createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721802551990
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd525000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-08-2024 17:00:00
tenderQueryClose26-07-2024 15:00:00
technicalBidOpen07-08-2024 11:20:00
publishedDate24-07-2024 13:59:03
publishedByPostKKRTC_EE_HOFF_BLR
publishedByUserKPE10109 - M ERESH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate29-07-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSri.M.Eresh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber8392294828
mobileNumber9972039797
tenderSupplierListNone
tenderSchedule
createdTs1721802552021
version12
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/BD/WORK_INDENT58
titleConstruction of New Ultra Modern Bus Station at Kottur
descriptionConstruction of New Ultra Modern Bus Station at Kottur
categoryWORKS
categoryTextWorks
ecv35000000.00
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5937
locationNameKKRTC Divisional Controller Office Bellari
provisionalAmount35000000.0
groupOverheadTotal1402552.4
fileNumber00029
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218025520000NoneNoneBuildingsConstruction of New Ultra Modern Bus Station at Kottur33597447.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3594726130962Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) Depth exceeding 1.5 m, but not exceeding 3 m.In all kinds of soils Depth upto 3 mCum126.37126.37851.2FalseNoneNoneFalseNoneFalse107566.1440
3594727130962Nonecode02Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.15.1) In ordinary/soft rock without blasting upto 1.5 m depth.Cum449.75449.75140.73FalseNoneNoneFalseNoneFalse63293.31750
3594728130962Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (15/2.1.2) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum7017.697017.69194.55FalseNoneNoneFalseNoneFalse1365291.58950
3594729130962Nonecode04Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.SRP- Vol-I (7/1.9)Cum329.57329.57325.64FalseNoneNoneFalseNoneFalse107321.17480
3594730130962Nonecode05KSRB 2.3 : Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP- Vol-I (7/1.10)Cum520.38520.38801.44FalseNoneNoneFalseNoneFalse417053.34720
3594731130962Nonecode06Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum7934.557934.5511.55FalseNoneNoneFalseNoneFalse91644.05250
3594732130962Nonecode07Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8478.328478.3299.68FalseNoneNoneFalseNoneFalse845118.93760
3594733130962Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum14413.4114413.4152.38FalseNoneNoneFalseNoneFalse754974.41580
3594734130962Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12717.7212717.72203.92FalseNoneNoneFalseNoneFalse2593397.46240
3594735130962Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13565.5613565.5636.12FalseNoneNoneFalseNoneFalse489988.02720
3594736130962Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12293.7912293.790.66FalseNoneNoneFalseNoneFalse8113.90140
3594737130962Nonecode12Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot ressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.SRP- Vol-II (106/12.57.4) 35 mm thick Both side teakSqm5615.145615.146.62FalseNoneNoneFalseNoneFalse37172.22680
3594738130962Nonecode13Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.SRP- Vol-II (100/12.12)Cum153886.27153886.270.2FalseNoneNoneFalseNoneFalse30777.2540
3594739130962Nonecode14VOL II /15.1 Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken protion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strenth greater than 2MPa as per ASTM D412 . The waterproofing membrance to be applied in 2 coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1 mm including prime coat of epoxy primer @ 150g/m2 and protection with 120 gsm Geo-txtile over the waterproofing membrance. The finished cost to include surface preparation, making coving at junction, Bore Packing, treatment of construction joints completely as per specification.Sqm1012.261012.26100.0FalseNoneNoneFalseNoneFalse101226.00
3594740130962Nonecode15Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (105/12.54)Rmtr394.0394.0102.6FalseNoneNoneFalseNoneFalse40424.40
3594741130962Nonecode16Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.SRP- Vol-II (104/12.55.2) with one side prelam.Sqm2527.562527.5622.05FalseNoneNoneFalseNoneFalse55732.6980
3594742130962Nonecode17VOL II SRP 106/12.55.1 Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges (both side prelam)Sqm2931.472931.476.3FalseNoneNoneFalseNoneFalse18468.2610
3594743130962Nonecode18Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/11.34A)Kg208.15208.152158.7FalseNoneNoneFalseNoneFalse449333.4050
3594744130962Nonecode19Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (85/11.34A)Sqm5383.455383.4512.6FalseNoneNoneFalseNoneFalse67831.470
3594745130962Nonecode20Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8)Cum9873.599873.59215.21FalseNoneNoneFalseNoneFalse2124895.30390
3594746130962Nonecode21Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP-Vol-2(14/6.13)Sqm1209.261209.2628.35FalseNoneNoneFalseNoneFalse34282.5210
3594747130962Nonecode22Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 Fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1)Sqm365.5365.51286.85FalseNoneNoneFalseNoneFalse470343.6750
3594748130962Nonecode23Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.1.2)Sqm315.94315.94940.64FalseNoneNoneFalseNoneFalse297185.80160
3594749130962Nonecode24Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.35.1.2/86)Kg605.87605.8787.36FalseNoneNoneFalseNoneFalse52928.80320
3594750130962Nonecode25Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.SRP-Vol-II (11.37.2/82)Sqm1450.861450.8615.3FalseNoneNoneFalseNoneFalse22198.1580
3594751130962Nonecode26Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (83/11.28)Kg700.03700.03441.0FalseNoneNoneFalseNoneFalse308713.230
3594752130962Nonecode27Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete SRP- Vol-II (71/10.15.1)Sqm4880.424880.4220.0FalseNoneNoneFalseNoneFalse97608.40
3594753130962Nonecode28Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground 2021-22 SRP- Vol-I (A-45/50)Days9356.929356.925.0FalseNoneNoneFalseNoneFalse46784.60
3594754130962Nonecode29Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.SRP- Vol-II (50/8.51)Sqm123.9123.91077.41FalseNoneNoneFalseNoneFalse133491.0990
3594755130962Nonecode30Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification.SRP- Vol-II (72/10.19)Sqm4469.074469.0767.24FalseNoneNoneFalseNoneFalse300500.26680
