createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721809517099
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1069000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 16:00:00
tenderQueryClose14-08-2024 16:00:00
technicalBidOpen27-08-2024 16:01:00
publishedDate24-07-2024 14:08:01
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate19-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9686183379
tenderSupplierListNone
tenderSchedule
createdTs1721809517132
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT543
titlePackage-I(1)Construction of Primary Health Center at Barur,In Bidar Taluk,In Bidar District.(2)Construction of Primary Health Center at Hemalapur,In Bidar Taluk,In Bidar District
descriptionPackage-I(1)Construction of Primary Health Center at Barur,In Bidar Taluk,In Bidar District.(2)Construction of Primary Health Center at Hemalapur,In Bidar Taluk,In Bidar District
categoryWORKS
categoryTextWorks
ecv71218845.74
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount80000000.0
groupOverheadTotal0.0
fileNumberHFW/AEE/KKRDB/15FINANCE/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218095170000NoneNoneBuildingsBarur PHC(Civil Works)19709674.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3599882131021NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle100 Sqm486.93486.9320.0FalseNoneNoneFalseNoneFalse9738.60
3599883131021NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.71117.71222.09FalseNoneNoneFalseNoneFalse26142.21390
3599884131021NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.38126.38670.52FalseNoneNoneFalseNoneFalse84740.31760
3599885131021NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthCum449.76449.76167.63FalseNoneNoneFalseNoneFalse75393.26880
3599886131021NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)Cum167.27167.27100.0FalseNoneNoneFalseNoneFalse16727.00
3599887131021NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2570.14FalseNoneNoneFalseNoneFalse83354.4680
3599888131021NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57670.52FalseNoneNoneFalseNoneFalse220983.27640
3599889131021NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.29143.97FalseNoneNoneFalseNoneFalse84552.14130
3599890131021NoneV-1page 15 itm2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.37123.48FalseNoneNoneFalseNoneFalse916267.28760
3599891131021NoneV-1page15 itm 2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Formwork, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregatesCum8412.768412.7694.25FalseNoneNoneFalseNoneFalse792902.630
3599892131021NoneV-1page16 itm 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum14413.4114413.4137.06FalseNoneNoneFalseNoneFalse534160.97460
3599893131021NoneV-1page15itm 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum7702.867702.866.96FalseNoneNoneFalseNoneFalse53611.90560
3599894131021NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/EpoxyNo252.76252.7630.0FalseNoneNoneFalseNoneFalse7582.80
3599895131021NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3599896131021NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - BuildingsTonne110837.22110837.2237.25FalseNoneNoneFalseNoneFalse4128686.4450
3599897131021None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBSRmtr38.9438.94111.0FalseNoneNoneFalseNoneFalse4322.340
3599898131021NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.Rmtr86.1486.14111.0FalseNoneNoneFalseNoneFalse9561.540
3599899131021NoneV-2PAGE 9 ITM5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7688.07688.017.19FalseNoneNoneFalseNoneFalse132156.720
3599900131021NoneV-2PAGE 14 ITM 6.32Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.59199.58FalseNoneNoneFalseNoneFalse1970571.09220
3599901131021NoneV-2page 14 itm 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum1209.261209.2686.23FalseNoneNoneFalseNoneFalse104274.48980
3599902131021NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.99FalseNoneNoneFalseNoneFalse121207.47210
3599903131021NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.8214.0FalseNoneNoneFalseNoneFalse17623.480
3599904131021NoneV-2page 104 itm 12.51Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1314.581314.5814.0FalseNoneNoneFalseNoneFalse18404.120
3599905131021NoneV-2 page 105 itm 12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.6114.0FalseNoneNoneFalseNoneFalse17172.540
3599906131021NoneV-2page 105 itm 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6428.0FalseNoneNoneFalseNoneFalse8221.920
3599907131021NoneV-2page 105itm 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0728.0FalseNoneNoneFalseNoneFalse4509.960
3599908131021NoneV-2page105 itm 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1514.0FalseNoneNoneFalseNoneFalse954.10
3599909131021NoneV-2page107itm12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7328.0FalseNoneNoneFalseNoneFalse9540.440
3599910131021NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3484.0FalseNoneNoneFalseNoneFalse6244.560
3599911131021NoneXI page 18-19 SR313 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.Rmtr15.015.0105.8FalseNoneNoneFalseNoneFalse1587.00
3599912131021NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.964115.9641.21FalseNoneNoneFalseNoneFalse169618.71160
3599913131021NoneV-2page109 itm 12.87Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6977.31FalseNoneNoneFalseNoneFalse627501.30390
3599914131021NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.846.48FalseNoneNoneFalseNoneFalse45916.24320
3599915131021NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg208.15208.152159.01FalseNoneNoneFalseNoneFalse449397.93150
3599916131021NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mmm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3599917131021NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs168.5168.5120.96FalseNoneNoneFalseNoneFalse20381.760
3599918131021NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)Sqm386.57386.571049.85FalseNoneNoneFalseNoneFalse405840.51450
3599919131021NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.43531.95FalseNoneNoneFalseNoneFalse139067.68850
3599920131021NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.91581.8FalseNoneNoneFalseNoneFalse195985.020
3599921131021NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)Sqm432.41432.411016.08FalseNoneNoneFalseNoneFalse439363.15280
3599922131021NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm438.61438.6129.15FalseNoneNoneFalseNoneFalse12785.48150
3599923131021None118page18-19 SR15.36Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )Rmtr36.5836.58800.0FalseNoneNoneFalseNoneFalse29264.00
3599924131021None18-19 SR0.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.Sqm254.88254.8820.0FalseNoneNoneFalseNoneFalse5097.60
3599925131021NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.Rmtr64.4364.43709.5FalseNoneNoneFalseNoneFalse45713.0850
3599926131021NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mmSqm1455.831455.83293.21FalseNoneNoneFalseNoneFalse426863.91430
3599927131021NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3599928131021NoneV-2page63 itm 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm3055.373055.37214.93FalseNoneNoneFalseNoneFalse656690.67410
3599929131021NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm365.51365.51891.34FalseNoneNoneFalseNoneFalse325793.68340
3599930131021NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.Sqm1101.471101.4729.98FalseNoneNoneFalseNoneFalse33022.07060
3599931131021NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1795.311795.31891.34FalseNoneNoneFalseNoneFalse1600231.61540
3599932131021NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg700.04700.04260.78FalseNoneNoneFalseNoneFalse182556.43120
3599933131021NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm157.35157.351581.8FalseNoneNoneFalseNoneFalse248896.230
3599934131021NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28762.06FalseNoneNoneFalseNoneFalse147290.95680
3599935131021NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm61.9561.9583.79FalseNoneNoneFalseNoneFalse5190.79050
3599936131021NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm142.49142.4983.79FalseNoneNoneFalseNoneFalse11939.23710
3599937131021NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6798.89FalseNoneNoneFalseNoneFalse6494.10630
3599938131021NoneV-2page49itm 8.47Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm167.27167.2798.89FalseNoneNoneFalseNoneFalse16541.33030
3599939131021NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3599940131021NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm5548.245548.243.15FalseNoneNoneFalseNoneFalse17476.9560
3599941131021NoneLQRRoof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane. System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification. Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant. Sqm1593.01593.0633.5FalseNoneNoneFalseNoneFalse1009165.50
3599942131021NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specificationsSqm411.35411.3516.34FalseNoneNoneFalseNoneFalse6721.4590
3599943131021NoneV-2PAGE27ITM 7.40Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.Sqm2118.692118.6948.84FalseNoneNoneFalseNoneFalse103476.81960
3599944131021NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9326.329326.3220.24FalseNoneNoneFalseNoneFalse188764.71680
3599945131021NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.7244.58FalseNoneNoneFalseNoneFalse566955.95760
3599946131021NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13565.5613565.5630.15FalseNoneNoneFalseNoneFalse409001.6340
3599947131021NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.7287.68FalseNoneNoneFalseNoneFalse1115089.68960
3599948131021NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.724.32FalseNoneNoneFalseNoneFalse54940.55040
3599949131021NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.7213.25FalseNoneNoneFalseNoneFalse168509.790
3599950131021NoneITEM 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar dropsSqm350.64350.64254.02FalseNoneNoneFalseNoneFalse89069.57280
3599951131021None12.94.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thickSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
17218095170000NoneNoneBuildingsBarur PHC(Internal WS AND SANITARY)1166957.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3599952131022NoneV-2 P.NO 135 IT.NO 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Rmtr113.99113.9940.0FalseNoneNoneFalseNoneFalse4559.60
3599953131022NoneV-5 P.NO 187 IT.NO T090DProviding and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines Rmtr213.38213.3820.0FalseNoneNoneFalseNoneFalse4267.60
3599954131022NoneV-5 P.NO 34 IT.NO 3711Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Rmtr337.73337.7350.0FalseNoneNoneFalseNoneFalse16886.50
3599955131022NoneV-5 P.NO 34 IT.NO 3713Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Rmtr630.94630.94180.0FalseNoneNoneFalseNoneFalse113569.20
3599956131022NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter Rmtr244.08244.0825.0FalseNoneNoneFalseNoneFalse6102.00
3599957131022NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter Rmtr360.55360.5560.0FalseNoneNoneFalseNoneFalse21633.00
3599958131022NoneV-2 P.NO 128 IT.NO 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. No1511.581511.5820.0FalseNoneNoneFalseNoneFalse30231.60
3599959131022NoneV-2 P.NO 116 IT.NO 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter No345.68345.683.0FalseNoneNoneFalseNoneFalse1037.040
3599960131022NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. No6891.326891.323.0FalseNoneNoneFalseNoneFalse20673.960
3599961131022NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. No614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3599962131022NoneV-2 P.NO 123 IT.NO 14.3Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required No7192.47192.48.0FalseNoneNoneFalseNoneFalse57539.20
3599963131022NoneV-2 P.NO 178 IT.NO 20.44.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm No4394.734394.7310.0FalseNoneNoneFalseNoneFalse43947.30
3599964131022NoneV-2 P.NO 124 IT.NO14.4.4Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern No16193.7316193.734.0FalseNoneNoneFalseNoneFalse64774.920
3599965131022NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3599966131022NoneV-2 P.NO 126 IT.NO 14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm No5986.855986.852.0FalseNoneNoneFalseNoneFalse11973.70
3599967131022NoneV-2 P.NO A-14 IT.NO 91C.P. Brass stop cock (concealed) 15 mm No650.48650.4810.0FalseNoneNoneFalseNoneFalse6504.80
3599968131022NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps No3818.63818.65.0FalseNoneNoneFalseNoneFalse19093.00
3599969131022NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm diaRmtr382.85382.8560.0FalseNoneNoneFalseNoneFalse22971.00
3599970131022NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm diaRmtr469.58469.5850.0FalseNoneNoneFalseNoneFalse23479.00
3599971131022NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3599972131022NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3599973131022NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3599974131022NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3599975131022NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3599976131022NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS Rmtr893.32893.3225.0FalseNoneNoneFalseNoneFalse22333.00
3599977131022NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS Rmtr591.0591.0150.0FalseNoneNoneFalseNoneFalse88650.00
3599978131022NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS Rmtr1734.61734.623.0FalseNoneNoneFalseNoneFalse39895.80
3599979131022NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS Rmtr893.32893.3225.0FalseNoneNoneFalseNoneFalse22333.00
3599980131022NoneCPWD SR, V-2,P.NO 109,IT.NO 1927Brass full way valve with C.I. wheel (screwed end) 25 mm dia Each442.5442.510.0FalseNoneNoneFalseNoneFalse4425.00
3599981131022NoneCPWD SR, V-2, P.NO 110,IT.NO 1928Brass full way valve with C.I. wheel (screwed end) 32 mm dia Each489.7489.75.0FalseNoneNoneFalseNoneFalse2448.50
3599982131022NoneCPWD SR, V-2, P.NO 111,IT.NO 1929Brass full way valve with C.I. wheel (screwed end) 40 mm dia Each590.0590.05.0FalseNoneNoneFalseNoneFalse2950.00
3599983131022NoneCPWD SR, V-2,P.NO 112,IT.NO 1930Brass full way valve with C.I. wheel (screwed end) 50 mm dia Each737.5737.52.0FalseNoneNoneFalseNoneFalse1475.00
3599984131022NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia No354.35354.3515.0FalseNoneNoneFalseNoneFalse5315.250
3599985131022NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. No11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
3599986131022NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. 100 Liter capacity No37498.0437498.042.0FalseNoneNoneFalseNoneFalse74996.080
3599987131022NoneMarket RateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards Ground Toilet 10Cms X 7.5Cms No371.7371.745.0FalseNoneNoneFalseNoneFalse16726.50
3599988131022NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) No177.0177.045.0FalseNoneNoneFalseNoneFalse7965.00
3599989131022NoneMarket RateAir Vent Cowel 75mm No413.0413.020.0FalseNoneNoneFalseNoneFalse8260.00
3599990131022NoneMarket RateAir Vent Cowel 110mm No590.0590.020.0FalseNoneNoneFalseNoneFalse11800.00
3599991131022NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. brass pillar taps with C.I. /M.S. brackets, 32 mm C.P. brass waste of standard pattern, including Brass stop cock, 32mm PVC connection painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification as directed by the Engineer in charge. CNS-WHT-705, make Jaguar/hindware/Cera No5664.05664.020.0FalseNoneNoneFalseNoneFalse113280.00
3599992131022NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). No2183.02183.08.0FalseNoneNoneFalseNoneFalse17464.00
3599993131022NoneMarket RateSupplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) No1996.561996.564.0FalseNoneNoneFalseNoneFalse7986.240
3599994131022NoneMarket RateProviding and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.No1147.91147.910.0FalseNoneNoneFalseNoneFalse11479.00
3599995131022NoneMarket RateProviding and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot. -do- 10cms x 7.5 cms Each295.0295.010.0FalseNoneNoneFalseNoneFalse2950.00
3599996131022NoneMarket RateSupplying, fixing, testing and commissioning of single sink with large basin for Hospital use. Pedal-controlled faucet and button-controlled soap dispenser. The basin is supplied complete with drain, siphon, flexible connection to the water mains and plugs for wall mounting.No25370.025370.01.0FalseNoneNoneFalseNoneFalse25370.00
3599997131022NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. No767.0767.065.0FalseNoneNoneFalseNoneFalse49855.00
3599998131022NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3599999131022NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia No3304.03304.02.0FalseNoneNoneFalseNoneFalse6608.00
17218095170000NoneNoneBuildingsBarur PHC(EXTERNAL WS & SANITARY)1181322.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600000131023NoneV-1,P.NO 6,IT.NO 1.5Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum370.46370.46278.0FalseNoneNoneFalseNoneFalse102987.880
3600001131023NoneV-1 P.NO 7 IT.NO 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum329.57329.57278.0FalseNoneNoneFalseNoneFalse91620.460
3600002131023NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). - do - 160 mm dia Rmtr713.66713.66350.0FalseNoneNoneFalseNoneFalse249781.00
3600003131023NoneV-5,P.NO 134,IT.NO- 10.2.5Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). - do - 200 mm dia Rmtr1029.611029.6160.0FalseNoneNoneFalseNoneFalse61776.60
3600004131023NoneV-5 P.NO 134 IT.NO 10.2.6Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). - do - 250 mm dia Rmtr1578.491578.4910.0FalseNoneNoneFalseNoneFalse15784.90
3600005131023NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3600006131023NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3600007131023NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3600008131023NoneMARKET RATEProviding stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms No330.4330.425.0FalseNoneNoneFalseNoneFalse8260.00
3600009131023NoneIT.NO 11.39KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22 m internal dia at bottom, 1.68 m deep and 0.56m dia at top, with table moulded and non modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and down size granite metal and making necessary channel in cement concrete M 15 with 20mm and down size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, total weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 No36325.036325.01.0FalseNoneNoneFalseNoneFalse36325.00
3600010131023NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3600011131023NoneMarket RateSupply and fixing of GM ball cock with copper float(High pressure float)of ISI or BIS Standardsand & fixed on to the inlet pipe at the underground sump tank & OHT. No5900.05900.05.0FalseNoneNoneFalseNoneFalse29500.00
3600012131023NoneCSRPUMPS Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (DOMESTIC)2.00 HP Each41300.041300.02.0FalseNoneNoneFalseNoneFalse82600.00
17218095170000NoneNoneBuildingsBarur PHC(INETRNAL ELECTRICAL)1238058.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600013131024NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch Point333.29333.2936.0FalseNoneNoneFalseNoneFalse11998.440
3600014131024NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch Pack469.58469.5845.0FalseNoneNoneFalseNoneFalse21131.10
3600015131024NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch Point687.65687.6560.0FalseNoneNoneFalseNoneFalse41259.00
3600016131024NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint838.8838.84.0FalseNoneNoneFalseNoneFalse3355.20
3600017131024NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way Each170.89170.8920.0FalseNoneNoneFalseNoneFalse3417.80
3600018131024NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Each197.0197.010.0FalseNoneNoneFalseNoneFalse1970.00
3600019131024NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Each219.3219.310.0FalseNoneNoneFalseNoneFalse2193.00
3600020131024NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way Each272.58272.5822.0FalseNoneNoneFalseNoneFalse5996.760
3600021131024NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Each323.38323.3825.0FalseNoneNoneFalseNoneFalse8084.50
3600022131024NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module Each199.48199.4820.0FalseNoneNoneFalseNoneFalse3989.60
3600023131024NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Each216.83216.8310.0FalseNoneNoneFalseNoneFalse2168.30
3600024131024NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module Each289.93289.9310.0FalseNoneNoneFalseNoneFalse2899.30
3600025131024NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Each351.88351.8822.0FalseNoneNoneFalseNoneFalse7741.360
3600026131024NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module Each426.22426.2225.0FalseNoneNoneFalseNoneFalse10655.50
3600027131024NonePWD ELE SR V-27 IT.NO 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch Each126.38126.38216.0FalseNoneNoneFalseNoneFalse27298.080
3600028131024NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3600029131024NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket Each211.87211.8772.0FalseNoneNoneFalseNoneFalse15254.640
3600030131024NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Each442.32442.3220.0FalseNoneNoneFalseNoneFalse8846.40
3600031131024NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch Each223.02223.027.0FalseNoneNoneFalseNoneFalse1561.140
3600032131024NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3600033131024NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket Each292.4292.422.0FalseNoneNoneFalseNoneFalse6432.80
3600034131024NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. No144.96144.9620.0FalseNoneNoneFalseNoneFalse2899.20
3600035131024NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick Rmtr81.7781.77450.0FalseNoneNoneFalseNoneFalse36796.50
3600036131024NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick Rmtr96.6496.64650.0FalseNoneNoneFalseNoneFalse62816.00
3600037131024NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick Rmtr127.62127.6280.0FalseNoneNoneFalseNoneFalse10209.60
3600038131024NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick Rmtr84.2584.25180.0FalseNoneNoneFalseNoneFalse15165.00
3600039131024NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. Rmtr97.8897.88260.0FalseNoneNoneFalseNoneFalse25448.80
3600040131024NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick Rmtr122.66122.6632.0FalseNoneNoneFalseNoneFalse3925.120
3600041131024NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm Rmtr32.2132.21300.0FalseNoneNoneFalseNoneFalse9663.00
3600042131024NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm Rmtr52.0452.04940.0FalseNoneNoneFalseNoneFalse48917.60
3600043131024NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm Rmtr78.0678.06400.0FalseNoneNoneFalseNoneFalse31224.00
3600044131024NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm Rmtr113.99113.99280.0FalseNoneNoneFalseNoneFalse31917.20
3600045131024NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3600046131024NonePWD ELE SR V-6,IT.NO 5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N Each2308.262308.261.0FalseNoneNoneFalseNoneFalse2308.260
3600047131024NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP Each514.19514.1934.0FalseNoneNoneFalseNoneFalse17482.460
3600048131024NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3600049131024NonePWD ELE SR V-6,IT.NO 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps DP Each915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3600050131024NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole Each6538.26538.26.0FalseNoneNoneFalseNoneFalse39229.20
3600051131024NonePWD ELE SR V-6,IT.NO5.20.2Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32 -40 Amps 2 pole Each5648.65648.61.0FalseNoneNoneFalseNoneFalse5648.60
3600052131024NonePWD ELE SR V-6 BSR-32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm Km258542.13258542.130.2FalseNoneNoneFalseNoneFalse51708.4260
3600053131024NonePWD ELE SR V-6,IT.NO BSR-31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm Km29298.6329298.630.2FalseNoneNoneFalseNoneFalse5859.7260
3600054131024NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia Each144.96144.968.0FalseNoneNoneFalseNoneFalse1159.680
3600055131024NonePWD ELE SR V-6,IT.NO 6.9.2Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 50mm Rmtr470.82470.8210.0FalseNoneNoneFalseNoneFalse4708.20
3600056131024NoneSR 19-20 IT.NO 6.6.2Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (hard) Rmtr126.38126.3890.0FalseNoneNoneFalseNoneFalse11374.20
3600057131024NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel Each39.6539.658.0FalseNoneNoneFalseNoneFalse317.20
3600058131024NonePWD ELE SR V-6,IT.NO 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 3CX2.5 Sq mm Rmtr140.01140.0150.0FalseNoneNoneFalseNoneFalse7000.50
3600059131024NonePWD ELE SR V-6 IT.NO2.6.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 3CX4 Sq mm Rmtr206.91206.91100.0FalseNoneNoneFalseNoneFalse20691.00
3600060131024NoneSR 19-20 IT.NO 6.1Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. No3716.633716.634.0FalseNoneNoneFalseNoneFalse14866.520
3600061131024NoneSR 19-20 IT.NO 6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip Rmtr92.9392.9330.0FalseNoneNoneFalseNoneFalse2787.90
3600062131024NonePWD ELE SR V-6,IT.NO 6.3.4Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 50x6mm GI strip Rmtr241.61241.6120.0FalseNoneNoneFalseNoneFalse4832.20
3600063131024NonePWD ELE SR V-6,IT.NO 11.3.2Supplying of .feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach854.91854.9170.0FalseNoneNoneFalseNoneFalse59843.70
3600064131024NonePWD ELE SR V-6,IT.NO 11.6.2Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' / 1' x 4' 34 -36wattNo7307.627307.6212.0FalseNoneNoneFalseNoneFalse87691.440
3600065131024NonePWD ELE SR V-6,IT.NO 11.11.3Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500KNo184.61184.618.0FalseNoneNoneFalseNoneFalse1476.880
3600066131024NonePWD ELE SR V-6,IT.NO 11.11.5Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K No333.29333.2913.0FalseNoneNoneFalseNoneFalse4332.770
3600067131024NonePWD ELE SR V-6,IT.NO 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply No64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3600068131024NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1848.591848.5910.0FalseNoneNoneFalseNoneFalse18485.90
3600069131024NonePWD ELE SR V-6,IT.NO 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Each3697.183697.1820.0FalseNoneNoneFalseNoneFalse73943.60
3600070131024NonePWD ELE SR V-6,IT.NO 6.5.1Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep Each3087.593087.593.0FalseNoneNoneFalseNoneFalse9262.770
3600071131024NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each151.16151.1681.0FalseNoneNoneFalseNoneFalse12243.960
3600072131024NonePWD ELE SR V-6,IT.NO 13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each211.87211.8723.0FalseNoneNoneFalseNoneFalse4873.010
3600073131024NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Each875.97875.9710.0FalseNoneNoneFalseNoneFalse8759.70
3600074131024NonePWD ELE SR V-6,IT.NO 11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25wattsNo3004.583004.584.0FalseNoneNoneFalseNoneFalse12018.320
3600075131024NonePWD ELE SR V-6,IT.NO 13.2.2Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe Each1604.511604.514.0FalseNoneNoneFalseNoneFalse6418.040
3600076131024NonePWD ELE SR V-6,IT.NO 13.5Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Each200.72200.724.0FalseNoneNoneFalseNoneFalse802.880
3600077131024NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG Sq CM0.530.53110000.0FalseNoneNoneFalseNoneFalse58300.00
3600078131024NonePWD ELE SR V-6,IT.NO 5.40.1Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips Rmtr3054.143054.144.0FalseNoneNoneFalseNoneFalse12216.560
3600079131024NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm Rmtr377.9377.98.0FalseNoneNoneFalseNoneFalse3023.20
3600080131024NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel Rmtr936.68936.688.0FalseNoneNoneFalseNoneFalse7493.440
3600081131024NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3600082131024NonePWD ELE SR V-6,IT.NO 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN Each3771.523771.523.0FalseNoneNoneFalseNoneFalse11314.560
3600083131024NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP Each3826.033826.033.0FalseNoneNoneFalseNoneFalse11478.090
3600084131024NonePWD ELE SR V-6,IT.NO 5.11.2Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. 100Amps Each8784.518784.511.0FalseNoneNoneFalseNoneFalse8784.510
3600085131024NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3600086131024NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3600087131024NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3600088131024NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery Kvar594.72594.7210.0FalseNoneNoneFalseNoneFalse5947.20
3600089131024NonePWD ELE SR V-6,IT.NO 5.44.1Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. 300mmx300mmx214mmEach5590.375590.371.0FalseNoneNoneFalseNoneFalse5590.370
3600090131024NonePWD ELE SR V-6,IT.NO 5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. Each7068.57068.51.0FalseNoneNoneFalseNoneFalse7068.50
3600091131024NonePWD ELE SR V-6,IT.NO 3.6.12TELEPHONE & NETWORKING RJ45/ I.O. outlet Each417.54417.5411.0FalseNoneNoneFalseNoneFalse4592.940
3600092131024NonePWD ELE SR V-6,IT.NO 3.6.11Telephone socket Each193.28193.288.0FalseNoneNoneFalseNoneFalse1546.240
3600093131024NonePWD ELE SR V-6,IT.NO 8.1Supplying and drawing UTP-CAT 6E LAN cable. Rmtr47.0847.08300.0FalseNoneNoneFalseNoneFalse14124.00
3600094131024NonePWD ELE SR V-6,IT.NO 8.10.1Supplying & Fixing of I/O Socket with back box Single I/O Each607.11607.1111.0FalseNoneNoneFalseNoneFalse6678.210
3600095131024NonePWD ELE SR V-6,IT.NO 8.4.1Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 4U with 450mm depth Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3600096131024NonePWD ELE SR V-6,IT.NO 8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 Switch Each7979.167979.161.0FalseNoneNoneFalseNoneFalse7979.160
3600097131024NonePWD ELE SR V-6,IT.NO 8.11.1Supplying & fixing of .mtrs. Cat 6Patch Cable. 2Mtr Each318.42318.4211.0FalseNoneNoneFalseNoneFalse3502.620
3600098131024NonePWD ELE SR V-6,IT.NO 8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3600099131024NonePWD ELE SR V-6,IT.NO 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. Rmtr26.0226.02300.0FalseNoneNoneFalseNoneFalse7806.00
3600100131024NonePWD ELE SR V-6,IT.NO 8.13.1Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 Pair Each427.46427.461.0FalseNoneNoneFalseNoneFalse427.460
3600101131024NoneMARKET RATETELEPHONES Analog push button telephone with Caller ID, flash and radiaLNo1858.51858.58.0FalseNoneNoneFalseNoneFalse14868.00
3600102131024NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) Rmtr96.6496.64300.0FalseNoneNoneFalseNoneFalse28992.00
17218095170000NoneNoneBuildingsBarur PHC(EXTERNAL ELECTRICAL& DG SET)1241018.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600103131025NoneBSR- CDS-15Supply and fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles) Set31573.4431573.441.0FalseNoneNoneFalseNoneFalse31573.440
3600104131025NoneBSR- CDS-15Supply of 11 kV, 45 KN Polymeric Insulator No250.28250.286.0FalseNoneNoneFalseNoneFalse1501.680
3600105131025NoneBSR- CDS-15Supply and fixing of Guy Set Complete with No. 15 Strain Insulator & Concreting materials Set2053.022053.022.0FalseNoneNoneFalseNoneFalse4106.040
3600106131025NoneBSR- CDS-15Supply and fixing of Spiral Earth Electrode No394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3600107131025NoneBSR- CDS-15Fixing of Guy concreting with Boulders, Mud and Sand No247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3600108131025NoneBSR- CDS-15Supply and fixing of Caution/Danger Board No256.47256.471.0FalseNoneNoneFalseNoneFalse256.470
3600109131025NoneBSR- CDS-15Supply and fixing of Anti Climbing Device (12 Mtr GI Barbed Wire Each154.88154.882.0FalseNoneNoneFalseNoneFalse309.760
3600110131025NoneBSR- CDS-15Supply and fixing of 11 kV, 400 Amps Double Break GOS Set26541.8626541.861.0FalseNoneNoneFalseNoneFalse26541.860
3600111131025NoneBSR- CDS-15Supply and fixing of H-Frame for mounting GOS No5421.865421.861.0FalseNoneNoneFalseNoneFalse5421.860
3600112131025NoneBSR- CDS-15Supply and fixing of DOLO Cut Out Set of 3 Nos7248.157248.151.0FalseNoneNoneFalseNoneFalse7248.150
3600113131025NoneBSR- 13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. No203691.6203691.61.0FalseNoneNoneFalseNoneFalse203691.60
3600114131025NoneSR 19-20 6.1Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. No3716.633716.636.0FalseNoneNoneFalseNoneFalse22299.780
3600115131025NoneSR 19-20-6.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip Rmtr142.49142.4960.0FalseNoneNoneFalseNoneFalse8549.40
3600116131025NoneSR 19-20-6.3.8Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip Rmtr1771.771771.7760.0FalseNoneNoneFalseNoneFalse106306.20
3600117131025NoneSR 19-20-6.3.10Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate Each8549.18549.14.0FalseNoneNoneFalseNoneFalse34196.40
3600118131025NoneBSR-45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2) 3x95Sqmm.Outdoor Set4913.874913.873.0FalseNoneNoneFalseNoneFalse14741.610
3600119131025NoneBSR-45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2) 3x95Sqmm.Indoor Set4523.594523.592.0FalseNoneNoneFalseNoneFalse9047.180
3600120131025NoneBSR-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975." 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1382246.991382246.990.03FalseNoneNoneFalseNoneFalse41467.40970
3600121131025NoneBSR-38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint.Sqm1222.891222.8980.0FalseNoneNoneFalseNoneFalse97831.20
3600122131025NoneBSR-65.04Rubber Hand gloves 15 kV, SEAMLESS Confirming to ISS (Sample to be verified for seamless before approval) for electrical purpose Pair1365.381365.382.0FalseNoneNoneFalseNoneFalse2730.760
3600123131025NoneIT.NO 15.122Supplying of first aid box. Complete Each3717.03717.02.0FalseNoneNoneFalseNoneFalse7434.00
3600124131025NoneMARKET RATESupplying of FIRST AID CHART with lamination. Complete Each309.75309.752.0FalseNoneNoneFalseNoneFalse619.50
3600125131025NoneIT.NO 5.42.1LT KIOSK Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG Sq CM0.470.47110000.0FalseNoneNoneFalseNoneFalse51700.00
3600126131025NoneIT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips Rmtr3813.643813.644.0FalseNoneNoneFalseNoneFalse15254.560
3600127131025NoneIT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm Rmtr340.73340.738.0FalseNoneNoneFalseNoneFalse2725.840
3600128131025NoneIT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel Rmtr842.52842.528.0FalseNoneNoneFalseNoneFalse6740.160
3600129131025NoneIT.NO 5.14Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 125Amps 25kA Each12479.2112479.212.0FalseNoneNoneFalseNoneFalse24958.420
3600130131025NoneIT.NO 5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP Each1366.621366.624.0FalseNoneNoneFalseNoneFalse5466.480
3600131131025NoneIT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C Each574.9574.93.0FalseNoneNoneFalseNoneFalse1724.70
3600132131025None10.1.1Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class HMounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibr 15KVA/12kwSet432547.3432547.31.0FalseNoneNoneFalseNoneFalse432547.30
3600133131025None10.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility.15KVAEach72743.4672743.461.0FalseNoneNoneFalseNoneFalse72743.460
17218095170000NoneNoneBuildingsBarur PHC(SEPTIC TANK & SOAK PIT))477864.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600134131026NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3600135131026NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3600136131026NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3600137131026NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3600138131026NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.47FalseNoneNoneFalseNoneFalse5997.43890
3600139131026NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3600140131026NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.78FalseNoneNoneFalseNoneFalse197290.25160
3600141131026NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3600142131026NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3600143131026NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3600144131026NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3600145131026NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3600146131026NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3600147131026NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3600148131026NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3600149131026NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
