.58 | 0 | 3600382 | 131037 | None | 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 875.97 | 875.97 | 2.0 | False | None | None | False | None | False | 1751.94 | 0 | 3600383 | 131037 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, e | Each | 1810.18 | 1810.18 | 1.0 | False | None | None | False | None | False | 1810.18 | 0 | 3600384 | 131037 | None | 13.4.1 | Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.
Single bracket 1.5 Mtr. Length
| Each | 1810.18 | 1810.18 | 1.0 | False | None | None | False | None | False | 1810.18 | 0 | 3600385 | 131037 | None | 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 200.71 | 200.71 | 1.0 | False | None | None | False | None | False | 200.71 | 0 | 3600386 | 131037 | None | 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps DP
| Each | 915.62 | 915.62 | 1.0 | False | None | None | False | None | False | 915.62 | 0 | 3600387 | 131037 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers
32Amps
| Each | 298.59 | 298.59 | 1.0 | False | None | None | False | None | False | 298.59 | 0 | 3600388 | 131037 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
| Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(Civil Works) | 19709674.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600389 | 131038 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle | 100 Sqm | 486.93 | 486.93 | 20.0 | False | None | None | False | None | False | 9738.6 | 0 | 3600390 | 131038 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.71 | 117.71 | 222.09 | False | None | None | False | None | False | 26142.2139 | 0 | 3600391 | 131038 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 126.38 | 126.38 | 670.52 | False | None | None | False | None | False | 84740.3176 | 0 | 3600392 | 131038 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.76 | 449.76 | 167.63 | False | None | None | False | None | False | 75393.2688 | 0 | 3600393 | 131038 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) | Cum | 167.27 | 167.27 | 100.0 | False | None | None | False | None | False | 16727.0 | 0 | 3600394 | 131038 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 570.14 | False | None | None | False | None | False | 83354.468 | 0 | 3600395 | 131038 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 670.52 | False | None | None | False | None | False | 220983.2764 | 0 | 3600396 | 131038 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.29 | 587.29 | 143.97 | False | None | None | False | None | False | 84552.1413 | 0 | 3600397 | 131038 | None | V-1page 15 itm2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 123.48 | False | None | None | False | None | False | 916267.2876 | 0 | 3600398 | 131038 | None | V-1page15 itm 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Formwork, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates | Cum | 8412.76 | 8412.76 | 94.25 | False | None | None | False | None | False | 792902.63 | 0 | 3600399 | 131038 | None | V-1page16 itm 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 14413.41 | 14413.41 | 37.06 | False | None | None | False | None | False | 534160.9746 | 0 | 3600400 | 131038 | None | V-1page15itm 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7702.86 | 7702.86 | 6.96 | False | None | None | False | None | False | 53611.9056 | 0 | 3600401 | 131038 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy | No | 252.76 | 252.76 | 30.0 | False | None | None | False | None | False | 7582.8 | 0 | 3600402 | 131038 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3600403 | 131038 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings | Tonne | 110837.22 | 110837.22 | 37.25 | False | None | None | False | None | False | 4128686.445 | 0 | 3600404 | 131038 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS | Rmtr | 38.94 | 38.94 | 111.0 | False | None | None | False | None | False | 4322.34 | 0 | 3600405 | 131038 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. | Rmtr | 86.14 | 86.14 | 111.0 | False | None | None | False | None | False | 9561.54 | 0 | 3600406 | 131038 | None | V-2PAGE 9 ITM5.3 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7688.0 | 7688.0 | 17.19 | False | None | None | False | None | False | 132156.72 | 0 | 3600407 | 131038 | None | V-2PAGE 14 ITM 6.32 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9873.59 | 9873.59 | 199.58 | False | None | None | False | None | False | 1970571.0922 | 0 | 3600408 | 131038 | None | V-2page 14 itm 6.13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 1209.26 | 1209.26 | 86.23 | False | None | None | False | None | False | 104274.4898 | 0 | 3600409 | 131038 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 122431.79 | 122431.79 | 0.99 | False | None | None | False | None | False | 121207.4721 | 0 | 3600410 | 131038 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1258.82 | 1258.82 | 14.0 | False | None | None | False | None | False | 17623.48 | 0 | 3600411 | 131038 | None | V-2page 104 itm 12.51 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1314.58 | 1314.58 | 14.0 | False | None | None | False | None | False | 18404.12 | 0 | 3600412 | 131038 | None | V-2 page 105 itm 12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 1226.61 | 1226.61 | 14.0 | False | None | None | False | None | False | 17172.54 | 0 | 3600413 | 131038 | None | V-2page 105 itm 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with
necessary screws etc. complete | Nos | 293.64 | 293.64 | 28.0 | False | None | None | False | None | False | 8221.92 | 0 | 3600414 | 131038 | None | V-2page 105itm 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 161.07 | 161.07 | 28.0 | False | None | None | False | None | False | 4509.96 | 0 | 3600415 | 131038 | None | V-2page105 itm 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 68.15 | 68.15 | 14.0 | False | None | None | False | None | False | 954.1 | 0 | 3600416 | 131038 | None | V-2page107itm12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Nos | 340.73 | 340.73 | 28.0 | False | None | None | False | None | False | 9540.44 | 0 | 3600417 | 131038 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | Nos | 74.34 | 74.34 | 84.0 | False | None | None | False | None | False | 6244.56 | 0 | 3600418 | 131038 | None | XI page 18-19 SR313 (0115) | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Rmtr | 15.0 | 15.0 | 105.8 | False | None | None | False | None | False | 1587.0 | 0 | 3600419 | 131038 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 4115.96 | 4115.96 | 41.21 | False | None | None | False | None | False | 169618.7116 | 0 | 3600420 | 131038 | None | V-2page109 itm 12.87 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 8116.69 | 8116.69 | 77.31 | False | None | None | False | None | False | 627501.3039 | 0 | 3600421 | 131038 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7085.84 | 7085.84 | 6.48 | False | None | None | False | None | False | 45916.2432 | 0 | 3600422 | 131038 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 208.15 | 208.15 | 2159.01 | False | None | None | False | None | False | 449397.9315 | 0 | 3600423 | 131038 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3600424 | 131038 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 168.5 | 168.5 | 120.96 | False | None | None | False | None | False | 20381.76 | 0 | 3600425 | 131038 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) | Sqm | 386.57 | 386.57 | 1049.85 | False | None | None | False | None | False | 405840.5145 | 0 | 3600426 | 131038 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 261.43 | 261.43 | 531.95 | False | None | None | False | None | False | 139067.6885 | 0 | 3600427 | 131038 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 123.9 | 123.9 | 1581.8 | False | None | None | False | None | False | 195985.02 | 0 | 3600428 | 131038 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) | Sqm | 432.41 | 432.41 | 1016.08 | False | None | None | False | None | False | 439363.1528 | 0 | 3600429 | 131038 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 438.61 | 438.61 | 29.15 | False | None | None | False | None | False | 12785.4815 | 0 | 3600430 | 131038 | None | 118page18-19 SR15.36 | Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) | Rmtr | 36.58 | 36.58 | 800.0 | False | None | None | False | None | False | 29264.0 | 0 | 3600431 | 131038 | None | 18-19 SR0.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. | Sqm | 254.88 | 254.88 | 20.0 | False | None | None | False | None | False | 5097.6 | 0 | 3600432 | 131038 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | Rmtr | 64.43 | 64.43 | 709.5 | False | None | None | False | None | False | 45713.085 | 0 | 3600433 | 131038 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm | Sqm | 1455.83 | 1455.83 | 293.21 | False | None | None | False | None | False | 426863.9143 | 0 | 3600434 | 131038 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3600435 | 131038 | None | V-2page63 itm 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent. | Sqm | 3055.37 | 3055.37 | 214.93 | False | None | None | False | None | False | 656690.6741 | 0 | 3600436 | 131038 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 365.51 | 365.51 | 891.34 | False | None | None | False | None | False | 325793.6834 | 0 | 3600437 | 131038 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 1101.47 | 1101.47 | 29.98 | False | None | None | False | None | False | 33022.0706 | 0 | 3600438 | 131038 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1795.31 | 1795.31 | 891.34 | False | None | None | False | None | False | 1600231.6154 | 0 | 3600439 | 131038 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 700.04 | 700.04 | 260.78 | False | None | None | False | None | False | 182556.4312 | 0 | 3600440 | 131038 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 157.35 | 157.35 | 1581.8 | False | None | None | False | None | False | 248896.23 | 0 | 3600441 | 131038 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 193.28 | 193.28 | 762.06 | False | None | None | False | None | False | 147290.9568 | 0 | 3600442 | 131038 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 61.95 | 61.95 | 83.79 | False | None | None | False | None | False | 5190.7905 | 0 | 3600443 | 131038 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 142.49 | 142.49 | 83.79 | False | None | None | False | None | False | 11939.2371 | 0 | 3600444 | 131038 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 65.67 | 65.67 | 98.89 | False | None | None | False | None | False | 6494.1063 | 0 | 3600445 | 131038 | None | V-2page49itm 8.47 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.27 | 167.27 | 98.89 | False | None | None | False | None | False | 16541.3303 | 0 | 3600446 | 131038 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3600447 | 131038 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 5548.24 | 5548.24 | 3.15 | False | None | None | False | None | False | 17476.956 | 0 | 3600448 | 131038 | None | LQR | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.
System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification.
Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.
