createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721808423496
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1052000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 16:00:00
tenderQueryClose14-08-2024 16:00:00
technicalBidOpen27-08-2024 16:01:00
publishedDate24-07-2024 13:51:20
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate19-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9686183379
tenderSupplierListNone
tenderSchedule
createdTs1721808423526
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT542
titleConstruction of primary health centre at Bisilahalli in Ballari taluk in Ballari district and Construction of primary health centre at metri in kampli taluk in Ballari district
descriptionConstruction of primary health centre at Bisilahalli in Ballari taluk in Ballari district and Construction of primary health centre at metri in kampli taluk in Ballari district.
categoryWORKS
categoryTextWorks
ecv70107335.12
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount80000000.0
groupOverheadTotal0.0
fileNumberAEE/BALLARI/KKRDB
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218084240000NoneNoneBuildingsConstruction of primary health centre at Bisilahalli in Ballari taluk in Ballari district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3598409131010NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3598410131010NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3598411131010NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3598412131010NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3598413131010NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3598414131010NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3598415131010NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3598416131010NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3598417131010NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3598418131010NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3598419131010NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3598420131010NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3598421131010NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3598422131010NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3598423131010NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3598424131010NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3598425131010NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3598426131010NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3598427131010NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3598428131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3598429131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3598430131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3598431131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3598432131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3598433131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3598434131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3598435131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3598436131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3598437131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3598438131010NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3598439131010NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3598440131010NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3598441131010NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3598442131010NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3598443131010NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3598444131010NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3598445131010NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3598446131010NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3598447131010NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3598448131010NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3598449131010NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3598450131010NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3598451131010NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3598452131010NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3598453131010NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3598454131010NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3598455131010NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3598456131010NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3598457131010NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3598458131010NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3598459131010NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3598460131010NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3598461131010NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3598462131010NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3598463131010NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3598464131010NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3598465131010NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3598466131010NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3598467131010NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3598468131010NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3598469131010NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3598470131010NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3598471131010NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3598472131010NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3598473131010NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3598474131010NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3598475131010NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3598476131010NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3598477131010NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3598478131010NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3598479131010NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3598480131010NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3598481131010NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3598482131010NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3598483131010NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3598484131010NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3598485131010NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3598486131010NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3598487131010NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3598488131010NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3598489131010NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3598490131010NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3598491131010NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3598492131010NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3598493131010NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3598494131010NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3598495131010NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3598496131010NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3598497131010NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3598498131010NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3598499131010NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3598500131010NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3598501131010NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3598502131010NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3598503131010NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3598504131010NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3598505131010NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3598506131010NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3598507131010NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3598508131010NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3598509131010NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3598510131010NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3598511131010NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3598512131010NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3598513131010NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3598514131010NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3598515131010NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3598516131010NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3598517131010NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3598518131010NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3598519131010NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3598520131010NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3598521131010NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3598522131010NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3598523131010NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3598524131010NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3598525131010NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3598526131010NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3598527131010NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3598528131010NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3598529131010NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3598530131010NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3598531131010NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3598532131010NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3598533131010NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3598534131010NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3598535131010NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3598536131010NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3598537131010NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3598538131010NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3598539131010NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3598540131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3598541131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3598542131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3598543131010NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3598544131010NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3598545131010NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3598546131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3598547131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3598548131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3598549131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3598550131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3598551131010NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3598552131010NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3598553131010NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3598554131010NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3598555131010NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3598556131010NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3598557131010NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3598558131010NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3598559131010NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3598560131010NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3598561131010NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3598562131010NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3598563131010NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3598564131010NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3598565131010NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3598566131010NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3598567131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3598568131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3598569131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3598570131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3598571131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3598572131010NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3598573131010NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3598574131010NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3598575131010NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3598576131010NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3598577131010NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3598578131010NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3598579131010NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3598580131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3598581131010NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3598582131010NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3598583131010NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3598584131010NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3598585131010NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3598586131010NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3598587131010NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3598588131010NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3598589131010NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3598590131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3598591131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3598592131010NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3598593131010NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3598594131010NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3598595131010NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3598596131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3598597131010NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3598598131010NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3598599131010NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3598600131010NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3598601131010NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3598602131010NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3598603131010NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3598604131010NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3598605131010NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3598606131010NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3598607131010NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3598608131010NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3598609131010NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3598610131010NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3598611131010NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3598612131010NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3598613131010NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3598614131010NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3598615131010NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3598616131010NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3598617131010NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3598618131010NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3598619131010NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3598620131010NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3598621131010NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3598622131010NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3598623131010NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3598624131010NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3598625131010NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3598626131010NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3598627131010NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3598628131010NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3598629131010NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3598630131010NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3598631131010NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3598632131010NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3598633131010NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3598634131010NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3598635131010NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3598636131010NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3598637131010NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3598638131010NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3598639131010NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3598640131010NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3598641131010NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3598642131010NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3598643131010NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3598644131010NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3598645131010NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3598646131010NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3598647131010NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3598648131010NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3598649131010NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3598650131010NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3598651131010NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3598652131010NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3598653131010NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3598654131010NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3598655131010NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3598656131010NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3598657131010NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3598658131010NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3598659131010NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3598660131010NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3598661131010NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3598662131010NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3598663131010NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3598664131010NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3598665131010NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3598666131010NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3598667131010NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3598668131010NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3598669131010NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3598670131010NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3598671131010NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3598672131010NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3598673131010NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3598674131010NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3598675131010NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3598676131010NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3598677131010NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3598678131010NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3598679131010NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3598680131010NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3598681131010NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3598682131010NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3598683131010NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3598684131010NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3598685131010NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3598686131010NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3598687131010NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3598688131010NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3598689131010NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3598690131010NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3598691131010NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3598692131010NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3598693131010NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3598694131010NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3598695131010NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3598696131010NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3598697131010NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3598698131010NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3598699131010NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3598700131010NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3598701131010NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3598702131010NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3598703131010NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3598704131010NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3598705131010NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3598706131010NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3598707131010NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3598708131010NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3598709131010NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3598710131010NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3598711131010NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3598712131010NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3598713131010NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3598714131010NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3598715131010NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3598716131010NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3598717131010NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3598718131010NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3598719131010NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3598720131010NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3598721131010NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3598722131010NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3598723131010NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3598724131010NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3598725131010NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3598726131010NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3598727131010NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3598728131010NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3598729131010NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3598730131010NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3598731131010NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3598732131010NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3598733131010NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3598734131010NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3598735131010NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3598736131010NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3598737131010NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3598738131010NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3598739131010NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3598740131010NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3598741131010NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3598742131010NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3598743131010NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3598744131010NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3598745131010NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3598746131010NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3598747131010NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3598748131010NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3598749131010NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3598750131010NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3598751131010NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3598752131010NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3598753131010NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3598754131010NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3598755131010NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3598756131010NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3598757131010NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3598758131010NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3598759131010NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3598760131010NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3598761131010NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3598762131010NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3598763131010NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3598764131010NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3598765131010NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3598766131010NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3598767131010NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3598768131010NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3598769131010NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3598770131010NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3598771131010NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3598772131010NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3598773131010NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3598774131010NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3598775131010NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3598776131010NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3598777131010NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3598778131010NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3598779131010NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3598780131010NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3598781131010NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3598782131010NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3598783131010NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3598784131010NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3598785131010NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3598786131010NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3598787131010NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3598788131010NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3598789131010NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3598790131010NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3598791131010NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3598792131010NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3598793131010NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3598794131010NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3598795131010NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3598796131010NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3598797131010NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3598798131010NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3598799131010NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3598800131010NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3598801131010NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3598802131010NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3598803131010NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3598804131010NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3598805131010NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3598806131010NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3598807131010NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3598808131010NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3598809131010NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3598810131010NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3598811131010NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3598812131010NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3598813131010NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3598814131010NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3598815131010NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3598816131010NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3598817131010NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3598818131010NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3598819131010NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3598820131010NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3598821131010NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3598822131010NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3598823131010NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3598824131010NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3598825131010NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3598826131010NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3598827131010NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3598828131010NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3598829131010NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3598830131010NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3598831131010NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3598832131010NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3598833131010NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3598834131010NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3598835131010NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3598836131010NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3598837131010NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3598838131010NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3598839131010NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3598840131010NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3598841131010NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3598842131010NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3598843131010NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3598844131010NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3598845131010NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3598846131010NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3598847131010NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3598848131010NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3598849131010NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3598850131010NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3598851131010NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3598852131010NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3598853131010NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3598854131010NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3598855131010NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3598856131010NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3598857131010NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3598858131010NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3598859131010NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3598860131010NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3598861131010NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3598862131010NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3598863131010NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3598864131010NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3598865131010NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3598866131010NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3598867131010NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3598868131010NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3598869131010NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3598870131010NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3598871131010NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3598872131010NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3598873131010NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3598874131010NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3598875131010NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3598876131010NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3598877131010NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3598878131010NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3598879131010NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3598880131010NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3598881131010NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3598882131010NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3598883131010NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3598884131010NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3598885131010NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3598886131010NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3598887131010NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3598888131010NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3598889131010NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3598890131010NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3598891131010NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3598892131010NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3598893131010NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3598894131010NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3598895131010NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3598896131010NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3598897131010NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3598898131010NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3598899131010NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3598900131010NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3598901131010NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3598902131010NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3598903131010NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3598904131010NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3598905131010NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3598906131010NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3598907131010NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3598908131010NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3598909131010NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3598910131010NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3598911131010NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3598912131010NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3598913131010NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3598914131010NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3598915131010NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3598916131010NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3598917131010NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3598918131010NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3598919131010NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3598920131010NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3598921131010NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3598922131010NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3598923131010NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3598924131010NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3598925131010NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3598926131010NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3598927131010NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3598928131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3598929131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3598930131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3598931131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3598932131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3598933131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3598934131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3598935131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3598936131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3598937131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3598938131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3598939131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3598940131010NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3598941131010NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3598942131010NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3598943131010NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3598944131010NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3598945131010NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3598946131010NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3598947131010NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3598948131010NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3598949131010NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3598950131010NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3598951131010NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3598952131010NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3598953131010NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3598954131010NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3598955131010NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3598956131010NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3598957131010NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3598958131010NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3598959131010NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3598960131010NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3598961131010NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3598962131010NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3598963131010NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3598964131010NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3598965131010NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3598966131010NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3598967131010NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3598968131010NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3598969131010NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3598970131010NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3598971131010NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3598972131010NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3598973131010NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3598974131010NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3598975131010NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3598976131010NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3598977131010NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3598978131010NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3598979131010NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3598980131010NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3598981131010NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3598982131010NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3598983131010NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3598984131010NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3598985131010NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3598986131010NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3598987131010NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3598988131010NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3598989131010NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3598990131010NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3598991131010NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3598992131010NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3598993131010NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3598994131010NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3598995131010NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3598996131010NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3598997131010NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3598998131010NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3598999131010NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3599000131010NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3599001131010NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3599002131010NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3599003131010NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3599004131010NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3599005131010NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3599006131010NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3599007131010NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3599008131010NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3599009131010NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3599010131010NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3599011131010NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3599012131010NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3599013131010NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3599014131010NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3599015131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3599016131010NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3599017131010NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3599018131010NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3599019131010NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3599020131010NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3599021131010NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3599022131010NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3599023131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3599024131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3599025131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3599026131010NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3599027131010NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3599028131010NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3599029131010NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3599030131010NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3599031131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3599032131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3599033131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3599034131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3599035131010NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3599036131010NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3599037131010NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3599038131010NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3599039131010NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3599040131010NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3599041131010NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3599042131010NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3599043131010NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3599044131010NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3599045131010NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3599046131010NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3599047131010NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3599048131010NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3599049131010NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3599050131010NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3599051131010NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3599052131010NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3599053131010NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3599054131010NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3599055131010NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3599056131010NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3599057131010NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3599058131010NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3599059131010NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3599060131010NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3599061131010NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3599062131010NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3599063131010NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3599064131010NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3599065131010NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3599066131010NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3599067131010NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3599068131010NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3599069131010NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3599070131010NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3599071131010NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3599072131010NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3599073131010NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3599074131010NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3599075131010NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3599076131010NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3599077131010NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3599078131010NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3599079131010NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3599080131010NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3599081131010NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3599082131010NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3599083131010NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3599084131010NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3599085131010NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3599086131010NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3599087131010NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3599088131010NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3599089131010NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3599090131010NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3599091131010NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3599092131010NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3599093131010NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3599094131010NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3599095131010NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3599096131010NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3599097131010NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3599098131010NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3599099131010NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3599100131010NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3599101131010NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3599102131010NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3599103131010NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3599104131010NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3599105131010NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3599106131010NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3599107131010NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3599108131010NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3599109131010NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3599110131010NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3599111131010NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3599112131010NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3599113131010NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3599114131010NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3599115131010NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3599116131010NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3599117131010NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3599118131010Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218084240000NoneNoneBuildingsConstruction of primary health centre Metri in kampli taluk in Ballari district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3599119131011NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3599120131011NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3599121131011NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3599122131011NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3599123131011NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3599124131011NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3599125131011NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3599126131011NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3599127131011NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3599128131011NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3599129131011NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3599130131011NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3599131131011NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3599132131011NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3599133131011NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3599134131011NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3599135131011NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3599136131011NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3599137131011NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3599138131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3599139131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3599140131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3599141131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3599142131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3599143131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3599144131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3599145131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3599146131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3599147131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3599148131011NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3599149131011NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3599150131011NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3599151131011NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3599152131011NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3599153131011NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3599154131011NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3599155131011NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3599156131011NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3599157131011NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3599158131011NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3599159131011NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3599160131011NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3599161131011NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3599162131011NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3599163131011NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3599164131011NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3599165131011NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3599166131011NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3599167131011NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3599168131011NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3599169131011NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3599170131011NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3599171131011NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3599172131011NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3599173131011NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3599174131011NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3599175131011NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3599176131011NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3599177131011NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3599178131011NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3599179131011NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3599180131011NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3599181131011NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3599182131011NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3599183131011NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3599184131011NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3599185131011NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3599186131011NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3599187131011NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3599188131011NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3599189131011NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3599190131011NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3599191131011NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3599192131011NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3599193131011NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3599194131011NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3599195131011NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3599196131011NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3599197131011NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3599198131011NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3599199131011NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3599200131011NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3599201131011NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3599202131011NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3599203131011NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3599204131011NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3599205131011NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3599206131011NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3599207131011NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3599208131011NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3599209131011NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3599210131011NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3599211131011NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3599212131011NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3599213131011NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3599214131011NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3599215131011NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3599216131011NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3599217131011NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3599218131011NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3599219131011NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3599220131011NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3599221131011NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3599222131011NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3599223131011NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3599224131011NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3599225131011NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3599226131011NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3599227131011NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3599228131011NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3599229131011NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3599230131011NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3599231131011NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3599232131011NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3599233131011NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3599234131011NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3599235131011NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3599236131011NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3599237131011NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3599238131011NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3599239131011NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3599240131011NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3599241131011NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3599242131011NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3599243131011NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3599244131011NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3599245131011NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3599246131011NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3599247131011NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3599248131011NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3599249131011NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3599250131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3599251131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3599252131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3599253131011NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3599254131011NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3599255131011NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3599256131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3599257131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3599258131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3599259131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3599260131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3599261131011NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3599262131011NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3599263131011NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3599264131011NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3599265131011NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3599266131011NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3599267131011NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3599268131011NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3599269131011NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3599270131011NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3599271131011NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3599272131011NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3599273131011NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3599274131011NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3599275131011NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3599276131011NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3599277131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3599278131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3599279131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3599280131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3599281131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3599282131011NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3599283131011NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3599284131011NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3599285131011NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3599286131011NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3599287131011NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3599288131011NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3599289131011NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3599290131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3599291131011NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3599292131011NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3599293131011NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3599294131011NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3599295131011NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3599296131011NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3599297131011NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3599298131011NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3599299131011NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3599300131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3599301131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3599302131011NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3599303131011NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3599304131011NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3599305131011NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3599306131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3599307131011NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3599308131011NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3599309131011NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3599310131011NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3599311131011NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3599312131011NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3599313131011NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3599314131011NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3599315131011NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3599316131011NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3599317131011NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3599318131011NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3599319131011NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3599320131011NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3599321131011NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3599322131011NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3599323131011NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3599324131011NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3599325131011NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3599326131011NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3599327131011NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3599328131011NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3599329131011NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3599330131011NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3599331131011NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3599332131011NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3599333131011NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3599334131011NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3599335131011NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3599336131011NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3599337131011NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3599338131011NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3599339131011NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3599340131011NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3599341131011NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3599342131011NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3599343131011NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3599344131011NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3599345131011NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3599346131011NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3599347131011NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3599348131011NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3599349131011NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3599350131011NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3599351131011NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3599352131011NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3599353131011NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3599354131011NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3599355131011NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3599356131011NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3599357131011NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3599358131011NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3599359131011NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3599360131011NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3599361131011NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3599362131011NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3599363131011NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3599364131011NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3599365131011NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3599366131011NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3599367131011NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3599368131011NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3599369131011NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3599370131011NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3599371131011NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3599372131011NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3599373131011NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3599374131011NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3599375131011NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3599376131011NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3599377131011NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3599378131011NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3599379131011NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3599380131011NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3599381131011NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3599382131011NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3599383131011NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3599384131011NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3599385131011NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3599386131011NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3599387131011NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3599388131011NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3599389131011NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3599390131011NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3599391131011NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3599392131011NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3599393131011NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3599394131011NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3599395131011NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3599396131011NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3599397131011NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3599398131011NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3599399131011NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3599400131011NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3599401131011NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3599402131011NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3599403131011NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3599404131011NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3599405131011NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3599406131011NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3599407131011NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3599408131011NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3599409131011NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3599410131011NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3599411131011NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3599412131011NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3599413131011NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3599414131011NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3599415131011NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3599416131011NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3599417131011NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3599418131011NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3599419131011NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3599420131011NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3599421131011NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3599422131011NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3599423131011NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3599424131011NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3599425131011NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3599426131011NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3599427131011NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3599428131011NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3599429131011NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3599430131011NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3599431131011NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3599432131011NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3599433131011NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3599434131011NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3599435131011NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3599436131011NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3599437131011NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3599438131011NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3599439131011NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3599440131011NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3599441131011NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3599442131011NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3599443131011NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3599444131011NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3599445131011NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3599446131011NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3599447131011NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3599448131011NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3599449131011NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3599450131011NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3599451131011NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3599452131011NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3599453131011NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3599454131011NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3599455131011NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3599456131011NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3599457131011NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3599458131011NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3599459131011NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3599460131011NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3599461131011NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3599462131011NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3599463131011NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3599464131011NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3599465131011NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3599466131011NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3599467131011NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3599468131011NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3599469131011NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3599470131011NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3599471131011NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3599472131011NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3599473131011NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3599474131011NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3599475131011NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3599476131011NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3599477131011NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3599478131011NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3599479131011NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3599480131011NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3599481131011NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3599482131011NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3599483131011NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3599484131011NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3599485131011NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3599486131011NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3599487131011NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3599488131011NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3599489131011NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3599490131011NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3599491131011NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3599492131011NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3599493131011NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3599494131011NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3599495131011NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3599496131011NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3599497131011NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3599498131011NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3599499131011NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3599500131011NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3599501131011NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3599502131011NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3599503131011NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3599504131011NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3599505131011NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3599506131011NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3599507131011NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3599508131011NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3599509131011NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3599510131011NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3599511131011NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3599512131011NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3599513131011NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3599514131011NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3599515131011NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3599516131011NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3599517131011NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3599518131011NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3599519131011NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3599520131011NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3599521131011NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3599522131011NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3599523131011NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3599524131011NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3599525131011NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3599526131011NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3599527131011NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3599528131011NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3599529131011NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3599530131011NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3599531131011NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3599532131011NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3599533131011NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3599534131011NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3599535131011NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3599536131011NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3599537131011NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3599538131011NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3599539131011NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3599540131011NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3599541131011NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3599542131011NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3599543131011NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3599544131011NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3599545131011NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3599546131011NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3599547131011NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3599548131011NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3599549131011NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3599550131011NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3599551131011NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3599552131011NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3599553131011NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3599554131011NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3599555131011NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3599556131011NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3599557131011NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3599558131011NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3599559131011NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3599560131011NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3599561131011NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3599562131011NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3599563131011NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3599564131011NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3599565131011NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3599566131011NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3599567131011NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3599568131011NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3599569131011NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3599570131011NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3599571131011NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3599572131011NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3599573131011NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3599574131011NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3599575131011NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3599576131011NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3599577131011NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3599578131011NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3599579131011NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3599580131011NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3599581131011NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3599582131011NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3599583131011NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3599584131011NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3599585131011NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3599586131011NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3599587131011NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3599588131011NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3599589131011NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3599590131011NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3599591131011NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3599592131011NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3599593131011NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3599594131011NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3599595131011NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3599596131011NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3599597131011NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3599598131011NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3599599131011NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3599600131011NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3599601131011NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3599602131011NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3599603131011NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3599604131011NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3599605131011NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3599606131011NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3599607131011NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3599608131011NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3599609131011NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3599610131011NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3599611131011NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3599612131011NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3599613131011NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3599614131011NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3599615131011NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3599616131011NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3599617131011NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3599618131011NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3599619131011NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3599620131011NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3599621131011NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3599622131011NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3599623131011NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3599624131011NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3599625131011NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3599626131011NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3599627131011NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3599628131011NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3599629131011NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3599630131011NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3599631131011NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3599632131011NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3599633131011NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3599634131011NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3599635131011NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3599636131011NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3599637131011NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3599638131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3599639131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3599640131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3599641131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3599642131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3599643131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3599644131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3599645131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3599646131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3599647131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3599648131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3599649131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3599650131011NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3599651131011NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3599652131011NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3599653131011NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3599654131011NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3599655131011NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3599656131011NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3599657131011NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3599658131011NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3599659131011NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3599660131011NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3599661131011NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3599662131011NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3599663131011NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3599664131011NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3599665131011NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3599666131011NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3599667131011NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3599668131011NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3599669131011NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3599670131011NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3599671131011NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3599672131011NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3599673131011NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3599674131011NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3599675131011NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3599676131011NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3599677131011NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3599678131011NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3599679131011NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3599680131011NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3599681131011NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3599682131011NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3599683131011NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3599684131011NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3599685131011NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3599686131011NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3599687131011NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3599688131011NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3599689131011NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3599690131011NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3599691131011NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3599692131011NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3599693131011NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3599694131011NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3599695131011NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3599696131011NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3599697131011NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3599698131011NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3599699131011NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3599700131011NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3599701131011NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3599702131011NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3599703131011NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3599704131011NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3599705131011NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3599706131011NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3599707131011NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3599708131011NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3599709131011NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3599710131011NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3599711131011NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3599712131011NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3599713131011NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3599714131011NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3599715131011NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3599716131011NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3599717131011NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3599718131011NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3599719131011NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3599720131011NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3599721131011NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3599722131011NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3599723131011NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3599724131011NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3599725131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3599726131011NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3599727131011NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3599728131011NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3599729131011NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3599730131011NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3599731131011NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3599732131011NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3599733131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3599734131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3599735131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3599736131011NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3599737131011NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3599738131011NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3599739131011NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3599740131011NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3599741131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3599742131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3599743131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3599744131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3599745131011NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3599746131011NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3599747131011NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3599748131011NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3599749131011NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3599750131011NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3599751131011NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3599752131011NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3599753131011NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3599754131011NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3599755131011NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3599756131011NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3599757131011NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3599758131011NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3599759131011NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3599760131011NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3599761131011NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3599762131011NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3599763131011NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3599764131011NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3599765131011NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3599766131011NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3599767131011NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3599768131011NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3599769131011NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3599770131011NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3599771131011NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3599772131011NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3599773131011NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3599774131011NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3599775131011NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3599776131011NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3599777131011NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3599778131011NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3599779131011NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3599780131011NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3599781131011NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3599782131011NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3599783131011NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3599784131011NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3599785131011NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3599786131011NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3599787131011NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3599788131011NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3599789131011NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3599790131011NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3599791131011NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3599792131011NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3599793131011NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3599794131011NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3599795131011NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3599796131011NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3599797131011NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3599798131011NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3599799131011NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3599800131011NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3599801131011NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3599802131011NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3599803131011NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3599804131011NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3599805131011NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3599806131011NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3599807131011NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3599808131011NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3599809131011NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3599810131011NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3599811131011NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3599812131011NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3599813131011NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3599814131011NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3599815131011NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3599816131011NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3599817131011NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3599818131011NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3599819131011NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3599820131011NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3599821131011NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3599822131011NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3599823131011NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3599824131011NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3599825131011NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3599826131011NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3599827131011NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3599828131011Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218084320000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218084320000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218084320000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17218084320000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218084320000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218084500000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17218084670000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17218084770000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17218084840000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17218084890000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17218084960000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17218085010000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17218085060000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17218085140000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17218085200000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17218085260000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17218085320000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17218085380000NoneNoneELIGIBILITYMaterials like, steel(primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17218085430000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17218085500000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17218085560000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17218085620000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17218085690000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17218085770000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17218085820000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.1402.20 LakhPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.350.55 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works 1. Earthwork Excavation in all kinds of soil 2450.00 Cum 2.PCC & RCC 12808.00 Cum 3. Steel Reinforcement for RCC work (TMT Steel) 77.73 Tonne 4.BBM/Concrete Blocks 536.00 Cum. 5. Plastering 7053.00 Sqm 6. Painting (OBD/Textured Painting/Wood and Metal Painting) 10863.00 Sqm 7. Flooring (Vitrified/Granite/Ceramic) 1634.00 Sqm 8. MS Grill 2286.00 Kgs Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d The tenderer or his identified sub contractor should possess required valid electrical license issued by KPWD,Government electrical Inspectorate for executing building electrification works and should have executed similar Building electrical works totaling to Rs.55.99 Lakh in any one year Note.The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government,Semi Government,Government undertaking,autonomous bodies of Government will be considered, for the clause 3.2d.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e):The Tenderer or his identified sub-contractor should possess valid license issued by BWSSB/KUWS&DB for executing water supply/sanitary engineering works and should have executed similar building water supply/sanitary engineering works totaling to Rs.12.68 Lakhs in any one year Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass - I PWD Registered Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.3(a) Equipment capacity: Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50%can be deployed on ease/hire basis for all works provided,the relevant documents (commitment agreements etc) for availability for this work are furnished SlNo. Description of Key items of Works. Quantity1. Excavator/JCB 1No 2. Transit Mixer/Concrete Mixer 1 No 3. Needle vibrator with size not less than 20mm 1 No 4.Tipper 1 No 5.Generator 250 KVA 1 No 6. Truck Mounted Water Tanker 1 No Note: All Machineries purchased during last five years only should be used and will be considered for evaluation.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneClause ITT 3.6 Tenderers who meet the above specified minimum qualifying criteria,will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2019-20-2023-24)(updated to 2024-25 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2024-25 price level, of existing commitments of and ongoing works to be Completed during the next 11 months.Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1) Site Engineer (Civil) B.E. Civil with minimum experience of 7 years in the Construction of buildings 1 (One) 2) Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.280.44 Lakh (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
ESI & PF CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721809108000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone