createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721461282192
version10
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd900000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-08-2024 17:00:00
tenderQueryClose26-07-2024 15:00:00
technicalBidOpen07-08-2024 11:40:00
publishedDate24-07-2024 14:01:23
publishedByPostKKRTC_EE_HOFF_BLR
publishedByUserKPE10109 - M ERESH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate29-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEresh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber8392294828
mobileNumber9972039797
tenderSupplierListNone
tenderSchedule
createdTs1721461282229
version19
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/BD/WORK_INDENT55
titleConstruction of New Bus Station at Talkal (Near Engineering Collage & Skill Development Centre) (Kukanur Taluk)
descriptionConstruction of New Bus Station at Talkal (Near Engineering Collage & Skill Development Centre) (Kukanur Taluk)
categoryWORKS
categoryTextWorks
ecv59999999.98
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5937
locationNameKKRTC Divisional Controller Office Bellari
provisionalAmount60000000.0
groupOverheadTotal506673.42
fileNumber00027
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17214612820001NoneNoneBuildingsConstruction of New Bus Station at Talkal (Near Engineering Collage & Skill Development Centre) (Kukanur Taluk)59493326.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3561960129078Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) Depth exceeding 1.5 m, but not exceeding 3 m.In all kinds of soils Depth upto 3 mCum126.37126.371900.83FalseNoneNoneFalseNoneFalse240207.88710
3561961129078Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum7017.697017.69318.17FalseNoneNoneFalseNoneFalse2232818.42730
3561962129078Nonecode03KSRB 2.3 : Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP- Vol-I (7/1.10)Cum520.38520.382944.87FalseNoneNoneFalseNoneFalse1532451.45060
3561963129078Nonecode04Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum7934.557934.5524.11FalseNoneNoneFalseNoneFalse191302.00050
3561964129078Nonecode05Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.3) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SRP 115/1 (Foundation upto plinth (a) Isolated)Cum8478.328478.32204.28FalseNoneNoneFalseNoneFalse1731951.20960
3561965129078Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.2) M25Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum14413.4114413.4185.8FalseNoneNoneFalseNoneFalse1236670.5780
3561966129078Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.2) M25Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.72509.44FalseNoneNoneFalseNoneFalse6478915.27680
3561967129078Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.2) M25Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12293.7912293.791.27FalseNoneNoneFalseNoneFalse15613.11330
3561968129078Nonecode09Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (106/12.57.5) 35 mm thick one side teak and one side commercialSqm4828.384828.3815.44FalseNoneNoneFalseNoneFalse74550.18720
3561969129078Nonecode10Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12)Cum153886.27153886.270.44FalseNoneNoneFalseNoneFalse67709.95880
3561970129078Nonecode11Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (105/12.54)Rmtr394.0394.017.1FalseNoneNoneFalseNoneFalse6737.40
3561971129078Nonecode12Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.SRP- Vol-II (106/12.55.2) with one side prelam.Sqm2527.562527.564.73FalseNoneNoneFalseNoneFalse11955.35880
3561972129078Nonecode13Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/11.34A)Kg208.15208.151397.65FalseNoneNoneFalseNoneFalse290920.84750
3561973129078Nonecode14Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8)Cum9873.599873.59484.95FalseNoneNoneFalseNoneFalse4788197.47050
3561974129078Nonecode15Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2)Sqm345.68345.684739.66FalseNoneNoneFalseNoneFalse1638405.66880
3561975129078Nonecode16Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.2)Sqm298.59298.593126.35FalseNoneNoneFalseNoneFalse933496.84650
3561976129078Nonecode17Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.35.1.2/86)Kg605.87605.87178.32FalseNoneNoneFalseNoneFalse108038.73840
3561977129078Nonecode18Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.37.2/82)Sqm1450.861450.8631.23FalseNoneNoneFalseNoneFalse45310.35780
3561978129078Nonecode19Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (83/11.28)Kg700.03700.03435.75FalseNoneNoneFalseNoneFalse305038.07250
3561979129078Nonecode20Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials,labour complete as per specifications and as per directions of Engineerin-charge.SRP- Vol-II (44/8.21)Sqm32.2132.214000.0FalseNoneNoneFalseNoneFalse128840.00
3561980129078Nonecode21Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30)Sqm6601.396601.39193.47FalseNoneNoneFalseNoneFalse1277170.92330