3594756130962Nonecode31Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming (Payment for grouting of joints to be made separately). SRP- Vol-II (62/9.22.2)Size of Tile 600x600 mmSqm1642.911642.9140.95FalseNoneNoneFalseNoneFalse67277.16450
3594757130962Nonecode32Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials,labour,curing, polishing complete as per specifications.SRP- Vol-II (64/9.34)Sqm1914.251914.25150.69FalseNoneNoneFalseNoneFalse288458.33250
3594758130962Nonecode33Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. SRP- Vol-II (72/9.24)Sqm3533.623533.6240.16FalseNoneNoneFalseNoneFalse141910.17920
3594759130962Nonecode34Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (69/10.2)Rmtr406.39406.3960.1FalseNoneNoneFalseNoneFalse24424.0390
3594760130962Nonecode35Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 126/8/T130AEach6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3594761130962Nonecode36Supplying and laying at site Factory made perforated hard HDPE subsoil drainage pipes pre-wrapped with 150gsm Geotextile for subsoil drainage system including all necessary coupling/ fittings for joints & back filling with aggregates. The pipe shall be manufactured from High Density Polyethylene (HDPE). It shall be extruded into an open lattice wall structure, with 60 percentage of the circumference consisting of open area and a 30 percentage solid area along the invert.The product should satisfy the following parameters as below 1 Ring Stiffness as per ISO 9969 2016 should be 0.8 kN/ m2 2. Resistance to Acid with 3 percentage HCl for 24 hrs without mass loss, change in colour, softening, cracking or spalling. Resistance to Alkali with 3 percentage KOH for 24hrs without without mass loss, change in colour, softening, cracking or spalling. (Excavated material to be utlised in roadway at site)SRPVol-III 19 /3.14Rmtr385.32385.3280.0FalseNoneNoneFalseNoneFalse30825.60
3594762130962Nonecode37Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 184/2.2/T040BRmtr633.12633.1235.0FalseNoneNoneFalseNoneFalse22159.20
3594763130962Nonecode38Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (48/8.40)Sqm139.39139.3925.0FalseNoneNoneFalseNoneFalse3484.750
3594764130962Nonecode39Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (48/8.25)Sqm178.1178.1250.0FalseNoneNoneFalseNoneFalse44525.00
3594765130962Nonecode40Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28)Sqm137.83137.83200.0FalseNoneNoneFalseNoneFalse27566.00
3594766130962Nonecode41Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP- Vol-I (18/2.11/a)Kg110.82110.8247803.04FalseNoneNoneFalseNoneFalse5297532.89280
3594767130962Nonecode42Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (75/11.1)Kg131.33131.335540.73FalseNoneNoneFalseNoneFalse727664.07090
3594768130962Nonecode43Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. SRP- Vol-II (26/7.38)Sqm703.75703.75190.0FalseNoneNoneFalseNoneFalse133712.50
3594769130962Nonecode44Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete SRP- Vol-II (71/10.15.1)Sqm4942.374942.3745.36FalseNoneNoneFalseNoneFalse224185.90320
3594770130962Nonecode45Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ eams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval fromstructural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts,washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glasspanel inside the SS channel shall be measured.SRP- Vol-II (160/18.7)Sqm9852.529852.5219.44FalseNoneNoneFalseNoneFalse191532.98880
3594771130962Nonecode46KSRB 7.15 :Providing , fabricating, assembling and fixing in position anodized aluminum partions using aluminium section of mat finish or glassy finish in combination of plain grove, single groove, single grove and double grove as per requirements for the frames of overall size 63.5mmx38.1mm. with thickness of 2 mm having section weight, plain sections. 1.054 kg/m, single grove thickness 1.95mm section weight. 1.094kg/m and bottom member 114.3mm x 44.45mm thickness 3.18mm weight 2.646 kg/m aluminium louvers section of size 36.5mmx34.93mm 1.45mm thick section weight 0.429kg/m bottom prortion provided with 12mm thick prelaminated sheet both sides of approved portion viz., 0.9m to 2.13m and top panel with louvers sections; the glass and panels fitted wtih glazing clips of 19mm x 17.3mm of thickness 0.9mm weight 0.13 and top panel with louvers sections; the glass and panels fitted with glazing clips of 19mmx 17.3mm of thickness 0.9mm weight 0.124kg/m aluminium setions anodised 12 to 15 microns, sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non adherence of mortars or any other sticky materials ; vertical members embedded in the flooring by making suitable sized holes and fixing with cement mortar, with necesary opening for fixing of door of standard size ( excluding cost of door ) all the frame throughly cleaned, free from rust , scale of dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specification SRP 38/7.15.2 ( Powder Coated )Sqm4049.764049.766.48FalseNoneNoneFalseNoneFalse26242.44480
3594772130962Nonecode47Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 16.9/191Each5936.045936.0410.0FalseNoneNoneFalseNoneFalse59360.40
3594773130962Nonecode48Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will makehis own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used. SRP- Vol-V 94/9.1.4Rmtr581.09581.09180.0FalseNoneNoneFalseNoneFalse104596.20
3594774130962Nonecode49Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 184/2.2/T040BRmtr719.85719.8570.0FalseNoneNoneFalseNoneFalse50389.50
3594775130962Nonecode50VOL II SRP 46/8.33.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm170.98170.98100.0FalseNoneNoneFalseNoneFalse17098.00
3594776130962Nonecode51Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (45/8.25)Sqm169.74169.741077.41FalseNoneNoneFalseNoneFalse182879.57340
3594777130962Nonecode52Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28)Sqm110.27110.271267.96FalseNoneNoneFalseNoneFalse139817.94920
3594778130962Nonecode53Providing and placing on terrace ( at all floor levels ) polyethylene water storage tanks,IS : 12701 marked,with cover and suitable locking arrangement and making necessary holes for for inlet,oulet and overflow pipes but without fittings and the base support for tank. SRP- Vol-II (12/13.34)Ltr11.1511.1510000.0FalseNoneNoneFalseNoneFalse111500.00
3594779130962Nonecode54Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 40mmMtr664.1664.1120.0FalseNoneNoneFalseNoneFalse79692.00
3594780130962Nonecode55Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 25mmMtr397.75397.7540.0FalseNoneNoneFalseNoneFalse15910.00
3594781130962Nonecode56Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 20mmMtr299.83299.8335.0FalseNoneNoneFalseNoneFalse10494.050
3594782130962Nonecode57Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 15mmMtr225.49225.4925.0FalseNoneNoneFalseNoneFalse5637.250
3594783130962Nonecode58Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work 40mm SRP- Vol-II (123/13.33.5)Mtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3594784130962Nonecode59Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work 25mm SRP- Vol-II (122/13.33.3)Mtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3594785130962Nonecode60Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work 20mm SRP- Vol-II (122/13.33.2)Mtr268.86268.8620.0FalseNoneNoneFalseNoneFalse5377.20
3594786130962Nonecode61Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes having thermal stability for hot and cold water supply incl all CPVC plain & brass threaded fittings. This incl jointing of pipes and fittings with one step CPVC solvent cement,trenching,refilling and testing of joints complete 50mm dia as pe direction of Engineer in charge External work 15mm SRP- Vol-II (122/13.33.1)Mtr205.67205.6720.0FalseNoneNoneFalseNoneFalse4113.40
3594787130962Nonecode62White Vitreous China Flat back wash basin size 550x 400 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (133/14.7.7)Nos3133.433133.432.0FalseNoneNoneFalseNoneFalse6266.860
3594788130962Nonecode63Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : SRP- Vol-II (128/14.32.3)Each1320.771320.777.0FalseNoneNoneFalseNoneFalse9245.390
3594789130962Nonecode64Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked black solid plastic seat and lid. SRP- Vol-II (123/14.3.2)Each7192.397192.396.0FalseNoneNoneFalseNoneFalse43154.340
3594790130962Nonecode65Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1:2:4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2Each336.3336.315.0FalseNoneNoneFalseNoneFalse5044.50
3594791130962Nonecode66Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP- Vol-II (117/13.5.1)Nos366.74366.7411.0FalseNoneNoneFalseNoneFalse4034.140
3594792130962Nonecode67Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3)Nos740.92740.926.0FalseNoneNoneFalseNoneFalse4445.520
3594793130962Nonecode68Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3)Nos869.77869.772.0FalseNoneNoneFalseNoneFalse1739.540
3594794130962Nonecode69Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP- Vol-II (117/13.3.1)Nos370.46370.4628.0FalseNoneNoneFalseNoneFalse10372.880
3594795130962Nonecode70Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation com plete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (76/11.6.3)Sqm2818.722818.72111.63FalseNoneNoneFalseNoneFalse314653.71360
3594796130962Nonecode71Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11)Sqm1101.471101.4782.43FalseNoneNoneFalseNoneFalse90794.17210
3594797130962Nonecode72Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38)Sqm1724.681724.68157.4FalseNoneNoneFalseNoneFalse271464.6320
3594798130962Nonecode73Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.SRP- Vol-II (65/9.40)Sqm1154.741154.7491.03FalseNoneNoneFalseNoneFalse105115.98220
3594799130962Nonecode74Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.SRP- Vol-II (63/9.25)Sqm991.2991.2100.0FalseNoneNoneFalseNoneFalse99120.00
3594800130962Nonecode75Supplying and fixing MS Chairs & 3 seater of approved qulaity including fixing in flooring drilling to the suitable holes grouting complete as per direction of Engineer in charge of work complete as per specifications with all lead and lift. (Approved rate)Nos6490.06490.040.0FalseNoneNoneFalseNoneFalse259600.00
3594801130962Nonecode76Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground SRP- Vol-I (A-45/50)hr1672.651672.6511.0FalseNoneNoneFalseNoneFalse18399.150
3594802130962Nonecode77Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials,usage& all other appurtenaces required to complete the work. SRP- Vol-I (7/1.8)Cum587.28587.281312.5FalseNoneNoneFalseNoneFalse770805.00
3594803130962Nonecode78Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. SRP- Vol-III (24/4.27)Cum3170.63170.6175.0FalseNoneNoneFalseNoneFalse554855.00
3594804130962Nonecode79Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.SRP- Vol-III (43/6.1)complete in C.C. 1:6:12 prop )Cum6095.886095.88218.75FalseNoneNoneFalseNoneFalse1333473.750
3594805130962Nonecode80Construction of M40 grade un-reinforced,Cement Concrete Pavement with OPC/PPC/PSC dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing SRP- Vol-III (43/6.2)Cum11226.5711226.57350.0FalseNoneNoneFalseNoneFalse3929299.50
3594806130962Nonecode81Supplying, fitting and placing un-coated Mild steel reinforcement complete in foundation as per drawing and technical specification. SRP- Vol-I (18/2.12)Kg91.3391.3314000.0FalseNoneNoneFalseNoneFalse1278620.00
3594807130962Nonecode82Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.7)Rmtr509.22509.2260.0FalseNoneNoneFalseNoneFalse30553.20
3594808130962Nonecode83Korean truff (Bijapur BS Approved Rate)Sqm206.5206.550.0FalseNoneNoneFalseNoneFalse10325.00
3594809130962Nonecode84Providing & supplying of plants from forest department of plants size 14" x 20" with supporting guard stick including transportation loading unloading placeing the plants in pits of 1 Mtr x 1 Mtr x 1 Mtr of size pits and refiling of required quantity and watering etc., complete.Each118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3594810130962Nonecode85Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30)Sqm6601.396601.396.75FalseNoneNoneFalseNoneFalse44559.38250
3594811130962Nonecode86White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (133/14.7.7)Nos2600.662600.663.0FalseNoneNoneFalseNoneFalse7801.980
3594812130962Nonecode87White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. SRP- Vol-II (126/14.13.2)Nos2888.12888.16.0FalseNoneNoneFalseNoneFalse17328.60
3594813130962Nonecode88VOL II 124/14.5.1 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Each10707.4310707.438.0FalseNoneNoneFalseNoneFalse85659.440
3594814130962Nonecode89Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7651.28FalseNoneNoneFalseNoneFalse431406.33280
3594815130962Nonecode90Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13964.7613964.7616.59FalseNoneNoneFalseNoneFalse231675.36840
3594816130962Nonecode91Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12321.8512321.8522.78FalseNoneNoneFalseNoneFalse280691.7430
3594817130962Nonecode92Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.1)Sqm345.68345.68668.99FalseNoneNoneFalseNoneFalse231256.46320
3594818130962Nonecode93Providing patti allround compound wall etc, with CM 1:3 and finished as per design and specification including scafolding etc, complete. Patti 10cm wide and 10 mm thick.Kg14.0114.01297.66FalseNoneNoneFalseNoneFalse4170.21660
3594819130962Nonecode94Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13143.3113143.3129.34FalseNoneNoneFalseNoneFalse385624.71540
3594820130962Nonecode95Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12321.8512321.8518.33FalseNoneNoneFalseNoneFalse225859.51050
3594821130962Nonecode96Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 0 to 50 m SRP- Vol-V (139/12.2.1)Rmtr382.85382.8560.0FalseNoneNoneFalseNoneFalse22971.00
3594822130962Nonecode97Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 50 to 100 m SRP- Vol-V (139/12.2.2)Rmtr479.49479.4930.0FalseNoneNoneFalseNoneFalse14384.70
3594823130962Nonecode98Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing ofcasing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for Borewell depth of 100 to 150 m SRP- Vol-V (139/12.2.3)Rmtr510.46510.4660.0FalseNoneNoneFalseNoneFalse30627.60
3594824130962Nonecode99Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 134/1.9)Rmtr742.16742.1620.0FalseNoneNoneFalseNoneFalse14843.20
3594825130962Nonecode100Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes andspecials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 SRP- Vol-V 113/10.1.8)Rmtr723.57723.5740.0FalseNoneNoneFalseNoneFalse28942.80
3594826130962Nonecode101Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. 5 O050A Cleaning of borewells including yield.VOL-V 139/12.2Each6239.846239.841.0FalseNoneNoneFalseNoneFalse6239.840
3594827130962Nonecode102SRP:1.2 Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe 25 mm dia 2 .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick 1.2.2Mtr96.6496.64300.0FalseNoneNoneFalseNoneFalse28992.00
3594828130962Nonecode103SRP: 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr97.8897.88300.0FalseNoneNoneFalseNoneFalse29364.00
3594829130962Nonecode1041.1.2 Open Conduit System:Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr100.35100.3580.0FalseNoneNoneFalseNoneFalse8028.00
3594830130962Nonecode105SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm 2.3.2Mtr32.2132.211500.0FalseNoneNoneFalseNoneFalse48315.00
3594831130962Nonecode106SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmm (P6/2.3.3)Mtr52.0352.031800.0FalseNoneNoneFalseNoneFalse93654.00
3594832130962Nonecode107SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4sqmm (P6/2.3.4)Mtr78.0578.05600.0FalseNoneNoneFalseNoneFalse46830.00
3594833130962Nonecode108SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 6sqmm (P6/2.3.5)Mtr113.98113.98100.0FalseNoneNoneFalseNoneFalse11398.00
3594834130962Nonecode109SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 10sqmm (P6/2.3.6)Mtr206.91206.9160.0FalseNoneNoneFalseNoneFalse12414.60
3594835130962Nonecode110SRP:2.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 16sqmm(P6/2.3.7)Mtr394.0394.060.0FalseNoneNoneFalseNoneFalse23640.00
3594836130962Nonecode111SRP:2.2.1 Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo333.29333.2930.0FalseNoneNoneFalseNoneFalse9998.70
3594837130962Nonecode112SRP:2.2.1 Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2)No469.58469.5842.0FalseNoneNoneFalseNoneFalse19722.360
3594838130962Nonecode113SRP:2.2.1 Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3)No687.64687.6490.0FalseNoneNoneFalseNoneFalse61887.60
3594839130962Nonecode114Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-3 Way 3.4.1No170.98170.9820.0FalseNoneNoneFalseNoneFalse3419.60
3594840130962Nonecode115Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1- 4-5way (P15/3.4.3)No219.3219.315.0FalseNoneNoneFalseNoneFalse3289.50
3594841130962Nonecode116Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1- 6 way (P15/3.4.4)No272.58272.5820.0FalseNoneNoneFalseNoneFalse5451.60
3594842130962Nonecode117Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1- 10-12 way (P15/3.4.6)No395.24395.2440.0FalseNoneNoneFalseNoneFalse15809.60
3594843130962Nonecode118Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1- 18 way (P15/3.4.8)No501.79501.794.0FalseNoneNoneFalseNoneFalse2007.160
3594844130962Nonecode119Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module 3.5.1No169.74169.7420.0FalseNoneNoneFalseNoneFalse3394.80
3594845130962Nonecode120Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module (P16/3.5.3)No216.82216.8215.0FalseNoneNoneFalseNoneFalse3252.30
3594846130962Nonecode121Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module (P16/3.5.4)No289.92289.9220.0FalseNoneNoneFalseNoneFalse5798.40
3594847130962Nonecode122Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (P16/3.5.6)No426.21426.2140.0FalseNoneNoneFalseNoneFalse17048.40
3594848130962Nonecode123Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18 Module (P16/3.5.8)No566.22566.224.0FalseNoneNoneFalseNoneFalse2264.880
3594849130962Nonecode124Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1No126.37126.37400.0FalseNoneNoneFalseNoneFalse50548.00
3594850130962Nonecode125Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3 way socket (P16/3.6.3)No211.86211.86120.0FalseNoneNoneFalseNoneFalse25423.20
3594851130962Nonecode126Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. modular stepped fan regulator (P16/3.6.4)No442.32442.3212.0FalseNoneNoneFalseNoneFalse5307.840
3594852130962Nonecode127Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch (P16/3.6.7)No223.02223.0211.0FalseNoneNoneFalseNoneFalse2453.220
3594853130962Nonecode128Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal socket (P16/3.6.10)No292.4292.411.0FalseNoneNoneFalseNoneFalse3216.40
3594854130962Nonecode129Supplying and fixing Fan box with round hook (P3/1.13)No144.96144.9612.0FalseNoneNoneFalseNoneFalse1739.520
3594855130962Nonecode130Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2Mtr27.2527.2550.0FalseNoneNoneFalseNoneFalse1362.50
3594856130962Nonecode131Supplying of ......feet - PVC Batten with integrated LED tube ..W with high quality diffuser with Life of 25000 burning hours & 70 percentage lumen maintenance with CRI grater than 80. Power Input: 220-240V @ 50/60Hz & Power factor grater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fighting 1 x4'- 20/22 wNo854.91854.9150.0FalseNoneNoneFalseNoneFalse42745.50
3594857130962Nonecode132Supply of round or square recess or surface mounted rolling type LED Down light with ....W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70 percentage lumen maintenance with CRI grater then 80. Power Input: 220-240V @ 50 or 60Hz & Power factor grater then 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W 11.5.3No1640.431640.435.0FalseNoneNoneFalseNoneFalse8202.150
3594858130962Nonecode133Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI grater than 70%. Efficacy grater than 100 lumen per watt, 120degree beam spread, life grater than 25000 burning hours and Compliance to IS 10322or IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF or 0.95, power loss should less than 5 percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20 percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL or CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' / 1' x 4' 34 -36watt 12.6.2No5641.165641.162.0FalseNoneNoneFalseNoneFalse11282.320
3594859130962Nonecode134Supply of LED Streetlight luminaire 90 watt with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT grater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire grater than IK08. Power Factor grater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage or Overload, short circuit or miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 or 60Hz application. Compliance to IS 10322 or IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency grater than 130lm or w, nominal CRI grater than 75. Luminaire manufacturer should have in-house facility accredited by NABL or CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 Watts 11.8.4No10977.5410977.5410.0FalseNoneNoneFalseNoneFalse109775.40
3594860130962Nonecode135Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 6.3.1.No3697.173697.1710.0FalseNoneNoneFalseNoneFalse36971.70
3594861130962Nonecode136Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm) 7.2.1 (6.2.1:)No3678.593678.596.0FalseNoneNoneFalseNoneFalse22071.540
3594862130962Nonecode137Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders 13.7.1No151.15151.15110.0FalseNoneNoneFalseNoneFalse16626.50
3594863130962Nonecode138Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe 13.2.3No1831.241831.2410.0FalseNoneNoneFalseNoneFalse18312.40
3594864130962Nonecode139Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.6.5.1:No3087.583087.581.0FalseNoneNoneFalseNoneFalse3087.580
3594865130962Nonecode140Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.13.10No211.86211.8610.0FalseNoneNoneFalseNoneFalse2118.60
3594866130962Nonecode141Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.13.13No875.97875.976.0FalseNoneNoneFalseNoneFalse5255.820
3594867130962Nonecode142Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SPNo514.18514.1840.0FalseNoneNoneFalseNoneFalse20567.20
3594868130962Nonecode143Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32 Amps DP. (5.18.2)No915.62915.6220.0FalseNoneNoneFalseNoneFalse18312.40
3594869130962Nonecode144Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32 Amps TPN. (5.18.7)No2127.362127.365.0FalseNoneNoneFalseNoneFalse10636.80
3594870130962Nonecode145Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 50-63Amps TPN . (5.18.9)No3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3594871130962Nonecode146Supplying & fixing retrofit type -PL- LED Lamp ..W LED linear source with CCT 6500 degree K, CRI grater than 70 percentage. efficacy grater than 80 lumen per watt, life grater than 25000 burning hours and Compliance to IS 10322 or IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF grater than 0.95, power loss should less than 5 percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL or CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.2.1Each771.89771.893.0FalseNoneNoneFalseNoneFalse2315.670
3594872130962Nonecode147Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (Icu = Ics) 5.14.9 160Amps 25kA.No16660.8316660.832.0FalseNoneNoneFalseNoneFalse33321.660
3594873130962Nonecode148Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. 5.30:No1709.821709.828.0FalseNoneNoneFalseNoneFalse13678.560
3594874130962Nonecode149Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.5.29No1765.571765.572.0FalseNoneNoneFalseNoneFalse3531.140
3594875130962Nonecode150Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No696.31696.319.0FalseNoneNoneFalseNoneFalse6266.790
3594876130962Nonecode151Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No638.08638.0812.0FalseNoneNoneFalseNoneFalse7656.960
3594877130962Nonecode152Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG 5.42.1Sq CM0.610.61160000.0FalseNoneNoneFalseNoneFalse97600.00
3594878130962Nonecode153Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips 5.40.1Mtr3054.133054.132.0FalseNoneNoneFalseNoneFalse6108.260
3594879130962Nonecode154Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm 5.41.1Mtr377.89377.8915.0FalseNoneNoneFalseNoneFalse5668.350
3594880130962Nonecode155Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia 12.56:No4348.894348.8913.0FalseNoneNoneFalseNoneFalse56535.570
3594881130962Nonecode156Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. 12.57:No5273.185273.1810.0FalseNoneNoneFalseNoneFalse52731.80
3594882130962Nonecode15712.58.2 Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip.Mtr101.59101.5960.0FalseNoneNoneFalseNoneFalse6095.40
3594883130962Nonecode158Gescom sr/11KV materials/134/18.01:LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018)Each28107.9528107.951.0FalseNoneNoneFalseNoneFalse28107.950
3594884130962Nonecode159Gescom sr/11KV materials/207/32.11: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km221747.54221747.540.1FalseNoneNoneFalseNoneFalse22174.7540
3594885130962Nonecode160Gescom sr/11KV Labour/176/21.06: Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm38581.2238581.220.1FalseNoneNoneFalseNoneFalse3858.1220
3594886130962Nonecode161Vol I/1.14.1:Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum126.37126.3770.0FalseNoneNoneFalseNoneFalse8845.90
3594887130962Nonecode162Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sqmm 6.17.1No3.713.71177.0FalseNoneNoneFalseNoneFalse656.670
3594888130962Nonecode163Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 2.5 sqmm. (6.17.2)No4.954.95220.0FalseNoneNoneFalseNoneFalse1089.00
3594889130962Nonecode164Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 4.0 sqmm. (6.17.3)No8.678.6760.0FalseNoneNoneFalseNoneFalse520.20
3594890130962Nonecode165Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 6 sqmm. (6.17.4)No8.678.6724.0FalseNoneNoneFalseNoneFalse208.080
3594891130962Nonecode166Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10sqmm.(6.17.5)No9.919.9124.0FalseNoneNoneFalseNoneFalse237.840
3594892130962Nonecode167Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 16 sqmm. (6.17.6)No15.4115.4112.0FalseNoneNoneFalseNoneFalse184.920
3594893130962Nonecode168Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 50 sqmm Long Barrel. (6.17.9)No74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3594894130962Nonecode169VOL-5/10.1.4 Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 63mm dia., 6 kg/sqcm & class 3Mtr199.47199.4798.5FalseNoneNoneFalseNoneFalse19647.7950
3594895130962Nonecode170Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.5.33Each11541.2811541.282.0FalseNoneNoneFalseNoneFalse23082.560
3594896130962Nonecode171VOl-6/KPTCL/P.No-158:Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete.Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedureCum2196.742196.741.0FalseNoneNoneFalseNoneFalse2196.740
3594897130962Nonecode172Gescom sr/11KV materials/ 536/ 66.04:HDPE/PLB Pipe 50/42 mmKm105332.34105332.340.1FalseNoneNoneFalseNoneFalse10533.2340
3594898130962Nonecode173PWD SR/Vol-5/13.11.5: Providing, supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP 3.00 HP - 90 LPM @ 66 m = 6 STG Outlet Dia - 2.00”Each34832.034832.01.0FalseNoneNoneFalseNoneFalse34832.00
3594899130962Nonecode174PWD SR/Vol-5/12.28:Labour charges for Erection of new / repaired submersible pump set along with GI pipes (32mm / 50mm), cable (New submersible pump set if required will be supplied by the department free of cost and released pump set should be handed over to department) including transportation (Each length = 6 m)Job231.69231.6915.0FalseNoneNoneFalseNoneFalse3475.350
3594900130962Nonecode1752.6.2 Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010.Mtr208.15208.15140.0FalseNoneNoneFalseNoneFalse29141.00
3594901130962Nonecode1765.1 Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP.Each2387.552387.551.0FalseNoneNoneFalseNoneFalse2387.550
3594902130962Nonecode177Gescom SR/SSM 11KV/88/12.04:Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 63 kVA, Aluminum Wdg, Star 2 (5 Star)No226173.25226173.251.0FalseNoneNoneFalseNoneFalse226173.250
3594903130962Nonecode178Gescom SR/11KV Labour/72/8.01: Erection of 25 to 63 kVA Transformer on Transformer StructureNo1478.121478.121.0FalseNoneNoneFalseNoneFalse1478.120
3594904130962Nonecode179Gescom SR/SSM 11KV/1/1.01:RCC Pole - 9 Mtr Long, 145 Kg WLNo8767.168767.165.0FalseNoneNoneFalseNoneFalse43835.80
3594905130962Nonecode180Gescom SR/11KV Labour/30/2.02:Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depthNo1379.01379.05.0FalseNoneNoneFalseNoneFalse6895.00
3594906130962Nonecode181Gescom SR/SSM 11KV/11/2.01:11 kV, Horizontal Cross Arm - Mild Steel (MS)(Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018)No460.9460.910.0FalseNoneNoneFalseNoneFalse4609.00
3594907130962Nonecode182Gescom SR/11KV Labour/51/5.03:Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixingNo318.42318.4210.0FalseNoneNoneFalseNoneFalse3184.20
3594908130962Nonecode183Gescom SR/SSM 11KV/47/6.01:11 kV Ceramic Pin Insulator (Shell only)No102.83102.8330.0FalseNoneNoneFalseNoneFalse3084.90
3594909130962Nonecode184Gescom SR/SSM 11KV/55/6.09:DISC Insulator 45 kN PorcelainNo631.89631.8915.0FalseNoneNoneFalseNoneFalse9478.350
3594910130962Nonecode185Gescom SR/SSM 11KV/166/24.01:11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018)No11708.5511708.551.0FalseNoneNoneFalseNoneFalse11708.550
3594911130962Nonecode186Gescom SR/11KV Labour/97/13.02:Fixing of GOS including wiring (11 kV Single Break 200 Amps)No1367.851367.851.0FalseNoneNoneFalseNoneFalse1367.850
3594912130962Nonecode187Gescom SR/SSM 11KV/39/5.09, 5.11, 5.12, 5.13, 5.14, 5.16: Guy Clamp - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)Turn Buckle (GI) (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)Anchor Rod using 12 mm rounds/Guy Rod - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018)MS Fish Plate Strain Clamp, 3 Bolt type for 70/90 kN Disc InsulatorNo2106.32106.36.0FalseNoneNoneFalseNoneFalse12637.80
3594913130962Nonecode188Gescom SR/11KV Labour/58/5.10:Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)No329.57329.576.0FalseNoneNoneFalseNoneFalse1977.420
3594914130962Nonecode189Gescom SR/SSM 11KV/137/19.01: 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)Set1139.881139.881.0FalseNoneNoneFalseNoneFalse1139.880
3594915130962Nonecode190Gescom SR/11KV Labour/101/13.06:Fixing of 3 Nos Lightning Arrestor including wiringSet147.44147.441.0FalseNoneNoneFalseNoneFalse147.440
3594916130962Nonecode191Gescom SR/SSM 11KV/139/20.01:11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)Set1324.491324.491.0FalseNoneNoneFalseNoneFalse1324.490
3594917130962Nonecode192Gescom SR/11KV Labour/96/ 13.01:Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiringSet293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3594918130962Nonecode19315.111 Supplying of four bucket stand alongwith buckets. CompleteNo2292.152292.152.0FalseNoneNoneFalseNoneFalse4584.30
3594919130962Nonecode19415.117 Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick.complete including cost of materials, labour, usage charges of machinery complete as per specifications.No2354.12354.12.0FalseNoneNoneFalseNoneFalse4708.20
3594920130962Nonecode19515.113 Supplying of Hand gloves. completePair1208.021208.022.0FalseNoneNoneFalseNoneFalse2416.040
3594921130962Nonecode19615.114 Supplying of first aid box. completeNo743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3594922130962Nonecode19715.116 Supplying of FIRST AID CHART with lamination. CompleteNo495.6495.62.0FalseNoneNoneFalseNoneFalse991.20
3594923130962Nonecode198Ges SR/SSM 11KV/593/68.17: Caution/ Danger BoardNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3594924130962Nonecode19921-22/Vol-4/Part-B/Lift Irrigation/4.41 Providing and fixing chain link fencing consisting of 3 m long 65 x 65 x 6 mm M.S angles with top 50 cm bent at 30 degree to vertical fixed at 2.5 m intervals in C.C 1 : 3 : 6 proportion using 20 mm down graded coarse aggregate for 70 cm depth, fixing 50 x 50 mm opening 8 gauge G.I chain link mesh upto 1.8 m height of poles using 8 gauge stretcher wire at top and bottom and 30 x 30 x 5 mm M.S angles with bolts /nuts / washers ( 4 bolts for each pole ), fixing 3 rows of 12 gauge ( 4 barbs at 7.5 cm c/c ) G.I barbed wire for top bent portion of poles, including cost of all materials, machinery, labour, excavation of pit, mixing and laying concrete, curing, drilling holes in angles, cleaning angles, painting angles and Chain links with 2 coats of synthetic enamel paint over a coat of primer etc., complete with all lead and lifts.Sqm per Meter1704.861704.8624.0FalseNoneNoneFalseNoneFalse40916.640
3594925130962Nonecode2005.20.2 Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 A 2 poleNo5648.65648.61.0FalseNoneNoneFalseNoneFalse5648.60
3594926130962Nonecode2015.20.2 Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 Amps 4 pole (5.20.3)No6514.666514.661.0FalseNoneNoneFalseNoneFalse6514.660
3594927130962Nonecode202Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.5.19.6 4Way SP &NNo1888.231888.2320.0FalseNoneNoneFalseNoneFalse37764.60
3594928130962Nonecode203Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure 8way SP &N.(5.19.8) Double door.No2297.12297.12.0FalseNoneNoneFalseNoneFalse4594.20
3594929130962Nonecode204Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure 12way SP &N. (5.19.9) Double door.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3594930130962Nonecode2055.29 Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.No1765.571765.571.0FalseNoneNoneFalseNoneFalse1765.570
3594931130962Nonecode206Supplying, fixing and wiring 50/5Amps to 400/5 Amps 5VA burden current transformer. 0.5 accuracy. (5.34)No696.31696.316.0FalseNoneNoneFalseNoneFalse4177.860
3594932130962Nonecode207Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v AC 50Hz 12/24v DC (5.38)No638.08638.086.0FalseNoneNoneFalseNoneFalse3828.480
3594933130962Nonecode208PWD SR/Vol-2/11.16.1 Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg168.5168.5340.0FalseNoneNoneFalseNoneFalse57290.00
3594934130962Nonecode20912.57 Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.12.57No5273.185273.184.0FalseNoneNoneFalseNoneFalse21092.720
3594935130962Nonecode210Gescom SR/SSM 11KV/61/8.02:8 SWG GI Wire (4.064 mm Dia), Std Wt: 131 Kg/KMKm92974.5692974.560.04FalseNoneNoneFalseNoneFalse3718.98240
3594936130962Nonecode211Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI strip 12.58.1Mtr101.59101.5920.0FalseNoneNoneFalseNoneFalse2031.80
3594937130962Nonecode212Gescom sr/SSM 11KV/207/32.11: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km221747.54221747.540.3FalseNoneNoneFalseNoneFalse66524.2620
3594938130962Nonecode213Gescom sr/11KV Labour/176/21.06: Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm38581.2238581.220.3FalseNoneNoneFalseNoneFalse11574.3660
3594939130962Nonecode214Vol I/1.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum126.37126.37300.0FalseNoneNoneFalseNoneFalse37911.00
3594940130962Nonecode215Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.1 (2019-20 SR)No3.713.7160.0FalseNoneNoneFalseNoneFalse222.60
3594941130962Nonecode216Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sqmm. (6.17.2) (2019-20 SR)No4.954.9580.0FalseNoneNoneFalseNoneFalse396.00
3594942130962Nonecode217Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4.0 sqmm. (6.17.3) (2019-20 SR)No8.678.6724.0FalseNoneNoneFalseNoneFalse208.080
3594943130962Nonecode218Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sqmm. (6.17.4) (2019-20 SR)No8.678.6724.0FalseNoneNoneFalseNoneFalse208.080
3594944130962Nonecode219Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10sqmm.(6.17.5) (2019-20 SR)No9.919.9124.0FalseNoneNoneFalseNoneFalse237.840
3594945130962Nonecode220Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm. (6.17.6) (2019-20 SR)No15.4115.4112.0FalseNoneNoneFalseNoneFalse184.920
3594946130962Nonecode221Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel. (6.17.9) (2019-20 SR)No74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3594947130962Nonecode222Vol V/191/16.9 onstructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.No6757.56757.56.0FalseNoneNoneFalseNoneFalse40545.00
3594948130962Nonecode223Vol V/10.1.8 Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete 110mmMtr509.22509.22120.0FalseNoneNoneFalseNoneFalse61106.40
3594949130962Nonecode224Vol II/09/5.4 (Size stone masonry) Construction of Platform with size stone, cement concrete for errection of Transformer/Metering Cubicle /Heavy equipment. Construction of platform [1.5m x 1.5m x 1.2m] in size srone , for errection of transformer /Heavy equipment including all materials , labour Excavation of [1.5mx1.5mx1m] pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10cm thick layers, well compacted curing etc, complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 Providing and Laying cement concrete slab 1.5x1.5x.10mtr with cement concrete of 1:2:4 mix forming & cutting complete , providing pointing to stone masonary in cement morter 1:3 after rackng joint & nisely lining curing etc, plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc, curing at every stages completely.Cum7915.977915.971.0FalseNoneNoneFalseNoneFalse7915.970
3594950130962Nonecode225Gescom SR/SSM 11KV/398/53.04:LT AC 3 Phase 4 Wire, 5-30 Amps DLMS Complaint Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations up to 25HP/18KW)Each2948.822948.821.0FalseNoneNoneFalseNoneFalse2948.820
3594951130962Nonecode2264.1.1 Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7.Erection of heavy duty Pole on Footpath/median 9m (5m Hb,165.1 mm dia 4.85 mm thick x 2m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 32No19204.519204.53.0FalseNoneNoneFalseNoneFalse57613.50
3594952130962Nonecode22712.8.4 Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT grater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire grater than IK08. Power Factor grater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency grater than 130lm/w, nominal CRI grater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 WattsNo10977.5410977.542.0FalseNoneNoneFalseNoneFalse21955.080
3594953130962Nonecode228Gescom sr/SSM 11KV/198/32.02: 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)Km98168.4498168.440.1FalseNoneNoneFalseNoneFalse9816.8440
3594954130962Nonecode229Gescom sr/11KV Labour/175/21.05: Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3594955130962Nonecode230Vol I/1.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1Cum126.37126.37200.0FalseNoneNoneFalseNoneFalse25274.00
3594956130962Nonecode231Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.6.17.5 (2019-20 SR)10sqmm.No9.919.9180.0FalseNoneNoneFalseNoneFalse792.80
3594957130962Nonecode232Vol V/10.1.8 Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete 110mmMtr509.22509.22140.0FalseNoneNoneFalseNoneFalse71290.80
3594958130962Nonecode233PWD SR/2023-24/Vol-II/Material Components/A-12/ii/23: Aluminium Composite of approved colour straight portion.Sqm3717.03717.010.0FalseNoneNoneFalseNoneFalse37170.00
3594959130962Nonecode234PWD SR/2023-24/Vol-II/7.64.1.1:Aluminium fluted strips 3.15 mm thick.150 mm wide (but used 50 mm wide hence Rs.557/3=185.66 taken)Mtr230.02230.0280.0FalseNoneNoneFalseNoneFalse18401.60
3594960130962Nonecode235PWD SR/2023-24/Vol-II/10.15.1 Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., completeCum4942.374942.378.0FalseNoneNoneFalseNoneFalse39538.960
3594961130962Nonecode2365.41.4 Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 100 x 50 x 6 mm C channel (but used 25x50 mm square pipe) hence 0.65 takenMtr608.84608.8436.0FalseNoneNoneFalseNoneFalse21918.240
3594962130962Nonecode2375.47 Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.) 3-120sec setting.Each2868.282868.281.0FalseNoneNoneFalseNoneFalse2868.280
3594963130962Nonecode2385.13.2 Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.40 AEach2797.662797.661.0FalseNoneNoneFalseNoneFalse2797.660
3594964130962Nonecode239PWD SR/2023-24/Vol-I/A-40/77:Mild Steel Tubes 14 guage 1" x 1" squire pipeKg74.3474.34160.0FalseNoneNoneFalseNoneFalse11894.40
3594965130962Nonecode240PWD SR/2023-24/Vol-III/8.7/801:Direction and Place Identification Signs upto 0.9 m2 Size Board.Providing and erecting direction and place identification retroreflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawingSqm per Meter11163.3911163.394.2FalseNoneNoneFalseNoneFalse46886.2380
3594966130962Nonecode241PWD SR/2023-24/Vol-II/11.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg700.03700.0360.0FalseNoneNoneFalseNoneFalse42001.80
3594967130962Nonecode242PWD SR/2023-24/Vol-III/8.43:Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 cm2 on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than19 +/- 2 mm and height not less than30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be bydrilling holes on the road for the shanks to go inside,without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.Each452.23452.2340.0FalseNoneNoneFalseNoneFalse18089.20
3594968130962Nonecode243PWD SR/2023-24/Vol-III/8.45:Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 cm2 on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and coreshell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process.The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of be fixed by a combination of epoxy adhesive and grouting as per MoRTH specification 806Each3593.13593.14.0FalseNoneNoneFalseNoneFalse14372.40
3594969130962Nonecode244PWD SR/2023-24/Vol-III/8.15:Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 g/m2 area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35:2015.The finished surface to be level,uniform and free from streaks and holes.Sqm per Meter656.67656.6780.0FalseNoneNoneFalseNoneFalse52533.60
3594970130962Nonecode245PWD SR/2023-24/Vol-III/8.53:Providing & fixing Polymer rubberised factory made Black & Yellow coloured Speed retarders/Breakers with width 350mm & Height 50mm as per IRC 99:2018 with load carrying capacity upto 30t in local streets, parking arena and in areas with speed limit of 20 kmph as per direction of Engineer in-charge.Mtr1115.11115.136.0FalseNoneNoneFalseNoneFalse40143.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218025530000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218025530000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218025530000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17218025530000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218025530000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218073530000NoneNoneELIGIBILITYEstimated Rates inclusive of all applicable taxes including GST.None
17218073580000NoneNoneELIGIBILITYThe bidder shall quote their rates inclusive of all applicable taxes and inclusive of GST.None
17218073620000NoneNoneELIGIBILITYGST will not be paid separately. It is added in the individual items rates.None
17218073690000NoneNoneELIGIBILITYTERMS AND CONDITIONS AS PER TENDER NOTIFICATIONNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneUpload a Scanned copy of attested Valid contractors Registration Certificate as per tender notification Eligibility CriteriaOthersShould be valid Class-I registered Civil Prime Contractor in Karnataka.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Should be valid Class-I registered Civil Prime Contractor in Karnataka.
NoneNoneNoneNoneUpload a Scanned copy of Single work of RCC Frame Structure BUILDING with minimum built-up area as per tender notification Eligibility CriteriaOthersSingle work of RCC Frame Structure BUILDING with minimum built-up area
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Single work of RCC Frame Structure BUILDING with minimum built-up area
NoneNoneNoneNoneUpload a Scanned copy of work done one work of similar nature of building work as per tender notification Eligibility CriteriaOthersWork Done Certificate of completion
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work Done Certificate of completion
NoneNoneNoneNoneUpload a Scanned copy of quantities of work done as per tender notification Eligibility CriteriaOthersMinimum Quantity wise work done
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Minimum Quantity wise work done
NoneNoneNoneNoneUpload a Scanned copy of Annual Financial Turnover audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per tender notification Eligibility CriteriaOthersAnnual Financial Turnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Financial Turnover
NoneNoneNoneNoneUpload a Scanned copy of Qualify for award of this contract the Tenderer has to furnish Liquid assets statement or availability of credit facilities as per tender notification Eligibility CriteriaOthersQualify for award of this contract the Tenderer has to furnish Liquid assets statement
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Qualify for award of this Contract the assessed available tender capacity
NoneNoneNoneNoneUpload a Scanned copy of self declaration certificate as per tender notification Eligibility CriteriaOthersPerformance security for unbalance Rates
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Upload a Scanned copy of self declaration certificate as per tender notification Eligibility Criteria
NoneNoneNoneNoneUpload a Scanned copy of To Qualify for award of this Contract the assessed available tender capacity of the tenderer should be more than the amount put to tender as per tender notification Eligibility CriteriaOthersQualify for award of this Contract the assessed available tender capacity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Qualify for award of this Contract the assessed available tender capacity
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721807721000
version0
createdDateNone
modifiedDateNone
blockNumberO/o the EE KKRTC Near SP Circle Ballari
streetNone
cityBallari
stateKarnataka
pin583102
tenderRecallDTONone