17218095170000NoneNoneBuildingsBarur PHC(SUMP TANK)326860.58
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600150131027NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3600151131027NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3600152131027NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3600153131027NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3600154131027NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3600155131027NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3600156131027NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3600157131027NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3600158131027NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3600159131027NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3600160131027NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
17218095170000NoneNoneBuildingsBarur PHC(UPS)415116.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600161131028NonePWD SR 2023-24 Volume 6 It No-9.3.5Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3600162131028NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
17218095170000NoneNoneBuildingsBarur PHC(ACs)122781.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600163131029None6.8.2Supplyingof .TRInvertor type splitAirconditionerssuitable foroperation onA/Csupply singlephase50Hz230Vwith hermetically sealed inverter compressor with air cooled condenser, latestR410A/R-32refrigerant fanmotor,start& runcapacitors, relay&overloadprotector internal unit,with one indoor&one outdoor unit The condenser unit will be placedoutsidetheroomavoidnoiseincluding standardlength of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 3 star - 1.5 Ton capacityEach53435.1253435.122.0FalseNoneNoneFalseNoneFalse106870.240
3600164131029None6.10Installation charges for split type air conditioner with allied worksforoneindoorandoneoutdoorunit istobemountedon suitableAngle Iron support upto3.0Tonsplit/cassette type A/C.Each3746.53746.52.0FalseNoneNoneFalseNoneFalse7493.00
3600165131029None9.1.1Supplying, erecting, testing and commissioning of voltage stabilizersuitablefor170to270vinputandloadvariationfrom no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete - 3kVA CapacityEach4209.064209.062.0FalseNoneNoneFalseNoneFalse8418.120
17218095170000NoneNoneBuildingsBarur PHC(street lighting system)318859.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600166131030NonePWD SR 2023-24 Volume 6 It No-4.4.5Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3600167131030NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3600168131030NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3600169131030NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3600170131030NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3600171131030NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3600172131030NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3600173131030NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3600174131030NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3600175131030NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3600176131030NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3600177131030NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3600178131030NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
17218095170000NoneNoneBuildingsBarur PHC(CC Road)821594.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600179131031NonePWD SR 2023-24 V-3 Page No-9 It No-2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.923.6FalseNoneNoneFalseNoneFalse1752.9120
3600180131031NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.7108.0FalseNoneNoneFalseNoneFalse12711.60
3600181131031NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.09108.0FalseNoneNoneFalseNoneFalse14049.720
3600182131031NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.28108.0FalseNoneNoneFalseNoneFalse63426.240
3600183131031NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3600184131031NoneCSR 2023-24 Vol-3, P. No. 26,It. No. 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum3170.63170.654.0FalseNoneNoneFalseNoneFalse171212.40
3600185131031NonePWDSR2023-24 V-3 Page No-51 It No-6.6Construction of un-reinforced plain cement concrete pavementusing RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedureand thickness as per design, over a prepared sub base. Thesuperplastisiser confirming to IS 9103-1999 Reaffirmed-2008,Coarse aggregates and Fine aggregate confirming to IS:383-2016,transported to site, laid in approved fixed side form work (steelchannel, laying and fixing of 125 micron thick polythene film,wedges, steel plates including levelling the form work). Spreadingthe concrete with shovels, rackers and compacted using needle,suitable plate vibrator and finished in a continuous operation Including provision of separation membrane and Hessian clothfinishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification& direction of Engineer incharge of the workCum8392.988392.9854.0FalseNoneNoneFalseNoneFalse453220.920
17218095170000NoneNoneBuildingsBarur PHC(Compound wall)3658914.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600186131032None1.5Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.46194.87FalseNoneNoneFalseNoneFalse72191.54020
3600187131032None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3743.06FalseNoneNoneFalseNoneFalse319521.13220
3600188131032None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenanceCum8412.768412.7624.3FalseNoneNoneFalseNoneFalse204430.0680
3600189131032None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Cum13242.3113242.3144.5FalseNoneNoneFalseNoneFalse589282.7950
3600190131032None2.11ASupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne110837.22110837.228.36FalseNoneNoneFalseNoneFalse926599.15920
3600191131032None6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum9873.599873.5974.87FalseNoneNoneFalseNoneFalse739235.68330
3600192131032None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.671144.03FalseNoneNoneFalseNoneFalse525876.27010
3600193131032None8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Set of 2 Nos193.28193.281144.03FalseNoneNoneFalseNoneFalse221118.11840
3600194131032NonePWD Volume- 2 SR 2023-24 Page No-84 It No-11.25.Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kg168.5168.5360.0FalseNoneNoneFalseNoneFalse60660.00
17218095170000NoneNoneBuildingsBarur PHC(Borewell)419515.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600195131033NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3600196131033NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depthRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3600197131033NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3600198131033NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3600199131033NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.Rmtr2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3600200131033NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsRmtr681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3600201131033NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3600202131033NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3600203131033None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3600204131033NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" Each34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3600205131033NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3600206131033NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3600207131033NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3600208131033NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3600209131033NoneV-5P156I13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3600210131033NoneEleSrP No 12 2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)Rmtr121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3600211131033NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3600212131033NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3600213131033NoneEle SrP No 44,I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeEach361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3600214131033NoneEle rP No 47No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralEach2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3600215131033NoneEle SP No 44,INo 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeEach2230.292230.291.0FalseNoneNoneFalseNoneFalse2230.290
3600216131033NoneEleSr No 48,I No.6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Each495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
17218095170000NoneNoneBuildingsBarur PHC(RWH)53000.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600217131034NoneV-1page5itm1.4.Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.846.79FalseNoneNoneFalseNoneFalse2035.91360
3600218131034NoneV-1PAGE5ITM1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.96.79FalseNoneNoneFalseNoneFalse2178.9110
3600219131034NoneV-2P175I17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.Each1391.41391.428.0FalseNoneNoneFalseNoneFalse38959.20
3600220131034NoneV-2P175I17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.51241.51.13FalseNoneNoneFalseNoneFalse1402.8950
3600221131034NoneV-2P175I17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.51469.50.57FalseNoneNoneFalseNoneFalse837.6150
3600222131034NoneV-2P175I17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.91476.90.57FalseNoneNoneFalseNoneFalse841.8330
3600223131034NoneV-2P175I17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.Cum1659.01659.00.57FalseNoneNoneFalseNoneFalse945.630
3600224131034NoneV-2P177I17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1449.61449.64.0FalseNoneNoneFalseNoneFalse5798.40
17218095170000NoneNoneBuildingsBarur PHC NURSE QTRS (Civil Works)3682939.99
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600225131035NoneV-3 P.NO 7 IT.NO 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle Sqm486.92486.92300.0FalseNoneNoneFalseNoneFalse146076.00
3600226131035NoneV-1 P.NO 8 IT.NO 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Cum117.71117.7190.0FalseNoneNoneFalseNoneFalse10593.90
3600227131035NoneV-1 p.NO 8 IT.NO 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Cum126.38126.3861.03FalseNoneNoneFalseNoneFalse7712.97140
3600228131035NoneV-1 p.no 8 IT.NO 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Cum449.76449.7626.15FalseNoneNoneFalseNoneFalse11761.2240
3600229131035NoneV-3 P.NO 3 IT.NO ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) Cum167.27167.2756.15FalseNoneNoneFalseNoneFalse9392.21050
3600230131035NoneV-2 P.NO 5 IT.NO 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Sqm146.21146.21139.0FalseNoneNoneFalseNoneFalse20323.190
3600231131035NoneV-1 P.NO 7 IT.NO 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum329.58329.5861.03FalseNoneNoneFalseNoneFalse20114.26740
3600232131035NoneV-1 P.NO 7 IT.NO 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum587.29587.2960.8FalseNoneNoneFalseNoneFalse35707.2320
3600233131035NoneV-1 P.NO 15 IT.NO 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Cum7420.387420.3825.88FalseNoneNoneFalseNoneFalse192039.43440
3600234131035NoneV-1 P.NO 15 IT.NO 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8412.778412.7711.1FalseNoneNoneFalseNoneFalse93381.7470
3600235131035NoneV-1 P.NO 15 IT.NO 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PEDESTAL Cum8568.568568.5611.77FalseNoneNoneFalseNoneFalse100851.95120
3600236131035NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum14413.4214413.429.06FalseNoneNoneFalseNoneFalse130585.58520
3600237131035NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM Cum12717.7212717.726.15FalseNoneNoneFalseNoneFalse78213.9780
3600238131035NoneV-1 P.N 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates STAIRCASE GROUND FLOOR Cum12293.812293.82.38FalseNoneNoneFalseNoneFalse29259.2440
3600239131035NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAMS GROUND FLOOR Cum13565.5713565.575.42FalseNoneNoneFalseNoneFalse73525.38940
3600240131035NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF SLAB GROUND FLOOR Cum12717.7212717.7214.11FalseNoneNoneFalseNoneFalse179447.02920
3600241131035NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LINTELS GROUND FLOOR Cum13565.5713565.571.67FalseNoneNoneFalseNoneFalse22654.50190
3600242131035NoneV-1 P.NO 15 IT.NO 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Cum11169.1611169.161.27FalseNoneNoneFalseNoneFalse14184.83320
3600243131035NoneV-3 P.NO 117 IT.NO 15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy No252.76252.764.0FalseNoneNoneFalseNoneFalse1011.040
3600244131035NoneV-2 P.NO 9 IT.NO 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum7915.987915.981.33FalseNoneNoneFalseNoneFalse10528.25340
3600245131035NoneV-1 P.NO 18 IT.NO 2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification t110837.23110837.236.15FalseNoneNoneFalseNoneFalse681648.96450
3600246131035Nonesr-18-19 P.NO14 IT.NO 4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS Rmtr38.9438.9426.22FalseNoneNoneFalseNoneFalse1021.00680
3600247131035NoneData RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. Rmtr86.1486.1426.22FalseNoneNoneFalseNoneFalse2258.59080
3600248131035NoneV-2 P.NO 14 IT.NO 6.32Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm9873.69873.640.15FalseNoneNoneFalseNoneFalse396425.040
3600249131035NoneV-2 P.NO 14 IT.NO 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1209.271209.2732.25FalseNoneNoneFalseNoneFalse38998.95750
3600250131035NoneV-2 P.NO 100 IT.NO 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum122431.79122431.790.19FalseNoneNoneFalseNoneFalse23262.04010
3600251131035NoneV-2 P.NO 105 IT.NO 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. No1258.831258.834.0FalseNoneNoneFalseNoneFalse5035.320
3600252131035NoneV-2 P.NO 107 IT.NO 12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. No1303.431303.434.0FalseNoneNoneFalseNoneFalse5213.720
3600253131035NoneV-2 P.NO 107 IT.NO 12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. No1226.611226.614.0FalseNoneNoneFalseNoneFalse4906.440
3600254131035NoneV-2 P.NO 107 IT.NO 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete" No293.65293.654.0FalseNoneNoneFalseNoneFalse1174.60
3600255131035NoneV-2 P.NO 107 IT.NO 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete No161.07161.074.0FalseNoneNoneFalseNoneFalse644.280
3600256131035NoneV-2 P.NO 107 IT.NO 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms No68.1568.154.0FalseNoneNoneFalseNoneFalse272.60
3600257131035NoneV-2 P.NO 108 IT.NO 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) No340.73340.734.0FalseNoneNoneFalseNoneFalse1362.920
3600258131035NoneV-2 P.NO 69 IT.NO 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm No74.3474.3424.0FalseNoneNoneFalseNoneFalse1784.160
3600259131035NoneXI, 18-19 SR, 309 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. Rmtr15.015.019.35FalseNoneNoneFalseNoneFalse290.250
3600260131035NoneV-2 P.NO 106 IT.NO 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Sqm4115.964115.967.88FalseNoneNoneFalseNoneFalse32433.76480
3600261131035NoneV-2 (CPWD) P.NO 542 IT.NO 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick Sqm4317.924317.923.15FalseNoneNoneFalseNoneFalse13601.4480
3600262131035NoneV-2 (CPWD) P.NO 541 IT.NO 26.86.2Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).26.86.2 Frame size 45 x 85 mm Rmtr869.78869.789.9FalseNoneNoneFalseNoneFalse8610.8220
3600263131035NoneV-2 P.NO 109 IT.NO 12.87Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm8116.698116.6911.34FalseNoneNoneFalseNoneFalse92043.26460
3600264131035NoneV-2 P.NO 109 IT.NO 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7085.857085.851.08FalseNoneNoneFalseNoneFalse7652.7180
3600265131035NoneV-2 P.NO 110 IT.NO 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg208.16208.16215.41FalseNoneNoneFalseNoneFalse44839.74560
3600266131035NoneV-2 P.NO 81 IT.NO 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FOR WATER TANK STAND Kg182.14182.14102.75FalseNoneNoneFalseNoneFalse18714.8850
3600267131035NoneV-2 P.NO 41 IT.NO 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) Sqm386.57386.57434.01FalseNoneNoneFalseNoneFalse167775.24570
3600268131035NoneV-2 P.NO 43 IT.NO 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm261.43261.4349.3FalseNoneNoneFalseNoneFalse12888.4990
3600269131035NoneV-2 P.NO 50 IT.NO 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm123.9123.9483.31FalseNoneNoneFalseNoneFalse59882.1090
3600270131035NoneV-2 P.NO 41 IT.NO 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Outside) Sqm432.42432.42218.46FalseNoneNoneFalseNoneFalse94466.47320
3600271131035NoneV-2 P.NO 42 IT.NO 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm438.61438.6114.02FalseNoneNoneFalseNoneFalse6149.31220
3600272131035NoneP.NO118,18-19 SR ,IT.NO 15.36KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) Rmtr38.7838.78301.69FalseNoneNoneFalseNoneFalse11699.53820
3600273131035NoneP.NO 70,18-19 SR,IT.NO 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. Sqm270.18270.185.0FalseNoneNoneFalseNoneFalse1350.90
3600274131035NoneV-2 P.NO 54 IT.NO 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr64.4364.43166.05FalseNoneNoneFalseNoneFalse10698.60150
3600275131035NoneV-2 P.NO 61 IT.NO 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm Sqm1455.831455.8347.9FalseNoneNoneFalseNoneFalse69734.2570
3600276131035NoneV-2 P.NO 63 IT.NO 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sqm3055.383055.3826.68FalseNoneNoneFalseNoneFalse81517.53840
3600277131035NoneV-2,P.NO 65,IT.NO 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. Sqm2044.352044.355.46FalseNoneNoneFalseNoneFalse11162.1510
3600278131035NoneV-2,P.NO 41,IT.NO 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm365.51365.5140.97FalseNoneNoneFalseNoneFalse14974.94470
3600279131035NoneV-2,P.NO 60,IT.NO 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1101.481101.487.3FalseNoneNoneFalseNoneFalse8040.8040
3600280131035NoneV-2 P.NO 65 IT.NO 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1795.321795.3240.97FalseNoneNoneFalseNoneFalse73554.26040
3600281131035NoneV-2 P.NO 83 IT.NO 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg700.04700.04337.83FalseNoneNoneFalseNoneFalse236494.51320