3561981129078Nonecode22Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately). SRP- Vol-II (62/9.22.2)Size of Tile 600x600 mmSqm1642.911642.9146.12FalseNoneNoneFalseNoneFalse75771.00920
3561982129078Nonecode23Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.SRP- Vol-II (64/9.34)Sqm1914.251914.25788.59FalseNoneNoneFalseNoneFalse1509558.40750
3561983129078Nonecode24Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar,labour, curing etc., complete. SRP- Vol-II (72/10.18)Sqm4161.84161.821.48FalseNoneNoneFalseNoneFalse89395.4640
3561984129078Nonecode25Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (69/10.2)Rmtr406.39406.3949.5FalseNoneNoneFalseNoneFalse20116.3050
3561985129078Nonecode26Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-I (18/2.11/a)Kg110.82110.8296116.35FalseNoneNoneFalseNoneFalse10651613.9070
3561986129078Nonecode27Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (75/11.1)Kg131.33131.334512.08FalseNoneNoneFalseNoneFalse592571.46640
3561987129078Nonecode28Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. SRP- Vol-II (26/7.38)Sqm703.75703.75308.66FalseNoneNoneFalseNoneFalse217219.4750
3561988129078Nonecode29Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete SRP- Vol-II (71/10.15.1)Sqm4942.374942.3780.33FalseNoneNoneFalseNoneFalse397020.58210
3561989129078Nonecode30Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ eams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval fromstructural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts,washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glasspanel inside the SS channel shall be measured.SRP- Vol-II (160/18.7)Sqm9852.529852.5238.91FalseNoneNoneFalseNoneFalse383361.55320
3561990129078Nonecode31KSRB 7.15 :Providing , fabricating, assembling and fixing in position anodized aluminum partions using aluminium section of mat finish or glassy finish in combination of plain grove, single groove, single grove and double grove as per requirements for the frames of overall size 63.5mmx38.1mm. with thickness of 2 mm having section weight, plain sections. 1.054 kg/m, single grove thickness 1.95mm section weight. 1.094kg/m and bottom member 114.3mm x 44.45mm thickness 3.18mm weight 2.646 kg/m aluminium louvers section of size 36.5mmx34.93mm 1.45mm thick section weight 0.429kg/m bottom prortion provided with 12mm thick prelaminated sheet both sides of approved portion viz., 0.9m to 2.13m and top panel with louvers sections; the glass and panels fitted wtih glazing clips of 19mm x 17.3mm of thickness 0.9mm weight 0.13 and top panel with louvers sections; the glass and panels fitted with glazing clips of 19mmx 17.3mm of thickness 0.9mm weight 0.124kg/m aluminium setions anodised 12 to 15 microns, sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non adherence of mortars or any other sticky materials ; vertical members embedded in the flooring by making suitable sized holes and fixing with cement mortar, with necesary opening for fixing of door of standard size ( excluding cost of door ) all the frame throughly cleaned, free from rust , scale of dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specification SRP 38/7.15.2 ( Powder Coated )Sqm4049.764049.766.48FalseNoneNoneFalseNoneFalse26242.44480
3561991129078Nonecode32Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 16.9/191Each5936.045936.047.0FalseNoneNoneFalseNoneFalse41552.280
3561992129078Nonecode33Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. SRP- Vol-V 94/9.1.4Rmtr581.09581.09180.0FalseNoneNoneFalseNoneFalse104596.20
3561993129078Nonecode34Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 187/16.1.2Rmtr719.85719.8590.0FalseNoneNoneFalseNoneFalse64786.50
3561994129078Nonecode35Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (48/8.40)Sqm142.48142.48100.0FalseNoneNoneFalseNoneFalse14248.00
3561995129078Nonecode36Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (45/8.25)Sqm169.74169.744000.0FalseNoneNoneFalseNoneFalse678960.00
3561996129078Nonecode37Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28)Sqm110.27110.272010.8FalseNoneNoneFalseNoneFalse221730.9160
3561997129078Nonecode38Providing and placing on terrace ( at all floor levels ) polyethylene water storage tanks,IS : 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP- Vol-II (12/13.34)Ltr9.919.914000.0FalseNoneNoneFalseNoneFalse39640.00
3561998129078Nonecode39Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.5) 40 mmMtr591.0591.0185.0FalseNoneNoneFalseNoneFalse109335.00
3561999129078Nonecode40Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.3) 25 mmMtr366.74366.74140.0FalseNoneNoneFalseNoneFalse51343.60
3562000129078Nonecode41Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.2) 20 mmMtr268.86268.8695.0FalseNoneNoneFalseNoneFalse25541.70
3562001129078Nonecode42Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work SRP- Vol-II (123/13.33.1) 15 mmMtr205.67205.6778.0FalseNoneNoneFalseNoneFalse16042.260
3562002129078Nonecode43White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (133/14.7.7)Nos2600.662600.664.0FalseNoneNoneFalseNoneFalse10402.640
3562003129078Nonecode44White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. SRP- Vol-II (126/14.13.2)Nos2888.12888.11.0FalseNoneNoneFalseNoneFalse2888.10
3562004129078Nonecode45Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : SRP- Vol-II (128/14.32.3)Unit1320.771320.773.0FalseNoneNoneFalseNoneFalse3962.310
3562005129078Nonecode46Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1:2:4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2Each336.3336.311.0FalseNoneNoneFalseNoneFalse3699.30
3562006129078Nonecode47Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP- Vol-II (117/13.5.1)Nos366.74366.747.0FalseNoneNoneFalseNoneFalse2567.180
3562007129078Nonecode48Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3)Nos869.77869.774.0FalseNoneNoneFalseNoneFalse3479.080
3562008129078Nonecode49Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP- Vol-II (117/13.3.1)Nos370.46370.4616.0FalseNoneNoneFalseNoneFalse5927.360
3562009129078Nonecode50Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (76/11.6.3)Sqm2818.722818.7272.96FalseNoneNoneFalseNoneFalse205653.81120
3562010129078Nonecode51Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11)Sqm1101.471101.4725.72FalseNoneNoneFalseNoneFalse28329.80840
3562011129078Nonecode52Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38)Sqm1724.681724.6885.14FalseNoneNoneFalseNoneFalse146839.25520
3562012129078Nonecode53Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.SRP- Vol-II (65/9.40)Sqm1403.781403.78133.22FalseNoneNoneFalseNoneFalse187011.57160
3562013129078Nonecode54Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.SRP- Vol-II (63/9.25)Sqm991.2991.2405.95FalseNoneNoneFalseNoneFalse402377.640
3562014129078Nonecode55Supplying and fixing MS Chairs & 3 seater of approved qulaity including fixing in flooring drilling to the suitable holes grouting complete as per direction of Engineer in charge of work complete as per specifications with all lead and lift. (Approved rate)Nos6490.06490.018.0FalseNoneNoneFalseNoneFalse116820.00
3562015129078Nonecode56Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SRP- Vol-I (7/1.8)Cum587.28587.283780.0FalseNoneNoneFalseNoneFalse2219918.40
3562016129078Nonecode57Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. SRP- Vol-III (24/4.27)Cum3170.63170.6350.0FalseNoneNoneFalseNoneFalse1109710.00
3562017129078Nonecode58Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.SRP- Vol-III (43/6.1)complete in C.C. 1:6:12 prop )Cum6095.886095.88336.0FalseNoneNoneFalseNoneFalse2048215.680
3562018129078Nonecode59Construction of M40 grade un-reinforced,Cement Concrete Pavement with OPC/PPC/PSC dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing SRP- Vol-III (43/6.2)Cum11226.5711226.57560.0FalseNoneNoneFalseNoneFalse6286879.20
3562019129078Nonecode60Supplying, fitting and placing un-coated Mild steel reinforcement complete in foundation as per drawing and technical specification. SRP- Vol-I (18/2.12)Kg91.3391.3321000.0FalseNoneNoneFalseNoneFalse1917930.00
3562020129078Nonecode61Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. SRP- Vol-V 94/9.1.4Rmtr581.09581.09150.0FalseNoneNoneFalseNoneFalse87163.50
3562021129078Nonecode62Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.7)Rmtr509.22509.22105.0FalseNoneNoneFalseNoneFalse53468.10
3562022129078Nonecode63Providing & supplying of plants from forest department of plants size 14" x 20" with supporting guard stick including transportation loading unloading placeing the plants in pits of 1 Mtr x 1 Mtr x 1 Mtr of size pits and refiling of required quantity and watering etc., complete.Each118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3562023129078Nonecode64Korean Truff (Bijapur BS Approved Rate)Sqm206.5206.550.0FalseNoneNoneFalseNoneFalse10325.00
3562024129078Nonecode65Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7669.89FalseNoneNoneFalseNoneFalse587967.79640
3562025129078Nonecode66Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13964.7613964.7619.56FalseNoneNoneFalseNoneFalse273150.70560
3562026129078Nonecode67Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12321.8512321.8538.67FalseNoneNoneFalseNoneFalse476485.93950
3562027129078Nonecode68Providing patti allround compound wall etc, with CM 1:3 and finished as per design and specification including scafolding etc, complete. Patti 10cm wide and 10 mm thick.Rmtr14.0114.01506.0FalseNoneNoneFalseNoneFalse7089.060
3562028129078Nonecode69Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12048.6612048.662.76FalseNoneNoneFalseNoneFalse33254.30160
3562029129078Nonecode70Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13565.5613565.565.42FalseNoneNoneFalseNoneFalse73525.33520
3562030129078Nonecode71Providing and placing on terrace ( at all floor levels ) polyethylene water storage tanks,IS : 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP- Vol-II (12/13.34)Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
3562031129078Nonecode72Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. SRP- Vol-II (123/14.3.2) W.C. pan with ISI marked black solid plastic seat and lid.Each7192.397192.391.0FalseNoneNoneFalseNoneFalse7192.390
3562032129078Nonecode73Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required SRP- Vol-II (131/14.1.1)Nos6051.276051.272.0FalseNoneNoneFalseNoneFalse12102.540
3562033129078Nonecode74Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and makinggood the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern SRP- Vol-II (131/14.4.1)Each5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3562034129078Nonecode75Providing and fixing white vitreous china water closet squatting pan (Indian type) Long pattern W.C. pan of size 580 mm SRP- Vol-II (134/14.13.1)Each1769.291769.292.0FalseNoneNoneFalseNoneFalse3538.580
3562035129078Nonecode76Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.SRP- Vol-II (65/9.40)Sqm1154.741154.7415.5FalseNoneNoneFalseNoneFalse17898.470
3562036129078Nonecode77Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground SRP- Vol-I (A-45/50)Hour1672.651672.6526.0FalseNoneNoneFalseNoneFalse43488.90
3562037129078Nonecode78Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13143.3113143.3114.06FalseNoneNoneFalseNoneFalse184794.93860
3562038129078Nonecode79Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1)Sqm365.5365.5103.68FalseNoneNoneFalseNoneFalse37895.040
3562039129078Nonecode80Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 0 to 50 m SRP- Vol-V (139/12.2.1)Rmtr382.85382.8560.0FalseNoneNoneFalseNoneFalse22971.00
3562040129078Nonecode81Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 50 to 100 m SRP- Vol-V (139/12.2.2)Rmtr479.49479.4930.0FalseNoneNoneFalseNoneFalse14384.70
3562041129078Nonecode82Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 100 to 150 m SRP- Vol-V (139/12.2.3)Rmtr510.46510.4660.0FalseNoneNoneFalseNoneFalse30627.60
3562042129078Nonecode83Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.9)Rmtr742.16742.1620.0FalseNoneNoneFalseNoneFalse14843.20
3562043129078Nonecode84Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 113/10.1.8)Rmtr723.57723.5740.0FalseNoneNoneFalseNoneFalse28942.80
3562044129078Nonecode85Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. 5 O050A Cleaning of borewells including yield.VOL-V 139/12.2Each6239.846239.841.0FalseNoneNoneFalseNoneFalse6239.840
3562045129078Nonecode86SRP:1.2 Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick 1.2.2Mtr96.6496.64400.0FalseNoneNoneFalseNoneFalse38656.00
3562046129078Nonecode87SRP: 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr97.8897.88150.0FalseNoneNoneFalseNoneFalse14682.00
3562047129078Nonecode881.1.2 Open Conduit System:Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr100.35100.3520.0FalseNoneNoneFalseNoneFalse2007.00
3562048129078Nonecode89SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm 2.3.2Mtr32.2132.211800.0FalseNoneNoneFalseNoneFalse57978.00
3562049129078Nonecode90SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm (P6/2.3.3)Mtr52.0352.031400.0FalseNoneNoneFalseNoneFalse72842.00
3562050129078Nonecode91SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4sqmm (P6/2.3.4)Mtr78.0578.05300.0FalseNoneNoneFalseNoneFalse23415.00
3562051129078Nonecode92SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6sqmm (P6/2.3.5)Mtr113.98113.9840.0FalseNoneNoneFalseNoneFalse4559.20
3562052129078Nonecode93SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10sqmm (P6/2.3.6)Mtr206.91206.9160.0FalseNoneNoneFalseNoneFalse12414.60
3562053129078Nonecode94SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16sqmm(P6/2.3.7)Mtr394.0394.060.0FalseNoneNoneFalseNoneFalse23640.00
3562054129078Nonecode95SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNo333.29333.2920.0FalseNoneNoneFalseNoneFalse6665.80
3562055129078Nonecode96SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2)No469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3562056129078Nonecode97SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3)No687.64687.6440.0FalseNoneNoneFalseNoneFalse27505.60
3562057129078Nonecode98Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-2Way 3.4.1No170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3562058129078Nonecode99Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4way (P15/3.4.3)No219.3219.34.0FalseNoneNoneFalseNoneFalse877.20
3562059129078Nonecode100Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 way (P15/3.4.4)No272.58272.588.0FalseNoneNoneFalseNoneFalse2180.640
3562060129078Nonecode101Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 way (P15/3.4.6)No395.24395.2412.0FalseNoneNoneFalseNoneFalse4742.880
3562061129078Nonecode102Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 18 way (P15/3.4.8)No501.79501.792.0FalseNoneNoneFalseNoneFalse1003.580
3562062129078Nonecode103Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module 3.5.1No169.74169.7425.0FalseNoneNoneFalseNoneFalse4243.50
3562063129078Nonecode104Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4mod (P16/3.5.3)No216.82216.824.0FalseNoneNoneFalseNoneFalse867.280
3562064129078Nonecode105Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module (P16/3.5.4)No289.92289.928.0FalseNoneNoneFalseNoneFalse2319.360
3562065129078Nonecode106Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (P16/3.5.6)No426.21426.2112.0FalseNoneNoneFalseNoneFalse5114.520
3562066129078Nonecode107Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18 Module (P16/3.5.8)No566.22566.222.0FalseNoneNoneFalseNoneFalse1132.440
3562067129078Nonecode108Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1No126.37126.37200.0FalseNoneNoneFalseNoneFalse25274.00
3562068129078Nonecode109Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3 way socket (P16/3.6.3)No211.86211.86120.0FalseNoneNoneFalseNoneFalse25423.20
3562069129078Nonecode110Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. modular stepped fan regulator (P16/3.6.4)No442.32442.3225.0FalseNoneNoneFalseNoneFalse11058.00
3562070129078Nonecode111Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch (P16/3.6.7)No223.02223.024.0FalseNoneNoneFalseNoneFalse892.080
3562071129078Nonecode112Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal socket (P16/3.6.10)No292.4292.44.0FalseNoneNoneFalseNoneFalse1169.60
3562072129078Nonecode113Supplying and fixing Fan box with round hook (P3/1.13)No144.96144.9625.0FalseNoneNoneFalseNoneFalse3624.00
3562073129078Nonecode114Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2Mtr27.2527.2520.0FalseNoneNoneFalseNoneFalse545.00
3562074129078Nonecode115Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fighting 1 x4'- 20/22 w 11.3.2No854.91854.9140.0FalseNoneNoneFalseNoneFalse34196.40
3562075129078Nonecode11611.5.3 Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WNo1640.431640.4312.0FalseNoneNoneFalseNoneFalse19685.160
3562076129078Nonecode117Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. Efficacy Greater than100 lumen per watt, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should Less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' / 1' x 4' 34 -36watt 11.6.3No5641.165641.164.0FalseNoneNoneFalseNoneFalse22564.640
3562077129078Nonecode11811.8.4 Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK08. Power Factor Greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater than130lm/w, nominal CRI Greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo10977.5410977.546.0FalseNoneNoneFalseNoneFalse65865.240
3562078129078Nonecode1196.3.1. Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.No3697.173697.1725.0FalseNoneNoneFalseNoneFalse92429.250
3562079129078Nonecode1206.4.1 Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value equal to 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.No3316.83316.86.0FalseNoneNoneFalseNoneFalse19900.80
3562080129078Nonecode121Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm) 7.2.1 6.2.1No3678.593678.594.0FalseNoneNoneFalseNoneFalse14714.360
3562081129078Nonecode122Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders 13.7.1No151.15151.1540.0FalseNoneNoneFalseNoneFalse6046.00
3562082129078Nonecode123Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe 13.2.3No1831.241831.246.0FalseNoneNoneFalseNoneFalse10987.440
3562083129078Nonecode124Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 6.5.1No3087.583087.582.0FalseNoneNoneFalseNoneFalse6175.160
3562084129078Nonecode125Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.13.10No211.86211.8625.0FalseNoneNoneFalseNoneFalse5296.50
3562085129078Nonecode126Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.13.13No875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3562086129078Nonecode127Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SPNo514.18514.1825.0FalseNoneNoneFalseNoneFalse12854.50
3562087129078Nonecode128Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP. (5.18.4)No915.62915.6230.0FalseNoneNoneFalseNoneFalse27468.60
3562088129078Nonecode129Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps TPN. (5.18.7)No2127.362127.364.0FalseNoneNoneFalseNoneFalse8509.440
3562089129078Nonecode130Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN . (5.18.9)No3826.033826.034.0FalseNoneNoneFalseNoneFalse15304.120
3562090129078Nonecode131Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than80 lumen per watt, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater than 0.95, power loss should Less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.11.2.1:Each771.89771.898.0FalseNoneNoneFalseNoneFalse6175.120
3562091129078Nonecode132Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. 12.2.3Each1474.411474.412.0FalseNoneNoneFalseNoneFalse2948.820
3562092129078Nonecode133Supplying and drawing UTP-CAT 6E LAN cable. 8.1Mtr47.0847.081500.0FalseNoneNoneFalseNoneFalse70620.00
3562093129078Nonecode134Supplying & Fixing of switch mounting rack with power manager & Cable manager.24U with 650mm depth 8.4.6Each38887.2538887.252.0FalseNoneNoneFalseNoneFalse77774.50
3562094129078Nonecode135Supplying fixing of Network Switches 24 port 10/100/1000 Switch 8.9.10No9187.189187.182.0FalseNoneNoneFalseNoneFalse18374.360
3562095129078Nonecode136Supplying & fixing of I/O socket with back box 8.10.1No607.11607.1125.0FalseNoneNoneFalseNoneFalse15177.750
3562096129078Nonecode137Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.1.5 Ton capacity 6.8.5No69823.8469823.844.0FalseNoneNoneFalseNoneFalse279295.360
3562097129078Nonecode138Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. 6.12No3933.823933.824.0FalseNoneNoneFalseNoneFalse15735.280
3562098129078Nonecode139Supplying and installation of insulated refrigerant copper tubing of 5/8 and 3/8 with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. Leak testing oil and gas charging for additional piping length of tube.6.13.1Mtr1919.211919.2110.0FalseNoneNoneFalseNoneFalse19192.10
3562099129078Nonecode140Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.16/6 Amps combined plug and socket with control switch 3.14.15Each270.1270.14.0FalseNoneNoneFalseNoneFalse1080.40
3562100129078Nonecode14140 kVA/32kW Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications.Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have plus or mines 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions. Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode. 10.1.5No692745.96692745.961.0FalseNoneNoneFalseNoneFalse692745.960
3562101129078Nonecode14210.2.2 40 to 50 KVASupply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage,....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.No88484.4288484.421.0FalseNoneNoneFalseNoneFalse88484.420
3562102129078Nonecode14312.57 Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.6.2 old srNo5273.185273.184.0FalseNoneNoneFalseNoneFalse21092.720
3562103129078Nonecode144Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 5.15.11 160Amps 25kA.No16660.8316660.832.0FalseNoneNoneFalseNoneFalse33321.660
3562104129078Nonecode145Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.5.29No1765.571765.572.0FalseNoneNoneFalseNoneFalse3531.140
3562105129078Nonecode146Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No696.31696.319.0FalseNoneNoneFalseNoneFalse6266.790
3562106129078Nonecode147Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No638.08638.0812.0FalseNoneNoneFalseNoneFalse7656.960
3562107129078Nonecode148Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG 5.42.1Sq CM0.610.61100000.0FalseNoneNoneFalseNoneFalse61000.00
3562108129078Nonecode149Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips 5.40.1Mtr3054.133054.133.0FalseNoneNoneFalseNoneFalse9162.390
3562109129078Nonecode150Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm 5.41.1Mtr377.89377.8940.0FalseNoneNoneFalseNoneFalse15115.60
3562110129078Nonecode151Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia 6.1 old srNo4348.894348.8920.0FalseNoneNoneFalseNoneFalse86977.80
3562111129078Nonecode152Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.6.2No5273.185273.1812.0FalseNoneNoneFalseNoneFalse63278.160
3562112129078Nonecode153Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip 12.58.2Mtr101.59101.5960.0FalseNoneNoneFalseNoneFalse6095.40
3562113129078Nonecode154Gescom sr/11KV materials/134/18.01:LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018)Each28107.9528107.951.0FalseNoneNoneFalseNoneFalse28107.950
3562114129078Nonecode155Gescom sr/11KV materials/207/32.11: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km221747.54221747.540.3FalseNoneNoneFalseNoneFalse66524.2620
3562115129078Nonecode156Gescom sr/11KV Labour/176/21.06: Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm38581.2238581.220.3FalseNoneNoneFalseNoneFalse11574.3660
3562116129078Nonecode157Vol I/1.14.1:Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)In soil (hard) 6.6.2Cum126.37126.37150.0FalseNoneNoneFalseNoneFalse18955.50
3562117129078Nonecode158Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6.17.1No3.713.71220.0FalseNoneNoneFalseNoneFalse816.20
3562118129078Nonecode159Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sqmm. (6.17.2)No4.954.95300.0FalseNoneNoneFalseNoneFalse1485.00
3562119129078Nonecode160Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4.0 sqmm. (6.17.3)No4.954.95260.0FalseNoneNoneFalseNoneFalse1287.00
3562120129078Nonecode161Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sqmm. (6.17.4)No8.678.67120.0FalseNoneNoneFalseNoneFalse1040.40
3562121129078Nonecode162Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10sqmm.(6.17.5)No9.919.9124.0FalseNoneNoneFalseNoneFalse237.840
3562122129078Nonecode163Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm. (6.17.6)No15.4115.4112.0FalseNoneNoneFalseNoneFalse184.920
3562123129078Nonecode164Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel. (6.17.9)No74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3562124129078Nonecode165Vol V/9.1.4: : Providing and fixing to wall, ceiling and floor, high density polyethylene pipes 6.00 kgf/sq.cm working pressure 110 mm outside diameter compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments & testing complete as per specificationsMtr581.09581.09300.0FalseNoneNoneFalseNoneFalse174327.00
3562125129078Nonecode166Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.5.33Each11541.2811541.281.0FalseNoneNoneFalseNoneFalse11541.280
3562126129078Nonecode167Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs.5.39Each26811.9626811.961.0FalseNoneNoneFalseNoneFalse26811.960
3562127129078Nonecode168VOl-6/KPTCL/P.No-158:Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedureCum2196.742196.742.0FalseNoneNoneFalseNoneFalse4393.480
3562128129078Nonecode169Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor.5.37Kvar594.72594.7220.0FalseNoneNoneFalseNoneFalse11894.40
3562129129078Nonecode170Gescom sr/11KV materials/536/66.04:HDPE/PLB Pipe 50/42 mmKm105332.34105332.340.14FalseNoneNoneFalseNoneFalse14746.52760
3562130129078Nonecode1715.13.1 Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.25 AmpsEach1598.311598.314.0FalseNoneNoneFalseNoneFalse6393.240
3562131129078Nonecode1725.16 Supplying and fixing of Shunt trip suitable for MCCB.CBCT.Mtr2110.012110.011.0FalseNoneNoneFalseNoneFalse2110.010
3562132129078Nonecode173Fabrication, Supplying, Erection, Testing and Commissioning of 16 Mtrs long polygon high mast with Single / Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grade S 355 JO /ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/sec as per IS 875 part 3(as per GA Drawing).Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint. The mast shall have 2way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5mmdia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5sqmm EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement. The mast shall have manual / power tool (Suitable reversible geared motor operating on 230/ 415V, 50Hz, shall be provide above 15 Mtrs mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin lamps fitting with wiring complete. (excluding foundation) as per technical data.16 mtr 4.5.2Each241605.0241605.01.0FalseNoneNoneFalseNoneFalse241605.00
3562133129078Nonecode174VOL-1/2.2.1:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7789.597789.592.87FalseNoneNoneFalseNoneFalse22356.12330
3562134129078Nonecode175VOL-1/2.1.4:Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum7702.867702.860.78FalseNoneNoneFalseNoneFalse6008.23080
3562135129078Nonecode176VOL-2/11.33:Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications.Kg113.98113.98125.0FalseNoneNoneFalseNoneFalse14247.50
3562136129078Nonecode177Gescom sr/11KV Labour/205/29.06: Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.Hard Rock/Latterite Rock latterite Soil (0.5x0.6x200)=60Cum)Cum126.37126.3710.14FalseNoneNoneFalseNoneFalse1281.39180
3562137129078Nonecode178Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT Greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK08. Power Factor Greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........W System Power consumption. LED EfficiencyGreater than130lm/w, nominal CRI Greater than75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Floodlight 11.9.6 LED Floodlight 200WNos23021.8523021.856.0FalseNoneNoneFalseNoneFalse138131.10
3562138129078Nonecode179Fixing LED floodlight fitting over existing pole including clamps, bolts, nuts and wiring using suitable capacity wires complete.(13.5)Nos200.71200.716.0FalseNoneNoneFalseNoneFalse1204.260
3562139129078Nonecode180Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.5.42.1Sq CM0.610.6114000.0FalseNoneNoneFalseNoneFalse8540.00
3562140129078Nonecode181Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting.5.47Each2868.282868.281.0FalseNoneNoneFalseNoneFalse2868.280
3562141129078Nonecode182Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 5.13.1Each1598.311598.311.0FalseNoneNoneFalseNoneFalse1598.310
3562142129078Nonecode183Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.18.7Each2127.362127.361.0FalseNoneNoneFalseNoneFalse2127.360
3562143129078Nonecode184Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. 12.56Each4348.894348.892.0FalseNoneNoneFalseNoneFalse8697.780
3562144129078Nonecode185Gescom sr/11KV materials/213/32.03: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km146206.95146206.950.3FalseNoneNoneFalseNoneFalse43862.0850
3562145129078Nonecode186Gescom sr/11KV Labour/230/31.05: Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm25877.7525877.750.3FalseNoneNoneFalseNoneFalse7763.3250
3562146129078Nonecode187Vol I/1.14.1:Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.Cum126.37126.37100.0FalseNoneNoneFalseNoneFalse12637.00
3562147129078Nonecode188Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10sqmm.(6.17.5)Each99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3562148129078Nonecode189VOL-5/10.1.4:Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 63mm dia., 6 kg/sqcm & class 3Mtr199.47199.47300.0FalseNoneNoneFalseNoneFalse59841.00
3562149129078Nonecode190Supplying, Installing & Commissioning of Grid-connected Rooftop Solar Photo-voltaic includes of Systems Solar PV panels (with domestic cell and modules), inverter (single/3 phase wherever applicable), balance of system e.g. cable,switches/ circuit breaker/ connectors/ junction box, mounting structure, earthing, lightening arrester, and civil works, installation & commissioning, CMC for 5 years, transportation,insurance, applicable taxes, etc. excluding of net metering cost and battery back-up costs.The benchmark cost for year 2021-22 will be applicable for all LoAs to be issued/empanelment of vendors to be done by the state implementing agencies, under Ph-II of rooftop solar programme of MNRE (MNRE BENCHMARK COSTS FOR GRID CONNECTED ROOFTOP SOLAR PHOTO VOLTAIC SYSTEMS FOR THE FINANCIAL YEAR 2021-22) FOR Greater than 10KW UPTO 100KWKwhr49135.249135.215.0FalseNoneNoneFalseNoneFalse737028.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17214612860000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17214612860000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17214612860000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17214612860000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17214612860000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17214621470001NoneNoneELIGIBILITYTERMS AND CONDITIONS AS PER TENDER DOCUMENTNone
17218062830000NoneNoneELIGIBILITYEstimated Rates inclusive of all applicable taxes including GST.None
17218062870000NoneNoneELIGIBILITYThe bidder shall quote their rates inclusive of all applicable taxes and inclusive of GST.None
17218062990000NoneNoneELIGIBILITYGST will not be paid separately. It is added in the individual items rates.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneUpload a Scanned copy of attested Valid contractors Registration Certificate as per tender notification Eligibility CriteriaOthersShould be valid Class-I registered Civil Prime Contractor in Karnataka. CPWD/MES/KPWD.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneUpload a Scanned copy of Single work of RCC Frame Structure BUILDING with minimum built-up area as per tender notification Eligibility CriteriaOthersSingle work of RCC Frame Structure BUILDING with minimum built-up area of 850.00 Sqm
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of Single work of RCC Frame Structure BUILDING with minimum built-up area as per tender notification Eligibility Criteria
NoneNoneNoneNoneShould have successfully completed at least one work of similar nature of building work, costing not less than Rs. 300.00 Lakhs (Rupees Three Hundred Lakhs) i.e., from 01/04/2019 onwards for any of the Govt./ Public Sector Corporate undertakings. Upload a Scanned copy of as per tender notification Eligibility CriteriaOthersShould have successfully completed at least one work of similar nature of building work
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Should have successfully completed at least one work of similar nature of building work
NoneNoneNoneNoneUpload a Scanned copy of quantities of work done as per tender notification Eligibility CriteriaOthersQuantities of work done
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Quantities of work done
NoneNoneNoneNoneUpload a Scanned copy of Annual Financial Turnover audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per tender notification Eligibility Criteria. Should have achieved a Annual Financial Turnover of Rs.1200.00 Lakhs (Rupees Twelve Hundred Lakhs) pertaining to civil works for any of 2 (Two) financial years from last preceding Five years i.e (2019-20, 2020-21, 2021-22, 2022-23 & 2023-24)OthersAnnual Financial Turnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneUpload a Scanned copy of Qualify for award of this contract the Tenderer has to furnish Liquid assets statement or availability of credit facilities as per tender notification Eligibility CriteriaOthersUpload a Scanned copy of Qualify for award
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of Qualify for award
NoneNoneNoneNoneUpload a Scanned copy of To Qualify for award of this Contract the assessed available tender capacity of the tenderer should be more than the amount put to tender as per tender notification Eligibility CriteriaOthersContract the assessed available tender capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Contract the assessed available tender capacity
NoneNoneNoneNoneWithin 20 Days of receipt of letter of acceptance, the successful bidder shall deliver to employer an amount equal to difference of sanctioned and approved bid amount in the form of D.D/ Banker cheque in favour of Executive Engineer KKRTC CE Div Ballari. The same will be refunded after completion of work. (Attach self declaration certificate)OthersPerformance security for unbalance Rates Attach self declaration certificate as per tender notification Eligibility Criteria
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Performance security for unbalance Rates Attach self declaration certificate as per tender notification Eligibility Criteria
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721809029000
version0
createdDateNone
modifiedDateNone
blockNumberCE Division, Near Siruguppa Road, Balllari
streetNone
cityBallari
stateKarnataka
pin583102
tenderRecallDTONone