| Sqm | 1593.0 | 1593.0 | 633.5 | False | None | None | False | None | False | 1009165.5 | 0 | 3600449 | 131038 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications | Sqm | 411.35 | 411.35 | 16.34 | False | None | None | False | None | False | 6721.459 | 0 | 3600450 | 131038 | None | V-2PAGE27ITM 7.40 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. | Sqm | 2118.69 | 2118.69 | 48.84 | False | None | None | False | None | False | 103476.8196 | 0 | 3600451 | 131038 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9326.32 | 9326.32 | 20.24 | False | None | None | False | None | False | 188764.7168 | 0 | 3600452 | 131038 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 44.58 | False | None | None | False | None | False | 566955.9576 | 0 | 3600453 | 131038 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 13565.56 | 13565.56 | 30.15 | False | None | None | False | None | False | 409001.634 | 0 | 3600454 | 131038 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 87.68 | False | None | None | False | None | False | 1115089.6896 | 0 | 3600455 | 131038 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 4.32 | False | None | None | False | None | False | 54940.5504 | 0 | 3600456 | 131038 | None | V1P16I2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12717.72 | 12717.72 | 13.25 | False | None | None | False | None | False | 168509.79 | 0 | 3600457 | 131038 | None | ITEM 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops | Sqm | 350.64 | 350.64 | 254.02 | False | None | None | False | None | False | 89069.5728 | 0 | 3600458 | 131038 | None | 12.94.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(Internal WS AND SANITARY) | 1166957.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600459 | 131039 | None | V-2 P.NO 135 IT.NO 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
40mm dia pipes, From wash basin waste lines
| Rmtr | 113.99 | 113.99 | 40.0 | False | None | None | False | None | False | 4559.6 | 0 | 3600460 | 131039 | None | V-5 P.NO 187 IT.NO T090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
50mm nominal bore pipes, From Sink & Urinal lines
| Rmtr | 213.38 | 213.38 | 20.0 | False | None | None | False | None | False | 4267.6 | 0 | 3600461 | 131039 | None | V-5 P.NO 34 IT.NO 3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines
| Rmtr | 337.73 | 337.73 | 50.0 | False | None | None | False | None | False | 16886.5 | 0 | 3600462 | 131039 | None | V-5 P.NO 34 IT.NO 3713 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines
| Rmtr | 630.94 | 630.94 | 180.0 | False | None | None | False | None | False | 113569.2 | 0 | 3600463 | 131039 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
| Rmtr | 244.08 | 244.08 | 25.0 | False | None | None | False | None | False | 6102.0 | 0 | 3600464 | 131039 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
| Rmtr | 360.55 | 360.55 | 60.0 | False | None | None | False | None | False | 21633.0 | 0 | 3600465 | 131039 | None | V-2 P.NO 128 IT.NO 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| No | 1511.58 | 1511.58 | 20.0 | False | None | None | False | None | False | 30231.6 | 0 | 3600466 | 131039 | None | V-2 P.NO 116 IT.NO 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
| No | 345.68 | 345.68 | 3.0 | False | None | None | False | None | False | 1037.04 | 0 | 3600467 | 131039 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
| No | 6891.32 | 6891.32 | 3.0 | False | None | None | False | None | False | 20673.96 | 0 | 3600468 | 131039 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| No | 614.54 | 614.54 | 3.0 | False | None | None | False | None | False | 1843.62 | 0 | 3600469 | 131039 | None | V-2 P.NO 123 IT.NO 14.3 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and
mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good
the walls and floors wherever required
| No | 7192.4 | 7192.4 | 8.0 | False | None | None | False | None | False | 57539.2 | 0 | 3600470 | 131039 | None | V-2 P.NO 178 IT.NO 20.44.2 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm
| No | 4394.73 | 4394.73 | 10.0 | False | None | None | False | None | False | 43947.3 | 0 | 3600471 | 131039 | None | V-2 P.NO 124 IT.NO14.4.4 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern
| No | 16193.73 | 16193.73 | 4.0 | False | None | None | False | None | False | 64774.92 | 0 | 3600472 | 131039 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
| No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3600473 | 131039 | None | V-2 P.NO 126 IT.NO 14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm
| No | 5986.85 | 5986.85 | 2.0 | False | None | None | False | None | False | 11973.7 | 0 | 3600474 | 131039 | None | V-2 P.NO A-14 IT.NO 91 | C.P. Brass stop cock (concealed) 15 mm
| No | 650.48 | 650.48 | 10.0 | False | None | None | False | None | False | 6504.8 | 0 | 3600475 | 131039 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
| No | 3818.6 | 3818.6 | 5.0 | False | None | None | False | None | False | 19093.0 | 0 | 3600476 | 131039 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia | Rmtr | 382.85 | 382.85 | 60.0 | False | None | None | False | None | False | 22971.0 | 0 | 3600477 | 131039 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia | Rmtr | 469.58 | 469.58 | 50.0 | False | None | None | False | None | False | 23479.0 | 0 | 3600478 | 131039 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
| Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3600479 | 131039 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
| Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3600480 | 131039 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
| Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3600481 | 131039 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
| Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3600482 | 131039 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
| Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3600483 | 131039 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
| Rmtr | 893.32 | 893.32 | 25.0 | False | None | None | False | None | False | 22333.0 | 0 | 3600484 | 131039 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
| Rmtr | 591.0 | 591.0 | 150.0 | False | None | None | False | None | False | 88650.0 | 0 | 3600485 | 131039 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
| Rmtr | 1734.6 | 1734.6 | 23.0 | False | None | None | False | None | False | 39895.8 | 0 | 3600486 | 131039 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
| Rmtr | 893.32 | 893.32 | 25.0 | False | None | None | False | None | False | 22333.0 | 0 | 3600487 | 131039 | None | CPWD SR, V-2,P.NO 109,IT.NO 1927 | Brass full way valve with C.I. wheel (screwed end) 25 mm dia
| Each | 442.5 | 442.5 | 10.0 | False | None | None | False | None | False | 4425.0 | 0 | 3600488 | 131039 | None | CPWD SR, V-2, P.NO 110,IT.NO 1928 | Brass full way valve with C.I. wheel (screwed end) 32 mm dia
| Each | 489.7 | 489.7 | 5.0 | False | None | None | False | None | False | 2448.5 | 0 | 3600489 | 131039 | None | CPWD SR, V-2, P.NO 111,IT.NO 1929 | Brass full way valve with C.I. wheel (screwed end) 40 mm dia
| Each | 590.0 | 590.0 | 5.0 | False | None | None | False | None | False | 2950.0 | 0 | 3600490 | 131039 | None | CPWD SR, V-2,P.NO 112,IT.NO 1930 | Brass full way valve with C.I. wheel (screwed end) 50 mm dia
| Each | 737.5 | 737.5 | 2.0 | False | None | None | False | None | False | 1475.0 | 0 | 3600491 | 131039 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
| No | 354.35 | 354.35 | 15.0 | False | None | None | False | None | False | 5315.25 | 0 | 3600492 | 131039 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
| No | 11.15 | 11.15 | 2000.0 | False | None | None | False | None | False | 22300.0 | 0 | 3600493 | 131039 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.
100 Liter capacity
| No | 37498.04 | 37498.04 | 2.0 | False | None | None | False | None | False | 74996.08 | 0 | 3600494 | 131039 | None | Market Rate | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards
Ground Toilet
10Cms X 7.5Cms
| No | 371.7 | 371.7 | 45.0 | False | None | None | False | None | False | 16726.5 | 0 | 3600495 | 131039 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
| No | 177.0 | 177.0 | 45.0 | False | None | None | False | None | False | 7965.0 | 0 | 3600496 | 131039 | None | Market Rate | Air Vent Cowel
75mm
| No | 413.0 | 413.0 | 20.0 | False | None | None | False | None | False | 8260.0 | 0 | 3600497 | 131039 | None | Market Rate | Air Vent Cowel
110mm
| No | 590.0 | 590.0 | 20.0 | False | None | None | False | None | False | 11800.0 | 0 | 3600498 | 131039 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. brass pillar taps with C.I. /M.S. brackets, 32 mm C.P. brass waste of standard pattern, including Brass stop cock, 32mm PVC connection painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification as directed by the Engineer in charge. CNS-WHT-705, make Jaguar/hindware/Cera
| No | 5664.0 | 5664.0 | 20.0 | False | None | None | False | None | False | 113280.0 | 0 | 3600499 | 131039 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
| No | 2183.0 | 2183.0 | 8.0 | False | None | None | False | None | False | 17464.0 | 0 | 3600500 | 131039 | None | Market Rate | Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent )
| No | 1996.56 | 1996.56 | 4.0 | False | None | None | False | None | False | 7986.24 | 0 | 3600501 | 131039 | None | Market Rate | Providing and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. | No | 1147.9 | 1147.9 | 10.0 | False | None | None | False | None | False | 11479.0 | 0 | 3600502 | 131039 | None | Market Rate | Providing and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot.
-do- 10cms x 7.5 cms
| Each | 295.0 | 295.0 | 10.0 | False | None | None | False | None | False | 2950.0 | 0 | 3600503 | 131039 | None | Market Rate | Supplying, fixing, testing and commissioning of single sink with large basin for Hospital use.
Pedal-controlled faucet and button-controlled soap dispenser.
The basin is supplied complete with drain, siphon, flexible connection to the water mains and plugs for wall mounting. | No | 25370.0 | 25370.0 | 1.0 | False | None | None | False | None | False | 25370.0 | 0 | 3600504 | 131039 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
| No | 767.0 | 767.0 | 65.0 | False | None | None | False | None | False | 49855.0 | 0 | 3600505 | 131039 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
| No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3600506 | 131039 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
| No | 3304.0 | 3304.0 | 2.0 | False | None | None | False | None | False | 6608.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(EXTERNAL WS & SANITARY) | 1181322.64 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600507 | 131040 | None | V-1,P.NO 6,IT.NO 1.5 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage
& other appurtenances required to complete the work. | Cum | 370.46 | 370.46 | 278.0 | False | None | None | False | None | False | 102987.88 | 0 | 3600508 | 131040 | None | V-1 P.NO 7 IT.NO 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 329.57 | 329.57 | 278.0 | False | None | None | False | None | False | 91620.46 | 0 | 3600509 | 131040 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
- do - 160 mm dia
| Rmtr | 713.66 | 713.66 | 350.0 | False | None | None | False | None | False | 249781.0 | 0 | 3600510 | 131040 | None | V-5,P.NO 134,IT.NO- 10.2.5 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
- do - 200 mm dia
| Rmtr | 1029.61 | 1029.61 | 60.0 | False | None | None | False | None | False | 61776.6 | 0 | 3600511 | 131040 | None | V-5 P.NO 134 IT.NO 10.2.6 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
- do - 250 mm dia
| Rmtr | 1578.49 | 1578.49 | 10.0 | False | None | None | False | None | False | 15784.9 | 0 | 3600512 | 131040 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
| Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3600513 | 131040 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
| No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3600514 | 131040 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
| No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3600515 | 131040 | None | MARKET RATE | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms
| No | 330.4 | 330.4 | 25.0 | False | None | None | False | None | False | 8260.0 | 0 | 3600516 | 131040 | None | IT.NO 11.39 | KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22 m internal dia at bottom, 1.68 m deep and 0.56m dia at top, with table moulded and non modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and down size granite metal and making necessary channel in cement concrete M 15 with 20mm and down size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, total weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4
| No | 36325.0 | 36325.0 | 1.0 | False | None | None | False | None | False | 36325.0 | 0 | 3600517 | 131040 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
| Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3600518 | 131040 | None | Market Rate | Supply and fixing of GM ball cock with copper float(High pressure float)of ISI or BIS Standardsand & fixed on to the inlet pipe at the underground sump tank & OHT.
| No | 5900.0 | 5900.0 | 5.0 | False | None | None | False | None | False | 29500.0 | 0 | 3600519 | 131040 | None | MARKET RATE | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (DOMESTIC)2.00 HP | Nos | 41300.0 | 41300.0 | 2.0 | False | None | None | False | None | False | 82600.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(INETRNAL ELECTRICAL) | 1238058.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600520 | 131041 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
| Point | 333.29 | 333.29 | 36.0 | False | None | None | False | None | False | 11998.44 | 0 | 3600521 | 131041 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
| Pack | 469.58 | 469.58 | 45.0 | False | None | None | False | None | False | 21131.1 | 0 | 3600522 | 131041 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
| Point | 687.65 | 687.65 | 60.0 | False | None | None | False | None | False | 41259.0 | 0 | 3600523 | 131041 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 838.8 | 838.8 | 4.0 | False | None | None | False | None | False | 3355.2 | 0 | 3600524 | 131041 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
| Each | 170.89 | 170.89 | 20.0 | False | None | None | False | None | False | 3417.8 | 0 | 3600525 | 131041 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
| Each | 197.0 | 197.0 | 10.0 | False | None | None | False | None | False | 1970.0 | 0 | 3600526 | 131041 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
| Each | 219.3 | 219.3 | 10.0 | False | None | None | False | None | False | 2193.0 | 0 | 3600527 | 131041 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
| Each | 272.58 | 272.58 | 22.0 | False | None | None | False | None | False | 5996.76 | 0 | 3600528 | 131041 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
| Each | 323.38 | 323.38 | 25.0 | False | None | None | False | None | False | 8084.5 | 0 | 3600529 | 131041 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
| Each | 199.48 | 199.48 | 20.0 | False | None | None | False | None | False | 3989.6 | 0 | 3600530 | 131041 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
| Each | 216.83 | 216.83 | 10.0 | False | None | None | False | None | False | 2168.3 | 0 | 3600531 | 131041 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
| Each | 289.93 | 289.93 | 10.0 | False | None | None | False | None | False | 2899.3 | 0 | 3600532 | 131041 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
| Each | 351.88 | 351.88 | 22.0 | False | None | None | False | None | False | 7741.36 | 0 | 3600533 | 131041 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
| Each | 426.22 | 426.22 | 25.0 | False | None | None | False | None | False | 10655.5 | 0 | 3600534 | 131041 | None | PWD ELE SR V-27 IT.NO 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
| Each | 126.38 | 126.38 | 216.0 | False | None | None | False | None | False | 27298.08 | 0 | 3600535 | 131041 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
| Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3600536 | 131041 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
| Each | 211.87 | 211.87 | 72.0 | False | None | None | False | None | False | 15254.64 | 0 | 3600537 | 131041 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
| Each | 442.32 | 442.32 | 20.0 | False | None | None | False | None | False | 8846.4 | 0 | 3600538 | 131041 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
| Each | 223.02 | 223.02 | 7.0 | False | None | None | False | None | False | 1561.14 | 0 | 3600539 | 131041 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
| Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3600540 | 131041 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
| Each | 292.4 | 292.4 | 22.0 | False | None | None | False | None | False | 6432.8 | 0 | 3600541 | 131041 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
| No | 144.96 | 144.96 | 20.0 | False | None | None | False | None | False | 2899.2 | 0 | 3600542 | 131041 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
| Rmtr | 81.77 | 81.77 | 450.0 | False | None | None | False | None | False | 36796.5 | 0 | 3600543 | 131041 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
| Rmtr | 96.64 | 96.64 | 650.0 | False | None | None | False | None | False | 62816.0 | 0 | 3600544 | 131041 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
| Rmtr | 127.62 | 127.62 | 80.0 | False | None | None | False | None | False | 10209.6 | 0 | 3600545 | 131041 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
| Rmtr | 84.25 | 84.25 | 180.0 | False | None | None | False | None | False | 15165.0 | 0 | 3600546 | 131041 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
| Rmtr | 97.88 | 97.88 | 260.0 | False | None | None | False | None | False | 25448.8 | 0 | 3600547 | 131041 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
| Rmtr | 122.66 | 122.66 | 32.0 | False | None | None | False | None | False | 3925.12 | 0 | 3600548 | 131041 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
| Rmtr | 32.21 | 32.21 | 300.0 | False | None | None | False | None | False | 9663.0 | 0 | 3600549 | 131041 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
| Rmtr | 52.04 | 52.04 | 940.0 | False | None | None | False | None | False | 48917.6 | 0 | 3600550 | 131041 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
| Rmtr | 78.06 | 78.06 | 400.0 | False | None | None | False | None | False | 31224.0 | 0 | 3600551 | 131041 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
| Rmtr | 113.99 | 113.99 | 280.0 | False | None | None | False | None | False | 31917.2 | 0 | 3600552 | 131041 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
| Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3600553 | 131041 | None | PWD ELE SR V-6,IT.NO 5.19.4 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
I- Single Door
12 Way SP & N
| Each | 2308.26 | 2308.26 | 1.0 | False | None | None | False | None | False | 2308.26 | 0 | 3600554 | 131041 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
| Each | 514.19 | 514.19 | 34.0 | False | None | None | False | None | False | 17482.46 | 0 | 3600555 | 131041 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
| Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3600556 | 131041 | None | PWD ELE SR V-6,IT.NO 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps DP
| Each | 915.62 | 915.62 | 1.0 | False | None | None | False | None | False | 915.62 | 0 | 3600557 | 131041 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
| Each | 6538.2 | 6538.2 | 6.0 | False | None | None | False | None | False | 39229.2 | 0 | 3600558 | 131041 | None | PWD ELE SR V-6,IT.NO5.20.2 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
32 -40 Amps 2 pole
| Each | 5648.6 | 5648.6 | 1.0 | False | None | None | False | None | False | 5648.6 | 0 | 3600559 | 131041 | None | PWD ELE SR V-6 BSR-32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
3.5 core 35 sqmm
| Km | 258542.13 | 258542.13 | 0.2 | False | None | None | False | None | False | 51708.426 | 0 | 3600560 | 131041 | None | PWD ELE SR V-6,IT.NO BSR-31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
35 sqmm to 95 sqmm
| Km | 29298.63 | 29298.63 | 0.2 | False | None | None | False | None | False | 5859.726 | 0 | 3600561 | 131041 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
| Each | 144.96 | 144.96 | 8.0 | False | None | None | False | None | False | 1159.68 | 0 | 3600562 | 131041 | None | PWD ELE SR V-6,IT.NO 6.9.2 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.
50mm
| Rmtr | 470.82 | 470.82 | 10.0 | False | None | None | False | None | False | 4708.2 | 0 | 3600563 | 131041 | None | SR 19-20 IT.NO 6.6.2 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)
In soil (hard)
| Rmtr | 126.38 | 126.38 | 90.0 | False | None | None | False | None | False | 11374.2 | 0 | 3600564 | 131041 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
| Each | 39.65 | 39.65 | 8.0 | False | None | None | False | None | False | 317.2 | 0 | 3600565 | 131041 | None | PWD ELE SR V-6,IT.NO 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990.
3CX2.5 Sq mm
| Rmtr | 140.01 | 140.01 | 50.0 | False | None | None | False | None | False | 7000.5 | 0 | 3600566 | 131041 | None | PWD ELE SR V-6 IT.NO2.6.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990.
3CX4 Sq mm
| Rmtr | 206.91 | 206.91 | 100.0 | False | None | None | False | None | False | 20691.0 | 0 | 3600567 | 131041 | None | SR 19-20 IT.NO 6.1 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.
| No | 3716.63 | 3716.63 | 4.0 | False | None | None | False | None | False | 14866.52 | 0 | 3600568 | 131041 | None | SR 19-20 IT.NO 6.3.1 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
| Rmtr | 92.93 | 92.93 | 30.0 | False | None | None | False | None | False | 2787.9 | 0 | 3600569 | 131041 | None | PWD ELE SR V-6,IT.NO 6.3.4 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
50x6mm GI strip
| Rmtr | 241.61 | 241.61 | 20.0 | False | None | None | False | None | False | 4832.2 | 0 | 3600570 | 131041 | None | PWD ELE SR V-6,IT.NO 11.3.2 | Supplying of .feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fighting 1 x4'- 20/22 w | Each | 854.91 | 854.91 | 70.0 | False | None | None | False | None | False | 59843.7 | 0 | 3600571 | 131041 | None | PWD ELE SR V-6,IT.NO 11.6.2 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED modular down light 2'x2' / 1' x 4' 34 -36watt | No | 7307.62 | 7307.62 | 12.0 | False | None | None | False | None | False | 87691.44 | 0 | 3600572 | 131041 | None | PWD ELE SR V-6,IT.NO 11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
7 W, 6500K | No | 184.61 | 184.61 | 8.0 | False | None | None | False | None | False | 1476.88 | 0 | 3600573 | 131041 | None | PWD ELE SR V-6,IT.NO 11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
12 W, 6500K
| No | 333.29 | 333.29 | 13.0 | False | None | None | False | None | False | 4332.77 | 0 | 3600574 | 131041 | None | PWD ELE SR V-6,IT.NO 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply
| No | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3600575 | 131041 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
| Each | 1848.59 | 1848.59 | 10.0 | False | None | None | False | None | False | 18485.9 | 0 | 3600576 | 131041 | None | PWD ELE SR V-6,IT.NO 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.
48" Sweep (1200mm) Regular model
| Each | 3697.18 | 3697.18 | 20.0 | False | None | None | False | None | False | 73943.6 | 0 | 3600577 | 131041 | None | PWD ELE SR V-6,IT.NO 6.5.1 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.
300mm Sweep
| Each | 3087.59 | 3087.59 | 3.0 | False | None | None | False | None | False | 9262.77 | 0 | 3600578 | 131041 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
| Each | 151.16 | 151.16 | 81.0 | False | None | None | False | None | False | 12243.96 | 0 | 3600579 | 131041 | None | PWD ELE SR V-6,IT.NO 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 211.87 | 211.87 | 23.0 | False | None | None | False | None | False | 4873.01 | 0 | 3600580 | 131041 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
| Each | 875.97 | 875.97 | 10.0 | False | None | None | False | None | False | 8759.7 | 0 | 3600581 | 131041 | None | PWD ELE SR V-6,IT.NO 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.
LED Streetlight 25watts | No | 3004.58 | 3004.58 | 4.0 | False | None | None | False | None | False | 12018.32 | 0 | 3600582 | 131041 | None | PWD ELE SR V-6,IT.NO 13.2.2 | Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.
Using 32mm dia G.I.Pipe
| Each | 1604.51 | 1604.51 | 4.0 | False | None | None | False | None | False | 6418.04 | 0 | 3600583 | 131041 | None | PWD ELE SR V-6,IT.NO 13.5 | Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.
Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
| Each | 200.72 | 200.72 | 4.0 | False | None | None | False | None | False | 802.88 | 0 | 3600584 | 131041 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
| Sq CM | 0.53 | 0.53 | 110000.0 | False | None | None | False | None | False | 58300.0 | 0 | 3600585 | 131041 | None | PWD ELE SR V-6,IT.NO 5.40.1 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.
100Amps 4x30x6mm Aluminum Strips
| Rmtr | 3054.14 | 3054.14 | 4.0 | False | None | None | False | None | False | 12216.56 | 0 | 3600586 | 131041 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
| Rmtr | 377.9 | 377.9 | 8.0 | False | None | None | False | None | False | 3023.2 | 0 | 3600587 | 131041 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
| Rmtr | 936.68 | 936.68 | 8.0 | False | None | None | False | None | False | 7493.44 | 0 | 3600588 | 131041 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
| Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3600589 | 131041 | None | PWD ELE SR V-6,IT.NO 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
40Amps TPN
| Each | 3771.52 | 3771.52 | 3.0 | False | None | None | False | None | False | 11314.56 | 0 | 3600590 | 131041 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
| Each | 3826.03 | 3826.03 | 3.0 | False | None | None | False | None | False | 11478.09 | 0 | 3600591 | 131041 | None | PWD ELE SR V-6,IT.NO 5.11.2 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply.
100Amps
| Each | 8784.51 | 8784.51 | 1.0 | False | None | None | False | None | False | 8784.51 | 0 | 3600592 | 131041 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
| Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3600593 | 131041 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
| Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3600594 | 131041 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
| Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3600595 | 131041 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
| Kvar | 594.72 | 594.72 | 10.0 | False | None | None | False | None | False | 5947.2 | 0 | 3600596 | 131041 | None | PWD ELE SR V-6,IT.NO 5.44.1 | Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility.
300mmx300mmx214mm | Each | 5590.37 | 5590.37 | 1.0 | False | None | None | False | None | False | 5590.37 | 0 | 3600597 | 131041 | None | PWD ELE SR V-6,IT.NO 5.35 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.
| Each | 7068.5 | 7068.5 | 1.0 | False | None | None | False | None | False | 7068.5 | 0 | 3600598 | 131041 | None | PWD ELE SR V-6,IT.NO 3.6.12 | TELEPHONE & NETWORKING
RJ45/ I.O. outlet
| Each | 417.54 | 417.54 | 11.0 | False | None | None | False | None | False | 4592.94 | 0 | 3600599 | 131041 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Telephone socket
| Each | 193.28 | 193.28 | 8.0 | False | None | None | False | None | False | 1546.24 | 0 | 3600600 | 131041 | None | PWD ELE SR V-6,IT.NO 8.1 | Supplying and drawing UTP-CAT 6E LAN cable.
| Rmtr | 47.08 | 47.08 | 300.0 | False | None | None | False | None | False | 14124.0 | 0 | 3600601 | 131041 | None | PWD ELE SR V-6,IT.NO 8.10.1 | Supplying & Fixing of I/O Socket with back box Single I/O
| Each | 607.11 | 607.11 | 11.0 | False | None | None | False | None | False | 6678.21 | 0 | 3600602 | 131041 | None | PWD ELE SR V-6,IT.NO 8.4.1 | Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification
4U with 450mm depth
| Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3600603 | 131041 | None | PWD ELE SR V-6,IT.NO 8.9.11 | Supplying fixing of Network Switches.
16 port 10/100/1000 Switch
| Each | 7979.16 | 7979.16 | 1.0 | False | None | None | False | None | False | 7979.16 | 0 | 3600604 | 131041 | None | PWD ELE SR V-6,IT.NO 8.11.1 | Supplying & fixing of .mtrs. Cat 6Patch Cable. 2Mtr
| Each | 318.42 | 318.42 | 11.0 | False | None | None | False | None | False | 3502.62 | 0 | 3600605 | 131041 | None | PWD ELE SR V-6,IT.NO 8.12.3 | Supplying & Fixing of Patch panel for Lan Cabling.
16 Port 10/100 patch panel
| Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3600606 | 131041 | None | PWD ELE SR V-6,IT.NO 8.2.2 | Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable.
| Rmtr | 26.02 | 26.02 | 300.0 | False | None | None | False | None | False | 7806.0 | 0 | 3600607 | 131041 | None | PWD ELE SR V-6,IT.NO 8.13.1 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.
10 Pair
| Each | 427.46 | 427.46 | 1.0 | False | None | None | False | None | False | 427.46 | 0 | 3600608 | 131041 | None | MARKET RATE | TELEPHONES Analog push button telephone with Caller ID, flash and radiaL | No | 1858.5 | 1858.5 | 8.0 | False | None | None | False | None | False | 14868.0 | 0 | 3600609 | 131041 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
| Rmtr | 96.64 | 96.64 | 300.0 | False | None | None | False | None | False | 28992.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(EXTERNAL ELECTRICAL& DG SET) | 1241018.82 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600610 | 131042 | None | BSR- CDS-15 | Supply and fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles)
| Set | 31573.44 | 31573.44 | 1.0 | False | None | None | False | None | False | 31573.44 | 0 | 3600611 | 131042 | None | BSR- CDS-15 | Supply of 11 kV, 45 KN Polymeric Insulator
| No | 250.28 | 250.28 | 6.0 | False | None | None | False | None | False | 1501.68 | 0 | 3600612 | 131042 | None | BSR- CDS-15 | Supply and fixing of Guy Set Complete with No. 15 Strain Insulator & Concreting materials
| Set | 2053.02 | 2053.02 | 2.0 | False | None | None | False | None | False | 4106.04 | 0 | 3600613 | 131042 | None | BSR- CDS-15 | Supply and fixing of Spiral Earth Electrode
| No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 3600614 | 131042 | None | BSR- CDS-15 | Fixing of Guy concreting with Boulders, Mud and Sand
| No | 247.8 | 247.8 | 2.0 | False | None | None | False | None | False | 495.6 | 0 | 3600615 | 131042 | None | BSR- CDS-15 | Supply and fixing of Caution/Danger Board
| No | 256.47 | 256.47 | 1.0 | False | None | None | False | None | False | 256.47 | 0 | 3600616 | 131042 | None | BSR- CDS-15 | Supply and fixing of Anti Climbing Device (12 Mtr GI Barbed Wire
| Each | 154.88 | 154.88 | 2.0 | False | None | None | False | None | False | 309.76 | 0 | 3600617 | 131042 | None | BSR- CDS-15 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
| Set | 26541.86 | 26541.86 | 1.0 | False | None | None | False | None | False | 26541.86 | 0 | 3600618 | 131042 | None | BSR- CDS-15 | Supply and fixing of H-Frame for mounting GOS
| No | 5421.86 | 5421.86 | 1.0 | False | None | None | False | None | False | 5421.86 | 0 | 3600619 | 131042 | None | BSR- CDS-15 | Supply and fixing of DOLO Cut Out
| Set of 3 Nos | 7248.15 | 7248.15 | 1.0 | False | None | None | False | None | False | 7248.15 | 0 | 3600620 | 131042 | None | BSR- 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
| No | 203691.6 | 203691.6 | 1.0 | False | None | None | False | None | False | 203691.6 | 0 | 3600621 | 131042 | None | SR 19-20 6.1 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.
| No | 3716.63 | 3716.63 | 6.0 | False | None | None | False | None | False | 22299.78 | 0 | 3600622 | 131042 | None | SR 19-20-6.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x6mm GI strip
| Rmtr | 142.49 | 142.49 | 60.0 | False | None | None | False | None | False | 8549.4 | 0 | 3600623 | 131042 | None | SR 19-20-6.3.8 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
40x6mm Copper strip
| Rmtr | 1771.77 | 1771.77 | 60.0 | False | None | None | False | None | False | 106306.2 | 0 | 3600624 | 131042 | None | SR 19-20-6.3.10 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600x600x3mm Copper plate
| Each | 8549.1 | 8549.1 | 4.0 | False | None | None | False | None | False | 34196.4 | 0 | 3600625 | 131042 | None | BSR-45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2)
3x95Sqmm.Outdoor
| Set | 4913.87 | 4913.87 | 3.0 | False | None | None | False | None | False | 14741.61 | 0 | 3600626 | 131042 | None | BSR-45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2)
3x95Sqmm.Indoor
| Set | 4523.59 | 4523.59 | 2.0 | False | None | None | False | None | False | 9047.18 | 0 | 3600627 | 131042 | None | BSR-36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975."
95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 1382246.99 | 1382246.99 | 0.03 | False | None | None | False | None | False | 41467.4097 | 0 | 3600628 | 131042 | None | BSR-38 | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. | Sqm | 1222.89 | 1222.89 | 80.0 | False | None | None | False | None | False | 97831.2 | 0 | 3600629 | 131042 | None | BSR-65.04 | Rubber Hand gloves 15 kV, SEAMLESS Confirming to
ISS (Sample to be verified for seamless before approval)
for electrical purpose
| Pair | 1365.38 | 1365.38 | 2.0 | False | None | None | False | None | False | 2730.76 | 0 | 3600630 | 131042 | None | IT.NO 15.122 | Supplying of first aid box. Complete
| Each | 3717.0 | 3717.0 | 2.0 | False | None | None | False | None | False | 7434.0 | 0 | 3600631 | 131042 | None | MARKET RATE | Supplying of FIRST AID CHART with lamination. Complete
| Each | 309.75 | 309.75 | 2.0 | False | None | None | False | None | False | 619.5 | 0 | 3600632 | 131042 | None | IT.NO 5.42.1 | LT KIOSK
Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
| Sq CM | 0.47 | 0.47 | 110000.0 | False | None | None | False | None | False | 51700.0 | 0 | 3600633 | 131042 | None | IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.
250Amps 4x30x10mm Aluminum Strips
| Rmtr | 3813.64 | 3813.64 | 4.0 | False | None | None | False | None | False | 15254.56 | 0 | 3600634 | 131042 | None | IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
| Rmtr | 340.73 | 340.73 | 8.0 | False | None | None | False | None | False | 2725.84 | 0 | 3600635 | 131042 | None | IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
| Rmtr | 842.52 | 842.52 | 8.0 | False | None | None | False | None | False | 6740.16 | 0 | 3600636 | 131042 | None | IT.NO 5.14 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
FOUR POLE
125Amps 25kA
| Each | 12479.21 | 12479.21 | 2.0 | False | None | None | False | None | False | 24958.42 | 0 | 3600637 | 131042 | None | IT.NO 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps DP
| Each | 1366.62 | 1366.62 | 4.0 | False | None | None | False | None | False | 5466.48 | 0 | 3600638 | 131042 | None | IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
| Each | 574.9 | 574.9 | 3.0 | False | None | None | False | None | False | 1724.7 | 0 | 3600639 | 131042 | None | 10.1.1 | Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class HMounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibr 15KVA/12kw | Set | 432547.3 | 432547.3 | 1.0 | False | None | None | False | None | False | 432547.3 | 0 | 3600640 | 131042 | None | 10.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility.15KVA | Each | 72743.46 | 72743.46 | 1.0 | False | None | None | False | None | False | 72743.46 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(SEPTIC TANK & SOAK PIT)) | 477864.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600641 | 131043 | None | PWD SR 2023-24 V- III Page No-9 It No-2.5(ii) A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.168 | False | None | None | False | None | False | 81.80256 | 0 | 3600642 | 131043 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 126.37 | 126.37 | 42.072 | False | None | None | False | None | False | 5316.63864 | 0 | 3600643 | 131043 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 1.16 | False | None | None | False | None | False | 8607.6292 | 0 | 3600644 | 131043 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8028.72 | 8028.72 | 10.609 | False | None | None | False | None | False | 85176.69048 | 0 | 3600645 | 131043 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum) Earth retaining structures | Cum | 802.87 | 802.87 | 7.47 | False | None | None | False | None | False | 5997.4389 | 0 | 3600646 | 131043 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115)
( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) | Cum | 4014.36 | 4014.36 | 3.142 | False | None | None | False | None | False | 12613.11912 | 0 | 3600647 | 131043 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) | t | 110837.22 | 110837.22 | 1.78 | False | None | None | False | None | False | 197290.2516 | 0 | 3600648 | 131043 | None | Old SR 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 15.0 | False | None | None | False | None | False | 5631.15 | 0 | 3600649 | 131043 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 53.41 | False | None | None | False | None | False | 40035.6019 | 0 | 3600650 | 131043 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 432.41 | 432.41 | 53.41 | False | None | None | False | None | False | 23095.0181 | 0 | 3600651 | 131043 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized | No. | 16284.0 | 16284.0 | 3.0 | False | None | None | False | None | False | 48852.0 | 0 | 3600652 | 131043 | None | PWD SR 2023-24 V-2 Page No-176 It No-17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains &
Rain pit of width not exceeding 800 mm using M20 concrete reinforced
with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00
kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including
providing holes in the Cover slabs wherever necessary for easy
drainage of surface water including of labour, materials, scaffolding,
usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1149.79 | 1149.79 | 6.37 | False | None | None | False | None | False | 7324.1623 | 0 | 3600653 | 131043 | None | PWD SR 2023-24 V-2 Page No-13 It No-6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 10471.32 | 10471.32 | 1.6 | False | None | None | False | None | False | 16754.112 | 0 | 3600654 | 131043 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.47 | 1241.47 | 5.6 | False | None | None | False | None | False | 6952.232 | 0 | 3600655 | 131043 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.2 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.45 | 1469.45 | 5.6 | False | None | None | False | None | False | 8228.92 | 0 | 3600656 | 131043 | None | PWD SR 2023-24 V-1I Page No-175 It No-17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.88 | 1476.88 | 4.0 | False | None | None | False | None | False | 5907.52 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(SUMP TANK) | 326860.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600657 | 131044 | None | PWD SR 2023-24 V- III Page No-7 It No-2.5(ii)A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
By Mechanical Means using Dozer In area of light jungle | 100 Sqm | 486.92 | 486.92 | 0.185 | False | None | None | False | None | False | 90.0802 | 0 | 3600658 | 131044 | None | PWD SR 2023-24 V- 1 Page No-8 It No-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 126.37 | 126.37 | 23.887 | False | None | None | False | None | False | 3018.60019 | 0 | 3600659 | 131044 | None | PWD SR 2023-24 V- 1 Page No-15 It No-2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 2.385 | False | None | None | False | None | False | 17697.58245 | 0 | 3600660 | 131044 | None | PWD SR 2023-24 V- 1 Page No-16 It No-2.3.2 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8028.72 | 8028.72 | 10.695 | False | None | None | False | None | False | 85867.1604 | 0 | 3600661 | 131044 | None | PWD SR 2023-24 V-1 Page No-116 It No-5 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Earth retaining structures | Cum | 802.87 | 802.87 | 4.375 | False | None | None | False | None | False | 3512.55625 | 0 | 3600662 | 131044 | None | PWD SR 2023-24 V-1 Page No-112 It No-15 | Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum)
Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete Quantity | Cum | 4014.36 | 4014.36 | 6.32 | False | None | None | False | None | False | 25370.7552 | 0 | 3600663 | 131044 | None | PWD SR 2023-24 V-1 Page No-18 It No-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slab | t | 110837.22 | 110837.22 | 1.09 | False | None | None | False | None | False | 120812.5698 | 0 | 3600664 | 131044 | None | Old Sr 2018-19 It No-11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 | Nos | 375.41 | 375.41 | 3.0 | False | None | None | False | None | False | 1126.23 | 0 | 3600665 | 131044 | None | Approved Rate | Supplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm dia | Nos | 16284.0 | 16284.0 | 1.0 | False | None | None | False | None | False | 16284.0 | 0 | 3600666 | 131044 | None | PWD SR 2023-24 V-II Page No-150 It No-15.5 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 749.59 | 749.59 | 44.6 | False | None | None | False | None | False | 33431.714 | 0 | 3600667 | 131044 | None | PWD SR 2023-24 V-2 Page No-42 It No-8.6.1 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge. | Sqm | 400.19 | 400.19 | 49.1 | False | None | None | False | None | False | 19649.329 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(UPS) | 415116.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600668 | 131045 | None | PWD SR 2023-24 Volume 6 It No-9.3.5 | Supplying, erecting, testing & commissioning of ON-LINE UPS
system suitable for operation on 230V, 50Hz, A/C supply,
with isolation transformer all accessories complete and
Excluding batteries and wiring complete. 10 kVA ON LINE UPS | Each | 122212.6 | 122212.6 | 1.0 | False | None | None | False | None | False | 122212.6 | 0 | 3600669 | 131045 | None | PWD SR 2023-24 Volume 6 It No-9.5.8 | Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacity | Each | 18306.52 | 18306.52 | 16.0 | False | None | None | False | None | False | 292904.32 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(ACs) | 122781.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600670 | 131046 | None | 6.8.2 | Supplyingof .TRInvertor type splitAirconditionerssuitable
foroperation onA/Csupply singlephase50Hz230Vwith
hermetically sealed inverter compressor with air cooled
condenser, latestR410A/R-32refrigerant fanmotor,start&
runcapacitors, relay&overloadprotector internal unit,with
one indoor&one outdoor unit The condenser unit will be
placedoutsidetheroomavoidnoiseincluding standardlength
of suitable size copper tubing covered with nitrile rubber
insulation tube. suitable capacity 3 core sheathed/ PVC
copper cable and a battery operated wireless remote unit.
3 star - 1.5 Ton capacity | Each | 53435.12 | 53435.12 | 2.0 | False | None | None | False | None | False | 106870.24 | 0 | 3600671 | 131046 | None | 6.10 | Installation charges for split type air conditioner with allied worksforoneindoorandoneoutdoorunit istobemountedon suitableAngle Iron support upto3.0Tonsplit/cassette type
A/C. | Each | 3746.5 | 3746.5 | 2.0 | False | None | None | False | None | False | 7493.0 | 0 | 3600672 | 131046 | None | 9.1.1 | Supplying, erecting, testing and commissioning of voltage
stabilizersuitablefor170to270vinputandloadvariationfrom
no load to full load, with over load protection, spike
suppression, operating at 00 C to 400 C. Range etc.,
complete - 3kVA Capacity | Each | 4209.06 | 4209.06 | 2.0 | False | None | None | False | None | False | 8418.12 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(street lighting system) | 318859.01 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600673 | 131047 | None | PWD SR 2023-24 Volume 6 It No-4.4.5 | Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm dia | Each | 17700.0 | 17700.0 | 4.0 | False | None | None | False | None | False | 70800.0 | 0 | 3600674 | 131047 | None | PWD SR 2023-24 Volume 6 It No-4.6.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2006.0 | 2006.0 | 4.0 | False | None | None | False | None | False | 8024.0 | 0 | 3600675 | 131047 | None | PWD SR 2023-24 Volume 6 It No-11.8.3 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70watts | Each | 7070.56 | 7070.56 | 4.0 | False | None | None | False | None | False | 28282.24 | 0 | 3600676 | 131047 | None | PWD SR 2023-24 Volume 6 It No-13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 4.0 | False | None | None | False | None | False | 764.64 | 0 | 3600677 | 131047 | None | PWD SR 2023-24 Volume 6 It No-32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 139244.72 | 139244.72 | 0.15 | False | None | None | False | None | False | 20886.708 | 0 | 3600678 | 131047 | None | PWD SR 2023-24 Volume 6 It No-21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.15 | False | None | None | False | None | False | 3696.822 | 0 | 3600679 | 131047 | None | PWD SR 2023-24 Volume 6 It No-2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmm | m | 133.34 | 133.34 | 210.0 | False | None | None | False | None | False | 28001.4 | 0 | 3600680 | 131047 | None | PWD SR 2023-24 Volume 6 It No-2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmm | m | 202.96 | 202.96 | 150.0 | False | None | None | False | None | False | 30444.0 | 0 | 3600681 | 131047 | None | MR 1 | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM ID | m | 300.9 | 300.9 | 20.0 | False | None | None | False | None | False | 6018.0 | 0 | 3600682 | 131047 | None | PWD SR 2023-24 Volume 6 It No-6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 ) | m | 89.68 | 89.68 | 150.0 | False | None | None | False | None | False | 13452.0 | 0 | 3600683 | 131047 | None | PWD SR 2023-24 Volume 6 It No-6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 ) | m | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | 3600684 | 131047 | None | PWD SR 2023-24 Volume 6 It No-11.9.1 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 7986.24 | 7986.24 | 6.0 | False | None | None | False | None | False | 47917.44 | 0 | 3600685 | 131047 | None | PWD SR 2023-24 Volume 6 It No-11.7.2 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 Watts | Each | 9111.96 | 9111.96 | 6.0 | False | None | None | False | None | False | 54671.76 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(CC Road) | 821594.59 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600686 | 131048 | None | PWD SR 2023-24 V-3 Page No-9 It No-2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle | 100 Sqm | 486.92 | 486.92 | 3.6 | False | None | None | False | None | False | 1752.912 | 0 | 3600687 | 131048 | None | PWD SR 2023-24 V-1 Page No-8 It No-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 117.7 | 117.7 | 108.0 | False | None | None | False | None | False | 12711.6 | 0 | 3600688 | 131048 | None | PWD SR 2023-24 V-3 Page No-17 It No-305.3.4 | Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 130.09 | 130.09 | 108.0 | False | None | None | False | None | False | 14049.72 | 0 | 3600689 | 131048 | None | PWD SR 2023-24 VI Page No-7 It No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 587.28 | 587.28 | 108.0 | False | None | None | False | None | False | 63426.24 | 0 | 3600690 | 131048 | None | PWD SR 2023-24 V-3 Page No-23 It No-4.2(v) | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 2922.8 | 2922.8 | 36.0 | False | None | None | False | None | False | 105220.8 | 0 | 3600691 | 131048 | None | CSR 2023-24 Vol-3,P. No. 26,It. No. 4.17 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 3170.6 | 3170.6 | 54.0 | False | None | None | False | None | False | 171212.4 | 0 | 3600692 | 131048 | None | PWDSR2023-24 V-3 Page No-51 It No-6.6 | Construction of un-reinforced plain cement concrete pavementusing RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedureand thickness as per design, over a prepared sub base. Thesuperplastisiser confirming to IS 9103-1999 Reaffirmed-2008,Coarse aggregates and Fine aggregate confirming to IS:383-2016,transported to site, laid in approved fixed side form work (steelchannel, laying and fixing of 125 micron thick polythene film,wedges, steel plates including levelling the form work). Spreadingthe concrete with shovels, rackers and compacted using needle,suitable plate vibrator and finished in a continuous operation Including provision of separation membrane and Hessian clothfinishing to lines and grades complete including cost of all
materials, labour, all lead & lift, loading charges as per specification& direction of Engineer incharge of the work | Cum | 8392.98 | 8392.98 | 54.0 | False | None | None | False | None | False | 453220.92 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(Compound wall) | 3658914.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600693 | 131049 | None | 1.5 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 370.46 | 370.46 | 194.87 | False | None | None | False | None | False | 72191.5402 | 0 | 3600694 | 131049 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7420.37 | 7420.37 | 43.06 | False | None | None | False | None | False | 319521.1322 | 0 | 3600695 | 131049 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenance | Cum | 8412.76 | 8412.76 | 24.3 | False | None | None | False | None | False | 204430.068 | 0 | 3600696 | 131049 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. | Cum | 13242.31 | 13242.31 | 44.5 | False | None | None | False | None | False | 589282.795 | 0 | 3600697 | 131049 | None | 2.11A | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 110837.22 | 110837.22 | 8.36 | False | None | None | False | None | False | 926599.1592 | 0 | 3600698 | 131049 | None | 6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 9873.59 | 9873.59 | 74.87 | False | None | None | False | None | False | 739235.6833 | 0 | 3600699 | 131049 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 459.67 | 459.67 | 1144.03 | False | None | None | False | None | False | 525876.2701 | 0 | 3600700 | 131049 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Set of 2 Nos | 193.28 | 193.28 | 1144.03 | False | None | None | False | None | False | 221118.1184 | 0 | 3600701 | 131049 | None | PWD Volume- 2 SR 2023-24 Page No-84 It No-11.25. | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kg | 168.5 | 168.5 | 360.0 | False | None | None | False | None | False | 60660.0 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(Borewell) | 419515.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600702 | 131050 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3600703 | 131050 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3600704 | 131050 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
| Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3600705 | 131050 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
| Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3600706 | 131050 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Rmtr | 2394.99 | 2394.99 | 25.0 | False | None | None | False | None | False | 59874.75 | 0 | 3600707 | 131050 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | Rmtr | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3600708 | 131050 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3600709 | 131050 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3600710 | 131050 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3600711 | 131050 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
| Each | 34832.01 | 34832.01 | 1.0 | False | None | None | False | None | False | 34832.01 | 0 | 3600712 | 131050 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3600713 | 131050 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3600714 | 131050 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3600715 | 131050 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3600716 | 131050 | None | V-5P156I13.34 | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. | Job | 1796.55 | 1796.55 | 1.0 | False | None | None | False | None | False | 1796.55 | 0 | 3600717 | 131050 | None | EleSrP No 12 2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10) | Rmtr | 121.42 | 121.42 | 259.0 | False | None | None | False | None | False | 31447.78 | 0 | 3600718 | 131050 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
| Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3600719 | 131050 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
| Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3600720 | 131050 | None | Ele SrP No 44,I No 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge | Each | 361.79 | 361.79 | 1.0 | False | None | None | False | None | False | 361.79 | 0 | 3600721 | 131050 | None | Ele rP No 47No 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral | Each | 2124.89 | 2124.89 | 1.0 | False | None | None | False | None | False | 2124.89 | 0 | 3600722 | 131050 | None | Ele SP No 44,INo 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge | Each | 2230.29 | 2230.29 | 1.0 | False | None | None | False | None | False | 2230.29 | 0 | 3600723 | 131050 | None | EleSr No 48,I No.6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35) | Each | 495.6 | 495.6 | 1.0 | False | None | None | False | None | False | 495.6 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC(RWH) | 53000.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600724 | 131051 | None | V-1page5itm1.4. | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 299.84 | 299.84 | 6.79 | False | None | None | False | None | False | 2035.9136 | 0 | 3600725 | 131051 | None | V-1PAGE5ITM1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 320.9 | 320.9 | 6.79 | False | None | None | False | None | False | 2178.911 | 0 | 3600726 | 131051 | None | V-2P175I17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. | Each | 1391.4 | 1391.4 | 28.0 | False | None | None | False | None | False | 38959.2 | 0 | 3600727 | 131051 | None | V-2P175I17.1 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1241.5 | 1241.5 | 1.13 | False | None | None | False | None | False | 1402.895 | 0 | 3600728 | 131051 | None | V-2P175I17.2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1469.5 | 1469.5 | 0.57 | False | None | None | False | None | False | 837.615 | 0 | 3600729 | 131051 | None | V-2P175I17.3 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. | Cum | 1476.9 | 1476.9 | 0.57 | False | None | None | False | None | False | 841.833 | 0 | 3600730 | 131051 | None | V-2P175I17.4 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. | Cum | 1659.0 | 1659.0 | 0.57 | False | None | None | False | None | False | 945.63 | 0 | 3600731 | 131051 | None | V-2P177I17.14 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1449.6 | 1449.6 | 4.0 | False | None | None | False | None | False | 5798.4 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC NURSE QTRS (Civil Works) | 3682939.99 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600732 | 131052 | None | V-3 P.NO 7 IT.NO 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle
| Sqm | 486.92 | 486.92 | 300.0 | False | None | None | False | None | False | 146076.0 | 0 | 3600733 | 131052 | None | V-1 P.NO 8 IT.NO 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
| Cum | 117.71 | 117.71 | 90.0 | False | None | None | False | None | False | 10593.9 | 0 | 3600734 | 131052 | None | V-1 p.NO 8 IT.NO 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 126.38 | 126.38 | 61.03 | False | None | None | False | None | False | 7712.9714 | 0 | 3600735 | 131052 | None | V-1 p.no 8 IT.NO 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
| Cum | 449.76 | 449.76 | 26.15 | False | None | None | False | None | False | 11761.224 | 0 | 3600736 | 131052 | None | V-3 P.NO 3 IT.NO A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)
| Cum | 167.27 | 167.27 | 56.15 | False | None | None | False | None | False | 9392.2105 | 0 | 3600737 | 131052 | None | V-2 P.NO 5 IT.NO 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| Sqm | 146.21 | 146.21 | 139.0 | False | None | None | False | None | False | 20323.19 | 0 | 3600738 | 131052 | None | V-1 P.NO 7 IT.NO 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 329.58 | 329.58 | 61.03 | False | None | None | False | None | False | 20114.2674 | 0 | 3600739 | 131052 | None | V-1 P.NO 7 IT.NO 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 587.29 | 587.29 | 60.8 | False | None | None | False | None | False | 35707.232 | 0 | 3600740 | 131052 | None | V-1 P.NO 15 IT.NO 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 7420.38 | 7420.38 | 25.88 | False | None | None | False | None | False | 192039.4344 | 0 | 3600741 | 131052 | None | V-1 P.NO 15 IT.NO 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 8412.77 | 8412.77 | 11.1 | False | None | None | False | None | False | 93381.747 | 0 | 3600742 | 131052 | None | V-1 P.NO 15 IT.NO 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
PEDESTAL
| Cum | 8568.56 | 8568.56 | 11.77 | False | None | None | False | None | False | 100851.9512 | 0 | 3600743 | 131052 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 14413.42 | 14413.42 | 9.06 | False | None | None | False | None | False | 130585.5852 | 0 | 3600744 | 131052 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
PLINTH BEAM
| Cum | 12717.72 | 12717.72 | 6.15 | False | None | None | False | None | False | 78213.978 | 0 | 3600745 | 131052 | None | V-1 P.N 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
STAIRCASE
GROUND FLOOR
| Cum | 12293.8 | 12293.8 | 2.38 | False | None | None | False | None | False | 29259.244 | 0 | 3600746 | 131052 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
ROOF BEAMS
GROUND FLOOR
| Cum | 13565.57 | 13565.57 | 5.42 | False | None | None | False | None | False | 73525.3894 | 0 | 3600747 | 131052 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
ROOF SLAB
GROUND FLOOR
| Cum | 12717.72 | 12717.72 | 14.11 | False | None | None | False | None | False | 179447.0292 | 0 | 3600748 | 131052 | None | V-1 P.NO 17 IT.NO 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
LINTELS
GROUND FLOOR
| Cum | 13565.57 | 13565.57 | 1.67 | False | None | None | False | None | False | 22654.5019 | 0 | 3600749 | 131052 | None | V-1 P.NO 15 IT.NO 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 11169.16 | 11169.16 | 1.27 | False | None | None | False | None | False | 14184.8332 | 0 | 3600750 | 131052 | None | V-3 P.NO 117 IT.NO 15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
| No | 252.76 | 252.76 | 4.0 | False | None | None | False | None | False | 1011.04 | 0 | 3600751 | 131052 | None | V-2 P.NO 9 IT.NO 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 7915.98 | 7915.98 | 1.33 | False | None | None | False | None | False | 10528.2534 | 0 | 3600752 | 131052 | None | V-1 P.NO 18 IT.NO 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
| t | 110837.23 | 110837.23 | 6.15 | False | None | None | False | None | False | 681648.9645 | 0 | 3600753 | 131052 | None | sr-18-19 P.NO14 IT.NO 4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
| Rmtr | 38.94 | 38.94 | 26.22 | False | None | None | False | None | False | 1021.0068 | 0 | 3600754 | 131052 | None | Data Rate | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.
| Rmtr | 86.14 | 86.14 | 26.22 | False | None | None | False | None | False | 2258.5908 | 0 | 3600755 | 131052 | None | V-2 P.NO 14 IT.NO 6.32 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 9873.6 | 9873.6 | 40.15 | False | None | None | False | None | False | 396425.04 | 0 | 3600756 | 131052 | None | V-2 P.NO 14 IT.NO 6.13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1209.27 | 1209.27 | 32.25 | False | None | None | False | None | False | 38998.9575 | 0 | 3600757 | 131052 | None | V-2 P.NO 100 IT.NO 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 122431.79 | 122431.79 | 0.19 | False | None | None | False | None | False | 23262.0401 | 0 | 3600758 | 131052 | None | V-2 P.NO 105 IT.NO 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1258.83 | 1258.83 | 4.0 | False | None | None | False | None | False | 5035.32 | 0 | 3600759 | 131052 | None | V-2 P.NO 107 IT.NO 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1303.43 | 1303.43 | 4.0 | False | None | None | False | None | False | 5213.72 | 0 | 3600760 | 131052 | None | V-2 P.NO 107 IT.NO 12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
| No | 1226.61 | 1226.61 | 4.0 | False | None | None | False | None | False | 4906.44 | 0 | 3600761 | 131052 | None | V-2 P.NO 107 IT.NO 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with
necessary screws etc. complete"
| No | 293.65 | 293.65 | 4.0 | False | None | None | False | None | False | 1174.6 | 0 | 3600762 | 131052 | None | V-2 P.NO 107 IT.NO 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
| No | 161.07 | 161.07 | 4.0 | False | None | None | False | None | False | 644.28 | 0 | 3600763 | 131052 | None | V-2 P.NO 107 IT.NO 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms
| No | 68.15 | 68.15 | 4.0 | False | None | None | False | None | False | 272.6 | 0 | 3600764 | 131052 | None | V-2 P.NO 108 IT.NO 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)
| No | 340.73 | 340.73 | 4.0 | False | None | None | False | None | False | 1362.92 | 0 | 3600765 | 131052 | None | V-2 P.NO 69 IT.NO 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 74.34 | 74.34 | 24.0 | False | None | None | False | None | False | 1784.16 | 0 | 3600766 | 131052 | None | XI, 18-19 SR, 309 (0115) | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.
| Rmtr | 15.0 | 15.0 | 19.35 | False | None | None | False | None | False | 290.25 | 0 | 3600767 | 131052 | None | V-2 P.NO 106 IT.NO 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial
| Sqm | 4115.96 | 4115.96 | 7.88 | False | None | None | False | None | False | 32433.7648 | 0 | 3600768 | 131052 | None | V-2 (CPWD) P.NO 542 IT.NO 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick
| Sqm | 4317.92 | 4317.92 | 3.15 | False | None | None | False | None | False | 13601.448 | 0 | 3600769 | 131052 | None | V-2 (CPWD) P.NO 541 IT.NO 26.86.2 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).26.86.2 Frame size 45 x 85 mm
| Rmtr | 869.78 | 869.78 | 9.9 | False | None | None | False | None | False | 8610.822 | 0 | 3600770 | 131052 | None | V-2 P.NO 109 IT.NO 12.87 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 8116.69 | 8116.69 | 11.34 | False | None | None | False | None | False | 92043.2646 | 0 | 3600771 | 131052 | None | V-2 P.NO 109 IT.NO 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7085.85 | 7085.85 | 1.08 | False | None | None | False | None | False | 7652.718 | 0 | 3600772 | 131052 | None | V-2 P.NO 110 IT.NO 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 208.16 | 208.16 | 215.41 | False | None | None | False | None | False | 44839.7456 | 0 | 3600773 | 131052 | None | V-2 P.NO 81 IT.NO 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
FOR WATER TANK STAND
| Kg | 182.14 | 182.14 | 102.75 | False | None | None | False | None | False | 18714.885 | 0 | 3600774 | 131052 | None | V-2 P.NO 41 IT.NO 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 386.57 | 386.57 | 434.01 | False | None | None | False | None | False | 167775.2457 | 0 | 3600775 | 131052 | None | V-2 P.NO 43 IT.NO 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 261.43 | 261.43 | 49.3 | False | None | None | False | None | False | 12888.499 | 0 | 3600776 | 131052 | None | V-2 P.NO 50 IT.NO 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 123.9 | 123.9 | 483.31 | False | None | None | False | None | False | 59882.109 | 0 | 3600777 | 131052 | None | V-2 P.NO 41 IT.NO 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Outside)
| Sqm | 432.42 | 432.42 | 218.46 | False | None | None | False | None | False | 94466.4732 | 0 | 3600778 | 131052 | None | V-2 P.NO 42 IT.NO 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 438.61 | 438.61 | 14.02 | False | None | None | False | None | False | 6149.3122 | 0 | 3600779 | 131052 | None | P.NO118,18-19 SR ,IT.NO 15.36 | KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )
| Rmtr | 38.78 | 38.78 | 301.69 | False | None | None | False | None | False | 11699.5382 | 0 | 3600780 | 131052 | None | P.NO 70,18-19 SR,IT.NO 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.
| Sqm | 270.18 | 270.18 | 5.0 | False | None | None | False | None | False | 1350.9 | 0 | 3600781 | 131052 | None | V-2 P.NO 54 IT.NO 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 64.43 | 64.43 | 166.05 | False | None | None | False | None | False | 10698.6015 | 0 | 3600782 | 131052 | None | V-2 P.NO 61 IT.NO 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm
| Sqm | 1455.83 | 1455.83 | 47.9 | False | None | None | False | None | False | 69734.257 | 0 | 3600783 | 131052 | None | V-2 P.NO 63 IT.NO 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent.
| Sqm | 3055.38 | 3055.38 | 26.68 | False | None | None | False | None | False | 81517.5384 | 0 | 3600784 | 131052 | None | V-2,P.NO 65,IT.NO 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.
| Sqm | 2044.35 | 2044.35 | 5.46 | False | None | None | False | None | False | 11162.151 | 0 | 3600785 | 131052 | None | V-2,P.NO 41,IT.NO 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 365.51 | 365.51 | 40.97 | False | None | None | False | None | False | 14974.9447 | 0 | 3600786 | 131052 | None | V-2,P.NO 60,IT.NO 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 1101.48 | 1101.48 | 7.3 | False | None | None | False | None | False | 8040.804 | 0 | 3600787 | 131052 | None | V-2 P.NO 65 IT.NO 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1795.32 | 1795.32 | 40.97 | False | None | None | False | None | False | 73554.2604 | 0 | 3600788 | 131052 | None | V-2 P.NO 83 IT.NO 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 700.04 | 700.04 | 337.83 | False | None | None | False | None | False | 236494.5132 | 0 | 3600789 | 131052 | None | V-2 P.NO 48 IT.NO 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 157.36 | 157.36 | 483.31 | False | None | None | False | None | False | 76053.6616 | 0 | 3600790 | 131052 | None | V-2 P.NO 45 IT.NO 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 193.29 | 193.29 | 196.61 | False | None | None | False | None | False | 38002.7469 | 0 | 3600791 | 131052 | None | V-2 P.NO 45 IT.NO 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
| Sqm | 350.64 | 350.64 | 21.85 | False | None | None | False | None | False | 7661.484 | 0 | 3600792 | 131052 | None | V-2 P.NO 47 IT.NO 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 61.95 | 61.95 | 6.21 | False | None | None | False | None | False | 384.7095 | 0 | 3600793 | 131052 | None | V-2 P.NO 48 IT.NO 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 142.49 | 142.49 | 6.21 | False | None | None | False | None | False | 884.8629 | 0 | 3600794 | 131052 | None | V-2 P.NO 47 IT.NO 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 65.67 | 65.67 | 18.9 | False | None | None | False | None | False | 1241.163 | 0 | 3600795 | 131052 | None | V-2 P.NO 46 IT.NO 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade.Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brandandmanufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeas per specifications and as per directions of Engineer-in-charge.
| Sqm | 170.99 | 170.99 | 18.9 | False | None | None | False | None | False | 3231.711 | 0 | 3600796 | 131052 | None | V-2 P.NO 75 IT.NO 11.5.1 | Providing and fixing 1mm thick M.S.steel garage door with frame and diagonal braces of size 40x40x6 mm angle Iron 3.15mm thick M.S.Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications.
| Sqm | 5548.25 | 5548.25 | 2.1 | False | None | None | False | None | False | 11651.325 | 0 | 3600797 | 131052 | None | data rate | Providing & laying Screed Concreete using 12mm & down size graded granite/trap metal,average thickness of 7.50cms including finishing etc complete as per specification with all lead & lift as directed by Engineer incharge.(Data Rate) - With all lead and lifts etc., complete as per specification and as per the directions of the Engineer-In-Charge of the work.
| Sqm | 585.28 | 585.28 | 139.0 | False | None | None | False | None | False | 81353.92 | 0 | 3600798 | 131052 | None | V-2 P.NO 26 IT.NO 7.38 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard
film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 703.76 | 703.76 | 8.4 | False | None | None | False | None | False | 5911.584 | 0 | 3600799 | 131052 | None | V-5 P.NO 34 IT.NO 3713 | PVC pipes of 6 Kg/cm2 for 110mm(1.894)
| Rmtr | 443.57 | 443.57 | 60.0 | False | None | None | False | None | False | 26614.2 | 0 |
| 1721809517000 | 0 | None | None | Buildings | HEMALAPUR PHC NUSE QTRS (Internal WS AND SANITARY) | 276216.78 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600800 | 131053 | None | V-2 P.NO 28 IT.NO 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
40mm dia pipes, From wash basin waste lines
| Rmtr | 113.99 | 113.99 | 10.0 | False | None | None | False | None | False | 1139.9 | 0 | 3600801 | 131053 | None | V-5 P.NO 187 IT.NO T090 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:
50mm nominal bore pipes, From Sink & Urinal lines
| Rmtr | 213.38 | 213.38 | 10.0 | False | None | None | False | None | False | 2133.8 | 0 | 3600802 | 131053 | None | V-5 P.NO 34 IT.NO 3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines
| Rmtr | 337.73 | 337.73 | 40.0 | False | None | None | False | None | False | 13509.2 | 0 | 3600803 | 131053 | None | V-5 P.NO 34 IT.NO 3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines
| Rmtr | 630.94 | 630.94 | 35.0 | False | None | None | False | None | False | 22082.9 | 0 | 3600804 | 131053 | None | V-2 P.NO 119 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
| Rmtr | 244.08 | 244.08 | 15.0 | False | None | None | False | None | False | 3661.2 | 0 | 3600805 | 131053 | None | V-2 P.NO 119 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
| Rmtr | 360.55 | 360.55 | 10.0 | False | None | None | False | None | False | 3605.5 | 0 | 3600806 | 131053 | None | V-5 P.NO 34 IT.NO 3711 | PVC pipe - OD 75mm and 6 Kg/sqcm - (Shaft Drainage)
| Rmtr | 337.01 | 337.01 | 20.0 | False | None | None | False | None | False | 6740.2 | 0 | 3600807 | 131053 | None | V-5 P.NO 34 IT.NO 3713 | PVC pipe - OD 110mm and 6 Kg/sqcm - (Shaft Drainage)
| Rmtr | 630.94 | 630.94 | 20.0 | False | None | None | False | None | False | 12618.8 | 0 | 3600808 | 131053 | None | V-2 P.NO 128 IT.NO 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| No | 1511.58 | 1511.58 | 2.0 | False | None | None | False | None | False | 3023.16 | 0 | 3600809 | 131053 | None | V-2 P.NO 116 IT.NO 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
| No | 345.68 | 345.68 | 1.0 | False | None | None | False | None | False | 345.68 | 0 | 3600810 | 131053 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
| No | 6891.32 | 6891.32 | 1.0 | False | None | None | False | None | False | 6891.32 | 0 | 3600811 | 131053 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| No | 614.54 | 614.54 | 1.0 | False | None | None | False | None | False | 614.54 | 0 | 3600812 | 131053 | None | V-2 P.NO 123 IT.NO 14.3 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and
mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good
the walls and floors wherever required
| No | 7192.4 | 7192.4 | 1.0 | False | None | None | False | None | False | 7192.4 | 0 | 3600813 | 131053 | None | V-2 P.NO 126 IT.NO14.10.1.4 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm
| No | 5986.85 | 5986.85 | 2.0 | False | None | None | False | None | False | 11973.7 | 0 | 3600814 | 131053 | None | V-2 P.NO A-14 IT.NO 91 | C.P. Brass stop cock (concealed) 15 mm
| No | 650.48 | 650.48 | 2.0 | False | None | None | False | None | False | 1300.96 | 0 | 3600815 | 131053 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
| No | 3818.6 | 3818.6 | 1.0 | False | None | None | False | None | False | 3818.6 | 0 | 3600816 | 131053 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm dia
| Rmtr | 382.85 | 382.85 | 20.0 | False | None | None | False | None | False | 7657.0 | 0 | 3600817 | 131053 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
GROUND FLOOR
20 mm dia
| Rmtr | 469.58 | 469.58 | 20.0 | False | None | None | False | None | False | 9391.6 | 0 | 3600818 | 131053 | None | V-2 P.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
GROUND FLOOR
25 mm dia
| Rmtr | 591.0 | 591.0 | 25.0 | False | None | None | False | None | False | 14775.0 | 0 | 3600819 | 131053 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
32 mm dia
| Rmtr | 690.12 | 690.12 | 10.0 | False | None | None | False | None | False | 6901.2 | 0 | 3600820 | 131053 | None | V-2 P.NO 120 IT.NO 13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)"
External & Shafts & Terrace
40mm DWS
| Rmtr | 591.0 | 591.0 | 45.0 | False | None | None | False | None | False | 26595.0 | 0 | 3600821 | 131053 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)"
External & Shafts & Terrace
50mm DWS
| Rmtr | 893.32 | 893.32 | 15.0 | False | None | None | False | None | False | 13399.8 | 0 | 3600822 | 131053 | None | V-2,A-13,IT.NO 66 | Brass bib-cock 15 mm dia
| No | 354.35 | 354.35 | 4.0 | False | None | None | False | None | False | 1417.4 | 0 | 3600823 | 131053 | None | V-2 IT.NO 13.34 | KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. (For 1000 litre capacity)
Specification No.KBS 13.22 | No | 11.15 | 11.15 | 1000.0 | False | None | None | False | None | False | 11150.0 | 0 | 3600824 | 131053 | None | Market Rate | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards
Ground Toilet
10Cms X 7.5Cms
| No | 371.7 | 371.7 | 10.0 | False | None | None | False | None | False | 3717.0 | 0 | 3600825 | 131053 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
| No | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 | 3600826 | 131053 | None | Market Rate | Drilling holes of 2.50 cms dia (roof/chajja/stone).
-do- in slabs upto 7.50 cms thick
| No | 154.58 | 154.58 | 5.0 | False | None | None | False | None | False | 772.9 | 0 | 3600827 | 131053 | None | Market Rate | Drilling holes of 2.50 cms dia (roof/chajja/stone).
-do- in slabs upto 10 cms thick
| No | 185.26 | 185.26 | 5.0 | False | None | None | False | None | False | 926.3 | 0 | 3600828 | 131053 | None | Market Rate | Air Vent Cowel
75mm
| No | 413.0 | 413.0 | 10.0 | False | None | None | False | None | False | 4130.0 | 0 | 3600829 | 131053 | None | Market Rate | Air Vent Cowel
110mm
| No | 590.0 | 590.0 | 10.0 | False | None | None | False | None | False | 5900.0 | 0 | 3600830 | 131053 | None | Market Rate | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards
| No | 5664.0 | 5664.0 | 2.0 | False | None | None | False | None | False | 11328.0 | 0 | 3600831 | 131053 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
| No | 2183.0 | 2183.0 | 1.0 | False | None | None | False | None | False | 2183.0 | 0 | 3600832 | 131053 | None | Market Rate | Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent )
| No | 1996.56 | 1996.56 | 2.0 | False | None | None | False | None | False | 3993.12 | 0 | 3600833 | 131053 | None | Market Rate | Providing and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot.
| Each | 295.0 | 295.0 | 5.0 | False | None | None | False | None | False | 1475.0 | 0 | 3600834 | 131053 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
c) 50mm dia | No | 3304.0 | 3304.0 | 2.0 | False | None | None | False | None | False | 6608.0 | 0 | 3600835 | 131053 | None | CPWD SR, V-2,377,1927 | Brass full way valve with C.I. wheel (screwed end) 25 mm dia | Each | 442.5 | 442.5 | 3.0 | False | None | None | False | None | False | 1327.5 | 0 | 3600836 | 131053 | None | CPWD SR, V-2,377,1928 | Brass full way valve with C.I. wheel (screwed end) 32 mm dia | Each | 489.7 | 489.7 | 3.0 | False | None | None | False | None | False | 1469.1 | 0 | 3600837 | 131053 | None | CPWD SR, V-2,377,1929 | Brass full way valve with C.I. wheel (screwed end) 40 mm dia | Each | 590.0 | 590.0 | 2.0 | False | None | None | False | None | False | 1180.0 | 0 | 3600838 | 131053 | None | 8.3.1 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. | Each | 37498.0 | 37498.0 | 1.0 | False | None | None | False | None | False | 37498.0 | 0 |
| 1721809518000 | 0 | None | None | Buildings | HEMALAPUR PHC NURSE QTRS(INERNAL ELECTRICAL) | 150783.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600839 | 131054 | None | IT.NO 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Short point up to 3Mtr from tapping point to out let via switch box
| Point | 333.29 | 333.29 | 6.0 | False | None | None | False | None | False | 1999.74 | 0 | 3600840 | 131054 | None | IT.NO 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box
| Point | 469.58 | 469.58 | 7.0 | False | None | None | False | None | False | 3287.06 | 0 | 3600841 | 131054 | None | IT.NO 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box
| Point | 687.65 | 687.65 | 7.0 | False | None | None | False | None | False | 4813.55 | 0 | 3600842 | 131054 | None | IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
| Each | 170.98 | 170.98 | 9.0 | False | None | None | False | None | False | 1538.82 | 0 | 3600843 | 131054 | None | IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
| Each | 197.0 | 197.0 | 1.0 | False | None | None | False | None | False | 197.0 | 0 | 3600844 | 131054 | None | IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
| Each | 219.3 | 219.3 | 1.0 | False | None | None | False | None | False | 219.3 | 0 | 3600845 | 131054 | None | IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8Way
| Each | 272.58 | 272.58 | 3.0 | False | None | None | False | None | False | 817.74 | 0 | 3600846 | 131054 | None | IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
| Each | 323.38 | 323.38 | 2.0 | False | None | None | False | None | False | 646.76 | 0 | 3600847 | 131054 | None | IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
| Each | 216.83 | 216.83 | 1.0 | False | None | None | False | None | False | 216.83 | 0 | 3600848 | 131054 | None | IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4Moudule
| Each | 216.83 | 216.83 | 1.0 | False | None | None | False | None | False | 216.83 | 0 | 3600849 | 131054 | None | IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6Moudule
| Each | 289.93 | 289.93 | 1.0 | False | None | None | False | None | False | 289.93 | 0 | 3600850 | 131054 | None | IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8Moudule
| Each | 351.88 | 351.88 | 3.0 | False | None | None | False | None | False | 1055.64 | 0 | 3600851 | 131054 | None | IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10Moudule
| Each | 426.22 | 426.22 | 2.0 | False | None | None | False | None | False | 852.44 | 0 | 3600852 | 131054 | None | IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way.
| Each | 126.38 | 126.38 | 28.0 | False | None | None | False | None | False | 3538.64 | 0 | 3600853 | 131054 | None | IT.NO 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way.
| Each | 205.67 | 205.67 | 4.0 | False | None | None | False | None | False | 822.68 | 0 | 3600854 | 131054 | None | IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket.
| Each | 211.87 | 211.87 | 10.0 | False | None | None | False | None | False | 2118.7 | 0 | 3600855 | 131054 | None | IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
| Each | 442.32 | 442.32 | 3.0 | False | None | None | False | None | False | 1326.96 | 0 | 3600856 | 131054 | None | IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
| Each | 403.91 | 403.91 | 3.0 | False | None | None | False | None | False | 1211.73 | 0 | 3600857 | 131054 | None | IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
| Each | 292.4 | 292.4 | 3.0 | False | None | None | False | None | False | 877.2 | 0 | 3600858 | 131054 | None | IT.NO 3.6.12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket
| Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3600859 | 131054 | None | IT.NO 13.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.
Ding Dong Bell
| Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3600860 | 131054 | None | IT.NO 1.12 | Supplyin and Fixing Metal Fan Box with Round Hook.
| No | 144.96 | 144.96 | 3.0 | False | None | None | False | None | False | 434.88 | 0 | 3600861 | 131054 | None | ITM 1.2.1 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
| Rmtr | 81.77 | 81.77 | 160.0 | False | None | None | False | None | False | 13083.2 | 0 | 3600862 | 131054 | None | ITM 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
| Rmtr | 96.64 | 96.64 | 70.0 | False | None | None | False | None | False | 6764.8 | 0 | 3600863 | 131054 | None | ITM 1.2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
| Rmtr | 127.66 | 127.66 | 20.0 | False | None | None | False | None | False | 2553.2 | 0 | 3600864 | 131054 | None | ITM 1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)
19/20mm dia 2mm thick
| Rmtr | 84.25 | 84.25 | 75.0 | False | None | None | False | None | False | 6318.75 | 0 | 3600865 | 131054 | None | ITM 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)
25mm dia 2mm thick
| Rmtr | 97.88 | 97.88 | 40.0 | False | None | None | False | None | False | 3915.2 | 0 | 3600866 | 131054 | None | ITM 1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3)
32mm dia 2.5mm thick
| Rmtr | 122.66 | 122.66 | 10.0 | False | None | None | False | None | False | 1226.6 | 0 | 3600867 | 131054 | None | ITM 2.5.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5)
1.5 sqmm
| Rmtr | 32.21 | 32.21 | 75.0 | False | None | None | False | None | False | 2415.75 | 0 | 3600868 | 131054 | None | ITM 2.5.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5)
2.5 sqmm
| Rmtr | 52.04 | 52.04 | 180.0 | False | None | None | False | None | False | 9367.2 | 0 | 3600869 | 131054 | None | ITM 2.5.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5)
4 sqmm
| Rmtr | 78.06 | 78.06 | 60.0 | False | None | None | False | None | False | 4683.6 | 0 | 3600870 | 131054 | None | BSR-32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
2 core 10 sqmm
| Km | 125279.01 | 125279.01 | 0.1 | False | None | None | False | None | False | 12527.901 | 0 | 3600871 | 131054 | None | BSR-31 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
2.5 sqmm to 25 sqmm
| Km | 20021.0 | 20021.0 | 0.1 | False | None | None | False | None | False | 2002.1 | 0 | 3600872 | 131054 | None | SR 19-20 ITM 6.11 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
19/20mm
| Each | 84.25 | 84.25 | 4.0 | False | None | None | False | None | False | 337.0 | 0 | 3600873 | 131054 | None | SR 19-20 ITM 6.6.2 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)
In soil (hard)
| Rmtr | 126.38 | 126.38 | 60.0 | False | None | None | False | None | False | 7582.8 | 0 | 3600874 | 131054 | None | ITM 8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.
2Pair
| Rmtr | 26.02 | 26.02 | 20.0 | False | None | None | False | None | False | 520.4 | 0 | 3600875 | 131054 | None | ITM8.3 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.
MCB DB
| Rmtr | 54.52 | 54.52 | 25.0 | False | None | None | False | None | False | 1363.0 | 0 | 3600876 | 131054 | None | ITM5.18.8 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
Double Door
12 Way SP & N | Each | 3771.52 | 3771.52 | 1.0 | False | None | None | False | None | False | 3771.52 | 0 | 3600877 | 131054 | None | ITM5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps SP
| Each | 514.19 | 514.19 | 10.0 | False | None | None | False | None | False | 5141.9 | 0 | 3600878 | 131054 | None | ITM 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
| Each | 6538.2 | 6538.2 | 1.0 | False | None | None | False | None | False | 6538.2 | 0 | 3600879 | 131054 | None | ITM 11.3 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fighting 1 x4'- 20/22 w
| Each | 854.91 | 854.91 | 6.0 | False | None | None | False | None | False | 5129.46 | 0 | 3600880 | 131054 | None | ITM 12.46 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
| Each | 183.37 | 183.37 | 8.0 | False | None | None | False | None | False | 1466.96 | 0 | 3600881 | 131054 | None | ITM11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
7 W, 6500K
| Each | 184.61 | 184.61 | 3.0 | False | None | None | False | None | False | 553.83 | 0 | 3600882 | 131054 | None | itm11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
12 W, 6500K | Each | 333.29 | 333.29 | 1.0 | False | None | None | False | None | False | 333.29 | 0 | 3600883 | 131054 | None | Itm 11.11.7 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
18W, 6500K | Each | 527.81 | 527.81 | 2.0 | False | None | None | False | None | False | 1055.62 | 0 | 3600884 | 131054 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply | No | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3600885 | 131054 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1849.0 | 1849.0 | 2.0 | False | None | None | False | None | False | 3698.0 | 0 | 3600886 | 131054 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod
blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | Each | 3697.18 | 3697.18 | 3.0 | False | None | None | False | None | False | 11091.54 | 0 | 3600887 | 131054 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
| Each | 151.15 | 151.15 | 6.0 | False | None | None | False | None | False | 906.9 | 0 | 3600888 | 131054 | None | 13.10 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 211.86 | 211.86 | 3.0 | False | None | None | False | None | False | 635.58 | 0 | 3600889 | 131054 | None | 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 875.97 | 875.97 | 2.0 | False | None | None | False | None | False | 1751.94 | 0 | 3600890 | 131054 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, e | Each | 1810.18 | 1810.18 | 1.0 | False | None | None | False | None | False | 1810.18 | 0 | 3600891 | 131054 | None | 13.4.1 | Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.
Single bracket 1.5 Mtr. Length
| Each | 1810.18 | 1810.18 | 1.0 | False | None | None | False | None | False | 1810.18 | 0 | 3600892 | 131054 | None | 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 200.71 | 200.71 | 1.0 | False | None | None | False | None | False | 200.71 | 0 | 3600893 | 131054 | None | 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
6-32Amps DP
| Each | 915.62 | 915.62 | 1.0 | False | None | None | False | None | False | 915.62 | 0 | 3600894 | 131054 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers
32Amps
| Each | 298.59 | 298.59 | 1.0 | False | None | None | False | None | False | 298.59 | 0 | 3600895 | 131054 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
| Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 |
| 1721809518000 | 0 | None | None | Buildings | Barur PHC (Consultancy For Architectural, Structural Design Charges) | 347942.74 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600896 | 131055 | None | DATA RATE | The Tenderer (agency) should arrange to obtain (get), detailed Architecturaldrawings and elevations, Structural designs and drawings including Soil exploration & proofchecking by IISC /IIT/NIT/any Engineering college only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
| LS | 347942.74 | 347942.74 | 1.0 | False | None | None | False | None | False | 347942.74 | 0 |
| 1721809518000 | 0 | None | None | Buildings | HEMALAPUR PHC(Consultancy For Architectural, Structural Design Charges) | 347942.74 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3600897 | 131056 | None | DATA RATE | The Tenderer (agency) should arrange to obtain (get), detailed Architecturaldrawings and elevations, Structural designs and drawings including Soil exploration & proofchecking by IISC /IIT/NIT/any Engineering college only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge
| LS | 347942.74 | 347942.74 | 1.0 | False | None | None | False | None | False | 347942.74 | 0 |
|
|
---|