3600282131035NoneV-2 P.NO 48 IT.NO 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm157.36157.36483.31FalseNoneNoneFalseNoneFalse76053.66160
3600283131035NoneV-2 P.NO 45 IT.NO 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm193.29193.29196.61FalseNoneNoneFalseNoneFalse38002.74690
3600284131035NoneV-2 P.NO 45 IT.NO 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops Sqm350.64350.6421.85FalseNoneNoneFalseNoneFalse7661.4840
3600285131035NoneV-2 P.NO 47 IT.NO 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm61.9561.956.21FalseNoneNoneFalseNoneFalse384.70950
3600286131035NoneV-2 P.NO 48 IT.NO 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm142.49142.496.21FalseNoneNoneFalseNoneFalse884.86290
3600287131035NoneV-2 P.NO 47 IT.NO 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm65.6765.6718.9FalseNoneNoneFalseNoneFalse1241.1630
3600288131035NoneV-2 P.NO 46 IT.NO 8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade.Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brandandmanufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeas per specifications and as per directions of Engineer-in-charge. Sqm170.99170.9918.9FalseNoneNoneFalseNoneFalse3231.7110
3600289131035NoneV-2 P.NO 75 IT.NO 11.5.1Providing and fixing 1mm thick M.S.steel garage door with frame and diagonal braces of size 40x40x6 mm angle Iron 3.15mm thick M.S.Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications. Sqm5548.255548.252.1FalseNoneNoneFalseNoneFalse11651.3250
3600290131035Nonedata rateProviding & laying Screed Concreete using 12mm & down size graded granite/trap metal,average thickness of 7.50cms including finishing etc complete as per specification with all lead & lift as directed by Engineer incharge.(Data Rate) - With all lead and lifts etc., complete as per specification and as per the directions of the Engineer-In-Charge of the work. Sqm585.28585.28139.0FalseNoneNoneFalseNoneFalse81353.920
3600291131035NoneV-2 P.NO 26 IT.NO 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm703.76703.768.4FalseNoneNoneFalseNoneFalse5911.5840
3600292131035NoneV-5 P.NO 34 IT.NO 3713PVC pipes of 6 Kg/cm2 for 110mm(1.894) Rmtr443.57443.5760.0FalseNoneNoneFalseNoneFalse26614.20
17218095170000NoneNoneBuildingsBarur PHC NUSE QTRS (Internal WS AND SANITARY)276216.78
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600293131036NoneV-2 P.NO 28 IT.NO 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Rmtr113.99113.9910.0FalseNoneNoneFalseNoneFalse1139.90
3600294131036NoneV-5 P.NO 187 IT.NO T090Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines Rmtr213.38213.3810.0FalseNoneNoneFalseNoneFalse2133.80
3600295131036NoneV-5 P.NO 34 IT.NO 3711PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Rmtr337.73337.7340.0FalseNoneNoneFalseNoneFalse13509.20
3600296131036NoneV-5 P.NO 34 IT.NO 3713PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Rmtr630.94630.9435.0FalseNoneNoneFalseNoneFalse22082.90
3600297131036NoneV-2 P.NO 119 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter Rmtr244.08244.0815.0FalseNoneNoneFalseNoneFalse3661.20
3600298131036NoneV-2 P.NO 119 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter Rmtr360.55360.5510.0FalseNoneNoneFalseNoneFalse3605.50
3600299131036NoneV-5 P.NO 34 IT.NO 3711PVC pipe - OD 75mm and 6 Kg/sqcm - (Shaft Drainage) Rmtr337.01337.0120.0FalseNoneNoneFalseNoneFalse6740.20
3600300131036NoneV-5 P.NO 34 IT.NO 3713PVC pipe - OD 110mm and 6 Kg/sqcm - (Shaft Drainage) Rmtr630.94630.9420.0FalseNoneNoneFalseNoneFalse12618.80
3600301131036NoneV-2 P.NO 128 IT.NO 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. No1511.581511.582.0FalseNoneNoneFalseNoneFalse3023.160
3600302131036NoneV-2 P.NO 116 IT.NO 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter No345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3600303131036NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. No6891.326891.321.0FalseNoneNoneFalseNoneFalse6891.320
3600304131036NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. No614.54614.541.0FalseNoneNoneFalseNoneFalse614.540
3600305131036NoneV-2 P.NO 123 IT.NO 14.3Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required No7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3600306131036NoneV-2 P.NO 126 IT.NO14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm No5986.855986.852.0FalseNoneNoneFalseNoneFalse11973.70
3600307131036NoneV-2 P.NO A-14 IT.NO 91C.P. Brass stop cock (concealed) 15 mm No650.48650.482.0FalseNoneNoneFalseNoneFalse1300.960
3600308131036NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps No3818.63818.61.0FalseNoneNoneFalseNoneFalse3818.60
3600309131036NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia Rmtr382.85382.8520.0FalseNoneNoneFalseNoneFalse7657.00
3600310131036NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." GROUND FLOOR 20 mm dia Rmtr469.58469.5820.0FalseNoneNoneFalseNoneFalse9391.60
3600311131036NoneV-2 P.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." GROUND FLOOR 25 mm dia Rmtr591.0591.025.0FalseNoneNoneFalseNoneFalse14775.00
3600312131036NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm dia Rmtr690.12690.1210.0FalseNoneNoneFalseNoneFalse6901.20
3600313131036NoneV-2 P.NO 120 IT.NO 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)" External & Shafts & Terrace 40mm DWS Rmtr591.0591.045.0FalseNoneNoneFalseNoneFalse26595.00
3600314131036NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)" External & Shafts & Terrace 50mm DWS Rmtr893.32893.3215.0FalseNoneNoneFalseNoneFalse13399.80
3600315131036NoneV-2,A-13,IT.NO 66Brass bib-cock 15 mm dia No354.35354.354.0FalseNoneNoneFalseNoneFalse1417.40
3600316131036NoneV-2 IT.NO 13.34KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. (For 1000 litre capacity) Specification No.KBS 13.22No11.1511.151000.0FalseNoneNoneFalseNoneFalse11150.00
3600317131036NoneMarket RateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards Ground Toilet 10Cms X 7.5Cms No371.7371.710.0FalseNoneNoneFalseNoneFalse3717.00
3600318131036NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) No177.0177.010.0FalseNoneNoneFalseNoneFalse1770.00
3600319131036NoneMarket RateDrilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 7.50 cms thick No154.58154.585.0FalseNoneNoneFalseNoneFalse772.90
3600320131036NoneMarket RateDrilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 10 cms thick No185.26185.265.0FalseNoneNoneFalseNoneFalse926.30
3600321131036NoneMarket RateAir Vent Cowel 75mm No413.0413.010.0FalseNoneNoneFalseNoneFalse4130.00
3600322131036NoneMarket RateAir Vent Cowel 110mm No590.0590.010.0FalseNoneNoneFalseNoneFalse5900.00
3600323131036NoneMarket RateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards No5664.05664.02.0FalseNoneNoneFalseNoneFalse11328.00
3600324131036NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). No2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3600325131036NoneMarket RateSupplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) No1996.561996.562.0FalseNoneNoneFalseNoneFalse3993.120
3600326131036NoneMarket RateProviding and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot. Each295.0295.05.0FalseNoneNoneFalseNoneFalse1475.00
3600327131036NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. c) 50mm diaNo3304.03304.02.0FalseNoneNoneFalseNoneFalse6608.00
3600328131036None8.3.1Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.No37498.037498.01.0FalseNoneNoneFalseNoneFalse37498.00
3600329131036NoneCPWD SR, V-2,377,1927Brass full way valve with C.I. wheel (screwed end) 25 mm diaEach442.5442.53.0FalseNoneNoneFalseNoneFalse1327.50
3600330131036NoneCPWD SR, V-2,377,1928Brass full way valve with C.I. wheel (screwed end) 32 mm diaEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3600331131036NoneCPWD SR, V-2,377,1929Brass full way valve with C.I. wheel (screwed end) 40 mm diaEach590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
17218095170000NoneNoneBuildingsBarur PHC NURSE QTRS(INERNAL ELECTRICAL)150783.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600332131037NoneIT.NO 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box Point333.29333.296.0FalseNoneNoneFalseNoneFalse1999.740
3600333131037NoneIT.NO 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box Point469.58469.587.0FalseNoneNoneFalseNoneFalse3287.060
3600334131037NoneIT.NO 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box Point687.65687.657.0FalseNoneNoneFalseNoneFalse4813.550
3600335131037NoneIT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way Each170.98170.989.0FalseNoneNoneFalseNoneFalse1538.820
3600336131037NoneIT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Each197.0197.01.0FalseNoneNoneFalseNoneFalse197.00
3600337131037NoneIT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Each219.3219.31.0FalseNoneNoneFalseNoneFalse219.30
3600338131037NoneIT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Each272.58272.583.0FalseNoneNoneFalseNoneFalse817.740
3600339131037NoneIT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Each323.38323.382.0FalseNoneNoneFalseNoneFalse646.760
3600340131037NoneIT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module Each216.83216.831.0FalseNoneNoneFalseNoneFalse216.830
3600341131037NoneIT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Moudule Each216.83216.831.0FalseNoneNoneFalseNoneFalse216.830
3600342131037NoneIT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Moudule Each289.93289.931.0FalseNoneNoneFalseNoneFalse289.930
3600343131037NoneIT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Moudule Each351.88351.883.0FalseNoneNoneFalseNoneFalse1055.640
3600344131037NoneIT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10Moudule Each426.22426.222.0FalseNoneNoneFalseNoneFalse852.440
3600345131037NoneIT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. Each126.38126.3828.0FalseNoneNoneFalseNoneFalse3538.640
3600346131037NoneIT.NO 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way. Each205.67205.674.0FalseNoneNoneFalseNoneFalse822.680
3600347131037NoneIT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. Each211.87211.8710.0FalseNoneNoneFalseNoneFalse2118.70
3600348131037NoneIT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Each442.32442.323.0FalseNoneNoneFalseNoneFalse1326.960
3600349131037NoneIT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch Each403.91403.913.0FalseNoneNoneFalseNoneFalse1211.730
3600350131037NoneIT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket Each292.4292.43.0FalseNoneNoneFalseNoneFalse877.20
3600351131037NoneIT.NO 3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3600352131037NoneIT.NO 13.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3600353131037NoneIT.NO 1.12Supplyin and Fixing Metal Fan Box with Round Hook. No144.96144.963.0FalseNoneNoneFalseNoneFalse434.880
3600354131037NoneITM 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick Rmtr81.7781.77160.0FalseNoneNoneFalseNoneFalse13083.20
3600355131037NoneITM 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick Rmtr96.6496.6470.0FalseNoneNoneFalseNoneFalse6764.80
3600356131037NoneITM 1.2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick Rmtr127.66127.6620.0FalseNoneNoneFalseNoneFalse2553.20
3600357131037NoneITM 1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 19/20mm dia 2mm thick Rmtr84.2584.2575.0FalseNoneNoneFalseNoneFalse6318.750
3600358131037NoneITM 1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 25mm dia 2mm thick Rmtr97.8897.8840.0FalseNoneNoneFalseNoneFalse3915.20
3600359131037NoneITM 1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 32mm dia 2.5mm thick Rmtr122.66122.6610.0FalseNoneNoneFalseNoneFalse1226.60
3600360131037NoneITM 2.5.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5) 1.5 sqmm Rmtr32.2132.2175.0FalseNoneNoneFalseNoneFalse2415.750
3600361131037NoneITM 2.5.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5) 2.5 sqmm Rmtr52.0452.04180.0FalseNoneNoneFalseNoneFalse9367.20
3600362131037NoneITM 2.5.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5) 4 sqmm Rmtr78.0678.0660.0FalseNoneNoneFalseNoneFalse4683.60
3600363131037NoneBSR-32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm Km125279.01125279.010.1FalseNoneNoneFalseNoneFalse12527.9010
3600364131037NoneBSR-31Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm Km20021.020021.00.1FalseNoneNoneFalseNoneFalse2002.10
3600365131037NoneSR 19-20 ITM 6.11Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm Each84.2584.254.0FalseNoneNoneFalseNoneFalse337.00
3600366131037NoneSR 19-20 ITM 6.6.2Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (hard) Rmtr126.38126.3860.0FalseNoneNoneFalseNoneFalse7582.80
3600367131037NoneITM 8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair Rmtr26.0226.0220.0FalseNoneNoneFalseNoneFalse520.40
3600368131037NoneITM8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. MCB DB Rmtr54.5254.5225.0FalseNoneNoneFalseNoneFalse1363.00
3600369131037NoneITM5.18.8Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 12 Way SP & NEach3771.523771.521.0FalseNoneNoneFalseNoneFalse3771.520
3600370131037NoneITM5.17.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP Each514.19514.1910.0FalseNoneNoneFalseNoneFalse5141.90
3600371131037NoneITM 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole Each6538.26538.21.0FalseNoneNoneFalseNoneFalse6538.20
3600372131037NoneITM 11.3Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w Each854.91854.916.0FalseNoneNoneFalseNoneFalse5129.460
3600373131037NoneITM 12.46Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Supplying & Fixing of 70-150 Watts lamp holder 2 Pin Each183.37183.378.0FalseNoneNoneFalseNoneFalse1466.960
3600374131037NoneITM11.11.3Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K Each184.61184.613.0FalseNoneNoneFalseNoneFalse553.830
3600375131037Noneitm11.11.5Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500KEach333.29333.291.0FalseNoneNoneFalseNoneFalse333.290
3600376131037NoneItm 11.11.7Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500KEach527.81527.812.0FalseNoneNoneFalseNoneFalse1055.620
3600377131037None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power SupplyNo64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3600378131037None6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1849.01849.02.0FalseNoneNoneFalseNoneFalse3698.00
3600379131037None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.Each3697.183697.183.0FalseNoneNoneFalseNoneFalse11091.540
3600380131037None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each151.15151.156.0FalseNoneNoneFalseNoneFalse906.90
3600381131037None13.10Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each211.86211.863.0FalseNoneNoneFalseNoneFalse635.580
3600382131037None13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.972.0FalseNoneNoneFalseNoneFalse1751.940
3600383131037None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, eEach1810.181810.181.0FalseNoneNoneFalseNoneFalse1810.180
3600384131037None13.4.1Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Single bracket 1.5 Mtr. Length Each1810.181810.181.0FalseNoneNoneFalseNoneFalse1810.180
3600385131037None13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.71200.711.0FalseNoneNoneFalseNoneFalse200.710
3600386131037None5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP Each915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3600387131037None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps Each298.59298.591.0FalseNoneNoneFalseNoneFalse298.590
3600388131037None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
17218095170000NoneNoneBuildingsHEMALAPUR PHC(Civil Works)19709674.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600389131038NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle100 Sqm486.93486.9320.0FalseNoneNoneFalseNoneFalse9738.60
3600390131038NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.71117.71222.09FalseNoneNoneFalseNoneFalse26142.21390
3600391131038NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.38126.38670.52FalseNoneNoneFalseNoneFalse84740.31760
3600392131038NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthCum449.76449.76167.63FalseNoneNoneFalseNoneFalse75393.26880
3600393131038NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)Cum167.27167.27100.0FalseNoneNoneFalseNoneFalse16727.00
3600394131038NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2570.14FalseNoneNoneFalseNoneFalse83354.4680
3600395131038NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57670.52FalseNoneNoneFalseNoneFalse220983.27640
3600396131038NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.29587.29143.97FalseNoneNoneFalseNoneFalse84552.14130
3600397131038NoneV-1page 15 itm2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.37123.48FalseNoneNoneFalseNoneFalse916267.28760
3600398131038NoneV-1page15 itm 2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Formwork, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregatesCum8412.768412.7694.25FalseNoneNoneFalseNoneFalse792902.630
3600399131038NoneV-1page16 itm 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum14413.4114413.4137.06FalseNoneNoneFalseNoneFalse534160.97460
3600400131038NoneV-1page15itm 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Formwork all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum7702.867702.866.96FalseNoneNoneFalseNoneFalse53611.90560
3600401131038NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/EpoxyNo252.76252.7630.0FalseNoneNoneFalseNoneFalse7582.80
3600402131038NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3600403131038NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - BuildingsTonne110837.22110837.2237.25FalseNoneNoneFalseNoneFalse4128686.4450
3600404131038None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBSRmtr38.9438.94111.0FalseNoneNoneFalseNoneFalse4322.340
3600405131038NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.Rmtr86.1486.14111.0FalseNoneNoneFalseNoneFalse9561.540
3600406131038NoneV-2PAGE 9 ITM5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7688.07688.017.19FalseNoneNoneFalseNoneFalse132156.720
3600407131038NoneV-2PAGE 14 ITM 6.32Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9873.599873.59199.58FalseNoneNoneFalseNoneFalse1970571.09220
3600408131038NoneV-2page 14 itm 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum1209.261209.2686.23FalseNoneNoneFalseNoneFalse104274.48980
3600409131038NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.79122431.790.99FalseNoneNoneFalseNoneFalse121207.47210
3600410131038NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.8214.0FalseNoneNoneFalseNoneFalse17623.480
3600411131038NoneV-2page 104 itm 12.51Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1314.581314.5814.0FalseNoneNoneFalseNoneFalse18404.120
3600412131038NoneV-2 page 105 itm 12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1226.611226.6114.0FalseNoneNoneFalseNoneFalse17172.540
3600413131038NoneV-2page 105 itm 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.6428.0FalseNoneNoneFalseNoneFalse8221.920
3600414131038NoneV-2page 105itm 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0728.0FalseNoneNoneFalseNoneFalse4509.960
3600415131038NoneV-2page105 itm 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1568.1514.0FalseNoneNoneFalseNoneFalse954.10
3600416131038NoneV-2page107itm12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)Nos340.73340.7328.0FalseNoneNoneFalseNoneFalse9540.440
3600417131038NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos74.3474.3484.0FalseNoneNoneFalseNoneFalse6244.560
3600418131038NoneXI page 18-19 SR313 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.Rmtr15.015.0105.8FalseNoneNoneFalseNoneFalse1587.00
3600419131038NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.964115.9641.21FalseNoneNoneFalseNoneFalse169618.71160
3600420131038NoneV-2page109 itm 12.87Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.6977.31FalseNoneNoneFalseNoneFalse627501.30390
3600421131038NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.846.48FalseNoneNoneFalseNoneFalse45916.24320
3600422131038NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg208.15208.152159.01FalseNoneNoneFalseNoneFalse449397.93150
3600423131038NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mmm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3600424131038NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs168.5168.5120.96FalseNoneNoneFalseNoneFalse20381.760
3600425131038NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)Sqm386.57386.571049.85FalseNoneNoneFalseNoneFalse405840.51450
3600426131038NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm261.43261.43531.95FalseNoneNoneFalseNoneFalse139067.68850
3600427131038NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm123.9123.91581.8FalseNoneNoneFalseNoneFalse195985.020
3600428131038NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)Sqm432.41432.411016.08FalseNoneNoneFalseNoneFalse439363.15280
3600429131038NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm438.61438.6129.15FalseNoneNoneFalseNoneFalse12785.48150
3600430131038None118page18-19 SR15.36Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )Rmtr36.5836.58800.0FalseNoneNoneFalseNoneFalse29264.00
3600431131038None18-19 SR0.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.Sqm254.88254.8820.0FalseNoneNoneFalseNoneFalse5097.60
3600432131038NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.Rmtr64.4364.43709.5FalseNoneNoneFalseNoneFalse45713.0850
3600433131038NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mmSqm1455.831455.83293.21FalseNoneNoneFalseNoneFalse426863.91430
3600434131038NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3600435131038NoneV-2page63 itm 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm3055.373055.37214.93FalseNoneNoneFalseNoneFalse656690.67410
3600436131038NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm365.51365.51891.34FalseNoneNoneFalseNoneFalse325793.68340
3600437131038NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.Sqm1101.471101.4729.98FalseNoneNoneFalseNoneFalse33022.07060
3600438131038NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1795.311795.31891.34FalseNoneNoneFalseNoneFalse1600231.61540
3600439131038NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg700.04700.04260.78FalseNoneNoneFalseNoneFalse182556.43120
3600440131038NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm157.35157.351581.8FalseNoneNoneFalseNoneFalse248896.230
3600441131038NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28762.06FalseNoneNoneFalseNoneFalse147290.95680
3600442131038NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm61.9561.9583.79FalseNoneNoneFalseNoneFalse5190.79050
3600443131038NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm142.49142.4983.79FalseNoneNoneFalseNoneFalse11939.23710
3600444131038NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6765.6798.89FalseNoneNoneFalseNoneFalse6494.10630
3600445131038NoneV-2page49itm 8.47Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm167.27167.2798.89FalseNoneNoneFalseNoneFalse16541.33030
3600446131038NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3600447131038NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm5548.245548.243.15FalseNoneNoneFalseNoneFalse17476.9560
3600448131038NoneLQRRoof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane. System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification. Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant. Sqm1593.01593.0633.5FalseNoneNoneFalseNoneFalse1009165.50
3600449131038NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specificationsSqm411.35411.3516.34FalseNoneNoneFalseNoneFalse6721.4590
3600450131038NoneV-2PAGE27ITM 7.40Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.Sqm2118.692118.6948.84FalseNoneNoneFalseNoneFalse103476.81960
3600451131038NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9326.329326.3220.24FalseNoneNoneFalseNoneFalse188764.71680
3600452131038NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.7244.58FalseNoneNoneFalseNoneFalse566955.95760
3600453131038NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13565.5613565.5630.15FalseNoneNoneFalseNoneFalse409001.6340
3600454131038NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.7287.68FalseNoneNoneFalseNoneFalse1115089.68960
3600455131038NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.724.32FalseNoneNoneFalseNoneFalse54940.55040
3600456131038NoneV1P16I2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Formwork all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.7213.25FalseNoneNoneFalseNoneFalse168509.790
3600457131038NoneITEM 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar dropsSqm350.64350.64254.02FalseNoneNoneFalseNoneFalse89069.57280
3600458131038None12.94.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thickSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
17218095170000NoneNoneBuildingsHEMALAPUR PHC(Internal WS AND SANITARY)1166957.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600459131039NoneV-2 P.NO 135 IT.NO 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Rmtr113.99113.9940.0FalseNoneNoneFalseNoneFalse4559.60
3600460131039NoneV-5 P.NO 187 IT.NO T090DProviding and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines Rmtr213.38213.3820.0FalseNoneNoneFalseNoneFalse4267.60
3600461131039NoneV-5 P.NO 34 IT.NO 3711Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Rmtr337.73337.7350.0FalseNoneNoneFalseNoneFalse16886.50
3600462131039NoneV-5 P.NO 34 IT.NO 3713Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Rmtr630.94630.94180.0FalseNoneNoneFalseNoneFalse113569.20
3600463131039NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter Rmtr244.08244.0825.0FalseNoneNoneFalseNoneFalse6102.00
3600464131039NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter Rmtr360.55360.5560.0FalseNoneNoneFalseNoneFalse21633.00
3600465131039NoneV-2 P.NO 128 IT.NO 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. No1511.581511.5820.0FalseNoneNoneFalseNoneFalse30231.60
3600466131039NoneV-2 P.NO 116 IT.NO 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter No345.68345.683.0FalseNoneNoneFalseNoneFalse1037.040
3600467131039NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. No6891.326891.323.0FalseNoneNoneFalseNoneFalse20673.960
3600468131039NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. No614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3600469131039NoneV-2 P.NO 123 IT.NO 14.3Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required No7192.47192.48.0FalseNoneNoneFalseNoneFalse57539.20
3600470131039NoneV-2 P.NO 178 IT.NO 20.44.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm No4394.734394.7310.0FalseNoneNoneFalseNoneFalse43947.30
3600471131039NoneV-2 P.NO 124 IT.NO14.4.4Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern No16193.7316193.734.0FalseNoneNoneFalseNoneFalse64774.920
3600472131039NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3600473131039NoneV-2 P.NO 126 IT.NO 14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm No5986.855986.852.0FalseNoneNoneFalseNoneFalse11973.70
3600474131039NoneV-2 P.NO A-14 IT.NO 91C.P. Brass stop cock (concealed) 15 mm No650.48650.4810.0FalseNoneNoneFalseNoneFalse6504.80
3600475131039NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps No3818.63818.65.0FalseNoneNoneFalseNoneFalse19093.00
3600476131039NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm diaRmtr382.85382.8560.0FalseNoneNoneFalseNoneFalse22971.00
3600477131039NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm diaRmtr469.58469.5850.0FalseNoneNoneFalseNoneFalse23479.00
3600478131039NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3600479131039NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3600480131039NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3600481131039NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3600482131039NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3600483131039NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS Rmtr893.32893.3225.0FalseNoneNoneFalseNoneFalse22333.00
3600484131039NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS Rmtr591.0591.0150.0FalseNoneNoneFalseNoneFalse88650.00
3600485131039NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS Rmtr1734.61734.623.0FalseNoneNoneFalseNoneFalse39895.80
3600486131039NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS Rmtr893.32893.3225.0FalseNoneNoneFalseNoneFalse22333.00
3600487131039NoneCPWD SR, V-2,P.NO 109,IT.NO 1927Brass full way valve with C.I. wheel (screwed end) 25 mm dia Each442.5442.510.0FalseNoneNoneFalseNoneFalse4425.00
3600488131039NoneCPWD SR, V-2, P.NO 110,IT.NO 1928Brass full way valve with C.I. wheel (screwed end) 32 mm dia Each489.7489.75.0FalseNoneNoneFalseNoneFalse2448.50
3600489131039NoneCPWD SR, V-2, P.NO 111,IT.NO 1929Brass full way valve with C.I. wheel (screwed end) 40 mm dia Each590.0590.05.0FalseNoneNoneFalseNoneFalse2950.00
3600490131039NoneCPWD SR, V-2,P.NO 112,IT.NO 1930Brass full way valve with C.I. wheel (screwed end) 50 mm dia Each737.5737.52.0FalseNoneNoneFalseNoneFalse1475.00
3600491131039NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia No354.35354.3515.0FalseNoneNoneFalseNoneFalse5315.250
3600492131039NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. No11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
3600493131039NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. 100 Liter capacity No37498.0437498.042.0FalseNoneNoneFalseNoneFalse74996.080
3600494131039NoneMarket RateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards Ground Toilet 10Cms X 7.5Cms No371.7371.745.0FalseNoneNoneFalseNoneFalse16726.50
3600495131039NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) No177.0177.045.0FalseNoneNoneFalseNoneFalse7965.00
3600496131039NoneMarket RateAir Vent Cowel 75mm No413.0413.020.0FalseNoneNoneFalseNoneFalse8260.00
3600497131039NoneMarket RateAir Vent Cowel 110mm No590.0590.020.0FalseNoneNoneFalseNoneFalse11800.00
3600498131039NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. brass pillar taps with C.I. /M.S. brackets, 32 mm C.P. brass waste of standard pattern, including Brass stop cock, 32mm PVC connection painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification as directed by the Engineer in charge. CNS-WHT-705, make Jaguar/hindware/Cera No5664.05664.020.0FalseNoneNoneFalseNoneFalse113280.00
3600499131039NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). No2183.02183.08.0FalseNoneNoneFalseNoneFalse17464.00
3600500131039NoneMarket RateSupplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) No1996.561996.564.0FalseNoneNoneFalseNoneFalse7986.240
3600501131039NoneMarket RateProviding and fixing in position Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-087FT) ( Jaguar make or Equalent ) including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.No1147.91147.910.0FalseNoneNoneFalseNoneFalse11479.00
3600502131039NoneMarket RateProviding and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot. -do- 10cms x 7.5 cms Each295.0295.010.0FalseNoneNoneFalseNoneFalse2950.00
3600503131039NoneMarket RateSupplying, fixing, testing and commissioning of single sink with large basin for Hospital use. Pedal-controlled faucet and button-controlled soap dispenser. The basin is supplied complete with drain, siphon, flexible connection to the water mains and plugs for wall mounting.No25370.025370.01.0FalseNoneNoneFalseNoneFalse25370.00
3600504131039NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. No767.0767.065.0FalseNoneNoneFalseNoneFalse49855.00
3600505131039NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3600506131039NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia No3304.03304.02.0FalseNoneNoneFalseNoneFalse6608.00
17218095170000NoneNoneBuildingsHEMALAPUR PHC(EXTERNAL WS & SANITARY)1181322.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600507131040NoneV-1,P.NO 6,IT.NO 1.5Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum370.46370.46278.0FalseNoneNoneFalseNoneFalse102987.880
3600508131040NoneV-1 P.NO 7 IT.NO 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum329.57329.57278.0FalseNoneNoneFalseNoneFalse91620.460
3600509131040NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). - do - 160 mm dia Rmtr713.66713.66350.0FalseNoneNoneFalseNoneFalse249781.00
3600510131040NoneV-5,P.NO 134,IT.NO- 10.2.5Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). - do - 200 mm dia Rmtr1029.611029.6160.0FalseNoneNoneFalseNoneFalse61776.60
3600511131040NoneV-5 P.NO 134 IT.NO 10.2.6Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). - do - 250 mm dia Rmtr1578.491578.4910.0FalseNoneNoneFalseNoneFalse15784.90
3600512131040NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3600513131040NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3600514131040NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3600515131040NoneMARKET RATEProviding stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms No330.4330.425.0FalseNoneNoneFalseNoneFalse8260.00
3600516131040NoneIT.NO 11.39KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22 m internal dia at bottom, 1.68 m deep and 0.56m dia at top, with table moulded and non modular bricks of class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and down size granite metal and making necessary channel in cement concrete M 15 with 20mm and down size granite metal, finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter confirming to IS :12592, total weight length of cover and frame to be not less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 No36325.036325.01.0FalseNoneNoneFalseNoneFalse36325.00
3600517131040NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3600518131040NoneMarket RateSupply and fixing of GM ball cock with copper float(High pressure float)of ISI or BIS Standardsand & fixed on to the inlet pipe at the underground sump tank & OHT. No5900.05900.05.0FalseNoneNoneFalseNoneFalse29500.00
3600519131040NoneMARKET RATESupplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (DOMESTIC)2.00 HPNos41300.041300.02.0FalseNoneNoneFalseNoneFalse82600.00
17218095170000NoneNoneBuildingsHEMALAPUR PHC(INETRNAL ELECTRICAL)1238058.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600520131041NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch Point333.29333.2936.0FalseNoneNoneFalseNoneFalse11998.440
3600521131041NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch Pack469.58469.5845.0FalseNoneNoneFalseNoneFalse21131.10
3600522131041NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch Point687.65687.6560.0FalseNoneNoneFalseNoneFalse41259.00
3600523131041NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint838.8838.84.0FalseNoneNoneFalseNoneFalse3355.20
3600524131041NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way Each170.89170.8920.0FalseNoneNoneFalseNoneFalse3417.80
3600525131041NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Each197.0197.010.0FalseNoneNoneFalseNoneFalse1970.00
3600526131041NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Each219.3219.310.0FalseNoneNoneFalseNoneFalse2193.00
3600527131041NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way Each272.58272.5822.0FalseNoneNoneFalseNoneFalse5996.760
3600528131041NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Each323.38323.3825.0FalseNoneNoneFalseNoneFalse8084.50
3600529131041NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module Each199.48199.4820.0FalseNoneNoneFalseNoneFalse3989.60
3600530131041NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Each216.83216.8310.0FalseNoneNoneFalseNoneFalse2168.30
3600531131041NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module Each289.93289.9310.0FalseNoneNoneFalseNoneFalse2899.30
3600532131041NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Each351.88351.8822.0FalseNoneNoneFalseNoneFalse7741.360
3600533131041NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module Each426.22426.2225.0FalseNoneNoneFalseNoneFalse10655.50
3600534131041NonePWD ELE SR V-27 IT.NO 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch Each126.38126.38216.0FalseNoneNoneFalseNoneFalse27298.080
3600535131041NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3600536131041NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket Each211.87211.8772.0FalseNoneNoneFalseNoneFalse15254.640
3600537131041NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Each442.32442.3220.0FalseNoneNoneFalseNoneFalse8846.40
3600538131041NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch Each223.02223.027.0FalseNoneNoneFalseNoneFalse1561.140
3600539131041NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3600540131041NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket Each292.4292.422.0FalseNoneNoneFalseNoneFalse6432.80
3600541131041NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. No144.96144.9620.0FalseNoneNoneFalseNoneFalse2899.20
3600542131041NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick Rmtr81.7781.77450.0FalseNoneNoneFalseNoneFalse36796.50
3600543131041NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick Rmtr96.6496.64650.0FalseNoneNoneFalseNoneFalse62816.00
3600544131041NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick Rmtr127.62127.6280.0FalseNoneNoneFalseNoneFalse10209.60
3600545131041NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick Rmtr84.2584.25180.0FalseNoneNoneFalseNoneFalse15165.00
3600546131041NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. Rmtr97.8897.88260.0FalseNoneNoneFalseNoneFalse25448.80
3600547131041NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick Rmtr122.66122.6632.0FalseNoneNoneFalseNoneFalse3925.120
3600548131041NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm Rmtr32.2132.21300.0FalseNoneNoneFalseNoneFalse9663.00
3600549131041NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm Rmtr52.0452.04940.0FalseNoneNoneFalseNoneFalse48917.60
3600550131041NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm Rmtr78.0678.06400.0FalseNoneNoneFalseNoneFalse31224.00
3600551131041NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm Rmtr113.99113.99280.0FalseNoneNoneFalseNoneFalse31917.20
3600552131041NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3600553131041NonePWD ELE SR V-6,IT.NO 5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N Each2308.262308.261.0FalseNoneNoneFalseNoneFalse2308.260
3600554131041NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP Each514.19514.1934.0FalseNoneNoneFalseNoneFalse17482.460
3600555131041NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3600556131041NonePWD ELE SR V-6,IT.NO 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps DP Each915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3600557131041NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole Each6538.26538.26.0FalseNoneNoneFalseNoneFalse39229.20
3600558131041NonePWD ELE SR V-6,IT.NO5.20.2Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32 -40 Amps 2 pole Each5648.65648.61.0FalseNoneNoneFalseNoneFalse5648.60
3600559131041NonePWD ELE SR V-6 BSR-32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm Km258542.13258542.130.2FalseNoneNoneFalseNoneFalse51708.4260
3600560131041NonePWD ELE SR V-6,IT.NO BSR-31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm Km29298.6329298.630.2FalseNoneNoneFalseNoneFalse5859.7260
3600561131041NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia Each144.96144.968.0FalseNoneNoneFalseNoneFalse1159.680
3600562131041NonePWD ELE SR V-6,IT.NO 6.9.2Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 50mm Rmtr470.82470.8210.0FalseNoneNoneFalseNoneFalse4708.20
3600563131041NoneSR 19-20 IT.NO 6.6.2Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (hard) Rmtr126.38126.3890.0FalseNoneNoneFalseNoneFalse11374.20
3600564131041NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel Each39.6539.658.0FalseNoneNoneFalseNoneFalse317.20
3600565131041NonePWD ELE SR V-6,IT.NO 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 3CX2.5 Sq mm Rmtr140.01140.0150.0FalseNoneNoneFalseNoneFalse7000.50
3600566131041NonePWD ELE SR V-6 IT.NO2.6.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 3CX4 Sq mm Rmtr206.91206.91100.0FalseNoneNoneFalseNoneFalse20691.00
3600567131041NoneSR 19-20 IT.NO 6.1Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. No3716.633716.634.0FalseNoneNoneFalseNoneFalse14866.520
3600568131041NoneSR 19-20 IT.NO 6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip Rmtr92.9392.9330.0FalseNoneNoneFalseNoneFalse2787.90
3600569131041NonePWD ELE SR V-6,IT.NO 6.3.4Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 50x6mm GI strip Rmtr241.61241.6120.0FalseNoneNoneFalseNoneFalse4832.20
3600570131041NonePWD ELE SR V-6,IT.NO 11.3.2Supplying of .feet PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 wEach854.91854.9170.0FalseNoneNoneFalseNoneFalse59843.70
3600571131041NonePWD ELE SR V-6,IT.NO 11.6.2Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' / 1' x 4' 34 -36wattNo7307.627307.6212.0FalseNoneNoneFalseNoneFalse87691.440
3600572131041NonePWD ELE SR V-6,IT.NO 11.11.3Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500KNo184.61184.618.0FalseNoneNoneFalseNoneFalse1476.880
3600573131041NonePWD ELE SR V-6,IT.NO 11.11.5Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K No333.29333.2913.0FalseNoneNoneFalseNoneFalse4332.770
3600574131041NonePWD ELE SR V-6,IT.NO 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply No64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3600575131041NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1848.591848.5910.0FalseNoneNoneFalseNoneFalse18485.90
3600576131041NonePWD ELE SR V-6,IT.NO 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Each3697.183697.1820.0FalseNoneNoneFalseNoneFalse73943.60
3600577131041NonePWD ELE SR V-6,IT.NO 6.5.1Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep Each3087.593087.593.0FalseNoneNoneFalseNoneFalse9262.770
3600578131041NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each151.16151.1681.0FalseNoneNoneFalseNoneFalse12243.960
3600579131041NonePWD ELE SR V-6,IT.NO 13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each211.87211.8723.0FalseNoneNoneFalseNoneFalse4873.010
3600580131041NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Each875.97875.9710.0FalseNoneNoneFalseNoneFalse8759.70
3600581131041NonePWD ELE SR V-6,IT.NO 11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25wattsNo3004.583004.584.0FalseNoneNoneFalseNoneFalse12018.320
3600582131041NonePWD ELE SR V-6,IT.NO 13.2.2Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe Each1604.511604.514.0FalseNoneNoneFalseNoneFalse6418.040
3600583131041NonePWD ELE SR V-6,IT.NO 13.5Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing V/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Each200.72200.724.0FalseNoneNoneFalseNoneFalse802.880
3600584131041NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG Sq CM0.530.53110000.0FalseNoneNoneFalseNoneFalse58300.00
3600585131041NonePWD ELE SR V-6,IT.NO 5.40.1Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips Rmtr3054.143054.144.0FalseNoneNoneFalseNoneFalse12216.560
3600586131041NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm Rmtr377.9377.98.0FalseNoneNoneFalseNoneFalse3023.20
3600587131041NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel Rmtr936.68936.688.0FalseNoneNoneFalseNoneFalse7493.440
3600588131041NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3600589131041NonePWD ELE SR V-6,IT.NO 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN Each3771.523771.523.0FalseNoneNoneFalseNoneFalse11314.560
3600590131041NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP Each3826.033826.033.0FalseNoneNoneFalseNoneFalse11478.090
3600591131041NonePWD ELE SR V-6,IT.NO 5.11.2Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. 100Amps Each8784.518784.511.0FalseNoneNoneFalseNoneFalse8784.510
3600592131041NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3600593131041NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3600594131041NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3600595131041NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery Kvar594.72594.7210.0FalseNoneNoneFalseNoneFalse5947.20
3600596131041NonePWD ELE SR V-6,IT.NO 5.44.1Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. 300mmx300mmx214mmEach5590.375590.371.0FalseNoneNoneFalseNoneFalse5590.370
3600597131041NonePWD ELE SR V-6,IT.NO 5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter. Each7068.57068.51.0FalseNoneNoneFalseNoneFalse7068.50
3600598131041NonePWD ELE SR V-6,IT.NO 3.6.12TELEPHONE & NETWORKING RJ45/ I.O. outlet Each417.54417.5411.0FalseNoneNoneFalseNoneFalse4592.940
3600599131041NonePWD ELE SR V-6,IT.NO 3.6.11Telephone socket Each193.28193.288.0FalseNoneNoneFalseNoneFalse1546.240
3600600131041NonePWD ELE SR V-6,IT.NO 8.1Supplying and drawing UTP-CAT 6E LAN cable. Rmtr47.0847.08300.0FalseNoneNoneFalseNoneFalse14124.00
3600601131041NonePWD ELE SR V-6,IT.NO 8.10.1Supplying & Fixing of I/O Socket with back box Single I/O Each607.11607.1111.0FalseNoneNoneFalseNoneFalse6678.210
3600602131041NonePWD ELE SR V-6,IT.NO 8.4.1Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 4U with 450mm depth Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3600603131041NonePWD ELE SR V-6,IT.NO 8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 Switch Each7979.167979.161.0FalseNoneNoneFalseNoneFalse7979.160
3600604131041NonePWD ELE SR V-6,IT.NO 8.11.1Supplying & fixing of .mtrs. Cat 6Patch Cable. 2Mtr Each318.42318.4211.0FalseNoneNoneFalseNoneFalse3502.620
3600605131041NonePWD ELE SR V-6,IT.NO 8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3600606131041NonePWD ELE SR V-6,IT.NO 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. Rmtr26.0226.02300.0FalseNoneNoneFalseNoneFalse7806.00
3600607131041NonePWD ELE SR V-6,IT.NO 8.13.1Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 Pair Each427.46427.461.0FalseNoneNoneFalseNoneFalse427.460
3600608131041NoneMARKET RATETELEPHONES Analog push button telephone with Caller ID, flash and radiaLNo1858.51858.58.0FalseNoneNoneFalseNoneFalse14868.00
3600609131041NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) Rmtr96.6496.64300.0FalseNoneNoneFalseNoneFalse28992.00
17218095170000NoneNoneBuildingsHEMALAPUR PHC(EXTERNAL ELECTRICAL& DG SET)1241018.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600610131042NoneBSR- CDS-15Supply and fixing of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles) Set31573.4431573.441.0FalseNoneNoneFalseNoneFalse31573.440
3600611131042NoneBSR- CDS-15Supply of 11 kV, 45 KN Polymeric Insulator No250.28250.286.0FalseNoneNoneFalseNoneFalse1501.680
3600612131042NoneBSR- CDS-15Supply and fixing of Guy Set Complete with No. 15 Strain Insulator & Concreting materials Set2053.022053.022.0FalseNoneNoneFalseNoneFalse4106.040
3600613131042NoneBSR- CDS-15Supply and fixing of Spiral Earth Electrode No394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3600614131042NoneBSR- CDS-15Fixing of Guy concreting with Boulders, Mud and Sand No247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3600615131042NoneBSR- CDS-15Supply and fixing of Caution/Danger Board No256.47256.471.0FalseNoneNoneFalseNoneFalse256.470
3600616131042NoneBSR- CDS-15Supply and fixing of Anti Climbing Device (12 Mtr GI Barbed Wire Each154.88154.882.0FalseNoneNoneFalseNoneFalse309.760
3600617131042NoneBSR- CDS-15Supply and fixing of 11 kV, 400 Amps Double Break GOS Set26541.8626541.861.0FalseNoneNoneFalseNoneFalse26541.860
3600618131042NoneBSR- CDS-15Supply and fixing of H-Frame for mounting GOS No5421.865421.861.0FalseNoneNoneFalseNoneFalse5421.860
3600619131042NoneBSR- CDS-15Supply and fixing of DOLO Cut Out Set of 3 Nos7248.157248.151.0FalseNoneNoneFalseNoneFalse7248.150
3600620131042NoneBSR- 13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. No203691.6203691.61.0FalseNoneNoneFalseNoneFalse203691.60
3600621131042NoneSR 19-20 6.1Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. No3716.633716.636.0FalseNoneNoneFalseNoneFalse22299.780
3600622131042NoneSR 19-20-6.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip Rmtr142.49142.4960.0FalseNoneNoneFalseNoneFalse8549.40
3600623131042NoneSR 19-20-6.3.8Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip Rmtr1771.771771.7760.0FalseNoneNoneFalseNoneFalse106306.20
3600624131042NoneSR 19-20-6.3.10Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate Each8549.18549.14.0FalseNoneNoneFalseNoneFalse34196.40
3600625131042NoneBSR-45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2) 3x95Sqmm.Outdoor Set4913.874913.873.0FalseNoneNoneFalseNoneFalse14741.610
3600626131042NoneBSR-45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP (68/8.2) 3x95Sqmm.Indoor Set4523.594523.592.0FalseNoneNoneFalseNoneFalse9047.180
3600627131042NoneBSR-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975." 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1382246.991382246.990.03FalseNoneNoneFalseNoneFalse41467.40970
3600628131042NoneBSR-38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint.Sqm1222.891222.8980.0FalseNoneNoneFalseNoneFalse97831.20
3600629131042NoneBSR-65.04Rubber Hand gloves 15 kV, SEAMLESS Confirming to ISS (Sample to be verified for seamless before approval) for electrical purpose Pair1365.381365.382.0FalseNoneNoneFalseNoneFalse2730.760
3600630131042NoneIT.NO 15.122Supplying of first aid box. Complete Each3717.03717.02.0FalseNoneNoneFalseNoneFalse7434.00
3600631131042NoneMARKET RATESupplying of FIRST AID CHART with lamination. Complete Each309.75309.752.0FalseNoneNoneFalseNoneFalse619.50
3600632131042NoneIT.NO 5.42.1LT KIOSK Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG Sq CM0.470.47110000.0FalseNoneNoneFalseNoneFalse51700.00
3600633131042NoneIT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips Rmtr3813.643813.644.0FalseNoneNoneFalseNoneFalse15254.560
3600634131042NoneIT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm Rmtr340.73340.738.0FalseNoneNoneFalseNoneFalse2725.840
3600635131042NoneIT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel Rmtr842.52842.528.0FalseNoneNoneFalseNoneFalse6740.160
3600636131042NoneIT.NO 5.14Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 125Amps 25kA Each12479.2112479.212.0FalseNoneNoneFalseNoneFalse24958.420
3600637131042NoneIT.NO 5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP Each1366.621366.624.0FalseNoneNoneFalseNoneFalse5466.480
3600638131042NoneIT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C Each574.9574.93.0FalseNoneNoneFalseNoneFalse1724.70
3600639131042None10.1.1Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class HMounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibr 15KVA/12kwSet432547.3432547.31.0FalseNoneNoneFalseNoneFalse432547.30
3600640131042None10.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility.15KVAEach72743.4672743.461.0FalseNoneNoneFalseNoneFalse72743.460
17218095170000NoneNoneBuildingsHEMALAPUR PHC(SEPTIC TANK & SOAK PIT))477864.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600641131043NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3600642131043NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3600643131043NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3600644131043NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3600645131043NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.47FalseNoneNoneFalseNoneFalse5997.43890
3600646131043NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3600647131043NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.78FalseNoneNoneFalseNoneFalse197290.25160
3600648131043NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3600649131043NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3600650131043NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3600651131043NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3600652131043NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3600653131043NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3600654131043NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3600655131043NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3600656131043NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
17218095170000NoneNoneBuildingsHEMALAPUR PHC(SUMP TANK)326860.58
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600657131044NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3600658131044NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3600659131044NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3600660131044NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3600661131044NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3600662131044NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3600663131044NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3600664131044NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3600665131044NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3600666131044NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3600667131044NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
17218095170000NoneNoneBuildingsHEMALAPUR PHC(UPS)415116.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600668131045NonePWD SR 2023-24 Volume 6 It No-9.3.5Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3600669131045NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
17218095170000NoneNoneBuildingsHEMALAPUR PHC(ACs)122781.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600670131046None6.8.2Supplyingof .TRInvertor type splitAirconditionerssuitable foroperation onA/Csupply singlephase50Hz230Vwith hermetically sealed inverter compressor with air cooled condenser, latestR410A/R-32refrigerant fanmotor,start& runcapacitors, relay&overloadprotector internal unit,with one indoor&one outdoor unit The condenser unit will be placedoutsidetheroomavoidnoiseincluding standardlength of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 3 star - 1.5 Ton capacityEach53435.1253435.122.0FalseNoneNoneFalseNoneFalse106870.240
3600671131046None6.10Installation charges for split type air conditioner with allied worksforoneindoorandoneoutdoorunit istobemountedon suitableAngle Iron support upto3.0Tonsplit/cassette type A/C.Each3746.53746.52.0FalseNoneNoneFalseNoneFalse7493.00
3600672131046None9.1.1Supplying, erecting, testing and commissioning of voltage stabilizersuitablefor170to270vinputandloadvariationfrom no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete - 3kVA CapacityEach4209.064209.062.0FalseNoneNoneFalseNoneFalse8418.120
17218095170000NoneNoneBuildingsHEMALAPUR PHC(street lighting system)318859.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600673131047NonePWD SR 2023-24 Volume 6 It No-4.4.5Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3600674131047NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3600675131047NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3600676131047NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3600677131047NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3600678131047NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3600679131047NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3600680131047NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3600681131047NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3600682131047NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3600683131047NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3600684131047NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3600685131047NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
17218095170000NoneNoneBuildingsHEMALAPUR PHC(CC Road)821594.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600686131048NonePWD SR 2023-24 V-3 Page No-9 It No-2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.923.6FalseNoneNoneFalseNoneFalse1752.9120
3600687131048NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.7108.0FalseNoneNoneFalseNoneFalse12711.60
3600688131048NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.09108.0FalseNoneNoneFalseNoneFalse14049.720
3600689131048NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.28108.0FalseNoneNoneFalseNoneFalse63426.240
3600690131048NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3600691131048NoneCSR 2023-24 Vol-3,P. No. 26,It. No. 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum3170.63170.654.0FalseNoneNoneFalseNoneFalse171212.40
3600692131048NonePWDSR2023-24 V-3 Page No-51 It No-6.6Construction of un-reinforced plain cement concrete pavementusing RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90kg/m3 (75:25 proportion) as per approved mix design procedureand thickness as per design, over a prepared sub base. Thesuperplastisiser confirming to IS 9103-1999 Reaffirmed-2008,Coarse aggregates and Fine aggregate confirming to IS:383-2016,transported to site, laid in approved fixed side form work (steelchannel, laying and fixing of 125 micron thick polythene film,wedges, steel plates including levelling the form work). Spreadingthe concrete with shovels, rackers and compacted using needle,suitable plate vibrator and finished in a continuous operation Including provision of separation membrane and Hessian clothfinishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification& direction of Engineer incharge of the workCum8392.988392.9854.0FalseNoneNoneFalseNoneFalse453220.920
17218095170000NoneNoneBuildingsHEMALAPUR PHC(Compound wall)3658914.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600693131049None1.5Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.46194.87FalseNoneNoneFalseNoneFalse72191.54020
3600694131049None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3743.06FalseNoneNoneFalseNoneFalse319521.13220
3600695131049None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenanceCum8412.768412.7624.3FalseNoneNoneFalseNoneFalse204430.0680
3600696131049None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Cum13242.3113242.3144.5FalseNoneNoneFalseNoneFalse589282.7950
3600697131049None2.11ASupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne110837.22110837.228.36FalseNoneNoneFalseNoneFalse926599.15920
3600698131049None6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum9873.599873.5974.87FalseNoneNoneFalseNoneFalse739235.68330
3600699131049None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.671144.03FalseNoneNoneFalseNoneFalse525876.27010
3600700131049None8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Set of 2 Nos193.28193.281144.03FalseNoneNoneFalseNoneFalse221118.11840
3600701131049NonePWD Volume- 2 SR 2023-24 Page No-84 It No-11.25.Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kg168.5168.5360.0FalseNoneNoneFalseNoneFalse60660.00
17218095170000NoneNoneBuildingsHEMALAPUR PHC(Borewell)419515.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600702131050NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3600703131050NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depthRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3600704131050NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3600705131050NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3600706131050NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.Rmtr2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3600707131050NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsRmtr681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3600708131050NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3600709131050NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3600710131050None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3600711131050NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" Each34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3600712131050NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3600713131050NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3600714131050NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3600715131050NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3600716131050NoneV-5P156I13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3600717131050NoneEleSrP No 12 2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)Rmtr121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3600718131050NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3600719131050NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3600720131050NoneEle SrP No 44,I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeEach361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3600721131050NoneEle rP No 47No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralEach2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3600722131050NoneEle SP No 44,INo 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeEach2230.292230.291.0FalseNoneNoneFalseNoneFalse2230.290
3600723131050NoneEleSr No 48,I No.6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Each495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
17218095170000NoneNoneBuildingsHEMALAPUR PHC(RWH)53000.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600724131051NoneV-1page5itm1.4.Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum299.84299.846.79FalseNoneNoneFalseNoneFalse2035.91360
3600725131051NoneV-1PAGE5ITM1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.96.79FalseNoneNoneFalseNoneFalse2178.9110
3600726131051NoneV-2P175I17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.Each1391.41391.428.0FalseNoneNoneFalseNoneFalse38959.20
3600727131051NoneV-2P175I17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.51241.51.13FalseNoneNoneFalseNoneFalse1402.8950
3600728131051NoneV-2P175I17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.51469.50.57FalseNoneNoneFalseNoneFalse837.6150
3600729131051NoneV-2P175I17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.91476.90.57FalseNoneNoneFalseNoneFalse841.8330
3600730131051NoneV-2P175I17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.Cum1659.01659.00.57FalseNoneNoneFalseNoneFalse945.630
3600731131051NoneV-2P177I17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1449.61449.64.0FalseNoneNoneFalseNoneFalse5798.40
17218095170000NoneNoneBuildingsHEMALAPUR PHC NURSE QTRS (Civil Works)3682939.99
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600732131052NoneV-3 P.NO 7 IT.NO 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle Sqm486.92486.92300.0FalseNoneNoneFalseNoneFalse146076.00
3600733131052NoneV-1 P.NO 8 IT.NO 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Cum117.71117.7190.0FalseNoneNoneFalseNoneFalse10593.90
3600734131052NoneV-1 p.NO 8 IT.NO 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Cum126.38126.3861.03FalseNoneNoneFalseNoneFalse7712.97140
3600735131052NoneV-1 p.no 8 IT.NO 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth Cum449.76449.7626.15FalseNoneNoneFalseNoneFalse11761.2240
3600736131052NoneV-3 P.NO 3 IT.NO ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) Cum167.27167.2756.15FalseNoneNoneFalseNoneFalse9392.21050
3600737131052NoneV-2 P.NO 5 IT.NO 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Sqm146.21146.21139.0FalseNoneNoneFalseNoneFalse20323.190
3600738131052NoneV-1 P.NO 7 IT.NO 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum329.58329.5861.03FalseNoneNoneFalseNoneFalse20114.26740
3600739131052NoneV-1 P.NO 7 IT.NO 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum587.29587.2960.8FalseNoneNoneFalseNoneFalse35707.2320
3600740131052NoneV-1 P.NO 15 IT.NO 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Cum7420.387420.3825.88FalseNoneNoneFalseNoneFalse192039.43440
3600741131052NoneV-1 P.NO 15 IT.NO 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8412.778412.7711.1FalseNoneNoneFalseNoneFalse93381.7470
3600742131052NoneV-1 P.NO 15 IT.NO 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including Form work cost, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PEDESTAL Cum8568.568568.5611.77FalseNoneNoneFalseNoneFalse100851.95120
3600743131052NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum14413.4214413.429.06FalseNoneNoneFalseNoneFalse130585.58520
3600744131052NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM Cum12717.7212717.726.15FalseNoneNoneFalseNoneFalse78213.9780
3600745131052NoneV-1 P.N 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates STAIRCASE GROUND FLOOR Cum12293.812293.82.38FalseNoneNoneFalseNoneFalse29259.2440
3600746131052NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAMS GROUND FLOOR Cum13565.5713565.575.42FalseNoneNoneFalseNoneFalse73525.38940
3600747131052NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF SLAB GROUND FLOOR Cum12717.7212717.7214.11FalseNoneNoneFalseNoneFalse179447.02920
3600748131052NoneV-1 P.NO 17 IT.NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates LINTELS GROUND FLOOR Cum13565.5713565.571.67FalseNoneNoneFalseNoneFalse22654.50190
3600749131052NoneV-1 P.NO 15 IT.NO 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including Form work cost, all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Cum11169.1611169.161.27FalseNoneNoneFalseNoneFalse14184.83320
3600750131052NoneV-3 P.NO 117 IT.NO 15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy No252.76252.764.0FalseNoneNoneFalseNoneFalse1011.040
3600751131052NoneV-2 P.NO 9 IT.NO 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum7915.987915.981.33FalseNoneNoneFalseNoneFalse10528.25340
3600752131052NoneV-1 P.NO 18 IT.NO 2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification t110837.23110837.236.15FalseNoneNoneFalseNoneFalse681648.96450
3600753131052Nonesr-18-19 P.NO14 IT.NO 4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS Rmtr38.9438.9426.22FalseNoneNoneFalseNoneFalse1021.00680
3600754131052NoneData RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. Rmtr86.1486.1426.22FalseNoneNoneFalseNoneFalse2258.59080
3600755131052NoneV-2 P.NO 14 IT.NO 6.32Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm9873.69873.640.15FalseNoneNoneFalseNoneFalse396425.040
3600756131052NoneV-2 P.NO 14 IT.NO 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1209.271209.2732.25FalseNoneNoneFalseNoneFalse38998.95750
3600757131052NoneV-2 P.NO 100 IT.NO 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum122431.79122431.790.19FalseNoneNoneFalseNoneFalse23262.04010
3600758131052NoneV-2 P.NO 105 IT.NO 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. No1258.831258.834.0FalseNoneNoneFalseNoneFalse5035.320
3600759131052NoneV-2 P.NO 107 IT.NO 12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. No1303.431303.434.0FalseNoneNoneFalseNoneFalse5213.720
3600760131052NoneV-2 P.NO 107 IT.NO 12.61Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. No1226.611226.614.0FalseNoneNoneFalseNoneFalse4906.440
3600761131052NoneV-2 P.NO 107 IT.NO 12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete" No293.65293.654.0FalseNoneNoneFalseNoneFalse1174.60
3600762131052NoneV-2 P.NO 107 IT.NO 12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete No161.07161.074.0FalseNoneNoneFalseNoneFalse644.280
3600763131052NoneV-2 P.NO 107 IT.NO 12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms No68.1568.154.0FalseNoneNoneFalseNoneFalse272.60
3600764131052NoneV-2 P.NO 108 IT.NO 12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) No340.73340.734.0FalseNoneNoneFalseNoneFalse1362.920
3600765131052NoneV-2 P.NO 69 IT.NO 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm No74.3474.3424.0FalseNoneNoneFalseNoneFalse1784.160
3600766131052NoneXI, 18-19 SR, 309 (0115)Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. Rmtr15.015.019.35FalseNoneNoneFalseNoneFalse290.250
3600767131052NoneV-2 P.NO 106 IT.NO 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Sqm4115.964115.967.88FalseNoneNoneFalseNoneFalse32433.76480
3600768131052NoneV-2 (CPWD) P.NO 542 IT.NO 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 26.87.1 30 mm thick Sqm4317.924317.923.15FalseNoneNoneFalseNoneFalse13601.4480
3600769131052NoneV-2 (CPWD) P.NO 541 IT.NO 26.86.2Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).26.86.2 Frame size 45 x 85 mm Rmtr869.78869.789.9FalseNoneNoneFalseNoneFalse8610.8220
3600770131052NoneV-2 P.NO 109 IT.NO 12.87Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm8116.698116.6911.34FalseNoneNoneFalseNoneFalse92043.26460
3600771131052NoneV-2 P.NO 109 IT.NO 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7085.857085.851.08FalseNoneNoneFalseNoneFalse7652.7180
3600772131052NoneV-2 P.NO 110 IT.NO 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg208.16208.16215.41FalseNoneNoneFalseNoneFalse44839.74560
3600773131052NoneV-2 P.NO 81 IT.NO 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FOR WATER TANK STAND Kg182.14182.14102.75FalseNoneNoneFalseNoneFalse18714.8850
3600774131052NoneV-2 P.NO 41 IT.NO 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) Sqm386.57386.57434.01FalseNoneNoneFalseNoneFalse167775.24570
3600775131052NoneV-2 P.NO 43 IT.NO 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm261.43261.4349.3FalseNoneNoneFalseNoneFalse12888.4990
3600776131052NoneV-2 P.NO 50 IT.NO 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm123.9123.9483.31FalseNoneNoneFalseNoneFalse59882.1090
3600777131052NoneV-2 P.NO 41 IT.NO 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Outside) Sqm432.42432.42218.46FalseNoneNoneFalseNoneFalse94466.47320
3600778131052NoneV-2 P.NO 42 IT.NO 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm438.61438.6114.02FalseNoneNoneFalseNoneFalse6149.31220
3600779131052NoneP.NO118,18-19 SR ,IT.NO 15.36KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) Rmtr38.7838.78301.69FalseNoneNoneFalseNoneFalse11699.53820
3600780131052NoneP.NO 70,18-19 SR,IT.NO 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. Sqm270.18270.185.0FalseNoneNoneFalseNoneFalse1350.90
3600781131052NoneV-2 P.NO 54 IT.NO 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr64.4364.43166.05FalseNoneNoneFalseNoneFalse10698.60150
3600782131052NoneV-2 P.NO 61 IT.NO 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm Sqm1455.831455.8347.9FalseNoneNoneFalseNoneFalse69734.2570
3600783131052NoneV-2 P.NO 63 IT.NO 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sqm3055.383055.3826.68FalseNoneNoneFalseNoneFalse81517.53840
3600784131052NoneV-2,P.NO 65,IT.NO 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. Sqm2044.352044.355.46FalseNoneNoneFalseNoneFalse11162.1510
3600785131052NoneV-2,P.NO 41,IT.NO 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm365.51365.5140.97FalseNoneNoneFalseNoneFalse14974.94470
3600786131052NoneV-2,P.NO 60,IT.NO 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1101.481101.487.3FalseNoneNoneFalseNoneFalse8040.8040
3600787131052NoneV-2 P.NO 65 IT.NO 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1795.321795.3240.97FalseNoneNoneFalseNoneFalse73554.26040
3600788131052NoneV-2 P.NO 83 IT.NO 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg700.04700.04337.83FalseNoneNoneFalseNoneFalse236494.51320
3600789131052NoneV-2 P.NO 48 IT.NO 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm157.36157.36483.31FalseNoneNoneFalseNoneFalse76053.66160
3600790131052NoneV-2 P.NO 45 IT.NO 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm193.29193.29196.61FalseNoneNoneFalseNoneFalse38002.74690
3600791131052NoneV-2 P.NO 45 IT.NO 8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops Sqm350.64350.6421.85FalseNoneNoneFalseNoneFalse7661.4840
3600792131052NoneV-2 P.NO 47 IT.NO 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm61.9561.956.21FalseNoneNoneFalseNoneFalse384.70950
3600793131052NoneV-2 P.NO 48 IT.NO 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm142.49142.496.21FalseNoneNoneFalseNoneFalse884.86290
3600794131052NoneV-2 P.NO 47 IT.NO 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm65.6765.6718.9FalseNoneNoneFalseNoneFalse1241.1630
3600795131052NoneV-2 P.NO 46 IT.NO 8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade.Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brandandmanufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeas per specifications and as per directions of Engineer-in-charge. Sqm170.99170.9918.9FalseNoneNoneFalseNoneFalse3231.7110
3600796131052NoneV-2 P.NO 75 IT.NO 11.5.1Providing and fixing 1mm thick M.S.steel garage door with frame and diagonal braces of size 40x40x6 mm angle Iron 3.15mm thick M.S.Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications. Sqm5548.255548.252.1FalseNoneNoneFalseNoneFalse11651.3250
3600797131052Nonedata rateProviding & laying Screed Concreete using 12mm & down size graded granite/trap metal,average thickness of 7.50cms including finishing etc complete as per specification with all lead & lift as directed by Engineer incharge.(Data Rate) - With all lead and lifts etc., complete as per specification and as per the directions of the Engineer-In-Charge of the work. Sqm585.28585.28139.0FalseNoneNoneFalseNoneFalse81353.920
3600798131052NoneV-2 P.NO 26 IT.NO 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm703.76703.768.4FalseNoneNoneFalseNoneFalse5911.5840
3600799131052NoneV-5 P.NO 34 IT.NO 3713PVC pipes of 6 Kg/cm2 for 110mm(1.894) Rmtr443.57443.5760.0FalseNoneNoneFalseNoneFalse26614.20
17218095170000NoneNoneBuildingsHEMALAPUR PHC NUSE QTRS (Internal WS AND SANITARY)276216.78
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600800131053NoneV-2 P.NO 28 IT.NO 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Rmtr113.99113.9910.0FalseNoneNoneFalseNoneFalse1139.90
3600801131053NoneV-5 P.NO 187 IT.NO T090Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines Rmtr213.38213.3810.0FalseNoneNoneFalseNoneFalse2133.80
3600802131053NoneV-5 P.NO 34 IT.NO 3711PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Rmtr337.73337.7340.0FalseNoneNoneFalseNoneFalse13509.20
3600803131053NoneV-5 P.NO 34 IT.NO 3713PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Rmtr630.94630.9435.0FalseNoneNoneFalseNoneFalse22082.90
3600804131053NoneV-2 P.NO 119 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter Rmtr244.08244.0815.0FalseNoneNoneFalseNoneFalse3661.20
3600805131053NoneV-2 P.NO 119 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter Rmtr360.55360.5510.0FalseNoneNoneFalseNoneFalse3605.50
3600806131053NoneV-5 P.NO 34 IT.NO 3711PVC pipe - OD 75mm and 6 Kg/sqcm - (Shaft Drainage) Rmtr337.01337.0120.0FalseNoneNoneFalseNoneFalse6740.20
3600807131053NoneV-5 P.NO 34 IT.NO 3713PVC pipe - OD 110mm and 6 Kg/sqcm - (Shaft Drainage) Rmtr630.94630.9420.0FalseNoneNoneFalseNoneFalse12618.80
3600808131053NoneV-2 P.NO 128 IT.NO 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. No1511.581511.582.0FalseNoneNoneFalseNoneFalse3023.160
3600809131053NoneV-2 P.NO 116 IT.NO 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter No345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3600810131053NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. No6891.326891.321.0FalseNoneNoneFalseNoneFalse6891.320
3600811131053NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. No614.54614.541.0FalseNoneNoneFalseNoneFalse614.540
3600812131053NoneV-2 P.NO 123 IT.NO 14.3Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required No7192.47192.41.0FalseNoneNoneFalseNoneFalse7192.40
3600813131053NoneV-2 P.NO 126 IT.NO14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm No5986.855986.852.0FalseNoneNoneFalseNoneFalse11973.70
3600814131053NoneV-2 P.NO A-14 IT.NO 91C.P. Brass stop cock (concealed) 15 mm No650.48650.482.0FalseNoneNoneFalseNoneFalse1300.960
3600815131053NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps No3818.63818.61.0FalseNoneNoneFalseNoneFalse3818.60
3600816131053NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia Rmtr382.85382.8520.0FalseNoneNoneFalseNoneFalse7657.00
3600817131053NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." GROUND FLOOR 20 mm dia Rmtr469.58469.5820.0FalseNoneNoneFalseNoneFalse9391.60
3600818131053NoneV-2 P.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." GROUND FLOOR 25 mm dia Rmtr591.0591.025.0FalseNoneNoneFalseNoneFalse14775.00
3600819131053NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm dia Rmtr690.12690.1210.0FalseNoneNoneFalseNoneFalse6901.20
3600820131053NoneV-2 P.NO 120 IT.NO 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)" External & Shafts & Terrace 40mm DWS Rmtr591.0591.045.0FalseNoneNoneFalseNoneFalse26595.00
3600821131053NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)" External & Shafts & Terrace 50mm DWS Rmtr893.32893.3215.0FalseNoneNoneFalseNoneFalse13399.80
3600822131053NoneV-2,A-13,IT.NO 66Brass bib-cock 15 mm dia No354.35354.354.0FalseNoneNoneFalseNoneFalse1417.40
3600823131053NoneV-2 IT.NO 13.34KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. (For 1000 litre capacity) Specification No.KBS 13.22No11.1511.151000.0FalseNoneNoneFalseNoneFalse11150.00
3600824131053NoneMarket RateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards Ground Toilet 10Cms X 7.5Cms No371.7371.710.0FalseNoneNoneFalseNoneFalse3717.00
3600825131053NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) No177.0177.010.0FalseNoneNoneFalseNoneFalse1770.00
3600826131053NoneMarket RateDrilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 7.50 cms thick No154.58154.585.0FalseNoneNoneFalseNoneFalse772.90
3600827131053NoneMarket RateDrilling holes of 2.50 cms dia (roof/chajja/stone). -do- in slabs upto 10 cms thick No185.26185.265.0FalseNoneNoneFalseNoneFalse926.30
3600828131053NoneMarket RateAir Vent Cowel 75mm No413.0413.010.0FalseNoneNoneFalseNoneFalse4130.00
3600829131053NoneMarket RateAir Vent Cowel 110mm No590.0590.010.0FalseNoneNoneFalseNoneFalse5900.00
3600830131053NoneMarket RateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards No5664.05664.02.0FalseNoneNoneFalseNoneFalse11328.00
3600831131053NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). No2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3600832131053NoneMarket RateSupplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON-CHR-347KN for pantry sink with CP wall flange etc. Standard make confiMing to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) No1996.561996.562.0FalseNoneNoneFalseNoneFalse3993.120
3600833131053NoneMarket RateProviding and fixing CI Nahani trap of approved make confirming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot. Each295.0295.05.0FalseNoneNoneFalseNoneFalse1475.00
3600834131053NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. c) 50mm diaNo3304.03304.02.0FalseNoneNoneFalseNoneFalse6608.00
3600835131053NoneCPWD SR, V-2,377,1927Brass full way valve with C.I. wheel (screwed end) 25 mm diaEach442.5442.53.0FalseNoneNoneFalseNoneFalse1327.50
3600836131053NoneCPWD SR, V-2,377,1928Brass full way valve with C.I. wheel (screwed end) 32 mm diaEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3600837131053NoneCPWD SR, V-2,377,1929Brass full way valve with C.I. wheel (screwed end) 40 mm diaEach590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3600838131053None8.3.1Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.Each37498.037498.01.0FalseNoneNoneFalseNoneFalse37498.00
17218095180000NoneNoneBuildingsHEMALAPUR PHC NURSE QTRS(INERNAL ELECTRICAL)150783.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600839131054NoneIT.NO 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box Point333.29333.296.0FalseNoneNoneFalseNoneFalse1999.740
3600840131054NoneIT.NO 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box Point469.58469.587.0FalseNoneNoneFalseNoneFalse3287.060
3600841131054NoneIT.NO 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box Point687.65687.657.0FalseNoneNoneFalseNoneFalse4813.550
3600842131054NoneIT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way Each170.98170.989.0FalseNoneNoneFalseNoneFalse1538.820
3600843131054NoneIT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Each197.0197.01.0FalseNoneNoneFalseNoneFalse197.00
3600844131054NoneIT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Each219.3219.31.0FalseNoneNoneFalseNoneFalse219.30
3600845131054NoneIT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Each272.58272.583.0FalseNoneNoneFalseNoneFalse817.740
3600846131054NoneIT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Each323.38323.382.0FalseNoneNoneFalseNoneFalse646.760
3600847131054NoneIT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module Each216.83216.831.0FalseNoneNoneFalseNoneFalse216.830
3600848131054NoneIT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Moudule Each216.83216.831.0FalseNoneNoneFalseNoneFalse216.830
3600849131054NoneIT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6Moudule Each289.93289.931.0FalseNoneNoneFalseNoneFalse289.930
3600850131054NoneIT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Moudule Each351.88351.883.0FalseNoneNoneFalseNoneFalse1055.640
3600851131054NoneIT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10Moudule Each426.22426.222.0FalseNoneNoneFalseNoneFalse852.440
3600852131054NoneIT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. Each126.38126.3828.0FalseNoneNoneFalseNoneFalse3538.640
3600853131054NoneIT.NO 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way. Each205.67205.674.0FalseNoneNoneFalseNoneFalse822.680
3600854131054NoneIT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. Each211.87211.8710.0FalseNoneNoneFalseNoneFalse2118.70
3600855131054NoneIT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Each442.32442.323.0FalseNoneNoneFalseNoneFalse1326.960
3600856131054NoneIT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch Each403.91403.913.0FalseNoneNoneFalseNoneFalse1211.730
3600857131054NoneIT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket Each292.4292.43.0FalseNoneNoneFalseNoneFalse877.20
3600858131054NoneIT.NO 3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3600859131054NoneIT.NO 13.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3600860131054NoneIT.NO 1.12Supplyin and Fixing Metal Fan Box with Round Hook. No144.96144.963.0FalseNoneNoneFalseNoneFalse434.880
3600861131054NoneITM 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick Rmtr81.7781.77160.0FalseNoneNoneFalseNoneFalse13083.20
3600862131054NoneITM 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick Rmtr96.6496.6470.0FalseNoneNoneFalseNoneFalse6764.80
3600863131054NoneITM 1.2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick Rmtr127.66127.6620.0FalseNoneNoneFalseNoneFalse2553.20
3600864131054NoneITM 1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 19/20mm dia 2mm thick Rmtr84.2584.2575.0FalseNoneNoneFalseNoneFalse6318.750
3600865131054NoneITM 1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 25mm dia 2mm thick Rmtr97.8897.8840.0FalseNoneNoneFalseNoneFalse3915.20
3600866131054NoneITM 1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.(2/1.3) 32mm dia 2.5mm thick Rmtr122.66122.6610.0FalseNoneNoneFalseNoneFalse1226.60
3600867131054NoneITM 2.5.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5) 1.5 sqmm Rmtr32.2132.2175.0FalseNoneNoneFalseNoneFalse2415.750
3600868131054NoneITM 2.5.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5) 2.5 sqmm Rmtr52.0452.04180.0FalseNoneNoneFalseNoneFalse9367.20
3600869131054NoneITM 2.5.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:1990 & comfirming to GTP of Group-A .(6/2.5) 4 sqmm Rmtr78.0678.0660.0FalseNoneNoneFalseNoneFalse4683.60
3600870131054NoneBSR-32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm Km125279.01125279.010.1FalseNoneNoneFalseNoneFalse12527.9010
3600871131054NoneBSR-31Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm Km20021.020021.00.1FalseNoneNoneFalseNoneFalse2002.10
3600872131054NoneSR 19-20 ITM 6.11Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm Each84.2584.254.0FalseNoneNoneFalseNoneFalse337.00
3600873131054NoneSR 19-20 ITM 6.6.2Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (hard) Rmtr126.38126.3860.0FalseNoneNoneFalseNoneFalse7582.80
3600874131054NoneITM 8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair Rmtr26.0226.0220.0FalseNoneNoneFalseNoneFalse520.40
3600875131054NoneITM8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. MCB DB Rmtr54.5254.5225.0FalseNoneNoneFalseNoneFalse1363.00
3600876131054NoneITM5.18.8Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure Double Door 12 Way SP & NEach3771.523771.521.0FalseNoneNoneFalseNoneFalse3771.520
3600877131054NoneITM5.17.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP Each514.19514.1910.0FalseNoneNoneFalseNoneFalse5141.90
3600878131054NoneITM 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole Each6538.26538.21.0FalseNoneNoneFalseNoneFalse6538.20
3600879131054NoneITM 11.3Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w Each854.91854.916.0FalseNoneNoneFalseNoneFalse5129.460
3600880131054NoneITM 12.46Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Supplying & Fixing of 70-150 Watts lamp holder 2 Pin Each183.37183.378.0FalseNoneNoneFalseNoneFalse1466.960
3600881131054NoneITM11.11.3Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K Each184.61184.613.0FalseNoneNoneFalseNoneFalse553.830
3600882131054Noneitm11.11.5Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500KEach333.29333.291.0FalseNoneNoneFalseNoneFalse333.290
3600883131054NoneItm 11.11.7Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18W, 6500KEach527.81527.812.0FalseNoneNoneFalseNoneFalse1055.620
3600884131054None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power SupplyNo64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3600885131054None6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1849.01849.02.0FalseNoneNoneFalseNoneFalse3698.00
3600886131054None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.Each3697.183697.183.0FalseNoneNoneFalseNoneFalse11091.540
3600887131054None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each151.15151.156.0FalseNoneNoneFalseNoneFalse906.90
3600888131054None13.10Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each211.86211.863.0FalseNoneNoneFalseNoneFalse635.580
3600889131054None13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each875.97875.972.0FalseNoneNoneFalseNoneFalse1751.940
3600890131054None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70 maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, eEach1810.181810.181.0FalseNoneNoneFalseNoneFalse1810.180
3600891131054None13.4.1Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Single bracket 1.5 Mtr. Length Each1810.181810.181.0FalseNoneNoneFalseNoneFalse1810.180
3600892131054None13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each200.71200.711.0FalseNoneNoneFalseNoneFalse200.710
3600893131054None5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP Each915.62915.621.0FalseNoneNoneFalseNoneFalse915.620
3600894131054None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps Each298.59298.591.0FalseNoneNoneFalseNoneFalse298.590
3600895131054None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
17218095180000NoneNoneBuildingsBarur PHC (Consultancy For Architectural, Structural Design Charges)347942.74
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600896131055NoneDATA RATEThe Tenderer (agency) should arrange to obtain (get), detailed Architecturaldrawings and elevations, Structural designs and drawings including Soil exploration & proofchecking by IISC /IIT/NIT/any Engineering college only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge LS347942.74347942.741.0FalseNoneNoneFalseNoneFalse347942.740
17218095180000NoneNoneBuildingsHEMALAPUR PHC(Consultancy For Architectural, Structural Design Charges)347942.74
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3600897131056NoneDATA RATEThe Tenderer (agency) should arrange to obtain (get), detailed Architecturaldrawings and elevations, Structural designs and drawings including Soil exploration & proofchecking by IISC /IIT/NIT/any Engineering college only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge LS347942.74347942.741.0FalseNoneNoneFalseNoneFalse347942.740
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218095180000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218095180000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218095180000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17218095180000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218095180000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218095270000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17218095330000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17218095380000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17218095430000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17218095480000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17218095540000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17218095600000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17218095650000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17218095700000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17218095750000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17218095800000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17218095840000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17218095890000NoneNoneELIGIBILITYMaterials like, steel(primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17218095950000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17218096040000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17218096090000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17218096130000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17218096170000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17218096240000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17218096310000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.1424.40 LakhPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.356.10 lakh as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works 1. Earthwork Excavation in all kinds of soil 3065.00 Cum 2.PCC & RCC 1175.00 Cum 3. Steel Reinforcement for RCC work (TMT Steel) 77.57 Tonne 4.BBM/Concrete Blocks 644.00 Cum. 5. Plastering 8835.00 Sqm 6. Painting (OBD/Textured Painting/Wood and Metal Painting) 7338.00 Sqm 7. Flooring (Vitrified/Granite/Ceramic) 2484.00 Sqm 8. MS Grill 3454.00 Kgs Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d The tenderer or his identified sub contractor should possess required valid electrical license issued by KPWD,Government electrical Inspectorate for executing building electrification works and should have executed similar Building electrical works totaling to Rs.26.30 Lakh in any one year Note.The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government,Semi Government,Government undertaking,autonomous bodies of Government will be considered, for the clause 3.2d.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e):The Tenderer or his identified sub-contractor should possess valid license issued by BWSSB/KUWS&DB for executing water supply/sanitary engineering works and should have executed similar building water supply/sanitary engineering works totaling to Rs.26.25 Lakh in any one year Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass - I PWD Registered Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.3(a) Equipment capacity: Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50%can be deployed on ease/hire basis for all works provided,the relevant documents (commitment agreements etc) for availability for this work are furnished SlNo. Description of Key items of Works. Quantity1. Excavator/JCB 1No 2. Transit Mixer/Concrete Mixer 1 No 3. Needle vibrator with size not less than 20mm 1 No 4.Tipper 1 No 5.Generator 250 KVA 1 No 6. Truck Mounted Water Tanker 1 No Note: All Machineries purchased during last five years only should be used and will be considered for evaluation.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneClause ITT 3.6 Tenderers who meet the above specified minimum qualifying criteria,will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2019-20-2023-24)(updated to 2024-25 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2024-25 price level, of existing commitments of and ongoing works to be Completed during the next 11 months.Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1) Site Engineer (Civil) B.E. Civil with minimum experience of 7 years in the Construction of buildings 1 (One) 2) Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.285.00 Lakh (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
ESI & PF CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721809970000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone